User Manual v1.0
Contents
1. XXXX_CALLALL ON where CALLALL enables mandatory calling feature for all users XXXX_SMSEXTRA 25 SC14 CC124 where SC14 means that alarm SMS message sending feature is disabled for users NO1 and NO4 after Z5 zone is triggered CC124 means that alarm calls are disabled for users NO1 NO2 and NO4 after Z5 zone is triggered USER MANUAL ELDES ESIM251 V1 0 17 A FOR ADVANCED USERS A All these features can be configured using program Esim251 ConfigTool E g 2 The user wants to connect Esim251 system to the programmable outputs PGM of an existing alarm system House territory is entered through electrically controlled gates There are 5 users in total NO1 is the housekeeper NO2 is a neighbour NO3 NO5 are family members Task NO1 Configuring the system so that house alarm activation is reported to the housekeeper NO1 by SMS message and a call as well as to the neighbour NO2 but by SMS message only Housekeeper NO1 Neighbour NO2 Family members ve NO3 NO4 NO5 As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS message it is necessary to enable mandatory SMS message delivery see more in chapter 3 7 and to remove the users who should not receive alarm messages Besides as per factory default settings calling feature in the case of alarm is also enabled for all users ther
2. MMMM means year mn month dd day va hour mi minutes E g XXXX_2009 01 01_14 15 USER MANUAL ELDES ESIM251 V1 0 9 3 Additional System Capabilities 3 1 Renaming alarm restore text and controller names Manufacturer initially set the following zone and controlled output names Zone1 Zone2 Zone3 Zone4 Zone5 OUTPUT1 E g if during the alarm Z1 zone was triggered the system sends SMS message with the text Zone1 Alarm text changes are made by sending the following SMS message XXXX_Z1 NewAlarmText Z2 NewAlarmText Z23 NewAlarmText Z4 NewAlarmText Z25 NewAlarmText E G XXXX_Z1 Intrusion though the door Z2 Fire sensor triggered Texts can be changed all at once for all zones several of them or one by one Maximum text for one zone is 24 characters The space is equal to one character Each new text must be followed by a semi colon As semi colon is used for separating texts for different zones it cannot be used in the middle of alarm texts t it can only be used at the end Texts cannot be the same as control commands detector triggered Triggered zone restore text If you want to be notified by an SMS message when the triggered zone is restored Restore mode must be turned on The mode is turned on by sending a particular SMS command Please refer to chapter 3 9 or configuration program Zone restore text is changed by sending the following SMS mesaage XXXX_ZR1 NewRestoreText ZR2 NewRest
3. calls is disabled for all users it is necessary to enable this feature and to set the users who will be able to control the output Besides it is also necessary to set relay status for every user when he she calls the sys tem In this case the relay must be activated and the activation duration must be 1 second after this the relay returns to the previous status Confirmation call feature must be enabled for user 5 and it is necessary to choose the length parameters for that call Also confirmation SMS messages have to be enabled for user NO3 a First of all Esim251 system relay output has to be connected to the connectors of gate control unit b The following configuration SMS message must be sent to Esim251 system XXXX_SMSEXTRA COC CE1345 CS5 CT513 SS3 MS10 MS30 MS40 MS50 MS1T0 0 1 MS3T0 0 1 MS4T0 0 1 MS5TO 0 1 where CE1345 means that C1 relay control via call is enabled for users NO1 NO3 NOS5 CS5 means that confirmation call feature is enabled for user NO5 after C1 relay status changes CT513 means that user NO5 will receive a confirmation call when the relay gets activated and call duration is 3 seconds 553 means that user NO3 will be informed about C1 relay status change by SMS message MS10 means that the relay is activated when user NO1 calls the system MS30 means that the relay is activated when user NO3 calls the system MS40 means that the relay is activated when user NO4 calls the system 550 means that th
4. control operations are run However when a special mode is enabled C1 output can be controlled by a call It can be controlled by all users NO1 NOS5 several users or only one of them By calling the system you can enable these 3 functions enable disable enable disable for a certain period or change output status with every call i e one call enables the status the next one disables it etc The parameters are changed by sending the following SMS message to the system Esim251 XXXX_SMSEXTRA COC Valuel Value2 ValueN user password Value structure is CnVal when Cn is command name 2 letters and Val its value Value CnVal table of values Cn command Val possible command meaning name 2 letters Command description Initial factory default values Comments control mode E g CE25 means that users NO2 and NO5 will be CE 1 2 3 4 5 is enabled for users blet iralth putyi f Enabling control No 1 2 3 4 5 able to control the output via call uigicel oe Via call modes CD 12382 E g CD25 means that output control via call is cD 1 2 3 4 5 is disabled for users Disabled for all disabled for users NO2 and NOS No 1 2 3 4 5 users NO1 NOS5 E g CS124 means that when users NO2 and Confirmation call x 7 i NO4 control the output via call they will be notified 1 2 34 5 mode is enabled for Enabling about a successful output
5. in the case of alarm is enabled for all users until the first successful delivery of the SMS message it is necessary to enable mandatory SMS message delivery see more in chapter 3 7 and to remove the users who should not receive alarm messages Besides as per factory default settings calling feature in the case of alarm is also enabled for all users therefore call function must be disabled for all users except users NO3 and NO4 As per factory default settings in the case of alarm the system rings until the first answered call therefore in this case nothing should be configured a First of all security central unit must be programmed in the way so that when security sensors of enterprise A are triggered the signal is transmitted to security central unit output PGM4 PGM4 is connected to Esim251 input Z4 The following configuration SMS messages must be sent to Esim251 system XXXX_SMSALL ON where SMSALL enables mandatory SMS message delivery feature for all users XXXX_SMSEXTRA Z4 SC125 CC125 Where SC125 means that alarm SMS message delivery feature is disabled for users NO1 NO2 and NO5 after Z4 zone is triggered CC125 means that alarm calls are disabled for users NO1 NO2 and NOS after Z4 zone is triggered 16 A FOR ADVANCED USERS A All these features can be configured using program Esim251 ConfigTool Task NO4 Configuring the system so that the intrusion to enterprise B premises is repo
6. in the event of alarm starts calling on the first number and if the first call is unsuccessful it immediately tries reaching subscriber No2 etc 2 3 1 Saving or Changing Numbers Send SMS message with the following text to Esim251 XXXX_NR1 37011111111_NR2 37011111111_NR3 37011111111_NR4 37011111111_ NR5 37011111111 Ones should be replaced with user numbers Numbers don t have to be entered in sequential order right away E g user can enter first and fourth number by sending the following SMS message XXXX_NR1 37011111111_NR4 37011111111 Or individually one number at a time XXXX_NR3 37011111111 Numbers can be changed same way as described above New number will overwrite old one the refore no erasing is necessary 2 3 2 Verification of Saved Numbers To inquire the system about pre programmed numbers send the following SMS message XXXX_HELPNR The system will reply with all pre programmed numbers 2 3 3 Deletion of Saved Numbers To erase NR2 NR35 send the following SMS message XXXX_NR2 DEL_NR3 DEL_NR4 DEL_NR5 DEL E g XXXX_NR3 DEL The system will not allow erasing first number NR1 It can only be modified 2 4 Date and Time Settings It is important to set correct date and time so that the system can send reports at specified times Date and time can be set by sending the following format SMS message XXXX_MMMM mn dd_va mi where
7. operator Central number can be entered by sending SMS message XXXX_SMS_ 37011111111 is a password Default password is four zeros 0000 SMS central number is provided by cellular network provider Example 0000_SMS_ 37069899992 Message should be sent to the number of SIM card which is placed into the system If all went correct the system will send a messa ge SMS central number has been successfully changed to 37011111111 2 2 Password Change All SMS commands start with a password please memorize it Manufacturer default password is our zeros 0000 which is necessary to change Manufacturer default password can be changed by sending the following SMS message to Esim251 0000 55 To replace your password send the following SMS message YYYY_PSW_XXXX is any four digit number except four zeros Non numerical characters like dots colons spaces are not allowed YYYY is the old system password If you forgot the password default manufacturer password can be restored see chapter 4 1 for more details EN 2 3 User Numbers The system Esim251 allows to pre program up to five different mobile numbers which will have access to and control the system NR1 is mandatory while others can be skipped All numbers must be entered starting with international country code e g national code for Lithuania is 370 UK 44 By default the system starts sending all messages and
8. the system to call all recorded users regardless of the fact whether the user answered or rejected the call was out of network coverage or was engaged To turn on this feature send the following SMS message XXXX_CALLALL ON ATTENTION When this feature is enabled it will not be possible to stop calling the next user in the sequence even if the call is answered To disable this function send the following SMS message XXXX_CALLALL OFF If you want to configure calling only to particular users or only for particular zones refer to chapter 3 9 or use configuration program 3 9 Configuration for advanced users All features described in chapter 3 9 of the user manual can be configured using program Esim251 ConfigTool But if there is no possibility of connecting the computer or if you want to change the settings remotely you can do this via SMS messages We use changinf these settings by SMS message only for advanced users USER MANUAL ELDES ESIM251 V1 0 13 A FOR ADVANCED USERS A All these features can be configured using program Esim251 ConfigTool E g 1 The user wants to connect Esim251 system to an existing alarm in a building where enterprise A and and enterprise B work Both enterprises use the same alarm system that has two zones The alarm system has 5 programmable outputs PGM Task NO1 Configuring the system so that the director of a particular enterprise is informed about security enabling depending
9. 1 means that the user is notified about relay enabling by a callback the duration of the call is set by parameter CT13 CT13 means that the system calls for 3 seconds CT06 means that when the relay turns off after 8 hours and 5 minutes the user is notified by a call again but call duration is 6 seconds SE1 means that the user is also notified about relay enabling by SMS message To see the preset values for any command send SMS message with the same format that you use when changing parameters only Value structure will have no value XXXX_SMSEXTRA OCTE Valuel Value2 see ValueN user password Value structure is Cn where Cn is command name 2 letters E g XXXX_SMSEXTRA OCTE CB CT SB USER MANUAL ELDES ESIM251 V1 0 31 4 Appendix 4 1 Restoring Default Parameters To restore default parameters disconnect power supply and USB connector short circuit connect connectors D1 and D2 connect power supply for 5 seconds disconnect power supply disconnect connectors D1 and D2 4 2 Esim251 ConfigTool configuration software To configure the system quicker and easier as well as use more system capabilities use configuration program Esim251 ConfigTo ol which can be downloaded from our website www eldes lt Before connecting USB cable to the computer read Esim251 ConfigTool user guide available in the program chapter HELP 4 3 Technical Support Indication Possib
10. 251 ConfigTool 3 9 1 Additional possibilities of configuring zones inputs alarm and restore Initial factory default settings During the alarm the system calls and sends SMS messages to all pre programmed users until the first successful SMS delivery or a call rejected by the user The users are not notified about zone restore Zone delay due to interference is 600ms i e only the impulse that is longer than 600ms is considered an event All zones Z1 Z5 are enabled Impulse counting mode is turned off To change these settings send the followinf SMS message XXXX_SMSEXTRA Zn Valuel Value2 ValueN XXXX user password Zn possible values 1 2 3 4 5 Define the number of the zone that is changed Value structure is CnVal where Cn means command name 2 letters and Val its value digits without spaces or punctuation marks Value CnVal Table of values Val possible Cn command Initial factory command Command description Comments name 2 letters i default values meaning During the alarm SMS 5512345 E g 5525 means that during alarm SMS 55 1 2 3 4 5 message will be sent to Enabled for all message sending is enabled for users NO2 users NO 1 2 3 4 5 users NO1 NOS5 and NO5 During the alarm SMS sc 12345 message sending to E g SC2 means that SMS message sending aaa users No 1 2 3 4 5 will be will be disabled for user NO2 Alarm gt fi ti disabled confi
11. 5 hours 10mins 3seconds F 3 for user NO1 you have to use the command Setting relay impulse 51 5 103 relay 1 2 3 4 5 and dieien tsas This means that when afore mentioned user NO1 impulse MS No 1 2 3 4 5 h hours 5 7 Th m s control the relay via call the impulse duration is d 5hours 10mins and 3seconds and after this period 5 the relay returns to the previous status Example of SMS message configuring C1 output XXXX_SMSEXTRA COC CE1234 CS123 MS10 MS42 MS1T0 0 40 This message configures C1 output parameters CE1234 means that C1 output can be controlled by users NO1 NO4 NO5 cannot control via call 5123 means that only users NO1 NO2 and NO3 will receive confirmation call MS10 means that when user NO1 calls the system he she enables C1 input but cannot disable it via call The user can disable it via SMS message if he she knows the password MS42 means that when user NO4 calls the system he she will either enable or disable output C1 TOGGLE mode is on It depends on the relay status before making a call MS1T0 0 40 means that when user NO1 call the relay is turned on for 40seconds and then it automatically turns off To see the preset values for any command send SMS message with the same format that you use when changing parameters only Value structure will have no value This does not apply to MS and CT commands When requesting MS and CT parameters MS and CT must be f
12. T Gi Worker NO1 NO2 SA Gas boiler Automatic Worker system NO3 As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS message it is necessary to remove users NO2 and NO3 and disable alarm calls for all users It is also necessary to invert Esim251 input from NO to NC mode so that alarm is given only when the signal disappears a First of all a signal indicating gas boiler breakdown isconnected to Esim251 input Z1 b The following configuration SMS message must be sent to Esim251 system XXXX_SMSEXTRA Z21 SC23 CC123 LI1 where SC23 means that alarm SMS message sending is disabled for users NO2 NO3 after Z1 zone is activated 6123 means that alarm calls are disabled for users NO1 NO2 and NO3 after Z1 zone is activated We make an assumption that users NO4 NO5 were not entered to the system at all LI1 means that NC normally closed mode is enabled for the input 22 A FOR ADVANCED USERS A All these features can be configured using program Esim251 ConfigTool Task No2 Configuring the system so that the operating personnel member 2 receives SMS message if the pump was triggered for 10 times Worker Gas boiler NO1 Worker NO2 Moi system NO3 As per factory default settings SMS message sending feature in
13. User Manual v1 0 Safety Please r Copyright instructions ead and follow these safety guidelines and assembly instructions in order to maintain safety of operators and people around Alarm and control device Esim251 further referenced as the system contains an integrated radio transceiver operating in GSM 850 900 1800 1900 MHz bands Don t use the system where it can interfere with other devices and cause any potential danger Don t mount the system next to medical equipment or devices if they require so Don t use the system in hazardous environment Don t expose the system to high humidity chemical environment or mechanical impacts Don t attempt to personally repair the system System label is on the bottom side of the device System Esim251 is a device mounted in limited access areas Any system repairs must be done only by qualified safety aware personnel Mains power must be disconnected before any installation or tuning work starts The system installation or maintenance must not be done during stormy conditions The system must be powered by main 10 24V 50Hz 200mA AC or 10 24V 200mA DC power supply which must be approved by LST EN 60950 1 standard and be easily accessible Any additional devices linked to the system Esim251 computer sensors relays etc must be approved by LST EN 60950 1 standard External power supply can be connected to AC mains only inside instal lation room with autom
14. atic 2 pole circuit breaker capable of disconnec Phase ting circuit in the event of short circuit or over current condition Open oe circuit breaker must have a gap between connections of more than 3mm AC 230V 50Hz DC24V USB cable Fuse F1 type C1S 2 5A Blown fuse cannot be replaced by the user and the replacement fuses have to be exactly the same as indicated by the manufacturer The device is fully turned off by disconnecting 2 pole switch off device of the external power supply or any other linked device that the system Esim251 is powered from If you use security class computer for setting the parameters it must be connected to earth The WEEE Waste Electrical and Electronic Equipment marking on this product or its documentation indicates that in the EU the product must not be disposed of together with household waste ELDES UAB 2009 All rights reserved It is strictly forbidden to copy and distribute information in this document or pass to a third party without an advanced written authorization from ELDES UAB ELDES UAB reserves the right to update or modify this document and or related products without a warning Hereby ELDES UAB declares that this GSM ALARM AND CONTROL SYSTEM Esim251 is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity may be consulted at www eldes lt ce Limited Liability The buyer must a
15. confirmation call feature and set the length parameters for that call To differentiate whether the relay was enabled confirmation call will be set to ring for 3 seconds and the confirmation call will ring for 10 seconds when the relay is disabled a First of all Esim251 system relay output C1 has to be connected to the connectors of heating system control unit b The following configuration SMS message must be sent to Esim251 system XXXX_SMSEXTRA COC CE1 CS1 CT113 CT1010 MS12 where CE1 means that C1 relay control via call is enabled for users NO1 CS1 means that confirmation call feature is enabled for user NO1 after C1 relay status changes CT113 means that user NO1 will receive a confirmation call when the relay gets activated and call duration is 3 seconds CT1010 means that user NO1 will receive a confirmation call when the relay is deactivated and call duration is 10 seconds MS12 means that Toggle mode is activated for user NO1 which means that relay status is changed with every call 20 A FOR ADVANCED USERS A All these features can be configured using program Esim251 ConfigTool Task No2 Configuring the system so that users NO1 and NO2 receive SMS message about a burst water pipe flood at home SMS mes sages must be delivered to both users p Flood detector User NO1 6 Heating Controller User NO2 e Eee A
16. e relay is activated when user NO5 calls the system MS1T0 0 1 means that relay status is changed for 1 second when user NO1 calls the system MS3T0 0 1 means that relay status is changed for 1 second when user NO3 calls the system MS4T0 0 1 means that relay status is changed for 1 second when user NO4 calls the system MS5T0 0 1 means that relay status is changed for 1 second when user NOS calls the system USER MANUAL ELDES ESIM251 V1 0 19 A FOR ADVANCED USERS A All these features can be configured using program Esim251 ConfigTool E g 3 The user wants to connect Esim251 system to the heating system of the house Task No1 Configuring the system so that house heating system is turned on and turned off by the user NO1 via free call This user should also receive free information abut successful turning on or turning off of the heating system Confirmation Call 3sek 10sek ere eee User g NO1 Heating Controller User A 2 As per factory default settings C1 output control via calls is disabled for all users it is necessary to enable this feature and to set the users who will be able to control the output in this case it is user NO1 Besides it is also necessary to set relay status for user NO1 when he she calls the system In this case you must set the system so that the relay is activated after one call and deactivated after another one Toggle and so on User NO1 needs to enable
17. eaning h m Indicates the time for E g WT18 10 means event start time It can be Setting enabling WT enabling or disabling enabling and disabling It depends on the set disabling time h hour m C1 output in hours ST value A period PT must also be indicated minutes and minutes otherwise relay status will not change See below ST1 i 1 ae E g ST1 means that when the set time comes the sunos ay y Relay is relay is enabled by WT command status whether enabled it is enabled or ST disabled 3 0 Ralaviedicabled E g STO means that when the set time comes the y relay is disabled by WT command A h m Indicates the time in E g PT1 20 means that after automatic enabling Setting the period x AP hours and minutes for disabling which is indicated in WT command relay of enabling PT 3 i Bate h hour m which 1 relay status status is changed to opposite for 1 hour and 20 disabling A 2 A minutes is changed minutes A CS1 means that the preset user is informed about Users are notified x z Re the period start of C1 output enabling or disabling 1 about period start by 4 k A via short call The user is set by using UC command a confirmation call Setting See below confirmation call cs for period start Users are not notified co r CSO means that nobody is informed about period 0 about period start by Call is not start by a call a confirmation call made p CE1 means that the preset user is info
18. efore call function must be disabled for users NO2 NO5 and left enabled for NO1 only a First of all security central unit must be programmed in the way so that when security sensors are triggered the signal must be transmitted to security central unit output PGM b PGM is connected to Esim251 input Z1 c The following two configuration SMS messages must be sent to Esim251 system XXXX_SMSALL ON where SMSALL enables mandatory SMS message delivery for all users XXXX_SMSEXTRA Z1 SC345 CC2345 Where 56345 means that alar SMS message sending is disabled for users NO3 NO4 and NO5 after Z1 zone is triggered 2345 means that alarm calls are disabled for all users exept NO1 after Z1 zone is triggered 18 A FOR ADVANCED USERS A All these features can be configured using program Esim251 ConfigTool Task NO2 Configuring the system so that house gates could be opened via free calls by the housekeeper NO1 and his family members NO3 NO4 and NO5 After every successful gate opening the user NO5 wants to receive a confirmation call CALLBACK the duration of which is 3 seconds and the user NO3 wants to receive a confirmation SMS message a eee Control Ee Geen Call Pepe Confirmation Fee mee Family member A SMS NO3 Housekeeper NO1 Y Family member NO4 Confirmation Call Family member 5 As per factory default settings C1 output control via
19. firmations UC 1 2 3 4 5 notified about period delivered to user No2 about period start end Only one user can be selected start end k SS1 means that the preset user is notified about Users are notified i i Serie 1 about period start by period start of enabling disabling C1 output Setting SMS Message by SMS message The user is set by using UC confirmation ss 3 command See below SMS message for had period start users are not nonne SSO means that nobody is informed about period 0 about period start by sso start by SMS message SMS message Users Sa nonne SE1 means that the user is also notified about relay Setting 1 about period end by disabling by SMS message confirmation SE SMS message SMS message for Users are not notified Ath j period end 0 abolttperiod end by SEO SEO means that nobody is informed about period end by SMS message SMS message Example of SMS message configuring C1 output ways of information by preset schedule XXXX_SMSEXTRA OCTE WT20 15 ST1 PT8 0 UC2 CS1 CT13 CT06 SE1 This message configures C1 output parameters using a schedule WT20 15 means that relay enablig time is set for 20 15 every day ST1 means the user set the relay to turn on on that time PT8 5 means that the relay is enabled and is on for 8 hours and 5 minutes and after that it turns off and turns on again at 20 15 the following day etc UC2 means that information about enabling disabling is sent to user s No2 telephone CS
20. gree that the system will reduce CONTE NT the risk of fire theft burglary or other dangers but does not guarantee against such events ELDES UAB will not take any responsibility regar 1 ding personal property or revenue loss while using the system ELDES UAB responsibility according to local laws does not exceed value of the purchased system ELDES UAB is not affiliated with GSM operators providing cellular services therefore is not respon sible for the quality of cellular services Manufacturer Warranty The system carries a 24 month warranty by the ma nufacturer ELDES UAB Warranty period starts from the day the system has been purchased by the end user The warranty is valid only if the system has been used as intended following all guidelines listed in the manual and within specified operating conditions Receipt with 3 purchase date must be kept as a proof The warranty is voided if the system has been exposed to mechanical impacts chemicals high humidity fluids corrosive and hazardous environ ment or other force majeure factors Package Content The system Esim251 Esim251 user manual GSM 8 Fastening 5 About User Manual This document describes remote alarm system Esim251 its operation and installation It is very important to read User Manual before start using the system A q
21. guration g During the alarm the CS12345 Enabled cs 1 2 3 4 5 system will call users for all users E g 5124 means that during alarm calls are No 1 2 3 4 5 NO1 NOS enabled for users NO1 NO2 and NO4 During the alarm calling n cc 12345 users No 1 2 3 4 5 will be E g CC12345 means that during the alarm A none of the users will be called disabled During input restore Sms E g SE1 means that during zone reset SMS aE 12342 Ese message delivery is enabled for user No1 users No 1 2 3 4 5 g y During input restore Dte E g SD45 means that during zone restore A SD 1 2 3 4 5 SMS message sending is EAE SMS message sending is disabled for users disabled for No 1 2 3 4 5 NO4 and NOS configuration users NO1 NOS CE 12345 During input restore users E g CE12 means that during input restore mace No 1 2 3 4 5 will be called calls are enabled for users NO1 and NO2 During input restore CD12345 E g CD1345 means that when the input is CD 1 2 3 4 5 calling users No 1 2 3 4 5 Disabled for all restored users NO1 NO3 NO4 and NO5 will is disabled users 5 not be called Possibility to change input type i e to Setting input type invert E LIO S 0 NO normally open LIO Normally open It means that the input is considered inactivated if there is no signal Input levels LI Possibility to change input type i e to Setting input type invert 1 1 NC normall E g 11 means that input is in normal status y when the signal is tra
22. have all values equal zeros Zeros it is not allowed to have all values equal E g to switch the pump on for minutes and 23 seconds send SMS XXXX_PUMP ON 00 01 23 If the pump was enabled before and user want to disable it for 01 minute and 23 seconds send SMS XXXX_PUMP OFF 00 01 23 If you want to use more C1 Output capabilities as TOGGLE automatic enabling and disabling for a par ticular hour or control use configuration program Esim251 ConfigTool or see chapter 3 9 2 3 7 SMS Message Delivery to Multiple Users Upon activated alarm in security system Esim251 SMS messages are repeatedly sent until first successful delivery to one of the users The system starts with NR1 and if delivery fails it follows with NR2 etc It is also possible to set the system so that it sends SMS message to all recorded users EN To enable this function send the following SMS message XXXX_SMSALL ON To disable this function send the following SMS message XXXX_SMSALL OFF If you want to configure SMS message delivery only for particular users or only for particular zones refer to chapter 3 9 or use con figuration program 3 8 Calling all users During the alarm Esim251 system starts calling NR1 If the call to NR1 was unsuccessful or the subscriber was out of network co verage the call is forwarded to NR2 etc If the user rejected the call or answered te call during the alarm the system stops calling However you can set
23. ignal strength satisfactory 1 Z2 0K ALARM 3 Z4 OK ALARM Z5 0K ALARM where OK means that the alarm in zone did not go off ALARM if it went off By default this status SMS message will be sent daily at 11 00 in the morning These parameters can be configured by sending the following SMS message XXXX_INFO PP VV PP message period in days valid values 00 10 VV time when message is sent valid values 00 23 E g XXXX_INFO 01 10 means that status message will be sent every 1 day at 10 00 If PP value is 0 and VV in the range of 1 23 then periodic status messages will be sent multiple times per day with period being specified as VV time E g XXXX_INFO 0 2 means that status message will be sent every 2 hours To disable periodic status messages send the following SMS message XXXX_INFO 00 00 The status messages will not be sent until enabling or restoring default parameters or receiving previously described XXXX_ INFO PP VV SMS message 3 4 Blocking Unknown Numbers By default Esim251 system can be controlled from any of the pre programmed numbers NR1 NR5 However the user can access the system and control parameters and outputs from any number as long as password is known To enable this feature send the following SMS message XXXX_STR ON To disable this feature send the following SMS message XXXX_STR OFF USER MANUAL ELDES ESIM251 V1 0 11 3 5 Remo
24. igures Z1 input parameters 5615 means that during the alarm SMS message sending is disabled for users NO1 and NOS As per manufacturer default settings SMS sending is preset for all users therefore users NO2 NO3 and NO4 SMS messages will still be delivered CC25 means that during the alarm calling function is disabled for users NO2 and NOS As per manufacturer default settings calling function is preset for all users therefore users NO1 NO3 and NO4 will still be called SE1234 means that SMS restore message sending is enabled for users NO1 NO2 NO3 and NO4 This means that when Z1 is restored after previous trigger these users will be informed about this restore by SMS message However alarms and restore SMS messages will be sent until the first successful delivery To enable compulsory message delivery to all users you should use the command XXXX_SMSALL ON as described in chapter 3 7 CE4 means that during Z1 restore only user NO4 is called LE1 means that input type for zone Z1 will be inverted i e the previous NO is changed to NC normally closed This means that the alarm is triggered only when the signal disappears and the restore is announced only in the case when the signal appears DV900 means that Z1 input is triggered only if the signal is suspended at least for 900ms Please note that input type was inverted to NC If inversion was not possible this DV900 command would mean that the signal transmitted must not be shorter tha
25. in security application assuring fast and reliable SMS message delivery and phone call connection USEFUL INFORMATION When choosing GSM cellular provider it is worth inquiring whether the service is used in security application assuring fast and reliable SMS message delivery and phone call connection System Esim251 and security unit COM must be connected Inputs Z1 Z3 Z4 Z5 are connected to security unit PGM outputs if PGM are implemented as open collector circuit or any other circuit and if it commutates with COM It is also possible to connect Z1 Z3 Z4 Z5 inputs to for instance motion sensor or any other sensor as well as automatics device provided the inputs are commutated with COM Input Z2 is commutated with a high level impulse Impulse duration is gt 600ms GSM communication and Metal box control system ESIM251 Saas PE contact AC DC RELAY COM 25 24 Z3 72 62 69 6 63 69 63 88 Fuse 500 mA 10 24V 230V 50Hz O Picture3 AC power supply connection circuit 8 38 9 amp js 8 HIGH LEVEL HV gt Alarm system or other appliance Picture 2 EN 1 6 System Installation The system can be installed only in a metal or non flammable plastic enclosure If the metal enclosure and transformer is used it is necessary to ground the enclosure using yellow green co
26. le reason Indicator is off or not blinking external power supply circuit not properly connected blown fuse no network signal Indicator blinking several times per SIM card is not inserted second code hasn t been disabled Sim card not active System does not send any SMS SIM card account depleted messages and or does not ring incorrect SIM central number no network signal user number is not programmed or disabled access from unknown numbers Received SMS message Incorrect incorrect syntax Format extra space symbol left in SMS message No sound while listening to remote microphone not connected microphone microphone connection incorrect While listening to remote micropho Change the position of the microphone or its lead in ne outside noise heard respect of system panel If your problem could not be fixed by the self guide above please contact your distributor or manufacturer tech support by email support eldes It More up to date information about your device and other products can be found at the manufacturer s website www eldes It 32 USER MANUAL ELDES ESIM251 V1 0 33 EN
27. leave any space at the beginning and the end of the message To set Esim251 system parameters easier and quicker you can use the computer USB cable and configuration program Esim251 ConfigTool You can read more in chapter 3 2 2 1 Selecting device language and verification of SMS central number The language in which the device communicates with the user can be chosen before changing factory default password To change the language in the system that is already configured reset default settings as described in 3 1 appendix Send SMS message with the required language code to the number of the SIM card inserted in Table of Language Code Esim251 possible P languages ithuanian E g if you want to set the English language send the following SMS message EN english EN 4 30 60 seconds later you should get an SMS message russian RU i 3 English language confirmed Go to chapter 2 2 upon reception of this message Otherwise check for network connection and call Esim251 system from your mobile and wait until the system drops the call You should get an SMS message asking to change default password Ot herwise check for network connection and change SMS central number SMS central number is saved in SIM card therefore if SIM card has been used to send SMS messages with a mobile phone then you don t need to change SMS central number Often SMS central number is already saved in SIM card by cellular
28. lour cable For the connection of 230V transformer use 3x0 75 mm2 1 thread double isolated cable The primary circuit of the transformer must be connected through 0 5A fuse 230V power supply cables cannot be grouped with low voltage cable group For the connection of power supply and output connectors use 1 thread 2x0 75 mm2 cable For the connection of input output connectors use 0 50 mm2 1 thread cable 1 Fasten the system in the box using fastening holders 2 Place SIM card in the holder but make sure that SIM card PIN code is disabled PIN code can be disabled by putting SIM card into mobile phone and following proper menus SIM card should not have any remaining SMS messages 3 Connect the circuit as shown in fig No 2 Power supply cables are connected last When connecting Esim251 to security central system power supply usually the security system AUX output is used 4 When AC power supply ground transformator is used connect according to circuit no 3 In this case you do not need to connect any other power supplies 5 The system will start in less than a minute LED2 indicator should be blinking or be ON indicating connection to GSM USER MANUAL ELDES ESIM251 V1 0 7 2 System Pre operation and the Main Control Commands VERY IMPORTANT Underscore symbol _ in this manual is used to represent space When writing SMS messages every underscore symbol should be replaced by single space symbol XXXX means password Don t
29. n 900ms 2 Example of SMS message configuring Z2 input 2 10555 This message configures Z2 input parameters means that impulse counting mode is enabled for Z2 input 555 means that the users will receive the alarm when 555 impulses are transmitted to the input Immediately after the alarm the counter resets and starts counting impulses until their number reaches 555 To see the preset values for any command send SMS message with the same format that you use when changing parameters only Value structure will have no value XXXX_SMSEXTRA Zn Valuel Value2 ValueN user password Zn possible values Z1 Z2 Z3 Z4 Z5 Define the number of the zone being changed Value structure is Cn where Cn is command name 2 letters E g XXXX_SMSEXTRA Z2 SS SC CC SE SD 26 FOR ADVANCED USERS All these features can be configured using program Esim251 ConfigTool 3 9 2 Additional possibilities of controlling and configuring controller C1 relay output Normally C1 output can be controlled only by SMS message as described in chapter 3 6 i e by enabling disabling it for a perma nent status or for a preset period However you can configure automatic enabling and disabling for a particular hour or control this function by a call 3 9 2 1 Settings of an output controlled by calls When calling on the number of system Esim251 the call is rejected and no
30. nforming about a users NO1 NOS5 successful output status change The first digit is a command the last digit All users receive refers to call time in seconds E g CT12 ase confirmation call when 2 means that if confirmation call mode is the output is enabled enabled the call will be forwarded to the s call time in seconds user who is trying to turn on the relay A The system will call for 2 seconds Confirmation call cT guration The first digit is a command the last digit All users receive refers to call time in seconds E g CT08 confirmation call when ctos means that if confirmation call mode is v the output is disabled enabled the call will be forwarded to the s call time in seconds user who is trying to turn off the relay The system will call for 8 seconds SBI SB1 means that when all users control Confirmation SMS the output via SMS message they will Ebina ea disabling i users NO1 NOS5 ge by message confirmation SMS message SMS confirm Confirmation SMS SBO means that when all users control the output via SMS message they will not SB 0 mode is disbled for all be informed about a successful output 1 status change by SMS message Example of SMS message configuring C1 output ways of information XXXX_SMSEXTRA 0CS CB1 CT13 CT06 581 This message configures C1 output parameters when controlled via SMS messages CB1 means that when the user enables disables out
31. nsmitted The event appears only when the signal disappears Impulse counting mode A y E IEO disabled Pvz IEO means impulse counting mode is disabled impulcecountina mode Input counts impulses The number of 1 9 impulses is defined by the command IC is enabled E o lE1 Impulse counting 2 The alarm is activated when a preset number of impulses is transmitted to the The number of impulses is input E g IC100 c determined In this case the alarm is activated when 100 impulses are sent to the input Maximum frequency is 5 The input is triggered only if the impulse Input protection Setting minimal input transmitted is not shorter than the preset against DV 100 10000 impulse duration It is DV600 value E g DV1000 means that the signal interference measured in milliseconds transmitted to the input is shorter than 1000ms 1s the alarm is not triggered USER MANUAL ELDES ESIM251 V1 0 25 A FOR ADVANCED USERS A All these features can be configured using program Esim251 ConfigTool ATTENTION Value fields are separated by commas Maximum SMS length is 160 characters Only one zone parameters can be configured by one SMS message Examples of using SMSEXTRA command Suppose in all cases initial parameters were not changed and are manufacturer default 1 Example of SMS message configuring Z1 input XXXX_SMSEXTRA 21 SC15 CC25 SE1234 CE4 LE1 DV900 This message conf
32. ntrolled by SMS 6553465 28 3 9 2 3 Output control settings by event time 30 Appendix 4 1 Restoring Default Parameters ssssssssscsssseessssccesnsnnseeeeseeeensneeees 32 4 2 Esim251 ConfigTool configuration software 4 2 Technical Support 1 General Information 1 1 Function Esim251 is a microcontroller based device used to inform users about the alarm in automatic or security systems and control one electric appliance relay 1 2 Operation Description Description of factory default settings Alarm and control system Esim251 works over GSM network It works 24 7 i e it always reacts to the incoming signal When the alarm siren motion sensor fire alarm sensor door sensor any other sensor or PGM output gets activated Esim251 sys tem sends an SMS message and calls to the preset numbers until one of the five possible users answers the phone or rejects the call or until the call will be ended by the mobile service provider After hanging up the phone the system turns back to the previous status An SMS message with the name of the activated input zone is being sent until its successful delivery to one of the users or until it is delivered to all users If you answer the call the microphone gets activated for listening After hanging up the phone the systems turs back to the previous status of active security Esim251 can control 1 elect
33. ollowed by one character user number 1 2 3 4 or 5 XXXX_SMSEXTRA COC Valuel Value2 ValueN XXXX user password Value structure is Cn where Cn is command name 2 letters E g XXXX_SMSEXTRA COC CE CS MS1 MS3 3 9 2 2 Settings of the output controlled by SMS messages This chapter describes the ways of informing users when they are trying to enable disable the relay via SMS messages described in chapter 3 6 Parameters are changed by sending the following SMS message to system Esim251 XXXX_SMSEXTRA 0CS Value1 Value2 ValueN XXXX user password Value structure is CnVal where Cn is command name 2 letters and Val its value digits without spaces or punctuation marks 28 All these features can be configured using program Esim251 ConfigTool Value CnVal table of values A FOR ADVANCED USERS A Val possible aia Cn command ee Initial factory command Command description Comments name 2 letters 2 default values meaning CB1 means that when users control the cB 1 Confirmation call mode output via SMS message they are notified is enabled for all users about a successful output status change Enabling Seren by a confirmation call disabling confirmation call CBO CBO means that when users control CallBack R R cB 0 Confirmation call mode the output via SMS message they will is disabled for all users Disabled for all not receive a call i
34. on which enter prise employee enabled the security system The director of enterprise A NO1 wants to receive an SMS message only and does not want to receive any calls the director of enterprise B NO2 wants to receive a call and does not want to receive any SMS messages Director A NO1 Enterprise A Enterprise B Director B NO2 Worker A NO4 Worker B NO5 Janitor NO3 As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS message it is necessary to remove the users that should not receive any alarm messages Besides as per factory default settings calling feature in the case of alarm is also enabled for all users therefore call function must be disabled for all users except user NO2 a First of all security central unit must be programmed in the way so that when security is enabled in office A PGM1 is triggered and when security is enabled in office B PGM2 is triggered b PGM1 is connected to Esim251 input Z1 and PGM2 is connected to Esim251 input Z2 PGM2 should be High level c The following two configuration SMS messages must be sent to Esim251 system XXXX_SMSEXTRA Z1 SC2345 CC12345 where 562345 means that alarm SMS message sending to users NO2 NOS is disabled after Z1 zone is triggered CC12345 means that alarm calls are disabled for all users NO1 NOS5 after Z1 zone i
35. oreText ZR3 NewRestoreText ZR4 NewRestoreT ext ZR5 NewRestoreText Controller name can be changed by sending the following SMS message XXXX_C1 NewControllerName Controller name cannot be followed by a semi colon You cannot change zone names and controller names at the same time E g XXXX_C1 PUMP 3 2 Enabling Disabling Zones NOTE Manufacturer set all the zones activated i e in mode ON USEFUL INFORMATION The zones can be enabled disabled together or separately one by one Enabling Zone Any zone can be enabled by sending the following SMS message 1 2 3 4 5 10 EN Disabling Zone Any zone can be disabled by sending the following SMS message 21 2 3 4 5 E g XXXX_Z2 ON or XXXX_WINDOWS ON or 2 or XXXX_WINDOWS OFF 3 3 Info on Status SMS The system Esim251 can any time be inquired about signal strength and the status of zones active at the time when SMS message is sent At the same time system test is performed If the answer to the request has been received it means the system finely operates It is also useful for those using prepayment service you can check if the credit in the account is sufficient for sending an SMS message Send the following SMS message XXXX_INFO The reply SMS will have following info e g 2008 08 07 11 15 S
36. put C1 he she receives ashort confirmation call CALLBACK CT13 means that when the relay is enabled confirmation call duration is 3 seconds CT06 means that when the relay is disabled confirmation call duration is 6 seconds SB1 means that confirmation message is sent informaing about enabling disabling To see the preset values for any command send SMS message with the same format that you use when changing parameters only Value structure will have no value XXXX_SMSEXTRA OCS Valuel Value2 ValueNn user password Value structure is CnVal when Cn is command name 2 letters E g XXXX_SMSEXTRA OCS CB CT SB USER MANUAL ELDES ESIM251 V1 0 29 3 9 2 3 Output ontrol settings by event time FOR ADVANCED USERS All these features can be configured using program Esim251 ConfigTool This chapter describes a possibility to control C1 output relay using timetable schedule It can be for instance atomatic turning on every day at 18 00 and turning off after 5 hours The parameters are changed by sending the following SMS message to the system Esim251 XXXX_SMSEXTRA OCTE Valuel Value2 ValueN user password Value structure is CnVal when Cn is command name 2 letters and Val its value Value CnVal table of values Cn command Valle possible Command Initial factory name 2 ea Comments command description default values letters x m
37. rmed about Users are notified A 3 the period end of C1 output enabling or disabling 1 about period end by a i i 8 via short call The user is set by using UC command confirmation call Setting See below confirmation call CE for period end PARRA CEO Pres neue CEO means that nobody is informed about period 0 about period end by a A Call is not end by a call confirmation call made The first digit is a command the last digit refers The user receives N A to call time in seconds E g CT12 means that if a confirmation call x Confirmation call N confirmation call mode is enabled whether for is when the output is CT12 2 duration period start ot end the call will be forwarded to enabled 4 es the user when relay is enabled The system will call s call time in seconds for 2 seconds 30 FOR ADVANCED USERS All these features can be configured using program Esim251 ConfigTool A The first digit is a commandi the last digit refers to The user receives call time in seconds 0 5 when the output is ctos 9 CT08 means that if confirmation call mode i is enabled whether for period start ot end the disabled x A C tine in geconds call will be forwarded to the user when relay is disabled The system will call for 8 seconds Setting the user who receives Sets which user is E g UC2 means that all confirmations will be con
38. ronic appliance a relay sending a password and a special command from a GSM phone of any of the users You can for example turn on the heating lighting lift the gates blinds etc The system will ignore requests coming from unknown telephone number or SMS message with wrong password List of other configurable system possibilities Normally open NO Operation only when the signal is transmitted Input types Normally closed NC Operation only when the signal is switched Event when the input is SMS is delivered when the signal is transmitted to the input Event when the input is restored SMS is delivered when the previously transmitted signal in the Ways of activating an event Restore EEES SMS is delivered if the number of te preset number of impulses in Mko eta the input is exceeded Max value is 4294967295 impulses SMS Only SMS or various call combinations can be chosen It is also possible to use only calls Any of the users can be assigned only SMS or only calls or call combinations Besides any of the users can be assigned a particular input zone or their combination E g a possibility to configure the system so that when input Z1 is Ways of transmitting an event activated SMS are sent only to users NR1 and NR5 and when Z2 Calls is activated SMS is sent to all users and the call would be for NR4 and so on When the functions SMSALL and CALLSALL are set SMS messages are sent to all use
39. rs and the call would be delivered regardless of the fact whether the call was answered rejected etc The relay can be turned on off by sending the command by SMS message You can turn on off Turning on off by SMS 1 for a permanent status 2 for a set period 3 for a set hour 4 repeating turning on off Ways of controlling output The relay can be turned on off by calling You can turn on off rela i relay Turning on off by a call 1 for a permanent status 2 for a set period 3 toggle relay status changes after each call The relay can be turned on for a set period at a set hour reset hour 9 the relay is turned on at 18 00 and it is on for 5 hours After 5 P hours it turns on automatically notifying the user about that A n When the computer is connected it is possible to see activations Event register Event register function p P network strength etc 1 3 Technical Specifications Electrical and mechanical specifications Supply voltage 0 24V 50Hz 200mA max 10 24V 200mA max Current used in standby mode 50mA max GSM modem frequency 850 900 1800 1900 MHz Number of low level negative inputs 4 Number of high level positive inputs Allowable low level negative input voltage values 0 1 6V Allowable high level positive input voltage values 5 50V Number of outputs Output type NO relay C1 output ma
40. rted to the janitor NO3 and enterprise B employee NO5 by SMS messages and calls and the director of enterprise B NO2 receives SMS message only Enterprise B employee NO5 must receive the phone call even in the case when the janitor NR3 answers the call Director A J NO1 Enterprise A Enterprise B Director B NO2 Worker A ca EB Nos SMs calls NO5 Janitor SMS Calls NO3 As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS message it is necessary to enable mandatory SMS message delivery see more in chapter 3 7 and to remove the users who should not receive alarm messages Besides as per factory default settings calling feature in the case of alarm is also enabled for all users therefore call function must be disabled for users NO1 NO2 and NO4 and left enabled for users NO3 and NO5 Also it is necessary to enable mandatory calling feature for all preset users see more in chapter 3 8 a First of all security central unit must be programmed in the way so that when security sensors are triggered the signal must be transmitted to security central unit output 5 b PGM is connected to Esim251 input Z5 The following three configuration SMS messages must be sent to Esim251 system XXXX_SMSALL ON where SMSALL enables mandatory SMS message delivery feature for all users
41. s per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS message and calling in the case of alarm is enabled for all users until the first answered call calling feature in the case of alarm must be disabled for users NO1 and NO2 Mandatory SMS delivery to all users must also be enabled a First of all a flood sensor is connected to Esim251 input 1 b The following configuration SMS messages must be sent to Esim251 system XXXX_SMSALL ON where SMSALL enables mandatory SMS message delivery feature for all users XXXX_SMSEXTRA Z1 CC12 where CC12 means that alarm call feature is disabled for users NO1 NO2 after Z1 zone activation We make an assumption that users NO3 NO5 were not entered to the system at all USER MANUAL ELDES ESIM251 V1 0 21 A FOR ADVANCED USERS A All these features can be configured using program Esim251 ConfigTool E g 4 The company taking care of automatic systems needs to have information about critical breakdowns of mechanisms and has to quickly react and eliminate the breakdown There are three members of operating personnel NO1 NO2 and NO3 Task No1 Configuring the system so that operating personnel member NO1 receives SMS message about the breakdown of gas boiler Working normally a gas boiler transfers a signal and when it breaks down the signal is not transmitted D
42. s triggered XXXX_SMSEXTRA 22 SC12345 CC1345 where 5612345 means that alarm SMS message sending is disabled for all users NO1 NOS5 after Z2 zone is triggered CC1345 means that all alarm calls are disabled for users NO1 NO3 NOS5 after Z2 zone is triggered 14 A FOR ADVANCED USERS A All these features can be configured using program Esim251 ConfigTool Task NO2 Configuring the system so that the janitor NO3 is informed about the triggered perimeter sensor of field territory by SMS messa ge and a call and when the sensor is reset the janitor receives SMS message only Director A NO1 Director B NO2 Worker A NO4 Worker B NO5 Alarm Restore Janitor SMS Calis sms NO3 As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS message it is necessary to remove the users that should not receive any alarm messages Besides as per factory default settings calling feature in the case of alarm is also enabled for all users therefore call function must be disabled for all users except user NO3 SMS message sending feature must also be enabled for user NO3 when input Z3 is restored a First of all security central unit must be programmed in the way so that when territory security perimeter sensor is triggered PGM3 is activated PGM3 is connected to Esim251 inp
43. ssage disabling users No 1 2 3 4 5 Before that the user has to turn on control from a SMS particular number by using CE command SMS confirm Confirmation SMS 5C12345 mens EC wian vece NON NOP aie cong k NO4 control the output via call the confirmation 1 2 3 4 5 mode is disabled for Disabled for all id SMS message informing about the successful users No 1 2 3 4 5 users NO1 NO5 output status change is not sent USER MANUAL ELDES ESIM251 V1 0 27 A FOR ADVANCED USERS A All these features can be configured using program Esim251 ConfigTool When users The first digit refer to user number The second 12345 and0 No 1 2 3 4 5 call the digit refers to command Therefore to seta output is enabled possibility for user NO1 to enable the relay via call i you have to use the command MS10 When Users The first digit refer to user number The second Type of control 1 2 3 4 5 and 1 No 1 2 3 4 5 call the 511 digit command Unetefore to peta ual MS disabled possibility for user NO1 to disable the relay via call i you have to use the command MS11 When users The first digits refer to user number The last digit No 1 23 455 call refers to command Therefore to set a possibility 1 2 3 4 5 and 2 ee Ml for user NO1 to enable the relay by one call and output status is P then disable it by the next call you have to se the changed TOGGLE command MS12 E g to set the timer for
44. status change by a users No 1 2 3 4 5 A disabling confirmation call confirmation call x CC12345 E g CC124 means that when users NO1 NO2 and Confirmation call z s CallBack PN NO4 control the output via call the call confirming cc 1 2 3 4 5 mode is disabled for Disabled for all about a successful output status change is disabled users NO1 NOS5 and users will not receive calls The first number refers to user number The second Confirmation call CT112 number is a command and the last number refers is made for users CT212 to call time in seconds 1 2 3 4 5 1 s No 1 2 3 4 5 when the 312 E g CT412 means that if confirmation call mode ouput is turned on CT412 is enabled user NO4 will receive a call if he she is i s call time in seconds CT512 trying to turn on the relay The system will call for onfirmation call duration 2 seconds a The first number refers to user number The second Confirmation call CT108 number is a command and the last number refers is made for users CT208 to call time in seconds 1 2 3 4 5 0 s No 1 2 3 4 5 when the CT308 E g CT408 means that if confirmation call mode output is turned off CT408 is enabled user NO4 will receive a call if he she is s call time in seconds CT508 trying to turn off the relay The system will call for 8 seconds E g 55124 means that when users NO1 NO2 and ea Enabling 55 1 2 3 4 5 mode is enabled for A eerie confirmation SMS me
45. te Microphone Listening NOTE To enable this feature it is necessary to connect microphone connector to MIC slot The microphone is additional equipment tha can be purchased in trading centers You can listen to what is going on in the secured premises by sending the following SMS message XXXX_MIC The system will ring the sender of the received SMS and upon answering the call the user can listen to any sounds in the building The phone call must be answered within 20 seconds otherwise the system will stop trying and return to previous state 3 6 Managing C1 Controller Timer Alarm system Esim251 contains a controller C1 a relay output It can be used to control various electrical devices such as electric pumps heating lighting etc When the controller is enabled RELAY connectors are connected The device is turned on by sending the following SMS message XXXX_C1 ON The device is turned off by sending the following SMS message XXXX_C1 OFF Instead of C1 it is also possible writing a real controller name E g XXXX_PUMP ON Timer Alarm system Esim251 has internal timer clock This feature allows any controlled output to be switched on or off for a specified time period The following SMS command should be sent XXXX_C1 ON OFF vv mm ss ON output enabled OFF disabled vv hours valid values 00 23 mm minutes valid values 00 59 ss seconds valid values 00 59 It is not allowed to
46. the case of alarm is enabled for all users until the first successful delivery of the SMS message it is necessary to remove users NO1 and NO3 and disable alarm calls for all users It is also necessary to enable impulse counting mode for Esim251 input Z3 and set the number of expected impulses a First of all a signal indicating PUMP triggering is connected to Esim251 input 3 b The following configuration SMS message must be sent to Esim251 system XXXX_SMSEXTRA 23 SC13 CC123 IEl IC10 where SC13 means that alarm SMS message sending is disabled for users NO1 NO3 after Z3 zone activation CC123 means that alarm calls are disabled for users NO1 NO2 and NO3 after Z3 zone activation We make an assumption that users NO4 NO5 were not entered to the system at all IE1 enables impulse counting mode for zone Z3 10 means that the alarm is given to Z3 input after 10 impulses are transmitted USER MANUAL ELDES ESIM251 V1 0 23 A FOR ADVANCED USERS A All these features can be configured using program Esim251 ConfigTool E g 4 The company taking care of automatic systems needs to have information about critical breakdowns of mechanisms and has to quickly react and eliminate the breakdown There are three members of operating personnel NO1 NO2 and NO3 Task No3 Configuring the system so that operating personnel members NO1 NO2 and NO3 can reboot the hanged automatic control system without going
47. to the object but via a short call to Esim251 system D Worker Gas boiler NO1 3 NO2 NO3 As per factory default settings C1 output control via calls is disabled for all users it is necessary to enable this feature and to set the users who will be able to control the output Besides it is also necessary to set relay status for every user when he she calls the system In this case the relay must be activated and the activation duration must be 2 seconds after this the relay returns to the previous status a First of all Esim251 system relay output has to be connected to the connectors of automatic control unit b The following configuration SMS message must be sent to Esim251 system XXXX_SMSEXTRA COC CE123 MS10 MS20 MS30 MS1T0 0 2 MS2T0 0 2 MS3T0 0 2 where CE123 means that C1 relay control via call is enabled for users NO1 NO3 MS10 means that the relay is activated when user NO1 calls the system MS20 means that the relay is activated when user NO2 calls the system MS30 means that the relay is activated when user NO3 calls the system MS1T0 0 2 means that relay status is changed for 2 seconds when user NO1 calls the system MS2T0 0 2 means that relay status is changed for 2 seconds when user NO2 calls the system MS3T0 0 2 means that relay status is changed for 2 seconds when user NO3 calls the system 24 FOR ADVANCED USERS All these features can be configured using program Esim
48. uick start guide is located in first two chapters Chapter 3 and 4 describe additional system capa bilities General Information 1 1 Function 1 2 Operation Description 1 3 Technical Specifications 1 4 Connector Functionality 1 5 Connection Circuit 1 6 System Installation System Pre operation and the Main Control Commands 2 1 Selecting device language and verification of SMS central number 2 2 Password Change 2 3 User Numbers 2 3 1 Saving or Changing Numbers 2 3 2 Verification of Saved Numbers 2 3 3 Deletion of Saved Numbers 2 4 Date and Time Settings 9 Additional System Capabilities 3 1 Renaming Zones and Controlled 10 3 2 Enabling Disabling Zones 3 3 Info on Status 5 5 3 4 Blocking Unknown Numbers 3 5 Remote Microphone Listening 3 6 Managing C1 and C2 Controlled Outputs Timer 3 7 SMS Message Delivery to Multiple Users 3 8 Calling 5 3 9 Configuration for advanced users 3 9 1 Additional possibilities of configuring zones inputs alarm and 25 3 9 2 Additional possibilities of controlling and configuring controller C1 relay output 3 9 2 1 Settings of the output controlled by calls 3 9 2 2 Settings of the output co
49. ut 3 c The following configuration SMS message must be sent to Esim251 system XXXX_SMSEXTRA 23 8C1245 CC1245 SE3 where 561245 means that alarm SMS message sending to users NO1 NO2 NO4 and NOS is disabled after 3 is triggered CC1245 means that alarm call feature is disabled for users NO1 NO2 NO4 and NOS after zone Z3 triggered SE3 means that SMS message sending feature is enabled for user NO3 after Z3 input is restored USER MANUAL ELDES ESIM251 V1 0 15 A FOR ADVANCED USERS A All these features can be configured using program Esim251 ConfigTool E g 1 The user wants to connect Esim251 system to an existing alarm in a building where enterprise A and and enterprise B work Both enterprises use the same alarm system that has two zones The alarm system has 5 programmable outputs PGM Task NO3 Configuring the system so that the intrusion to enterprise A premises is reported to the janitor NO3 and enterprise A employee NO4 by SMS messages and calls Enterprise A employee NO4 wants to receive a call only in the case if the janitor NO3 does not answer the call is out of network coverage or at that time the janitor s telephone line is engaged Director A NO1 Enterprise A Enterprise B Director B NO2 Worker A NO4 Worker B NO5 8 0 Janitor Alarm Janitor SM5 cails NO3 As per factory default settings SMS message sending feature
50. ximum commutating values A 24V DC 0 5 125 AC Dimensions 82x63x20mm Operating temperature range 20 550C 1 4 Connector Functionality LED1 LED2 DEFAULT D1 D2 Picture 1 30 550C with limitations Short explanation of the main units GSM MODEM GSM network 850 900 1800 1900 MHz modem SIM CARD SIM card LED Light emitting diodes indicator DEFAULT Connectors D1 and D2 for restoring default settings ANT GSM antenna SMA type connector USB Mini USB connector Connector functionality Labeling Explanation AC DC Power supply pins RELAY Dry relay contact Normally open NO RELAY Dry relay contact Normally open NO COM Common pin Z5 Low level input Z5 Z4 Llow level input Z4 73 Low level input Z3 Z2 High level input Z2 1 Low level input Z1 USER MANUAL ELDES ESIM251 V1 0 EN LED indicators functionality LED1 Indicates SIM card status LED2 status Meaning LED2 Indicates network status OFF No network connection Blinking 3 times per second Poor network connection LED status Meaning Blinking 1 time per second Medium network connection or SIM card is working properly ON Excellent network connection ON SIM card error 1 5 Connection Circuit USEFUL INFORMATION When choosing GSM cellular provider it is worth inquiring whether the service is used
Download Pdf Manuals
Related Search
Related Contents
Instrucciones de uso TORO 30 LevelOne Outdoor Housing (DC 12V) Descargar Manuels Océ CS9350 Eco Solvent - Oce Display Graphics Systems Inc. Qpets 4 in 1 Training Collar User Manual 700 B-Vent Clinical Education Untitled Internship Report A System Analysis in the Basis of Corporate Copyright © All rights reserved.