1. CEC Provide additional protection for indicators that may be damaged in service Maintenance Note The following applies to all instruments of the DPI 705 Series Return the instrument to the factory for any repairs it cannot be repaired on site To keep the DPI 705 accurate to 0 1 full scale a calibration check should be carried out once per year Cleaning Clean the instrument case with a moist lint free cloth and weak detergent K0214 Issue No 5 4 Calibration Instructions WARNING CALIBRATE DPI 705 IS INSTRUMENTS IN A SAFE AREA The instrument performs a two point compensation at ZErO and FS full scale Preparation Connect the instrument to a pressure source that has an accuracy three times better than the AS instrument Doo c Recommended Druck DPI 610 or DPI 610 IS Portable Calibrator 2 Switch on the instrument and select the units of pressure measurement required for calibration Procedure 1 Apply zero pressure Press all three keys when stable New PIN QO together to enter the et CAL menu and proceed as S shown 9 7 3 beeps P new PIN accepted Set value using to A S E scale and er to decrease J 4 Apply full scale pressure when stable y 2 Repeat the setting to confirm Changing the PIN the new PIN Each digit can be changed ard in turn o incr 3 beeps Pressing ane alibration accepted PEND _ END amp increa
2. S C absolute ranges only erai gt 1 bar 0 02 FS C absolute ranges only Operating POUNG Ss asastsss iss ssiertstsssse trdietinsiiradinnadiannsanes 10 C to 50 C 15 F to 120 F GLOlOGE FOND smsan E A A 20 C to 60 C 5 F to 140 F Maximum safe working preSSure oases cect scsssiscrssrctcdessertarnranstenaanadnaceneisinesesssnimact 2 x full scale Pressure CONNECHOF caches dared ere lens ase diceccescceccescccenek 6 mm o d and 4 mm i d hose EEEE RETER ERE EEEE EERE G1 8 or 1 8 NPT female thread MAX MUM tOTQUE scent ct vena dra eevee aanavesian 2 259 Nm 20 Ib in ENVILONMEMOA enrera E R IP54 NEMA 12 Electrical safety enue ne ee ne eee ne rere ern BS EN 61010 as applicable Electromagnetic compatibility sass isdnnndiannnannanneaenniass EN50081 1 emissions ee ee eee EN50082 2 immunity Electrical Power Supply for non Certified units eeeeseccessssseeesssscsesssneeeeeee 3 x 1 5 V alkaline size AA Safety This symbol on the pressure indicator indicates that the user should refer to the user guide or manual Pressure Do not apply pressure greater than the maximum safe working pressure Do not apply pressure greater than 1 1 bar 15 95 psi absolute to the ve pressure port of differential pressure indicators Batteries Remove batteries from the pressure indicator immediately when discharged and before storage Dispose of batteries in accordance with local regulations and battery manufacturers instructions When s
3. Test Equipment 99 Washington Street Depot Melrose MA 02176 Phone 781 665 1400 1 800 517 8431 Toll Free 1 800 517 8431 GE Sensing amp Inspection Technologies Druck DPI 705 DPI 705 IS Series Digital Pressure Indicator User Manual K0214 Tud 1088 Pressure indicator English 1 6 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com GE Druck EC Declaration of Conformity Product DPI 705 705 IS DIGITAL PRESSURE INDICATOR The above product s meets the protection requirements of the relevant EC Directives Supplier Druck Ltd Fir Tree Lane Groby Leicester LE6 0FH Tel 44 0 116 231 7100 Fax 44 0 116 231 7101 Signed A deve Date 3 beconler Zon 3 For and on behalf of Druck Limited Name R Jones Position Group Engineering Director Relevant European Directives 97 23 EC Category SEP Potentially Explosive Atmospheres 94 9 EC f The ATEX directive only applies to instruments marked with BASO2ZATEX1 194 Standards Safety requirements for electrical equipment EN61010 1 1993 for measurement control and laboratory use Electromagnetic Compatibility EN50081 1 1992 and EN50082 2 1995 Electrical apparatus for explosive atmospheres EN60079 0 2006 General Requirements Electrical apparatus for potentially explosive EN60079 11 2007 i atmospheres intrinsic safety 1 Explosive atmospheres Equipment with EN60079 26 2007
4. equipment protection level EPL Ga These standards only apply to instruments marked with BASOZATEX1 194 Pagel of I CD0043 Issue 05A The General Electric Company All rights reserved Approved Service Agents For the list of service centres visit our web site Symbols This equipment meets the requirements of all relevant European safety directives The equipment carries the CE mark This symbol on the instrument indicates that the user should refer to the user manual Do not dispose of this product as household waste Use an approved organisation that collects and or recycles waste electrical and electronic equipment For more information Contact us at www gesensinginspection com Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com K0214 Issue No 5 DPI 705 Series Digital Pressure Indicator Introduction The Druck DPI 705 pressure indicator uses a micro machined silicon transducer to produce a pressure reading in units of pressure measurement These user instructions include the operations for all DPI 705 Pressure Indicators safety instructions and the requirements for intrinsically safe instruments Specification Accuracy Combined non linearity hysteresis and repeatability eeceeeeee 0 1 full scale FS Temperature effects SOOM iinuinndennsiswensdeminnemunmaineannnasanamaiane 0 02 rdg C LIEV a sscaisivenecthenchenescronens lt 1 bar 0 05 F
5. n The instrument counts down 60 seconds displaying the leakage at the end of the 60 second period Press the LEAK key at any time during the leak test to quit and return to normal measurement ZERO A zero should be performed on gauge and differential instruments before measuring pressure To perform a zero Open all pressure ports to atmospheric pressure Press the and TARE keys together the display briefly shows ZErO and the instrument calculates a new zero Note A zero can only be performed on absolute pressure indicators if a vacuum is first applied to the pressure port Alarm A single alarm can be set to operate when the displayed pressure value rises above the alarm setting The alarm causes the display to flash and a beeper to sound for one minute Pressing TARE and UNITS keys together displays the alarm value pressing the FILTER key increases the alarm value pressing the UNITS key decreases the alarm value When the display shows the required alarm value press the TARE key to set the alarm K0214 Issue No 5 2 Intrinsically Safe Pressure Indicators Introduction These instructions detail the requirements for using the DPI 705 Intrinsically Safe Pressure Indicator in a hazardous area Read the whole publication before starting Special note This instrument has been certified by ATEX and CSA The batteries certflied for use by each certifying body are different It is the user s responsibility to use the correct batterie
6. s Installation Requirements in Hazardous Areas ATEX Certification Markings Ex ia IIC T4 Ga 10 C lt Ta lt 50 C 00 hazardous location markings BASO2ATEX1194 vaireticdccsdverperiarssredateasiansiassl certificate number Ex I 1G o equipment group and category C T180 apiece eres CE mark DPI705 IS scssiasscesssovencesesienceassssnntasnsssasessossssocsenes specific apparatus type Pressure range in mbar or psi s0s0000 full scale pressure rating Druck LTD Groby LE6 OFH UK 068 manufacturer s name and address SN YY MM sa cesscensntnvnnnsnave sseseseveseoveneenieses serial number and date of manufacture year month Requirements and Conditions Batteries WARNING ONLY REPLACE BATTERIES IN A SAFE AREA Power supply only use 3 x LR6 AA Duracell PROCELL Duracell PLUS ENERGIZER ULTIMATE or GP SUPERALKALINE Installation WARNING Do NOT USE TOOLS ON THE PRESSURE INDICATOR THAT MIGHT CAUSE INCENDIVE SPARKS THIS CAN CAUSE AN EXPLOSION Installation should be carried out by qualified plant installation technicians in compliance with the latest issue of EN 60079 14 Provide additional protection for indicators that may be damaged in service Declaration Requirements The DPI 705 IS is designed and manufactured to meet the essential health and safety requirements not covered by EC Type Examination Certificate BASO2ATEX1194 when installed as detailed above This in
7. ses the value of the digit steps to next digit On QD enters the PIN 5 K0214 Issue No 5 from calibration menu after pressing oS CSU Software Enter PIN 596 Software version Pressure measurement units PECE set ON or OFF selected On Off in turn each unit S ane selected 3 beeps Pressure setting aeie measurement D Goes back to calibration menu overleaf The LOCKED pressure indicator only measures pressure temperature in the selected units and does not process data Alarm leak and other process functions are not available 3 beeps Pressure setting accepted measurement Lock units On Off Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com
8. toring and transporting batteries make sure they cannot be short circuited Cleaning Clean the pressure indicator with a damp cloth Calibration Refer to the Calibration and Configuration Instructions Software Version This manual contains operating instructions for pressure indicators with software version 1 02 onwards Further changes to the pressure indicator s software may require a change to the operating instructions and an issue number change of the manual 1 K0214 Issue No 5 Display Symbols ee Batteries are low replace Filter applied EM observing polarity shown on case 10 reading rolling average TARE Tare applied A Displayed reading maximum value A Alarm pressure value v Displayed reading minimum value flashing more than alarm setting 1 gt _ Displayed reading leakage per Q a XE minute i Switch Tare on or off changes the Change units 1 of 16 display reading to zero pressure we C or F Switch filter on or off View maximum minimum or pertola leak test max min is reset at O switch on Switch Operation on or off TIME OUT If a key is not pressed within 10 minutes then the instrument times out and switches off To disable this automatic time out hold the LEAK key when switching on the pressure indicator LEAK TEST To perform a leak test press the LEAK key 3 times The E gt symbol flashes on the display with the number 60 To start the leak test press He LEAK key agai
9. trinsically safe instrument is designed and manufactured to protect against other hazards as defined in paragraph 1 2 7 of Annex II of the ATEX Directive 94 9 EC Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com English CSA Certification Markings Ex ia IIC T4 Class 1 Zone 0 and Class 1 Div 1 Groups A B C amp D wucnduananscesnnsasencrees hazardous location designation 1999 LR110032 3 5 sas risssivi ca acieesiocaeseaonesvem ennai certificate reference Amb Temp 10 C to 50 C ee eeesssssssceeetcseeeeeeeees ambient temperature range S p Mea saana sane CSA monogram DPI705 IS esiet tee uee ESEE eo esee EES nS specific apparatus type Pressure range in mbor or psi sesssssssesesssessessessesee full scale pressure rating Druck LTD Groby LE6 OFH UK ssssesssessssesesssssseses manufacturer s name and address SN AEE YV PER ORDO Re OM eee ERROR eRe NAO SOE serial number and date of manufacture year month Requirements and Conditions Batteries WARNING ONLY REPLACE BATTERIES IN A SAFE AREA Power supply use only 3 x LR6 AA made by Eveready Energizer LR6 Varta 4006 or Duracell Procell MN1500 Installation WARNING Do NOT USE TOOLS ON THE PRESSURE INDICATOR THAT MIGHT CAUSE INCENDIVE SPARKS THIS CAN CAUSE AN EXPLOSION Installation should be carried out by qualified plant installation technicians in compliance with the latest issue of Canadian Electrical Code
Download Pdf Manuals
Related Search
Related Contents
取扱説明書・Windows 2000編 LA100-PCI Weslo R 7.2 User's Manual Blitz Extreme Black & Decker TO1160C Use & Care Manual ASPECTS PRATIQUES DU METIER DE MUSICIEN 1 et 2 cycles Aloe Sunscreen - Forever Living Rooster-G8.0 for NetSpart(SC-RS810G-NS)取扱説明書 Oracle Audio Technologies E10898-02 User's Manual Frequency Inverter FA-1L/FA-3H Tripp Lite SmartOnline BP240V7RT3U User's Manual Copyright © All rights reserved.