1. External Antenna Mag Mount Base Station in cab NOT TO SCALE AUTOGUARD Wireless Intrusion Detection System User Manual Page 2 AUTOGUARD AUTOGUARD Wireless Intrusion Detection System User Manual Intrusion Detection www cvigil co uk C VIGIL Ltd transport support cvigil co uk User Manual Page 3 AUTOGUARD Lontents SVSTEM EN ET 4 L gt Detertor Hals sasssa 4 VA eee een eee ak 4 LZ DREG ON VIRES 2 vee 5 725 TCR 7 6 121 Benea as sk Die Ling 6 122 UNM UES sk a A 6 129 System Cade Transmission E Settings rennur eneste 7 124 SPAR LL LUI IE 7 2 OPERATION amp DEPLOYMENT 8 21 hana ss eot co dE re 8 22 Detector uos 8 23 Receiver 9 2 DETECTOR BATTERY ENDURANCE 9 Intrusion Detection www cvigil co uk C VIGIL Ltd transport support cvigil co uk User Manual 4 AUTOGUARD System Description 11 Detector Heads General Each detector head is a self contained battery powered unit capable of transmitting a coded alarm signal to the central monitoring station An
2. 1 Alarm 24h 5461 14 96 Days Years 2 Alarms 24h 5323 14 58 Days Years 10 Alarms 24h 4431 12 14 Days Years 24 Alarms 24h 3443 9 43 Intrusion Detection www cvigil co uk C VIGIL Ltd transport support cvigil co uk AUTOGUARD User Manual 10 AUTOGUARD Wireless Intrusion Detection System Schematics Intrusion Detection www cvigil co uk C VIGIL Ltd transport support cvigil co uk C VIGIL Espor DEPLOYMENT EXAMPLE LEFT SIDE RIGHT SIDE REAR NOT TO SCALE E VIGIE AutoGuard Transport TRAILER RIGHT TRAILER RIGHT TRAILER LEFT TRAILER LEFT CAB RIGHT FRONT REAR CAB LEFT FRONT REAR TRAILER REAR CAB FRONT Wireless Link External Antenna Mag Mount Base Station in cab NOT TO SCALE E VIGIE WIRELESS PIR MOTION SENSOR NOT TO SCALE C VIGIL WIRELESS PIR MOTION SENSOR NOT TO SCALE CE RECEIVER BASE STATION r Audible Alarm Off Constant Q Pulsed O O O O O O O O O NOT TO SCALE CE RECEIVER BASE STATION 260mm NOT TO SCALE EXTERNAL ANTENNA NOT TO SCALE sport EXTERNAL ANTENNA Nylock 66mm NOT TO SCALE
3. C VIGIE AUTOGUARD INTRUSION DETECTION Registered in England amp Wales Digital House Peak Business Park Foxwood Rd Company Registration No 04407624 Chesterfield Derbyshire 541 9RF UK Registration GB 804 6004 68 SN S Swbd 44 0 8432 898 464 ISO 9001 2008 Registration No GB 2001654 D T 44 0 1246 269 469 F 44 0 1246 351 288 www cvigil co uk C VIGIL Ltd transport E info cvigil co uk C VIGIE AUTOGUARD INTRUSION DETECTION INTRODUCTION High Risk Areas Strategically placed wireless PIR motion detectors will alert the driver to possible intrusions without exposing him her to unnecessary risks Port Area Security Detect unwanted guests who try to gain access to your vehicle Protect the relatively exposed trailer section Stowaway Prevention Detect personnel approaching the vehicle with the intent to gain un authorised access AUTOGUARD COMPRISES Receiver Base Station e Wireless Detector Heads Sided Carry Storage Case e External Antenna Coax Cable Mounting 5 Mag Mounts Bungee Cord Mounts User Manual Mains Cable C VIGIL Espor DEPLOYMENT EXAMPLE LEFT SIDE RIGHT SIDE REAR NOT TO SCALE E VIGIE AutoGuard Transport TRAILER RIGHT TRAILER RIGHT TRAILER LEFT TRAILER LEFT CAB RIGHT FRONT REAR CAB LEFT FRONT REAR TRAILER REAR CAB FRONT Wireless Link
4. e the cover to be replaced to reset the detector Intrusion Detection www cvigil co uk C VIGIL Ltd transport support Qcvigil co uk User Manual 5 AUTOGUARD LZ Detection Zones The detection zones are indicated in the diagrams below 2m 2 4 48 30m Detection Zone Side View 3m 3m 30m Detection Zone Plan View Intrusian Detection www cvigil co uk C VIGIL Ltd transport support cvigil co uk 12 121 122 User Manual AUTOGUARD Receiver Base Station General AUTOGUARD The unit is lightweight and is intended for mains operation but also contains an internal rechargeable battery capable of providing up to 36 hours of portable standby use walk testing for example The battery is charged automatically during mains operation The base station can also be powered by an external 12V DC supply the internal battery is charged during this mode of operation this facility is available to special order only A single on off switch this illuminates the yellow power indicator next to the switch The alarm sounder may be set to one of three modes Off Steady or Pulse by way of the audible alarm switch The nine bank LED display indicates an alarm condition by the individual zone numbers and remains illuminated until the reset switch is activated The incoming alar
5. m signal also triggers the sounder depending on the mode setting The reset switch is used to extinguish any illuminated zone LEDs as and when required It will also reset the low battery warning The sounder will operate again if a new alarm is received from a zone already illuminated on the LED display prior to reset The low Battery indicator illuminates on receipt of low battery warning transmitted by any of the detection heads See notes on Detector Head Batteries Alarm Outputs On the rear of the unit either a two pole terminal is fitted for providing a single common output for all alarms or a 15 pin socket is fitted for additionally supplying individual outputs for all eight alarms The individual outputs can be used for example to position CCTV cameras while the common alarm is suitable for activating existing alarm systems Intrusion Detection www cvigil co uk C VIGIL Ltd transport support cvigil co uk User Manual Page 7 AUTOGUARD Base Station Alarm Outputs A universally normally open contact available via the two pole terminal posts This output closes momentarily on receipt of a valid alarm signal from any of the 8 zones 15 pin D Connector 1 7 Alarms 1 7 9 Output common for all alarms Pin 8 amp 10 14 N C Pin 15 Alarm 8 These outputs are clean normally open giving momentary closure when a signal is received from any zone 125 System Code Transmission a
6. mp Settings On activation each detection head transmits two separate signal codes back to the base station A third low battery code will be transmitted when required 124 Storage Larry Case When not in use the system may be stored in a hard sided case for protection and ease of transportation and deployment Intrusion Detection www cvigil co uk C VIGIL Ltd transport support cvigil co uk AUTOGUARD User Manual Page 8 2 Qperation amp Deployment 2 General Autoguard is a completely self contained portable intruder detection system demanding minimal skill during deployment and subsequent operation Capable of monitoring up to eight separate zones from a single monitoring unit it provides invaluable protection for a vast range of security operations where mobility and versatility are the prime operational requirements The system is supplied in a robust protective case complete with the following items A battery mains operated base station monitoring unit complete with alarm outputs and integrated radio receiver Eight coded battery powered detection heads for portable deployment on the ship as required capable of transmitting radio signal back to the base station giving location number of alarmed area Operating instructions 22 Detector Deployment Remove the detector from its carry case Install the detector s in their final locations i Ona suitable bracket on the ship s
7. structure side rails ii Free standing on its tripod base iii Attached to a convenient point by the bungee cords Remove the protective cover from the detector www cvigil co uk Intrusian Detection C VIGIL Ltd transport support cvigil co uk AUTOGUARD User Manual Page 9 23 Receiver Base Station Deployment Power up the base station by connecting the mains lead into the back of the unit Switch the base station the mains LED will glow yellow indicating power is supplied to the unit The charging LED may also glow if the internal rechargeable batteries are at a certain voltage level This LED indicates the unit is also being charged this will not effect the application With all or several detector units deployed you may have several alarms showing this is normal because they would have been activated during installation Activating the reset button should clear these alarms if not check the detectors set up It is always required that a walk test be carried out on each detector location Once the base station is activated you can choose whether you want the activation audio able or silent In either mode the alarm LED will illuminate on alarm The base station can be operated for up to 36 hours on its own internal rechargeable batteries although it is normal to run the system from mains d Detector Battery Endurance Days Years No Alarms 5606 15 36 Days Years
8. y number of similarly coded heads repeater may be deployed in up to eight separate zones Each sensor is capable of continuous operation for up to about 10 years see Section 3 for battery endurance Alarm response is by way of passive infra red detection PIR The active alarmed area is a 30m beam detection zone from the sensor faceplate This gives excellent selective positioning control when deploying the units for example running along ship s open decks across hatch entrance way gangway access point The units have protective faceplate that also acts as an on off switch Note Environmental conditions may reduce effective operating distance Once the heads are activated they are ready for immediate deployment as and when required Optimum detection is achieved when mounted approximately 2m above the ground and positioned so that target movement will be across the zone rather than towards or away from the unit It is important to avoid situations where two or more heads can trigger simultaneously as this can corrupt the coded transmission to the base station Once deployed the detection zones be walk tested using the base station on battery power Note activated the head has reset time of approximately 5 seconds after movement has ceased Detector heads should be tested activated periodically otherwise after prolonged periods of inactivity the heads go to sleep and will requir
Download Pdf Manuals
Related Search
Related Contents
KOP302 Operating instructions Flash Socket Board Pro User Manual v1.00 Système d`anneau gastrique ajustable LAP-BAND AP jumbo tcs 60 User Manual - Goodson Imports (PDF) 取扱説明書 Mode d`emploi Manual Fornos a Gás PROMAQ com Infra Betriebsanleitung WTM-N28 Board User Manual Copyright © All rights reserved.