Home
Combispin FVL-2400N
Contents
1. in 1989 and after the successful approbation and improvement was patented in 1994 V K Bankovskis et al Riga Latvia Pat No P94 74 Combi spin FV 2400N is designed for handling small quantities of liquid micro quantity enzyme reactions mixture assembling mixing inside the microtest tubes before the thermoincubation in dry block cooler heater thermostats thermal cycler etc lt helps to save working space in laminar or PCR boxes MIXAND SPIN INONE COMBI SPIN Page 4 3 1 3 2 3 4 k 3 3 Getting started Unpacking Remove packing materials carefully and retain them for future shipment or storage of the unit Examine the unit carefully for any damage incurred during transit The warranty does not cover in transit damage Complete set Package contents Standard set Combispin FVL 2400N Mini Centrifuge Vortex 2 22 2222 nenn 1pce Spare TUS6 u ade a i eed k o ae 1pce R 0 5 0 2 76106 mussen pee ea a Se ee ee Es ee ee 1 pce R 1S OOF O tog ie ao aisiais ra aa kate a igh ae De tos 1 pce vortex head with 2 mmeccentric 00 0000s 1 pce Operating manual Certificates 1 copy Optional accessories R 2 0 5 rotor 4 22 2042 eee 2 ae oe bee tbe er nenn on request R 2 0 5 0 2rotor 2 eee on request SR 16 rotor O32 iwi 2 12 22 20 ne bids Pee hoe Pach on request O 20502 O R 2 0 5 0 2 sR 16 wr lt Setup place the uniton horizontally even working surface position t
2. into the unit disconnect it from the electric circuit and have it checked by a repair and maintenance technician Do not operate the unit in premises where condensation can form Operating conditions of the unit are defined in section 5 Specifications DURING OPERATION Do not open the lid during work run up or run down of the rotor Do not operate the unit in environments with aggressive or explosive chemical mixtures Please contact manufacturer for possible operation of the unit in specific atmospheres Do not use rotors with visible signs of corrosion wear or mechanical damage Do not operate the unit if it is faulty or has been installed incorrectly Do not use outside laboratory rooms BIOLOGICAL SAFETY It is the user s responsibility to carry out appropriate decontamination if hazardous material is spilt on or penetrates into the equipment Page 3 2 General Information Combispin FVL 2400N Mini Centrifuge Vortex is specially designed for the genetic engineering researches especially for PCR diagnostics experiments It can be used also in biochemical clinical laboratories microbiological and industrial biotechnology laboratories Combi Spin FVL 2400N ensures possibility for the simultaneous mixing and separation of samples using centrifuge and mixing modules located on the common spin module Combi Spin the previous name Micro Spin was invented and for the first time described published by Biol Dr V Bankovskis
3. D Medical Biological Research amp Technologies Combispin FVL 2400N Mini Centrifuge Vortex iv D Combi Spin FVL 2400N biosan Operating Manual for versions Certificate V 1AB V 1A3 V 1A12 V 1AA V 1AC Contents Safety Precautions General Information Getting Started Operation Specifications Maintenance Warranty and Claims oo N OOA ON Declaration of Conformity Page 2 1 Safety Precautions The following symbol means N Caution Make sure you have fully read and understood the present Manual before using the equipment Please pay special attention to sections marked by this symbol GENERAL SAFETY Use only as specified in the Operating Manual provided The unit should be saved from shocks or falling After transportation or storage keep the unit under room temperature for 2 3hrs before connecting it to the electric circuit Use only cleaning and decontamination methods recommended by the manufacturer Do not make modifications to the design of the unit ELECTRICAL SAFETY Connect only to electric circuit with voltage corresponding to that on the serial number label Do not plug the unit into an ungrounded power socket and do not use an ungrounded extension lead Ensure that the plug is easily accessible during use Disconnect the unit from the electric circuit before moving Disconnect the power cord plug from power socket to turn off the unit If liquid penetrates
4. VL 2400N Mini Centrifuge Vortex Serial number Date of sale Page 10 8 Declaration of Conformity Declaration of Conformity Eguipment name Directive Manufacturer Type of eguipment Applied Standards FVL 2400N Combispin Mini Centrifuge Vortex EMC Directive 2004 108 EC Low Voltage Directive 2006 95 EC RoHS 2011 65 EC WEEE 2002 96 EC amp 2012 19 EU SIA BIOSAN Ratsupites 7 build 2 Riga LV 1067 Latvia EN 61326 1 Electrical equipment for measurement control and laboratory use EMC requirements General requirements EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use General requirements EN 61010 2 20 Particular requirements for laboratory centrifuges Signature Svetlana Bankovska Managing director 2 06 2013 We declare that this product conforms to the requirements of the above Directive s Signature Aleksandr Shevchik Engineer of R amp D 42 06 2815 Date Date Biosan SIA Ratsupites 7 build 2 Riga LV 1067 Latvia Phone 371 67426137 Fax 371 67428101 http www biosan iv Version 1 05 December 2013
5. bators and closed laboratory rooms at ambient temperature from 4 C to 40 C in a non condensing atmosphere and maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C 5 1 Fixed rotation speed 2800 rpm 50 Hz 3500 rpm 60 Hz 5 2 Acceleration time to max speed 00 00000 cece eee 5s 5 3 Maximum continuous operation time 60 min 5 4 DIMENSIONS indem a id eee be dee 190x235x125 mm 5 5 Operating voltage power consumption 230 V 50 Hz 30 W 0 13 A 230 V 60 Hz 25 W 0 1 A or 120 V 50 60 Hz 30 W 0 27 A 5 6 Weight sirri iii iii i a ee 1 7 kg Accurate within 10 Optional Description Catalogue number accessories R 2 0 5 rotor for 8x2 ml and 8x0 5 ml BS 010205 CK microtest tubes R 2 0 5 0 2 rotor for 6x2 ml 6x0 5 ml and 6x0 2 mn BS 010205 DK microtest tubes SR 16 rotor for 2 strips of 8x0 2 ml BS 010202 AK microtest tubes Replacement parts Description Catalogue number R 1 5 rotor for 12x1 5 ml microtest tubes BS 010205 AK R 0 5 0 2 rotor for 12x0 2 ml and 12x0 5 ml BS 010205 BK microtest tubes Vortex head Vortex head with 2 mm eccentric BS 010202 S13 Biosan is committed to a continuous programme of improvement and reserves the right to alter design and specifications of the equipment without additional notice Page 8 6 1 6 2 6 3 6 4 Maintenance If the unit re
6. guires maintenance disconnect the unit from the electric circuit and contact Biosan or your local Biosan representative All maintenance and repair operations must be performed only by gualified and specially trained personnel Standard ethanol 75 or other cleaning agents recommended for cleaning of laboratory equipment can be used for cleaning and disinfection of the unit Fuse replacement Disconnect the unit from electric circuit Open the fuse holder located on rear side of the device by turning its cover counter clockwise Replace with the correct fuse 250 mA for 230 V or 500 mA for 120 V Page 9 7 1 1 2 7 3 7 4 Warranty and Claims The Manufacturer guarantees the compliance of the unit with the requirements of Specifications provided the Customer follows the operation storage and transportation instructions The warranted service life of the unit from the date of its delivery to the Customer is 24 months Contact your local distributor to check availability of extended warranty If any manufacturing defects are discovered by the Customer an unsatisfactory equipment claim shall be compiled certified and sent to the local distributor address Please visit www biosan lv Technical support section to obtain the claim form The following information will be required in the event that warranty or post warranty service comes necessary Complete the table below and retain for your records Model Combispin F
7. he unit so that there is easy access to the plug according to EN 61010 2 20 people and hazardous materials must not be within a 300 mm area around the device during the centrifuge operation Rotor replacement The unit is provided with the fixation mechanism for all the types of the above mentioned rotors operator can easily change rotor for the desired type of tubes in 3 5 s To change a rotor fig 1 2 hold it with one hand and turn the vortex head fig 1 1 counterclockwise to set rotor free Change the rotor and turn in the vortex head back Page 5 4 Operation Recommendation during operation 4 1 4 2 4 2 1 4 2 2 4 2 3 4 2 4 4 3 4 3 1 Page 6 Check the rotor for any signs of wear and replace if necessary Insert EVEN number of tubes in rotor one opposite another The opposite tubes must be filled equally 2 TUBE 4 TUBE 6 TUBE FULL ARRANGEMENT ARRANGEMENT ARRANGEMENT ARRANGEMENT Connect unit to a properly grounded power socket Operation in the quick centrifugation mode Turn the switch Fig 1 4 into position QS Quick Spin Open the lid and place EVEN number of tubes to the rotor sockets Fig 1 2 opposite one another Close the lid Press the QS Fig 1 3 button for quick mixing sedimentation and hold it pressed for the desired time The unit will automatically when the QS button is released Note Do not open the lid during work run up or shutoff of the rotor The unit stops automatica
8. lly when the lid is open Turn the switch Fig 1 4 into position O OFF Operation in the vortex mode Turn the switch Fig 1 4 into position QS Fig 1 General view 4 3 2 4 3 3 4 3 4 4 4 4 4 1 4 4 2 4 4 3 4 5 Gently holding a tube with fingers at its upper part press the tube s lower part to the vortex head cavity bottom Fig 1 1 Press QS button for mixing and hold it pressed till full sediment dissolution Caution Remember thatthe angle of hydrodynamic shift as well as the force of tubes pressing to the vortex head are decisive factors of sediment dissolution effectiveness To avoid fast erase of vortex head and plastic tube s surfaces don t press tubes to the vortex head too strong Turn the switch Fig 1 4 into position O OFF Operation in the long centrifugation mode Operation in the long centrifugation mode for more than 1 min is used for blood and eucariotics cells sedimentation including micro organism cells dissolving of hardly soluble components or salts dense sediments in analytical research etc Open the lid and place EVEN number of tubes to rotor sockets Fig 1 2 opposite one another Close the lid Turn the switch Fig 1 4 into position II LS Lon Spin to start centrifugation Turn the switch into position O OFF to stop centrifugation Disconnect unit from electric circuit Page 7 5 Specifications The unitis designed for operation in cold rooms incu
Download Pdf Manuals
Related Search
Related Contents
2015 CLIMBING EQUIPMENT Parni generator Generator pare Steam generator Parný GuIde prATIque des exercices comparatistes アラーム出力付体表面温度検査システム 固定形(PDF 419 KB) KVM Extender User Manual descargar - Energy Sistem datAshur Personal User Manual Silex technology Pricom SX-2000U2 User's Manual Copyright © All rights reserved.