Home
SIEMENS
Contents
1. the output signals of system A or B can be switched through to the interface board output The SB31 interface board can be used as changeover switch 3 Board design 8 channel changeover board which can be snapped onto a mounting rail Two 25 pin SUB D socket connectors X1 and X7 for analog signals from SIMADYN D 16 terminals X2 for process signals 2 terminals X2 for connecting the control power supply voltage 2 terminals X2 for connecting the control voltage 4 Application information 10V process signals up to 50 mA are permissible The SB31 interface board can be used to changeover the interface board No standard cable sets are provided for connecting the SIMADYN D systems to the interface board Siemens AG Dk Nr 285140 Edition 11 98 3 SIMADYN D Hardware User Manual Technical data 5 Technical data 5 1 General data INSULATION GROUP acc to VDE 0160 Draft came into force 12 90 60V DC rated insulation voltage AMBIENT TEMPERATURE 0 to 55 C STORAGE TEMPERATURE 40 to 70 C HUMIDITY CLASS acc to DIN 40040 F DEGREE OF PROTECTION acc to DIN 400501P00 MECHANICAL STRESSING acc to SN 29010 Class 12 MOUNTING SYSTEM Can be snapped onto mounting rails DIMENSIONS 118mm 135mm 42mm WEIGHT approx 350g 5 2 Electrical data PERMISSIBLE PROCESS SIGNAL VOLTAGE 10V max 50mA SWITCHING THRESHOLD AT THE CONTROL INPUT 4 5V CONTROL INPUT CURRENT 2mA at 24V CONTROL VOLTAGE SUPPLY 24V 5mA control inpu
2. damage can result Only appropriately qualified personnel may work on this equipment or in its vicinity This personnel must be completely knowledgeable about all the warnings and service measures according to this User Manual The successful and safe operation of this equipment is dependent on prope handling installation operation and maintenance Siemens AG Dk Nr 285140 Edition 11 98 1 SIMADYN D Hardware User Manual Warning information Definitions QUALIFIED PERSONNEL For the purpose of this User Manual and product labels a Qualified person is someone who is familiar with the installation mounting start up and operation of the equipment and the hazards involved He or she must have the following qualifications 1 Trained and authorized to energize de energize clear ground and tag circuits and equipment in accordance with established safety procedures 2 Trained in the proper care and use of protective equipment in accordance with established safety procedures 3 Trained in rendering first aid DANGER For the purpose of this User Manual and product labels Danger indicates death severe personal injury and or substantial property damage will result if proper precautions are not taken WARNING For the purpose of this User Manual and product labels Warning indicates death severe personal injury or property damage can result if proper precautions are not taken CAUTION For the purpose
3. SIEMENS SIMADYN D User Manual Digital Control System Interface board SA30 Edition 11 98 DK Nr 285140 User Manual Interface board SA30 Interface board SA30 11 93 Interface board SA30 09 94 Interface board SA30 05 95 Interface board SA30 04 97 Interface board SA30 11 98 Copying of this document and giving it to others and the use or communication of the contents thereof is forbidden without express authority Offenders are liable to the payment of damages All rights are reserved in the event of the grant of a patent or the registration of a utility model or design We have checked the contents of this Manual to ensure that they coincide with the described hardware and software However deviations cannot be completely ruled out so we cannot guarantee complete conformance However the information in this document is regularly checked and the necessary corrections included in subsequent editions We are thankful for any recommendations or suggestions Contents Contents Warning informationz sms Aa ANY dana dde a 1 1 Ordering information ui dado e da a 3 2 FUNCION Ae ANA BRA etal BINAN Naa were aNG 3 IB Te PAA 3 4 Application information ss arr as a UA BNG AD Paka EHER Re 3 Technical data NAE AA BG Aha ASANG GD Ka a Sab 4 Generada sai TANA added ceeded 4 5 2 Electrical data ate dados 4 6 COnhectorassignmenb aan Anand eal tay MA ld 4 6 1 Assignment SUB D socket connector X7 ussssssssnsnnnnnnnnn
4. dware User Manual Connector assignment 6 3 Assignment screw connector X2 Caution The assignment of terminals 31 to 34 deviates from the terminal assignment of the earlier SE34 board Analog signal 1 OV analog signal 1 Analog signal 2 OV analog signal 2 Analog signal 3 OV analog signal 3 Analog signal 4 OV analog signal 4 Analog signal 5 OV analog signal 5 Analog signal 6 OV analog signal 6 Analog signal 7 OV analog signal 7 Analog signal 8 OV analog signal 8 Control input Control input OV the same potential as term 33 Control voltage M24S Control voltage P24S 6 Edition 11 98 Siemens AG Dk Nr 285140 SIMADYN D Hardware User Manual 7 Attachments 7 1 Block diagram X 2 XT 11 12 o 11 1 de a 14 Ma i a o 21 12 2 8 gt 1T ra 21 gt o 18 e 2 14 o gt o 28 X 1 tO lad 1 1t Ta 14 r o 34 oil 8 gt d Li e Pal SEA o 33 7 2 Dimension drawing Dimension drawing Siemens AG Dk Nr 285140 Edition 11 98 SIMADYN D Hardware User Manual Attachments 3SE 465 681 9034 10 MB ECB instructions 8 ECB instructions Components which can be destroyed by electrostatic discharge ECB Generally electronic boards should only be touched when absolutely necessar
5. n kerner ere ts 4 6 2 Assignment SUB D socket connector X uussesssensnnnnnnennn kernerne es 5 6 3 Assignment screw connector X2 esssnennnssssnnnnnnnn kernerne re keen 6 TAE NEETA O ON 7 LY Blockdiagram iaa laci n 7 1 2 DIMENSION AMINO aldea 7 8 EGB NSTUCIONS ua AE AE A 8 Siemens AG Dk Nr 285140 Edition 11 98 SIMADYN D Hardware User Manual Warning information Edition 11 98 Siemens AG Dk Nr 285140 SIMADYN D Hardware User Manual Warning information NOTE The information in this Manual does not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes please contact your local Siemens office Further the contents of this Manual shall not become a part of or modify any prior or existing agreement commitiment or relationship The sales contract contains the entire obligation of Siemens The warranty contained in the contract between the parties is the sole warranty of Siemens Any statements contained herein do not create new warranties nor modify the existing warranty Warning information WARNING Electrical equipment has components which are at dangerous voltage levels If these instructions are not strictly adhered to severe bodily injury and material
6. of this User Manual and product labels Caution indicates that minor personal injury or material damage can result if proper precautions are not taken x NOTE For the purpose of this User Manual Note indicates information about the product or the respective part of the User Manual which is essential to highlight CAUTION This board contains components which can be destroyed by electrostati discharge Prior to touching any electronics board your body must be electrically discharged This can be simply done by touching a conductive grounded object immediately beforehand e g bare metal cabinet components socket protective conductor contact WARNING Hazardous voltages are present in this electrical equipment during operation Non observance of the safety instructions can result in severe personal injury or property damage It is especially important that the warning information in all of the relevant Operating Instructions are strictly observed 2 Edition 11 98 Siemens AG Dk Nr 285140 SIMADYN D Hardware User Manual Ordering information 1 Ordering information SA30 6DD 1681 0DE1 2 Function description The SA30 interface board is used in the SIMADYN D system as output without electrical isolation for system side analog signals with a 10V signal level The interface board has two 25 pin SUB D connectors for connecting the output signals of two redundant SIMADYN D systems A and B Using a control input
7. t lt 4 5V 24V 56mA control input gt 4 5V 6 Connector assignment 6 1 Assignment SUB D socket connector X7 Analog signal 1 system A OV analog signal 1 system A Analog signal 2 system A OV analog signal 2 system A Analog signal 3 system A OV analog signal 3 system A Analog signal 4 system A OV analog signal 4 system A Analog signal 5 system A OV analog signal 5 system A Analog signal 6 system A OV analog signal 6 system A Analog signal 7 system A OV analog signal 7 system A Analog signal 8 system A OV analog signal 8 system A Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned 4 Edition 11 98 Siemens AG Dk Nr 285140 SIMADYN D Hardware User Manual Connector assignment 6 2 Assignment SUB D socket connector X1 Analog signal 1 system B OV analog signal 1 system B Analog signal 2 system B OV analog signal 2 system B Analog signal 3 system B OV analog signal 3 system B Analog signal 4 system B OV analog signal 4 system B Analog signal 5 system B OV analog signal 5 system B Analog signal 6 system B OV analog signal 6 system B Analog signal 7 system B OV analog signal 7 system B Analog signal 8 system B OV analog signal 8 system B Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Siemens AG Dk Nr 285140 Edition 11 98 5 SIMADYN D Har
8. y The human body must be electrically discharged before touching an electronic board This can be simply done by touching a conductive grounded object directly beforehand e g bare metal cubicle components socket outlet protective conductor contact Boards must not come into contact with highly insulating materials e g plastic foils insulated desktops articles of clothing manufactured from man made fibers Boards must only be placed on conductive surfaces When soldering the soldering iron tip must be grounded Boards and components should only be stored and transported in conductive packaging e g metalized plastic boxes metal containers If the packing material is not conductive the boards must be wrapped with a conductive packing material e g conductive foam rubber or household aluminum foil The necessary ECB protective measures are clearly shown in the following diagram a Conductive floor surface d ECB overall b ECB table e ECB chain c ECB shoes f Cubicle ground connection 8 Edition 11 98 Siemens AG Dk Nr 285140 SIMADYN D Hardware User Manual ECB instructions Siemens AG Dk Nr 285140 Edition 11 98 9 SIMADYN D Hardware User Manual ECB instructions Drives and Standard Products Motors and Drives Systems Group Postfach 3269 D 91050 Erlangen System Based Technology 10 Edition 11 98 Siemens AG Dk Nr 285140 SIMADYN D Hardware User Manual
Download Pdf Manuals
Related Search
SIEMENS siemens siemens healthineers siemens nx siemens energy siemens careers siemens gpt siemens mobility siemens industry mall siemens login siemens logo siemens support center siemens ceo siemens industry inc siemens webshop siemens plc siemens eda siemens support siemens imall siemens mall siemens breakers siemens pepconnect siemens document library siemens gamesa siemens healthineers careers siemens portal
Related Contents
DEH-P6050UB (Português) Baixe ewaq-g-_iom_d-eimac01207-15fr Amana AER5515QA Electric Kitchen Range boulons de roue, jante en acier WS831DL User Manual - Test Equipment Depot NuTone VSC4R User's Manual WinBraille 5.0 Syndrome myélodysplasique et EPO - Geronto Copyright © All rights reserved.
Failed to retrieve file