Home
calodia & hawai aluminium radiator ranges with
Contents
1. Manufacturers of Thermo Dynamic Electric Radiators Towel Rails amp Wireless Programming 7 Lundy Court Rougham Industrial Estate Bury St Edmunds Suffolk IP30 9ND Www kalirel co uk Email contactuk kalirel com Tel 01359 272551 Fax 01359 271625
2. Thermo dynamic fluid filled electric radiators with electronic thermostat JIN CALODIA amp HAWAI RADIATOR RANGES WITH CLASSIC STYLE THERMOSTAT rl A INSTALLATION anp Location Installation Connection Safety Use You have just acquired one or several of our electric radiators Thank you for having chosen Kalirel and for your trust in our products For your comfort and safety we invite you to read the manual instructions and the advices carefully If you have any technical questions and requirements www kalirel com www kalirel co uk INSTALLATION AND WIRING INSTRUCTIONS PAGE Electrical installation c c0eccceesseeeeeees 3 Installation rules in wet rooms 3 Electrical CONNECTIONS ssssseseeseseeeseees 49 Starting ecscscecesescsssesesescsesesescessesceeseecesereees i Safety instructions ccescecsseseseeeeeseneeee j RADIATOR INSTALLATION AND WALL MOUNTING Where to install the radiator 3 9 Wall MOUNTING csesessecessssesesessesesesseseseseeees 5 6 FOR YOUR SAFETY 6 9 IMPORTANT WARNING ELECTRONIC THERMOSTATS CALODIA and HAWAI 7 8 USER S MANUAL CALODIA amp HAWAI ELECTRIC RADIATOR INSTALLATION INSTRUCTIONS E ELECTRICAL INSTALLATION E INSTALLATION RULES ELECTRIC RADIATORS IN THE WET ROOMS kitchens bathrooms 1 The electric installation must be in conformity with the standards and the code of practice curre
3. fuse In case of overheating the fuse melts and cuts the power supply The heating element must then be changed by the manufacturer or by a qualified professional electrician please contact your supplier MAINTENANCE 1 For perfect functioning of your radiator and to ensure its durability it is necessary to clean the radiator at least once a year Cut off the radiator power supply before carrying out its cleaning Clean with a wet cloth and a non aggressive soft product liquid soap for example on the radiator surface without forgetting the back and the lower part and wipe it with a dry rag repeat the operation if necessary Do not to use any product on the thermostat wipe it with a dry rag 2 If you must open the windows to give air switch off the radiators by stopping the thermostat you will save energy WALL MOUNTING BRACKETS 240 mm 320 mm 400 mm 560 mm 640 mm 720 mm 800 mm 960 mm 1040 mm C 5 elements 6 elements 7 elements 9 elements 10 elements 11 elements 12 elements 14 elements 15 elements IMPORTANT FUNCTIONING Light clicks can sometimes be heard They can be explained by the interlocking of certain types of thermostats Light cracks can punctually be heard They can be explained by the expansion of various metals composing the radiator These phenomena are usual and inherent to this type of radiator it is neither a breakdown nor a failure WARNING It is essent
4. ade practice in the coun try where it is fitted The thermostat is class I and protected against water splashes It can be installed in Zone 2 and 3 in bathrooms Do not touch thermostat when in the shower or bath Install a calibrated earth leak circuit breaker in accordance with current norms 3 1 Installation 3 1 1 Where to install it The thermostat must be installed in accordance with the diagram Shelf 2 10cm OK NO gt 10 cm gt 10 em Do not cover the ventilation holes on the thermostat 3 1 2 Connecting to the electric power supply Connect the thermostat s electric wires to the mains power supply using a junction box Place the junction box at least 25cm above the floor Install the junction box behind the thermostat Do not place any plug sockets or plugs bet ween the two 230 V 50 Hz is blue grey ck ote External control see 6 1 The power supply circuit must be sectioned Sectioning must be done using a multi polar device sectioning all the power supply terminals The sectioning distance between the contacts of each terminal must be at least 3mm 3 1 3 Connecting to the external command for load shedding Use the pilot wire Connect the electric wire to the programming base unit fitted with a pilot wire If the pilot wire is not connected to a programming base unit then it must be insulated for safety reasons In no event should it be connected to the earth
5. ial that you keep this user s leaflet with the radiators it refers to for any further consulting If the device were to be resold or transferred to a third party this user s manual must be transferred with the radiator so that the new user can know and follow the manual specifications Failure to comply with the manual instructions will invalidate the manufacturer s warranty CLASSIC ELECTRONIC THERMOSTATS Thermostat with pilot wire User instructions 1 1 Configuration PUSH TO CHANGE MODES AUTOMATIC COMFORT back ground frost protection MODE Mode INDICATOR lights AUTOMATIC COMFORT back ground frost protection Controlling the temperature Slide up amp dawn until you obtain the required temperature HAWAI THERMOSTAT Controlling the temperature Slide round until you obtain the required temperature Ce Mode Selector Dial Comfort Mode operates at Le the temperature set on the dial Background Mode opertates at 3 degrees lower than Indicator Light comfort setting Red Comfort mode Frost Protection Mode maintains 7 C temperature Green Background mode Off No Light Off RCH Y Auto Mode This means that the radiator will operate in comfort or background modes at the times dictated by the external pilot wire programmer 2 1 Safety Instructions The installation must comply with current norms and best tr
6. iator minimum 100 mm maximum 150 mm Distance between the radiator side and the wall angle minimum 100 mm 2 Avoid any obstacle around the radiator 3 In the case of positioning a rack on the top of the radiator you must respect the space of 100 mm between the radiator and the rack 4 Do not install the radiator below one or several socket outlets 5 Do not put any object which can obstruct the air circulation piece of furniture armchair closer to 60 cm of the radiator front Figure 2 E MOUNTING 1 Install the radiator to a wall with the according to the drilling dimensions figure 3 2 Use plugs and screws adapted to the structure of the walls where the radiator will be mount For radiator installation see figure n 4 5 6 7 8 9 Install the radiator horizontally and at evel Metal brackets POSITIONING RADIATOR The radiator must be installed horizontally and at level E gt Figure 3 BRACKETS DRILLING DIMENSIONS FOR If you are supplied with 3 brackets two are to be positioned at the bottom and separated by the distances shown adjacent with the third bracket positioned centrally at the top If you are supplied with 4 brackets then two are to be positioned at the top and two at the bottom separated by the distances shown adjacent FOR YOUR SAFETY In accordance with the regulations the heating element inside the radiator is equipped with an integrated
7. length it should not be extended nor shortened DO NOT twist or jam the cable in the radiator wings behind it If the cable is damaged you risk very serious wounds that could lead to death After its replacement if the assembly was not carried out properly you risk the same wounds If the electric cable is damaged it must be replaced by the manufacturer its after sale service or by people of similar qualification in order to avoid any danger WARNING in order to avoid overheating do not to cover the heating appliance The heating appliance should not be placed just below a socket outlet 3 This heating appliance is filled with an accurate quantity of special fluid Repairs requiring the opening of the fluid tank should only be carried out by the manufacturer or his after sale service which normally should be contacted in the event of fluid leakage 4 When the heating appliance is to be sent to the dump respect the regulations concerning the oil recycling Fluid residues will have to be recycled in a registered facility in conformity with the local regional or national regulations 5 In case of failure or possible repairs contact your supplier RADIATOR INSTALLATION AND WALL MOUNTING E WHERE TO INSTALL THE RADIATOR For the radiator correct operation and the users safety 1 The minimal dimensions indicated on figure 2 will have to be respected Height between the ground and the lower part of the rad
8. ntly used in the country where the product is going to be installed e This radiator is class II with double insulation DD It is IP24 therefore protected from splashed water e It can be installed in bathrooms volume 2 and 2 The radiator electrical connection must be carried out in a standardized junction box In kitchen or bathrooms the connection box should be installed 25 cm above the floor 3 The radiator must be supplied with 230 V 50 Hz single phase and neutral Other power supplies cannot be used 3 provided that no electric the one previously specified control unit can be touched by the people using the 4 Each radiator must be supplied with a dedicated wire bath tub or the shower and protected with a 10 amp circuit breaker for devices It must necessarily be connected to the electrical supply from 500 W to 2000 W of power network in a standardized junction box without the using a socket outlet Earthing is prohibited e The circuits supplying the electrical devices in the wet rooms must necessarily be protected by a 30milli amp Residual Current Device for safe operation E ELECTRICAL WIRING 1 The radiator is class II with dual insulation 2 The radiator is not equipped with an earth wire and it is strictly forbidden to connect it to the ground 3 For thermostats equipped with a pilot wire to be connected to programming systems It is essential to get a correct connec
9. tion of the phase and neutral Colour code see picture 1 BROWN connection with the phase GREY connection with the neutral BLACK connection with the pilot wire if necessary HT CONNECTION Figure 1 Programming system L Phase Brown color L t T N Grey color FP Pilote wire Black color Neutral 4 If the pilot wire is not connected the wire tip must be insulated 5 A The pilot wire direct connection to the power supply phase neutral or earth will destroy the thermostat CAUTION Before any installation or operation on the electrical circuit please cut off the power supply with the circuit breaker or with the main circuit breaker and check if there is live wire E STARTING 1 Check that the radiator is correctly supplied with electricity then test the various functions of the thermostat and set the temperature you want to get 2 In case of faulty operation please check that the radiator is properly supplied with electricity If the radiator is properly supplied and if it does not work correctly please advise your installer or the manufacturer E SAFETY INSTRUCTIONS 1 Do not dismount nor modify the radiator 2 In order to avoid any risk of electrocution Do not take apart the electronic thermostat which has been assembled in the factory Do not introduce a metallic object into the thermostat The electrical cable integrated in the factory is not replaceable delivered in a standard