1. designed to be used in conjunction with Invacare patient lifts Mobile patient lifts are battery powered transfer devices designed to be used in most of the common lifting situations for example Between the bed and a wheelchair e To and from the toilet e Lowering and raising patients to from the floor The mobile patient lift can be used to transfer and position completely or partially immobile patients There are no known contraindications for this product Selecting the appropriate slings and accessories for each individual is important to assure safety when using a patient lift See Invacare s sling and accessory user manuals for further information on those devices Birdie Invacare recommends that the patient be transferred to a shower chair or other means for bathing The mobile patient lift can be turned rotated in place for transfers with limited floor space 1 3 Scope of delivery The items listed in the tables are included in your package Slings and additional hanger bars are sold separately Depending on your model the wall charger may be sold separately Lift piece Battery piece Hand control piece Hanger bar I piece Mains cable piece User Manual 1 piece O o 9 0 0 Manual leg spreader handle piece optional Sling 1 piece optional 1 4 Service Life WARNING N Risk of Falling Maintenance MUST be performed only by
2. press the up arrow button to raise the patient above the surface of the bed The patient should be elevated just high enough to clear the bed with their weight fully supported by the lift When the patient is clear of the bed surface swing their feet off the bed Detail B e After transfer unhook the sling from all attachment points on the lift and remove the sling from around the patient Wheelchair Transfer 1575025 A l WARNING Risk of Injury Before transferring check that the wheelchair weight capacity can withstand the patient s weight The wheelchair wheel locks MUST be in a locked position before lowering the patient into the wheelchair for transport Perform these steps in addition to those in 6 4 Lifting and Transferring the Patient page 26 when transferring to or from a wheelchair 2 Engage the wheel locks of the wheelchair to prevent movement of the wheelchair Position the patient over the seat with their back against the back of the chair Begin to lower the patient With one assistant behind the chair and the other operating the patient lift the assistant behind the chair will pull back on the grab handle on select models or sides of the sling to seat the patient well into the back of the chair This will maintain a good center of balance and prevent the chair from tipping forward o Use the straps or handles on the side and the back of ll the sling to guide the patient s hips
3. unlocked during lifting procedures to allow the patient lift to stabilize itself when the patient is initially lifted from a chair bed or any stationary object Move the lift to the patient area and prepare to lift Refer to 6 2 Preparing to Lift page 23 Attach the sling to the lift Refer to 6 3 Attaching the Slings to the Lift page 25 Perform one of the following e Lower the bed to the lowest position e Lift the patient high enough to clear the stationary object with their weight fully supported by the lift Refer to 5 2 Raising Lowering the Lift page 17 il The boom will stay in position until the DOWN button is pressed 1575025 A WARNING A Risk of Injury An improperly attached sling could cause the patient to fall An improperly adjusted sling could cause injury to the patient Adjustments for safety and comfort should be made before moving the patient Position the patient in the sling as directed by the instructions provided with the sling Use steering handle on the mast at all times to push or pull the patient lift Before moving the patient check again to make sure that e the sling is properly connected to the hooks of the hanger bar the hanger bar is firmly attached to the carabiner the safety catch of the carabiner is closed If any attachments are not properly in place lower the patient back onto the stationary object and correct this problem Using the st
4. all parts for shipping damage before using In case of damage Do not use the equipment Contact the Dealer or Invacare representative for further instructions 2 2 Operating Information This section of the manual contains general safety information about your product For specific safety information refer to the appropriate section of the manual and procedures within that section For instance for safety information related to assembling the lift refer to section 4 Setup page 13 General A WARNING Risk of Falling Do not attempt any transfer without approval of the patient s physician nurse or medical assistant Thoroughly read the instructions in this User Manual observe a trained team of experts perform the lifting procedures and then perform the entire lift procedure several times with proper supervision and a capable individual acting as a patient Use common sense in all lifts Special care must be taken with people with disabilities who cannot cooperate while being lifted Use steering handle on the mast at all times to push or pull the patient lift Be sure to check the sling attachments each time the sling is removed and replaced to ensure that it is properly attached before the patient is removed from a stationary object bed chair or commode WARNING The patient lift can be used indoors or outdoors If the patient lift is used in the area of a shower or bath ensure that the pati
5. be adjusted according to the patient s weight as described below The weight is preset to 75 kg Adjusting the lowering speed for manual emergency lowering I Locate the screw on top of the red emergency grip 2 Loosen the screw to increase the speed 3 Tighten the screw to decrease the speed Birdie 5 6 Charging the battery IMPORTANT e Make sure the emergency stop is not activated Do not use the lift while charging the battery Make sure that charging takes place in a room with good air ventilation Do not use or move the lift without unplugging from the socket outlet after charging Do not attempt to use the lift if the battery housing is damaged Replace a damaged battery housing before further use CB Home control unit The lift is equipped with an internal charger It is recommended to charge the batteries daily to ensure optimal use of the lift and prolong the life of the batteries Furthermore it is recommended to charge the batteries before first use The control unit is equipped with a sound signal which will beep when operating with low battery capacity It is recommended to charge the batteries as soon as the sound signal is heard A Ts Connect the mains cable to the control unit and plug it in 2 Disconnect the charger cable before using the lift again 20 It takes about 4 hours to charge the batteries The charger stops automatically when the batteries are ful
6. powder coated Steel powder coated and foam Actuator housing hand control mast protector casters and other plastic parts material according to marking PA PP PE Bolts and nuts Steel rust protected zinc plated 1575025 A Notes Invacare Sales United Kingdom Invacare Limited Pencoed Technology Park Pencoed Bridgend CF35 5AQ Tel 44 0 1656 776 222 Fax 44 0 1656 776 220 uk invacare com www invacare co uk 1575025 A 2013 11 20 Making Life s E i Possible E FERN EDS See er nage Manufacturer Invacare Lda Rua Estrada Velha 949 4465 784 Leca do Balio Portugal Yes you can
7. qualified personnel Improper assembly may cause injury or damage Regular maintenance of patient lifts and accessories is necessary to assure proper operation DO NOT overtighten the mounting hardware This will damage the mounting bracket The hoist has an expected lifetime of 8 years Actuator Service Life Number of lifts per Service life of actuator day in years Et lo dos Es 1575025 A General Number of lifts per Service life of actuator day in years ESA 1 5 Warranty Information Terms and conditions of the warranty are part of the general terms and conditions particular to the individual countries in which this product is sold Contact information for your local Invacare office is located inside the back cover of this manual 1575025 A 7 Birdie 2 Safety 2 1 Safety information WARNING A Do not use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as user manuals service manuals or instruction sheets supplied with this product or optional equipment If you are unable to understand the warnings cautions or instructions contact a healthcare professional dealer or technical personnel before attempting to use this equipment otherwise injury or damage may occur o The information contained in this document is subject to Il change without notice Check
8. wear If damage is found do not use Contact your Dealer or Invacare representative immediately LU Check the emergency lowering function both electrical and or mechanical Check all parts for external damage or wear If damage is found do not use Contact your Dealer or Invacare representative immediately LU Check that all hardware and attachment points for damage or wear Check all parts for external damage or wear If damage is found do not use Contact your Dealer or Invacare representative immediately Q Verify that the hand control is functional lifting and leg movements Q Charge the battery every day the lift is used LU Check the emergency stop function 1575025 A Maintenance 33 Birdie Safety inspection checklist A person who is suitably and properly qualified and well acquainted with the design use and care of the lift should perform periodic inspections Date of Inspection Initials THE CASTER BASE Inspect for missing hardware Base opens closes with ease Inspect and clear wheels of debris Inspect pivot joints for wear mE mi mi mi mi m Inspect casters and axle bolts for tightness Inspect casters for smooth swivel and roll THE BOOM Check all hardware and hanger bar supports Inspect for bends or deflections Inspect bolted joints of boom for wear Inspect to ensure that the boom is centered between the base legs Check the mast pivot bolt Ensure that the b
9. 5 930 centre to centre of castor g Turning radius 1400 1070 Height to upper 100 100 edge of legs Min free height 20 20 1575025 A Technical data 10 2 Electrical system Birdie Birdie Compact Voltage output Voltage supply 24 V DC max 250 VA 100 240 V AC 50 60 Hz Maximum current input Max 200 mA Protection class entire device IPX4 Min space for 340 300 patient in top position Max reach at 600 665 545 mm a Max reach from 665 545 base b Reach from base 240 415 with legs spread to 700 mm c Lifting range f 1235 1070 CSP Central Suspension Point o All measures are taken with 75 mm casters For 100 mm I casters add 15 mm for height measures and 20 mm for width Insulation class 2 R Class Il equipment Type B applied part Applied part complying with the specified requirements for protection against electrical shock according to IEC60601 1 Sound level 45 50 dB A Working ability 40 full lifts without battery charge with batteries at 50 of full capacity Intermittent periodic motor 10 max 2 min 18 min operation Battery capacity 2 9 Ah Manual emergency Yes No lowering Electric emergency Yes No Yes No lowering lifting Weights kg Birdie Birdie Compact Maximum lifting 180 150 capacity Total weight incl 42 36 hanger bar W
10. Invacare Birdie Birdie Birdie Compact EN Portable Patient Lift User Manual INVACARE This manual MUST be given to the user of the product BEFORE using this product read this manual and save for future reference Yes you can 2013 Invacare Corporation All rights reserved Republication duplication or modification in whole or in part is prohibited without prior written permission from Invacare Trademarks are identified by and All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted Contents About this manual Scope of delivery 0 2 0 o Safety information Operating Information Pinch Points and Positioning Radio Frequency Interference Product labeling Main parts of the lift Assembling the Mast to the Base Assembling the Electric Actuator to the Boom Mounting the hanger bar Disassembling of the lift Checking the service light Raising Lowering the Lift Raising Lowering an Electric Lift Closing Opening Legs Closing Opening Electric Legs 17 Closing Opening legs manually 18 5 4 Performing an Emergency Stop 18 5 5 Activating an Emergency Release 18 5 6 Charging the battery 0 0 20 Lifting the Patient sssssssssessersceeso 22 6 1 Safe Lifting ss seus ge 4 4 es pe eae Be Ga eae 22 6 2 Preparing to Lift clllccll c
11. and lift the patient off the surface of the bed When the legs of the lift are no longer under the bed return the legs of the lift to the maximum open position Closing Opening Electric Legs The hand control is used to open or close the legs of the base To close the legs press and we hold the legs closed button A 2 To open the legs press and hold the legs open button 8 i Al T aT J il The legs will stop moving when the button is released Birdie Closing Opening legs manually The manual leg spreader is operated by two pedals and or by the optional leg spreader handle To open the legs press the left pedal A with a foot 2 To close the legs press the right pedal with a foot With the optional handle bar To open the legs pull the leg spreader handle to the left 2 To close the legs push the leg spreader handle to the right 5 4 Performing an Emergency Stop Emergency Stop with CBJ Home control unit A oo Press the red emergency button on the control unit to stop the boom and patient from raising or lowering 2 To reset rotate the emergency button clockwise Emergency Stop with Jumbo Care control unit er l Press the red button on the control unit to stop the boom and patient from raising or lowering 2 To reset rotate the emergency button clockwise o For more information abou
12. ansfer Position the sling under the patient o Refer to the sling user manual for more information I about positioning slings 27 Birdie 3 One assistant should have the patient bend his knees and raise 5 Position the lift with one leg under the patient s head and the his head off of the floor other leg under the patient s bent knees o This assistant should support the patient s head with a ll pillow 4 The other assistant should open the legs of the lift 28 1575025 A Lifting the Patient Commode Transfer Guidelines Perform these steps in addition to those in 6 4 Lifting and Transferring the Patient page 26 when transferring to or from a commode o The slings with commode openings are designed to be used Il with either a commode chair or standard commode Before transferring the patient the patient lift should be guided to the bathroom facilities to check that it can be easily maneuvered towards the commode o Keep the sling straps inside of the legs of the lift il The Invacare patient lift is NOT intended as a transport il device If the bathroom facilities are NOT near the bed or if the patient lift cannot be easily maneuvered towards 6 Lower the boom so the hanger bar is directly over the patient s the commode then the patient MUST be transferred to chest a wheelchair and transported to the bathroom facilities 7 Attach the sling and proceed with the transfer Refer to 6 4 before using th
13. as far back as possible into the seat for proper positioning 1575025 A Lifting the Patient 31 Birdie 7 Maintenance 7 1 Maintenance and Safety Inspection WARNING N Risk of Falling Maintenance MUST be performed only by qualified personnel Improper assembly may cause injury or damage Regular maintenance of patient lifts and accessories is necessary to assure proper operation DO NOT overtighten the mounting hardware This will damage the mounting bracket Service Interval At normal daily operation a service check up should take place every year according to the Safety Inspection Checklist When performing annual or regular maintenance all parts designed to carry load must be as a minimum tested with maximum load All safety features must be checked according to EN ISO 10535 2006 Annex B LOLER Statement The UK Health and Safety Executive s Lifting Operations and Lifting Equipment Regulations 1998 require any equipment that is used in the workplace to lift a load be subject to safety inspection on a six monthly basis Please refer to the HSE web site for guidance www hse gov uk The person responsible for the equipment must ensure adherence to LOLER regulations 32 General Maintenance o Regular cleaning will reveal loose or worn parts enhance Ih smooth operation and extend the life expectancy of the lift Follow the maintenance procedures described in this manual to keep your patient l
14. assemble the patient lift If there are any issues or questions during assembly contact a local Invacare representative Refer to the contact information on the last page in this manual 1575025 A Setup 4 2 Assembling the Mast to the Base WARNING N The mast may be folded for storage or transporting Each time the mast is folded the mast MUST be properly secured to the base assembly Check all parts for visible defects or damage before assembly In case of any damage do not use the product and contact Invacare Make sure the emergency stop is activated before assembly or disassembly Take care when lifting components during assembly Some parts are heavy Always remember to adopt the correct lifting position Perform unpacking and assembly operation at floor level Lock both rear casters 8 Remove the locking pin A 2 Raise the mast assembly to an upright position by stepping with one foot on the leg and pulling the handle bar upwards until it locks in place Birdie Be sure that the pin is completely through the holes of the boom mounting bracket and the actuator assembly The boom assembly will pivot easily if the mounting hardware is aligned properly when the boom is secured to the mast o 5 Connect the actuator to the battery Plug the hand control into the battery 4 4 Mounting the hanger bar 3 Reinstall the locking pin through the mast and base
15. catch and move the hanger bar to the lower Ee E point of the carabiner 4 5 Disassembling of the lift 2 Remove optional leg spreader handle if attached Examine the control box to see if the service light is flashing 2 Lower the boom and narrow both legs completely 2 When service light is not flashing the lift is ready for use 3 Activate the emergency stop button and apply castor brakes When service light is flashing refer to the table 4 Remove the pipe pin and the motor piston from the boom reinstall the pipe pin in the piston end and lock the motor into the clips on the mast 5 Attach the hanger bar into the welded fork on the mast 6 Remove the locking pin from the base of the mast release the safety latch lower the mast and relocate the locking pin into the mast near the suspension axle of the mast The lift can now be located in the packaging box pulled on the rear wheels or parked in an upright position with the mast boom assembly pointing upwards 1575025 A 15 Birdie Initial Assembly A qualified technician has to reset the service light Locate the hand control 2 Press and hold the UP button and the DOWN button at the same time for five seconds 3 You will hear a sound when the service light has been reset Reassembly The lift requires service Contact your local Invacare dealer or representative for service 16 1575025 A 5 Usage 5 1 Introduction The
16. ces that could cause the patient lift to tip over Use steering handle on the mast at all times to push or pull the patient lift Wheelchair and bed wheel locks MUST be in a locked position before lowering the patient into the wheelchair for transport Before transferring check that the wheelchair weight capacity can withstand the patient s weight 1575025 A 6 2 Preparing to Lift o Refer to the Safety section in this manual and review the Il information in 6 1 Safe Lifting page 22 before proceeding further and observe all warnings indicated Before positioning the legs of the patient lift under a bed make sure that the area is clear of any obstructions WARNING N Risk of Injury The lift could tip and endanger the patient and assistants The legs of the lift must be in the maximum open position for optimum stability and safety If it is necessary to close the legs of the lift to maneuver the lift under a bed close the legs of the lift only as long as it takes to position the lift over the patient and lift the patient off the surface of the bed When the legs of the lift are no longer under the bed return the legs of the lift to the maximum open position 1575025 A Lifting the Patient A a Position the patient onto the sling Refer to your sling user manual Unlock the rear casters Open the legs Refer to 5 3 Closing Opening Legs page 17 23 Birdie 4 Use the stee
17. ck va Audible tone when battery low Refer to 5 6 Charging the battery page 20 Read Manual Date of manufacture YYYY C This product complies with Directive 93 42 EEC concerning medical devices The launch date of this product is stated in the EC declaration of conformity Safe Working Load Class Il equipment Type B applied part Do gt O pp WEEE conform Refer to 8 2 Disposal page 37 10 1575025 A 3 Overview 3 1 Main parts of the lift 1575025 A Overview Base Leg Caster Rear castor with brake Boom Mast Hanger bar Hook for sling Carabiner Actuator Manual emergency lowering handle Control unit with Battery Emergency Stop Hand control Locking pin Steering handle O DIO DB 0 9 S 0 0 0 0 0 0 0 Foot pedal for leg spreader Leg spreader handle optional Motor for electrical operation of legs optional Birdie 3 2 Accessories A CAUTION Compatibility of slings and hanger bars Invacare uses a Loop and Coat Hanger Bar System as do many other manufacturers Therefore other suitable patient transfer systems slings manufactured by other companies can be used on the Invacare patient lift range as well However we do recommend risk assessment is always to be carried out by a professional prior to issuing lifting equipment It is important tha
18. connecting slings to the patient lift the shortest of the straps MUST be at the back of patient for support Using long section will leave little or no support for patient s back The loops of the sling can be used to place patient in various positions Connect both sides of the sling equally Make sure that there is sufficient head support when lifting a patient Lifting the Patient D v o The slings may be equipped with color coded straps to assist ll with proper attachment Place the straps of the sling over hooks of the hanger bar 2 Match the corresponding straps on each side of the sling for an even lift of the patient 3 Use the lift Refer to 6 4 Lifting and Transferring the Patient page 26 25 Birdie 6 4 Lifting and Transferring the Patient 26 A WARNING Risk of Injury The lift could tip and endanger the patient and assistants Refer to the safety information and instructions in the following procedures BEFORE performing this procedure 6 1 Safe Lifting page 22 6 2 Preparing to Lift page 23 6 3 Attaching the Slings to the Lift page 25 5 2 Raising Lowering the Lift page 17 Invacare does not recommend locking of the rear casters of the patient lift when lifting a patient Invacare recommends locking the rear casters ONLY when positioning or removing the sling from around the patient Invacare does recommend that the rear casters be left
19. e patient lift again to position the patient Lifting and Transferring the Patient page 26 on a standard commode 2 Attach the slings to the lift Refer to 6 3 Attaching the Slings to the Lift page 25 1575025 A 29 Birdie 3 N o Elevate the patient high enough to clear the commode chair arms and have their weight supported by the patient lift Refer to 5 2 Raising Lowering the Lift page 17 Both assistants should help guide the patient onto the commode Lower the patient onto the commode leaving the sling attached to the hanger bar hooks o Invacare recommends that the sling remain connected to ll the hanger bar hooks during the patient s use of either the commode chair or standard commode When complete recheck for correct sling attachment Raise the patient off of the commode When the patient is clear of the commode surface use the steering handles to move the lift away from the commode Perform one of the following e Return the patient to the bed Reverse the procedures in 6 4 Lifting and Transferring the Patient page 26 5 2 Raising Lowering the Lift page 17 6 3 Attaching the Slings to the Lift page 25 e Return the patient to a wheelchair Refer to Wheelchair Transfer page 30 Bed Transfer Use the following guidelines when transferring to or from a bed 30 Position the patient as far over the bed as possible If patient is being transferred from a surface that is lower than the bed
20. ed of service or load is too high Contact your Dealer or Invacare representative Unusual noise from actuator Actuator is worn or damaged or spindle is bent Contact your Dealer or Invacare representative Boom will not lower in uppermost position Boom requires a minimum weight load to lower from the uppermost position Pull down slightly on the boom Boom will not lower during a power retraction Shoulder bolt at the junction of the boom and mast may not be properly installed Refer to 7 4 Checking and Tightening Mast Pivot Bolt page 35 The control unit emits a beeping sound during lifting and the motor stops Max load is exceeded Reduce the load and the lift will function normally i 1575025 A Contact your dealer if the above does not solve your problems 39 Birdie 10 Technical data 10 1 Dimensions and weight 40 Dimensions mm Birdie Birdie Compact Front rear castor 75 75 diameter Lowest position 655 730 CSP min height e Lifting area height 465 1685 515 1585 range CSP max height 1890 1800 d Leg length 1150 1000 Minimum internal 580 460 width i Total width closed 655 530 external measure Internal width at 910 780 maximum reach h Total width open 1040 890 internal measure Total width open 108
21. eering handle move the lift away from the stationary object Using the handles on the sling turn the patient so that he she faces the assistant operating the patient lift Detail C Lower the patient so that his feet rest on the base of the lift straddling the mast o The lower center of gravity provides stability making the ll patient feel more secure and the lift easier to move Move the patient lift with both hands firmly on the steering handle 1575025 A 10 II 12 13 14 Lifting the Patient o Read and understand the information that pertains to Il transfer to or from specific types of surfaces BEFORE performing this procedure 7 Bed Transfer page 30 s Floor Transfers Lifting from the Floor page 27 Wheelchair Transfer page 30 Commode Transfer Guidelines page 29 Raise or lower the lift to position the patient over the stationary surface o Be sure to raise or lower the patient enough to clear the I sides of the stationary object Lower the patient onto the stationary surface Lock the rear casters Detach the sling from the hanger bar Unlock the rear casters Move the lift away from the area Floor Transfers Lifting from the Floor Perform these steps in addition to those in 6 4 Lifting and Transferring the Patient page 26 when transferring from the floor 2 Determine if the patient has suffered any injuries from a fall If no medical attention is needed proceed with the tr
22. eight mast incl 21 17 5 battery excl hanger bar Weight leg section 19 16 5 1575025 A 4l Birdie 10 3 Electromagnetic compliance EMC information Medical Electrical Equipment needs to be installed and used according to the EMC information in this manual This equipment has been tested and found to comply with EMC limits specified by IEC EN 60601 1 2 for Class B equipment Portable and mobile RF communications equipment can affect the operation of this equipment Other devices may experience interference from even the low levels of electromagnetic emissions permitted by the above standard To determine if the emissions from the lift is causing the interference run and stop running the lift If the interference with the other device operation stops then the lift is causing the interference In such rare cases interference may be reduced or corrected by the following Reposition relocate or increase the separation between the devices Contact Invacare for any additional EMC information or EMC tables for the device environment 10 4 Environmental conditions Storage and transportation Operation Temperature 10 C to 50 C 5 C to 40 C Relative humidity 20 to 75 20 to 90 at 30 C not condensing Atmospheric pressure 700 hPa to 1060 hPa 42 10 5 Materials Component Material Base legs mast and boom Hanger bar Steel
23. ent lift is wiped clean of any moisture after use Periodically inspect all components of the patient lift for signs of corrosion Replace all parts that are corroded or damaged 1575025 A Pinch Points and Positioning WARNING N Risk of Injury Pinch points are present in several locations on the lift and fingers could be pinched The hanger bar can move suddenly and cause injury Always keep hands and fingers clear of moving parts When positioning lift be aware of the position of the hanger bar and the patient 2 3 Radio Frequency Interference WARNING Most electronic equipment is influenced by Radio Frequency Interference RFI CAUTION should be exercised with regard to the use of portable communication equipment in the area around such equipment If RFI causes erratic behavior PUSH the Red Power Switch OFF IMMEDIATELY DO NOT turn the Power Switch ON while transmission is in progress 1575025 A Safety 2 4 Product labeling Label location ie 180 k ere 5 E yee Poa Estado ea seg Lg o al Pars Ta 25 80 4647 ox e AM ir Pao Smo TR OK Symbols on the label Ela Emergency stop Emergency release hai Raise lower the boom Rte Open close legs p fal a Open close legs manually Birdie Tool less hanger bar attachment Refer to 7 6 Replacing the Hanger Bar page 36 Caster lo
24. ergency Stop page 18 The patient lift must be stored at normal room temperature If it is stored in a damp cold or wet environment then the motor and other mounting parts may be prone to corrosion For transportation and storage condition information refer to 10 4 Environmental conditions page 42 8 2 Disposal WARNING N Environmental Hazard This product has been supplied from an environmentally aware manufacturer that complies with the Waste Electrical and Electronic Equipment WEEE Directive 2002 96 CE Device contains lead acid batteries This product may contain substances that could be harmful to the environment if disposed of in places landfills that are not appropriate according to legislation DO NOT dispose of batteries in normal household waste They MUST be taken to a proper disposal site Contact your local waste management company for information Please be environmentally responsible and recycle this product through your recycling facility at its end of life 1575025 A After Use 8 3 Reuse This product is suitable for reuse The maximum number of times it can be reused is dependent upon product condition To prevent the transmission of infection the patient lift and slings must be cleaned after each use Before reuse or refurbishment of the lift refer to 7 3 Cleaning the Sling and Lift page 35 Always provide the user manual with the reused or refurbished lift 37 Birdie 9 T
25. ift in continuous service The Invacare Patient Lift is designed to provide a maximum of safe efficient and satisfactory service with minimum care and maintenance It is important to inspect all stressed parts such as slings hanger bar and any pivot points for signs of wear cracking fraying deformation or deterioration All parts of the Invacare patient lift are made of the best grades of steel but metal to metal contact will wear after considerable use Replace any defective parts immediately and ensure that the lift is not used until repairs are made Refer to the Safety Inspection Checklist for specific information regarding wear items There is no adjustment or maintenance of either the casters or brakes other than cleaning lubrication and checking axle and swivel bolts for tightness Remove all debris etc from the wheel and swivel bearings If any parts are worn replace these parts immediately If you question the safety of any part of the lift contact your Dealer or Invacare representative immediately and advise him her of your problem 1575025 A Daily Inspections The patient lift should be checked each time it is used Perform the following checks in addition to those listed in the Safety Inspection Checklist If you question the safety of any part of the lift do not use Contact your Dealer or Invacare representative immediately 0 Visually inspect the patient lift Check all parts for external damage or
26. ly charged The upper yellow diode will blink during charging and switch to continuous light when fully charged The lower green diode will light continuously when the control unit is connected to the mains and light up when any button on the hand control is pressed or when the electric emergency lowering is activated Io Jumbo Care control unit The battery indicator is located on the control box A The LEDs indicate the battery state See following table l Attach the power cord to the control box 2 Plug the power cord into a power outlet o The battery will charge in approximately 4 hours Charging Il must be done in a room with good air ventilation 3 Disconnect the power cord from the power outlet after the battery has been fully charged 1575025 A Battery Battery Description Indicator State Full The battery is OK no need for Charge charging 100 50 The third LED is GREEN omy Partial The battery needs to be charged Charge 50 25 The second LED is YELLOW Low The battery needs to be charged Less Charge than 25 The horn beeps when a button is pressed The first LED is YELLOW ELA Low The battery needs to be charged io Some of the functionality of the lift is blinking lost and it is only possible to lower the boom An audible alarm will sound horn will beep when battery is low If the audible alarm sounds during a t
27. n or damaged parts of the lift may cause injury to the patient or assistants After the first year of use the hooks of the hanger bar and mounting brackets of the boom should be inspected every six months to determine the extent of wear Check for signs of cracking fraying deformation or deterioration If these parts become worn replacement must be made Checking the carabiner Check the carabiner for wear at contact points and Do not use the lift if the carabiner measures less than 6 mm at these points Checking the boom pin Remove plastic part A 2 Turn carabiner up to see the welded pin 36 3 Check the pin O for wear Do not use the lift if the pin measures less than 7 mm 4 Insert the plastic part again 7 6 Replacing the Hanger Bar o If the scale is installed on the lift refer to the scale instruction I manual to replace the hanger bar Support the hanger bar with one hand Open the carabiner with the other hand Detail A Remove the hanger bar from the carabiner Reverse STEPS 3 to install the new hanger bar Check that the hanger bar is firmly attached to the carabiner The gate of the carabiner must be closed after the hanger bar is mounted UAWN 1575025 A 8 After Use 8 1 Transportation and Storage During transportation or when the patient lift is not to be used for some time the emergency stop button should be pushed in Refer to 5 4 Performing an Em
28. o 23 6 3 Attaching the Slings to the Lift 25 6 4 Lifting and Transferring the Patient 26 Floor Transfers Lifting from the Floor 27 Commode Transfer Guidelines 29 Bed Transfer is rene en eee ee eee 30 Wheelchair Transfer 00000005 30 Maintenance 0c cee cece cece eee ceece 32 7 1 Maintenance and Safety Inspection 32 Safety inspection checklist 34 72 Lubricating the Lift 0004 35 7 3 Cleaning the Sling and Lift 35 74 Checking and Tightening Mast Pivot Bolt 35 7 5 Checking the carabiner and its mounting 36 7 6 Replacing the Hanger Bar 04 36 After Use a musas eles seres i a a re ace cega eee 37 8 1 Transportation and Storage 37 8 2 Disposal iod soar asi ob Save hanes Peter ded Senor de beet 37 8 3 Reusen n sacana a E Sera Pan tus cies Babe 37 Troubleshooting 0 0 c cece eee ecceeees 38 9 1 Identifying and repairing faults 38 Technical data ccc cece cece cece eee eeee 40 10 1 Dimensions and weight 04 40 10 2 Electrical system 0 0 0 0 000 0000 41 10 3 10 4 10 5 Electromagnetic compliance EMC information Environmental conditions Materials General 1 1 About this manual Thank you for choosing an Invacare product This u
29. olt is tightly secured Inspect pivot joints for wear O OF OOO O SLINGS AND HARDWARE Q Check all sling attachments each time it is used to ensure proper connection and patient safety U Inspect sling material for wear U Inspect straps for wear U Inspect stitching THE MAST Q Mast must be securely assembled to boom U Inspect for bends or deflections Q Inspect pivot joints for wear THE ELECTRIC ACTUATOR ASSEMBLY CLEANING LU Whenever necessary THE HANGER BAR Check the bolt hooks for wear or damage Check sling hooks for wear or deflection Inspect pivot joints for wear Check the carabiner for wear at contact points Refer to 7 5 Checking the carabiner and its mounting page 36 LU Check the welded pin that is carrying the carabiner at the boom Refer to 7 5 Checking the carabiner and its mounting page 36 LULU OC Check for leakage O Inspect hardware on mast boom and base CL Check for wear or deterioration If damaged return to factory I Cycle to ensure smooth quiet operation of the electric actuator 34 1575025 A 7 2 Lubricating the Lift The Invacare lift is designed for minimum maintenance However a six month check and lubrication should ensure continued safety and reliability Keep lift and slings clean and in good working order Any defect should be noted and reported to your Dealer or Invacare representative as soon as possible Refe
30. operation of the patient lift is an easy and safe procedure o Before using the lift with a patient refer to the following I procedures for safety information and instruction e 2 2 Operating Information page 8 e 64 Lifting and Transferring the Patient page 26 5 2 Raising Lowering the Lift WARNING N Risk of Injury The lift could tip and endanger the patient and assistants Invacare does not recommend locking of the rear casters of the patient lift when lifting a patient Invacare does recommend that the rear casters be left unlocked during lifting procedures to allow the patient lift to stabilize itself when the patient is initially lifted from a chair bed or any stationary object Raising Lowering an Electric Lift The hand control is used to raise or lower the lift To raise the lift Press and hold the UP button to raise the boom and the patient 2 To lower the lift Press and hold the DOWN button to lower the boom and the patient 1575025 A Usage il Release the button to stop raising or lowering the lift 5 3 Closing Opening Legs WARNING N Risk of Injury The lift could tip and endanger the patient and assistants The legs of the lift must be in the maximum open position for optimum stability and safety If it is necessary to close the legs of the lift to maneuver the lift under a bed close the legs of the lift only as long as it takes to position the lift over the patient
31. pe Ra WARNING Ensure that the locking pin is correctly inserted N Risk of injury 4 3 Assembling the Electric Actuator to the E Fi ay Aa bars meda tiar this ite Geet henger ar System Boom aa the hanger bar is suitable for the patient 5 5 and the actual lift or transfer required Check that the hanger bar is firmly attached to the carabiner The safety catch of the carabiner must be closed after the hanger bar is mounted and before lifting the patient There is risk of detachment if the safety catch is not correctly closed Loosen the hanger bar by pulling it downwards out of the welded fork on the mast 2 Remove the quick release pin from the boom mounting bracket 3 Align the holes of the boom mounting bracket with those of the actuator 4 Reinstall the quick release pin and secure with the clip O 14 1575025 A Setup 4 6 Checking the service light Jumbo Care control unit only CAUTION N Each time the lift is assembled and before using the lift the service light should be checked The service light should only be reset by a qualified technician and must never be reset by untrained personnel Open the carabiner by pushing the safety catch backwards RE mol with one hand 2 Hold the safety catch in the open position and attach the hanger bar to the upper part of the carabiner with the other hand 3 Release the safety
32. r to the figure for lubrication points Lubricate all pivot points with a light grease waterproof auto lubricant Wipe all excess lubricant from lift surface Hanger Bar Boom Mounting Bracket Boom Mast Mount Mast Mounting Bracket DAWN 7 3 Cleaning the Sling and Lift Cleaning the Sling Refer to the washing instructions on the sling and to the sling manual for cleaning details 1575025 A Maintenance Cleaning and Disinfecting the Lift To prevent cross infection the hoist must be cleaned and disinfected after each use A soft cloth dampened with water and a small amount of mild detergent is all that is needed to clean the patient lift The lift can be cleaned with non abrasive cleaners Never use acids alkaline or solvents for cleaning the lift Dry the lift carefully after cleaning Motors control unit and mounting parts can be damaged if the lift is cleaned any other way than stated above The lift must be wiped with a moistened firmly wrung cloth with ordinary household disinfectants Only use disinfection detergents approved by the facility 7 4 Checking and Tightening Mast Pivot Bolt Check that the bolt is through the bracket and the locknut is tight and secure 2 If needed do one or more of the following e Tighten locknut and back off the locknut 1 8 of a turn e Replace the locknut 35 Birdie 7 5 Checking the carabiner and its mounting WARNING N Risk of Injury Wor
33. ransfer complete that transfer and then charge the battery 1575025 A Usage 21 Birdie 6 Lifting the Patient 6 1 Safe Lifting 22 A WARNING Risk of Injury The lift could tip and endanger the patient and assistants Refer to the safety information and instructions in the following procedures BEFORE performing this procedure 6 2 Preparing to Lift page 23 6 3 Attaching the Slings to the Lift page 25 6 4 Lifting and Transferring the Patient page 26 Although Invacare recommends that two assistants be used for all lifting preparation transferring from and transferring to procedures our equipment will permit proper operation by one assistant The use of one assistant is based on the evaluation of the health care professional for each individual case DO NOT exceed maximum weight limitation of the patient lift See 10 Technical data page 40 DO NOT attempt any transfer without approval of the patient s physician nurse or medical assistant Thoroughly read the instructions in this User Manual observe a trained team of experts perform the lifting procedures and then perform the entire lift procedure several times with proper supervision and a capable individual acting as a patient WARNING Risk of injury The lift could tip and endanger the patient and assistants During transfer with patient suspended in a sling attached to the lift DO NOT roll caster base over uneven surfa
34. ring handle to push the patient lift into position WARNING N When using the lift in conjunction with beds or wheelchairs be aware of the position of the lift in relationship to those other devices so that the lift does not become entangled im Lower the patient lift for easy attachment of the sling 6 Proceed to 6 4 Lifting and Transferring the Patient page 26 24 1575025 A 6 3 Attaching the Slings to the Lift A 1575025 A WARNING Risk of Falling Improperly installed slings or damaged slings can cause the patient to fall or cause injury to assistants Use an Invacare approved sling that is recommended by the individual s doctor nurse or medical assistant for the comfort and safety of the individual being lifted After each laundering in accordance with instructions on the sling inspect sling s for wear tears and loose stitching Bleached torn cut frayed or broken slings are unsafe and could result in injury Discard immediately DO NOT alter slings Be sure to check the sling attachments each time the sling is removed and replaced to ensure that it is properly attached before the patient is removed from a stationary object bed chair or commode WARNING If the patient is in a wheelchair secure the wheel locks in place to prevent the chair from moving forwards or backwards The hanger bar MUST be attached to the lift BEFORE attaching the sling When
35. roubleshooting 9 1 Identifying and repairing faults A WARNING Birdie and Birdie Compact Only personnel having received the necessary instruction or training by Invacare must perform service and maintenance on Symptoms Faults Solution Patient lift feels loose Mast Base joint loose Refer to 4 2 Assembling the Mast to the Base page 13 Tie Rods are loose Contact your Dealer or Invacare representative Casters Brakes noisy or stiff Fluff or debris in bearings Clean casters from fluff and debris Noisy or dry sound from pivots Needs lubrication Refer to 7 2 Lubricating the Lift page 35 Electric actuator fails to lift or legs fail to open when button is pressed 38 Hand control or actuator connector loose Connect hand control or actuator connector Ensure connectors are seated properly and fully connected Battery low Charge batteries Refer to 5 6 Charging the battery page 20 RED emergency stop button pressed IN Rotate RED emergency stop button CLOCKWISE until it pops out Battery not connected properly to control box Reconnect the battery to the control box Refer to 5 6 Charging the battery page 20 1575025 A Troubleshooting Symptoms Faults Solution The connecting terminals are damaged Replace the battery pack Refer to5 6 Charging the battery page 20 Boom or leg actuator in ne
36. ser manual contains important information about the handling of the product In order to ensure safety when using the product read the user manual carefully and follow the safety instructions Please note that there may be sections in this user manual which are not relevant to your product since this manual applies to all existing modules on the date of printing Symbols in this manual In this user manual warnings are indicated by symbols The warning symbols are accompanied by a heading that indicates the severity of the danger WARNING AN Indicates a hazardous situation that could result in serious injury or death if it is not avoided CAUTION N Indicates a hazardous situation that could result in minor or slight injury if it is not avoided IMPORTANT Indicates a hazardous situation that could result in damage to property if it is not avoided 1575025 A General Tips and Recommendations Gives useful tips recommendations and information for efficient trouble free use Io This product complies with Directive 93 42 EEC C concerning medical devices The launch date of this product is stated in the CE declaration of conformity 1 2 Intended Use WARNING N Risk of Falling The Invacare mobile patient lift is NOT a transport device It is intended to transfer an individual from one resting surface to another such as a bed to a wheelchair Invacare slings and patient lift accessories are specifically
37. t the Jumbo Care control unit IL see separate Jumbo Care user manual or ask your local Invacare dealer 5 5 Activating an Emergency Release Emergency release with CBJ Home control unit If the hand control fails the boom can be lowered by using the circular switch for emergency release 1575025 A O ps Lower the boom by pressing and holding button A at the front of the control unit 2 Stop lowering the boom by releasing the button A Emergency Release with Jumbo Care control unit eaten mada O D o C e 0 o l o o E E gt O Insert a pen into the hole labeled Emergency Up or Emergency Down on the control box o For more information about the Jumbo Care control unit Il see separate Jumbo Care user manual or ask your local Invacare dealer 1575025 A Usage Activating an emergency release manually Not available on Birdie Compact For the case of partial or total power failure or if the battery runs down while using the lift Birdie is equipped with a manual emergency release system located at the bottom of the actuator o It is recommended that the primary emergency release be Il used The secondary manual emergency release is only a back up to the primary emergency release I Pull up on the emergency grip and push down on the boom at the same time The manual emergency release system will only operate with a patient in the lift It can
38. t the Task Individual Load Environment and Equipment are considered in the risk assessment Always choose the sling design and size according to the clients weight size and physical ability whilst considering the type of transfer to be carried out Do only use slings that are suitable for a Loop and Coat Hanger Bar System Do not use slings for Keyhole Hanger Bar or for Tilting Frame Hanger Bar designs Available accessories 4 point hanger bar Coat Hanger Bar System 45 or 55 cm wide e 2 point hanger bar Coat Hanger Bar System 35 45 or 55 cm wide Scale to be mounted with the hanger bar e Handle for leg spread Sling models for Loop and Coat Hanger Bar System e Full body support slings without head support e Full body support slings with head support e Slings for dress toileting with or without head support Slings for amputee 1575025 A 4 Setup 4 1 Safe Assembly A o WARNING Risk of Injury Improper assembly may cause injury or damage Assembly MUST be performed only by qualified personnel Use only Invacare parts in the assembly of this patient lift The base legs the mast boom pump assembly and the hanger bar are manufactured to specifications that assure correct alignment of all parts for safe functional operation DO NOT overtighten the mounting hardware This will damage the mounting bracket There are no tools required to

Download Pdf Manuals

image

Related Search

Related Contents

TCL-Digital H32E4443 32" HD-ready Lime LED TV  e-paper 6-2014 - Technik zu Hause  Mode d emploi Pingouins  YAWL Editor 1.1 User Manual  Manuale utilizzo motore `Mercury Verado 200 DTS`  McIntosh MC-2kw User's Manual  Pro Series 2, short user manual E  Reports and Music Lists - Natural Broadcast Systems  33012 FLEX SERV SERIES E FRENCH.indd  Racal Guardall: Countess User Manual  