1. 50 180 210 240 270 300 330 360 390 420 Time min The performance levels are given as representative examples Automated operation throughout heat treatment process OG Safety devices High performance model MT An automatic damper is provided as Electrical compartment cover switch standard for automation in all processes Door switch from temperature heat up to heat treatment Thermal fuse and temperature pull down To reduce pull Air circulator themal switch down time an optional external atmosphere Heater wiring breaker introducing blower forces air into the Upper and lower temperature limit chamber to supple ment cooling alarm function built inside temperature controller Ovenheat protector Cartridge fuse e Specimen power supply control terminal High level of cleanliness during temperature heat up and pull down High performance model The high performance model delivers dedicated cleanliness throughout wide temperature ranges by employing HEPA filters which provide stable filtering even during temperature changes above 150C Useful for heat treatment in liquid crystal production lines Total safety design The temperature controller automati cally prevents the temperature rising by 10C above the set temperature and includes a warning function for user defined upper and lower temperature limits The chamber also features an independent device for preventing abnormal temperature increases
2. If a malfunction occurs an alarm number is displayed on the instrumentation panel and a warning buzzer sounds Two types of program instrumentation to suit different applications Standard Instrumentation and M Instrumentation E dms a L 3 U gt C Standard Instrumentation features programmed operation with operational settings such as constant mode and automatic start stop Suitable for heat treatment drying and similar production line applications Suitable for a range of applications from temperature characteristics testing to heat treatment and drying Programmed operation now allows storing ten patterns each up to twenty steps Provides a wide range of functions including temperature ramp settings and a maximum of 999 repeat cycles 2 Eas S dis 5la Employs interactive settings for ease of O Constant operation mode use Text can be displayed and entered in Japanese or English alphanumeric 9 3 9 characters Three optional functions namely automatic damper integrating hour meter and calendar timer can be included in the instrumentation These functions can be set by using main panel instrumentation keys l Alarm Also available with three communication interfaces RS 485 GPIB and RS 232C Control operation Example of programmed operation Instrumentation Specifications M Instrumentation Constant operation programmed operation and remote operation through c
3. Quality is more than a word v C Dag ult EEN av whe il uw pag DD LE H pa pug qi A Os oe wiley D 3P e op 5 N o gt N oe L 9 z lt x 9 Ideal for heat treatment requiring air condition of Class 5 cleanliness The high cleanliness is assure the temperature heat up and p z Rd AWE tva ESPEC s Clean Ovens are used extensively for E uu drying components in stringent clean air requirements of Class 5 cleanliness T7 e AD nNiaan t ERN AS 5 Ti A space saving upright design and a large LE are some of the user friendly features Eight models to choose from including high performance models which ensure automated operation and dedicat even throughout temperature heat up or cooling procedures n l n PVHC 232 PVHC 212 Bu b i k P d a mz a t E rs z LI usa 7 7 z L T di L uM k um KENE a _ Fan Heater HEPA filter Door Class 5 cleanliness level Class 5 cleanliness level is achieved by employing HEPA filters and a back to front horizontal laminar circulation system which produces uniform high temperature airflow Distance of airflow in the chamber is shortened resulting in smooth air deli very in between specimens and uniform heat treatment Ad
4. ditionally it prevents dust generated from specimens placed upstream from flowing downstream The upright design with instru mentation heater and other mecha nisms gathered on the upper side saves installation space 9 Airtight structure ensures zero contamination All internal seams are welded to create an airtight structure This prevents leakage of insulation materials from joints which would lead to chamber contamination Vibration is also eliminated from affecting the specimens Installation in a clean room Any dust generated by the oven mecha nism is expelled via exhaust duct to prevent accidental infiltration into the clean room optional please be prepared with your own exhaust duct The exterior material of the chamber can also be exchanged with an optional stainless steel material 9 Highly precise non oxidative environment Heat treatment and temperature chara cteristic tests in any desired non oxidized environment are possible thanks to an O concentration indication adjuster with oxygen sensor optional and an N gas injector optional Performance 9 Cleanliness during programmed operation eo 8 Damper fully opened Damper fully opened Eb 300 o Measured value during o programmed operation o 200 e 5E 63 os Cleanliness of SE PVHC 232M 100 9 Clean Oven B md PVHC 232MS MENU VT e DE High Performance E on Clean Oven S de aS 0 c s 0 30 60 90 120 1
5. hed heater Air circulator Stainless steel sirocco fan MES TEM Circulation Ventilation 4 Damper Circulation Ventilation manual switching automatic switching Fittinas Power cable approx 2m from chamber Specimen power supply control terminal g Clean meter for indicating filter service life Cable port 25mm 1 on the left side with cap vede dimensions 580x530x580 5801130580 800X1130X750 580x530x580 580X1130X580 8001130750 580x 1130x530 800 1130x700 Wand Eu ees T70X1280x1025 770x1880x1025 103018801210 77012801025 770x1880x1025 103018801210 770x 18801025 1090X 1880X 1210 Inside capacity L 178 380 678 178 380 678 347 633 Weight kg 220 300 400 220 300 400 300 400 1 PV H C 211 231 331 Based on no load circulation operation at 20 C ambient temperature PVHC 231MS 331MS Based on no load circulation operation at 20 C ambient temperature in class 6 clean room Conforms to Japan Testing Machinery standard K05 2000 2 Indicated cleanliness levels are compliant with JIS B9920 2002 equivalent to FED STD 209D Class 100 However with the doors open a cleanliness level of class 5 cannot be maintained 3 Indicated cleanliness levels are compliant with JIS B9920 2002 equivalent to FED STD 209D Class 1000 4 PVC and PVHC can be provided without a damper 5 Excluding protrusions EET OEE e Leakage breaker e Shelves stainless steel wire Mele MM MEME MEME Electrical compartment cover switch e Shelf bracket sta
6. inless steel plate 2 sets e e Door switch e Cartridge UI EDI LITTLE 2 e Thermal fuse User s tsnusleeeeeeee etr tte tente tette 1 set Air circulator themal switch Heater wiring breaker Upper and lower temperature limit alarm function built inside temperature controller Ovenheat protector N e Do not use specimens which are explosive or inflammable or which contain such substances To do so could be hazardous as this may lead to fire or explosion Cartridge fuse DANGER Specimen power supply Do not place corrosive materials in the chamber If corrosive substances or humidifying water is used the life of the unit may be significantly shortened control terminal A Be sure to read the user s manual before operation CAUTION OPTIONS Modification for clean room compatibility Prevention of particle and dust scat tering from control console and heater vents Flange diameter 87mm Air discharge system Forced discharge Exhaust volume Approx 5m min Please be prepared with your own facility for exhaust fan Pre filter Removes large particles from external air Recommended when installing the oven in a location other than a clean room for oven with damper Where located Air intake on rear of chamber Automatic damper Automatically provides ventilation according to the open close pattern determined by programmed operation Standard on PVHC 232MS 332MS Damper openi
7. memory card 128MB Language support ENG JPN Temperature recorder Temp range 0 to 200 0to 300C 0to 400C Recording system Pen recorder 1 pen or multi point recorder 6 dots Temperature recorder terminal Outputs chamber temperature through thermocouple type K JIS C 1602 Where located Rear of electrical compartment Time up output signal Outputs contact signals at the end of programmed operation Power supply capacity 250V AC 1A Action Outputs close contact output after time up Where located Right side of chamber L ae D Calendar timer Automatically starts and stops chamber operation Setting range sunday to Saturday Possible to set multiple days 0 00 to 23 59 Setting resolution 1 minute Margin of error per month 1 minute Integrating hour meter Displays cumulative chamber operation time Available with or without reset feature Operating time is not accumulated when operation is stopped due to malfunction or for other reasons Measuring time 999 999 hr OPTIONS Mesh shelf For testing small specimens Material 18 8 Cr Ni stainless steel 5 wire 0 8 5 mesh Uniformly distributed load Load resistant shelf and shelf bracket Used to test specimens exceeding weight of the maximum allowable for standard shelves Material 18 8 Cr Ni stainless steel plate Total allowable shelf load Max 200kg Shelf and shelf bracket Equivalent t
8. ng and closing range 0 to 99 Setting resolution 1 Exhaust port flange Flange for discharging hot air from the oven Installed on rear of chamber for oven with damper Material Cold rolled steel plate Unichrome plated finish Dimensions External diameter 87mm Where located Rear of chamber When connecting to exhaust duct the length of duct must be less than 4m Exhaust duct Discharges hot air towards the ceiling for oven with damper Diameter dimension 87mm Where located Rear of chamber Exhaust port flange is located at end of exhaust duct O2 concentration indication adjuster This controls the oxygen concen tration inside the oven Oxygen concentration range 599 1596 oxygen concentration v v Without damper Injection gas N2 gas Normal temperature dry gas Except PVHC 232MS 332MS Nitrogen gas injector Used for reducing specimen oxidation and saving temperature pull down time Input pressure 0 05MPa max flow rate 30L min 0 10MPa max flow rate 100L min 0 20MPa max flow rate 200L min Flow meter Floating flow meter Photo shows max flow rate 30L min OPTIONS Paperless recorder Records temperature inside the chamber Additional inputs may also be recorded Temperature range 0 to 200C 0 to 300C 0to 400C Number of inputs Temperature 1 5 more channels can be turned ON Data saving cycle 5 sec External recording media CF
9. o those supplied as accessories Stand Exterior Cold rolled and rust proof steel plate with melamine baked finish for PV H C 212 gt Outside dimension a MCV 23C 26C are equipped with casters with adjusters Also equipped with door Fixture for securiug body Used to bolt the chamber to the floor Caster Installed on main unit stand With level adjuster Free wheel 4 casters Emergency stop switch Operation is shut down in case of emergency External alarm terminal Outputs alarm signals Output point 1 point Power supply capacity 250V AC 1A Contact output at close in an emergency Where located Right side Communication functions Computer interface e RS 485 GPIB e RS 232C Power cable If the standard 2m is not long enough 5m and 10m cables are available lll Some photographs listed in this catalog contain Japanese display 10
10. ommunication interface Temperature Temperature 0 to 210 C PVC 0 to 210 C PVC 32 to 410 F 32 to 410 F 0 to 360 C PVHC 0 to 310 C PVHC MS T32 to 4 600 amp T3210 T 590 0 to 360 C PVHC Ei de TOSS Time O to 9999 hours 59 minutes Temperature 1 C Time 1 minute One pattern tow steps 10 patterns 20 steps program entry is possible program entry is possible Ramp setting Step or ramp temperature changes possible OFF mode The oven can be turned off during programmed operation Automatic start Timed start up is possible by setting the first step to O C i e oven OFF Automatic stop Timed termination is possible by setting the oven to turn OFF upon completion of a program Completion The operating status upon completion of a program can be set to HOLD CONST or OFF Repetition Up to 999 times 2 CONST 3 OFF Temp Temp END E E GUEST e s Time Time Time Temperature at Operation at Oven is the final step is preset constant turned OFF maintained temperature Input burnout detection function Upper and lower temperature limit alarm function Upper deviation limit temperature function Buzzer alarm function Automatic overheat prevention function Fault indication function Alarm indication function Self diagnosis function Guarantee soak function Select power failure recovery operation function Power failure protection function Quick timer function Quick o
11. peration function x The number of repetitions of a program can be preset between 1 and 999 Stepwise damper setting is possible optional automatic damper required for PVC PVHC Guarantee soak function can be set whereby the timer is activated upon achieving set temperature SPECIFICATIONS Model PVC 212 Pvc 232 PVC 332 PVHC 212 PVHC 232 PVHC 332 PVHC 232MS PVHC 332MS System Back to front horizontal laminar circulation system Power supply 200 220 230V AC 3 3W 50 60Hz 380V AC 3 AW 50 60Hz Max power consumption kVA 4 1 6 4 7 0 4 1 6 8 9 0 6 8 9 0 Ambient operating conditions Temperature 0 to 40 C Humidity to 75 rh Temperature range Ambient temp 60 C to 200 C Ambient temp 60 C to 350 C Ambient temp 60 C to 300 C Temperature constancy TOSC a Temperature 1 5 C at 100 C 1 5 C at 100 2 0T at 2000 F E a pe z uniformity 2 0C at 200C t40C at 9000 250 C al 350 C 40 at 300 Temperature Ambient temp to 200 C Ambient temp to 350 C Ambient temp to 300 C e heat up time within 60 min within 90 min within 80 min At stable temp Class 5 At stable temp Class 5 Cleanliness T At temp change Class 6 3 Particle size 0pm Particle size 0 5um s Exterior matterial Painted steel Melamine resin coating eo Interior material Stainless steel plate S Insulation material Glass wool Filter Heat resistant HEPA filter High temperature HEPA filter Heater Sheat
Download Pdf Manuals
Related Search
Related Contents
Mode d`emploi - Machines à Coudre Tecumseh AEA1343AXA Performance Data Sheet Bedanl dt Marco Swiss TS Edition V2 06-2010 Betriebsanleitung LorchNet Connector Kanex DVSP2HD video splitter クラウドロガー 取扱説明書 9 PSEN op2H-s-30-XXX/1 OPERATION MANUAL Philips EasyStar Adapter CRP758 Copyright © All rights reserved.