Home
        Scienceware Extra-large Desiccator Manual PDF - Cole
         Contents
1.  23 South  Wayne  NJ 07470  TEL  1 800 4BEL ART e   FAX  973 694 7199 e www belart com    Scienceware   is a registered TM of Bel Art Products  i  Bel Art Products assumes no obligation or liability for any advice furnished by it  or for results ay  obtained with respect to these products  All such advice is given and accepted at the buyer   s risk  3 LA e       2012 Bel Art Products  All Rights Reserved  Maat    INSTRUCTIONS    Scienceware   Grande Desiccators    STANDARD CATALOG NUMBER F43000 1010  AUTOMATIC CATALOG NUMBER F43020 1010  GAS PURGE CATALOG NUMBER F43010 1010  SHELVES CATALOG NUMBER F43000 0001       PRINCIPLES OF OPERATION  Each of the three Scienceware   Grande Desiccator maintains a desiccated  environment in a specific manner     Standard  F43000 1010  requires a user supplied desiccant   Bel Art Products  recommends the color indicating  rechargeable desiccant catalog number  F42045 0250  Desiccant in a Cartridge   Instructions for installation are  provided below           Automatic  F43020 1010  utilizes the Scienceware   Auto Desiccator Module to  automatically and continually regenerate the color indicating silica gel desiccant   providing worry free desiccation  Instructions for installation are provided below     Gas Purge  F43010 1010  is supplied with pre drilled holes on the back panel  and two gas port fittings with stop cock valves  Instructions for installation are  provided below         NOTE  Do not use concentrated acids as desiccants  Do no
2. CARE AND CLEANING   Correct care of your SCIENCEWARE   GRANDE DESICCATORS will maintain their  appearance  utility  and life  Do not use abrasive cleansers which will leave  scratches  We recommend the use of Bel Art Products    Aquet    Detergent  Cat  No   F17094 0020 or F17094 0030     Every joint on these desiccators was factory sealed with high quality silicon seals and  the bolts were all tightened at the factory to exacting standards  Do not loosen any  bolts  doing so will void the warranty  Inspect bolts for tightness at least 2 times per  year  Gently Hand tighten if needed Over tightening can cause damage to the unit     IMPORTANT INFORMATION   CAUTIONS for all Scienceware   Grande Desiccators    e Do not place in front of a heating or air conditioning duct   e Do not place near a heating device   e Do not place in direct sunlight   e Do not place in areas with smoke or steam   e Do not attempt to introduce vacuum inside the cabinet   e Do not attempt to introduce pressure in excess of 1 to 2 psi inside the cabinet  e Do not place any explosive or hazardous chemicals in the cabinets  e Do not autoclave   e Do not expose to organic solvents or concentrated acids   e Indoor use only   e Use only within ambient temperature range of 5   C to 40  C    The user should be aware that if the equipment is used in a manner not specified by  the manufacturer  the protection provided by the equipment may be impaired        Bel art Products  943001015     03 12    T    661 Route
3. ove  it from its packaging  Locate the electrical cord extending from the desiccator  With  the transformer UNPLUGGED from the power source  fully insert each of the two  terminals  located at the end of the electric cord  under each of the screw covers on the  transformer  one terminal per screw cover   The Scienceware   Auto Desiccator  Module is not polarized so either terminal can be attached to either screw  Fasten  the terminals to the transformer by tightening the screws with a screwdriver  Plug the  transformer into a properly functioning 120VAC electrical outlet  The internal green  light inside the Scienceware   Auto Desiccator Module glows indicating the unit is  in operation  Once plugged in  the dehumidifying cycle will start immediately and  the cabinet   s moisture will be absorbed by the silica gel beads contained within the  Scienceware   Auto Desiccator Module  This will be followed by a brief heating cycle  within the electric unit and then by a discharge cycle when the moisture is released  to the external atmosphere  Initially the cabinet should be left closed for  approximately 8 hours to bring the relative humidity reading down into the 25   range  The Scienceware   Auto Desiccator Module contains four air flow ports that are  opened and shut by flapper valves  These valves were carefully aligned during factory  installation to ensure proper function  DO NOT tamper with or pull on the valves  Close  door and secure both top and bottom latches with a   t
4. stopcock   When it is felt that a sufficient exchange  has been made  close the entry stop   cock first then close the exit stopcock   This will avoid pressure build up in the  cabinet        Shelving  Two shelves are supplied with every Scienceware   Grande Desiccator   Additional shelves  2 per pack  can be purchased as desired under Bel Art Products  Cat  No  F43000 0001  Each shelf will support a maximum of 10 lbs  Shelves can  be repositioned as desired to rest upon any of the epoxy coated wire rail supports  except the top rail  Shelves are designed to slide back and forth and will extend  forward approximately half the depth of the shelf  Under shelf guides prevent side  to side motion and tall tail edges prevent accidental forward tipping of the shelf   To remove a shelf  slide the shelf forward and lift the front edge as needed so that  the under shelf guides  both front and rear  can pass over the wire rail supports     SPECIFICATIONS  CATALOG NO  F43000 1010  F43010 1010  and F43020 1010    Overall External Dims  26    x 26    x 24     W x H x D   Construction Materials  Body   Clear Polycarbonate  Construction Materials  Shelves   Clear Acrylic    Construction Materials  Door   Clear Polycarbonate    
5. t expose the desiccator  to organic solvents as these materials may attack the clear polycarbonate   material and cause crazing  hairline cracking   Such crazing could eventually  weaken the desiccator walls  Should you have any questions or problems with   the desiccators  please contact Bel Art Products Technical Support for help     INSTRUCTIONS FOR ASSEMBLY AND USE   Standard  F43000 1010   No assembly is required  Remove desiccator from the  box and remove the packaging materials from around the shelves  inside the unit    Place the desiccator on a flat horizontal surface  leaving room in front for the door  to swing open  Place a desiccant of your choice   Bel Art Products recommends the  color indicating  rechargeable desiccant catalog number F42045 0250  Desiccant in  a Cartridge  in the space below the bottom shelf  Close door and secure both top and  bottom latches with a   turn clockwise           Automatic  F43020 1010   Installation of the Scienceware   Grande Auto   Desiccator is fast and easy  Remove desiccator from the box and remove the packaging  materials from around the shelves  inside the unit   Place the desiccator on a flat  horizontal surface  leaving room in front for the door to swing open  When placing  the left side of the cabinet near a wall  be sure to leave several inches to ensure that  Scienceware   Auto Desiccator Module has room for proper venting  Next  connect  the electrical cord to the supplied transformer  Locate the transformer and rem
6. urn clockwise        Gas Purge  F43010 1010   Place the desiccator on a flat horizontal surface  leaving  room in front for the door to swing open  Locate the two pre drilled holes on the back  of the desiccator  Referring to the illustration  slip one of the O rings  Item 2  over the  threaded end of the stopcock  Item 1   Insert the threaded end of the stopcock into  one of the holes in the cabinet from the outside  Holding the stopcock in place with  one hand screw the nut  Item 3  onto the threaded end by inserting your hand through  the open door and hand tighten it  Using a 5 8    socket wrench  tighten the nut so the  O ring seats  Repeat the process with the second stopcock  Close door and secure  both top and bottom latches with a   turn clockwise     Parts list     Item 1 Stopcock  2   Item 2 O ring  2   Item 3 Nut  2     The gas ports permit creation of a gas   specific atmosphere  The cabinet is not  designed to withstand negative pressure  and there is a high danger of implosion  if a vacuum line is connected  Similarly   high pressure gas entry is not advised  as this may rupture the cabinet  If Carbon  Dioxide  Nitrogen or other gas is to be  introduced  make sure that both  stopcocks are open  If the gas is  heavier than air  the inlet source  should be connected to the lower  stopcock  if the gas is lighter than air   connect the inlet source to the upper  stopcock  The gas should enter at a  pressure of one to two psi to sweep  out the air through the other 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
PA/VDA BOXTM  分銅管理システム 株式会社 村上衡器製作所  RD4OOOTL - The Hireman  Teclado para dispositivos PTZ de red ACCKBD320  contexte et culture en enseignement du fls    Prévenir les brûlures  dreamGEAR DGDXL-2682 game console accessory  APC InRow  R4/R6 - Promise Technology, Inc.    Copyright © All rights reserved. 
   Failed to retrieve file