        User Manual for Version 1.0 of the Firmware
         Contents
1.  4  April 2012 mspeed    a    Parameter 15  0 255 Pulse Timer Scale   Factory Default   255   0 255   Pulse timer clock that divides wind speed scale  This value is also the maximum value of the display   255     Full scale   127   1 2 scale    63   1 4 scale  31  1 8 scale  16  1 16 scale  8   1 382 scale  4   1 64 scale  2  1 128 scale  1  1 256 scale  0   Display  0    Parameter 16  0 255 Pulses Per Period Timer   Factory Default   68   0 255   This Parameter sets the pulse counting time period   Factory Preset Values are       68 MPH  108 KPH  56 Knots    100 Feet Second  30 Meters per second    Parameter 17  0 31 Oscillator Fine Tune   Factory default   16   0 32   This parameter adjusts the frequency of the internal oscillator of the microcontroller  Increasing value will  decrease wind speed measurements  This parameter also affects the Real Time Clock  an increase in oscillator  frequency will decrease the time that the latch timers are on     0    12   16  0   31    12     Wy  Version 4  April 2012 MSPCCL        
2.  On   Ground  Relay 1 on    Off   Hi Z  Relay 1 unpredictable        There should always be at least a 1K ohm resistor connected between any external circuitry and the Alarm 1 and  Alarm 2 logic pins  Failure to observe this rule may result in damage to the microprocessor chip and voids any  warranty     WZ    Version 4  April 2012 MSPECL        a    Parameter 9  0 255 Alarm 2 On Threshold   Factory Default   0   0   Alarm 1 Off   1 255   Alarm 1 turns on when wind speed is equal to this value     Parameter 10  0 255 Alarm 2 Off Threshold   Factory Default   0   0   Alarm 1 stays on until manually reset    1 255   Alarm 1 turns off when wind speed is less than this value     This value may not be greater than Alarm 2 On Threshold  the program will not allow it and will adjust during data save  if needed     Parameter 11  0 255 Alarm 2 Latch Timer  Factory Default   0   0   Latch disabled   1 255   Minutes that Alarm 1 Latch will stay on     The Latch Timer is not entirely precise      A setting of 1 will result in a latch time between 0 and 1 minutes   A setting of 2 Will result in a latch time between 1 and 2 minutes   A setting of 3 Will result in a latch time between 2 and 3 minutes   And so on       Parameter 12  0   6 Alarm 2 Output Logic    Available at    AL2    pin on the circuit board  Factory Default   0   0   On   Ground  Relay 2 on    Off    5V  Relay 2 off    1   On   Ground  Relay 2 off    Off   Weak pull up  5V  Relay 2 off    2   On    5V  Relay 2 on    Off   
3. Ground  Relay 2 on    3   On   Weak pull up  5V  Relay 2 off    Off   Ground  Relay 2 on    4   On   Hi Z    Relay 2 unpredictable    Off    5V  Relay 2 off    5   On   Hi Z    Relay 2 unpredictable    Off    5V  Relay 2 on    6   On   Ground  Relay 2 on    Off   Hi Z    Relay 2 unpredictable        There should be a 1K ohm or greater resistor connected between any external circuitry and the Alarm 1 and Alarm 2  logic pins  If current through these pins exceeds 50 milliamps the microprocessor can be damaged  This failure is not  covered by warranty        These modes are used for logic level interface  the relay coil jumpers should be removed     Parameter 13  0 255 Pulse Timer Clock  Low Byte    Factory Default   213   0 255   Pulse timer clock that determines wind speed scale    Factory Preset Values are      213 MPH  Pulse Timer Clock High Byte   255   Pulse Timer Scale   255    173 KPH  Pulse Timer Clock High Byte   255   Pulse Timer Scale   255    220 Knots  Pulse Timer Clock High Byte   255   Pulse Timer Scale   255    185 Feet Second  Pulse Timer Clock High Byte   255   Pulse Timer Scale   255   220 Meters second  Pulse Timer Clock High Byte   255   Pulse Timer Scale   127     Parameter 14  0 255 Pulse Timer Clock  High Byte   Factory Default   255  0 255   Pulse timer clock that determines wind speed scale     Values below about 250 have very long timing periods and usually result excessive rollovers of the wind speed display  making it look confused     WZ    Version
4. Heliotrack Programmable Wind Alarm Switch V1 0  Developed in partnership with Inspeed com  LLC    IMPORTANT DISCLAIMER    Niether Heliotrack _LLC nor Inspeed assume any responsibility for damages caused  by the use or misuse of our products  either directly or indirectly  Extreme caution  should be exercised when using this device  See    http   www inspeed com Terms And Conditions asp for additional information on  Terms of Use     Features    e 9 36 VAC or VDC power supply input   e Wind speed up   e Two alarms with relay or logic outputs   e Display in MPH  KPH  Knots  Ft sec  M sec  or user calibrated  e User settable wind speed averaging up to 60 seconds   e Each alarm has independent ON and OFF wind speed thresholds  e Each alarm has a latch timer adjustable from 0     255 minutes  e Each alarm can be set to latch until manually reset   e 3 digit display indicates wind speed up to 255 units   e Screw terminals for easy connections    Possible Applications    e Parking solar panel trackers in high wind   e Retracting RV awnings for high wind protection   e High wind alarm for crane operators   e Turn water pumps on or off for outdoor fountains   e Any application that requires some action based on wind speed                                  Specifications    Specification Value   Input Power supply 9     36 Volts AC or DC   Idle current drain  020 Amps   Logic power supply 5 0 Volts DC   5 amps    Relay contacts 36V   10 AMPS   Operating Temperature  40C to  150C  PCB an
5. antaneous wind speed    3   Alarm 1 triggered by instantaneous wind speed  Alarm 2 triggered by instantaneous wind speed     Parameter 5  0 255 Alarm 1 On Threshold   Factory Default   0   0   Alarm 1 Off   1 255   Alarm 1 turns on when wind speed is equal to this selected value     Parameter 6  0 255 Alarm 1 Off Threshold   Factory Default   0   0   Alarm 1 Latches until reset   1 255   Alarm 1 turns off when wind speed is less than this selected value     This value may not be greater than Alarm 1 On Threshold  the program will not allow it and will adjust during data save  if needed     Parameter 7  0 255 Alarm 1 Latch Timer  Factory Default   0   0   Latch disabled   1 255   Minutes that Alarm 1 Latch will stay on     The Latch Timer is not entirely precise      A setting of 1 will result in a latch time between 0 and 1 minutes   A setting of 2 Will result in a latch time between 1 and 2 minutes   A setting of 3 Will result in a latch time between 2 and 3 minutes   And so on       Parameter 8  0 6 Alarm 1 Output Logic    Available at    AL1    pin on the circuit board  Factory Default   0   0   On   Ground  Relay 1 on    Off    5V  Relay 1 off    1   On   Ground  Relay 1 off    Off   Weak pull up  5V  Relay 1 off    2   On    5V  Relay 1 on    Off   Ground  Relay 1 on    3   On   Weak pull up  5V  Relay 1 off    Off   Ground  Relay 1 on    4   On   Hi Z  Relay 1 unpredictable    Off    5V  Relay 1 off    5   On   Hi Z  Relay 1 unpredictable    Off    5V  Relay 1 on    6  
6. d components        Wind Switch Alarm circuit description   The wind alarm switch will turn on or off electrical load up to 10 amps at 48VDC based on wind speed     Display   The display is 3 digits capable of displaying wind speed up to 255 units  MPH  KPH  Knots  Meters sec  Feet sec  or  user calibration   The display also shows programming parameters and parameter values while in programming mode     Installation instructions    1  Mount controller in desired location    2  Mount anemometer sensor in desired location    3  Connect power wires to the controller  making sure they are not energized    4  Connect the anemometer sensor wires  If you have a reed sensor use the SENSOR and GND terminals  If you have  a hall sensor you will likely use the  5 terminal as well    WZ    Version 4  April 2012 MSPECU        he       aaa    5  Turn on power supply 9     36 volts AC or DC    6  Program controller with desired settings    7  Replace the cover on the control box when you are satisfied that everything is working properly  Do not over tighten  the screws on the lid  this can cause the lid to warp resulting in an improper seal  For permanent outdoor installations it  is a good idea to put a bead of caulking around the cable penetrations if watertight grommets are not being used     Relays   Relays are rated up to 48 volts   10 amps  If you wish to use logic level outputs only then the relay enable jumpers   J1  amp  J2  should be removed  These jumpers interrupt current to th
7. e relay coils     POWERUP   When the controller turns on it will display the software version for a couple of seconds    1 0    and then start displaying  the current wind speed     Run Mode  This is the default mode when power is connected or after resetting    Button 1  Enter Programming mode   Button 2  Turn on Alarm 1 when pressed  display Alarm 1 on threshold  Alarm 1 Latch is reset when button is  released    Button 3  Turn on Alarm 2 when pressed  display Alarm 2 on threshold  Alarm 2 Latch is reset when button is  released    Button 4  Step through display modes  1 Instantaneous wind speed   2 Average wind speed   3 Maximum wind speed    4 Off    Pressing Buttons 1  2  or 3 will also clear the maximum wind speed    Reset Button  Used with Buttons 1  amp  2 for restoring controller to the factory presets  Pressing the reset button may  cause the relays to chatter  remove the relay jumpers before resetting if sensitive or high power loads connected to the  relay outputs  Holding down Buttons 1 and 2 while powering up or pressing the reset button will restore the controller to  the factory presets     Programming Mode  Press Button 1 to enter programming mode    Button 1  Exit Programming mode and save changes    Button 2  Move to next Parameter  Parameters will increase to 255 and then roll over to 0   Button 3  Add 1 to current parameter    Button 4  Add 10 to current parameter     Parameter 1  0 1 Measuring Method   Factory Default   0   0   Pulse Timer Mode  Wind spe
8. ed is determined by measuring the time between each reed sensor pulse   1   Pulses Per Period Mode  Wind speed is determined by counting the number of pulses per unit of time     When the Pulses Per Period mode is selected the wind speed refresh rate on the display will be between 2 and 5  seconds depending on the Wind Speed Units parameter value    Approximate wind speed display refresh rates for Pulses Per Period mode are    0   MPH   2 5 seconds   1   KPH   5 seconds   2   Knots   2 2 seconds   3   Feet Seconds   5 seconds   4   Meters Seconds   1 5 seconds   5   User calibrated   Variable    Parameter 2  0 5 Wind Speed Units  Factory Default   0   O MPH  1 255    1 KPH  1 255    2   Knots  1 255    3   Feet Second  1 255     Wy  Version 4  April 2012 mspeed    hea    4   Meters per second  1 127   5   User calibrated    Parameter 3  0 60 Wind Speed Averaging Time   Factory Default   0   0   No averaging  instantaneous wind speed is displayed    1 60   Number of seconds over which the wind speed is averaged     In Pulses Per Period Mode there is a minimum averaging time of approximately 2     4 seconds depending on the    Wind  Speed Units    parameter setting     Parameter 4  0 3 Alarm Trigger Method   Factory Default   0   0   Alarm 1 triggered by average wind speed  Alarm 2 triggered by average wind speed    1   Alarm 1 triggered by instantaneous wind speed  Alarm 2 triggered by average wind speed    2   Alarm 1 triggered by average wind speed  Alarm 2 triggered by inst
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Módulo de Web Conference  Prüfliste vor der Installation  Selection Guide - Anglia Components  1 Aplicación Características Generales Medidor de Espesores  ICC ICACSTCTFD  2011 Dodge Nitro User`s Guide  Word Pro - SO 2020 inox INDICE  INSTRUCTIONS MANUAL  LaCie Silverlining Pro ® U s e r `s Guide  取扱説明書 - 山田照明    Copyright © All rights reserved. 