Home
User Manual Central Vacuum System NADAIR-700-AL-32
Contents
1. User Manual Central Vacuum System Model Number NADAIR 700 AL 32 GR C 174405 US www NadairVac com Index t IMPOrlan salety INSWUCNOT SB ee ea 3 2 General guidelines and references 02400220020000000 0000 nenn nnn nenne nnn nano nano nnnennne nenn nennen 4 Grounding requirements General guidelines to be respected at all times AMOS E ea ee 5 AR EE Ee p E E E E E E E E E AE EE 5 Power Unit 9 LOW YOIGO V Oe E ae E E E E E 5 Installation instructions OVS EMODE ra ON MS TUC ION en ee ee 6 R SU E E NG ee ee een 6 Filtration system Motor 8 FrOUDIGSNOOUN Gesandter ee een dere T General Ja COW VOLAGE SY EIN ee E O AE A E E ee LED Interpretation chart 10 SC HOlOS ee ee ne E ee 11 Nadar S WAHaNV een reed 9 Page 2 1 Important instructions related to safety CAREFULLY READ ALL OF THESE INSTRUCTIONS PRIOR TO USE THIS CENTRAL VACUUM SYSTEM When using an electrical appliance it is necessary to obey certain basic precautions WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY Unplug the power cord from electrical outlet before making any power unit maintenance Do not install outdoors protect against weathering and do not use on wet surfaces This appliance must not be used as if it is a toy It is therefore necessary to be very prudent when the system is used by children or when in use in the proximity of a child or infant This system must be used in conformi
2. 7 SYSTEM MAINTENANCE FILTRATION SYSTEM IMPORTANT In order to maintain optimal air oe quality in your home the power unit comes supplied with a high efficiency HYBRID filtering system A permanent polypropylene washable and reusable filter together with an optionnal 22 5Ldisposable filter bag The permanent filter must be in place at all times the filter securing strap must be tightened just so as to insure no fly by of debris into the motor housing This Nadair hybrid power unit may be used with or without a 22 5L disposable bag 3 bags pak FD 22 5L 3NAD The disposable bag installs as shown here 1 Remove the debris canister 2 Remove the dirt filled bag 3 Install the new bag by twisting it 4 Verify and clean if necessary the permanent filter 5 Replace the debris canister and secure the latches NOTE When replacing the disposable bag make sure that the rubber diaphragm is correctly installed onto the intake PVC pipe Make sure that the bag is not cut or damaged Make sure that the canister is secured in place prior to restarting the power unit It is recommended to replace the disposable bag or to empty the debris canister as well as to clean the permanent filter 3 or 4 times per year If the system is used more frequently than normal repeat the above procedure more often IMPORTANT NEVER USE this system to pick up liquids mud or combustible materials To vacuum baking flower talcum powder cem
3. 5 7 Verify that the permanent filter and the optionnal disposable bag are in place and that the debris canister is properly installed with the latches secured 8 Plug in the unit s power cord into the electrical outlet 9 Install the muffler supplied to the exhaust pipe circuit by using the provided flexible pipe and collars DO NOT GLUE you may elect to vent to the outside with the help of a vent cap not supplied 6 SYSTEM OPERATING INSTRUCTIONS Your new system is now ready to be used Here are a few simple guidelines to follow when you are using your Nadair Central Vacuum System Insert the wall end of the hose into one of the vacuum valves installed throughout your home and you are ready to start press the switch on the hose handle NOTE In regards to the low voltage system All vacuum inlet valves are fitted with two 2 springloaded metal pins see inside the valve opening When the two 2 metal parts of the hose wall end are in contact with the two 2 pins inside the valve the system is energized You may now turn it on or off from the hose handle switch if this option was selected The low voltage cable is connected in parrallel from every valve it runs all along the pipe network and brings the power to the the remote switch so to remotely start or stop the power unit in all safety A standard flexible hose not fitted with an interruptor will start the power unit as soon as it is inserted in the valve opening
4. a current carrying hose and electrically motorised brush Only connect a current carrying hose to this wall valve Do not install a current carrying valve outdoors Do not use a damaged hose bring in the hose for repair at an authorized service center Page 4 3 MODELS Disposable Filtration Bag NOTE APPLICABLE TO ALL POWER UNITS In order to avoid overheating we recommend that 12 30cm of clearance be kept all around the power unit 9 LOW VOLTAGE SYSTEM INSTALLATION Prior to connect the low voltage wires make certain that the power cord is unplugged from the electrical outlet 1 First strip the conductors of the low voltage wire for about 3 8 10mm 2 Insert the conductors of the low voltage wire in the terminals live in the black terminal and neutral in the red terminal while simultaneously pushing on their respective button Give a light pull to the wire to make certain that it is well secured in the terminal 3 To remove the conductors out of the terminals lightly push the button as you are simultaneously gently pulling the wires out 4 INSTALLATION 10 25cm minimum 16 40cm E 3 4 2cm Mount a Mounting board Meunene Relat The power unit must be installed in a well ventilated area away from weathering it must be easilly accessible and away frrom any heat source The power unit must be installed near an adequate electrical outlet 1 Determine the power un
5. i e goggles gloves etc Use the right tools amp in good working order Hammer Phillips head screwdriver cruciform x Measuring tape Level Drill with wood or concrete bit of 3 8 10mm NADAR Wire stripper Page 8 Limited lifetime WARRANTY The Nadair warranty on the central vacuum system amp power unit is only valid for the original owner and is non transferable The use of electrical power other than prescribed on the unit and or any repair s made by other than authorized service person will render this warranty null amp void The warranty will also be null amp void if the system and or its accessories have been used on wet surfaces This warranty is for residential application only this warranty does not cover commercial or industrial usage of the product Proof of purchase is mandatory The Central Vacuum Power Unit body Lifetime warranty Nadair will at no cost repair or replace any defective parts of the central vacuum power unit s body housing amp dust bin as long as you own it if used in normal conditions and properly maintained as stated in the power unit instruction manual The Central Vacuum Power Unit s motor amp module five 5 years Nadair will at no cost repair or replace any defective motor or electronic module of the central vacuum power unit for the first five 5 complete years following the purchase date if used in normal conditions and properly maintained
6. as stated in the power unit instruction manual Available additional one 1 year warranty To the standard five 5 years warranty one 1 more year can be added for any part s that may be found defective during this additional period to be eligible to the additional one 1 year of warranty The power unit warranty registration must be done online within 90 days of the original purchase date at www NadairVac com warranty registration Cleaning tools carpet brushes and flexible hoses two 2 years The cleaning tools the carpet brushes and the flexible hoses used adequately and in normal conditions are warranted for a period of two 2 years following the original date of purchase against manufacturing defects The warranty does not cover the normal wear of bristles turbines lamps belts carbon brushes and roller bearings from the power brush War En 12 Oct 01 Page 9 For future references take note of the following informations Serial number Date of purchase Purchased at Please keep a copy of your invoice together with this manual Document U Manu EN 120 Nadair 700 AL 32 Rev 2012 Nov 29
7. ebris intake line If you have plenty of power there it is a sign that the clog is between the last valve and the power unit If the power unit still does not work after the above diagnostic bring the unit to the nearest authorized service center Page 7 9 LOW VOLTAGE SYSTEM TECHNOLOGY LED status interpretation guide This Nadair Central Vacuum Power Unit is provided with an LED status indicator to keep you informed on the different states and functions during its operation Rea ding the following table will allow you to identify the status of your appliance by the different behaviors of the LED Legend OFF The power cord is unplugged No power The power cord has just been plugged in or the power has Fr been restored The LED will flash rapidly for a few seconds and will then become solid again GREEN The power unit is operational Z o Z oo Stop the power unit replace the bag and clean the permanent filter if required after 15 hours of usage reboot the unit by pressing the small button for 5 seconds The LED will return to a ee BE the motor may get damaged a a er immediately at an authorized service center Slow blinking LED Fast blinking LED Solid No blinking 10 SAFETY NOTES Make certain that the work area is safe and clear prior to installing your new Nadair Central Vacuum Power Unit Wear the necessary safety clothing amp equipment prior to start any work
8. ent or gypsum dust will have for effect to obstruct and eventually clog the filter media you have to clean the filter several time during and after such pick ups Otherwise the power unit performances will be affected the motor will overheat and may be damaged MOTOR This Nadair power unit is equipped with a soft start controler and a delayed stop Awarning is automatically programmed after 500 hours of usage The inspection and the maintenance of this appliance must be done in an authorized service center A Mini breaker shall cutt off power to protect the motor in the event of a power surge which may cause the motor to overheat The low voltage technology system communicates the power unit status through a muticolor LED on the side of the unit Please consult the interpretation chart in section 8 Page 6 8 TROUBLESHOOTING GENERAL The following may cause failure of the power unit Inadequate electrical power Voltage or Amperage verify that the electrical power supplied complies with the power unit s requirement or Abnormal performances of the electronic control module or the motor Before calling a service technician in case of a malfunction please review the following situations by running the following simple diagnostics THE POWER UNIT DOES NOT OPERATE Short circuit the low voltage connections on the side of the power unit If the power unit starts the problem is somewhere else in the valve network wiring or
9. er unit grounding wire can result in the risk of electric shock If you are in doubt of a proper grounding contact a professionnal electrician Do not modify the power cord supplied with this power unit If this power cord connector does not fit your electrical outlet have the proper electrical outlet installed by a professionnal electrician This power unit is designed to be used on a nominal electrical circuit of 15 A 110 120 VAC in 60 Hz The power cord is fitted with a grounding pin Make certain that the power cord is plugged into an electrical outlet having the same specifications This appliance should be used without an adaptor This power unit should be installed on its own independant circuit and breaker General guidelines to be respected at all time IMPORTANT The manufacturer shall not be held responsible for damages cause by the innapropriate use of this system The warranty does not cover the damages caused by an innapropriate use of this system nor the problems resulting from an installation which does not meet the specifications nor any structural or functional alterations made to the power unit An innapropriate not recommended installation of the system or the power unit made without respecting the directives of this document will equally be considered as misuse All conditions and restrictions are set forth in the limited warranty and in the user manual To optimize the performances and the life of your Nadair power uni
10. ical socket For more information on this subject please see Grounding specifications in section 2 The exhaust of the power unit must not give right against a wall a ceiling or be inside a closed space inside a building or structure It is recommended that the exhaust be vented outdoors Do not pick up hot ashes red ambers smoking hot material incandescent material cigarette butts matches etc Do not put anything on top of the power unit or near it because this could cause the unit to overheat DO NOT use the power unit if the pipe network is clogged this will cause the unit to overheat KEEP THESE INSTRUCTIONS IN A SAFE PLACE THIS POWER UNIT IS FOR DOMESTIC USE ONLY i Page 3 2 GENERAL DIRECTIVES AND REFERENCES ELECTRICAL GROUNDING SPECIFICATIONS The system s power unit must absolutely be grounded In the event of a malfunction or a power unit failure the grounding provides the path of least resistance to any electrical current minimizing the risk of electric shock The power unit s power cord has a length of 65 1 65m and is fitted with a grounding wire and grounding pin The power unit s power cord must always be directly plugged into a suitable electrical outlet which is itself properly installed and properly grounded in comformity with the current local electrical standards Do not use extension cord s to connect the power unit to the electrical outlet WARNING Improper connection of the pow
11. it location on the wall we recommend that the power unit be hung at approximately 60 1 5m off the ground so that the debris container is easilly accessible Allow at least 12 30cm of clearance all aorund the power unit If at all possible you may mount the unit directly onto a concrete wall as to minimize the transmis sion of vibrations into the building 2 Installation on a gypsum wall Gyprock Prepare the wall by installing a plywood mounting board not provided of 16 40cm high and 0 75 2cm thick wide enough to be screwed to at least 2 studs Drill three 3 3 8 10mm holes with a wood drill bit Insert the supplied rubber inserts Fasten the steel mounting bracket with the supplied screws 3 Installation on a concrete wall Drill three 3 3 8 10mm holes with a concrete drill bit Insert the supplied rubber inserts Fasten the steel mounting bracket with the supplied screws NOTE You may also elect to install a plywood mounting board on the concrete wall IMPORTANT Always use the supplied screws and rubber inserts or the appropriate ones for the material you are working with Wood Steel Brick etc 4 Mount the power unit onto the installed wall mounting bracket 5 Connect the top air and debris intake pipe to the PVC pipe network by using the provided flexible pipe and collars DO NOT GLUE 6 Connect the low voltage wire to the terminals on the side of the power unit as shown in section
12. on the current carrying hose Verify that all low voltage connections are adequate at every valve location Open every valve one at a time and make contact between the two 2 small pins with a metal object If all the valves work properly take a look at the low voltage circuit or switch on the hose If the power unit still does not work after the above diagnostic bring the unit to the nearest authorized service center SITUATION VERIFICATION LOW OR NO Verify the cleaning tool or the hose for possible obstruction If the hose is SUCTION obstructed try to massage the clog out Try to reverse the hose by OR AIR inserting the cleaning end of the hose in the wall valve and making contact with the two 2 small metal contact pins hold your hand around the opening FLOW AT for air tightness the filter may be clogged if so clean the permanent filter Verify if the debris canister is adequately placed on the unit with no air leaks Verify that all other valves are shut and that there is no air leaks If one of the vacuum valves has noticeably less power than the others it is a sign of a clog at this particular valve Write a different number on a few paper tissues and pick one up in every valve in the home see in the debris canister which one is missing so to find which valve is obstructed If none of the valves function properly and that the power unit is running unhook the flexible pipe on the top of the power unit from the d
13. t it is important to do regular maintenance and cleaning of the filter according to the guidelines listed in this user manual 1 The power unit must be installed in a well ventilated area protected from weathering and away from all sources of heat 2 This central vacuum system is design for dry surfaces only and must not be used on wet surfaces nor be used in any circumstances to pick up liquids or to clean wet carpets or any wet ground 3 The filter cage must be covered at all time by the permanent filter during operation of the system 4 The motor housing must never be obstructed in anyway to prevent damaging or overheating 5 Do not use this system to pick up mud or similar substances To vacuum baking flower talcum powder cement or gypsum dust will have for effect to obstruct and clog the filter media you have to clean the filter several time during and after such pick ups Otherwise the motor will overheat and may be damaged 6 Do not attempt to shorten or modify the power cord in any way 7 AS a safety measure unplug the power cord prior to proceed to maintenance or servicing 8 In order for the warranty to remain valid any repairs or servicing on the power unit must only be performed by an authorized service center 9 The position of the power unit must be so that the power cord and electrical outlet are always easily acessible 10 Pertaining to the use of an electrified valve 110 VAC intended for the connection of
14. ty with the instructions provided in this manual Only use the accessories recommended by the manufacturer Do not use the system if the power cord or if the electrical outlet are damaged if the system does not function normally if it was dropped was left outdoors in bad weather for an extended period of time or if it was immersed in liquid the power unit must be sent to an authorized service center Do not use the power cord to pull or lift the power unit nor use it like a handle Be careful not to pinch it in a door do not let it hang on a sharp corner or edge Examine the openings for foreign objects which may have remained in the pipe If any remove the obstructing objects to ensure maximum airflow Keep the power cord from any contact with any warm objects or surfaces Do not unplug the power cord by pulling on it always remove directly at the electrical oulet Do not use the system or its accessories with wet hands Keep hair clothing fingers any other body parts or other objects out of or away from any openings or moving parts of the system All functions of the system must be deactivated prior to removing the power cord from the electrical socket Take the necessary precautions when using the system in a stairs Do not use the system to pick up flamable liquids or fuels i e gasoline nor use the system in areas where such liquids may be present Only plug in the power cord into properly grounded electr
Download Pdf Manuals
Related Search
Related Contents
On-Chip Thermoelectric Cooling Tool Televisor LCD de 7” (17.8 cm) MET ONE-HHPC-2-Particle-Counter-User-Manual L(名)09080 ミニルーター用先端工具 の特徴と選び方 Severin SM 3799 blender MODO DE EMPLEO PROPIEDADES FÍSICAS SALUD Y Multimedia Interface Bedienungsanleitung Instruction Sencor SHB 3320WH Osiris générique : guide d`utilisation de l`onglet Copyright © All rights reserved.
Failed to retrieve file