Home
“USER`S MANUAL AND OPERATING INSTRUCTIONS”
Contents
1. INDOOR OUTDOOR PRODUCTS KEROSENE PORTABLE FORCED AIR HEATERS USER S MANUAL AND OPERATING INSTRUCTIONS B COMPLIES WITH ANSI A10 10 1998 CAN CSA B140 0 03 AND CSA B140 8 1967 race ELUNE mo MODEL KFA400DGD Before the first use of this heater please read this USER S MANUAL very carefully This USER S MANUAL has been designed to instruct you as to the proper manner in which to assemble maintain store and most importantly how to operate the heater in a safe and efficient manner Please keep this manual for future reference CONSUMER Retain this manual for future reference Questions problems missing parts Before returning to your retailer call our customer service department at 877 447 4768 8 30 a m 4 30 pm CST Monday Friday or email us at customerservice ghpgroupinc com IMKFA400DG GCU NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING A DANGER IMPROPER USE OF THIS HEATER CAN RESULT IN SERIOUS INJURY OR DEATH FROM BURNS FIRE EXPLOSION ELECTRICAL SHOCK AND OR CARBON MONOXIDE POISONING A WARNINGS 1 RISK OF INDOOR AIR POLLUTION Use this heater only in well ventilated areas Provide at least a three square foot 2 800 sq cm opening of fresh outside air for each 100 000 BTU hr of heater rating e People with breathing problems should consult a physician before using the heater Carbon monoxid
2. NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 3 UNPACKING AND ASSEMBLY 1 REMOVE THE HEATER AND ALL PACKING MATERIALS FROM THE BOX See Fig 2 NOTE Save the shipping carton and packing materials for future storage Screw L Wheels Cord Wrap Cap Nuts L Bushings Washers Cap Nuts S OG 9888 Hardware Kit Part No HW KFA1019 Handle Wheel Support Frame Threaded Axle Figure 2 PACKING MATERIALS 2 ASSEMBLING Tools Required e Medium Phillips Screwdriver 24mm Socket Wrench Assembling wheel amp handle amp cord wrap 1 Slide threaded axle through the rear sectioon of the wheel support frame 2 Slide one axle bushing on to each side of the axle Slide one wheel on to each side of the axle Attach one cap nut on to each side of the threaded axle and tighten well 3 Place heater on wheel support frame Make sure air inlet end rear of heater is over wheels Align the holes on fuel tank flange Insert screws L through handles front and Rear fuel tank flange and wheel support frame Insert screws S through rear handle fuel tank flange and washer S as shown in figure 3 and attach nut finger tight after each screw is inserted 4 After all screws are inserted tighten nuts firmly 5 Align the hole on the rear handle with the mounting hole on the cord wrap 6 Insert screws through cord wrap rear handle as shown in Figure 3 and attach nut finger tight after each screw is inserted 7 Aft
3. 17 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 14 EXPLODED PARTS DRAWING KFA400DGD MODEL NOTE SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS 14 7 18 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 15 PARTS LIST DESCRIPTION PART No KFA400DGD Quantity Fuel Tank Assembly 2151 0010 00 Fuel Drain Bolt 4329 0072 00 Fuel Gauge 2156 0053 00 Fuel Filter 322 1 0009 00 Fuel Cap 2151 0041 00 Filler Neck Assembly 2155 0007 00 Space Support 3713 0004 00 Card Support 3713 0016 00 O 00 NY ON IB Go RO Cord Bushing 3712 0013 00 Power Cord 3980 0268 00 Bushing Grommet L 3231 0121 00 Shell Lower 3111 0195 08 Bushing Grommet S 323 1 0120 00 Flange Screw 4319 00 15 00 Line Fuel 3740 003 1 00 Harness Burner 39D0 078 1 00 Cone Ouside 2153 0012 01 Clip Nut 3131 0182 00 Chamber Assembly 2152 0037 00 Air Deflector 3131 0306 00 Air Deflector 3131 0307 00 Burner Head Assembly 2152 0058 00 Bracket Photocell 3131 0159 00 Screw BH1 43 11 0068 00 Photocell 2153 0007 00 Temperature Limit 38C0 0032 00 Screw PH2 43 12 002 1 00 Igniter 39E0 002 1 00 Cover Igniter 3131 0309 01 Motor amp Pump Assembly 2154 0025
4. 14 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 11 TROUBLE SHOOTING GUIDE device is overheated TROUBLE POSSIBLE CAUSE CORRECTIVE ACTION Heater ignites but MAIN PCB 1 Wrong pump pressure 1 See Pump Pressure Adjustment assembly shuts heater off after 2 Dirty Fuel Filter page 13 a short period of time 3 Dirt in Nozzle 2 See Fuel Filter page 12 Indicator lamp is flickering and 4 Dirty Photocell Lens 3 See Nozzle page 10 room temp display indicates EP 5 Photocell Assembly not 4 Clean Photocell Lens page 11 properly installed Not 5 Make sure photocell boot is seeing the flame properly seated in bracket 6 Bad electrical connection See page 11 between photocell and MAIN 6 Check electrical connections PCB assembly See wiring diagram page 15 7 Defective photocell 7 Replace photocell page 11 8 Temperature limit safety 8 Turn operating switch to OFF and allow to cool about 10 min Then turn operating switch to ON position Heater will not ignite but motor runs for a short period of time Indicator lamp is flickering and room temp display indicates E1 1 No fuel in tank Wrong pump pressure Carbon deposits on spark plug and or improper gap Dirty fuel filter Dirt in nozzle Water in fuel tank Bad electrical connection between ignitor and MAIN PCB assembly 8 Ignitor wire is not attached to spark plug 9 Defective ignitor 10 Defective solen
5. Disconnect fuel line B from pumpand pump fuel filter assembly with3 8 wrench See Figure 14 Remove two screws that fix bracket filter to shell lower and remove bracket filter Carefully pry fuel filter loose from fueltank with flat end of screwdriver Wash fuel lines and fuel filter with clean SHELL LOWER kerosene BRACKET FILTER Replace fuel filter into fuel tank PUMP FUEL FILTER ASSEMBLY Replace bracket filter to shell lower FUEL LINE B Connect fuel lines B to pump and pump fuel filter assembly Reinstall fan guard FUEL FILTE Figure 14 Remove Tank Fuel Filter Pump Fuel Filter Remove fan guard See page 11 Unscrew C W filter bottom from filter top with adjustble pliers Remove fuel filter gasket magnet from filter LAE FILTER TOP bottom See Figure 15 Wash filter bottom with clean kerosene Wipe inside of filter bottom dry with clean cloth Dy AS UEL FILTER Wash Fuel filter in clean kerosene GASKET Remove dirt attached magnet PONET Put clean magnet fuel filter and gasket back in LTER BOTTOM filter bottom Tighten firmly Figure 15 Fuel Pump Filter 12 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING H PUMP PRESSURE ADJUSTIMENT Remove pressure gauge plug from pump with 1 8 allen wrench Install accessory pressure gauge to pressure gauge port See Figure 16 Start heater See operation page 6 A
6. use 8 AWG conductor e 401 to 500 feet long use 6 AWG conductor 4 Turn Thermostat Control Knob to desired setting setting range 40 F 110 F and push operating switch to ON position power indicator lamp and room temp display will light and heater will start NOTE Room Temp display indicates as following When room temp is less than 0 F Lo e When room temp is between 0 Fand 99 F Indicates in figure e When room temp is more than 99 F Hi If heater does not start the thermostat setting may be too low turn THERMOSTATCONTROL Knob to higher position to start heater If heater still does not start turn operating switch to OFF and then to ON position Figure 4 If heater still does not start see Troubleshooting Guide on page 13 INDICATOR LAMP OPERATING SWITCH ROOM TEMP DISPLAY THERMOSTAT CONTROL KNOB Figure 4 CONTROL PARTS NOTICE The major electrical components of this heater are protected by a safety fuse mounted to the PCB board If your heater fails to start check this fuse first and replace as necessary You should also check your power source to insure that proper voltage and frequency are being supplied to the heater NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING TO STOP HEATER A CAUTION Never unplug heater while heater is running Heater must go through cooling cycle The cooling cycle cools the combustion chamber Damage to heater can occur if co
7. 3302
8. CONTENTS OF USER S MANUAL PRECAUTIONS SAFETY GUIDE CO DY OP a Re NAPRWNrR OC INTRODUCTION wea task bas IA A ATURES PEPPE Lea shed causa UNPACKING AND ASSEMBLV l K OR NO 1 FUEL OIL PP cba TT OVERVIEW OF HEATER DESIGN TAT A TE Sa AW ORT Shs TFT FUELING YOUR HEATER OPERATION A A A A LONG TERM STORAGE OF YOUR HEATER er rspeeesnnssente kti tinitbekza arnznnznettabsevanzanake te MAINTENANCE TA TATNA REPLACING FUSE Dadiebap sags bus ETA Ta TROUBLE SHOOTING GUIDE idea TET cule ta dies WIRING DIAGRAM A SPECIFICATIONS PA A A A ONE ATA EXPLODED PARTS DRAWING a ta i aa BRE sald E e TE PARTS LIST io eee doi iy eet INTRODUCTION Please read this USER S MANUAL carefully It will show you how to assemble maintain and operate the heater safely and efficiently to obtain full benefits from its many built in features FEATURES Handle Upper Shell Fan Guard uel Tank Thermostot Knob y Fuel Drain Bolt Room Temp Display Operating Switch Power Cord Piggy Back Figure 1 KFA400DGD MODEL 2 ONMNNABWN o
9. air deflectors using a soft cloth moistened with kerosene or solvent Dry fan blades and air deflectors thoroughly Reinstall upper shell FAN BLADE Figure 8 Fan Blades and Air Deflectors NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING C SPARK PLUG SPARK PLUG CLEAN AND REGAP EVERY 600 HOURS BURNER HEAD OPERATION OR REPLACE AS NEEDED Remove upper shell See page 9 SPARK PLUG WIRE Remove spark plug wire from spark plug See Figure 9 Remove spark plug from burner head using medium phillips screw driver Clean and regap spark plug electrodes to 0 14 3 5mm gap Reinstall spark plug in burner head Attach spark plug wire to spark plug Reinstall upper shell D NOZZLE REMOVE DIRT IN NOZZLE AS NEED See page 14 Remove upper shell See page 9 Remove fuel line from solenoid valve using 1 4 wrench Remove spark plug wire from spark plug Remove spark plug from burner head using medium phillips screw driver Remove five screws using medium phillips screwdriver and remove burner head from combustion chamber Figure 9 Spark Plug Carefully remove nozzle from burner head NOZZLE FOACE SPARK PLUG using 5 8 socket wrench Blow compressed air through face of nozzle SPARK PLUG WIRE this will remove any dir in nozzle Inspect nozzle for damage If damaged or clogged replace nozzle Make sure plug is in place on burner head Reinstall nozzle into
10. 00 P C B Assembly 215A 0075 00 Cover Displav 3121 0587 04 Window Displav 3231 0113 00 Operating Switch 39 A0 0209 00 Fuse Holder 3930 0012 00 Fuse 3920 0061 00 Safe Guard Assemblv 2153 0011 01 Bracket Filter 3131 0465 00 Mesh Guard 3121 0336 01 Impeller Washer 3131 0240 00 Fan Assembly 2154 0021 00 Bolt Standard Socket 4323 0005 00 Shell Upper 3111 0196 08 FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR CONTACT US AT Phone 1 877 447 4768 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 15 PARTS LIST BURNER HEAD ASSEMBLY amp MOTOR AND PUMP ASSEMBLY NOTE SPECIFY MODEL NUMBER AND PART NUMBER WHEN DRDERING PARTS DESCRIPTION PART NO Burner Head 3531 0012 00 Plug 3541 0060 00 Nozzle SP KFA1024 Spark Plug SP KFA1009 Fiber Washer 4349 0017 00 Spring Washer 4342 0009 00 Flange Bolt 4329 0013 00 Nipple Straight 3541 0057 00 Solenoid Valve 39 0 0084 00 Elbow Male 3740 0037 00 KEV NO DESCRIPTION PARTNO 1 Motor 3970 0081 00 2 Supportor Motor 3121 0334 00 3 Bolt HH 4321 0182 00 4 Nut Lock 4331 0022 00 5 Coupling Pump 3531 0013 00 6 Gear Pump 3740 0026 00 7 Bolt Headless Socket 4323 0004 00 8 Filter Oil Assembly 3740 0034 00 9 Elbow Male 3740 0044 00 10 Fitt
11. CHASER IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE THE REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES IN NO EVENT WILL GHP GROUP INC BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you CLAIMS HANDLED AS FOLLOWS 1 Contact your retailer and explain the problem 2 Ifthe retailer is unable to resolve the problem contact our Customer Service Dept detailing the heater model the problem and proof of date of purchase 3 Arepresentative will contact you DO NOT RETURN THE HEATER TO GHP GROUP INC unless instructed by our Representative This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO REGISTER THE WARRANTY ON YOUR HEATER PLEASE FILL OUT THIS CARD COMPLETELY AND MAIL WITHIN 14 DAYS FROM DATE OF PURCHASE OR REGISTER ON LINE AT www ghpgroupinc com NAME PHONE EMAIL ADDRESS CITY STATE ZIP MODEL SERIAL DATE PURCHASED DEALER PURCHASED FROM TYPE OF STORE CITY amp STATE WHERE PURCHASED PRICE PAID Please Take a M
12. ROL PCB POWER LAMP LED THERMOSTAT TEMP CONTROL 5 CN8 RED LIMIT CONTROL BLACK 6 BLACK WHITE BLACK SPARK PLUG WHIT a J BLACK ORANGE BLACK PUMP RED MOTOR WHITE CAPACITOR CN2 AC2 WHT 45uF 400Vac CN1 AC1 BLK CN6 WHITE VELI WHITE VELI PHOTOCELL OPERATING SWITCH POWER PLUG AC120V 6 OHz EARTH FUSE 20A 250VAC 16 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 13 SPECIFICATIONS BARI One 50 te Mes QO 590 RY OS ae x x 5 KO 555 O we 9 a 4 0 f 4 5 5 9 5 5 55 55 KW XY 220 0404 Lo ASA H 0 5555 B e 5 552525255222 fel rm gt 552555522 4 le Fi 22 32 8 X tir a WA ja 52 5 31 4 KFA400DGD MODEL KFA400DGD BTU Hr 400 000 Fuel Consumption Gal Hr 3 0 11 36 Fuel Tank Capacitv Gal 2 29 01 10 0 Pump Pressure PSI kgf 125 8 79 Volts Hz Amps 120VAC 60 4 4 Phase 1 Size D x W xH Inch mm 52 5 x 31 4 x 32 8 1 334 x 798 x 834 Weight Ibs kg 150 68 0
13. VER mix water with the kerosene as it will cause rust inside the tank Pour the kerosene out making sure that you remove it all IMPORTANT Do not store kerosene over summer months for use during next heating season Using old fuel could damage heater 3 Reinstall Fuel Drain Bolt to Fuel tank and tighten firmly using 3 4 socket or adjustable wrench Fuel Drain Bolt Figure 6 Drain Bolt IMPORTANT Before reinstalling the fuel drain bolt make sure the seal is on the bolt If the seal is not used the bolt cannot be installed correctly and the fuel tank will leak 4 Store heater in dry well ventilated area Make sure storage place is free of dust and corrosive fumes 5 Store the heater in the original box with the original packing material and keep the USER S MANUAL with the heater NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 9 MAINTENANCE WARNING NEVER SERVICE HEATER WHILE IT IS PLUGGED IN OR WHILE HOT USE ORIGINAL EQUIPMENT REPLACEMENT PARTS Use of third party or other alternate components will void warranty and may cause unsafe operating conditions A UPPER SHELL REMOVAL Screw Shell Upper Remove screws along each side and top of heater using medium phillips screw driver Lift upper shell off See Figure 7 Figure 7 Upper Shell Removal B FAN BLADES AND AIR DEFLECTOR ANNE SA CLEAN EVERY SEASON OR AS NEEDED Remove upper shell See figure 7 above Clean fan blades and
14. amp stove fuel paint thinners or other oil compounds in this heater These are volatile fuels that can cause an explosion or uncontrolled flames NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 5 OVERVIEW OF HEATERS DESIGN Fuel System This heater is equipped with a Fuel pump Gear that pulls fuel through the fuel line connected to the fuel tank and then pushes fuel through a filter and a solenoid valve and out the burner head nozzle This fuel is sprayed into the combustion chamber in a fine mist Sure Fire Ignition The electronic ignitor sends voltage to a specially designed spark plug The spark plug ignites the fuel and air mixture The Air System The heavy duty motor turns a fan that forces air into and around the combustion chamber This air is heated and then forced out the front of the heater The Saf m A Temperature Limit Control This heater is equipped with a Temperature Limit Control designed to turn off the heater should the internal temperature rise to an unsafe level If this device activates and turns your heater off it may require service Internal Shut Off Temp Reset Temperature Plus Minus 10 Degrees Plus Minus 10 Degrees 176 F 80 C 122 F 50 C B Electrical System Protection This heaters electrical system is protected by a fuse mounted to the PCB assembly that protects it and other elec
15. animals away from heater Bulk fuel storage should be a minimum of 25 ft from heaters torches portable generators or other sources of ignition All fuel storage should be in accordance with federal state or local authorities having jurisdiction 3 RISK OF ELECTRIC SHOCK Use only the electrical power voltage and frequency specified on the model plate of the heater e Use only a three prong grounded outlet and extension cord e ALWAYS install the heater so that it is not directly exposed to water spray rain dripping water or wind e ALWAYS unplug the heater when not in use PROPOSITION 65 WARNING Fuels used in gas wood burning or oil fired appliances and the products of combustion of such fuels contain chemicals known to the State of California to cause cancer birth defects and other reproductive harm MASSACHUSETTS RESIDENTS Massachusetts state law prohibits the use of this heater in any building which is used in whole or in part for human habitation Use of this heating device in Massachusetts requires local fire dept permit M E L C 148 Section 10A CANADIAN RESIDENTS Use of this heater shall be in accordance with authorities having jurisdiction and CSA Standard B139 NEW YORK CITY RESIDENTS For use only at construction sites in accordance with applicable NYC codes under NYCFD certificate of approval 5034 and 5037 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING ITEM
16. burned head and tighten firmly 175 200 inch pounds Reinstall spark plug in burner head SOLENOIO VALUE Attach burner head to combustion chamber FUEL LINE Attach spark plug wire to spark plug Attach fuel line to solenoid valve tighten firmly Replace upper shell Figure 10 NOZZLE 10 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING E PHOTOCELL CLEAN PHOTO CELL ANNUALLY OR AS NEEDED Remove upper shell See Page 9 Remove photocell from photocell Bracket and disconnect photocell from connector Clean photocell lens with cotton swab Inspect photcell lens for damage If damaged replace photocell PHOTOCELL BRACKET PHOTOCELL 1 INCORRECT l A Sts 2 CORRECT Figure 11 Clean photocell Lens F FUEL LINES TIGHTENING FUEL LINES ANNUALLY OR AS NEEDED Remove upper shell See page 9 Use 1 4 wrench and tighten fuel lines A at solenoid valve and at pump See Figure 12 Remove fan guard See Figure 13 Use 3 8 wrench and tighten fuel lines B at pump pump fuel filter assembly Reinstall fan guard BURNER HEAD FAN GUARD SOLENOID VALVE FUEL LINE A FLAT WASHER SCREW Figure 12 Tighten fuel line Figure 13 Remove Fan guard 11 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING G FUEL FILTER CLEAN TWICE PER HEATING SEASON OR AS NEEDED s Tank Fuel Filter Remove fan guard See Figure 11
17. e poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness and or nausea If you have these signs the heater may not be working properly Get fresh air at once Have the heater serviced Some people are more affected by carbon monoxide than others These include pregnant women persons with heart or lung disease or anemia those under the influence of alcohol or those at high altitudes e Never use this heater in living or sleeping areas 2 RISK OF BURNS FIRE EXPLOSION e NEVER use any fuel other than l K kerosene 1 disel fuel oil in this heater e NEVER use fuel such as gasoline benzene paint thinners or other oil compounds in this heater RISK OF FIRE OR EXPLOSION NEVER use this heater where flammable vapors may be present e NEVER refill the heaters fuel tank while heater is operating or is still hot A CAUTION Hot while in operation Do not touch Keep children clothing and combustibles away from heater Minimum Clearances Outlet 8 feet 250cm Sides top and rear 4 feet 125cm NEVER block air inlet rear or air outlet front of heater NEVER use duct work in front or behind of heater NEVER move handle service a hot operating or plugged in heater NEVER transport heater with fuel in it s tank When used with an optional thermostat or if equipped with a thermostat heater may start at any time ALWAYS locate heater on a stable and level surface ALWAYS keep children and
18. er all screws are inserted tighten nuts firmly A CAUTION DO NOT OPERATE heater without support frame assembled to tank NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING Handle Fuel Tank Flange Wheel Support Wheel Nut Nut L Figure 3 Assembling Handle amp Wheel and Cord wrap 4 KEROSENE 1 K For optimal performance of this heater it is strongly suggested that l K kerosene be used l K kerosene has been refined to virtually eliminate contaminants such as sulpher Which can cause a rotten egg odor during the operation of the heater However 1 diesel fuel oil may also be used if 1 K kerosene is not available Be advised that these fuels do not burn as clean as l K kerosene and care should be taken to provide more fresh air ventilation to accomodate any added contaminants that may be added to the heated space KEROSENE SHOULD ONLY BE STORED INA BLUE CONTAINER THAT IS CLEARLY MARKED KEROSENE NEVER STORE KEROSENE IN A RED CONTAINER Red containers are associated with gasoline living area NEVER use any fuel other than l K kerosene 1 fuel oil is an acceptable substitute NEVER store kerosene in direct sunlight or near a source of heat OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NEVER store kerosene in the living space Kerosene should be stored in a well ventilated place outside the NEVER use fuel such as gasoline benzene alcohol white gas c
19. ing Straight 3740 0039 00 11 Holder Condensor 3131 0295 00 12 Bushing Grommet 3712 0004 00 13 Cover Condensor 3121 0338 00 14 Flange Screw 4319 0015 00 15 Capacitor 3820 0144 00 20 Figure 18 Burner Head Assemblv Figure 19 Motor and Pump Assembly NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 15 PARTS LIST Wheel and Handle NOTE SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS DESCRIPTION PART NO Wheel Support Frame 3551 0098 00 Handle 3551 0036 00 Cord Wrap 3221 0052 00 Threaded Axle 3541 0096 00 Wheel 3720 0004 00 Hardware Kit HW KFA1019 Screw L INCLUDED IN HARDWARE KI Screw S INCLUDED IN HARDWARE KI Nut INCLUDED IN HARDWARE KI Cap Nut S INCLUDED IN HARDWARE KI Bushing INCLUDED IN HARDWARE KI Flat Washer INCLUDED IN HARDWARE KI Cap Nut L INCLUDED IN HARDWARE KI N IN IN A Aa ID IN Warranty LIMITED WARRANTY This limited warranty is extended to the original retail purchaser of this Forced Air Convection Radiant Heater and warrants against any defect in materials and workmanship for a period of one 1 year from the date of retail sale GHP Group Inc at it s option will either provide replacement parts or replace or repair the unit when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group Inc within one 1 year of retail purchase Sh
20. inute To Give Us Your Answers To The Following Questions All Responses Are Used Solely For Market Research And Are Held In Strict Confidence Who primarily decided this purchase O Male LI Female 0 18 24 O 25 39 040 59 C 60 and over Purpose of Purchase Do you own any other portable heaters CI Yes LI No If yes type brand How do you intend to use your new heater DI Construction Site 0 Farm Warehouse Commercial DI Garage Outbuilding DI Other How did you become aware of this heater In Store Display NewspaperAd Magazine Ad Friend Relative TV Commercial DI Store Salesperson LI Other What made you select this heater DI Style Size Portability Price Package Brand Other Do you O own LI rent Would you recommend this heater to a friend Yes Please give us your comments THANK YOU FOR COMPLETING THIS FORM Information will be held confidential WARRANTV REGISTRATION IMPORTANT We urge vou to fill out vour warrantv registration card within fourteen 14 davs of date of purchase Vou can also register vour warrantv on the internet at www ghpgroupinc com Complete the entire serial number Retain this portion of the card for vour records GHP Group Inc 6440 W Howard St Niles IL 60714 3302 Tel 877 447 4768 www ghpgroupinc com SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 6440 W Howard St Niles IL 60714
21. ipping costs labour costs etc are the responsibility of the purchaser DUTIES OF THE OWNER This heating appliance must be operated in accordance with the written instructions furnished with this heater This warranty shall not excuse the owner from properly maintaining this heater in accordance with the written instructions furnished with this heater A bill of sale canceled check or payment record must be kept to verify purchase date and establish warranty period Original carton should be kept in case of warranty return of unit WHAT IS NOT COVERED 1 Damage resulting from use of improper fuel Damage caused by misuse or use contrary to the owners manual and safety guidelines Damage caused by a lack of normal maintenance Fuses Use of non standard parts or accessories Damage caused in transit Freight charges on warranty parts or heaters to and from the factory shall be the responsibility of the owner gt This warranty does not imply or assume any responsibility for consequential damages that may result from the use misuse or the lack of routine maintenance of this heating appliance A cleaning fee and the cost of parts may be charged for appliance failures resulting from lack of maintenance This warranty does not cover claims which do not involve defective workmanship or materials FAILURE TO PERFORM GENERAL MAINTENANCE INCLUDING CLEANING WILL VOID THIS WARRANTY THIS LIMITED WARRANTY IS GIVEN TO THE PUR
22. llow motor to reach full speed Adjust pressure Using a small flat blade screw driver Turn pressure adj Screw to clock wise to increase pressure Turn screw to counter clock wise to decrease pressure Set pump pressure to 125 PSI Stop heater See operation page 6 Remove pressure gauge Replace pressure gauge plug in pressure gauge port PRESSURE GAUGE PORT PRESSURE GAUGE PLUG PRESSURE GAUGE Figure 16 Adjusting Pump Pressure NOTE USE ONLY ORIGINAL EQUIPMENT REPLACEMENT PARTS USE OF ALTERNATE OR THIRD PARTY COMPONENTS WILL VOID ANY WARRANTY AND MAY CAUSE UNSAFE OPERATING CONDITION 13 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 10 REPLACING FUSE NOTICE This heater is fuse protected If your heater fails to ignite DO NOT RETURN YOUR HEATER TO THE STORE Please follow the simple instruction below to inspect and change the fuse PROCEDURE FOR REPLACING FUSE A WARNING SHOCK HAZARD To prevent personal injury unplug the power cord before replacing fuse 1 Unplug heater 2 Turn Fuse Cover COUNTERCLOCKWISE 45 using a flat blade screwdriver and remove Fuse from Fuse Holder 3 Replace Fuse with enclosed fuse A WARNING FIRE HAZARD To avoid fire Do not substitute with a higher or lower current rating 4 Turn Fuse Cover CLOCKWISE 45 using a flat blade screwdriver while slightly pushing NOTE Specified fuse rating 250VAC 20A Fuse Holder Figure 17 Replacing Fuse
23. mbustion chamber is not cooled Do not restart heater until cooling cycle is complete Turn operating switch to OFF This will cause heater flame to go out The motor will continue to run during the cooling cycle Room Temp Display will show CC during the cooling cycle This allows the fan to cool the combustion chamber When the cooling cycle 1 is finished the motor will stop Do not unplug heater until cooling cycle is finished 2 Unplug power cord 3 To temporarily stop heaters set thermostat at a temperature lower than air around heater Heater will cycle back on if air temperature around heater matches thermostat setting TO RESTART HEATER A CAUTION Do not restart heater until cooling cycle is finished The cooling cycle cools the combustion chamber 1 Wait until cooling cycle is finished after stopping heater 2 Repeat steps under to start HEATER PIGGYBACK POWER CORD COVER ELECTRIC OUTLET Figure 5 Piggyback Power Cord WARNING SHOCK HAZARD e Always cover electric outlet when not in use Do not plug in and use an appliance of more than 120V 5A current in this outlet NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 8 LONG TERM STORAGE OF YOUR HEATER 1 Remove fuel drain bolt from rear bottom side of fuel tank using 3 4 socket or adjustable wrench and drain 2 Using a small amount of kerosene swirl and rinse the inside of the tank NE
24. oid valve not opening wr SLOVO 1 Fill tank with kerosene 2 See Pump Pressure Adjustment page 13 See Spark Plug page 10 See Fuel Filter page 12 See Nozzle page 10 Flush fuel tank with clean kerosene page 9 Check electrical connections See wiring diagram page 15 8 Attach ignitor wire to spark plug See Spark Plug page 10 9 Replace ignitor 10 Check electrical connections and voltage to solenoid valve If defective replace solenoid valve Fan does not turn when heater is plugged in and operating switch was in the ON position Indicator lamp is on or flickering Indicator lamp is flickering and room temp display indicates E2 Indicator lamp is flickering and room temp display indicates 1 Thermostat setting is too low 2 Bad electrical connection between motor and MAIN PCB assembly 1 Thermostat switch failure 1 Turn thermostat control knob to a higher setting 2 Check electrical connections See Wiring Diagram page 15 1 Replace sensor See wiring diagram page 15 1 Replace switch See wiring diagram page 15 Heater will not turn on Indicator lamp is off 1 No electrical power 2 Blown fuse 1 Check to insure heater cord and extension cord are plugged in Check power supply 2 Replace safety fuse on cover display 15 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 12 WIRING DIAGRAM CONT
25. trical components from damage If your heater fails to operate check this fuse first and replace as needed FUSE TYPE 250 VAC 8 amps C Flame Out Sensor Utilizes a photocell to monitor the flame in burn chamber during normal operation It will cause the heater to shut off should the burner flame extinguish 6 FUELING YOUR HEATER NEVER FILL THE HEATER FUEL TANK IN THE LIVING SPACE FILL THE TANK OUTDOORS DO NOT OVERFILL YOUR HEATER AND BE SURE HEATER IS LEVELED IMPORTANT NOTICE REGARDING FIRST IGNITION OF HEATER The first time you light the heater it should be done outdoors This allows the oils etc used in manufacturing the heater to burn off outside A WARNING NEVER REFILL HEATER FUEL TANK WHEN HEATER IS OPERATING OR STILL HOT NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 7 OPERATION A VENTILATION RISK OF INDOOR AIR POLLUTION USE HEATER ONLY IN WELL VENTILATED AREAS Provide at least a three square foot 2 800 sq cm opening of fresh outside air for each 100 000 BTU hr of heater rating B OPERATION TO START HEATER 1 Fill fuel tank with kerosene or No 1 fuel oil 2 Attach fuel cap 3 Plug power cord of heater into three prong grounded extension cord Extension cord must be at least six feet long Extension Cord Wire Size Requirements e 6 to 100 feet long use 14 AWG conductor e 101 to 200 feet long use 12 AWG conductor 201 to 300 feet long use 10 AWG conductor 301 to 400 feet long
Download Pdf Manuals
Related Search
Related Contents
R-64ST - CONRAD Produktinfo. SE 600 Series User Manual CAL Controls CALogix Programming and Installation Manual 33087 American Standard 8630 Series User's Manual LAMPOCICLO OEM Manuale d`uso rev 9 IT APC BR1300LCD Power Supply User Manual Kenmore 790.9634 Range User Manual T95045T1 User Manual Copyright © All rights reserved.