user manual issue D4.qxp:user manual grey 08-10

image

Contents

1. gt DID S gt SED 5 Fae ol ep beses eee eee OO 120 00 92 10 92 10 92 10 92 10 92 10 S 647 00 _ 120 00 92 00 92 00 92 00 92 00 92 00 TT TTT o 8 o 2 o RIL L 177 00 Left side view Top view Right side view Left side view Top view 2 ght side view Front view door closed Front view door closed Maintenance Modern computer systems can generate a large amount of heat within the chassis The internal temperature of the chassis is kept within operating limits by forced air cooling Most systems have a number of fans which must be maintained to allow free airflow Some of our chassis have air intake fan filters which prevent contaminants from entering the inside of your system End of Life Battery Removal Instructions Warning All power connections must be removed before Caution Blocked fan filters may result in your system overheating and being damaged Preventative Maintenance Clean the fan filters periodically to ensure that the air circulating in the unit is clean Wash the filter with warm soa
2. 00 892 E 00 89 l a c Ed 207 00 195 00 219 00 07 00 9 00 mmn Front outside view i Top view 80 00 86 00 Right side view Impact E 52 57 Design Rugged compact embedded design Cooling Fanless design 52 only Construction Heavy duty aluminium Colour Black custom colours available for large orders Dimensions 195 W x 107 H x 268 D mm Packaging dimensions 310 W x 240 H x 360 D mm Gross weight Approximately 4 7kg Packaged gross weight Approximately 6 8kg The Impact E 57 incorporates a 40mm industrial fan to cool any fitted PCI cards Rear outside view 195 00 219 00 207 00 195 00 268 00 268 00 Front outside view Top view Right side view Impact S IP CCTV Storage Servers The Impact S storage servers have been specifically designed to meet the requirements of IP surveillance applications such as DVR NVR and IP CCTV systems These systems are tailored to specific customer requirements to achieve the desired resolutions and frame rates Adding additional cameras to the network or increasing the performance settings in your software
3. Dimensions 483 W x 88 H x 450 D mm 19 0 x 3 5 x 17 7 Packaging size 615 W x 224 H x 600 D mm 24 2 x 8 8 x 23 6 Total drive capacity 1 x Slim 5 25 external 1 x 3 5 external 4 x 3 5 internal or 1x 5 25 external 1 x 3 5 external 3 x 3 5 internal Cooling 3 x 80mm ball bearing fans 42 5 CFM each Air filter removable washable Gross weight approximately 17kg Rear out side view m A k 01777777 E a d nr S Left Inside View 44 00 Right View ole Tel I 9 y rer oe o L L 0 Xxxx LLLA S s 00000000000000 00000000000000 S BoSS 2 R WU E E Wd E E 88 00 _ 0 9 07 o ATX Mothboard Size 12 x9 6 S H l 25 A d 6 e HE x 3 a e Front out side view 3 5 FDD q o z le Rrip ST i o q 1 U OC 2 i z 30 Hee i SL nen Front in side view ats CD ROM d i pE H 3 5 HDD LJ I EP Impact Impact R 3xxx Impact S 3000 Series Chassis Design EIA RS 310C 19 Rackmount Standard Construction 1 2mm SECC Zinc Coated Steel Colour B
4. gt 20kg Ventrix Impact 4xxx 4U gt 20kg Ventrix 5xx 5U gt 17kg Ventrix Impact 6xxx 6U gt 30kg Ventrix W 4U gt 20kg Impact S 2000 2U gt 20kg Impact S 3000 3U gt 20kg Impact S 4000 4U gt 40kg Impact S 6000 6U gt 70kg Impact N 4U Tower gt 30kg The weight of a system will increase when it is expanded The weight of additional drives and plug in cards must be considered Warning When heavy equipment is extended on its slide rails there is a danger that the rack could topple over We recommend that the rack is secured to the floor or a suitable stabilising plinth is used Introduction Thank you for purchasing your Industrial Computer from Amplicon Liveline Limited Your system has been assembled from quality components selected by our engineering team For increased reliability all our systems undergo a diagnostic test If you have specified an operating system this will be installed together with any additional plug in cards or software When you unpack your system you will find Amplicon CD containing this manual and drivers A manual for the industrial single board computer or motherboard Any specified plug in card driver disks and manuals Any specified device software such as Nero or Easy CD Creator Additional screws and fixings pack Any specified keyboard and mouse Y splitter Power cord Any specified keyboard mouse or trackball Keys Contents may
5. A A A A A A A E 2 2 2 2 2 2 2 2 2 A 2 2 G E s SEE Ba A ee SB UU 19 E SD TEE aun T Lap L anm Rear view 132 00 172 00 Left side view Impact E 42 Design Rugged compact embedded design Cooling Fanless design Construction Heavy duty aluminium Colour Black custom colours available for large orders Dimensions 195 W x 80 H x 268 D mm Packaging dimensions 310 W x 240 H x 360 D mm Gross weight Approximately 4 4kg Packaged gross weight Approximately 6 5kg Rear outside view 9 00 RONDS 195 00 07 00 195 00 86 00 80 00 00 98 00 08 00 08 00 98 00 892 00 79g UU T Z 00 78T p 195 00 Wii enw 0038 0008 300 5665 300i 0008 00 98 UU TES
6. g y o o ge i o e ON OD Rear view S CT 2 s i G 2 D in CU 8 8 o oN ai o o ICH T LS oe Ll i ial 0 0 AR o S ig Only 12FAN 108cfm ft J u o o o B8 88 88 88 e FAN D r nm LE e e g eelle e fe o _ D K 1 s T Z T T 1 e FN 08 88 88 88 i a O O L Ny L d g i Top view l CA n DE Left side view Right side view z I I I i amp Wooo y o Top View a 482 60 464 60 i Right side Vi side View S r RS 7 ie g ol ollie ible lia mtm SI id ASG E BO a ERE AGT LO GSI R DO DO GOD Do1 HOC ON nc Am cA DOD iad Ono Senn eegee g SESI E HET TTS Le oO o u U a Sq bo 4 Rad fag Ae Peg BS 102 177 o o o o o O 267 00 OOO LL b 5 ra S SSeS Soil F mm rel i Front out side view a 7 i 7 Front in side view Front inside view Front outside view Rear outside view Ventrix W 4xxx Series Chassis Des
7. 19 0 x 3 5 x 22 1 Packaging size 570 W x 220 H x 735 D mm 22 4 x 8 7 x 28 9 Total drive capacity 2 x 5 25 external 1 x 3 5 external 4 x hot swap 3 5 SATA Cooling 3 x 80mm dual ball bearing fans 42 5CFM each Gross weight approximately 20kg 427 00 M ZE SI st r S S f Na CQ 2 o S Ss S J 13 2 qom h 232 N 2 Rear view 9 eS Q a 000000000 ao e o 00000000000 S T Ww oO N o H oo cT s D I HI 2 S u a Lll L ee i DODAO RASO ES o s Fr Front view door open EF On 1 482 60 o s 466 60 2 ri S K G ee 2 Z Z Z ES d Pp LEL 2 Left side view TOPVIEW Right side view Front view door closed Impact Server 4000 Series Impact Server 6000 Series Design EIA RS 310C 19 Rackmount Standard Design EIA RS 310C 19 Rackmount Standard Construction Heavy duty cold rolled electroplated steel Construction Heavy duty cold rolled electroplated steel Colour Black with
8. 2 splitter must be used when attaching a keyboard and mouse Upgrading and Expanding the Impact E Series The Impact E series are sold pre configured as fully working systems To access the inside of the unit remove either the six top cover or base plate screws Your system will come supplied with a processor and memory We do not recommend that you replace these components without contacting us for advice Removing the top will give access to Memory 2 x 1GB 240 pin DIMM DDR2 667 SDRAM Max Internal CompactFlash socket Internal CompactFlash socket Removing the top will give access to Hard drive mounting A 2 5 parallel IDE hard drive may be added to the system Ensure that the heat transfer plate makes good contact with the side of the chassis when fitting The Impact E 42 52 57 can accept PCI expansion cards of limited length Regulatory Compliance CE Marking We have run our own fully equipped EMC Pre compliance facility for over ten years This facility is used to ensure the ongoing conformance of our products to the EMC Directive 2004 108 EC As standard our systems meet or exceed the requirements of IT Equipment as defined in the Harmonised Product Standards for Information Technology Equipment As the majority of our customers work within industry most of our products meet Class A Emissions We can also taylor testing packages to ensure equipment meets the requirements of many other standards suc
9. 20kg CeL eC eC eC kC PEPE PEPE PEPE kC eC eC eC rC eC eC AIR AIR 5 5 OUT OUT S RLRE FAN 00000000000000000000000000000000000000000000000000 Cd k i POWER e 9 9999909099999999 0 9 o o o ATX a o OY B 9090909099090909 09 G o o FS a g o amp
10. EO d S C G S TTS a POWER om s Sq Sree es 5 a 0 o S m as x k 8 Rear out side view HI a Po o oN S o 2 Ea 3 HS 38 hj Lissa FJ S E EDD S epy aS l Ta fo 0 a d l JU o o oS Air Filter SACEM g Front out side view 73 5 HDD Left Inside View Top View Right View 482 60 466 60 WW hDMGGI LLLA MMMM EE o o 1 MU G Front in side view Ventrix 4xxx Series Chassis Ventrix 6xxx Series Chassis Design EIA RS 310C 19 Rackmount Standard Design EIA RS 310C 19 Rack esign S 310C ackmount Standard Construction Heavy duty cold rolled electroplated steel Construction Heavy duty cold rolled electroplated steel KAGEN p Colour Black custom colours available for large orders Dimensions 483 W x 267 H x 463 D mm 19 x 10 5 x 18 2 Packaging size 610 W x 418 H x 647 D mm 24 0 x 16 5 x 25 5 Total drive capacity 4 x 5 25 1 x 3 5 HDD 1 x 3 5 floppy disk drive Cooling 4 x 90mm fan 90 CFM each Air filter removable washable Colour Black custom colours available for large orders Dimensions 480 W x 177 H x 510 D mm 19 x 7 x 20 1 Packaging size 600 W x 345 H x 690 D mm 23 6 x 13 6 x 27 2 Total drive capacity 4x 5 25 1x 3 5 FDD Cooling 1 x 120mm fan 108 CFM Air filter removable washable Gross weight approximately 30kg Gross weight approximately
11. PC system ensure you carefully read through this manual and follow any related safety or operational instructions Only suitably qualified and experienced personnel should work inside the computer Before commencing work within the PC ensure that the mains is disconnected from the PC and any attached peripherals Operation of your PC Before operating your computer please Read the equipment ratings plate and ensure that the mains circuit is suitably rated to power the equipment to avoid risk of overloading Do not use mains adaptors or extenders Ensure that any cables connecting to the equipment are made safe and do not present a tripping hazard To avoid risk of electric shock ensure that equipment is plugged into a suitably grounded mains outlet Only use the power cord supplied with your PC Do not continue to use the cable if it is cut or damaged Ensure the chassis is kept away from heat sources such as radiators and heating vents Chassis ventilation slots must be kept clear and not blocked Failure to do so is likely to cause the unit to overheat and become unstable Avoid connecting the PC to an electrical supply which may have unacceptable interruptions surges spikes or noise We recommend the use of an uninterruptible power supply UPS surge protector or mains conditioner to address the issue Electrostatic Discharge Damage When working on the inside of a PC system you must be aware that many of the components
12. VAC Full Range 47 63 Hz 14 0A for 115 VAC 7 0A for 230 VAC 80 Plus Certified Standard 460W 460W Dual Redundant IPR P460FVS Active PFC Voltage Frequency Input Current 90 264 VAC Full Range 47 63 Hz 8 0A for 115 VAC 4 0A for 230 VAC Standard 1350W N 1 Redundant M1W4 6D50P Active PFC Voltage Frequency Input Current Inrush Current 90 264 VAC Full Range 47 63 Hz 20 0A for 115 VAC 10 0A for 230 VAC 60A Max for 115 VAC 100A Max for 230 VAC Mechanical Specifications Ventrix Range The Ventrix series utilise single board computer SBC and complementary backplane technology All our Ventrix products have a typical life cycle of five years This series provides a wide performance range to meet different application needs In addition each model is offered with a choice of PCIISA PCI express expansion options Systems can be specially customised All of our Ventrix products use Intel processors supported by the Intel Embedded Roadmap Ventrix 1xxx Series Chassis Design EIA RS 310C 19 Rackmount Standard Construction Heavy duty cold rolled electroplated steel Colour Black custom colours available for large orders Dimensions 483 W x 44 H x 450 D mm 19 x 1 7 x 17 7 Packaging size 615 W x 179 H x 600 D mm 24 2 x 7 0 x 23 6 Total drive capacity 1 x slim CDROM 2 x 3 5 HDD 1 x slim 3 5 floppy disk drive Cooling 3 x 40mm fan 7 CFM each Gross weight ap
13. Windows XP FeS Recovery Disk Customers who have purchased systems with Windows XP Professional for Embedded Systems FeS installed will not have been supplied a Microsoft Windows media disk In the unlikely event that you have encountered a problem with your hard drive which necessitates a system restore you should contact our support team who will arrange for a System Restore Disk to be shipped to you Our industrial systems feature a range of high reliability 24 7 duty hard drives We do not supply a System Restore Disk with every copy of Windows XP Professional for Embedded Systems FeS Caution The recovery disk will wipe all data and set the machine back to factory default Amplicon Generic Recovery Disk Instructions The Amplicon Recovery DVD includes licensed software It has been supplied solely to facilitate the recovery of a single PC system and cannot be used with any other system or device If you require additional recovery disks you must contact the Amplicon Support Team This Generic disk includes all the drivers for the motherboard or single board computer and has been created using the Microsoft Sysprep utility It does not include drivers for additional plug in cards or customer specific software or settings You will need to run through a limited setup procedure before you can start using the machine During this process you will need to enter the OEM key displayed on the Windows Licence Sticker and also run thr
14. a Y splitter cable to breakout the keyboard and mouse PS 2 connections from the single connector on the The system resource requirements for plug in cards vary It is recommended that you system Connect this cable to the rear PS 2 connector The mouse and keyboard check the resources required by your card s are available Please refer to the connections are clearly marked on the cable processor board manual supplied with your system USB devices are designed to be hot plugged and may be connected when the system is running Once all the devices are connected the mains power outlet can be switched on Remove the chassis cover retaining screws to gain access to the inside of the system and the unit turned on If your system is fitted with a card retaining clamp remove the screws securing it and We supply both AT and ATX powered systems AT systems have latching power switches ete won he adal and need to be manually switched off The ON position is denoted by a I and OFF by a 0 ATX systems have a momentary push button and can be automatically shut down by Locate the position where you wish to insert your new card and remove the screw and most modern operating systems To turn the unit off manually depress and hold the blanking plate power switch for four seconds If your computer has a rear PSU power switch this must also be switched to ON before the system can be powered Insert you new card ens
15. to 50 C with a 2 5 HDD or 0 to 55 C with a CompactFlash card or solid state drive The exact specification of each model can be found on the appropriate datasheet These systems have a DC input with selected models being supplied with an external AC adaptor The DC input range of these systems typically ranges between 12 to 30 volts but they are not suitable for direct connection to a vehicle battery supply A 12V car battery can drop to as little as 6 volts when the starter motor is in operation In addition the large inductance of the alternator can cause surges which will damage these systems If you are intending to use one of these units in a vehicle you need to fit a suitable regulated DC DC supply Impact E 20 Design Rugged compact embedded design Cooling Fanless design Construction Heavy duty aluminium Colour Black custom colours available for large orders Dimensions 260 W x 55 H x176 D mm Packaging dimensions 290 W x 180 H x 380 D mm Gross weight Approximately 2 5kg Packaged gross weight Approximately 3 4kg Top view 176 00 172 00 132 00 92 00 Front view AIIILNINNASNNNANNINIIIVIIG O LAA o B hn ae 5 gt LE_ come COMS come com a P OTL 00787 N N S S y y y S S S S S S 9 S y y y S y y NS S S
16. will affect recording rates Entry level systems utilise the integrated Intel onboard RAID These systems can only support up to a maximum of 2TB in any one partition When using the integrated RAID controllers a third party RAID controller card cannot be used in the system Higher specification systems utilise Adaptec 3000 and 5000 series RAID controller cards These systems support both SAS and SATA hard drives Only the same type capacity of hard drive can be grouped to form RAID array Adaptec RAID 31605 Controller e 16 internal ports e Intel 80333 800MHz processor e 8 Lane PCI Express bus interface e RAID levels O 1 1E 5 5EE 6 10 50 60 JBOD e 256MB cache e Adaptec Storage Manager e Copyback Hot Spare e Battery backup optional Adaptec RAID 3805 Controller e 8 internal ports e MD2 Low profile form factor e Intel 80333 800MHz processor e 4 Lane PCI Express bus interface e RAID levels O 1 1E 5 SEE 6 10 50 60 JBOD e 128MB or 256MB cache e Adaptec Storage Manager e Copyback Hot Spare e Battery backup optional For further information related to the RAID controller or management software please refer to the separate manual supplied Impact Server 2000 Series Design EIA RS 310C 19 Rackmount Standard Construction Heavy duty cold rolled electroplated steel Colour Black with orange front door OEM branding service available Dimensions 483 W x 88 H x 560 D mm
17. 2 0 Total drive capacity 2 x 5 25 1 x 3 5 HDD 1 x 3 5 floppy disk drive Cooling 1 x 120mm fan 90 CFM Air filter removable washable Gross weight approximately 17kg e D Rear View MINI REDUNDANT 0 ooo 0 00 0 0 ooo OD OOO D Top View 350 00 411 20 Front View 177 00 Side View Impact Impact R Range The Impact R series incorporates DFI industrial motherboards to achieve hardware life cycles of up to five years These models provide a wide performance range to meet different application needs The Impact range is designed and built by Amplicon under ISO09001 2008 quality management procedures They offer premium value and provide a bridge between business and top end industrial systems Every Impact is constructed in heavy duty steel chassis built to industrial standards All of our Impact R and Impact products use Intel processors supported by the Intel Embedded Roadmap Impact Impact R 2xxx Series Chassis Design EIA RS 310C 19 Rackmount Standard Construction Heavy duty cold rolled electroplated steel Colour Black custom colours available for large orders
18. 222 gal 12225 le e EJ lems os gt Oc a B 229222 S CSS 1 3 a T 5 ee oF Pol SSeS 3 5 gt gt S Se Sa co SSSSe2 O 5 4 a T oe K L a en G E a ES r ESS GE Ss DOT SS Ss ES g EE l aa oc fae oa ee g i Sao gt oo oS eS m se Sl JB E l 2822853 gore au Q Front inside view 465 00 Bm 485 00 Front outside view Impact R 15x Series Chassis Design Compact desktop wallmount brackets supplied Construction Heavy duty cold rolled electroplated steel Colour Black Silver Custom colours available for large orders Dimensions 280 W x 77 H x 268 D mm 11 0 x 3 0 x 10 6 Packaging size 373 W x 363 H x 175 D mm 14 7 x 14 3 x 6 9 Total drive capacity 1 x Slim 5 25 external 2 x 2 5 internal Cooling 1 x 60mm ball bearing fan 23 5 CFM Gross weight approximately 4kg 279 4 mm Front outside view 267 3 mm Oeeoso0 d 525085 oo00880080 0000000000 ISSE 200000000 wooooooood 0000888000 0000 oscae20 0o o0 wo ee ae eel le Impact R 2xx Series Chassis Design Compact desktop wallmount brackets supplied Construction Heavy duty cold rolled electroplated stee
19. Amplicon Computer user manual Contents 03 03 04 04 06 07 08 09 11 12 14 15 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 Safety Instructions Operation of your PC Electrostatic Discharge Damage Rack Mounted Equipment Introduction Unpacking the system Installation Fitting ISA PCI and PCI express Cards Impact E 42 52 57 Accessories Upgrading and Expanding the Impact E Series Regulatory Compliance Specifications Mechanical Specifications Ventrix Range Ventrix 1xxx Series Chassis Ventrix 2xxx Series Chassis Ventrix 4xxx Series Chassis Ventrix 6xxx Series Chassis Ventrix W 4xxx Series Chassis Ventrix 5xx Series Chassis Impact Impact R Impact Impact R 2xxx Series Chassis Impact Impact R 3xxx Impact S 3000 Series Chassis Impact Impact R 4xxx Series Chassis Impact R 15x Series Chassis Impact R 2xx Series Chassis Impact E Range Impact E 20 Impact E 42 Impact E 52 57 Impact S IP CCTV Storage Servers Impact Server 2000 Series 36 37 38 39 40 41 41 42 43 Impact Server 4000 Series Impact Server 6000 Series Maintenance End of Life Battery Removal Instructions Product Repair Returning a Unit to Amplicon Amplicon Windows XP FeS Recovery Disk Amplicon Generic Recovery Disk Instructions Generic Recovery Disk Process Terms and Conditions End of Life Processing Safety Instructions Before you unpack your
20. a quick release clip or soldered in place If they are soldered they should be removed by cutting the component legs See page 39 for details This page is blank Amplicon Centenary Industrial Estate Brighton UK BN2 4AW C 44 0 1273 570 220 44 0 1273 570215 i sales amplicon com R wvww amplicon com International Sales C 44 0 1273 608 333 IT and instrumentation for industry The information contained has been reviewed and is believed to be accurate and reliable however Amplicon Liveline Limited accepts no responsibility for any problems caused by errors or omissions Specifications and instructions are subject to change without notice Computer User manual Part No 85040046 Issue D4 Amplicon Liveline Limited Prepared by R Cobden Engineering Manager
21. address details to hand Please ensure you read our Terms and Conditions which cover our On site Maintenance End of Life Processing The requirements of WEEE Waste Electrical and Electronic Equipment apply to this product You the customer are the final user as defined by this Regulation If you purchase replacement equipment from Amplicon we shall bear the cost of removal and proper disposal of this product Amplicon s WEEE Producer Registration Number is available on our website htto Awww amplicon com info ROHS cfm Required Tools For Dismantling No 1 Phillips screwdriver Nut spinner 5mm Light gauge wire cutters Dismantling Procedure Our systems can easily be dismantled using the tools listed All mechanical fixings are made by M2 M3 and M4 screws or threaded posts Wire cutters are required to cut the plastic cable ties and any other plastic cable management Locate the top cover and remove the securing screws Once the cover is removed you will be able to see within the unit The system can easily be broken down into the following components Metal chassis parts electron galvanised steel Printed circuit board assemblies fibreglass PCB material Chassis fans Plastic resin and electronic components Some systems are fitted with batteries such as lithium used for system CMOS backup Make sure these are removed in the first instance and disposed of in an appropriate manner Batteries will be either retained by
22. are electrostatic sensitive discharge ESD These components can easily be damaged if suitable precautions are not taken ESD damage is not always immediately apparent and may result in a failure many weeks later When working on equipment we recommend the use of an ESD mat and wrist strap Caution Components inside of the case can be damaged by f b electrostatic discharge ESD You must take suitable precautions to prevent likely ESD damage Rack Mounted Equipment Please read this section carefully before assembling your industrial computer as part of an enclosure or multi rack assembly It is highly recommended that any work of this nature only be undertaken by competent trained personnel These guidelines must be read in conjunction with the user guide of the enclosure and any other equipment to be fitted The maximum ambient operating temperature should not typically exceed 40 C The operating ambient temperature of the rack environment may be greater than room temperature The direct ambient environment must not exceed the maximum rating Allow free airflow around the chassis for safe operation Place any fans or blowers close to the heat generating devices If using a fan ensure that outside air is not brought inside the enclosure unless a fabric or other reliable filter is used This filtration prevents conductive particles or other harmful contaminants from entering the enclosure Ensure the rating of the mains power outle
23. h as Railways or London Underground If you require a CE Declaration a member of our support team will be happy to provide you with a copy If you require additional testing or have any questions concerning product conformance please contact our Engineering Manager Specifications Electrical Ratings PLUGGABLE EQUIPMENT The socket outlet shall be installed near the equipment and shall be easily accessible Always check the ratings plate of your system for the correct specifications Our systems incorporate Zippy industrial power supplies PSUs The following models are standard for many of our systems Standard 300W Flex ATX Flex 0130B Active PFC Voltage 100 240 VAC Full Range Frequency 50 60 Hz Input Current 6 0A for 100 VAC 3 0A for 240 VAC Standard 460W HP2 6460P Active PFC Voltage 90 264 VAC Full Range Frequency 47 63 Hz Input Current 7 0A for 115 VAC 3 5A for 230 VAC Inrush Current 65A Max for 115 VAC 125A Max for 230 VAC Standard 600W PSM 6600P Active PFC Voltage 90 264 VAC Full Range Frequency 47 63 Hz Input Current 10 0A for 115 VAC 5 0A for 230 VAC Inrush Current 65A Max for 115 VAC 125A Max for 230 VAC Standard 680W IPS P680TNMI S Active PFC Voltage 90 264 VAC Full Range Frequency 47 63 Hz Input Current 10 0A for 115 VAC 5 0A for 230 VAC 80 Plus Certified Standard 880W IPS P880TNMI S Active PFC Voltage Frequency Input Current 90 264
24. ign EIA RS 310C 19 Rackmount Standard Construction Heavy duty cold rolled electroplated steel Colour Black custom colours available for large orders Dimensions 483 W x 177 H x 510 D mm 19 x 7 x 20 1 Packaging size 591 W x 340 H x 688 D mm 23 3 x 13 4 x 27 1 Total drive capacity 1 x 5 25 3 x 3 5 HDD Caddy SATA SAS amp SCSI320 available Cooling 3 x 92mm fan 51 CFM each Gross weight approximately 20kg 482 60 mo Keyboard amp Mousepad drawer Front out side view Rear out side view 427 00 AIR OUT Hold Down Bar 3 5 HDD 5 25 CD ROM o o o oo o Left side View Top View Right side View Ventrix 5xx Series Chassis Design Desktop or wall mount Construction Heavy duty cold rolled electroplated steel Colour Black custom colours available for large orders Dimensions 350 W x 411 H x 177 D mm 13 8 x 16 2 x 7 0 Packaging size 490 WV x 324 H x 558 D mm 19 3 x 12 8 x 2
25. l Colour Black Silver custom colours available for large orders Dimensions 350 W x 90 H x 268 D mm 13 8 x 3 5 x 10 6 Packaging size 470 W x 390 H x 235 D mm 18 5 x 15 4 x 9 3 Total drive capacity 1 x Slim 5 25 external 2 x 2 5 internal or 1 x 3 5 internal 1 x 2 5 internal Cooling 2 x 60mm ball bearing fans 23 5 CFM each Gross weight approximately 6kg Top view N O U O U O 350 0mm 90 0 mm Front outside view Left side view 269 0 mm Impact E Range Rugged Industrial Computers The Amplicon Impact E range of embedded computers provide a compact and robust platform The elimination of cooling fans allows these systems to achieve a typical MTBF of gt 50 000 hours 25 C The fanless systems are typically rated for an operational ambient temperature of 5 to 45 C with a 2 5 HDD or O to 50 C with a CompactFlash card or solid state drive fitted However the ambient temperature specification is based on a typical airflow and should only be used for guidance A more precise way to ensure the system is working within specification is to measure the case temperature specifically the centre of the top case with a surface probe The environmental specification is highly dependant upon a number of factors such air movement around the case processor loading and what expansion is fitted Case temperatures are rated at 5
26. lack custom colours available for large orders Dimensions 483 W x 133 H x 526 D mm 19 x 5 25 x 20 7 Packaging size 588 W x 285 H x 703 D mm 23 1 x 11 2 x 27 7 Total drive capacity 2 x 5 25 1 x 3 5 external 4 x 3 5 internal Cooling 1 x 80mm 2 x 92mm ball bearing fan 42 5 51 0 CFM Air filter removable washable Gross weight approximately 18kg TX Mothboard Size 12 x9 6 ll i gt gt 1 U Front in side view 92 0 MINI REDUNDANT POWER rela o Je onoo G WWW 2 SIBI B ULL z c Wy 1 ay SS Front out side view 465 0 Left side View Top View Right side View 1850 Impact Impact R 4xxx Series Chassis Design EIA RS 310C 19 Rackmount Standard Construction 1 2mm SECC Zinc Coated Steel Colo
27. n be removed without any special tools The vertically mounted carrier holds the button cell in place with a spring clip To release the battery push the clip to one side When the clip is clear of the battery you will be able to pull the battery free of the carrier You can apply pressure to the clip with a device such as a pen or use your finger The horizontal carrier has a spring located underneath the battery which will eject the button cell once the clip is pushed clear off the battery Apply pressure to the clip with a device such as a pen or by using the tip of your finger Product Repair Returning a Unit to Amplicon If you are encountering technical difficulties with your system please contact our Technical Support Team Free technical support is provided throughout the warranty period of the product You can reach our Technical Support Team during the hours of 08 30 to 17 30 GMT via Telephone 44 0 906 293 0293 Fax 44 0 1273 570 215 Web www amplicon com Email support amplicon com Calls cost 25p per min from a BT landline Calls from other services may vary An online support request form is available form our website When calling please ensure that you have your company details purchase order details and serial numbers to hand No goods should be sent back to Amplicon Liveline Limited without obtaining a Returns Materials Authorisation RMA number prior to shipment Amplicon
28. oam Retain the packing foam with the other packing materials The chassis top cover can now be replaced and secured with the original screws Caution Powering the system without removing the internal transit packing foam will result in damage Installation Making connections to your computer Our range of industrial computers utilise either single board computers or conventional ATX form factor motherboards The exact positioning of each connector may vary slightly for your specific machine For detailed information please refer to the processor board manual supplied with your system Fitting ISA PCI and PCI Express Cards The following instructions describe the physical installation of ISA PCI or PCI Express PCle plug in cards Please refer to the internal view photographs overleaf Disconnect the mains power from your system It is recommended that you leave the power cord attached but isolate the live mains feed from the power outlet This method will retain a protective earth to the chassis Use an anti static wrist strap to avoid electrostatic discharge ESD damage to the system and plug in card Ensure that the mains power outlet is switched off and connect the mains power cord Connect the external devices whilst referring to the connections shown in the E When selecting a plug in card ensure that there is sufficient mechanical clearance photographs below Some single board computer based systems use
29. orange front door OEM branding service available Colour Black with orange front door OEM branding service available Dimensions 483 W x 177 H x 650 D mm 19 0 x 7 0 x 25 6 Dimensions 483 W x 265 H x 666 D mm 19 0 x 10 4 x 26 2 Packaging size 854 W x 336 H x 576 D mm 33 6 x 13 2 x 22 7 Packaging size 855 W x 418 H x 610 D mm 33 7 x 16 5 x 24 0 Total drive capacity 1 x Slim CDROM 2 x 3 5 internal 16 x hot swap 3 5 SATA Total drive capacity 1 x Slim CDROM 2 x 3 5 internal 32 x hot swap 3 5 SATA Cooling 3 x 120mm 90 CFM each 2 x 60mm 23 5 CFM dual ball bearing fans Cooling 2 x 120mm 90 CFM each 5 x 60mm 23 5 CFM dual ball bearing fans Gross weight approximately 40kg Gross weight approximately 70kg A Warning Heavy Item A Warning Heavy Item 427 00 F ON ONI KON FONT oN KOST FOS ON Rear view G TH L L 2 ze OD gt 665 80
30. ough Windows Activation After the setup is complete you will be able to install any required additional drivers or software Generic Recovery Disk Process Enter the PC BIOS screen by pressing either the Delete or F2 key this varies between hardware as the machine boots Set the first boot device to the DVD drive Insert the Recovery DVD and let the machine start up Paragon System Recovery 1 Paragon System Recovery will 2 To accept the disk wipe and load and take a few minutes to recovery click in the box and then detect the hardware select Next 3 Paragon System Recovery will 4 When the recovery process has now start to recover the system finished you will be prompted to and show a progress bar eject the disk and the system will then re boot NOTE The recovery disk is not compatible with a RAID volume Terms and Conditions Our Terms and Conditions are available to view or download at the following link http Awww amplicon com terms pdf On site Maintenance This chapter is only applicable to systems supplied with one of our on site maintenance contracts Before requesting an on site visit you must discuss your issue with a member of our Technical Support Team If we are unable to resolve your problem over the phone we will arrange an on site visit in line with our Maintenance Service Terms and Conditions of Service When wishing to arrange a visit please ensure you have the correct and full
31. proximately 8kg Rear view Full Card 1 Left Side Slim FDD Slim CD ROM 450 00 Top View 482 60 Right View Left View 1 466 60 j 9 S gt HMllddlddddddddldlddlddddddddddd o Zeal ANNANN Front view door closed Front view door removed 43 40 80 31 Ventrix 2xxx Series Chassis Design EIA RS 310C 19 Rackmount Standard Construction Heavy duty cold rolled electroplated steel Colour Black custom colours available for large orders Dimensions 483 W x 88 H x 450 D mm 19 x 3 5 x 17 7 Packaging size 630 W x 248 H x 574 D mm 24 8 x 9 8 x 22 6 Total drive capacity 1 x 5 25 1 x 3 5 FDD or 1 x Slim CDROM 1 x 3 5 HDD 1 x 3 5 FDD Cooling 3 x 80mm fan 42 5 CFM each Air filter removable washable Gross weight approximately 20kg 427 00 44 i U 2 s G g eo etme s o n j
32. py water and eave it to dry flat Do not scrub the filter and do not install it into the unit until it is completely dry Base your maintenance schedule on the operating environment of the system If the area is dusty you should schedule maintenance more often than if it is a dry and clean area Check the filter often to determine if it needs to be changed ahead of schedule Remove dust and dirt from system components If dust builds up on heat sinks and circuitry an obstruction of heat dissipation could cause the unit to malfunction If dust reaches the electronic boards a short circuit could occur Check the connections to input output modules especially in environments where vibration could loosen the connections and ensure that all plugs sockets terminal strios and module connections are secure Ensure that air intake and exhaust points are free from obstructions Stock spare parts to minimise down time resulting from part failure Whether it is a custom or off the shelf spares package we can provide a solution dismantling your PC system Use anti static precautions The range of industrial PC products supplied by Amplicon incorporate a lithium button cell battery At the end of the product s life this battery should be removed for recycling purposes The battery is located on the motherboard or single board computer which can be easily accessed by removing the case top cover or side panel The battery ca
33. t is not overloaded The total power taken by all the electrical devices must not exceed the maximum outlet rating The total maximum rating can be ascertained by the cumulative maximum ratings of all the electrical devices running from the outlet If the rating of any device is in doubt please contact the respective manufacturer Care must be taken to ensure that all devices requiring a protective earth have a reliable earth connection especially when the power is distributed by means of a power strip It is recommended that after assembly and prior to the application of power an earth bonding test should be carried out Earth requirements may vary depending upon your location refer to any relevant local electric codes that provide data such as the size and types of conductors colour codes and connections necessary for safe grounding of electrical components Account for the unit s depth when choosing the depth of the enclosure Consider accessibility locations of accessories such as AC power outlets for installation and maintenance convenience Consideration must be given to overall mechanical stability Please ensure adherence to the user instructions of your chosen enclosure or rack The use of an anti tilt mechanism is recommended when mounting systems with sliding rails Typical weights of our Ventrix and Impact systems are Ventrix Impact 1xxx 1U gt 8kg Ventrix Impact 2xxx 2U gt 20kg Ventrix Impact 3xxx 3U
34. ur Black custom colours available for large orders Dimensions 485 W x 176 8 H x 480 D mm 19 1 x 7 0 x 18 9 Packaging size 541 W x 280 H x 660 D mm 21 3 x 11 0 x 26 0 Total drive capacity 4 x 5 25 external 1 x 3 5 external 2 x 3 5 internal Cooling 1 x 120mm ball bearing fan Air filter removable washable Gross weight approximately 20kg 427 00 S SED Slo P LS I a e a e Soo R g 3 m Q o Oo D D D GS h S Of a WF UU i n n 00000000000000000100000 eft rs I i Rear outside view p dn H n IG D 9 D Ge e Q Sl z m m g Sl A t Ln m L el L g e ee n eo 7 O i o IC woo ag ji 7 GEESE 5 o nl Top view Right side view Fa T
35. uring you apply firm even pressure to the top edge of the card Once you have ensured that the connector is fully in the respective PCI ISA PCle WARNING HOT SURFACE DO NOT TOUCH Components located on the motherboard may exceed 70 C socket insert the bracket securing screw If applicable refit the card retaining clamp and adjust the arm of the clamp to apply firm pressure to the top of the newly inserted card Refit the chassis cover and secure in place with the retaining screws Rear Connections PS 2 Mouse amp PS 2 PS 2 Mouse amp PS 2 Keyboard f L S For software installation please refer to the instructions supplied with your plug in card Serial COM ports COM Serial COM ports VGA output VGA output ANJO Na lla He H lr iii 170 LERI orn i You must check that there is sufficient power available to meet the requirements of your new card Additional cards could decrease airflow within the chassis and result in raised internal case temperature Fitting ISA PCI and PCI express Internal view photographs CPU cooler CPU Card clamp Power supply Drive bay CPU cooler Card clamp Power supply PCI express x16 expansion slots Impact E 42 52 57 Accessories AC DC Adapter Model Number FSP120 AAB AC input 100 240VAC DC output 19V 6 32A max Packaged gross weight Approximately 6 8kg Cables Serial breakout cable PS
36. vary depending on specified configuration The intention of this user guide is to get you acquainted with your new system and provide general end user information for the whole system If you require more specific technical information please refer to the component manuals that are included with your system Unpacking the system Your system has been supplied in a custom designed heavy duty cardboard box It is recommended that you retain all packaging material for future shipping purposes We take great care when shipping our systems but recommend that you take a moment to inspect your new system If you have concerns that the unit has sustained transit damage Contact our Support Department immediately If your system features a single board computer SBC it will come with internal transit packing foam Systems fitted with internal packing foam have an additional caution label across the power inlet The packing foam safeguards against internal damage during transit Before you start using your new system any internal packing foam must be removed Anti static precautions must be observed whilst removing the transit packing foam Removing transit packing foam Locate and remove the screws securing the chassis top cover Slide the top cover back and then lift it clear of the chassis Carefully remove the pink packing foam taking care not to disturb the internals of your system ensuring cables are not snagged whilst removing the f

Download Pdf Manuals

image

Related Search

Related Contents

Rapport spécial, Avril 2015 : L`entretien des routes en hiver  N。uveーーe c。ーーecti。n aut。mne et hiver 20ー2・20ー3  Switch On Mikrowelle Bedienungsanleitung  duetto wrapping baler operator`s manual  ConnectPort™ Display User Manual  MET16 MEMORY EMULATOR TRACER Manual de instrucciones  allegato i riassunto delle caratteristiche del prodotto  MI Regulation TAC4 DG + MODBUS GB  Broyeur à glace/ IceCrusher  OBD Bluetooth Transmitter User`s Manual  