Home

H30 User Manual

image

Contents

1. SAVE Tuning Save datalog Zoom OFF 1 274 3 4th Select a quadrant of the constellation to be represented for more detailed view Select Zoom OFF for the full constellation Parameters Bandwidth Auto 6 MHz 7MHz 8MHz Symbol Rate Auto 6111 5156 Other Constellation Auto 4QAM 16QAM 32QAM 64QAM 128QAM 256QAM Standard ITU J 83 A J 83 B J 83 C DFE OFF ON Tuning Channel Frequency Save datalog Saves the current scan measurements You can see the datalogs using the remote control application 6 CTB amp CSO Cable TV networks are generally located in densely populated areas or extend over large geographical regions This makes cascading large numbers of amplifiers a frequent necessity that can be the cause of quality of service to drop below minimum acceptable levels Composite second order CSO and composite triple beat CTB are commonly used quality parameters that can be measured with the H30 to ensure the best possible quality video for customers receiving analog signals In order to get an accurate measurement of CTB and CSO the meter must be tuned to an analog channel with unmodulated video and audio carriers Many operators will choose to leave an unmodulated channel on the system to allow for this measurement at any time without affecting customers 6 1 Main window Below is a capture of a CTB CSO window with a brief explanation of its features
2. leleves CATV Meter Analyzer Instruction Manual Televes Index Safety requirements iaa 4 SVEIO ees E E R EER E 5 Key Feats OA PP o een nee ANEAN ANNER ee 5 General specifications u a end Eee 6 Technical specifications scene anna aaa T7 Description of equipment components ccocccccncnccnnnoncnnnnnonnncnnnnnnnnnnnnnananonanoss 8 Connectors and COMIrOlS vincia dede 8 An 8 POWER SUDOR prada cada added 9 Product OPTION asentar started ia lies 10 ei WENO ee E 10 WAE ACA anoto 10 A E RI santana cee 11 2 nenne E 12 He o nenn dee 13 A GI aa 13 a ii a EAR 14 EOU a E E E 15 ESER a E A A EE A EA E T E E A 15 A SCAN ae RAAE N E EE 16 OC PA CE O PEE EA 17 A O 17 PULL A a ne EI A aaenadacinaeddoneds 18 ENMemet Features civic sodio 19 NEIWOIK ID apura oa 19 FITAWate Upadle sureste edit UF EEREESEREEEREURLEIEBPEENSEREEER 19 Remote COOL nora ro rita 20 A A 23 Technical SUDDOTE une ia iia 23 E eE no E E T 24 m 7 L O Z M H30 CATV Meter Analyzer Safety requirements o Product inspection Inspect the equipment for shipping damage Should any damage be discovered immediately file a claim with the carrier Read and Follow All Instructions All the safety and operating instructions should be read prior to and followed while operating this product o Cleaning Follow the cleaning instructions contained in the Maintenance section of this manual Attachments Do not us
3. 11 47AM CH 117 751 25 MHz CH 133 849 00 MHz GQOTilt dB 19 20 Bar graph representing all the channels Color according to checkmarks 3 2 Setup un Press sere to change the Tilt options Tilt Setup 11 03PM Ma Selected channel Span Ref level 36dBuV E Change using User can change it using Filter channels Level aes A J 4 or OK Plan CUSTOM3 Yeas BACK Save datalog 01 49AM Mal 0 CH 60 786 0000 MHz Ref Level Select the reference level of the Pwr dBmV bar graph air Filter channels Level None Oc N dB User can choose to filter the channels that 38 9 dont comply a minimum level i AL LI Lal Plan FCC STD FCC RETURN FCC IRC FCC HRC FCC OFFAIR CCIR Custom plans List of Save datalog Saves the current scan measurements Reference level measurements You can see the datalogs with pass fail Auto using the remote control application indicators 4 2 Setup Pd Press sere to change Spectrum options E 4 Spectrum Spectrum Setup Real time processing speeds ensure capture of any fast intermittent plant impairments dB div 10dB div Due to the accuracy and level of detail provided by this spectrum analyzer the H30 is the ideal tool for identifying and locating noise interference ingress and other waveforms that may be affecting cable services quality Tuning Channel A D Digital Save datalog SAVE 4 1 Main window Span 2 5MHz
4. CH73 CH124 519 000MHz 795 000MHz O POWER 9 9 dBmv O POWER 3 0 dBmv O CN gt 50 0 dB OCN 250 0 dB Over 36 5 dB Omer 38 1 dB CBER lt 1 0E 6 OcBER lt 1 0E8 Apply filter Icons view Maintenance Always disconnect the unit before cleaning Use only a mild solution of detergent and water applied with a soft damp cloth Dry thoroughly before use Do not use aromatic hydrocarbons or chlorinated solvents These products may damage the unit Do not use alcohol or alcohol based products on the front panel especially the display These products may damage the unit Technical support For any questions contact Technical Support at www televes usa com Before contacting Technical Support for repair read the manual to ensure proper use and attempt to RESET the unit to clear any problems Repair service Do not return the unit without first contacting Televes Technical Support If the unit needs to be returned Televes will arrange for free shipping The unit will need to be appropriately packed for shipping In compliance with IATA Regulations when using our shipping service follow these instructions Label the package gt The equipment should fit as snugly as possible in the box It is recommended to use the original packing materials gt Attach the precaution label to the package J ILLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLG CAUTION O Lo Lithium ion battery IF DAMAG
5. volcano excessive heat or cold lightning flood power surge earthquake or any other acts of God VI war crime strike riot electro magnetic pulse or any other acts beyond the control of Televes VII shipping D All claims under the terms of this warranty must be made in writing by the original Purchaser within fourteen 14 days of the defect being known to the Purchaser Such claims shall be accompanied by a description of any material facts related to the claimed defect and the invoice or other proof of original purchase date and price If Televes so requests the Purchaser shall at Purchaser s expense deliver the claimed Product s to Televes within 14 days of the date of the return authorization Under no circumstances shall the Product s be returned to Televes without a return authorization the purchase price of the Product s excluding any applicable taxes duties freight costs removal costs installation costs or any other charges incident to the purchase of the product F Any damage caused by shipper shall be claimed with the shipper in accordance with the shipper s policies and procedures G Televes shall in no event and under no circumstances be liable or responsible for any consequential indirect incidental punitive direct or special damages based upon breach of warranty breach of contract negligence strict tort liability or otherwise or any other legal theory arising dire
6. 6 25MHz 12 5MHz 25MHz Below is a capture of a Spectrum window with a 62 5MHz 125MHz 250MHz 500MHz Full brief explanation of its features Set the span of the spectrum To easily change the span use the OK Button to decrease the span and the Back Button to increase the span dB div 5 dB div 10 dB div Tuning Channel Frequency A D Auto Analog Digital Save datalog Saves the current scan measurements You can see the datalogs using the remote control application 5 Constellation video often does not Digital impairment until it is too late due to the small margin between acceptable quality and failure show signal Constellation diagrams are an indispensable tool to help detect the presence of noise phase jitter interference and gain compression all of which impact overall signal quality and thus reduce Modulation Error Ratio MER Ideally each of the symbols in a constellation diagram should display a clean dot indicating a perfect QAM signal The H30 s real time constellation allows the installer to assess the size and shape of the build up of dots indicative of problems which contribute to bit errors leading to service disruption 5 1 Main window Below is a capture of a Constellation window with a brief explanation of its features OS MT AM oa 01 56AM CH 60 ppogggagi 5 2 Setup Press to change Constellation options Setup Parameters Channel
7. Selected channel Change using gan Channel plan er CUSTOM3 11 00PM MN CH 45 663 2500 MHz 10 0 dBmv gt 54 0 dBc gt 54 0 8 O Video O CTB cso Bar graphs of List of measurements the CTB and CSO with pass fail indicators measurements Color according to checkmarks 6 2 Setup y Press serve to change CTB amp CSO options CTB CSO Setup 10 48PM MN Tuning Channel k CSO Offsets Save datalog Tuning Channel Frequency CSO offsets The CSO measure is carried out in different frequencies at a variable range from the video carrier within the selected channel This allows setting these frequencies in kHz from the video carrier Save datalog Saves the current scan measurements You can see the datalogs using the remote control application 7 Voltmeter amp Hum H30 measures the voltage present at the RF input The HUM measurement indicates the variation in percentage of the video carrier amplitude of the TV signal This will help you diagnose those ground and power interference problems that may result from a defective power supply or faulty overloaded power inserters 7 1 Main window Below is a capture of a Voltmeter amp Hum window with a brief explanation of its features Selected channel Change using is Channel plan a 04 30AM MN E 789 0000 MHz Volt 89 5 pc lt 1 0 Hum Bar graph
8. dB CSO CTB Y Channel Plans Factory channel Standard CATV Return HRC IRC plans Broadcast CCIR Automatic and manual reference Y level Reverse Path Ingress Scan Custom channel plans learning plan Up to 16 channel plans Selectable 5 to 42MHz 5 to Bange 68MHz and 5 to 85MHz Peak Average Min and Real Mode time Digital Measurements ITU T J 83 Annex A B C standard 16 32 64 128 and 256 QAM Demodulation System Scan Up to 100 channels analog and Channels or digital Measurements Level bar representation and C N BER MER of the selected channel Tilt channels Up to 100 channels analog and Selectable markers or digital Y Pass Fail Indicators Factory profiles Trunk Tap End of line Ground Block Modem Setup Custom profiles up to 10 profiles Support OPSK Symbol Rate 2 to 6 9 MS sec QAL Technology Ch teristics and modulation QAM Auto Lock parameters DFE filter On Off C N Up to 45 dB MER Up to 40 dB Accuracy 2 dB Resolution 0 1 dB Pre BER and Post BER Annex B 1 0E 3 to 1 0E 8 BER Annex A C 1 0E 3 to 1 0E 8 Constellation Display 16 32 64 128 and 256 QAM Zoom Capability Y Voltmeter Range 9V to 150V Accuracy 1 Hum Range 2 to 5 Accuracy 1 Speed Test Option 593211 ea Up to 20Mbps Ping times Y Service Info Option 593210 Channel Equaliz
9. fully charged the battery icon is completely filled As the battery discharges the amount the icon is filled decreases in steps The icon shows 5 states approximate battery charge representing the Battery charge less than 5 Hj Battery charge between 5 and 25 Battery charge between 25 and 50 MI Battery charge between 50 and 75 Ch Battery charge greater than 75 From a fully discharged state a full charge takes approximately 8 hours and a 3 hour charge will provide approximately a 75 charge The charge management system will detect various conditions preventing charging such as a battery that is over a safe temperature Battery Recommendations To maximize battery life Avoid fully discharging the battery gt The battery should always be charged with the battery pack attached to the device and using the supplied DC adapter or applying a constant voltage within the specified range 12 15VDC gt For long term storage keep the unit at room temperature or about 25 C Start with a charged battery and re charge the battery every 2 to 3 months H30 CATV Meter Analyzer Product operation i 1 Channel Info Analog and digital channels are very different in terms of signal content and power distribution and thus require the advanced SLM techniques provided in the Televes H30 In analog mode video and audio levels V A and Carrier to Noise C N are measured
10. improve decision making Control your H30 remotely and make measurements from any internet connected device Ideal for extended signal tests over time in headends and broadband distribution networks Leave your H30 connected to your headend or anywhere in your plant and control the unit and measure signals and quality parameters remotely Once finished export the results to your computer using the included Remote Application software H30 CATV Meter Analyzer General Specification 2 8 TFT 400 x 240 full color 1 12 Ib 510 9 6 9 x 3 9x2in 175x 100x52 mm HxWxD Input 100 240V 50 60Hz Output 12VDC 2A Lilon smart battery 7 2VDC 2300mAh gt 5 hours 23 F to 104 F 5 C to 45 C 4 F to 158 F 20 C to 70 C 5 to 95 non condensing Survives 1 m 3 ft drop to concrete on all sides USB 2 0 RJ45 10 100 T Ethernet interface for Remote Control Measurements Datalog Retrieval and Automatic Software Updates 400 MB internal for measurements lt 10 seconds Technical Specifications Analog Measurements Frequency Range 5 MHz to 1002 MHz Resolution 50 kHz Tuning Frequency or channel Input Impedance 750 F type connector Spectrum Analyzer 2 5 6 25 12 5 25 62 5 125 250 500 MHz and Full Scale 5 and 10 dB div Level measurement 30 to 60 dBmV V A up to 30 dB C N up to 45 dB Accuracy 2 dB Resolution 0 1
11. main configuration settings me Setup 10 02AM MN Units dBmV Quality profile End Line Plan FCC STD Network Time and Date Language English Espanol Units dBuV dBmV dBm Quality profiles Trunk Tap End Line Ground Differentthresholds are available for different testing locations Plan FCC STD FCC RETURN FCC IRC FCC HRC FCC OFFAIR CCIR and customers plans saved using Learning Plan Network IP Auto Manual Network Info IP Gateway DNS IP Auto sets the IP default gateway and DNS automatically Results are shown in Network info section Man IP When Manual IP is selected the user must set the IP Man GW When Manual IP is selected the user must set the gateway Man DNS When Manual IP is selected the user must set the DNS Time and Date Set current time hour and minutes and date day of the month month and year Update firmware ON OFF When ON every time the H30 is connected to the internet it will allow the user to update the firmware if a new version is available Televes Set the network parameters in the H30 to use the IP 192 168 10 41 Ethernet port Gateway 192 168 10 249 DNS 8 8 8 8 1 Network setup To configure Internet access select the function Setup from the main menu 01 35PM MM A 2 Firmware update Constellation CTB amp CSO Voltmeter amp Hum Following are details to update the firmware of Equalize
12. ED DO NOT LOAD OR TRANSPORT PACKAGE IF DAMAGED For more information call 0034 981 52 22 00 NNNNAAAANAAAANAAAAANRAAAAARAAAAAAA OOOO OOO ONO OOOO OOOO OOO OOOO OOO OOOO CIO OI OIC VLLLLLLLILLLLLLLLLLL Ltt Failure to comply with these shipping requirements may result in the shipping agent rejecting the package H30 CATV Meter Analyzer Warranty A Televes warrants only to the original Purchaser all Products be free from any defect in materials E Any refund to the Purchaser shall be limited to or workmanship for a period of one 1 year six 6 months for the battery from the date of original purchase unless otherwise specified B Televes shall free of charge and in its sole discretion either repair replace with a new or factory reconditioned equivalent or refund the purchase price of the Product s that has been determined by Televes to be defective in material or workmanship subject to the limits of this warranty C This warranty excludes any inoperability resulting from use or installation that is not in strict compliance with the written instructions and specifications II any modification or alteration performed by any third party not authorized in writing by Televes Ill service or repair performed by any third party not authorized in writing by Televes IV misuse abuse intentional harm or lack of reasonable care V fire ice snow rain wind water
13. In digital mode it s Power C N Pre BER and Post BER 1 1 Main window Below is a capture of a Channel Info window with a brief explanation of its features Charsel In o CH 60 01 52AM Mar 1 2 Setup Press to change the Channel Info options Channel Info Setup 07 39PM MN A D Digital Parameters SAVE Save datalog Tuning Channel Frequency A D Auto Analog Digital Parameters Bandwidth Auto 6 MHz 7MHz 8MHz Symbol Rate Auto 6111 5156 Other Constellation Auto 40AM 16QAM 320AM 640AM 1280AM 2560AM Standard ITU J 83 A J 83 B J 83 C DFE OFF ON Save datalog Saves the current measurements You can see the datalogs using the remote control application ni 2 System Scan This function scans the selected channel plan and detects every existing analog and digital channel in real time to determine the overall frequency response of the system The scan measurement leverages the location based thresholds to clearly show whether or not signal levels comply with the cable system s specifications with their green yellow and red bars This gives an easy to understand real time view of the system including the BER and MER values of the selected channel 2 1 Main window Below is a capture of a System Scan window with a brief explanation of its features Channel EN Measurements ange using Channel of the selected ALLA Frequency plan chan
14. ading new files Google Chrome or Safari is recommended Open your browser in your PC or in your tablet Configure your network parameters see section 1 Network setup 130 i 6 When the installation is complete press the OK button to reboot the meter To run the remote control application you must copy the IP in the web browser bar and Note When your H30 connects to the server to automatically will appear the main window of the update the firmware it checks in our database ifyou application have purchased any of the available options If so they will be activated automatically with the update IP Auto 4 Welcome IP Manual Ip 192 168 10 41 Gateway 192 168 DNS Setup Network IP Network Info Man IP 192 168 010 101 Man GW 192 168 010 249 Man DNS 008 008 008 008 Manual o The following functions are available in the remote control application Channel Info Sets the H30 in Channel Info mode and shows the current Channel Info main window Select other channel from the plan CH60 786 0000 MHz Power CUSTOM1 OMER 36 2 dB OCBER lt 1 0E 8 Go back to the main window Channel Info 9 0 dBmv Oc N 41 3 dB fo Spectrum Select other channel from the plan CH48 687 2500 MHz Lev dBmV V A dB gt 30 0 Oc N dB 45 8 Span 12 5MHz CUSTOM1 Log Out Datalogs List of Datalogs Spectrum O T
15. ctly or indirectly from the sale use installation or failure of any product acquired by Purchaser from Televes H This limited warranty extends to the original Purchaser and cannot be assigned or transferred to any other party without the prior express written permission of Televes which permission Televes may withhold for any reason or for no reason at all I Televes will not assume any liabilities for any other warranties whether statutory express or implied made by any other person J Televes reserves the right to modify or discontinue this warranty at Televes sole discretion without notification No other warrantees are expressed or implied H30 CATV Meter Analyzer DECLARATION OF CONFORMITY N 130307110243 Per FCC Part 2 Section 2 1077 a Responsible Party Name Televes S A Address Rua Ben fica de Conxo 17 15706 Santiago de Compostela Spain Phone Fax N 981522200 981522262 a y Hereby declares that the product Product Name H30 Model Number 593101 Conforms to the following specifications FCC Part 15 Subpart B Section 15 107 e and section 15 109 g Bs Supplementary Information This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Represen
16. e attachments that are not approved by the product manufacturer o Water and Moisture This product is weather resistant but is not submersible Power Sources This product should be operated only from the type of power source specified Grounding or Polarization Do not bypass or defeat electrical plug polarization or grounding Doing so will violate the warranty and may pose a risk of fire or electrocution o Wire Protection Ensure all connected wiring is routed correctly to avoid damage including pinching excessive bends or compression O Electrical Supply Grounding and Surge Protection Ensure that all local or national electrical codes are followed Power Lines Always use caution and avoid operating t or any connected equipment near unins power lines or any other hazards o Servicing There are no user serviceable parts except the battery Do not attempt to service this product or remove covers other than the battery cover Refer all servicing to qualified service personnel Follow the instructions in this manual when replacing the battery Heat The product should be situated away from heat sources such as radiators heat registers stoves or other products including amplifiers that produce heat Overview Introducing the H30 New from Televes a go to meter designed with the needs of a Cable TV operator in mind The H30 is a light weight rugged unit packed with a
17. e control application in 9 Learning plan Analyzes the input signal to the meter and automatically detects all channels This feature automatically identifies the channels as either analog or digital and performs measurements on each A bar graph is displayed with the height representing the power for digital channels and the level of the video carrier for the analog channels The measurements made for analog channels are video carrier level and V A For digital channels the measurements are power and C N The analog channels will have an extra smaller white bar indicating the level of the audio carrier 9 1 Main window Below is a capture of a Learning Plan window with a brief explanation of its features Selected channel Change using List of measurements ss with pass fail indicators k Vom pr ing Plan FCC STD 10 09AM CH 69 858 0000 MHz 1 8 dBmv 37 0 dB Power O C N Indicates that the scan is finished Press to save the plan Bar graph representing found channels Color according to checkmarks 10 Ingress Scan Help identify reverse path problems before your customers are affected Poorly shielded coaxial cable and faulty terminations are important sources of ingress noise which can easily add up in the return due to the large number of subscriber generated signals that are sent back to the headend The combined and amplified interference is often responsible for service di
18. eleves Sets the H30 in Spectrum mode and shows the current Spectrum main window Go back to the main window ww Log out the current session from the H30 In this section you can see all the measures saved in your H30 with the Save Datalog feature Go back to the main window ILOG_01 01 00_022007AM ILOG_01 01 00_022029AM ILOG_ 01 01 00 022140AM ILOG_01 01 00 024914AM ILOG_01 01 00 030049AM ILOG_01 01 00_032544AM ILOG_01 01 00_032546AM ILOG_01 01 00_032549AM ILOG_01 01 00_032602AM User can add a description for each datalog Press Edit button of the selected Datalog Enter the description and press Change User can also delete a log from the list by pressing Del button Press Delete to confirm ILOG_01 01 00_022140AM xmi Are you sure you want to delete this item Selecting a Datalog shows a list of all the channels of the selected datalog with its corresponding measurements and pass fail indicators Two views Table view Back to the list of and Icon view Datalogs Icons View Table View Apply filter CH73 519 000MHz 9 90BmV gt 50 0 CH124 795 000MHz 3008mY gt 500 Pass D Warning m Fail Filter results with quality indicators There are two views for the list of channels Table view and Icons View Above is shown the Table View and below the Icons View Datalog Datalogs
19. er Graphical v representation Specifications are subject to change without notice Channel parameters Service parameters NIT PAT TSID CBRT SID VID AID bitrate encode type H30 CATV Meter Analyzer Description of equipment Keyboard components Connectors and controls Device On Off button To turn the equipment off press and hold for approximately 3 seconds 2 a Back button Return to the previous menu or close a parameter entry window 1 External power connector 12VDO 3 Home button Return to the main menu 2 LCD display 3 Keyboard and LED indicators 4 Rotating selector Used to scroll through 4 RF F connector see options below u Options 5 Reset 5 ok OK Button To confirm selection 6 Ethernet connector 6 Setup button Parameter window for the F connector options e eae 7 LED Load Indicates if the equipment is powering an external load 8 LED Charging Battery Indicates if the battery is charging 9 LED Power ON Illuminated when the equipment is on Power supply A DC adapter is provided to power and charge the meter Plug the adapter into a properly grounded electrical supply and the power connector on the side of the unit l When external power is supplied the battery management system automatically controls the charging process A battery icon indicates the charge status of the battery When the battery is
20. ll the features needed to install and troubleshoot a television system using QAM digital modulation as well as NTSC analog signals This handy little unit is even inexpensive enough to leave in your headend and use its unique in its class remote measurement and control capabilities to provide long term monitoring or to troubleshoot those hard to find intermittent problems Available for the first time in such a portable and affordable package its real time digital processing engine gives the installers the lab precision measurements needed in today s fulfilment environment Key Features o User friendly handheld QAM meter Remote measurements and control in an affordable package Complete measurements indicators portfolio of Analog Digital with easy to read pass fail Quick and easy to use interface with features such as Channel measurements System Scans Tilt Function Constellation Diagram Spectrum Analyzer Voltmeter Hum Service Identification option 593210 Datalogger and more Rugged light weight fully automatic fast and accurate Automatic through the cloud software updates o 100 automatic ITU T J 83 Annex A B C parameter detection and measurement with no setup needed 1 GHz spectrum range with selectable span PASS FAIL Indicators Icons indicate if a measurement is good bad or in the warning zone for quick and easy status checks Reduce installer entry errors and
21. nel 5 with pass fail TA indicators 34 8 lt 1 0E 8 MER 789 0000 MHz CBER i sili a 27 61 132 15dB div Ref 30dByuV Bar graph representing all the found channels Color according to checkmarks 2 2 Setup Press sere to change the System Scan options System Scan 12 49PM 7 Setup Ref level 30dBmV KK Level CUSTOM3 Filter channels Plan Save datalog Ref Level Select the reference level of the bar graph Filter channels Level None User can choose to filter the channels that don t meet a minimum level Plan FCC STD FCC RETURN FCC IRC FCC HRC FCC OFFAIR CCIR Custom plans Save datalog Saves the current scan measurements You can see the datalogs using the remote control application Televes Dan anit 3 Tilt Any number of analog digital or DOCSIS channels can be measured using the tilt measurement and you can even select which carriers are your reference points to determine the tilt between any of the channels included in the measurement The Tilt measurement leverages the location based thresholds to clearly show whether or not signal levels comply with the cable system s specifications with their green yellow and red bars 3 1 Main window Below is a capture of a Tilt window with a brief explanation of its features Selected channels A Tilt measurement han in Ens 2 g Ze between the a Bian selected channels e w a
22. of the HUM List of measurements measurement with pass fail indicators Color according to checkmarks 7 2 Setup e Press to change Voltmeter 8 Hum options Volt Hum 10 50PM Setup Tuning Channel k Save datalog Tuning Channel Frequency Save datalog Saves the current scan measurements You can see the datalogs using the remote control application Displays a bar chart representing the equalizer coefficients needed to correct the phase and amplitude distortions in the QAM signal This feature helps identify impedance mis matches echos and micro reflections 8 1 Main window Below is a capture of an Equalizer window with a brief explanation of its features Selected channel List of Change using So et measurements ROA I n na o ze Y with pass fail u indicators TS Equa i zer 64QAM CH 60 786 0000 MHz MER CBER 6 0E 8 Bar graph of the equalizer coefficients Televes 8 2 Setup nu Press sere to change Equalizer options Setup Equalizer Parameters o Channel SAVE Tuning Save datalog Parameters Auto 6 MHz 7MHz 8MHz Bandwidth Auto 6 MHz 7MHz 8MHz Symbol Rate Auto 6111 5156 Other Constellation Auto 4QAM 16QAM 32QAM 64QAM 128QAM 256QAM Standard ITU J 83 A J 83 B J 83 C DFE OFF ON Tuning Channel Frequency Save datalog Saves the current scan measurements You can see the datalogs using the remot
23. r r H30 Learning Plan you 30 Ingress Scan Setup Important You need to have a connection to the internet Configure your network parameters see section 1 Network setup Then select the Network option and then the Setup menu IP selection can be Auto or Manual If you choose Manual you must set the IP address gateway and DNS in the Man items 1 Connect the H30 to the external power supply using the source provided with the meter Connect the H30 to the Internet gt Network 76 55AM 5 Manual Network Info o Man IP 192 168 616 161 Man GW 197 168 016 749 Man UNS 0DE 008 008 O08 2 In the main menu select the fuction Setup If you choose Auto you can see the IP that the Then select Update firmware H30 chose automatically in the Network Info none Settp Gy menu A Quality profile Headend Plan FCC STD Network Time and Date Energy v 3 Press OK and the select On Press OK again to select the On option 4 Turn the meter off by pressing the Device On 3 Remote Control Off button for some seconds Allows remote use of the H30 with your web browser Checking new version 5 The meter will connect to our server download the new firmware and install it in your H30 This process will take around five minutes You need to have a connection to the internet Your web browser must support HTML5 Downlo
24. s Ping meth and serva delay upload speed name IE 12 Service Info Option 593210 The H30 s Service Info feature will tell you what program content is on that QAM channel In addition to the short description of the service you ll get the important parameters including the NIT Network Information Table PAT Program Association Table TSID Transport Stream Id and CBRT Channel Bit Rate for the channel And for each individual service you ll get the SID and the VID Video Id AID Audio Id encode type and bit rate for both the audio and video all of which greatly help when trouble shooting your encoder configuration 12 1 Main window Below is a capture of a Service Info window with a brief explanation of its features MPEG channel info MW 60 786 0000 MHz NIT 0 TELEVES TSID PAT 5 Services CBRT SERVICES TVE HD Pruebas 8 92Mbps TDP 7 49Mbps Radio Clasica HQ 501kbps Radio 3 252kbps Canal Ingenieria 119kbps Y 9c40 33 04Mbps gt gt 2 2 a List of services of the channel with the bit rate of each one and the icon that indicates the type of service go A Select AA a H30 CATV Meter Analyzer Once a service is selected it will be displayed the information for that service SID VIDEO VID Bitrate lt AUDIO 1 1 AID Bitrate Sax Uo HAS 13 Setup Change
25. sruption so having a good reverse path ingress scan tool is a must 10 1 Main window Below is a capture of an Ingress Scan window with a brief explanation of its features Selected frequency Change using Level of the on selected frequency Ingress 24 4250 MHZ Level Wy i KENEN TA i abai 10 53PM Mp 32 2 dBmv Yellow mark Blue graph Red line indicates max hold indicates the selected White graph the current frequency in real time maximun the spectrum green graph level min hold 10 2 Setup ed Press to change Ingress Scan options 5 42 MHz 5 68 MHz 5 85 MHz Ingress frequencies 5 47 MHz 5 68 MHz 5 85 MHz Select the span of the graph re 11 Speed Test Option 593211 Allows you to check your basic network performance parameters so you don t need to get your laptop out This function attempts to connect to the server the server is selected automatically by the H30 by location checks the DHCP protocol and the connection to the Internet If it is all right the H30 makes a ping to the server and shows the delay times Finally the H30 makes a download and upload speed test To start a new test prees OK button 11 1 Main window Below is a capture of a Speed Test window with a brief explanation of its features 513796 337 32 Telefonica de Espana PING TESIT 76 ms Porto Portugal Vodafone PT ST Running 2 1 Mbs Mi Mb
26. tative Person s Name Jos L Fernandez Carnero Signaf Televes televes com

Download Pdf Manuals

image

Related Search

Related Contents

U BBQ User Manual  Murphy MGC 150 User's Manual  Contactar al centro de  1. Institución Escuela Superior de Ciencias Empresariales Inteseg 2  Tipo 252  GESTÃO FINANCEIRA E DE VENDAS  BEDIENUNGSANWEISUNG  Operation and Service Manual for HERMetic UTImeter Rtex  Redes VC70 FT  4. MANEJAR LOS RESULTADOS  

Copyright © All rights reserved.
Failed to retrieve file