1. 2300 Series Monitors Bently Nevada Asset Condition Monitoring Description The 2300 Monitors feature two seismic channels and a speed channel providing continuous monitoring and protection for BOP Balance of plant equipment It is a perfect match for proactively managing your assets rather than waiting until production outages to replace equipment The 2300 series monitors enable condition based monitoring and protection with support for various interfaces and functions Inputs include seismic and speed transducers and outputs include relays buffered output TCP IP Ethernet and an LCD display This monitor is available in 2 versions The 2300 20 which has 2 4 20 mA output and the 2300 25 which supports the Trendmaster SPA line interface The 2300 20 Monitor can be used to replace legacy Bently Nevada monitors such as the 1900 27 but more importantly is a full featured monitor for use monitoring and protecting assets such as motors pumps fans and so on The monitor is software configurable and includes software to display the overall values on a PC There is also an integrated LCD and multiple LEDs to show the channels real time data and status locally Effective plant asset management and particularly effective fleet management of machinery assets often depends on remote access using condition monitoring software such as System1 1 2300 Series will have 4 20mA and Modbus available in mid 2015 2300 25 available i
2. kHz Low pass o Scale Factor range 5 to 1000 mV g o Full scale range 2 to 80g peak o Bias output voltage 12VDC o Configurable Upper OK limit 0 25 to 22 V greater than lower ok o Configurable Lower OK limit 0 25 to 22 V less than upper ok o Current Sink Source 3 3 mA 5 o Open Circuit Voltage 21 to 24 VDC o Accuracy 1 of full scale range e Supports custom accelerometers 2 3 wire Speed Keyphasor Inputs e Supported Keyphasor transducers include o Proximity probe o Proximity switch o Magnetic Pickup e Supports multiple events per revolution and event ratios for speed inputs up to 20 kHz e Threshold voltage resolution 0 1VDC e Proximity Transducer Interface o Supply Voltage 22 8 to 25 2 VDC o Maximum Rated Current 15 mA o Short Circuit Current 15 1 mA to 23 6 mA o Accuracy 1 of full scale range o Input Impedance 3 wire Voltage Mode 10 kQ o Rpm range 1 to 120 000 e Proximity Switch Interface o Supply Voltage 10 to 24 VDC o Lower Not Ok limit 2 75 0 05 V o Rpm range 1 to 120 000 e Magnetic Pick up o Input voltage up to 125V 250Vp p o Rpm range 200 to 120 000 Contact Inputs Monitor provides the capability of 3 contact inputs with terminals One is used for configuration lock one is for alarm reset function and the 3rd one is used for monitor Alarm Relay Inhibit e Activate Oto 10 kQ e De activate 150 kO to infinite Button Inputs e External button to reset a
3. larm and relay e One buried button provides 3 functions o Display monitor information including User account Password IP address FW HW version o LCD contrast adjustment o Reset settings to default including User account name Password Network configuration Jumper between COM amp Chassis GND e There is a 2Pin terminal interface which allows connection of COM and Chassis GND together e Alternatively COM can be connected to earth ground separately through a terminal Buffered Output e There are three buffered outputs available on the monitor through BNC connectors Relay Output e There are 2 dry contact relay outputs e May be normally energized or de energized e Relay circuit specification o Type Single pole double throw Specifications and Ordering Information Part Number 105M0340 01 Rev 10 14 Page 3 of 7 o Sealing Epoxy sealed o Contact life 100 000 cycles 5 amps 250 VAC 200 000 1 amp 24 VDC o Insulation resistance 1000 MQ minimum 500 VDC o Relay closed contact resistance 10 maximum o Relay open contact resistance 1 MQ minimum o Maximum switched contact voltage 400V AC 150V DC o Maximum breaking contact current 6A 250VAC 6A 24VDC o Maximum switched power 1500VA AC 150 Watts DC LEDs e OK Indicates when the monitor is operating properly e Protection fault e User inhibit bypass e Relay status e TX RX Indicates the Ethernet status and monito
4. n mid 2015 Specifications and Ordering Information Part Number 105M0340 01 Rev 10 14 Page 1 of 7 2300 Monitor Key Features Two relay outputs with programmable setpoints 2 4 20mA outputs available on the 2300 20 2 Channel Trendmaster SPA interface on the 2300 25 Ethernet 10 100 Base T communication for connection to System 1 and BNMC The 2300 monitor series also supports Modbus One dedicated speed and Keyphasor channel supporting Proximity probes Magnetic pickup and Proximity switch type sensors Three buffered transducer outputs including speed signal providing short circuit and EMI protection Buffered outputs for each signal are through BNC connectors Available 240 110VAC DIN rail mounted power supplies Continuous monitoring and protection LCD display showing measurements and speed Two acceleration inputs with synchronized sampling for advanced diagnostics Key measurements Direct 0 pk pk pk True RMS Derived pk integrated direct pk real time provided with alarm configuration LEDs show the monitor status Local configuration lockout Package 127 mm x 127 mm x 76 2 mm 5 x 5 x 3 inches Specifications and Ordering Information Part Number 105M0340 01 Rev 10 14 Page 2 of 7 Specifications Inputs Outputs Power Input e DCInput 18 36VDC 6 5 W Supports 2 seismic channels e Supports most ICP accelerometers o Bandpass variable 0 1 Hz High pass 40
5. ng Datasheet and Operation amp Maintenance manual also User Manual 105M0341 01 Operation and Maintenance Manual Specifications and Ordering Information Part Number 105M0340 01 Rev 10 14 Page 6 of 7 Graphs and Figures 1 weesoeooaoaoeond 4 70 119 38 5 36 136 05 The monitor must have 2 5 inch clearance on each side for wiring installation Denotes a trademark of Bently Nevada Inc a wholly owned subsidiary of General Electric Company 2013 Bently Nevada Inc All rights reserved Printed in USA Uncontrolled when transmitted electronically 1631 Bently Parkway South Minden Nevada USA 89423 Phone 775 782 3611 Fax 775 215 2873 www ge mcs com bently Specifications and Ordering Information Part Number 105M0340 01 Rev 10 14 Page 7 of 7
6. r communicating with remote software e Speed channel status e Channel Alarm Status o Alert LED o Danger LED LCD LCD will provide static values and necessary monitor information Environmental Limits Operating Temperature 30 C to 65 C 22 F to 149 F Storage Temperature 40 C to 85 C 40 F to 185 F Humidity Up to 95 non condensing Battery Life for Real Time Clock Powered 38 years 50 C 122 F Un powered 12 years 50 C 122 F Compliance and Certifications General and Electrical Safety UL Std No 61010 1 3rd Edition with May 11 2012 National Differences CAN CSA C22 2 No 61010 1 12 2006 95 EC Low Voltage Standard EN 61010 1 2010 European Community Directives 2006 95 EC Low Voltage EMC Standards EN 61000 6 2 Immunity for Industrial Environments EN 61000 6 4 Emissions for Industrial Environments EN61326 1 Electrical equipment for measurement control and laboratory use EMC requirements EN61326 2 3 Test configuration operational conditions and performance criteria for transducers with integrated or remote signal conditioning European Community Directives EMC Directive 2004 108 EC Communications Ethernet e Ethernet 10Base T and 100Base TX Conforms to IEEE802 3 e BN Protocol using Ethernet TCP IP e RJ 45 for 10Base T 100Base TX Ethernet cabling e Cable length 100 meters 328 feet maximum Hazardous Area Approval
7. s Approval Option 01 CSA Canada and U S Class 1 DIV 2 Zone 2 ATEX II 3G Ex nA nC ic IIC T4 Gc IECEx Ex nA nC ic IIC T4 Gc For further certification and approvals information visit the following website www ge mcs com bently Specifications and Ordering Information Part Number 105M0340 01 Rev 10 14 Page 4 of 7 Physical Dimensions Width x Depth x Height 127mm 5 in x 127mm 5 in x 76 2mm 3 in Weight 1 03kg 2 26 Ibs Mounting Panel mount or DIN rail adapter included 2 Commtest accelerometer sensor 2 4 8M accelerometer cable Excluding keyphasor sensor enclosure and 24 VDC power supply BB Approvals 01 C1D2 ATEX IECEx Ordering Information 2300 20 AA Monitor with 4 20ma Outputs including DIN rail mount assembly manual and monitor configuration software AA Approvals 01 C1D2 ATEX IECEx 2300 20_KIT AAA BB Bently Nevada 2300 20 Condition Monitoring System Kit AAA Configuration 001 1 Monitor 2300 20 1 6 ft shield Ethernet cable 1 14x12x8 fiberglass housing with window 2 Commtest accelerometer sensor 2 4 8M accelerometer cable Excluding keyphasor sensor and 24 VDC power supply 002 1 Monitor 2300 20 1 6 ft shield Ethernet cable 1 14x12x8 fiberglass housing with window 1 Commtest accelerometer sensor 1 4 8M accelerometer cable Excluding keyphasor sensor and 24VDC power supply 003 1 Monitor 2300 20 1 6 ft shield E
8. thernet cable Accessories 105M6193 01 Fiberglass NEMA 4X IP68 weatherproof housing with window in door includes mounting plate for monitor 104M9881 Power supply 110 220 VAC to 24 VDC DIN mount AM3100T2 Z2 Commtest Accelerometer sensor 100M0741 Proximity Switch 284947 Magnetic Pickup Proximity Probes Please refer to proximity probe datasheet 141194 01 for details 02120015 Bulk Cable from Proximity sensor to monitor 500 feet CB2W100 AAA Cable for accelerometer AAA 015 15 feet 4 8 m 032 32 feet 9 8 m 064 _ 64 feet 19 5 m 112 112 feet 34 1 m 125 125 feet 38 1 m 150 150 feet 45 7 m 200 200 feet 61 0 m 250 250 feet 76 2 m 286244 Magnetic Mounting base 28 threaded hole 105M6203 01 Spare 35mm DIN rail mount and screws included with 2300 20 monitor Ethernet Cables Standard 10 Base T 100 Base TX Shielded Category 5 Cable with RJ 45 connectors solid conductor 138131 AAA AAA Cable Length 006 6 feet 1 8 m Specifications and Ordering Information Part Number 105M0340 01 Rev 10 14 Page 5 of 7 010 025 040 050 075 085 100 120 150 200 250 320 10 feet 3 0 m 25 feet 7 6 m 40 feet 12 2 m 50 feet 15 2 m 75 feet 22 9 m 85 feet 25 9 m 100 feet 30 5 m 120 feet 36 6 m 150 feet 45 7 m 200 feet 61 0 m 250 feet 76 2 m 320 feet 97 5 m Software 100M9465 01 BN Monitor Configuration SW DVD Version 4 0 or greater DVD includi

Download Pdf Manuals

image

Related Search

Related Contents

FT - Phobi Fénox VR 04.2014  FREQUENTLY ASKED QUESTIONS (FAQ) ON E  Bibliothèques - La Seyne-sur-Mer  Simile - Direction For Use  PJ Network Manager (Francais)  ASUS EE8213 User's Manual  1 - Apex Power Tools  PIANO DI SICUREZZA E COORDINAMENTO  CAUTION! - SpyCameraCCTV  Quartz Analogue Operating Instructions  