1. Daylight sensor The daylight threshold can be set on DIP switches to fit for particular application Disable 50Lux 10Lux 5 Lux O L_1h oe 23 0 100 II 75 Il 50 IV Sensor OFF s ll 30s IIl 3min IV lOmin Disable Il 50Lux Ill 1 OLux IV 5Lux Stand by period corridor function This is the time period you would like to keep at the low light output level a before it is completely switched off in the long absence of people ne R Note Os means on off control IV 00 means bilevel dimming control fixture never switches off when NOHO ese daylight sensor is disabled Stand by dimming level This is the dimmed low light output level you would like to have after the 10 hold time in the absence of people I 30 Technical Data Operating voltage Input current Input power Warm time Detection area Hold time Daylight threshold Stand by period Stand by dimming level Microwave frequency Microwave power Detection range Detection angle Mounting height Output LED current Output LED voltage Output LED power Empty load voltage Power factor Efficiency Operating temperature Abnormal protection EMC standard Safety standard Certification Dielectric strength IP rating 220 240VAC 50 60Hz 0 17 0 16A 35W Max 20s Sensor OFF 50 75 100 100 50 1
2. Cable back entry Functions and Options Daylight Monitoring Function Hytronik specially designed this function in software for deep energy saving purpose 1 With sufficient natural light the light won t turn on when motion detected 2 After hold time the light turns off completely if surrounding natural light is sufficient 3 When stand by period is preset at 00 the light will turn off completely when surrounding natural light is sufficient during stand by period and turn on at dimming level automatically when natural light is below daylight threshold With sufficient natural light the At dusk as the natural light The light switches on at 100 Light dims to stand by level atter light does not switch on even drops below threshold value when there is movement the holdime there is movement detected the sensor turns on the light at detected the dimmed level Settings on this demonstration goes in cycle Hold time 1Omin Daylight threshold 50lux during the night Stand by period 00 Stand by dimming level 10 100 on when movement At dawn light turns off Light does not switch on even detected and dims to 0 in completely when natural light when movement detected long absence reaches above daylight during the daytime threshold Thi level Dimming Control Comdor Function Same as Tridonic excel control gear Hytronik builds this function inside HEC7030 to achieve tri level dimming con
3. the detection area is set at Sensor OFF HEC7030 becomes a dimmable LED driver which can be dimmed 1 100 by push switch Absence Detection Function In many other cases people do not want to have a sensor to switch on the light automatically for example when people is just passing by there is no need to have the light on The solution is to apply absence detection by pressing the M A button on the remote control and manual initiation on the push switch the motion sensor remains active turns on and dims the light automatically and eventually switches it off in absence This is a good combination of sensor automation and maunal override control to have the maximum Light does not switch on Short push to activate With the manual short press on the energy saving and at the same time to keep when presence detected the sensor and switch push switch the sensor is activated efficient and comfortable lighting on the light and switches on the light B 80 Power Output Initia 10 000 Hours Due to deprecation of LED luminaire output after initial 10 000 hours this extra 20 10 000 hours can now be saved by pressing the Power 80 button on the remote control Deep energy saving Note it is required to return to 100 power output after the initial 10 000 hours by pressing the Power 100 button on the RC 9 LED Current Selections 200mA The current can be easily contigured by c
4. to be commissioned to the environment in which it is installed The latest action controls More details of the operation procedure please refer to user manual 8H Manual on Mode For LED Lamp Rapidly turn off on the power supply three times within 3 seconds the light will be 100 on for 8 hours and then goes to sensor mode automatically after 8 hours Useful when sensor function is not needed in special occasion Note this 8H manual on mode can be cancelled by turning off on the power supply one time within second fe ManualOvemde This sensor reserves the access of manual override function for end user to switch on off or adjust the brightness by push switch which makes the product more usertriendly and offers more options to fit for some extra ordinary demands Short push lt 1s on off function On off the light turns off immediately and can not be lighten for a certain time equals to holdtime preset even movement is detected After this period the sensor goes to sensor mode Off gt on the light turns on and goes fo sensor mode no matter if ambient Lux level exceeds the daylight threshold or not Long push gt 1s dim up down the hold ime brightness between 30 and 100 Both the settings on DIP switch and manual override can overwrite each other the latest action controls Note 1 if end user do not want this manual override function just leave the push terminal alone and don t connect it to any wire 2 if
5. 0 on RC S67 2057 3min lOmim ITEST 2s 30s 1min 5min 10min 30min on RCI 5lux 1Olux 50Lux disable 2Lux 10Llux 50Lux Lux disable on RC Os 10s 30min ee 0s 7 10s 7 Imin lOmin 80min ee on RCI 10 30 10 20 30 on RC 5 8GHz 7 5MHz lt O 2mW Max xH 8m x 5m 30 150 Max 5m 350mA 500mA 550mA 700mMA 750mA 900mA 10 60V 350mA 10 60V 500mA 10 55V 550mA 10 43V 700mA 10 40V 750mA 10 25V 9O0mA 3 5 21W 350mA 5 30W 500mA 5 5 30W 550mA 7 30W 700mA 7 30W 750mA 9 23W 9OOmA 7 OV 20 9 85 Max 20 C 50 C IG Output short circuit protection with auto reset Part 15B Wee 7 50 Semko CB EMC CE R amp TTE SAA Inputoutput 3750Vac SmA min IP20
6. Integrated SensorDIM LED Driver Daylight Monitoring Version Model HEC 7030 with HRC 05 LED LED 4 O Ienn A LED current selection Detection area Hold time Daylight threshold Stand b Stand by dimming level HYTRONIK period SS EXT EXT ail mii PUSH l 5 a inl mi Oa A ee ee ee ee A Extended antenna Model HEC7030 Antenna module connector Detection Pattern 0 Further 20 saving Daylight initial 8 hours 4 soft on soft off v Hold time 2 50Lux Ambient daylight Y 2s 30min threshold Monitoring 10 000 hrs sensorDIM manual on 2 in 1 and cost effective This is a smart integration of microwave motion sensor and multiple current selection LED driver which gives pre selected constant current to drive the LEDs to work based upon movement detection Designed in the software and thanks to our worldwide patented circuit the built in daylight sensor is prior to motion sensor so as to achieve utmost energy saving purpose With the detached sensor antenna SAMS it requires very little soace on the LED panel Only the antenna is installed on the surface while the mainbody can be hidden behind the panel Completely shadow free Detached sensor antenna module Model SAM5 Cable side entry Super compact sensor antenna with optional cable entry side entry and back entry Daylight sensor
7. ge to set detection range at 10 50 100 Hold time Press the buttons of hold time to set hold time at 30s Imin 5min 1Omin 30min Daylight sensor Press the buttons of daylight sensor to set daylight threshold at 2Lux 1OLux 50Lux Stand by penod comdor function Press the buttons of stand by period to set stand by period at Os 10s Imin 1Omin 30min 09 Note Os means on off control 29 means bilevel dimming control light never switches off when daylight sensor is disabled Stand by dimming level Press the buttons of stand by dimming level to set the stand by dimming level at 10 20 30 Wiring Diagram_Push Switch Dim O EE Detection Pattern Maximum Opcs Wiring Diagram_Push EXT Switch Dim Ceiling mounted height m Ceiling mounted detection pattern m Wall mounted height m Wall mounted detection pattern m O Detection area Detection area can be reduced by selecting the combination on the DIP switches to fit precisely for each specific application Note by choosing Sensor OFF it becomes a dimmable driver without sensor mode Hold time Hold time means the time period to keep the lamp on 100 after all motion has ceased detection area vacated Note the maximum brightness during hold ime can be overridden by long push on the push switch
8. hoosing 750mA 9 the correct combination of the DIP switches see eal A ble on the lef O 550mA H table on the let O Eal 500mA O KO 350mA 2 EE Current LED Maximum Load and Voltage This multiple current LED driver has a wide range of loading capacity 3 5 21W 350mA 5 30W 500m lt A 5 5 30W 550mA Maximum load different currents 7 30W 700m lt A 7 30W 750mA 9 23W Q9OOmA eas i diti 10 60V 350mA 10 60V 500mA 10 55V 550mA NS NON EE ST TOAN 700mA 1O240Vi750mA 10425V 900mAl Settings Remote Control HRC 05 eS Pemanent ON OFF function Press the ON OFF button the light goes to permanent on or permanent off mode sensor is disabled Press Auto Mode RESET or Scene mode buttons to quit from this mode Press Auto Mode button the sensor starts to work and all settings remain the same as the latest status before the light was switched on off Reset function Press RESET button all settings go back to the value of DIP switch settings Q OC Long press Dim or Dim to adjust the light brightness during hold time means dimming up i A means dimming down pL The button Test 2s is for testing purpose only The sensor goes to test mode hold time is 2s automatically after commissoning meanwhile the stand by period and daylight sensor are disabled This mode can be ended by pressing reset or any butt
9. on of scene mode and hold time The sensor setting is changed accordingly HYTRONIK oco Detection range W 100 i Stand by dimming level Y HRC O5 Note the buzzer beeps one time when RC receives signal successfully Manualovemde absence detection By pressing this button the sensor goes to manual override or absence detection function Note The buzzer beeps twice if it s manual override function and beeps once if shifts to absence detection function P P Power output By pressing these two buttons the output shifts between 80 at initial 10 000 hours and 100 tor energy saving purpose Lux disa ble Press this button the built in daylight sensor stops working and all motion detected could turn on the lighting fixture no matter how bright the natural light is Ambient daylight threshold Press this button the latest surrounding lux value overwrites previous lux value learned and is set as the daylight threshold This feature enables the fixture to function well in any real application circumstance Scene mode There are 4 scene modes fixed program built in the remote control to choose for different applications sea 1008 a E S SGe Note End user can adjust the settings by pressing buttons of detection range hold time stand by period stand by dimming level daylight sensor The lastest setting stays in validity Detection range Press the buttons of detection ran
10. trol for some areas that require a light change notice before switch olt It offers 3 levels of light 1O0 gt dimmed light 10 30 optional gt off With sufficient natural light With insufficient natural light After hold time the light dims The light switches off the light does not switch on it switches on the light when to stand by level or turns off automatically after the when movement detected person enters the room completely if surrounding stand by period elapsed natural light is above the daylight threshold Master Slave Group Control By connecting the EXT terminals in parallel maximum 1Opcs see wiring diagram no matter which sensor detects motion all HEC7O30 in the group will turn on the lights when surrounding natural light is below daylight threshold The sensor antenna is shared and the detection area could be widely enlarged in this way Other settings such as hold time stand by period stand by dimming level and daylight threshold on each individual unit stay the same Note if the surrounding natural light of the sensor which detects movement is sufficient all lights in the group will not be triggered on Ambient Daylight Threshold Switch the power supply to the sensor two times within 2 seconds the sensor can set the ambient lux level as the new threshold Both the settings on DIP switch and the ambient lux threshold learned can overwrite each other This feature enables the daylight sensor
Download Pdf Manuals
Related Search
Related Contents
Guía de usuario del Nokia 303 Manual del usuario Chem I Calibrator 1 - Support Manuel utilisateur - Fachgebiet Datenbanken und Informationssysteme GH-PM 40 P - Megekko.nl Ce que chacun devrait savoir IMPORTANTES INSTRUCCIONES SOBRE SEGURIDAD a [BAES + BAEH] Sati adressable encastré permanent Arcor 2 pour Copyright © All rights reserved.