1. KCM 5311 35x Zoom H 264 2 Megapixel IP D N PoE Box Camera Hardware User s Manual DC 12V PoE Ver 2011 4 8 ACTI Connecting Vision lt pq ACTI KCM 5311 Hardware User s Manual Connecting Vision Table of Contents 0 Precautions 3 1 Introduction 4 Package Contents eee een ee eee eee ne ce ee see eeeeeeee 4 Features and Benefits c cccccceceeceeeeeseeeseseeeseeneeeseaseeeseanneeseaeneees 5 Safe ty La oy go 9 fo nee er RT nn 6 Physical COS CUCL ONN cease cece tee eee EERE EEA 8 Basic CONNECTIONS 0 cccceceeeeceeeeneeeeeeeeeneeeeseeeeneesenesseneseeseseenessnnens 11 Product Specification ccccccseseeeeeeeeeseeeeeeneeeceneeeeeneeseanessennessenness 12 2 Accessing Camera 14 If you have DHCP server router in your network ceeee 14 If you do NOT have DHCP server router in your network 14 2 www acti com ACTI Connecting Vision vA KCM 5311 Hardware User s Manual 0 Precautions Read these instructions You should read all the safety and operating instructions before using this product Heed all warnings You must adhere to all the warnings on the product and in the instruction manual Failure to follow the safety instruction given may directly endanger people cause damage to the system or to other equipment Servicing Do not attempt to service this video device yourself as opening or removing covers may expose you to dangerou
2. 5311 Sensor Size ABBA 24MM Minimum Illumination Color 0 1 lux at F1 65 30 IRE 2400 B W 0 05 lux at F1 65 30 IRE 2400 No 1 25 1 2000 sec 50Hz 1 15 1 2000 sec 60Hz manual mode Electronic Shutter 1 1 2000 sec auto mode e Lens Zoom Speed ris is Focus Ato Focus 45 35 1 6 e Video Maximum Frame Rate vs 15 fps at 1920 X 1080 HD 1080p 30 fps at 1280 x 720 HD 720p Resolution H 264 MJPEG 30 fos at 640 x 480 VGA Maximum Frame Rate vs 10 fps at 1920 X 1080 HD 1080p 24 fps at 1280 x 720 HD 720p Resolution MPEG 4 SP 30 fos at 640 x 480 VGA White balance automatic hold and manual Brightness Contrast Automatic gain e Audio Audio Compression 8 kHz Mono PCM 16 bit encoding Audion 3 5mm Phone Jack 3 5mm Phone Jack e Network ean TCP UDP HTTP HTTPS DHCP PPPoE RTP RTSP IPv6 DNS DDNS NTP cia cla ICMP ARP IGMP SMTP FTP UPnP SNMP Bonjour Ethernet Port 1 Ethernet 10 100 Base T RJ 45 connector IP address filtering HTTPS encryption Password protected user levels 12 ACTI Connecting Vision vA KCM 5311 Hardware User s Manual e Alarm Alarm Trigger Video motion detection 3 regions Notify control center Change camera settings Command other devices E mail Alarm Response notification with snapshots Save video or snapshot to local storage Upload video snapshot to FTP server Activate external device through digital
3. com ACTI Connecting Vision vA KCM 5311 Hardware User s Manual 2 Once cables are connected push connector block into the terminal connector on camera FUSE 1A i eo i 0 j DC TO DC CONVERTER 3 sw lt RELAY lt Z siete T O DEVICE O lt LS 2 Serial Port This port connects to serial devices via RS 485 or RS 232 protocols 3 Ethernet Port The IP device connects to the Ethernet via a standard RJ45 connector Supporting NWAY this IP device can auto detect the speed of local network segment 10Base T 100Base TX Ethernet 4 Reset Button Step 1 Switch off IP device by disconnecting the power cable Step 2 Press and continue to hold the Reset Button with a sharp tipped object like a pen Step 3 Reconnect the power cable while continuing to hold the reset button The red Power LED light will flash on for 3 second first turn off for about 15 seconds flash on for another second and turn off again By this time the reset to default operation is already completed This will take around 20 seconds from power up You may then release the reset button This length of time fluctuates slightly with the environment The Power LED light will come back on and stay on after a few more seconds The unit will start up with factory default settings automatically 9 www acti com DA ACTI Connecting Vision KCM 5311 Hardware User s Manual Restore to Default Power
4. On Complete About 20 Seconds 5 Audio Input Output The IP device supports audio input and output with earphone jack 6 Micro SD Micro SDHC Card Slot Insert your Micro SD card here for local recording on camera 7 Power LED This LED light will indicate current camera status 8 Power Input If you use Power Adaptor to run the device please connect the power adaptor to the terminal block in the way shown below Connect v Wire without white stripe to the GND pin Connect wire with white stripe to the 12V pin 10 ACTI Connecting Vision vA KCM 5311 Hardware User s Manual Basic Connections Follow the procedures below to connect the IP device to the respective apparatuses If you have a PoE Power over Ethernet supported switch or injector 1 Connect your IP Box Camera to the Switch Injector by CAT5 or CAT6 cables with RJ45 connector 2 Connect your Switch Injector to PC with another CAT5 CAT6 network cable If your switch does not support PoE and you are powering the camera with power adaptor 1 Connect the power adaptor to IP Box Camera 2 Connect IP device s Ethernet port to Network switch via RJ45 connectors Connect a PC to the Ethernet switch via RJ45 connectors Please refer to our PoE Guide for more details on Power over Ethernet related concepts 1 ACTI Connecting Vision vA KCM 5311 Hardware User s Manual Product Specification ieuo KCM
5. d For the mounting block please attach the flat side towards the front of camera There are two types of mounting blocks and this device uses the black version 4 www acti com ACTI Connecting Vision vA KCM 5311 Hardware User s Manual Features and Benefits This is a cutting edge network video surveillance camera It can capture compress and transmit real time video in excellent quality 15 FPS 2 Megapixel 1920 x 1080 This camera is your best choice to build an intelligent IP surveillance system 35x Zoom Lens with Auto Focus The powerful 35x Zoom Lens with ISP enabled Auto Focus brings precision video quality not available with manual adjustments Focus is no longer an issue during installation saving time while enhancing quality Adaptive Profile With the innovative embedded Image Signal Processor ISP this camera responds to changing lighting condition with customized algorithm This allows for clear image with very little noise at night H 264 MPEG 4 MJPEG Triple Codec Dual Streaming This device supports 3 compression formats H 264 MPEG 4 and MJPEG It brings superior image quality at 15 frames per second in Full HD 1080p 1920 x 1080 In 720p 1280 x 720 and VGA resolution 640 x 480 the device reaches 30 frames per second DC Iris Control With DC Iris Lens this camera automatically adjusts incoming light levels to achieve the best video performance Wildly fluctuating outdoor light
6. duct ask the service technician to perform safety checks to determine if the video product is in proper operating condition 7 www acti com ACTI Connecting Vision gt lt KCM 5311 Hardware User s Manual Physical description eh Digital Input Output 5 Audio Input Output Serial Port MicroSD MicroSDHC Card Slot E Ethernet Port 7 Power LED Reset Button DC 12V Power Input 1 Digital Input Output Used in applications like motion detection event triggering time lapse recording alarm notifications etc the I O terminal connector provides the interface to e 2 Transistor Outputs For connecting external devices such as relays and LEDs Connected devices feos can be activated by Output buttons on the Live View page or through video management software Connect DO1 and DOZ2 to their closest 12V pin to activate e 2 Digital Inputs An alarm input for connecting devices that can toggle between an open and closed circuit for example PIRs door window contacts glass break detectors etc The device will detect the change in digital input and transmit the signal to video surveillance servers The I O terminal pins are numbered right to left Connect input output devices to the camera as follows 1 Attach the cables for the device securely to the supplied green connector block Connect DI pins to GND pins and DO pins to 12V pins Link pins 1 3 2 4 5 7 6 8 8 www acti
7. ing Vision If you are using a single camera this is enough to access the device If you are using multiple devices you need to change the current device to another unused IP address so that when the next device is connected to the network no two devices use the same IP Please perform the following steps 7 Go to Network gt Connection Type 8 Change the IP mode to Static 9 Change the IP to 192 168 0 101 or any other unused IPs Do NOT use the PC s IP address or 192 168 0 100 If this is not the first device you add to the network please also avoid other devices IPs ee ss Web Configurator DA act Host amp Date Link Speed amp Duplex Mode Dynamic IP Address Connection Type Static IP Address IP Address Filtering Pee IP Address 192 _ 168 9 _ 101 DNS DDNS Subnet Mask 255 255 _ 256 _ 0 Port Mapping s Tos ISP Gateway UPap O PPPoE Video amp Audio Maintain al Logout Password E ipve Apply Reset 10 Click Apply 11 Please go to Maintain gt Save amp Reboot and click Apply Internet Explorer will close after a few seconds This is normal 16 ACTI Connecting Vision vA KCM 5311 Hardware User s Manual T erT Web Configurator Host amp Date Host Date amp Time NETWORK Click apply to save all settings and reboot this device Video amp Audio Please wait 30 seconds for system reboot And the window will clase Mai
8. ing condition is no longer an issue with your video quality Powerful Bundled Surveillance Software To extend the capabilities of the IP Box Camera series a powerful surveillance program is included in the package for free Users can easily use an existing PC as a digital video recorder Scheduled recording and manual recording keep every important video recorded in the local hard disk Reliable and accurate motion detection with instant warning enables immediate response in every condition Quick and simple search and playback function lets you easily find the images and video you want 5 www acti com ACTI Connecting Vision vA KCM 5311 Hardware User s Manual Software Development Kit Support This IP Box Camera can be integrated or controlled by applications from third party software developers Software developers can save considerable efforts by using our Streaming Library or ActiveX control Safety Instructions Don t use the power supply with other voltages This device is likely to be damaged or damage other equipments personnel if you use a power supply with different voltage than the one included with this device All warranty of this product will be voided in the situations above Don t open the housing of the product Cleaning Disconnect this video product from the power supply before cleaning Attachments Do not use attachments not recommended by the video product manufacturer as they may cau
9. ntain User Account Setting Systemlnfo Factory Default Firmware Upgrade Profile Pack DA acti Apply Reset Save amp Reboot Logout 12 Wait for 30 seconds and open IE again to connect to the new IP In this example 192 168 0 101 For the second device or more you add into the network please type the correct IP 13 Adjust the default Video setting by going to Video amp Audio gt Media 1 Live Setup Web Configurator p lt ACTi Host BERES E a E NETWORK Link Speed amp Duplex Mode Streaming Mode Single Stream Mode Connection Type Encoder Type H264 w DNS Resolution 1280x720 iv DDNS _ Port Mapping Frame Rate z a0 at Approx 26 FPS Tos Video Bitrate Mode Constant Bit Rate v UPnP Video Max BitRate UNLIMITED shonsa binnan Video BitRate 3M__ Advance Media 1 Media 2 Apply Reset User E Maintain Systeminfo Factory Default Firmware Upgrade Reboot Save amp Reboot Logout 7
10. output e Interface e General Power Source PoE Class 3 IEEE802 3af 6 6W 138 7 mm x 76 mm x 71 4 mm 5 46 x 2 99 x 2 81 OC 50 C 32 F 122 10 85 RH e Integration Unified Solution Fully Compatible with ACTi Software ISV Integration Software Development Kit SDK available Browser Microsoft Internet Explorer 6 0 or newer 3 Pq ACTI KCM 5311 Hardware User s Manual Connecting Vision 2 Accessing Camera If you have DHCP server router in your network Many network server routers are able to automatically provide IP addresses through DHCP If you are using such a network just plug in your computer and IP Box Cam into the network and your IP device will acquire network address by itself Find and access the device with our IP Utility program You may download it at http www acti com product detail Software ACTi_Utility_Suite If you do NOT have DHCP server router in your network 1 Configure your PC to use the same subnet by changing your PC s IP address to the subnet with prefix 192 168 0 XXX The last number should be anything from 1 to 254 except 100 and other occupied IP addresses Subnet mask should be 255 555 255 0 2 The default IP used by this device is 192 168 0 100 Please make sure your PC is NOT using this address and that no two equipments use the same IP address in the network 3 Change your IP address by going to Control Panel gt Manage Network Connec
11. s voltage or other hazards Refer all servicing to qualified service personnel Trademarks All names used in this manual are probably registered trademarks of respective companies Liability Every reasonable care has been taken during the writing of this manual Please inform your local office if you find any inaccuracies or omissions We cannot be held responsible for any typographical or technical errors and reserve the right to make changes to the product and manuals without prior notice FCC CE Regulation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the users will be required to correct the interference at their own expense 3 www acti com ACTI Connecting Vision gt lt KCM 5311 Hardware User s Manual 1 Introduction Package Contents KCM 5311 Power Adaptor Product CD Terminal Blocks for Power DI O and Serial Port oo oo ea Accessories Warranty Car
12. se hazards Water and Moisture Do not use this video product near water for example near a bathtub washbowl kitchen sink or laundry tub in a wet basement or near a swimming pool and the like Don t use accessories not recommended by the manufacturer Only install this device and the power supply in a dry place protected from weather Servicing Do not attempt to service this video product yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel Damage Requiring service Disconnect this video product from the power supply immediately and refer servicing to qualified service personnel under the following conditions 6 www acti com ACTI Connecting Vision vA KCM 5311 Hardware User s Manual ss When the power supply cord or plug is damaged If liquid has been spilled or objects have fallen into the video product 2 3 Ifthe video product has been directly exposed to rain or water 4 Ifthe video product does not operate normally by following the operating Instructions in this manual Adjust only those controls that are covered by the instruction manual as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the video product to its normal operation Safety Check Upon completion of any service or repairs to this video pro
13. tions gt Right click on the connection to change gt Option gt TCP IP IPv4 Properties ajx General You can get IP settings assigned automatically f your network supports thes capability Othermise you need to ask your network administrator for Please set the settings as below the appropriate IP settings C Obtain an IP addess automatically Uey he lolong Wades IP address 192 168 0 xxx IP address Staat naii Subnet mask 255 255 255 Default gateway 0 fa NOTE xxx should be a number from 1 to 254 except 100 which is Use the following DNS server addresses Prefered DNS server Afermate ONS server used by the IP device Please also make sure that no two equipments use the same IP address in the 1a pe ACTI Connecting Vision KCM 5311 Hardware User s Manual 4 Open Internet Explorer Version 6 0 or above and type in the Default IP 192 168 0 100 5 When you see the login window please input default user and password Default User Admin Password 123456 Web Configurator Account Admin Password seses Language English 6 After logging in you will see the video from camera To go to the main menu click the Setup button on the top left CT ee Web Configurator ro ACTi Function Media Encoder Type Size E a a 1 ne o 5 Pq ACTI KCM 5311 Hardware User s Manual Connect