IDS816 User Manule 70028301 C Ver 200
Contents
1. 1 New User Name 7 1 2 Enter the User Program Mode as per steps 1 5 of 9 2 Press the 1 key followed by the key to select programmable option 1 The Ready and Armed indicators will flash simultaneously User Names are displayed as the Zone Number by default Edit the ZONE NUMBER so that it reads the correct User Name To confirm the entry press The MODE key can be used to move the cursor to the right whilst the F key can be used to move from right to left Further codes may be added by repeating step 3 above IDS816 USER MANUAL NO 700 283 01C ISSUED FEB 2005 VER 2 00 9 3 3 Option 2 Edit a Selected User Code Hold Master Code 2 Old Code 7 New Code 7 1 Enter the User Program Mode as per steps 1 5 of 9 2 2 Press the 2 key followed by the key to select programmable option 2 The READY and Armed indicators will flash simultaneously 3 Enter the USER CODE which is to be edited followed by the x key 4 The READY indicator will flash and the AWAY indicator will be illuminated 5 Enter the NEW CODE followed by the key 6 The READY and ARMED indicators will flash simultaneously 7 To edit other codes repeat steps 3 5 8 Press the key to exit the User Program Mode 9 3 4 Option 3 View a User Code Slot Number Hold Master Code 3 User Code View the Slot number via the zone LED s
2. 1 2 5 6 Enter the User Program Mode as per steps 1 5 of 9 2 Press the 3 key followed by the x key to select programmable option 3 The READY and ARMED indicators will flash simultaneously Enter the User Code followed by the x key The READY indicator will flash and the AWAY indicator will be iluminated The USER CODE slot number will be displayed by the Zone indicators in binary format See table 2 Press the key to exit the User Program Mode Reading Binary Numbers All values will be displayed by the zone indicators in binary format Only binary values to the value of 8 are used See table 2 IDS816 USER MANUAL NO 700 283 01 C ISSUED FEB 2005 VER 2 00 15 Table 2 Values Represented by each Zone lndicator Zone 2 2 Zone 6 2 Zone 3 4 Zone 7 4 Zone 4 8 Zone 8 8 Binary values for Zones 1 4 are indicative of single unit values whilst binary values for Zones 5 8 are indicative of units of ten For Example Assume zone indicators 1 2 and 5 are illuminated Units are represented by the sum of Zone 1 and Zone 2 i e 1 2 and tens of units are represented by the value of Zone 5 i e 1 Thus the value indicated by the illuminated LED will be as shown as in the example below Zone 1 1 Zone 5 1 Zone 2 2 Binary Value 3 Binary Value 1 Thus the binary value of the illuminated zones is 13 9 3 5 Option 4 User Code Prope
3. 14 Changing a Partition To change partitions tne keypad must be a global keypad 1 2 Hold MODE until the keypad beeps Press 1 followed by the partition number 24 IDS816 USER MANUAL NO 700 283 01C ISSUED FEB 2005 VER 2 00 If the keypad is left for 20 seconds it will beep and default back to the default 15 Remote Telephone Access The IDS 816 Alarm Panel has a secure remote telephone interface which allows a user to arm disarm to bypass unbypass zones and to set programmable outputs via a phone line A user accesses the remote dial in interface by dialling the alarm panel with a DTMF enabled phone To access the remote dial in interface dial the alarm panel and wait the number of rings programmed the default number of rings being 15 or use the fax defeat function The panel will answer and transmit handshake tones consisting of a high pitch tone for two seconds followed by a lower pitch tone for one second Within twenty seconds of the panel transmitting the handshake tones enter a valid user code on the DTMF enabled phone If a user code is not entered or if the user code is invalid the panel will release the line If the user code is valid and telephone access has been enabled the panel will give a single confirmation beep indicating that the user has gained access to the remote interface If no key presses are detected for twenty seconds once access has been gained to the remote interface
4. 4 The alarm will arm in the away mode Note lfaremote control is used it is advisable to have the siren toot on arm function enabled 4 5 Auto Arming The panel can be programmed to automatically arm itself at a pre programmed time Should the premises be occupied at the time of auto arming a valid USER CODE entered during the pre arm delay will cancel arming The pre arm delay is signalled by an exit beep 5 Disarming the Control Panel 5 1 How to Disarm with a User Code USER CODE To disarm the system enter followed by a valid USER CODE before the expiry of the entry delay 1 Enter the premises through a designated entry route Entering via any other route will cause an alarm 2 As soon as the entry exit zone is violated the entry delay will begin The keypad buzzer will sound for the duration of the entry period 3 Press the key and enter a valid USER CODE 4 Once the system disarms the ARMED indicator will extinguish and the keypad buzzer will stop sounding 5 valid user code has been entered by the end of the entry delay period an alarm condition will be registered 8 IDS816 USER MANUAL NO 700 283 01C ISSUED FEB 2005 VER 2 00 6 If the entry period is too short have your installer change the entry delay period Note f a strobe or flashing light has been installed and an alarm condition is registered the strobe will continue flashin
5. DI V 7 155 euni IDS816 User Manual MANUAL NO 700 283 01C ISSUED FEB 2005 VERSION 2 00 Contents 9 9 1 9 2 9 3 1 9 3 2 9 3 3 Introduction to the 8 16 4 Understanding the Keypad Indicators 4 Programmable 5 5 Arming the Control 8 5 How Away ARM i s i da a akad ed lava 5 How 6 6 7 How Guick Stay Arm Recommended Method 7 How To Stay Arm and Go eee 7 Key Switch or Remote Arming 8 AUO 8 Disarming the Control 8 8 How To Disarm with a 66 8 How To Disarm using a Key Switch or Remote 9 BYPASSING 65 9 How To Bypass a ZoNe isisisi anina 9 How To Un Bypass a Zone eee 10 Emergency Alarms ootoronnnnnnnn nn nn n nn 10 Fire ALANIS sauna EaR E aE 10 Panie 10 Medical Alarms u eee eee eee een 11 Duress Alarms eee eee een 11 Alarm Memory rronnnnnnnnnnnnnnnnnnnnn trne 11 User CodeS sss siis
6. CODE Leave via Entry Exit Zone Ensure that the READY indicator is illuminated If not check that all protected doors and windows are closed and that motion has ceased in areas covered by motion detectors If necessary close the front door IDS816 USER MANUAL 700 283 01 C ISSUED FEB 2005 VER 2 00 2 Press the key 3 Enteravalid USER CODE If an incorrect code is entered the keypad buzzer will beep three times Press the key and re enter the code 4 The ARMED indicator will illuminate and the keypad buzzer will sound for the duration of the exit delay Any bypassed zones will be shown by a steady illuminated zone indicator 5 Leave only via a designated exit route The panel will arm at the end of the exit delay Quick Away Arm Shortcut Key Hold down the 1 key until the keypad buzzer sounds If this function is enabled it is possible to AWAY arm by simply holding down the 1 key until the keypad buzzer sounds and the arming process begins Note f the partition is already STAY armed this key will initialise AWAY arming It is therefore possible to change directly from STAY armed to AWAY armed 4 2 Stay Arming Stay arming allows the user to monitor selected perimeter zones and bypass interior zones The user can remain within the premises with access to designated areas during the STAY ARM cycle Any zone which may be violated accidentally should be programmed as a buzz zone When
7. READY indicator will flash and the AWAY indicator will be illuminated Press any button on the new remote This will assign the new remote to the user code as entered in Step 3 Press the key to exit User Program Mode 9 Delete User Code Code known Enter the User Program Mode as per steps 1 5 of 9 2 Press the 9 key followed by the x key to select Menu option 9 The READY and ARMED indicators will flash simultaneously Enter the USER CODE to be deleted followed by the x key Further codes may be deleted by repeating Step 3 above After deleting the final code press the key to exit User Program Mode 10 Delete a User Code Slot known Enter the User Program Mode as per steps 1 5 of 9 2 Press the 1 key then the 0 key followed by the x key The ARMED and READY indicators will flash simultaneously Enter the SLOT NUMBER for the User Code you wish to delete followed by the key You can determine the slot number of a particular code by using programmable option 3 Further User Codes may be deleted by repeating Step 3 After deleting the final code press the key to exit User Program Mode IDS816 USER MANUAL NO 700 283 01 C ISSUED FEB 2005 VER 2 00 19 10 Stay Zones Stay zones are those zones which are bypassed automatically when the system is iSTAY ARMED To avoid triggering the alarm zones such as bedrooms which are protected by Passive Infra Red PIR detec
8. ZONE NUMBER 1 Bypassed zones are shown by constantly illuminated zone LEDs 2 Enter bypass mode by holding down the 9 key until the keypad buzzer sounds The away indicator will flash and the other LED will be extinguished 3 Press the number corresponding to the currently bypassed zone then press the key 4 The zone indicator will extinguish the zone is now active 5 Press the key to exit the bypass mode 7 Emergency Alarms 7 1 Fire Alarms F Hold down the F key for two seconds until the keypad buzzer sounds Ifthe F key is pressed until the keypad beeps approximately 2 seconds a FIRE ALARM condition will be activated The FIRE ALARM CONDITION can also be triggered by a smoke detector connected to an appropriately programmed zone s The siren will sound on and off repeatedly if programmed and the FIRE REPORTING CODE will be transmitted to the monitoring company To silence the siren enter a valid USER CODE 7 2 Panic Alarms P Hold down the P key for two seconds until the keypad buzzer sounds If the P key is pressed until the keypad beeps approximately 2 seconds a PANIC ALARM condition will be activated A PANIC ALARM can also be activated by any FIXED PANIC 10 IDS816 USER MANUAL NO 700 283 01C ISSUED FEB 2005 VER 2 00 button or REMOTE PANIC buttons Ifthe audible panic option has been selected the siren will s
9. premises and disarm the panel after a Stay Arm and go If the panel is Stay Armed and an entry exit zone that is also programmed as a buzz zone is triggered an entry delay will begin If itis not programmed as a buzz zone the alarm will be triggered immediately If the panel was armed using the 6 key Stay Arm and Go violation of the entry exit zone will always start the entry exit delay IDS816 USER MANUAL NO 700 283 01 C ISSUED FEB 2005 VER 2 00 21 11 1 How to Program a Buzz Zone 4 ZONE NUMBER Select the reguired Stay Profile See 10 1 2 Hold down the 4 key until the keypad buzzer sounds The AWAY indicator will flash to show that the panel is ready to program buzz zones 3 Press the NUMBER corresponding to the zone you wish to be a Buzz zone followed by the x key 4 Therelevant Buzz zone will be shown by the illuminated zone indicator Stay zones will be shown by flashing indicators A Stay zone cannot be selected as a Buzz zone the Stay status must be cleared first 5 Repeat step 3 until all the required Buzz zones are programmed 6 Press the i key to exit the buzz programming mode 11 2 How to Cancel a Buzz Zone 4 ZONE NUMBER Select the required Stay Profile See 10 1 2 Holddown the 4 key until the keypad buzzer sounds The AWAY indicator will flash 3 Press the NUMBER corresponding to the BUZZ zone you wish to
10. the panel will release the line Should the panel be programmed to report to your cellular telephone entering the user code in the delay between beeps will also allow access to the remote telephone interface If the phone in access has been setup to arm disarm only pressing the number of the partition allows the user to toggle the panels arm status A single beep indicates that the partition has armed a double beep IDS816 USER MANUAL 700 283 01 C ISSUED FEB 2005 VER 2 00 25 Table 6 Remote Telephone Operation indicates that the partion has disarmed 3 beeps indicates that the partition is not ready to disarm If the phone in access has been set up to access the full menu Please refer to the table 6 and select the required operation Operation Key Entry Panel Response Arm a Partition 1 1 PARTITION A Single Confirmation Beep indicates Partition armed successfully Three Error Beeps indicates Partition cannot be armed by user code or Partition not ready to be armed or a key entry error has occured Disarm a Partition 1 2 PARTITION A Single Confirmation Beep indicates Partition disarmed successfully Three Error Beeps indicates Partition cannot be disarmed by user code or a key entry error has occured Check Arm Status By Partition 1 3 PARTITION A Single Beep indicates Partition is Armed A Double Beep indicates partition is Disarmed Three
11. violated a buzz zone will cause the keypad buzzer to sound for thirty 30 seconds before sounding the siren Entering a valid User Code before the siren sounds will STOP the keypad buzzing and prevent the siren from sounding To provide greater flexibility the panel caters for the programming of two 2 different STAY PROFILES Each STAY PROFILE contains a unique combination of STAY and BUZZ zones which cater for a particular STAY ARM requirement For example PROFILE 1 might be used when the family goes to bed in the evening whereas PROFILE 2 is utilized while they watch television See 10 1 How to Select a Stay Profile 6 IDS816 USER MANUAL NO 700 283 01C ISSUED FEB 2005 VER 2 00 How to Stay Arm USER CODE Do not leave premises 1 Select the required STAY PROFILE See Section 10 1 on page19 2 Ensure that the READY indicator is illuminated if not check that all protected doors and windows are closed and that motion has ceased in the areas covered by motion detectors 3 Press the key 4 Enter a valid USER CODE If an invalid code is entered the keypad will give an error beep Press the key and re enter the USER CODE 5 DONOT open the front door If the front door is opened the system will arm in the AWAY mode 6 The ARMED indicator will illuminate and the keypad buzzer will sound for the duration of the exit delay 7 The AWAY indicator will remain extinguished 8 Any STAY zones shown by a ste
12. 00 283 01C ISSUED FEB 2005 VER 2 00 Table 1 User Programming Options Options Summary of Programmable Options Option O Allows for the addition of new user codes Option 1 Allows editing of the user name displayed by LCD keypads This menu is only applicable if LCD keypads are installed Option 2 Allows editing of a selected user code Note that the user code properties are not edited only the user code itself Option 3 Allows viewing of the user code slot number for a selected code There are 32 available user code slots Option 4 Allows editing of the user code properties for a selected user code This is a bit mapped menu Option 5 Allows the allocation of a selected user code to a designated partition s This is a bitmapped menu Option 6 Allows a user remote to be added Option 7 Allows the deletion of a selected user code For this menu the user code must be known Option 8 Allows the deletion of a user code using the user code slot number 9 2 How to Enter the User Program Mode BODT 7 Ensure that the panel is not armed Hold down the key until the keypad buzzer sounds The ARMED and READY indicators will flash alternately Enter a MASTER USER CODE The factory default is 1234 Should the MASTER USER CODE be defaulted to six digits it will be 123456 Press the key A valid entry will be confirmed by a long bee
13. 4 The relevant zone indicator will illuminate 20 IDS816 USER MANUAL NO 700 283 01C ISSUED FEB 2005 VER 2 00 Note Buzz zones will be shown by flashing indicators See Section 11 ABuzz zone cannot be selected as a Stay zone the Buzz status must be cleared first 5 Repeat step 3 until the selection of stay zones is completed 6 Press the key to exit the stay zone programming mode 10 3 How to Cancel Stay Zones 3 ZONE NUMBER x 4 Select the required Stay Profile See 10 1 2 Hold down the 3 key until the keypad buzzer sounds The AWAY indicator will flash to show that the panel is in the Stay Zone programming mode 3 Press the NUMBER corresponding to the STAY zone you wish to cancel followed by the key 4 The relevant zone indicator will extinguish 5 Press the key to exit the stay zone programming mode 11 Buzz Zones Violation of a buzz zone during Stay Armed will cause the keypad buzzer to sound for a period of 30 seconds during which time a valid user code must be entered If a valid user code is not entered during this period the system will register an alarm condition This feature helps prevent unnecessary false alarms Note lfan entry exit zone is programmed as a buzz zone violation of the entry exit zone when the panel is Stay Armed will cause the keypad buzzer to sound for the duration for the entry delay time This allows the User to re enter the
14. DS816 USER MANUAL NO 700 283 01C ISSUED FEB 2005 VER 2 00 IDS816 USER MANUAL IDS816 USER MANUAL NO 700 283 01 C ISSUED FEB 2005 VER 2 00 27 User Guide Guick Reference Add a User Code Change a User Code View a Slot Number Edit User Code Properties Allocate a User Code to a Partition Teach a Remote to a User Code Delete User Code by Code Delete User Code by Slot Number Master Code 0 New Code Master Code 2 Old Code New Code F Master Code 3 User Code View the Slot number via the zone LED s F Master Code 4 User Code 2 or 3 or 4 2 Duress 3 Arm to Disarm Code 4 Global Arm Disarm Code F Master Code 5 User Code Partition Number Master Code 8 User Code Press Tx Button Master Code 9 User Code Master Code 10 Slot Number Change Partitions Mode 1 Partition Number Select a Stay Profile Mode 2 10 1 Profile Number Program Cancel 3 Zone Number Stay Zone Program Cancel 4 Zone Number Buzz Zone Program Cancel 2 Zone Number Chime Zone Stay Arm and Go 6 Entry Exit zone must be made a buzz zone Bypassi
15. Error Beeps indicates a key entry error Bypass a Zone 2 1 ZONE A Single Confirmation Beep indicates that the zone was successfully bypassed Three Error Beeps indicates that the zone cannot by bypassed or a key entry error has occured Un Bypass a Zone 2 2 ZONE 7 A Single Confirmation Beep indicates that the zone was successfully unbypassed Three Error Beeps indicates that a key entry error has occured Check Zone Bypass Status 2 3 ZONE A Single Beep indicates that the zone is bypassed A Double Beep indicates that the zone is un bypassed Three Error Beeps indicates that a key entry error has occured Set Programmable 3 1 OUTPUT A Single Confirmation Beep indicates that the programmable output was set Programmable Output Status 3 1 OUTPUT Output Three Error Beeps indicates that a key entry error has occures A Single Confirmation Beep indicates that Pi 3 1 OUTPUT the programmable output is clear r 9 Three Error Beeps indicates that a key entry Output error has occured A single Beep indicates that the programmable output is set Test A Double Beep indicates that the programmable output is clear Three Error Beeps indicates that a key entry error has occured Hang Up o Telephone Line Released Three Error Beeps indicates that a key entry error has occured 26 I
16. adily illuminated indicator will be automatically bypassed 9 Ensure that you enter only those areas that are bypassed How to Quick Stay Arm Shortcut Key Hold down the key 5 for two seconds until the keypad buzzer sounds It is possible to STAY arm by holding down the 5 key until the keypad buzzer sound The panel will immediately arm into the stay mode without any exit delay 4 3 How to Stay Arm and Go Hold down the key 6 for two seconds until the keypad buzzer sounds This is a single key arm function which allows the user to STAY arm and leave the premises If a partition is already stay armed holding down the 6 key initiates an exit delay thus allowing the user to leave the premises without disarming At the end of the exit delay the partition will rearm in the same stay profile it was armed in before the 6 key was held down 1 Hold down the 6 key until the keypad buzzer sounds The IDS816 USER MANUAL 700 283 01 C ISSUED FEB 2005 VER 2 00 7 keypad buzzer will sound for the duration of the exit delay Only leave via designated exit route 2 Atthe end of the exit delay the ARMED indicator will illuminate and the AWAY indicator will remain extinguished All stay zones will be bypassed 4 4 Key Switch or Remote Arming If fitted 1 Ensure that the READY indicator is illuminated before leaving 2 Leave and close the door remembering to lock 3 Activate the remote or the key switch
17. at partition and entering a global code at the keypad of the disarmed partition will arm that partition 9 3 6 Option5 Assign User Code to Partitions 1 Enter the User Program Mode as per steps 1 5 of 9 2 2 Press the 5 key followed by the key to select programmable option 5 The READY and ARMED LEDs will flash simultaneously 3 Enter the USER CODE followed by the x key 4 The READY indicator will flash and the AWAY indicator will be illuminated 5 The partitions to which the USER CODEJ is assigned are displayed by the by the zone LEDs If zone LED 1 is illuminated the User Code can arm or disarm partition 1 If zone LED 2 is illuminated the User Code can arm or disarm partition 2 It is possible to program codes to arm disarm both partitions 6 To select which partitions the USER CODE may arm or disarm toggle zone LEDs by entering the ZONE LED NUMBER followed by the key 7 Repeat step 6 until all User Codes have been assigned to the correct partition s 8 Press the key to exit User Program Mode 9 3 7 Option 8 Adding User Remotes 1 Enter the User Program Mode as per steps 1 5 of 9 2 2 Press the 8 key followed by the key to select programmable option 8 The READY and ARMED 18 IDS816 USER MANUAL NO 700 283 01C ISSUED FEB 2005 VER 2 00 6 9 3 8 Option 1 2 9 3 9 Option 1 2 LEDis will flash simultaneously Enter the USER CODE followed by the key The
18. cancel followed by the x key 4 The relevant zone indicator will extinguish 5 Press the key to exit the buzz zone programming mode 12 Chime Zones The chime mode allows the user to monitor nominated zones while the system is disarmed The keypad buzzer will sound briefly when the nominated zone is violated the siren will NOT sound and no alarm condition will be reported EXAMPLE You wish to know each time someone enters and exits the front door If a Zone is programmed as a chime zone the keypad will beep each 22 IDS816 USER MANUAL NO 700 283 01C ISSUED FEB 2005 VER 2 00 time someone enters and exits the front door 12 1 How to Program Chime Zones 2 ZONE NUMBER Hold down the 2 key until the keypad buzzer sounds 2 The AWAY indicator will flash 3 To program a zone as a chime zone press the key corresponding to that zone followed by the key The zone indicator will illuminate 4 Program any other zones you wish to select as chime zones as per step 3 5 Press the key to exit the chime programming mode 12 2 How to Cancel Chime Zones 2 ZONE NUMBER x 4 Hold down the 2 key until the keypad buzzer sounds 2 The AWAY indicator will flash 3 To cancel any chime zones press the key corresponding to that zone followed by the x key The zone indicator will extinguish 4 Press the key to exit the chime pr
19. g after the siren has stopped sounding Entering a valid USER CODE will cancel the strobe 5 2 How to Disarm using a Key Switch or Remote 1 2 Activate the remote or keyswitch The system will disarm and the remote indicator if installed will extinguish If siren toot on disarm option is enabled the siren will give a double toot Bypassing Zones The term BYPASS is used to describe a zone that has been de activated i e violation of a bypassed zone is ignored and will not cause an alarm condition Once the system is armed it is not possible to bypass zones All bypassed zones will be automatically cancelled each time the panel is disarmed and must be re bypassed before the next arming 6 1 How to Bypass a Zone 3 4 5 Hold down 9 ZONE NUMBER To enter bypass mode hold down the 9 key for two seconds until the keypad buzzer sounds The Away LED will flash and all other LEDis will be extinguished Press the number corresponding to the zone you need to bypass e g the 2 key if you wish to bypass zone 2 then press the x key The relevant zone indicator will illuminate to indicate that the zone is now bypassed Repeat step 2 to bypass other zones Press the key to exit the bypass mode Note Panic Zones cannot be bypassed IDS816 USER MANUAL 700 283 01 C ISSUED FEB 2005 VER 2 00 6 2 How to Un Bypass a Zone Hold down 9
20. iate peripheral sensors and signalling devices 2 Understanding the Keypad lndicators Refer to the illustration on the inside front cover of this manual 1 ARMED lndicator Red Iluminated System Armed Extinguished System Disarmed Flashing Alarm Condition or Memory 2 AWAY Indicator Red Iluminated System Armed in Away Mode Extinguished System Disarmed Armed in Stay Mode 3 POWER Indicator Red Iluminated Mains Power is present Flashing Trouble Condition 4 IDS816 USER MANUAL NO 700 283 01C ISSUED FEB 2005 VER 2 00 4 READY lndicator Green Illuminated System is ready to be armed 5 ZONE Indicators Yellow Illuminated Zone bypassed Extinguished Zone clear Flashing Zone violated or tampered 3 Programmable Functions Functions include 5 4 4 Quick Away Arm Quick Stay Arm Arm with Entry Exit or Follower Zones Violated Stay Arm Stay Arm and Go Forced Arm Push to Arm Siren Sound on Arm Disarm single toot arm double toot disarm Panic Alarm Fire Alarm Chime Zones Buzz Zones Zone Tamper Arm with Key Switch or Remote Control Arming the Control Panel 4 1 How to Away Arm USER
21. m Chime Zones ee 21 12 2 How To Cancel Chime 65 22 13 Viewing Trouble 22 14 Remote Telephone 55 23 Tables Table 1 User Progamming 12 Table 2 Value Represented by each Zone Indicator 15 Table 3 Binary 15 Table 4 User Code Properties eee 16 Table 5 Trouble 23 Table 6 Remote Telephone 25 IDS816 USER MANUAL NO 700 283 01 C ISSUED FEB 2005 VER 2 00 1 Introduction to the IDS 816 The IDS816 is a versatile microprocessor based eight zone alarm panel It has two partitions and can be expanded to sixteen zones Most features are programmable and may be programmed using the IDS download software and a moden either directly through the keypad or via the telephone line There are eight programmable burglary zones a monitored siren output auxiliary power outputs and five programmable outputs which may be programmed to perform various trigger switching functions For correct operation the IDS816 must be used with the specified transformer battery combination and appropr
22. ng Un 9 Zone Number Bypassing a Zone Alarm Memory 0 Displays zones violated 03 02 Displays zones bypassed View Trouble Condtions 1 AC Mains fail 2 No Communication 3 Phone Line 4 Siren Tamper 5 Low Battery 6 Loss of clock timer 7 Engineer Reset 8 Box Tamper 10 Tamper on Peripheral 11 Comms failure to peripheral device 12 Loss of power to peripheral device 28 IDS816 USER MANUAL NO 700 283 01C ISSUED FEB 2005 VER 2 00
23. ogramming mode 13 Viewing Trouble Conditions Hold down the 7 key for two seconds until the keypad buzzer sounds The user is alerted to a trouble condition via a flashing power LED It is also possible to enable a trouble beep If the trouble beep has been enabled the keypad buzzer will sound to alert the user that a trouble condition has occured Press the key to silence the buzzer Hold down the 7 key for two seconds The ARMED AWAY and READY indicators will start flashing to show that the keypad is in the TROUBLE VIEW MODE Refer to the table 5 below to find the significance of each illuminated zone LED The system will automatically exit the TROUBLE VIEWING MODE after one minute To exit this mode press IDS816 USER MANUAL NO 700 283 01 C ISSUED FEB 2005 VER 2 00 23 Note Certain trouble conditions will only clear once the trouble condition has restored To simply cancel the beeping without viewing the trouble conditions press key Table 5 Trouble Conditions Indicator Trouble Condition 1 AC Mains Failure Failure to communicate successfully to monitoring company Phone line trouble Siren tamper Low battery Loss of Clock Timer Engineer Reset Box tamper O O NO a R oN Na o Tamper on peripheral device Communication loss to peripheral device M Loss of power to peripheral devices
24. ound A PANIC ALARM will be transmitted to the monitoring company s To silence the siren enter a valid USER CODE Press the P key only in an emergency situation that requires response by emergency personnel 7 3 Medical Alarms M Hold down the M key for two seconds until the keypad buzzer sounds If the M key is pressed until the keypad beeps approximately 2 seconds a MEDICAL ALARM condition will be activated The keypad buzzer will beep 5 times A medical reporting code will be reported to the monitoring company 4 4 74 Duress Alarms F DURESS CODE This is a special user code which should only be used in the unique situation where an intruder forces one to disarm the system iunder duressi s When a DURESS CODE is entered the control panel disarms normally A Duress Alarm Code if programmed will be reported to the monitoring company It is advisable to choose a Duress code that can be easily remembered by all family or staff members 8 Alarm Memory The Alarm Memory displays any zones which were violated or bypassed during the last arm cycle A flashing ARMED indicator notifies the user of an alarm memory condition To view the alarm memory disarm the panel and continue as indicated as follows IDS816 USER MANUAL NO 700 283 01 C ISSUED FEB 2005 VER 2 00 11 To Display Alarm Memory 0 Hold down the 0 key for two seconds un
25. p If steps 2 5 are performed correctly the READY indicator will flash If an invalid code was entered the keypad buzzer will give an error beep 3 short beeps If the error beep occurs press the key this clears all previous entries and repeat steps 2 5 Select a menu option from Table 1 above For example add a new user code enter User Program Mode by completing steps 2 6 as listed above To access menu 0 enter a value of 0 See table 1 followed by Enter a NEW USER CODE followed by the x key Once the user code is programmed enter the IDS816 USER MANUAL NO 700 283 01 C ISSUED FEB 2005 VER 2 00 13 next code followed by x To exit the program mode press the key For a full list of programmable user code options refer to Table 1 Programing of these options is explained below 9 3 Explanation of Programmable Options 9 3 1 Option 0 Add a New User Code Hold Master Code 0 New Code 1 Enter the User Program Mode as per steps 1 5 of 9 2 2 Press the 0 key followed by the key to select the programmable option 0 The Ready and Armed indicators will flash simultaneously 3 Enter the NEW USER CODE followed by the key 4 Further codes may be added by repeating step 3 above 5 After entering the last code press the key to exit the user program mode 9 3 2 Option 1 Edit a User Name LCD Keypads only 14 Hold Master Code
26. rties Press Master Code 4 User Code 2 or 3 or 4 1 2 Enter the User Program Mode as per steps 1 5 of Section 9 2 Press the 4 key followed by the x key to select programmable option 4 The READY and ARMED indicators will flash simultaneously Enter the USER CODE followed by the x key The READY indicator will flash and the AWAY indicator will be illuminated 16 IDS816 USER MANUAL NO 700 283 01C ISSUED FEB 2005 VER 2 00 For example 7 8 The properties assigned to the USER CODE are displayed by the Zone indicators An illuminated LED indicates that a property is active for the USER CODE Refer to Table 4 for a list of USER CODE properties To select a user code property press the key which corresponds to that property followed by the x key The appropriate zone LED will illuminate To deselect a property press the corresponding key followed by the x key and the LED will be extinguished To enable a User Code to function as a duress code press the 2 key followed by the key The zone 2 LED will illuminate to confirm the selection Repeat step 5 until the desired properties have been programmed Press the key to exit the User Program Mode Table 4 User Code Properties Zone LED Property 2 Duress Code 3 Arm to Disarm Code Maids Code 4 Global Arm Disarm Code Explanation of User Code Propertie
27. s 9 3 5 1 Duress Code This is a special 4 default or 6 digit user code check your code length with your installer which should only be used in the unigue situation where an intruder forces one to disarm the system iunder duressi s When the DURESS CODE is entered the control panel disarms normally however a DURESS REPORTING CODE is trans mitted to the monitoring company to inform them that you have been forced to disarm the control panel by an intruder Itis advisable to choose a code that can be easily remembered by all family or staff members 9 3 5 2 Maids Code The maids code may be used to limit access to the premises The IDS816 USER MANUAL 700 283 01 C ISSUED FEB 2005 VER 2 00 17 maids code will only disarm the system if the same code was used for arming If armed with a code other than a maids code the system will view an attempt to disarm with the maids code as an invalid entry Any valid user code will disarm the system if it has been armed with the maids code 9 3 5 3 Global Arm Disarm Code The code when entered will either arm or disarm the partitions assigned to that user depending on their status If both partitions are disarmed entering a global code will arm both partitions If both partitions are armed entering a global code will disarm them In the case where one partition is armed and the other disarmed entering a global code at the keypad of the armed partition will disarm th
28. sanai vani sn n nakonan v v sk no znie 12 Adding Deleting and Editing User Codes 12 How to Enter the User Program Mode 13 Option 0 Add a New User 13 Option 1 Edit a User Name ee 14 Option 2 Edit a Selected User 14 2 IDS816 USER MANUAL NO 700 283 01C ISSUED FEB 2005 VER 2 00 9 3 4 Option 3 View a User Clode Slot Number 14 9 3 5 Option 4 User Code 15 9 3 5 1 Duress Code Explanation of User Code Properties 16 9 3 5 2 Maids Code ze eee nee 16 9 3 5 3 Global Arm 8 17 9 3 6 Option 5 Assign User Code to Partition 17 9 3 7 Option 9 Deleted User Code Code known 17 9 3 8 Option 10 Delete a User Code Slot known 18 10 Stay ZONES di vak Kandia n radia 18 10 1 How To Select a Stay Profile 19 10 2 How To Program Stay 65 19 10 3 How To Cancel Stay ZONES eee 19 11 BUZZ ZONES 20 11 1 How Program 65 20 11 2 How Cancel Buzz 65 21 12 Chime ZONES n ln to ihudnisn ikon seete 21 12 1 How To Progra
29. til the keypad buzzer sounds Hold down 0 until the keypad buzzer sounds The READY and POWER indicator will extinguish and the keypad buzzer will sound briefly 3 Illuminated zone indicators show which zones were violated during the last armed period Press 2 to display zones which were bypassed Press 3 to display which zones were tampered Press 1 to return to violated zones The alarm memory is erased at the beginning of each arm cycle M NOOR 9 User Codes The IDS 816 Alarm Panel has 32 programmable user codes By default code 1 is the Master User Code This alarm panel may have 1 or 2 partitions A partition is an independant group of zones that can be armed and disarmed without affecting other zones or users Note User codes may be 4 default or 6 digits long As this is a programmable feature please check this with your installer 9 1 Adding Deleting and Editing User codes Hold x MASTER USER CODE PROGRAMMABLE OPTION The IDS 816 utilizes a user friendly driven programmable interface which allows the user to add modify or delete user codes See Table 1 for a summary of programmable options The programmable interface is accessed by entering USER PROGRAMMING MODE Once in user programming mode it is a simple matter to add view edit or delete user codes When a new user code is added it is stored in the first available user slot 12 IDS816 USER MANUAL NO 7
30. tors must be bypassed when istaying at homei Stay zones need only be programmed once Each time the system is armed in the Stay Mode the preselected stay zones will be bypassed automatically The panel allows for two unique STAY PROFILES to be stored A STAY PROFILE stores a pre selected combination of STAY and BUZZ zones to suit a specific STAY ARM requirement If a partition is stay armed using Profile one it is possible to toggle the panel arm status directly to stay arm profile 2 by holding the 5 key for two seconds STAY and BUZZ zones can be programmed for each profile once the profile has been selected See section 10 and 11 10 1 How to Select a Stay Profile MODE 2 PROFILE NUMBER Press the key to clear any previous entries Hold MODE down for one second until the keypad beeps Press the 2 key followed by the x key Press 1 or 2 for the required profile Press to enter The buzzer will give a long beep Program STAY and BUZZ zones for the profile or ARM the profile See sections 10 and 11 DRN 10 2 How to Program Stay Zones 3 ZONE NUMBER Select ihe reguired stay profile See 10 1 2 Holddown the 3 key until the keypad buzzer sounds The AWAY indicator will flash to show that the panel is in the Stay Zone programming mode 3 Press the NUMBER corresponding to the zone you wish to be a STAY zone followed by the x key