TDAS PRO Timed Output Module Hardware User`s Manual
Contents
1. If you need to control larger loads or have questions about your specific application please contact DTS Contact Closure Mode An opto coupler is either turned on or off at the time programmed in the TOM setup screen of the TDAS software The output is in a high impedance state while the module is idle The TOM setup screen allows you to choose normally open or normally closed Whichever polarity you select the output will assume the normal state when you arm the system The output returns to a high impedance state when the data collection time window has passed 0 5 Volt logic Mode Each channel has a DC DC converter and opto couplers that generate fully isolated and current limited 0 5 volt signals The output is in a high impedance state while the module is idle The TOM setup screen allows you to choose 0 gt 5 volt or 5 gt 0 volt Whichever polarity you select the output will assume the normal state when you arm the system The output returns to a high impedance state when the data collection time window has passed Squib Resistance Test Each TOM unit contains four independent squib resistance measurement circuits These circuits connect a regulated 1 mA current source to each squib connector and accurately measure the voltage drop across any connected loads The useful measurement range is 0 2 to 9 5 ohms The TOM can only take resistance measurements when the Safety Switch is in the ARM position sin
2. Note The XX in the part number above specifies the collet diameter Based on the size of wire cable you will be using the representative can give you information about the options available when you place your order Some of these connectors may be provided with your module You may also need to purchase one or more of these for use with your system You can purchase additional connectots as desired Connectors can be purchased directly from Lemo USA www lemousa com or through their distributors The web site has information on distributors in your area 14 6 Pin Squib Output Connector channels 1 4 Squib Squib Sense ID ID Sense 19 Pin Digital Output Connector Digital Out Ch 1 Digital Out Ch 6 Digital Out Ch 7 Digital Out Ch 6 Digital Out Ch 1 Digital Out Ch 7 Alarm Output Digital Out Ch 2 Spare Digital Out Ch 5 Digital Out Ch 8 Alarm Output Digital Out Ch 5 Digital Out Ch 2 Digital Out Ch 4 Digital Out Ch 3 Digital Out Ch 3 Dioital Ont Ch 4 Digital Out Ch 8 3 Pin Event Connector Event Event All connectors shown in panel view 15 15 pin Interface Connector All module functions are controlled through the 15 pin connector The pin designa tion and functions are listed below Se ee turn off Has a 15 second time constant before turn off occurs Fault output Used
3. TDAS systems are rated for and tested to greater than 100 Gs 12 mS duration in all axes TDAS PRO equipment can be mounted directly on a vehicle sled or other dynamic testing device Temperature Rating Your system has been tested for full functionality with a case temperature of 70 C The actual case temperature will be affected by four primary factors 1 Ambient air temperature and airflow 2 Sunlight exposure 3 Sensor load and 4 Length of time armed Always shield the units from exposure to direct sunlight and avoid situations where airflow is restricted If two or more of the primary factors will cause high case temperatures the airflow created by a small fan will increase heat transfer by a factor of 3 to 5 When in doubt measure the case temperature and take whatever steps are necessaty to reduce the case temperature to less than 60 C for continuous operation It is unlikely that the units will be damaged by excessive heat because power is internally limited by self resetting thermal fuses the units will simply shut down when they get too hot Power Connections and Considerations A good power source is of paramount importance TDAS PRO systems should be powered from a fully charged 12 volt battery or a high quality power supply with a nominal output voltage of 13 8 volts 12 14 volt range Internal Module Back up Batteries Each TDAS module contains a 9 6 volt 110 mAHr NiCad back up battery sufficient to sustain fu
4. be greater then 10 000 ohms and drop to below 4 000 ohms Open collector or open drain connections with a voltage rating of 20 volts or greater work well If connecting to the TOM through a MID or a signal module device never apply trigger voltages to the Event input without consulting DTS It is quite easy to convert a voltage signal into a simulated contact closure for TDAS We often use N Channel FETs CAUTION Do not apply external voltages to the EVENT inputs this could result in damage to the unit A simple FET switch can be used to convert a voltage signal to an appropriate contact closure Please contact DTS if you need assistance 12 Review of Recording Modes TDAS systems allow the use of circular buffer or recorder mode data collection e In circular buffer mode the event input triggers data collection starts all timers i e fires squib channels with pre programmed delays and durations and is used to mark zero time T 0 e In recorder mode the event input is used to start all timers and mark T 0 Squib Data Recording Functions Each TOM contains eight high speed 16 bit data recording channels complete with anti alias filters These filters are the same as those supplied with TDAS PRO Sensor Input Modules Each Channel has a fixed 8 pole Butterworth filter Standard 3 dB knee point of 4 300 Hz Others available on request For lower sampling rates a 5 pole adjustable Butterworth filter is set under sof
5. ea 11 Safety Protocol acas oi EE d a i 11 VEE AVE RE sk a MR RS N EE aaa d 11 Event LED UE ceeace poat atena oi noii da EK eiii iiaii ER ge Gen de egg ee iie ieee dear 11 Review of Recording EE EE RE N ae 12 Squib Data Recording FUNCTIONS sees sesse see EE EA EA EA Ee ee se 13 Sk Current PERDE soe GEE GE acea GE sede as Be ca Geta 13 Sgub Voltage Measurement RE pla a tag aaa ad tau 13 Chann Number MA AE ER OE ea taia aii 13 PDD CTI IR EA oo panda elada lieu dinainte da tal a OAC orei OE EL OO aa n a tina pa e 13 pin Intera IR LAE EA EE A Introducing the Timed Output Module Each Timed Output Module TOM is a self contained timing system with 12 independently programmable timing channels Four channels have programmable drivers for firing pyrotechnic initiators commonly used in air bags and safety belt pre tensioning devices Eight channels are called Digital Outputs These are fully isolated 20 mA drivers that may be used to generate switch closure or logic signals for controlling various devices such as cameras strobes braking systems etc TOM units may be used side by side with other TDAS modules such as Sensor Input Modules SIMs Please read this entire manual before working with the hardware Summary of Module Features e Built and 100 tested for 100 G dynamic test environments e Four completely independent energy delivery channels that may be used to fire air bag squibs or other pyrotechnic devices e Three
6. the back up battery was fully charged before testing Typical backup life under normal circumstances will be at least five minutes Power Consumption and Management When the module is initially powered all output circuits are in a shutdown state When the user runs a test set up the software automatically energizes only those channels that have been programmed in the Test Setup File TSF file see the Software Manual for information on the Test Setup File The current draw per module will increase from 350 400 mA at idle to as much as 800 mA when all channels are in use and the system is fully armed Once the system has been armed for data collection all circuits remain in a full power state until the system finishes storing data After the storage mission is complete the module automatically returns to a reduced power state It takes 20 30 seconds after the end of the data storage time window for the module to return to the idle state which then allows communication and download Timing Functions Each TOM contains a total of 12 timing channels which are programmable in 0 1 mS increments The timing generator uses a very accurate crystal time base There ate two time related settings for each channel in the TDAS Software DELAY is the interval between the Event signal and the beginning of the output pulse i e a switch closure at impact or T 0 This interval may be set from 0 0 ms to 99 000 mS 99 Seconds DURATION is the ti
7. 2 Q load AC Capacitive Discharge The output connector is alternately switched between the charged capacitor and a short through low resistance solid state switches This creates a high current square wave that begins and ends at the programmed times The frequency of the output driver is adjustable from 12 KHz to 120 KHz via a setting in the TDAS initialization file Edit TDAS IND DC Constant Current The charged capacitor is connected to the output connector through a solid state regulator Active feedback is used regulate the output current to the programmed value Current may be set between 1 0 and 4 0 Amps in 0 1 Amp steps Since the energy for the output pulse comes from the charged capacitor the duration that each TOM channel will be able to deliver the selected current is dependent upon the resistance of the connected load and the current setting The following table shows the typical maximum pulse width at the set current Current Setting With 2 Q Load With 1 O Load 1 0 Amp 44 0 mS 48 0 mS 2 0 Amp 17 5 mS 22 0 mS 3 0 Amp 9 2 mS 12 8 mS 4 0 Amp 4 8 mS 8 0 mS What do the LEDs mean Each TOM has 6 LEDs on the connector panel The functions of these indicators ate as follows BAT Three color LED that blinks e Green OK e Yellow Power is marginal Able to complete test but would not be allowed to start testing e Red Critically low power Do not test e Off Module is off or all power
8. TDAS PRO Timed Output Module Hardware User s Manual CA mare 2 Ee ARME tomoos December 2002 Rev 1A PDTS hone 1562 493 0158 e Fax 1 562 493 3158 www dtsweb com Table of Contents Introducing the Timed Output Module 4 Summary of Module Features vciieccscossesetsnvsecasccvsossoesscstsensseossveuventeesesenieveroncsers 4 Basic Care and Handling noii ieder de iap de ee dok od doit sell ta 4 BE IRA GEN OE gas a pia ia ia aaa a c lu 5 Temperature Rating orrera OT RE KO aa re e a a e e 5 Power Connections and Considerations reersssessersscssssesscseseessccssseessscseseessseseees 5 Ee ME NO DA OR dl pia n vea ce ada 5 Back up Battery Operation L EE n pl a iza ata lata 6 Power Consumption AE EN KO N a pie 6 Timina aie se po cinap do aa nad oi rapa aa cae 00 da 0 0 aude Da bataie 7 Squib Channel Overview ga s banat ca orase ta at and tatea cad dna ceata 7 IDG Caprese ID LE OE a i ies py a d au 20 a 7 ee VEN ICHAT EE EE o a aa cada a BR aa Z Bed EA RR RE AE ada pa RE N 8 Digital Channel Overview sesse esse ese ees Ge Se Rees de Go op ae de dee ee 8 Contact Closure VLOG ics caca OE RE ela Dita lia e DEERE Ue e Bau 9 OVA OIE ooe Modena ataca ct ea a de dia a i a las 08 9 SQUID Resistance TESE sees dees ede ese bedes Gee eek Ged Ge Ee eo Re Ee dese Ro GEE Ee 10 Lest Atticle ID Sn ts closes ee Ol a 7 Ea Ge aa aa He 10 Safety and Arming Functions series sesse esse sek poate dadea seed aoleu elodia atitea
9. ant since the Event signal typically causes air bags or other potentially dangerous devices to activate 11 The TDAS software allows you to choose the Event logic by editing the TDAS initialization file Edit TDAS INI The options are summarized as follows e Rack Bus Only Event comes from the Rack Event connector through the rack bus e TOM Only Event comes from the Event connector on the TOM panel e TOM and Rack Both signals must be present to fire squibs e TOM OR Rack Either signal may be used to fire squibs Whatever method you implement please exercise great caution in implementing an appropriate and safe method for supplying the event signal to the TOM modules WARNING Unreliable intermittent or inadvertent event signals could cause the TOM unit to fire air bags or other potentially dangerous devices when a user is not expecting it or prepared Once the system is armed please be very careful around TOM units and the devices to which they are connected Event Input Characteristics The event input on each rack or TOM panel requires a dry contract switch closure that will cause the resistance of the event input to drop to less then 4 000 ohms These inputs were specifically designed for use with contact switches in harsh environments The open circuit voltage is between 15 amp 20 volts DC A digital output card or PLC may be used to supply the event signal to the system but the nominal open circuit impedance must
10. ce the TOM applies a short across the squib output connectors when the switch in the Safe position The output of each squib resistance measurement circuit drives two other circuits 1 A 12 bit A D converter This allows the software to record the connected squib resistance to within about 0 1 ohm accuracy during the setup routine prior to arming 2 A window comparator that constantly monitors the squib resistance of all programmed channels once the system is armed If any squib resistance falls outside the window set in the TOM setup screen the module will generate a system fault so that a test may be aborted if desired The TOM is capable of taking 4 wire resistance measurements This feature is enabled by removing jumpers inside the module and by properly connecting the and Sense leads on the squib output connectors Please contact DTS if you need to implement a four wire resistance measurement scheme As delivered the sense leads do not need to be connected Test Article ID TOM modules contain an automatic ID system that works with Dallas Semiconductor Silicon serial number devices Simply connect DS2401 devices to the ID pins on the squib connectors and use the available software tools as desired 10 Safety and Arming Functions Safety Protocol TOM modules employ a three tiered safety protocol In order to activate the squib drivers the following steps must take place 1 The software must receive setup an
11. d arming commands from the user in the correct sequence 2 The Module firmware must load a safety key bit pattern into the fire controller 3 The Safety Switch must be cycled from Safe to Arm at the correct time as instructed by the software When the Safety Switch is in the Safe position the squib outputs are shorted Warning Systems The Digital output connector includes two pins that are identified as Alarm Whenever the internal squib voltage source is energized or the module is in the arming stage this warning output goes high 5 volts 20 mA DTS STRONGLY RECOMMENDS that this signal be used to turn on a high visibility facility warning device to warn technicians to stay away from any connected devices such as air bags WARNING DTS STRONGLY RECOMMENDS that users of TOM Modules implement an appropriate high visibility warning system and safety protocol to keep people away from potentially dangerous devices such as air bags Event Input TOM modules contain two separate input circuits that may be used to generate the internal Event signal that starts all of the timers One path is through the 15 pin connector on the back of each Module and works the same as TDAS PRO SIMs The other path is through the Event connector on the connector panel of each TOM This is a fully isolated ESD protected contact closure input similar to the input on TDAS PRO Racks The source of the Event signal is extremely import
12. energy delivery methods may be chosen under software control 1 Capacitive Discharge 2 Constant Current 3 AC Coupled Discharge e Eight additional timing channels with fully isolated switch emulation or logic level outputs e Standard data recording channels to record voltage and current waveforms e Built in back up battery for safe operation even with loss of primary power e Simple 15 pin interface connector e LED indicators for power event and status of each squib fire channel Basic Care and Handling DTS systems are designed to be as simple to operate as possible but it is important that you carefully follow recommended procedures in order to ensure maximum reliability TDAS PRO modules are precision devices designed to operate reliably in 100 G dynamic testing environments for many years Though resistant to most external environmental conditions care should be taken not to subject the unit to harsh chemicals submerge it in water or drop it onto any unprotected surface When transporting the unit treat it as you might a laptop computer and you should have no problems We suggest that you always place the unit in the padded carrying case originally provided with your system when it is not in use WARNING Electronic equipment dropped from desk height onto a concrete floor may experience as much as 10 000 Gs Under these conditions damage to the exterior and or interior of the unit is likely Shock Rating All
13. ll power operation for a short time if main power is lost Module back up batteries are automatically charged whenever 12 14 volt external power is connected to the module This can be accomplished by applying power to the module through a TDAS PRO rack Module Interface Device MID or a single module device cable The module does not have to be turned on in order to charge the battery With the module installed in a rack module back up batteries are automatically charged whenever the TDAS PRO tack smart charge feature is activated by connecting a 13 8 volt power source 13 2 15 volts to the rack main power input The internal battery must be charged for several hours in order to take advantage of the backup capability This is generally not a problem since module batteries are charged whenever the TDAS system is connected to an appropriate power source and turned on Remember that all batteries need to be properly cared for In the case of module batteries periodically discharging the batteries by leaving the system on with no external power then re charging will help ensure maximum battery life DTS tests the internal battery when the units come in for calibration When the capacity falls to a certain point the battery is replaced as part of the calibration Back up Battery Operational Life Actual useful back up life will depend upon the number of channels in use the mode the digital output channels are set to and whether or not
14. me window during which the output signal will be active This interval begins at the end of the delay period In the TDAS Software TOM setup screen you will find a Limit Duration button If this button is not active the output driver will turn on and stay on for the entire duration on the pre programmed data collection time window If the Limit Duration button is activated the duration parameter may be set from 0 2 to 25 5 mS for the four squib driver channels The Digital output duration may be set between 0 2 mS and 1 600 0 mS Remember that in all cases all channels may be active only during the preprogrammed data collection time window This means that the Post Event data collection duration must be greater than the longest duration output event on any squib or digital output channel Squib Channel Overview Each TOM unit contains four independent squib driver channels Each of these channels includes an energy storage capacitor and three different energy delivery circuits which may be configured on a per channel basis from the TDAS software When you arm the system using the software the energy storage capacitor in each programmed channel is charged to approximately 16 volts Energy delivery modes are as follows DC Capacitive Discharge The charged capacitor is connected to the output connector through a low resistance solid state switch at the preprogrammed time Typical peak output currents are approximately 7 Amps with a
15. sources are off e Blink rate Normally about 1 Hz Very fast or very slow blink rates indicate a problem with internal power supplies T 0 Red LED Indicates that Event was received via Rack bus or Tom Event input This LED latches and must be cleared through software Checking system status clears T 0 LEDs Squib Indicators one per channel Three color LED Normally off when the module is idle These indicators only come on between the time the system is armed and when the system is downloaded Pre Test e Green Channel Armed and Squib is within resistance tolerance limits e Yellow Channel Armed but Squib resistance is out of tolerance When this occurs a system fault is generated but the test may proceed e Off Channel not armed Post Test e Red Channel triggered and squib is now open e Yellow Channel triggered but squib is still showing continuity caution Digital Channel Overview Each TOM unit contains eight independent digital output channels Each of these channels is fully isolated using a DC DC converter and opto couplers These outputs may be configured on a per channel basis from the TDAS software These channels are not powered and remain in a high impedance state until you run the TDAS Software and arm the system If your device requires a certain signal level when the TDAS is not powered you may have to use pull up or pull down resistors as appropriate Remember that these channels are limited to 20 mA
16. to indicate a fault condition while the unit is armed and waiting for event Monitors power A D conversion and event circuits High speed data transfer clock output Used for synchronizing high speed data transfers to a TDAS PRO rack when using Ethernet communication Slot program bits Pin 10 bit1 9 bit2 8 bit3 Active low by connecting to power ground All open slot 1 all low slot 8 Serial communication transmit line 0 5 volt UART 38 4K on boot up Redundant memory back up power input typically 3 3 volts from rack 13 Serial communication receive line Also functions as the Start Record input in a TDAS PRO Rack 0 5 volt UART 38 4K on boot up High speed data transfer output Used to quickly download collected data files to a TDAS PRO rack when using Ethernet communication Event often called T 0 Logic low or contact closure with respect to power ground This input may be used in two ways e In circular buffer mode this input initiates storage of data AND starts timer channels AND is used to mark zero time T 0 In recorder mode this input is used to start timer channels AND mark T 0 only 16
17. tware control as needed for any of the available sampling rates Two data recording channels are dedicated to each squib These are configured as follows Squib Current Measurement Each squib channel has a dedicated current shunt and amplifier that converts the squib current into an accurate voltage This signal is automatically recorded for all programmed squib channels There are no choices to make here Squib Voltage Measurement There ate two options available which are chosen in the Edit TDAS INI section 1 Record Voltage means that the output voltage to the squib will be recorded 2 Record Initiation means that the timer drive signal will be recorded Channel Numbering The TDAS software automatically assigns channel numbers in the 900s to all squib channels It also applies some generic channel labels 13 Appendix TOM Connector Information Each TDAS PRO TOM has the following panel connectors e Four EGG 2B 306 CLL Lemo one per squib channel e One EGA 2B 319 CLL Lemo 8 digital outputs and warning signal e One EGG 1B 303 CLL Lemo fully isolated event input e One locking switch safe arm The pin designations for the Lemo connectors are illustrated on the following page Respectively the corresponding mating Lemo connectors cable side are e FGG 2B 306 CLADXX Lemo one per squib channel e FGA 2B 319 CLADXX Lemo 8 digital outputs and warning signal e FGG 1B 303 CLADXX Lemo fully isolated event input