Home

20P601-00 E4 User Manual

image

Contents

1. Function BI_Dx in out Differential pairs of data lines for 1000Base T RX in Differential pair of receive data lines for 10 100Base T TX out Differential pair of transmit data lines for 10 100Base T Connector types e Modular 8 8 pin mounting jack according to FCC68 e Mating connector Modular 8 8 pin plug according to FCC68 MEN Mikro Elektronik GmbH 12 20P601 00 E4 2013 07 26 Connecting the XMC 2 2 Host PCI Interface The P601 supports two PCI Express links with four lanes each on XMC connector P15 Note This pin assignment is not compliant to the XMC standard VITA 42 3 200x The standard only supports one link with up to eight lanes per XMC connec tor In the following you find the pin assignment of the 114 pin XMC plug connector P15 Table 4 Pin Assignment of 114 pin XMC Connector P15 F E D C B A 1 VPWR PETOn1 PETOp1 3 3V PETOnO PETOpO 2 MRSTI GND GND GND GND 3 VPWR PETOn3 PETOp3 3 3V PETOn2 PETOp2 4 MRSTO GND GND TCK GND GND 5 VPWR PETin1 PET1p3 3 3V PET1nO PET1p0 EEEEEE 6 GND GND TMS GND GND oose5 7 VPWR PET1n3 PET1p3 3 3V PET1n2 PET1p2 e 8 GND GND TDI GND GND iS o vewR GAO GND GND TDO GND GND Reco 11 VPWR PEROn1 PEROp1 PEROn0 PEROpO eE 12 MPRESENT GND GND GA1 GND GND ae Bog 13 VPWR PEROn3 PEROp3 PEROn2 PEROp2 E a 14 MSDA GND GND GA2
2. GmbH All rights reserved Germany MEN Mikro Elektronik GmbH Neuwieder StraBe 3 7 90411 Nuremberg Phone 49 911 99 33 5 0 Fax 49 911 99 33 5 901 E mail info men de www men de MEN Mikro Elektronik GmbH 20P601 00 E4 2013 07 26 France MEN Mikro Elektronik SA 18 rue Ren Cassin ZA de la Chatelaine 74240 Gaillard Phone 33 0 450 955 312 Fax 33 0 450 955 211 E mail info men france fr www men france fr USA MEN Micro Inc 24 North Main Street Ambler PA 19002 Phone 215 542 9575 Fax 215 542 9577 E mail sales menmicro com www menmicro com Contents Contents L Getting Started i sdccodeutenbiegs cae caoseas i tate thio oeee sewers 11 LI MapOt the Board EE sonia Qiaws 11 1 2 Integrating the Board into a System 008 11 13 Installing Driver Sottware cas 4 085 beannes usare aapakan ES 11 2 Connecting the 12 2 1 Peripheral Interfaces ss ci0c104 estedene ould tukena pen 12 22 Host POLIMENI E E E yates 13 3 Functional Description 06 6 0 0 ce esse dies tesco wee e da eens 15 Sol Power Supply scus sncee 4 ERRE 15 32 Ethernet 15 a2 iBthemet Controliieee eae ea 15 322 Thermal Considerations ssu6c pccnsceavasdcareasdve 15 4 ApPendixiras 16 4 1 Literature and Web Resources 0 0 0 0 cece eee eee eee 16 QW Gas AE a A oe 16 4A PCLEXPICSS c22i0c1r ed osangaocddapmacne neta eens 16 4 2 Finding out the Board s Article Number Revision an
3. 20P601 00 E4 2013 07 26 P601 Quad Redundant Gigabit Ethernet XMC MEN P601 Quad Redundant Gigabit Ethernet XMC P601 Quad Redundant Gigabit Ethernet XMC The P601 is a Gigabit Ethernet XMC mezzanine card suitable for any XMC compliant single board computer or host carrier board in any type of bus system i e CPCI VME or on any type of stand alone SBC Compared to PMC the XMC standard defines a different board to board connector for support of PCI Express The four Ethernet channels on the P601 are provided by two Ethernet controllers with two lines each and supported by two PCIe links with four lanes each With a specific set up the two lines inside each Ethernet controller can be used as a redundant channel pair In this mode one line is monitored by the other line and the controller recognizes when an error occurs The mezzanine module P601 is typically suited as an extension for Windows and Linux based systems with a heavy demand for multiple and ultra fast communication requirements As such it is used in high bandwidth multi channel communication applications in networked appliances such as base stations routers switches gateways residential gateway controllers etc Main target markets comprise telecom medical engineering and transportation For use in rugged environments the P601 is delivered with a passive heat sink and is prepared for conformal coating Equipped with Intel components that come ex
4. 4 A typ 5 V 600 mA typ 12 V 3 3 V 5 5 100 mA typ Mechanical Specifications e Dimensions conforming to XMC standard VITA 42 0 200x e Weight 104 g with heat sink Environmental Specifications e Temperature range operation 0 455 C Industrial temperature range on request Airflow min 10m h e Temperature range storage 40 85 C e Relative humidity operation max 95 non condensing e Relative humidity storage max 95 non condensing e Altitude 300 m to 3000 m MEN Mikro Elektronik GmbH 4 20P601 00 E4 2013 07 26 Technical Data e Shock 15 g 11 ms e Bump 10 g 16 ms e Vibration sinusoidal 2 g 10 150 Hz e Conformal coating on request MTBF e 920 841h 40 C according to IEC TR 62380 RDF 2000 Safety e PCB manufactured with a flammability rating of 94V 0 by UL recognized manu facturers EMC e Tested according to EN 55022 radio disturbance IEC1000 4 2 ESD and IEC1000 4 4 burst Software Support e Drivers from Intel for Windows and Linux MEN Mikro Elektronik GmbH oJ 20P601 00 E4 2013 07 26 Product Safety Product Safety A Electrostatic Discharge ESD Computer boards and components contain electrostatic sensitive devices Electrostatic discharge ESD can damage components To protect the board and other components against damage from static electricity you should follow some precautions whenever you work on your computer Power dow
5. GND GND 15 VPWR PERin1 PER1p1 i PER1nO PER1p0 16 MSCL GND GND MVMRO GND GND 17 PER1n3 PER1p3 PER1n2 PER1p2 18 GND GND GND GND 19 WAKEO r REFCLK 0 REFCLK 0 Connector e 114 pin XMC plug connector e g SAMTEC ASP105885 01 e Mating connector 114 pin XMC receptacle connector MEN Mikro Elektronik GmbH 13 20P601 00 E4 2013 07 26 Connecting the XMC Table 5 Signal mnemonics of 114 pin XMC connector Signal Direction Function Power VPWR in Variable power pins 5V or 12V supply voltage 3 3V in 3 3V supply voltage GND Ground PCI PEROp n 0 3 in PCI Express link 0 differential receive Express lanes 0 3 Link 0 PETOp n 0 3 out PCI Express link O differential transmit lanes 0 3 REFCLK 0 in Differential reference clock WAKE in Reactivation of power rails and refer ence clocks PCI PER1p n 0 3 in PCI Express link 1 differential receive Express lanes 0 3 Link 1 PET1p n 0 3 out PCI Express link 1 differential transmit lanes 0 3 Other GA O 2 in 12C channel select MSCL in IPMI 12C serial clock MPRESENT _ out Module present MRSTI in XMC reset in MRSTO out XMC reset out MSDA in out IPMI I2C serial data MVMRO in XMC write prohibit MEN Mikro Elektronik GmbH 20P601 00 E4 2013 07 26 Functional Description 3 Functional Description A 3 1 Power Supply The P601 is supplied via the carrier board The
6. Use Field of Application The correct function of MEN products in mission critical and life critical applications is limited to the environmental specification given for each product in the technical user manual The correct function of MEN products under extended environmental conditions is limited to the individual requirement specification and subsequent validation documents for each product for the applicable use case and has to be agreed upon in writing by MEN and the customer Should the customer purchase or use MEN products for any unintended or unauthorized application the customer shall indemnify and hold MEN and its officers employees subsidiaries affiliates and distributors harmless against all claims costs damages and expenses and reasonable attorney fees arising out of directly or indirectly any claim or personal injury or death associated with such unintended or unauthorized use even if such claim alleges that MEN was negligent regarding the design or manufacture of the part In no case is MEN liable for the correct function of the technical installation where MEN products are a part of Trademarks All products or services mentioned in this publication are identified by the trademarks service marks or product names as designated by the companies which market those products The trademarks and registered trademarks are held by the companies producing them Inquiries concerning such trademarks should be made directly to those co
7. clusively from the Intel Embedded Line the P601 has a guaranteed minimum standard availability of 5 years MEN Mikro Elektronik GmbH 2 20P601 00 E4 2013 07 26 Diagram Electrical isolation RJ45 RJ45 RJ45 RJ45 MEN Mikro Elektronik GmbH 20P601 00 E4 2013 07 26 Ethernet 10 100 1000Base T Controller Ethernet 10 100 1000Base T Controller Diagram PCle x4 XMC Connector P15 Serial EEPROM Technical Data Technical Data Ethernet e Four 10 100 1000Base T Ethernet channels at front panel e RJ45 connectors at front panel e Two independent dual port Ethernet controllers Fully integrated Gigabit Ethernet Media Access Controllers MAC and physical layer ports PHY 48 kB per port on chip packet buffer Full duplex and half duplex operation e Ethernet controllers are connected by two PCIe links with four lanes each e Two LEDs per channel to signal LAN Link Activity status and connection speed 10 100 1000Base T XMC Characteristics XMC connector P15 assembled Peripheral Connections e Via front panel on four RJ45 connectors PCI Express Two links with four lanes each to connect local 1000Base T Ethernet controllers 1 GB s per channel in each direction Both links on XMC connector P15 Electrical Specifications e Isolation voltage 1 5 kV DC electrical isolation between isolated side and digital side e Supply voltage power consumption 5 V or 12 V 5 5 1
8. d Seral NUMDET s lt ios 3 care taints 16 Figures Figure 1 Map of the board top view 0 0 cece eee eee eee 11 Figure 2 Labels giving the board s article number revision and Serial HUME g 5 c 60 8 arsena 66 16 Tables Table 1 Status LEDs of 8 pin RJ45 Ethernet 10 100 1000Base T connectors LAN A LAND 12 Table 2 Pin assignment of 8 pin RJ45 Ethernet 10 100 1000Base T onnectors 12 Table 3 Signal mnemonics of Ethernet 10 100 1000Base T connectors 12 Table 4 Pin Assignment of 114 pin XMC Connector P15 13 Table 5 Signal mnemonics of 114 pin XMC connector 14 MEN Mikro Elektronik GmbH 7777777777777777 77777777 I 0 20P601 00 E4 2013 07 26 Getting Started 1 Getting Started This chapter gives an overview of the board and some hints for first installation in a system 1 1 Map of the Board Figure 1 Map of the board top view Heat sink XMC connector P15 1 2 Integrating the Board into a System You can use the following check list to install the XMC on a carrier board for the first time and to test proper functioning of the board MI Power down the system and remove the XMC carrier board M Install the XMC in a suitable slot of the carrier board as described in the carrier board s user manual MI Insert the carrier board into the syste
9. es no warranty representation or guarantee of any kind regarding the suitability of its products for any particular purpose nor does MEN assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability including without limitation consequential or incidental damages TO THE EXTENT APPLICABLE SPECIFICALLY EXCLUDED ARE ANY IMPLIED WARRANTIES ARISING BY OPERATION OF LAW CUSTOM OR USAGE INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE OR USE In no event shall MEN be liable for more than the contract price for the products in question If buyer does not notify MEN in writing within the foregoing warranty period MEN shall have no liability or obligation to buyer hereunder The publication is provided on the terms and understanding that 1 MEN is not responsible for the results of any actions taken on the basis of information in the publication nor for any error in or omission from the publication and 2 MEN is not engaged in rendering technical or other advice or services MEN expressly disclaims all and any liability and responsibility to any person whether a reader of the publication or not in respect of anything and of the consequences of anything done or omitted to be done by any such person in reliance whether wholly or partially on the whole or any part of the contents of the publication Conditions for
10. gs concerning the use of voltages which can lead to serious damage to your health and also cause damage or destruction of the component This sign marks important notes or warnings concerning proper functionality of the product described in this document You should read them in any case Folder file and function names are printed in italics Bold type is used for emphasis A monospaced font type is used for hexadecimal numbers listings C function descriptions or wherever appropriate Hexadecimal numbers are preceded by Ox Comments embedded into coding examples are shown in green color Hyperlinks are printed in blue color The globe will show you where hyperlinks lead directly to the Internet so you can look for the latest information online Signal names followed by or preceded by a slash indicate that this signal is either active low or that it becomes active at a falling edge Signal directions in signal mnemonics tables generally refer to the corresponding board or component in meaning to the board or component out meaning coming from it Vertical lines on the outer margin signal technical changes to the previous issue of the document MEN Mikro Elektronik GmbH 7 20P601 00 E4 2013 07 26 About this Document Legal Information Changes MEN Mikro Elektronik GmbH MEN reserves the right to make changes without further notice to any products herein Warranty Guarantee Liability MEN mak
11. m again MI Power up the system M If there is a system crash or other abnormal behavior at start up check if the XMC is plugged properly M You can now install driver software for the P601 1 3 Installing Driver Software For a detailed description on how to install driver software please refer to the respective documentation T You can find any driver software available for download on MEN s website MEN Mikro Elektronik GmbH 11 20P601 00 EA 2013 07 26 Connecting the XMC 2 Connecting the XMC 2 1 Peripheral Interfaces You can connect peripherals via the four RJ45 Ethernet front connectors There are two status LEDs for each channel at the front panel which signal LAN link activity status and connection speed They are assigned to the four connectors in the following way Table 1 Status LEDs of 8 pin RJ45 Ethernet 10 100 1000Base T connectors LAN_A LAN_D Green LED On Link 100 Mbits s Off Link with 10 Mbits s or AA AE EAA AN 1000 Mbits s LAN_A S LAN_D Orange LED LAN_B lis itis ME ME LAN_C Blinks whenever there is transmit or receive activity Table 2 Pin assignment of 8 pin RJ45 Ethernet 10 100 1000Base T connectors LAN_A LAN_D 1000Base T 10 100Base T 1 BI_DA TX 2 BI_DA TX 3 BI_DB RX 4 BI_DC J 5 BI_DC 6 BI_DB RX 7 BI_DD 8 BI_DD Table 3 Signal mnemonics of Ethernet 10 100 1000Base T connectors Signal Direction
12. mpanies Conformity MEN products are no ready made products for end users They are tested according to the standards given in the Technical Data and thus enable you to achieve certification of the product according to the standards applicable in your field of application MEN Mikro Elektronik GmbH amp 20P601 00 E4 2013 07 26 About this Document RoHS Since July 1 2006 all MEN standard products comply with RoHS legislation Since January 2005 the SMD and manual soldering processes at MEN have already been completely lead free Between June 2004 and June 30 2006 MEN s selected component suppliers have changed delivery to RoHS compliant parts During this period any change and status was traceable through the MEN ERP system and the boards gradually became RoHS compliant WEEE Application The WEEE directive does not apply to fixed industrial plants and tools The compliance is the responsibility of the company which puts the product on the market as defined in the directive components and sub assemblies are not subject to product compliance In other words Since MEN does not deliver ready made products to end users the WEEE directive is not applicable for MEN Users are nevertheless recommended to properly recycle all electronic boards which have passed their life cycle Nevertheless MEN is registered as a manufacturer in Germany The registration number can be provided on request Copyright 2013 MEN Mikro Elektronik
13. n and unplug your computer system when working on the inside Hold components by the edges and try not to touch the IC chips leads or cir cuitry Use a grounded wrist strap before handling computer components Place components on a grounded antistatic pad or on the bag that came with the component whenever the components are separated from the system Store the board only in its original ESD protected packaging Retain the original packaging in case you need to return the board to MEN for repair MEN Mikro Elektronik GmbH 6 20P601 00 E4 2013 07 26 About this Document About this Document italics bold monospace comment hyperlink pe T IRQ IRQ in out This user manual is intended only for system developers and integrators it is not intended for end users It describes the hardware functions of the board connection of peripheral devices and integration into a system It also provides additional information for special applications and configurations of the board The manual does not include detailed information on individual components data sheets etc A list of literature is given in the appendix History Issue Comments Date E1 First edition 2006 04 12 E2 Pin assignment of XMC connector corrected 2008 04 09 E3 Corrected Chapter 3 1 Power Supply on page 17 2012 03 02 E4 Corrected order of Ethernet ports 2013 07 17 Conventions This sign marks important notes or warnin
14. ntains superior performance In addition using hardware acceleration the controller offloads tasks from the host such as TCP UDP IP checksum calculations and TCP segmentation The controller can be used in redundancy mode for high availability reliability and safety In addition it provides a Serializer Deserializer SerDes for optical fiber and backplane applications as well as SMB and FML management ports for support of a Board Management Controller BMC 3 2 2 Thermal Considerations The P601 Ethernet controllers are equipped with an extra heat sink which is fastened on the top side with three screws Note MEN gives no warranty on functionality and reliability of the P601 if you use any other heat sink than that supplied by MEN Please contact either MEN directly or your local MEN sales office MEN Mikro Elektronik GmbH 15 20P601 00 E4 2013 07 26 Appendix 4 Appendix 41 Literature and Web Resources e P601 data sheet with up to date information and documentation www men de 4 1 1 XMC e XMC PCI Express Protocol Layer Standard VITA 42 3 2006 June 2006 VMEbus International Trade Association www vita com e Standard for VITA 42 0 XMC VITA 42 0 2008 December 2008 VMEbus International Trade Association www vita com 4 1 2 PCI Express e PCI Special Interest Group Wwww pcisig com 4 2 Finding out the Board s Article Number Revision and Serial Number MEN user documentation may describe several differen
15. re are two supply voltages needed 3 3 V and VPWR VPWR must be 5 V or 12 V The input currents at the P15 XMC connector are 1 4 A 10 with VPWR at 5 V or 0 6 A 10 with VPWR at 12 V 100 mA 10 are consumed at 3 3 V A wide range switching power supply generates the Ethernet controller supply voltages These voltages have a value of 1 8 V with a current of 2 2 A 10 and 1 1 V with a current of 2 2 A 10 3 2 Ethernet Interfaces The P601 is equipped with two dual port gigabit Ethernet controllers and with a PCI Express interface according to the XMC standard 3 2 1 Ethernet Controller The P601 is equipped with the Intel 82571EB Ethernet Controller It is a single compact component with two fully integrated Gigabit Ethernet Media Access Controllers MAC and physical layer ports PHY The device uses the PCI Express architecture The Intel 82571EB provides a standard IEEE 802 3 Ethernet interface for 1000Base T 100Base TX and 10Base T applications 802 3 802 3u and 802 3ab The Gigabit Ethernet Controller with PCI Express architecture is designed for high performance and low memory latency The device is optimized to connect to a system using four PCI express lanes x4 PCI Express interface Alternatively the controller can use one PCI Express lane Wide internal data paths eliminate performance bottlenecks by efficiently handling large address and data words A large 48 kB per port on chip packet buffer mai
16. t models and or hardware revisions of the P601 You can find information on the article number the board revision and the serial number on two labels attached to the board e Article number Gives the board s family and model This is also MEN s order ing number To be complete it must have 9 characters e Revision number Gives the hardware revision of the board e Serial number Unique identification assigned during production If you need support you should communicate these numbers to MEN Figure 2 Labels giving the board s article number revision and serial number Complete article number 15P601 00 O yt 00 00 00 641517 Serial Revision number MEN Mikro Elektronik GmbH 16 20P601 00 E4 2013 07 26

Download Pdf Manuals

image

Related Search

Related Contents

HRT445IP - Deatronic srl    Access Rail Manual - 2010 to present  5 - Parent Directory  BT MA E BTB MA  Secure Payment Form V2 Internet Merchant  API QUÍMICA Y TESTS DEL AGUA  Samsung PS-42S4S Brugervejledning  Samsung 375 Litros Combinado no frost RL58GEGMG manual de utilizador  85024A High Freq Probe User`s and Service Guide  