HWAS-290G / 290GN User Manual

image

Contents

1. Alarm LED 1 ow voltage LED Door sensor main part Magnet bar v door sensor pir sensor with the auto shut off valve Working voltage 12V DC Static current 0 1 uA Working current lt 20mA Frequency 315 433MHz Transmitting distance gt 200m in the open air Detection gap 20mm Indoor use only Do not fall Indoors only do not fall The main part is installed on the door frame and the magnet part is installed on the door Installation height 1 8 2 5m Detecting range 7 13m Operating Voltage 9V Static current 0 Transmit Frequency 433 315 MHz Installation angle 1 5 against the wall Transmit Distance 100m in the open air Do not face the sunshine directly Do not face cold or heat directly Do not face the strong airflow Do not face the fluttering curtain directly Other commonly used sensors Wired Wireless Smoke detector optional The Smoke detector is used to detect potentially dangerous smoke emissions at home Once the detector detects the presence of smoke as a danger and possible fire risk it will transmit an alarm signal to the control panel and also activate its own integral local siren 2 Wired Wireless Combustible Gas detector optional The combustible gas detector will detect potentially dangerous gas emissions within its location It should be fitted in any area where there is a possibility orrisk of gas leaks or emissions Once the combustible gas de
2. control it Call the panel the panel would pick up the phone and says please input the password User enters the password default is 123456 and then he could remote control the panel Press 1 to listen in press 2 to speak press 4 to turn off the listen in and speak press 3 to sound the siren press 6 to turn off the siren press 7 to arm press 8 to disarm press 9 to hear the alarm recording again 0 Press 5 to hang up or user could hang it up directly Installation and usage notice Indoor use and not waterproof please do not install it outdoors Do not put it near metal case TV set PC or other objects with strong electromagnet interference Turn off the panel before you insert or take off the simcard Make sure the power supply is well fitted and cooled Keep a regular check of the sim card make sure it has enough balance P Se N Keep a regular test of the panel performance 12
3. in following steps Enter alarm_system menu choose wired wireless setting choose enable wired zone press y it shows wired port 0 to 15 choose the port which you have connected wired sensor press choose enable At last choose the zone you plan to allocate the sensor to Bind relay to specific zones The panel has 14 relay outputs The relays could be controlled by a text command and they also could be bound to specific zones If one relay is bound to a zone that means once the sensor in this zone is alarming the relay would be driven When the alarm is disarmed the relay would go back to its original state How to bind enter alarm system choose wired wireless setting choose output binding to zones press key choose the zone No press key One relay could be bound to multiple zones and one zonecould bind multiple relays too 11 How to trigger different wireless sensors Door sensor Put the main part and magnet together and then separate them the red led flashes and that means it is triggered Pir sensor Turn on the sensor switch or you simply move in front of the sensor its red led flashes and that means it is triggered Smoke sensor Press the key on the sensor the led flashes and the sensorsounds beep that means it is triggered Gas sensor Press the test key on the sensor its led flashes and that means it is triggered Water leakage sen
4. HWAS 290G 290GN User Manual i ont 3l EER O gt lt 6 English security Wired wireless device Register wireless device FEY SMS plas security A
5. User could disarm the panel within the 15s sensors would not alarm if being triggered in stay arm state e g if we put the living room pir into stay arm zone put the pir in the yard to normal zone When you are at home you could stay arm the system sowhen you walk around and trigger the living room pir it would not alarm Only when stranger trigger the pir in the Stay zone yard and then it would trigger the alarm Away arm send text lt password gt arm e g send lt 123456 gt arm Disarm send text lt password gt disarm e g send lt 123456 gt disarm Check the state send text lt password gt check e g send lt 123456 gt check Reset the default password send text recovery password forced Control the relay output send text lt password gt relay lt num gt lt state gt a lt 123456 gt relay lt 0 gt lt 0 gt the first 0 means the relay NO the second 0 means open 1 means closed b lt 123456 gt relay lt 1 gt lt 1 gt the first 1 means the relay NO the second 1 means closed 0 means open lt password gt is the panel password lt num gt is the relay No 0 or 1 lt state gt is the relay state 10 Recording and recording binding Recording Planning a The panel could have a max 180 seconds recording You could record them in several segments The recording would auto play when the panelalarms so that user could know the alarm pl
6. ace and which zone triggering the alarm b The recording played after alarm could be divided into 2 parts one is the main message the other is the zone message c The main message could be an address like room No Building NO alarm or computer room NO area alarming so that user could know where the alarm is when he has installed more than one panel Zone message would suggest which zone alarm like zone 2 fire alarms zone 3 gas leakage alarms etc User could make records make difference in the recording file names and then bind them to different zones according to his needs Operation Steps a Recording Enter the menu alarm system choose setting press key go to the recording interface Press press to start recording alarm setting choose alarm voice choose the new recording b Bind the recording to zones Enter the menu alarm system choose alarm setting choose alarm voice setting pres key go to therecording interface Press choose list choose the voice file you just recorded press choose use it shows the main message or zone numbers press the up down key to choose at last press key to save it Wired zone enabling and binding with zones The panel could connect 16pcs wired sensors After connecting the wired sensors user has to enable it on the panel and then binding it to zones
7. e How to choose the installation place A On the NO 4 wall not shown in the pic 1 Walk directly facing the pir lens the sensitivity is facing the door B On the no 3 wall facing the door 2 Install it at the aisle entrance and indoors 6 low walk perpendicular to the pir lens the sensitivity is high Alarm system menu and function introduction Alarm System 0 119 0 199 991 Bu yos 1919 14 60 JUBA Alarm number setting 6 group alarm numbers are programmable Alarm mode call text or both Zone text setting user could set the text content for each zone Alarm voice setting 180 seconds voice each zone could have a different recording Sounder silent alarm user could turn on off the inside siren Group message the alarm and command texts could be sent together or in one way Enable the wired zone choose to enable or neglect the wired zone Register wireless device program wireless remote and various sensor to the panel Delete wireless device Delete the wrong or lost remote sensors Delete all the wireless devices clear all the wireless devices in the panel Output binding to zones the wired relay output could bind with a specific zone The number of BUS node setting Set BUS node numbers from 1 to 64 for model B only BUS zone setting set the node on off for model B only BUS node relay control set the node relay no 0 7 on off for mode
8. er Delete wireless device Choose the sensor you plan to delete press lt key Delete all the wireless devices clear all the wireless devices Output binding to zone once a zone is triggered the relay would be driven accordingly E g if you want zone 2 alarm and then relays closed You could set it as follows output bind to zone zone 2 relay 0 closed relay 1 closed at last press backspace key to save it Relay load 7A125V AC 5A 2560 AC 20 14 DC Sensor test It is to test whether the sensor is registered The panel would display the sensor number if the sensor was registered Parameter setting Password setting set the password of the panel default 123456 Delay setting arm alarm delay timer 0 120s the delay timer is only for the delay zones Default is 15s set the siren sounds time when the panel alarms it could be set within 0 3008 default one is 60s Timed auto arm disarm group auto arm disarm time could be set Press to get Alarm duration 66 Away arm with siren on it requires connecting an external siren The siren would sound once when user away arms the panel Low voltage warning tone the panel would sound beep when the registered sensor battery is in low voltage only for the wireless sensor has low voltage transmitting function 8 Delay arm with beep the panel would sound beep when the panel is delay arming During this time the panel would not alarm evenif the sensor is
9. l B only Test the sensor the panel would sound a dingdong whenever you trigger a registered sensor Password setting set the password of the panel the default one is 123456 Delay setting set the arm delay alarm delay time Alarm duration set the siren sounds time when the panel alarms Timed auto arm disarm set the auto arm disarm time Away arm with siren on the siren would sound when away arm the panel so that user could hear the arm sound in a distance Low voltage warning tone the panel would sound beep when the registered sensor battery is in low voltage Delay arm with beep the panel would sound beep when the panel is delay arming Main power fail alarm the panel would alarm when the main power goes out Doorbell zone period setting set the doorbell zone working in the set period Doorbell music setting choose the music played when the doorbell zone is triggered Gsm no signal warning the panel would sound if it detects there is no gsm signalfor 2min there is no warning tone by default Arm disarm with text report user could get the text report of the panel state Reset panel goes back to factory default setting Alarm history it shows the entire arm disarm and alarming logs Memory state it shows the number of registered sensor of each zone Alarm system menu detail explanation Alarm Setting Alarm number setting 6 group alarm numbers are programmable Alarm mode call te
10. larm setting Parameter setting Simple operation flow Insert the simcard to the slot of the back cover and push it down tight Turn the switch beside the simcard slot to ON to enable the built in battery Plug the adaptor the panel is turned on the screen lights Panel screen shows the time date Enter the current time in the sequence of hour minute 24 hours mode and then press the down key and enter thecurrent date in the sequence of year month date Then press ok key to save it tae Register the wireless remote sensor once received the product please test it first Because the accessories have registered already All the following operation are done in the disarmed state 6 Register remote Press key panel shows alarm system press key panel shows enter the password enter the default password 123456 it could be modified press press down key to choose wired wireless device press choose register wireless device press It shows trigger the wireless device press the disarm key of the remote it shows choose the zone choose the remote zone press to save it Test the registered remote In the disarm and non calling state press the arm key of the remote the panel sounds and display armed It means the remote is registered and could control the panel 7 Register door sens
11. n siren with external siren optional 11 4 2V 1000mAh rechargeable lithium battery lasts for 48 hours when power fails 12 Standard RS48 interface 64pcs node repeater expandable mode B Specification Wireless frequency Working conditions temperature 220 601 humidity 9 5 Recording duration 180seconds It could match all the following sensors 1 2 3 4 Encoding IC 2262 2260 timing resistor 4 7M Encoding IC 1527 timing resistor 430K CPU encoding conform to the above 2 rules The wireless transmitting frequency is same as that of the panel Panel interface introduction gsm antenna Navigation key LCD Arm Enter key Disarm Numeric key Backspace a Keyhole Stes ie ysiem Key explanation Navigation left right key left inbox right write text Navigation up down key up missed call down answered call O key enter the menu and confirm Ese key cancel delete and backspace key Arm key press it to away arm long press it to stay arm Disarm key Press it and then input the password to disarm key long press it to switch between audible silent mode in the SMS writing mode press it to switch input method key during words input it is used to access punctuation marks during time input it is used to access colon Numeric key it is to input numbers Arm disarm state gsm signal Battery indicator China mobile Time date Menu back and ESC key corres
12. nsteverseeeet 9 8 Zone explanation and text command demas ko wos 10 9 Recordingand record binding e145 11 10 Wired ports binding Wilh 20 6 ei tesis saae seed dae E E 11 41 Relay output binding with zones rere 11 12 Wireless detectors triggering 2 2 eer sas 12 13 Alarm handling and 6 ssa g bod 12 t4 Installati n and usage 1 665 sass sav Sts 12 Back cover Quick reference Function and specification Function Dot matrix Icd display chord ringtone voice record and menu operation 16 zones 16 wired 240 wireless connections 16 NC NO output binding with zones 6 alarm numbers auto dial and or group text are optional gt A wN Alarm number and text content are programmable on the panel gi Record different voices for different zones or alarms the voice would be auto played when alarming 6 Remote control remote speak remote arm disarm remote turn on off the siren 7 Exclusive sensor or button doorbell zone which could work with various sensors and buttons with exclusive chord ringtone 8 Timed auto arm disarm 9 Main fails alarm 10 Built i
13. or pir Press lt gt key panel shows alarm system press key panel shows enter the password enter the default password123456 it could be modified press press down key to choose wired wireless device press choose register wireless device press lt shows trigger the wireless device trigger the door sensor or pir to transmit the wireless code to panel panel gets the code and it shows choose the zone choose the zone number press save it Test door sensor Use the remote to arm the panel and then trigger the doorsensor you have registered Panel alarms and activates the siren and that means the sensor is registered Alarm number setting alarm tel number when the host sound an alarm it will send sms to tel number that you setted before or dail a call to notify the user 8 Alarm number is the number that panel would auto dial or text when it alarms Press key panel shows alarm system press key panel shows enter the password enter the default pass word 123456 it could be modified press and choose alarm setting press and choose alarm no setting press Ee and it shows alarm no 1 enter the number you plan to set press to save it Zone explanation Remote control zone this zone is for remote control only Xero deere it is an independent zone for the sensor or button working asthe doorbell Use
14. pond to the menu and back on the screen disarmed armed stay armed Power input Detector power input Relay series connection Rs485 MODBUS only for model B INO IN15 wired input Siren Battery switch 7 Power connection Battery socket he battery switch is default off to save power please turn it on otherwise the panel could not work when power fails SC 6 6 Fokaal The relay output could work as a switch to control external device like lights etc max load is 1000w How to insert the sim card 1 Slightly press it down and push the slot to the right 4 Push down the slot 5 Push it down and a slight sound could be heard siren Input voltage 5v DC Horn level 110db Working current 180ma Power supply Input voltage 220v AC Input frequency 50 Hz Output voltage 12V DC Load current 2A Accessories Transmitting LED y Away arm 5 Disarm Stay arm SOS N t remote Working voltage 12V DC Static current 0 uA Working current lt Transmitting frequency 315 433MHz Transmitting distance 50m in the open air Away arm arm all the sensors Stay arm arm all the sensors in the external zones SOS ask urgent help Disarm disarm the panel or stop the alarming Working temperature 10 C 75C The above product picture is only for illustration the actual product may have nothing to do with the
15. r could set a time period for the zone andduring the set period once the sensor button of this zone istriggered it would make a doorbell sound 24 hours zone sensor in this zone would alarm either in armed or disarmed state It is armed 24 hours Alen ElpA Gl Sensor in this zone would alarm in armed state the sensors in this zone would not alarm when user stay arms the panel They only work when user away arms the panel BE Wars Sensor in this zone would arm after a preset delay timer so that user has enough time to leave the area Also when the user comes back the sensor would not alarm immediately so that the user has enough time to disarm the panel Metal GSM Alarm System User Manual Thanks for choosing our product please kindly read this manual carefully before installing it Overview OMCHOMENG specication Esse recet gh dhe ae dit Genes ees 1 2 Panel interface satus 066 245 4 sade eee eH eee e 2 S ACCESSOrY INMOUUCHON erres assai dow a Res 4 A Accessory ifiStallation 6 det ne a 6 5 Alarm system menu aNd esei cs tus Rss T 6 Alarm system menu explanation serstaka ss sukak aami aa a ede 8 7 Telephone system menu introduction lt lt n i0ccex
16. sor there are 4 screws under the product use your handor a conductor short circuits any of the 2 diagonal screws theled flashes and that means it is triggered Wireless temperature sensor Press the OK key the one in the middle ofthe 3 and hold it for 2 seconds the number on the Icd slightly flashes and that means it is triggered and transmitting code Trigger the wireless sensor means the wireless sensor transmits the wireless code The panel could receive and save this code After that the sensor could work with the panel Different sensors have different triggering ways Alarm handling and remote operation Alarm handling when the panel alarms it would auto dial the preset alarmnumbers in sequence Once user gets the alarm call he could pick up the phone and press key to confirm the alarm and hear the recording Then panel would not dial the next numbers If user does not press panel would continue to dial the next number and it would repeat the whole process in 3 circles User could press 9 to rehear the recording After the panel alarms user picks up the phone and then he could remotely control the panel by the keys on the phone Press 1 to listen in press 2 to speak press 4 to turn off the listen in and speak press 3 to sound the siren press 6 to turn off the siren press 7 to arm press 8 to disarm press 9 to hear the alarm recording again Press 5 to hang up User also could dial the panel number and remote
17. tector detects unacceptable levels of combustible gas it will transmit an alarm signal to the control panel and also activate its own integral local siren It could also work 3 Wired wireless shock sensor The shock sensor is used to detect the strength of the shock Fix the shock sensor on the object you want to protect and it would alarm and transmit the alarm signal to the control panel when the strength of the shock exceeds the preset value 0 Accessory Installation 1 Door sensor install door frame Well Make sure the space between is less than 10mm Mount the wireless transmitter and the magnet respectively on the door frame and the door usually in the upper edge of the door and frame Clean the position where installthe door sensor Stick the double sided tape with adhesive or screw them firmly The transmitter and magnet should be parallel and the interval distance less than 10mm Pir sensor installation XE EAJ Do not face the cold and heat directly Do not face the sunshine directly Do not install it near the electric cable DL L Do not face the airflow Do not face the fluttering curtain directly Do not install it outdoors 1 Position A is better than B according to the performance of infrared 2 Put the sensor at position A where it could protect doorway aisle and window a wider rang
18. triggered Default delay timer is 15 seconds Main power fail alarm the panel would alarm and send text to user when the main power goes out this is default off Please remember to turn on the battery switch Doorbell zone period setting set the doorbell zone working in the set time period 3 periods could be set Once this time is set the panel would make a dingdong sound when the sensor in the doorbell zone is triggered during this period Press to get Doorbell music setting choose the music played when the doorbell zone is triggered use up down key to choose the music Gsm no signal warning the panel would make a 2mintues long sound if itdetects there is no gsm signal for 2mintues DC Arm disarm with text report user could get the text report of the panel state E g if user uses the remote arm the panel afterthat he could get a text remote no 2 arms Reset Press this to make panel go back to factory default setting but it would not delete the registered device Event log Alarm history it shows the latest 20 events happened in the panel it includes all the arm disarm and alarming information with zone number detector no and time stamp Memory state check the registered sensor numbers of each zone Telephone system menu overview Phone book Text Call Tools Time date Lang Chinese English phone set Preferred input method Airplane mode Lcd backlight set Network setting Securit
19. xt text and call or local siren only It is default to text call the first no if you need to text call all the numbers please activate the group message Zone text setting a User could edit the text content for each zone b The default text is in this format zone 5 3 alarm it means the sensor 3 of zone 5 is alarming Alarm voice setting a The voice would auto play when alarm b 180 seconds voice could be in multiple segments each zone could have a different recording Press record key to start recording and then backspace key to save it Then you could bind the recording to each zone When alarm panel would first play the recording of the user address and then that of the alarm zone Sounder silent alarm setting user could choose to turn on off the inside siren when alarm Group message Enable this function is to make panel send text to all the alarm numbers when alarm The default setting is to send text to the first no only Wired wireless device setting Enable the wired zone The panel has 6 NC wired connections when they areopen panel would alarm Each wired connection could be enabled or disabled separately Register wireless device It could work with 16pcs remotes It has 15 zones and each zone could work with 16pcs sensors Trigger the sensor you plan to register panel would get its code and you choose a zone to save it if the sensor is already registered trigger it and the panel would show its numb
20. y setting External link Factory reset Default password 1122 Phone profile Zone explanation and text command Zone explanation Remote control zone it is an independent zone for the sensor or button working asthe doorbell User could set a time period for the zone andduring the set period once the sensor button of this zone istriggered it would make a doorbell sound Beyond this period it would not work even if being triggered this zone is for remote control only Doorbell zone Normal zone Sensor in this zone would alarm in armed state 24 hours zone sensor in this zone would alarm either in armed or disarmed state It is armed 24 hours It is suitable for smoke sensor gas sensor and water leakage sensor etc Delay zone Sensor in this zone would arm after a preset delay timer so that user has enough time to leave the area Also when the usercomes back the sensor would not alarm immediately it would also allow user some time to enter the premise without triggering the alarm The sensor in other zones would not be subject to this e g we normally set the door sensor in the entry door to delay zone Whenuser goes out press the arm key the door sensor has 15seconds delay souser could go out during the 15 seconds without worrying triggering the alarm The door sensor would be armed after 15 seconds When users comes back the door sensor is triggered and would not alarm immediately it would wait 15s before it alarms

Download Pdf Manuals

image

Related Search

Related Contents

Mode D`Emploi Adventure 3  Albrecht DR 56 - ALBRECHT Audio  MANUAL DE OPERAÇÃO E MANUTENÇÃO DE ESTAÇÃO    AEG 1263 User's Manual  New Orion Star A210 Series Benchtop Meter User Manual  M2-A Agitatore magnetico riscaldante analogico  Process and Programming Challenges in Producing  Télécharger notre plaquette au format pdf  Reference  