1. II Collector Rings a Corrosion and debris on brush holders b Corrosion and deterioration on shaft assembly ll Causes Specific to Valley Branded Pivots a Tower Boxes i The neutral wire that supplies the relay coil circuit chaffs on the sharp edge of the relay back plate Newer tower boxes have a nylon cable strap to prevent chaffing ii Moisture corrosion and debris build up on the terminals of the micro switches mounted to the bottom plate of the tower box b Neutrals although the alarm connects to the neutral wire white of the span cable most of the other conductors in the cable become part of the supervisory circuit i At each intermediate tower box the neutral white is connected to the forward and reverse conductors brown orange through each motor contactor relay coil and micro switch 600 ohms ii The de watering timer at the second to last tower connects the neutral wire white to the safety out yellow red and safety return yellow through the timer clock motor 1200 ohms iii The percent timer purple is connected to the neutral through the relay coil in the end tower 600 ohms iv The end gun circuit pink is connected to the neutral through the solenoid coils c Corner Arms depending on methodology at install time certain Valley branded corner arm pivots may require an isolation relay in the end tower to disconnect the neutral conductor from the corner arm when the pivot is off The relay coil
2. Net Irrigate LLC netirrigate Installation Checking the Pivot If the span cable theft alarm function of the NETB12WR will be utilized it is best to confirm the resistance between the ground and neutral conductors on the pivot Recall that the span cable alarm is activated when the bond between the neutral control circuit conductor and the equipment grounding conductor is broken 1 Locate the control transformer in the pivot control panel Remove the bonding wire green from terminal X2 on the control transformer Re tighten the terminal screw to hold the remaining neutral wires white in place on X2 2 Ifthe pivot is equipped with a modern relay board disconnect the clip to the relay board that contains ground and neutral conductors 3 Using an analog ohmmeter measure the resistance between the bonding wire green and terminal X2 white on the control transformer The measured resistance should be greater than 50k 50 000 ohms If the measured resistance is greater than 50k ohms replace the bonding wire green on terminal X2 of the control transformer and proceed to mounting the NETB12WR on the end tower of the pivot If the measured resistance is less than 50k ohms see Appendix F entitled Common Causes of Low Ground Resistance Mounting and Wiring the NETB12WR Ideally the NETTB11 should be mounted on the end tower of a pivot This provides for greatest accuracy when utilizing GPS services Likewise mounting
3. clothes line on a Lockwood pivot will cause it to stop The NETB12WR will hold the short OPEN while the pivot is running in forward or reverse An incoming remote shutdown command Snare ees will drop out the AC Line on the red wire closing the contact between neutral and the clothes line 6 The blue wire on the NETB12WrR is unused Tape or cap off 7 Connect the green wire on the NETB12WR to GND NETB12WR Connection WHT Cord Orange BLK Netlrrigate Part DIODE FORK Call to Order 1 Black To clothes line safety wire White O zZ Blue O Safety D Resistor a pink y Unused ge Tape Off D yellow To clothes line Safety orange O safety wire Transformer purple brown 1 i white L 2 O NC Control Relay Lockwood End Tower Box 120VAC Coil Oo om Page 18 of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC netirrigate Appendix E Pierce Branded Pivots Wiring Diagram 1 Remove yellow wire from outgoing side of the safety out terminal and connect the black wire on the NETB12WR to the terminal instead 2 Wire nut the removed yellow wire to the red wire on the NETB12WR 7 3 Connect the white wire on the NETB12WR to terminal 7 neutral 4 Connect the green wire on the NEB12WR to GND 5 The blue wire on t
4. netirri PART NETB12WR User Manual and Installation Guide The WireRat Part NETB12WR is designed for the monitoring of electrically driven pivots only For hydraulically driven pivots please refer to the user manual and installation guide for part NETB12TL Copyright 2012 Net Irrigate LLC All rights reserved This publication may not be reproduced in part without prior written consent from Net Irrigate LLC Net Irrigate LLC makes no representations or warranties with respect to the contents hereof and specifically WIRE RAT disclaim any implied warranties or merchantability for any particular purpose Net Irrigate LLC reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation to notify any person or organization of such changes Netlrrigate WireRat and its associated logos are registered trademarks of Net Irrigate LLC Other trademarks trade names and logos published in this manual belong to their respective owners Revision History Description Rev DE a pe a Customer Support Email support netirrigate com Phone 800 961 9549 x2 www netirrigate com November 6th 2012 Initial release of manual December 10 2012 Updated wiring diagrams Business Address Net Irrigate LLC 4201 E 3 ST Bloomington IN 47401 netirrigate STANDARD HARDWARE amp SOFTWARE TERMS AND CONDITIONS 1 Grant of Li
5. can be supplied by safety out yellow red If an isolation relay is not used the span cable to the corner arm will not be protected by the span cable alarm Page 20 of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC netirrigate Appendix G Troubleshooting False Alarms False alarms may be triggered when the circuit resistance between the span cable neutral conductor white and the span cable ground conductor green rapidly increases to more than 50K ohms Large changes in circuit resistance CAN be tolerated without triggering the alarm For example e Abrupt changes in circuit resistance from near 0 ohms to 20K ohms will not trigger the alarm The circuit resistance can repeatedly be changed from 0 ohms to 20K ohms without triggering the alarm e Gradual changes in circuit resistance from near 0 ohms to 50K ohms will not trigger the alarm Symptom Probable Cause and Remedy False alarms repeatedly are AC Line is not connected to the black conductor on the generated while the pivot is NETB12WR connection cord The AC Line can usually be running in either direction tapped off the pivot s 120VAC safety circuit See appropriate wiring diagram False alarms occur repeatedly Diode fork faulty or improperly installed only when pivot is running in one direction Blue wire on NETB12WR not connected to REV Black wire on NETB12WR not connected to FWD False alarms randomly occur Dirty collector r
6. may contact customer support at 800 961 9549 and an agent will attempt to locate the pad of the pivot using Google Earth Virtual Stop In Slots Because the Netlrrigate servers are monitoring the heading of the pivot notifications can be configured when the pivot reaches a desired a heading Likewise the pivot can be configured to automatically shut down when a desired heading is met Up to 16 different virtual stop in slot points can be configured Virtual stop in slot points can be configured via the Netlrrigate web portal or by calling customer support at 800 961 9549 Sample Virtual Stop In Slot Configuration Screen on netirrigate com Ce 5 www netirrigate net IrrigationSites VirtualSIS 888233 siteld 555072 netirrigate Customers Irrigation Sites Notifications Reports Telemetry Boxes Administration Log Off Password A Customer DeSalle Edward Net Irrigate LLC v Site Scott Demo 102102 v Site List Details Linked Telemetry Boxes Associated Rate Plans Virtual SIS Partial Circles Heading Stop Pivot at Heading 90 00 False Delete 220 00 True Delete 355 00 False Delete lf you ve selected to automatically stop your pivot at the stop in slot heading the auto stop attribute will automatically become unchecked once your pivot reached the desired heading This is SO you can successfully restart your pivot Add New Virtual Stop in Slot Page 8 of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012
7. on the end tower provides for maximum protection against span cable theft 1 Ensure power to the pivot is completely off and the control panel is locked 2 Climb the tower of the pivot and allow the powerful magnets on the back ot the NETB12WR to adhere to the angle iron of the pivot The NETB12WR should be positioned vertically 3 Remove the cover from the tower electrical box 4 Ifthe bottom of the tower box is not equipped with a standard NPT knock out drill an appropriate hole to fit the black NPT cord grip which is included in the NETB12WR packaging 5 Install the supplied cord grip and lock nut 6 Run the tray cable from the NETB12WR through the cord grip and into the tower box Page 9of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC netirrigate 7 Follow the appropriate wiring diagram depending on the brand of pivot Refer to the tables below If installing on a pivot brand not listed please contact customer support at 800 961 9549 For setups WITHOUT implementation of remote shutdown functionality NETB12WR Wire Color Black Blue Red NC Relay White Neutral 120VAC In 120VAC In Out 120VAC Valley Yellow Red Unused Unused White Grounding Bar Tape Off Tape Off Brown Unused Unused White Grounding Bar Tape Off Tape Off Purple Pink Unused White Grounding Bar Tape Off Lockwood Yellow Orange Unused White Grounding Bar Tape Off Yell
8. please review the document entitled WireRat iPhone App User Guide 3 If you do not have access to a computer or the WireRat iPhone App just contact customer support at 800 961 9549 and an agent will setup the customer site and notification recipients for you Notification recipients are the people who are contacted either via voice call text message or email when cable cut safety stop or virtual stop in slot events occur at the pivot Up to ten notification recipients can be configured per pivot Notification recipients can be easily enabled or disabled by using the web portal iPhone app or simply by calling customer support at 800 961 9549 Page 6of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC netirrigate Functional Principles Battery Backup The NETB12WR utilizes a custom designed lithium battery pack which is designed to operate the interval cellular radio modem for at least three years Expected battery life could be as long as five years depending on environmental conditions and frequency of pivot operation A working battery is imperative for proper functionality The battery can be tested by following the bench testing procedures of the previous page Span Cable Theft Detection The NETB12WR checks for cut wire by sending a small supervisory current through the neutral and ground conductors of the pivot s span cable When this supervisory current is inter
9. rights duties or obligations hereunder in whole or in part without the prior written consent of Net Irrigate Customer shall not disclose the terms and conditions of this Agreement except as may be required to implement and enforce the terms of this Agreement or as may be required by legal procedures or by law In all matters relating to this Agreement Customer and Net Irrigate shall act as independent contractors This Agreement shall be governed construed and interpreted under the laws of the State of Indiana to the exclusion of any conflict of law or choice of law rule or principle that might refer construction or interpretation of this Agreement to the substantive law of another jurisdiction Any action to enforce this Agreement or for breach of this Agreement shall be brought in a state or federal court situated in Marion County Indiana and each of the parties hereby consents to personal jurisdiction of and venue in such courts and waives any future right to object to this designation of jurisdiction and venue The waiver or failure of any party to exercise in any respect any right provided for under this Agreement shall not be deemed a waiver of any future right hereunder This Agreement shall bind the parties their permitted successors heirs and assigns No provision of this Agreement which may be found to be unenforceable shall in any way invalidate any other provision or provisions of this Agreement all of which shall remain in full force
10. together and then breaking the circuit This action will initiate a diagnostic test on the unit and will text you when complete The entire test should take about 3 minutes 5 Within 3 minutes you should receive the text message Bench test successful Device 333001 is functioning properly and registered on the Netirrigate network 6 If you receive an error message from our server or do not receive a text message indicating success within 3 minutes please contact customer support at 800 961 9549 x2 Customer Site and Notification Recipient Setup Before mounting the NETB12WR on an actual pivot it is best to setup the customer information the irrigation site details and the intended notification recipients in the Netlrrigate system Additionally you will need to link this information to the Device Id you intent to mount Setup is fast and easy and can be accomplished through one of three possible ways 1 Login to www netirrigate com If you do not yet have a username and password for your dealership please contact customer support at 800 961 9549 or email support netirrigate com For details on how to utilize the dealer portal on www netirrigate com please review the document entitled Web Portal User Guide 2 Login to the WireRat iPhone App WireRat is available in the App Store You may use the same login information as you would use to login to www netirrigate com For information on how to use the iPhone app
11. T CONSEQUENTIAL EXEMPLARY PUNITIVE OR INCIDENTAL DAMAGES INCLUDING LOSS OF DATA REVENUE PROFITS CROPS OR OTHER ECONOMIC ADVANTAGE EVEN IF IT HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AND EVEN IF SUCH DAMAGES ARE DIRECTLY OR INDIRECTLY CAUSED BY NEGLIGENCE OR A TORT COMMITTED BY NET IRRIGATE ITS AGENTS OR ITS ASSIGNS THE MAXIMUM LIABILITY OF NET IRRIGATE TO ANY PERSON FIRM OR CORPORATION WHATSOEVER ARISING OUT OF OR IN THE CONNECTION WITH ANY LICENSE USE OR OTHER EMPLOYMENT OF THE NETB12S WHETHER SUCH LIABILITY ARISES FROM ANY CLAIM BASED ON BREACH OR REPUDIATION OF CONTRACT BREACH OF WARRANTY TORT OR OTHERWISE SHALL IN NO CASE EXCEED THE EQUIVALENT OF THE PRICE PAID BY THE CUSTOMER FOR THE NETB12S THE ESSENTIAL PURPOSE OF THIS PROVISION IS TO LIMIT THE POTENTIAL LIABILITY OF THE PARTIES ARISING FROM THIS AGREEMENT THE PARTIES ACKNOWLEDGE THAT THE LIMITATIONS SET FORTH IN THIS SECTION 4 ARE INTEGRAL TO THE AMOUNT OF CONSIDERATION LEVIED IN CONNECTION WITH THE LICENSE OF THE SERVICE AND THAT WERE NET IRRIGATE TO ASSUME ANY FURTHER LIABILITY OTHER THAN AS SET FORTH HEREIN SUCH CONSIDERATION WOULD OF NECESSITY BE SET SUBSTANTIALLY HIGHER CERTAIN STATES AND OR JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR LIMITATIONS OF LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE EXCLUSIONS SET FORTH ABOVE MAY NOT APPLY TO YOU 5 Government Rights The Licensed Software is Commercial Computer Software under Feder
12. WR can send text voice Notifications or email notifications that the pivot s safety circuit has opened Remote Shutdown The NETB12WR contains a normally closed relay which can be wired in series with the pivot s safety circuit Once configured the normally closed relay can be actuated via a phone call to our interactive voice response system by calling 800 961 9549x7 GPS Monitoring and The NETB12WR facilitates graphically monitoring the heading of a center pivot via a Virtual Stop In Slot website In addition the NETB12WR can be used to provide virtual stop in slot alerts Notifications such that text voice email notifications or remote shutdown commands are sent when a pivot reaches desired field headings Section North East Eo Rd40 oo Rd 0 n o Rd m e Red 40 Co Rd 40 Example The NETB12WR can send notifications or stop the pivot when the heading is at 270 degrees a Lei H ah kj o D a a D a 4 Google oc IONE r E202 DigtalGlobe GeoEye Texas Orthoimagery Program USDA Fann Service Agenc S Page 4 of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC netirrigate Getting Started Identifying the Device Id All NETB12 products are uniquely identified by a 6 digit serial number which is barcoded on both the packaging carton and the physical unit Net Irrigate refers to this number as the Device Id Package Contents All NETB12WR units ship wi
13. al Government Acquisition Regulations and agency supplements to them If the Licensed Software is provided to the Federal Government and or its agencies it is provided only under the Restricted Rights Provision of the Federal Acquisition Regulations applicable to Commercial Computer Software developed at private expense and not in the public domain The use duplication or disclosure by the Federal Government and or its agencies is subject to restrictions as set forth in subdivision c ii of the Rights and Technical Data and Computer Software clause at DFARS 252 227 7013 and FAR 52 227 19 c 6 Export Controls Customer acknowledges that the licensing and distribution of the Licensed Software is subject to the export control laws and regulations of the United States of America and any amendments thereof which restrict exports and re exports of software technical data and direct products of technical data Customer agrees that it will not export or re export any Licensed Software or any information or documentation related thereto directly or indirectly without first obtaining permission to do so as required from the United States of America Department of Commerce s Bureau of Export Administration or other appropriate governmental agencies to any countries end users or for any end uses that are restricted by U S export laws and regulations and any amendments thereof 7 Miscellaneous Customer may not assign transfer or delegate any of its
14. ally reports latitude and longitude which results in the heading of the pivot to be between 87 and 93 The tolerance window is designed to compensate for the wide variance in pivot speeds and percent timer settings Site Status Site History Water Usage Rainfall Net Irrigation Site Status Auto Reload in 38 seconds Site Name Site Type State Flow Rate Heading Zone Last Updated Boxes Air 05 Center Pivot L Stopped No Meter 351 9 3 2012 6 00 PM 102090 Edit Alls 01 Center Pivot L Stopped No Meter 10 11 2012 9 10 AM 101280 Edit Alls 02 Center Pivot ee Moving No Meter 303 10 22 2012 5 26 PM 102150 Edit Alls 03 Center Pivot L Stopped No Meter 281 10 22 2012 5 30 PM 102030 Edit Page 14 of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC netirrigate Appendix A Valley Branded Pivots Wiring Diagram f rmsnnsnnnnnnnnnnnnnnnnnnnnnnnnNNNNNNNANNNNNNNNNNNANNNNNANNENNANNNNNANNNNNANNNNNANNENNANNNNNANNNNNANENNNANNSNANANENNNANNENNANNNNNANNSNENANENNNANNNNNANNNNNANNNNNANNNNNENNENNANNNNNENNENNAANNNNEANSNNANNNNENEANENNAANNNNAANNNNANNNNENEANENNAANNNNEANNNNEANNNNEANENNEANNNNEANENNEANNNNEANENNEANNNNEANENNEENNNNEANENNEENNENEENENE 1 Remove the yellow red wire from the load side of the terminal strip 2 Connect the red wire from the NETB12WR to terminal 9 where the yellow red wire was 3 Wire nut the removed yellow red wire to the black wire on the NETB12WR 4 Connect the white wire on the NETB12WR to
15. and effect Any ambiguities in this Agreement shall not be strictly construed against the drafter of the language concerned but shall be resolved by applying the most reasonable interpretation under the circumstances giving full consideration to the intentions of the parties at the time of contracting There are no representations promises warranties or understandings relied upon by Customer which are not contained herein Customer shall be responsible for any and all taxes applicable to this Agreement excluding taxes on the income of Net Irrigate In any collection action or litigation relating to this Agreement Net Irrigate shall be entitled to recover its costs of collection or litigation including reasonable attorney s fees This Agreement and the Net Irrigate User Agreement constitute the entire understanding between the parties with respect to the subject matter hereof and cancels terminates and supersedes any prior agreement or understanding relating to the subject matter hereof between Net Irrigate and Customer Any modifications to this Agreement must be in writing and signed by both parties Page 2 of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC Contents ADICIONE Omer er ene ene ee E EO ee Pr A eee ene eer eee eee 4 COTES starne ccs Sts sees aE 5 ECE VS te Device Iiis se soairecusenass sissies nat oadia genes E cess 5 Pacae Oe g 91 ao ee en a ec Ce nee en eS ee enon ore 5 Benon Te NE
16. anel at the pad and ensure the power to the panel is completely off 2 Open both panel doors such that the control transformer within the pivot panel can be accessed 3 Ifthe pivot panel is equipped with a relay board disconnect the clip to the relay board which may contain a neutral and ground conductor 4 Locate X 2 on the control transformer This is where the white and green wires are bonded 5 Remove the terminal screw and separate the white wire and the ground wire for at least 5 seconds 6 Replace the wires and be sure to re tighten the terminal screw 7 Wait at least 3 minutes for a text voice or email alert which indicates a possible theft is occurring If an alert is not received try testing with the alternative method on the following page ZH OS 0G ala ZH OS 0S St9 Nal YS e3 E sic a gt 41 gt s f I F ifs 4 f E ni Page 11 of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC netirrigate Alternative Method 1 Ensure power to the pivot is off and the control panel is locked 2 Walk to the first drive tower climb it and remove the tower box cover 3 Note the terminal numbers of where each wire is connected There are two gauges of wire in the tower box The smaller wire is what you will be working with The span cable heading out toward the end tower is what will need to be disconnected sequentially 4 Remove each 120VAC control c
17. cense Subject to Customer paying all amounts payable hereunder Net Irrigate LLC Net Irrigate grants to Customer a non exclusive nontransferable license during the term hereof to use the software embedded in Netlrrigate branded products the NETB12s for irrigation systems owned by Customer the Licensed Software for Customer s internal monitoring and data processing needs 2 Ownership of the Licensed Software Net Irrigate shall retain title to and ownership of the Licensed Software Net Irrigate reserves all rights not expressly granted herein The Licensed Software may not be used beyond the scope of the license expressly granted herein Customer shall keep the Licensed Software confidential Customer may not alter modify or adapt the Licensed Software or documentation including but not limited to translating reverse engineering decompiling disassembling or creating derivative works Customer shall promptly report any infringement of the Licensed Software of which it becomes aware and shall cooperate with Net Irrigate in protecting Net Irrigate s proprietary rights in the Licensed Software 3 Term and Termination This Agreement shall take effect upon the delivery of the NETB12s to the Customer and shall terminate 99 ninety nine years from therefrom 4 Warranties and Liability CUSTOMER ACKNOWLEDGES AND AGREES THAT NET IRRIGATE SHALL HAVE NO LIABILITY ARISING FROM THE OPERATION OR USE OF THE NETB12s FOR SPECIAL INDIREC
18. e has stopped walking 5 Repeat the process by walking the pivot in the opposite direction To ensure proper functionality it is important to walk the pivot in BOTH directions 6 If any of the notifications fail please contact customer support at 800 961 9549 Testing Remote Shutdown Remotely shutting down the pivot is accomplished through the Netlrrigate Remote Shutdown Line The Netlrrigate Remote Shutdown Line uses caller id security to identify your list of pivots available for remote shutdown To enable your phone to initiate remote shutdown calls make sure your phone number exists and is enabled within the Remote Access tab within the Netlrrigate Web Portal e CL www netirrigate net Customers RemoteAccess 888233 netirrigate Customers Irrigation Sites Notifications Reports Telemetry Boxes Administration Log Off Password a Customer DeSalle Edward Net irrigate LLC v Create New Customer Customer List Customer Details Associated Logins Address Book Remote Access Create New Remote Access Number Phone Number Description Phone Number Enabled Last Changed Bugs Bunny 555 212 8989 10 22 2012 3 57 37 PM by edesalle Edit Delete To initiate a remote shutdown call simply dial 800 961 9549 x7 The automated system will read off a list of your pivots available for remote shutdown Follow the voice prompts and your pivot should shut down within two minutes You will receive a safety stop notification
19. e ene en eee eS er ee ee ee 6 Customer Site and Notification Recipient Setup ccccceseccccesseccceesececeeeececeeescceseeseceseunecesseneceeteneeeetas 6 PUCCIO Gal FING WIGS soc epacs ousted ciace nn ssesncateasnncesssenccavestaceantienec T emis tecensno enaauecederece 7 Baen BACK a sadurteiuedhonsddtsaet E 7 Span Cable TRER Detect ensnare T N 7 AE OP AO a E E N 7 REME SIO GONT o A E TE 7 PMO ORNE ea E E E E E E E E E 8 PPV OC Se OVENS sereis naine EE 8 WAN SU OTN SOS cesarean aseneroecenaniceaetacoedoinessuannacdeaeuapacatiabosatecnasnanseoeademene E 8 PT SUS ACUI EAE EEE E EEE E EEEE A E E EA vec A E IEP OE E E 9 FS SIU Est og norvasc E E E E E EA 9 Mounting and Wiring the NETBL2WR sssessesesssnssseesesrerssrrereserrsssrereserrsssreresererssreresererssreresererssrereseereseeees 9 TESE FOC UNS aar E EE T T 11 Smutne Span CIDEC UTS cerren EE E E EA ERAN 11 Pra MEO eE EA ee ee 11 Area VE MEO en E E oh stained E E E S 12 Testine Safety Stop NOtINCALIONS accossesesecsesesscccanscecevertosedvanaeaasuconsssouttaenteudsaauebsenioataeeanacsocdsasntnediaeeceseatsees 13 TENE RMO M OW a ict seers ncle doa tese amc sae eats bates Satin eee ame eco 13 Testne GP aceron E E EE E E 14 Appendix A Valley Branded Pivots Wiring Diagram essessesssseeseserrssrrrssrrrssrreresrressseereserereseereserereseerese 15 Appendix B Zimmatic Branded Pivots Wiring Diagram ccccscccssscccsececssececenecceeneceeeeceseeecessuecenseeeeees 16 A
20. he NETB12WR is unused black blue red brown orange white yellow purple pink Yellow red NET12WR User Manual and Installation Guide Rev B Pierce End Tower Junction Box TIMER END GUN AUTO REV Grounding Bar CF ee O L n NETB12WR S146 BY 2WR Mounting Side View My Mout Mag L w Cord Grip Neutral WHT BLUE Unused Tape Off AC Line IN BLK NC AC Line Out RED Wire nut to YELLOW safety out GND Wire GRN Page 19 of 21 Copyright 2012 Net Irrigate LLC netirrigate Appendix F Common Causes of Low Ground Resistance Three different types of digital multi meters were field tested for measuring span cable resistance All three digital meters gave erroneous readings We assume that the capacitance between the span cable shield and the span cable conductors produce unreliable digital meter readings The WireRat span cable alarm will function if the open circuit resistance is 50 000 ohms or higher If the open circuit resistance is lower than 50K ohms locating the source of the grounds can be both difficult and time consuming Some of the most likely causes of low ground resistance measurements are as follows I Running Lights a Flexible cords to the running lights are cracked and water logged b Running light lamp sockets are deteriorated and leak to ground
21. if remote shutdown is successful Page 13 of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC netirrigate Testing GPS Successful GPS monitoring begins by ensuring the latitude and longitude of the pivot pad have been entered into the Netlrrigate servers The latitude and longitude of the pad may either be entered via the WireRat iPhone app or via the site details tab in the NetlIrrigate web portal Site List Details Linked Telemetry Boxes Associated Rate Plans Virtual SIS Partial Circles Owned By Site Location DeSalle Edward Net Irrigate LLC 7 Nick Name Site Id Julie Demo A 555368 Time Zone Latitude Longitude Eastern UTC 5 41 218583 87 163136 Site Type Brant Length Center Pivot Select Brand Notes mal MOOR Pi vie 56 X gle i e GeoBye IndianaMap Framework Data USDA Farm Sefvice A Save Irrigation Site To acquire an initial pivot heading run the pivot for at least 15 minutes Once a GPS fix is established the pivot heading should update on the Site Status report within the Netlrrigate web portal If a virtual stop in slot alert is configured the notification will trigger when the pivot is within 3 degrees of either side of the configured heading For example if a virtual stop in slot notification is configured at 90 the stop in slot notification will occur when the NETB12WR periodic
22. ing most common on Zimmatic pivots when pivot is sitting idle Clean collector ring with emery cloth Corroded rotary brush assembly at collector ring Install a 2000 ohm 5 watt resistor between the neutral conductor and ground conductor across the outbound span cables at the collector ring Loose connection on ground or neutral terminals in tower boxes This may occur due to deteriorating span cable cord grips on tower boxes False alarms occur on pivot start Barricade stop is holding safety circuit open longer than up only expected thus NETB12WR cannot see AC Line signal until pivot moves completely off the barricade Rewire to junction box before barricade stop switch Barricade stop switch is opening neutral conductor Transient voltage spikes from generator Leave pivot panel in the OFF position while starting up generator False alarms when pivot stops Loose neutral or ground on pivot NETB12WR box not securely mounted and rattling Page 21 of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC
23. ircuit wire This includes safety forward reverse percent timer and end gun REMOVE THE WHITE NEUTRAL CONDUCTOR LAST 5 Wait at least 30 seconds and replace the wires to their respective terminals 6 Replace the tower box cover 7 Wait at least 3 minutes for a text voice or email alert which indicates a possible theft is occurring If an alert is not received please contact customer support at 800 961 9549 Page 12 of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC netirrigate Testing Safety Stop Notifications Before testing for safety stop notifications at least one notification recipient should be configured for the site in question If this has not been done please see previous section Customer Site and Notification Recipient Setup If desired safety stop notifications can be configured for when the pivot both starts up and stops walking Once it is determined that notification recipients have been configured for each respective alert follow the procedure below 1 Start the pivot walking in either forward or reverse In about three minutes you should receive a message that says Netirrigate Site Name is now running Where NetIrrigate Site Name is the alias you ve given to the irrigation site 3 Once you receive the notification that the system is running stop the pivot Within three minutes you should receive a message that says Net rrigate Site Nam
24. ow Unused Unused White Grounding Bar Tape Off For setups in which remote shutdown functionality WILL be implemented see wiring diagram in the respective Appendix listed below O ss c O 6 oO O ca gt s Pivot Brand Additional Relays Needed Appendix Page Valley No A 15 Zimmatic No B 16 Reinke Yes only required for remote shutdown C 17 Lockwood Yes only required for remote shutdown D 18 Pierce No E 19 8 Once the NETB12WR wires are connected to the appropriate terminals replace the cover on the tower box 9 If necessary zip tie the NETB12WR tray cable away from the mechanical levels beneath the tower electrical box to avoid kinks or obstructions 10 Wrap the included 24 heavy duty UV resistant nylon cable tie around the NETB12WR unit for added security While the mounting magnets are extremely strong the cable tie is designed to protect against extremely severe weather Page 10 of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC irrigate Testing Procedures Simulating Span Cable Cuts Before testing the cut wire alarm at least one notification recipient should be configured for the site in question If this has not been done please see previous section Customer Site and Notification Recipient Setup Once it is determined that a notification has been configured for a span cable cut event follow the procedure below Primary Method 1 Goto the main p
25. ox black red blue brown Safety return to tower light panel yellow pink orange purple white green Page 16 of 21 Copyright 2012 Net Irrigate LLC netirrigate Appendix C Reinke Branded Pivots Wiring Diagram 1 Install relay with 120VAC coil and NC NO contacts as shown below The common on the relay should connect to the blue wire on the NETB12WR 2 Remove the Reinke brown wire from terminal 5 and wire nut to red wire on the NETB12WR METELAU 3 Connect the black wire on the NETB12WR to terminal 5 Connection Heuer 4 4 Connect the white wire on the NETB12WR to terminal 1 neutral Cor 5 Connect the green wire on the NETB12WR to Ground BLK amp YI GDIO OlSG OO SI OIS 12 3 4 5 6 7 8 9 10 amp DIQ E lC Span Cable from Pad Spon Bar Reinke C BOX End Tower Terminal Strip Page 17 of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC netirrigate Appendix D Lockwood Pivots Wiring Diagram 1 Install the Netirrigate DIODE FORK on the forward and reverse control circuit terminals The orange wires on the DIODE FORK should be attached to these terminals Connect the Blue wire on the DIODE FORK to the Black wire on the NETB12WR Connect the White wire on the DIODE FORK to any neutral terminal Install a control relay with NC contacts and a 120VAC coil as shown below Note that shorting neutral to the
26. ppendix C Reinke Branded Pivots Wiring Diagram ccccsssssssccccecsceeesseecccceeesaeesseeececeessuaeseeeeeeeeesaaas 17 Appendix D Lockwood Pivots Wiring Diagram cccccccsseccccessececeeseceecenscceeeuseceseuneceeeeueceessusecessenecessenes 18 Appendix E Pierce Branded Pivots Wiring Diagram ccccscccsssecccsseecenececenececeneceeeneeeeencesaunceseuecesseeeeees 19 Appendix F Common Causes of Low Ground ResistanCe esssssssssessreresrrrsrreresrrerssreresereresrereserersseerese 20 Appendix G Troubleshooting False Alarms cccccssseccccsssccccessececeesececceecceeeusecessuneceseuneceeseusecessenecesseees 21 netirrigate Applications Part NETB12WR branded the WireRat is specifically designed to be mounted on the end tower of any brand of electrically driven center pivot Once installed and properly configured the NETB12WR provides the following remote monitoring functions Span Cable Theft The NETB12WR is the only copper theft alarm product that works seamlessly with all Notifications brands of pivots and requires no external power The NETB12WR utilizes a patent pending supervisory circuit that works strictly on lithium battery power for 3 to 5 years When a pivot s span cable is cut or tampered with the NETB12WR sends instant text voice or email notifications that a possible theft is occurring Pivot Safety Stop When a pivot transitions from walking to stopped the NETB12
27. rupted an alarm code is triggered The supervisory current is generated by the internal NETB12WR batteries and works seamlessly with normal pivot operation For the span cable alarm to properly arm itself at least 50 000 ohms of resistance must exist between the ground and neutral conductors when separated at the control transformer or outgoing side of the collector ring Safety Stop Alerts The NETB12WR transmits safety stop notifications when it detects a closed to open transition in a pivot s 120VAC safety circuit The NETB12WR must see the circuit open for at least 40 seconds before transmitting a wireless notification that the circuit transitioned from closed to open The time delay is to prevent false alarms due to loose wires pivot jogging and auto reverse functionality On non standard pivots paralleling off of any 120VAC control circuit that is hot when the pivot is running in both forward and reverse will suffice in monitoring for safety stops Remote Shutdown If the NETB12WR is wired correctly it may be used to remotely stop a center pivot Each NETB12WR is equipped with a normally closed control relay When a remote shutdown call is initiated the coil on this control relay is wirelessly picked up thereby interrupting the normally closed safety circuit When the NETB12WR senses the 120VAC supplied by the pivot panel has dropped out the coil of the relay de energizes and the contact closes again thereby allowing the pivot to res
28. tart For remote shutdown functionality to properly work the NETB12WR must remain ON until the pivot completely drops out The NETB12WR must still receive 120VAC from the main pivot panel until the delay timer in the pivot drops out The remote shutdown functionality utilizes the red wire in the NETB12WR connection cord If wiring for remote shutdown is not desired tape off the red wire and do not put the safety circuit in series with the NETB12WR Instead just parallel the black wire in the NETB12WR connection cord to the appropriate 120VAC safety circuit OR connect the black and blue wires to the respective forward and reverse terminals of the pivot To avoid shorts be sure to properly tape or cap off the red wire on the NETB12WR if the unit is not being wired for remote shutdown purposes Page 7 of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC netirrigate GPS Monitoring Pivot Heading The NETB12WR sends longitude and latitude coordinates to the Netlrrigate servers every 15 minutes If the longitude and latitude coordinates of the pivot pad are properly entered as part of the site details the software on the server will use basic trigonometry to determine the angle or heading of the pivot Determining the longitude and latitude coordinates of the pivot pad can be accomplishes with several smart phone apps most consumer GPS devices or even the WireRat iPhone app Alternatively you
29. terminal 7 neutral 5 Connect the green wire on the NEB12WR to Ground 6 The blue wire on the NETB12WR is unused and should be taped off NETB12WR Connection Cord Valley Center Pivot Terminal Strip End Tower Box black S blue A red S yellow brown D orange S WHITE white S Manual Yellow Red from ae S P ower Inner Tower BLK RED Yel Red S O Disconnect 0 gt purple D Unused BLUE ink cap off Pe S GREEN Oe Grounding Bar Page 15 of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC netirrigate Appendix B Zimmatic Branded Pivots Wiring Diagram nunnnnnnnnnNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNANANNNNNNNANMNNNNNNNNNNNNNNNNNANNNNNNNENANNNNENNENMNNNNNNNNNE 1 Remove the brown wire that is heading in the direction of the pivot pad from terminal 4 2 Connect the black wire from the NETB12WR to terminal 4 where the brown wire was 3 Wire nut the removed brown wire to the red wire on the NETB12WR 7 4 Connect the white wire on the NETB12WR to terminal 10 neutral 5 6 Connect the green wire on the NETB12WR to Ground The blue wire on the NETB12WR is unused NETB12WR Connection Cord Unused BLUE Tape Off Safety RED BLK return to panel Wire Nut to Zimmatic Brown wire WHITE GREEN NET12WR User Manual and Installation Guide Rev B Zimmatic Pivot Terminal Strip End Tower B
30. th A NPT Cord Grip to be used with the knock out on the pivot s end tower box Magnetic mounts which come pre installed on the enclosure A 24 heavy duty UV resistant nylon cable tie for safety securing the unit A wire nut which may need to be used if wiring the NETB12WR up for remote shutdown purposes An extra Device Id bar code sticker which can be placed on the panel of the center pivot so the associated Device Id can be identified at the pivot pad ae TT Wat Page 5 of 21 NET12WR User Manual and Installation Guide Rev B Copyright 2012 Net Irrigate LLC netirrigate Bench Testing The NETB12WR should be bench tested before being installed on an actual pivot A simple bench testing procedure ensures a properly functioning unit and adequate wireless coverage Bench testing involves the following procedure 1 Identify the Device Id of the NETB12WR Recall that the serial number is barcoded on the bottom of the unit to the right of the cord grip 2 Use your cell phone to text the phrase TEST XXXXXX to 317 602 1732 Where XXXXXxX is the serial number of the unit Example TEST 333001 3 You should receive a text message back from our server within 60 seconds that says 333001 is ready for bench testing Hold White and GND wire together and then break bond You will be notified in three minutes when test completes 4 Follow the instructions texted to you by holding the White and GND green wires