Home
X O X O
Contents
1. Tighten the joint screw to the right pushing it as below Push the head part upward carefully 6 Put the result sheets in the printer AN For insertion direction of result sheets please refer to your printer manual as they may vary 7 Remove the PVC cover from the hand and foot electrodes Z From the front view it should be slightly tilted backward 4 Balance the InBody230 Level the InBody230 using the indicator and the four supporters The level indicator is located at the upper left corner of the base frame Four supporters on the bottom of the base frame also work as leveling screws Level Indicator lt Un leveled state gt lt Leveled state gt lt Raising gt lt Lowering gt AN Be careful with handling those screws Your fingers may get hurt on the edge of the base frame 5 Set up connections 2 USB HosT USB SLAVE PRINTER STORAGE COMPUTER HED t t _A Adapter cable 9 pin serial port Thermal printer optional USB HOST port Printer AN ONLY use the adapter provided by Biospace to connect with the powerport Insert the adapter cable tightly into the power input port 8 Turn on the power switch The power switch is located at the rear of the equipment Please turn on the equipment SOM usB Host U
2. InBody230 Quick Installation Guide Contents of the Box When opening the box make sure all the following items are inside A Product Units InBody230 unit 2 Quick installation guide InBody230 Poster 1EA User s manual CD Power Adapter 12V 3 5A 1EA Power cord AC 250V 10A 1 8m 1EA Result Sheet Optional Thermal Printer Optional SD400 Optional Ch Installation Instructions A Workplace Requirements 1 Indoor installation is highly recommended Any outdoor installation places should meet all the conditions below 2 Operation conditions 10 c 40 c 50 F 104 F 30 80 RH 500 1060hPa 3 Adapter Power Input AC 100 240V 50 60 Hz 1 2A Power Output DC 12V 3 5A B Attention Please READ the following CAREFULLY before installing the InBody230 1 The InBody230 should be placed horizontal to the ground 2 DO NOT hold the head part with LCD or joints of hand electrodes when moving the InBody230 Workplace Requirements Right posture for moving lt Inclined place gt lt Flat level gt lt Wrong posture gt lt Correct posture gt 1 Open the box and remove the top pad Result Sheet Top Pad 3 Unfold the InBody230 Pull the stand of the equipment upward carefully until it stands upright
3. section 3 Personal Profile of the manual CD C Try again after wiping hands and feet If this message still display on the LCD after checking the subject s posture on the second trial a subjects soles and palms are too dry to be measured precisely In this case a subject should wipe his her soles and palms with wet tissue and try again Manufacturer s Warranty 1 BIOSPACE guarantees that the product has been approved through qualified test procedures under severe conditions 2 The two years of manufacture s warranty begins on the date of purchase 3 During two years of warranty period BIOSPACE remedies any original defect in material or workmanship 4 The following defects or malfunctions will not be covered under the two years of warranty a Any defect caused by user s fault b Any defect or damage caused by not following the instructions described in the users manual c Any defect or damage caused by natural disasters storm flood earthquake etc d Any defect or damage caused by disassembly of the InBody230 or by modifying internal parts or program by unauthorized personnel 5 An extended warranty may be purchased by executing an extended warranty contract after the initial warranty period 6 No return is allowed after a product is opened The proof of purchase must be accompanied before requesting service 7 Please contact authorized personnel for any service calls The client s c
4. Ibs or range 5 kg 5 kg step 0 1 kg 3 Result Sheet Mode Printed Select when using the printed result sheet provided by Biospace Built in Select when using general A4 paper 4 Number of result sheets Select the number of result sheet to be printed 0 1 or 2 5 Volume Adjust the volume of the sound 0 8 4 Data Transfer If you input an ID of personal information the data is automatically saved You can easily transfer all data stored in the InBody230 into a USB storage device 1 Turn off the InBody230 2 Connect a USB storage device to the USB host port Please use the only USB storage device provided by Biospace only Contact Biospace or an authorized distributor if you need further information of USB soe Storage devices compatible with the InBody230 3 Tum on the InBody 230 4 Press the ENTER button after finishing the warming up process 5 Saving message appears Not found USB storage message appears when the USB storage device is not connected Lack of memory space message appears when there is not enough space to store in the USB storage device 6 Complete message appears when it is finished transferring all the data InBody230 Maintenance 1 After usage wipe electrodes with a wet tissue also known as wet naps surface wipes anti bacterial tissues etc Wet tissues can be purchased at any local stores 2 Handle the arms with care Never apply e
5. C Software Select when you use LookinBody Enable Disable 2 COM1 Serial Select the external device to be connected to the 9 pin serial port Disable Do not use the 9 pin serial port SD400 Select when you use SD400 4 devices at the most can be used with port 1 port 4 Lookin Body Select when you use Lookin Body with 9 pin serial port Thermal Printer Select when you use a Thermal Printer Please reboot InBody230 when you connect a new extemal device NOTE 3 Quick Setup Users can easily modify frequently used functions in the initial screen FFF AcE ER c cana 8 8 feicm o ANALYSIS Under Normal Over BMI SMM FAT WHR A How to modify using Quick Setup 1 Press the MODE button at the initial screen and the quick setup screen will appear as above 2 Choose an item you want to modify Use the left and right buttons 4 to move into the category that you want to change Use the upper and lower buttons a w to modify setup values 3 Press the ENTER button to save the changes and press the EXIT button to go back to the initial screen B Quick Setup Menu 1 Unit Select the unit to be used in measurement kg cm kg in Ib cm Ib in 2 Adjust Weight If weight adjustment is needed due to clothes or accessories select desired offset values Use the upper and lower buttons 4 w to adjust the weight Calibration range 10 Ibs 10 Ibs step 0 1
6. SB SLAVE PRINTER STORAGE COMPUTER Power Switch When connecting peripherals printers and other optional devices to InBody230 turn on the power of peripherals before turning on the InBody230 When turning the power off turn off the InBody230 before turning off the peripherals This process will minimize the harm to the equipment caused by electric shock 9 Self calibration When the power is turned on there is a signal sound and as the logo comes up on the screen self calibration starts automatically InB o dy Self calibration will last about 15 seconds After self calibration there is another signal sound and the InBody230 is ready for the measurement DO NOT touch the base frame after turning it on and during warming up During ama Warming up the InBody230 processes the self testing zero point setup for the scale and adjustment of the internal circuit Applying pressure or weight to the base frame during self calibration will result in an inaccurate calibration and the measurement may be inaccurate 10 Measurement Confirm the InBody230 is ready for measurement If it is ready the following screen is displayed For accurate results please take off heavy clothes and accessories NEVER use this equipment if you have ewer Medical electronic implants such as pacemakers Electronic life support systems such as an artificial heart lung Portable electr
7. n off the power switch and unplug the power cable before repacking Avoid any severe physical shock jarring or other damages to the device while repacking especially the arms and foot electrodes 1 Turn off the power switch 2 Remove all cables connected to the InBody230 If a thermal printer is attached to the unit remove the thermal printer first 3 Raise the hand electrodes and make parallel with the equipment s head 4 Step onto the foot board and slowly fold the head part with hand electrodes till it reaches to the back of the equipment 5 Loosen the joint screw to the left 6 Fold the head and stand towards the foot board For the InBody box users 7 Put the equipment in the box Place the pads in position as illustrated below 8 Seal the box with a tape For the InBody bag users 7 Put the equipment in the bag as illustrated below InBody230 SETUP MENU The setup allows you to customize several functions through modification The below setup screen appears as pressing the SETUP button on the keypad at the initial screen The setup of the InBody230 consists of 5 items Region Printer Result Others and Interface Printer Result 4 Others Interface Set Date 2007 7 09 05 WED Set Time 13 11 12 Display Mode yy mm dd Unit kg cm Language English Ethnic ss Background Asian 1 How to Modify Settings 1 Use the left and right bu
8. onic medical devices such as an electrocardiograph A This equipment may cause malfunctions of the above mentioned medical electronic devices Step on the base frame and measure weight Make sure to place your heels on the circular electrodes and the front soles on the fore foot electrodes When you steps onto the machine the screen will display your weight Bare feet must be in contact with the foot electrodes Fingers and thumbs must be touching z hand electrodes Enter personal information and press ENTER When the cursor is at the I D use the keypad beneath the screen type the D AGE HEIGHT and GENDER WEIGHT will be automatically appeared on the screen Please press ENTER to start the measurement ID SKM00079 0008 Hold the hand electrodes properly Measurement will begin and the figures for proper posture will appear on the screen The proper body posture is the standing upright position with arms and legs extended A During the measurement maintain the same posture and w do not move or talk The measurement takes approximately 30 seconds When the measurement is completed the The printer connected to the InBody230 Completion message appears on the automatically prints out the results screen with a signal sound Return each Then the InBody230 goes back to the hand electrode back to its original position initial screen and step d
9. opy of the manufacture s warranty is located at the last page of user s manual CD InBodyz230
10. own from the base frame BIOSPACE 1996 2007 Biospace Co Ltd All rights reserved Notice The information contained herein is subject to change without notice No part of this manual shall be reproduced stored in any retrieval system or transmitted by any means electronic mechanical photocopying recording or otherwise without written permission from Biospace No patent liability is assumed with respect to the use of the information contained herein Biospace is not liable for any damage caused by a failure to meet the requirements in this user s manual Biospace Co Ltd 518 10 Dogok 2 dong Gangnam gu Seoul 135 854 KOREA Tel 82 2 501 3939 Fax 82 2 501 3978 Homepage http www biospace co kr E mail biospace biospace co kr Biospace InBody and Lookin Body are the registered trademarks of Biospace Co Ltd The names of the companies and products in this manual other than those of Biospace Co Ltd are the trademarks of the companies Stating the products of other companies is strictly for the purpose of providing information and not to guarantee or recommend the products Biospace is not responsible for the performance or the use of these products Biospace reserves the right to modify the dimensions or exterior of InBody230 to improve the quality of the products without consent of the customer www biospaceamerica com Repacking Be sure to tur
11. r you must contact a local distributor of Biospace Text To be selected when a keypad is used to directly type in a logo When you press the ENTER button a screen for the logo upload will appear A text of logo must be created with alphabets and numbers only 5 I D Manual You can enter the ID If you put in an ID the data is automatically saved in the InBody230 Auto GUEST automatically appears on the ID section The InBody230 will not save any data under this condition D Others 1 Measure Weight Enable The InBody230 measures weight when an examinee stands on the foot frame Disable The InBody230 does not measure weight and weight needs to be entered manually like other personal information 2 Adjust Weight It is possible to adjust weight offset value If weight adjustment is needed due to clothes or accessories use the upper and lower buttons a v to select the desired offset value Calibration range 10 Ibs 10 Ibs step 0 1 Ibs or range 5 kg 5 kg step 0 1 kg 3 Volume Adjust the volume of the sound 0 8 4 Sound BEEP Use Beep sound to inform measurement status OFF Do not use any sound during the measurement 5 Initialize History Use to erase the entire saved data Press the ENTER button to delete all data 6 Version The current program version is displayed E Interface Setup the external devices to connect with the InBody230 through a network 1 Lookin Body P
12. ttons 4 gt or number buttons to select a category among Region Printer Result Others and Interface Then selected item s subcategories are displayed on the screen 2 Use the upper and lower buttons a v to move to the subcategories 3 Use the right button to select the category and press the ENTER button to move into the options Press the upper and lower buttons a v to modify the option you select 4 Use the left button 4 or the EXIT button to move out from that category 5 Use the upper button a or number buttons to go into other categories Region Printer Result Others or Interface 6 Use the EXIT button to finish the setup menu 7 It will be automatically saved as you move out from the setup menu 2 Setup Menu A Region Set the Date Time Display Unit Language and Ethnic Background 1 Set Date Set the date using the upper and lower buttons a v to modify the date Use the left and right buttons 4 or the ENTER button to move to Year Month and Date 2 Set Time Set the current time using the upper and lower buttons a w to modify the time Use the left and right buttons 4 or the ENTER button to move to hour minute and second 3 Display Mode Select a time display mode yy mm dd mm dd yy dd mm yy 4 Unit Select the unit to be used for height and weight kg cm kg in Ib cm Ib in 5 Language Select the language to be used 6 Ethnic backgro
13. und Select the ethnic background of the examinee Asian Caucasian African Hispanic Others B Printer 1 Printer Printers that support PCL3 or above and GDI SPL are compatible with InBody230 2 Alignment Use the direction buttons a v lt gt to adjust the printing position After adjusting you can check whether the alignment has been set properly or not by Test Print Alignment range X left right Y up down 50 50 3 Test Print Check the printing position by printing out a sample result sheet 4 Thermal Printer Enable Enable is checked if the thermal printer is selected from E Interface For a test print move the cursor to Enable and press Print button Disable Disable is checked when the thermal printer is not in use C Result 1 Mode Printed To use printed result sheet provided by BIOSPACE Built in To use plain A4 paper All formats of the result sheet will be printed out 2 Number of Result Sheets Printing You can decide the number of sheets to be printed 0 1 or 2 If None is selected it will not print the result sheet 3 BMI Standard Select the standard range for BMI Asian The standard range is 18 5 23 0kg m WHO The standard range is 18 5 25 0 kg m 4 Logo Type Select a logo to be printed on the result sheet Picture To be selected when a computer is used to upgrade a logo In this case as it cannot be uploaded by a use
14. xcessive stress near the hand electrode joint The damage caused by misuse may affect the function of the internal cable and electric board 3 Do not place anything on the base frame nor apply any pressure onto it when the InBody230 is not in use 4 When the InBody230 is not in use for a period longer than a day unplug the adapter 5 Do not move or relocate the InBody230 while the power is on 6 Do not drop food or drinks on the equipment They may affect the electrical parts in the equipment or cause damage 7 Once a week wipe the exterior sides of InBody230 with a dry towel In particular clean the LCD monitor softly with care not to scratch the surface 8 Follow local governing ordinances and recycling plans regarding disposal or recycling of device components Error Messages The InBody230 displays an error message to alert the operator of problems and to recommend the correct action A Remove any objects on the footboard When pressure or weight is applied to the base frame during self calibration this message appears Turn the InBody230 off and on again after removing the obejects from the base frame Please do not apply pressure or weight to the base frame during self calibration B Enter the personal data again If entered subject data are beyond acceptable ranges this error message appears When inputting subject data do not exceed the acceptable ranges of Age and Height please refer to Chapter2
Download Pdf Manuals
Related Search
Related Contents
Submersible Utility Pumps Pompes utilité submersibles VD710 : Manuel d`installation et de référence Taxe de séjour Manual Samsung ML-1710 Manual de Usuario Untitled - Lidl Service Website etre doue pour les langues :approches scientifiques et Trigger Box User`s Manual 119 Copyright © All rights reserved.
Failed to retrieve file