1. EPS SERIES ELECTRONIC BALANCE USER S MANUAL 1 Description EPS series portable electronic scales are precision weighing instruments The portable advanced scale consists of a housing constructed of a material which is impact resistant a one piece solid state precision electronic PC board with a 5 digit LCD displayer which is 0 5 inches in height and a strain gauge load cell inside All portable balances are initially factory set to measure in grams and can be set to other units of measure as desired Each balance operates through a series of menus that enable precise calibration and the selection of various parameters that enhances operation A built in lock switch prevents calibration settings from being changed Power is supplied through an AC adapter or batteries 2 Setup menus Press and hold the MODE key for 3 seconds to access the setup menu continue to press the UNIT key to make selection among Unit unit selection A OFF automatic power off CAL calibration and END exit menu In this process you can press TARE key to access a submenu and exit the menu by another touch on TARE when END appears 2 1 Unit selection The unit selection submenu permits you to specify which weighing units and operating modes will be enabled for use during operation The adjacent table lists the units and modes available on the EPS series balances Proceed as Display Weighing unts Follow
2. and wait for a few seconds until the displayer stops flashing and shows the value of the calibrating mass that indicates calibration finishes and normal weighing can be done 2 3 2 Linearity calibration When the scale displays LINE press TARE key to see the scale flashes Wait for a few seconds the scale flashes half of the value of the full load specified Put onto the pan the calibrated mass corresponding to the value displayed The scale then flashes the value of the required calibrated mass for full load a few seconds later Put on the corresponding weight to wait till the scale stops flashing and displays the value of the calibrated mass loaded thus the calibration finishes normal weighing can be done Remark Scales are factory calibrated When linearity calibration is necessary or a load cell is replaced please use an accurately calibrated mass to calibrate the scale 3 Backlight Press MODE key to switch on or off the backlight 4 RS232C communication 4 1 Wiring method Connect the scale with PC as below 1 Empty 1 2 RXD j lt 2 RXD 3 TXD 3 TXD 4 4 p 5 G __ 5 G 6 6 7 7 s 8 9 Empty 9 4 2 Baud rate 9600 4 3 Data format output 6 XXX XX Unit lt CR gt lt LF gt All segments above belong to ASC II in which the unit can be that set for the scale 4 4 Demonstrating software of communication a The super end under Win9x NT 2000 XP b The debugging ass
3. ate weights Use properly calibrated being used in calibrated weights accurately calibration 8 Packing list 1 An electronic scale 2 An AC adapter 3 User s manual 9 Limited warranty There is a year s free guarantee with the scale dating from the time when it leaves the factory including free check maintenance and parts replacement But the followings are excluded from our guarantee Faults due to mal use of the scale erosion by radioactive or corrosive materials that result in foreign materials permeating the scale Damage due to improper check and maintenance by any unauthorized person Sensor load cell destroyed due to man made factors
4. istant on http www gjwtech com c Self arranging communication software 5 Care and maintenance To keep the scale operating properly the housing and weighing pan should be kept clean and free from foreign material If necessary a cloth dampened with a mild detergent may be used Keep the calibration mass in a safe dry place Always unplug the AC adapter when not in use and remove the batteries from the housing for long term storage 6 Error codes The following list describes the various errors that may appear on the display and the suggested remedies Display description ERR 0 With the weighing pan on this indicates the pan is too light make it heavier properly If this error still occurs the sensor load cell or the circuit board may be destroyed The scale must be sent to the manufacturer to be serviced 0 LOAD This indicates that the weight loaded on the scale exceeds the capacity specified If this error occurs when the loaded weight is in the range of the capacity of the scale please re calibrate the scale with an accurate calibration mass 7 Troubleshooting No display Power adapter not Check power supply ready Replace the power Dead battery source or batteries Low battery Weak battery Recharge the battery indicator ial Incorrect Scale is not tared With no load on the weight before use pan press TARE reading Scale not properly before weighing calibrated Re calibrate Can not be Inaccur
5. s 1 Indicator and Modes a Press MODE key for 3 seconds to access the setup A grants menu the display will show UNIT oz ounces b Press TARE key the display will show the grams troy ounces unit indicator g along with the current status pennyweight ON OFF pounds x M taels Press UNIT to change the status carat parts counting a o Press TARE to accept the displayed status when re leased the display will show the next unit indicator along with the current status o Set each unit or mode ON or OFF as in steps c and d Th After finishing units setting press unit key continuously to find the setup menus displayed in circle Press TARE when END appears to exit setup menu 2 1 1 Taels selection If taels are enabled you will be required to choose one of three different taels Hong Kong Singapore or Taiwan correspondingly as below TAEL 1 Hong Kong tael TAEL 2 Singapore tael and TAEL 3 Taiwan tael 2 2 Auto off Auto off permits the selection of either OFF 60 seconds 120seconds or 180 seconds When this function is selected the balance will turn off if it is idle for the selected period of time 60 120 or 180 seconds This feature is especially useful when the balance is operated from internal batteries 2 2 1 View change or disable the auto off feature Press MODE key for 3 seconds to access the setup menu Press UNIT key contin
6. uously to find the A OFF setup submenu Press TARE key to check the current auto off status Press UNIT to change the status Press TARE key to confirm the setting Releasing the TARE key A OFF will be displayed again Press UNIT key continuously to find that END appears then another touch on TARE to exit mo Bop setup 2 3 Calibration When precise weighing is necessary please calibrate the scales as follows a With no load on the pan press and hold the MODE key for 3 seconds the scale will display UNIT indicating accessing the setup menu b Press UNIT key twice to access the CAL ON submenu c Press TARE key to confirm The scale will display SCALE or LINE that can be shifted by pressing the UNIT key SCALE means sensitivity calibration and LINE indicates linearity calibration of the scale Press TARE to confirm the desired calibration option 2 3 1 Sensitivity Calibration When the display shows SCALE press TARE key to find the currently required calibrated mass displayed on the screen Press UNIT key once again shift between the two optional calibrated masses Pressing TARE key to confirm one of the two desired for calibration zero first flashes on the displayer then automatically shifts to flashing value of the calibrated mass Put the corresponding calibrated weight on the pan