Home

TB200/400 Installation Guide

image

Contents

1. O 73e Yeastar TB200 400 Installation Guide Version 1 0 Date April 20 2015 Yeastar Information Technology Co Ltd TB200 400 Installation Guide Contents 0 TREN OVS LL mmmummvmimrrrmmmimrrrir ves cckccuacacnk i suntiki aanahanisandvsnteneavenieaniuna 3 1 Preparation before Installation ccccccesssseeeeeeeeeeeeeeeeeeseneneeeeeeeeeeeeeeeeeeeeneees 4 2 Hardware Specifications sain isecasecteeciccssccstecsescivecennzanectbnce cactisikecexecacecessxscsneaents 5 2 1 LED Indicators and Ports ccccstacscascncatenscenathasedtanens scat wanaedeariadgassdeusentiechysastdertea 5 2 2 Specifications and Operating Environment cccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 6 3 TB200 400 Installation i sisssssssecsssassecssswsssnsisassestasnsasnssensnendeasheniacsincesaenssentacsinensacs 7 3 1 Placement Instructions sic ciiscsercreiwsecsteinsdnerdinternternsendrsteteentuentwcnuntenwcstdesewcnantabs 7 3 2 Installation MST CHONES site ceiie sucked sineeicdl abdenddniinieiide biehaaetreeiduemutdogedbidaaiecasdouecedet 7 3 2 1 Connection of Ethernet POrtS eeeeeeeeereeeeeeenrrrrrereeeehhhrrrrreseehhrhhnrrhrrree 7 3 2 2 Connection of BRI Ports isccsiccsccissssscaviasscctssassenaxtesacntetasaneaviassacsdcaveecseetese 7 3 2 9 Power Connector ceninin ie ieai i iiia iiS 8 3 2 4 Connection Diagram ieeereeeeeereeenerrrrrrerrrrehnrrrrrreeenehhhhrrrrerrresssehnrerrree 8 4 TB200 400 Basic Configurations eee
2. admin would be erased 0 3 Yeastar 10 11 TB200 400 Installation Guide 5 Conclusion This Installation Guide only explains the installation and basic settings of TB200 400 BRI VoIP Gateways For more functionality and advanced settings please refer to the relative documents as below Yeastar TB BRI VoIP Gateways Datasheet Yeastar TB BRI VoIP Gateways User Manual The End a 46 Yeastar 11 11
3. browser on PC In the address bar enter the IP address click Enter button and then you can see the Web Configuration Panel login page see Figure 4 1 2 Enter the Admin User Name and Password to log in 192 168 6 125 192 168 6 125 7 fv BRI VoIP Gateway for Cost Reduction amp NeoGate Configuration Panel User Name admin NEQGATE Pae p A re Emma Language English lt es Copyright 2006 2015 Y eastar Information Technology Co Ltd All Rights Reserved Figure 4 1 TB200 400 Web Configuration Panel Login Page Via the configuration interface the admin can make all the system configurations including network settings LAN WAN Firewall VPN DDNS VLAN etc system parameters configuration time zone password etc internal settings Web access port etc BRI ports list VolP Trunks Trunk Groups Hotline call logs search download firmware update and reset etc 6 Atter saving the changes remember to click the Apply changes button to make the changes take effect 0 46 Yeastar 9 11 TB200 400 Installation Guide 4 2 Network Settings After logging in the admin configuration interface generally the first step is to configure the IP address If the LAN ports are connected to the network their IP addresses need to be configured If not just configuring the IP address of the LAN port which is connected to the local area network of the company
4. is OK LAN Settings Click Network Preferences gt LAN Settings on the left menu bar of the web configuration interface LAN port is used for the interoperability of IP terminals and the device If the LAN port is connected to the company s LAN please configure the correct IP address and corresponding subnet mask Please note that after changing the IP address of LAN port TB200 400 should be rebooted to make the new changes to take effect 4 3 Make and Receive Calls 1 Calls from BRI to SIP Users should be able to receive BRI to SIP call after configuring a route on TB200 400 and an inbound route on SIP server if needed Please refer to Yeastar TB BRI VoIP Gateways User Manual for details 2 Calls from SIP to BRI Users should be able to make SIP to BRlcall after configuring a route on TB200 400 and an outbound route on SIP Server Please refer to Yeastar TB BRI VoIP Gateways User Manual for details 4 4 Reset to Factory Defaults To reset to factory defaults you could follow the below instruction Press the RESET button located in the back panel with a paper clip or a pencil tip You can see the RUN indicator stops flicker and turns solid When the RUN indicator turns off the button could be released and system begins to reset During the process please do not power off until the RUN indicator become normal which means the reset process is completed Note after resetting all the configurations made by the
5. eeeeeeeeeeeeeeeeeeeeeeeeeeeeneeeeeeeeeeeeeennneees 9 4 1 Logging in the Web Configuration Panel eereeeeeerrrrrrrrrrrennnrrrrrerreenenrrrrse 9 4 2 Network Settings sree rken au akren EA KE REENEN EEE EEA EAER ETES 10 4 3 Make and Receive Calls 0 ccccceeeeeeeeeeeeeeeeeeeeeeeeeeeceseeeseeeeeeeeeeeeeeeeeeeeeeees 10 4 4 Reset to Factory Defaults eeeeeeerrrrrrrrrrennrrrrrrrressenhrrrrrrrresnehehnherrrreesnne 10 5 COMCIUSIOM occ sce cecessecetcassecsannscenstsnsnecannnsaessensseasennsas inca taanvacasbiataraiecaxstasseatacaincaie 11 0 46 Yeastar 2 11 TB200 400 Installation Guide 0 Introduction Yeastar TB200 400 is a compact and reliable standalone VoIP BRI gateway BRI VoIP VoIP BRI offering 2 or 4 BRI ports for companies using ISDN BRI lines an easy cost effective and flexible integration into any VoIP system or enabling any IP PBX to be connected to the public ISDN network This Guide explains how to install TB200 400 BRI VoIP Gateway how to log in web interface etc 0 46 Yeastar 3 11 TB200 400 Installation Guide 1 Preparation before Installation Contents of the Box Upon receiving TB200 400 gift box please open the package and check if all the items are supplied as TB200 400 Packing List See Sheet 1 If there is any problem please contact your provider Note please make sure the following devices are available before installation Sheet 1 TB200 400 ao List IEC Ns TB200 400 Device
6. mm x 160 mm x 44mm Power Supply 12V 1A Operating Temperature 0 to 40 C 32 to 104 F Storage Temperature 20 to 65 C 4 to 149 F Humidity 10 90 Non condensing 0 46 Yeastar 6 11 TB200 400 Installation Guide 3 TB200 400 Installation To avoid unexpected accident personal injury or device damage please read the following instructions before installing the Gateway 3 1 Placement Instructions Ambient Temperature to avoid overheating please do not run TB200 400 in the place where the ambient temperature is above 104 F 40 C Ventilation please make sure that the device has good ventilation around Anti jamming there may be some sources of interference that might affect the normal running of the Gateway It s highly recommended that the device gt Should be placed away from high power radio radar transmitters and high frequency and high current devices gt Is using independent power junction box and effective anti grid interference measures have been taken Mechanical load Please make sure that the device is placed steadily to avoid any accident that might cause damage If placed on the desktop please ensure it is horizontally placed 3 2 Installation Instructions Place the Gateway in a suitable place and then connect the power adapter and all other cables to complete the installation 3 2 1 Connection of Ethernet Ports TB200 400 provides one 10 100M adaptive RJ45 Ethernet LAN port LAN Port Con
7. nection Connect one end of a network cable to the LAN port of the Gateway and the other end to any port of company s LAN switch router If the LAN port is connected to PC directly not via a switch please use cross over cable 3 2 2 Connection of BRI Ports The BRI port could be connected to the BRI line and the BRI port of a traditional PBX with a BRI RJ45 RJ11 cable 0 46 Yeastar 7 11 TB200 400 Installation Guide 3 2 3 Power Connection Connect the power adapter to the Gateway s power port and then plug the power adapter into an electrical outlet Press the On switch to power on the Gateway The gatewaywill start booting In the meantime users would see that the POWER and RUN indicator lights turn on Please switch off the power before plugging or unplugging the cables 3 2 4 Connection Diagram POWER RESET RUN CONSOLE 2 Lcoal Network 34 NTBA Figure 3 1 TB200 400 Connection Diagram Front Panel i Power Outlets i Figure 3 2 TB200 400 Connection Diagram Rear Panel 0 46 Yeastar 8 11 TB200 400 Installation Guide 4 TB200 400 Basic Configurations 4 1 Logging in the Web Configuration Panel TB200 400 provides web based configuration interface for administrator The user can manage the device by logging in the web interface Check the factory defaults below IP address http 192 168 5 150 User Name admin Default Password password 1 Start the
8. unit Power cord PC 1 For the input of 220V AC power Network cable PC 1 Mounting ears PC 3 Long mounting ear 1 PC short mounting ear 2 PCS M3 Screw PC 9 Warranty card PC 1 With Serial Number printed for Repair amp Return se Yeastar 4 11 TB200 400 Installation Guide 2 Hardware Specifications 2 1 LED Indicators and Ports Front Panels se Yeastar Reset button Power status System status LAN port Console port BRI port status O BRI port se Yeastar ag HH 000 O O CO Figure 2 1 TB200 400 Front Panels Table 2 1 Description of Front Panels On Off Blinking Not Blinking Off Blinking On Off Press the RESET button to restore the factory defaults The power is switched on The power is switched off The system is running properly The system goes wrong LAN port is for the connection to Local Area Network LAN For Debugging The BRI line is disconnected The BRI line is connected or in use There is no BRI module inserted For the connection of ISDN BRI lines 5 11 TB200 400 Installation Guide Rear Panel Figure 2 2 TB200 400 Rear Panel Table 2 2 Description of Rear Panels No ndeaton Deserpion Power Switch Switch the device on or off Power Inlet For connection of power supply 2 2 Specifications and Operating Environment Table 2 3 TB200 400 Specifications and Operating Environment te Ser Size LxWxH 213

Download Pdf Manuals

image

Related Search

Related Contents

3com Express Service, 1-Year, 8x5xNext Business Day, Category 7  DoubleTap® Integrated Brake Shifter  IP-852 Channel User's Guide  Trex WBFGATEDBLKIT Use and Care Manual  MODE Demploi GMA ASSO  GenTarget`s EcoTMPlasmid DNA Miniprep Kit User Manual  POA2 manual - Wargames Board  Hampton Bay 55296 FAQ  Data Sheet - Mouser Electronics  Kompernass KH 525 Operating Instructions  