1.      an    Win     _        a                  Output Pi L Circuit Tuning capacitor Power supply board    subpanel    POWER SUPPLY    Power supply of the amplifier is effected by two 2kVA toroidal transformers  A soft  start is realized with the help of relays and resistors     The high anode voltage consists of 8 times 430V and 2A  Each of them has its own rectifier  and filter  In the high voltage circuit safety resistors are employed to protect the amplifier  against overload    The source for G2 is stabilized by a paralell stabilizator with BU508 transistors and delivers a  voltage of 360V at 100mA    The  120V for the control grid is stabilized by means of zener diodes     SAFETY DEVICES  Control and monitoring circuits ensure control and safety of the circuits of the device during    malfunction of the PA  They are placed on the Control board  which is located on the  subpanel     Putting the power amplifier into operation    Coaxial cable    The output of the transceiver is to be connected with the input of the amplifier via RG58 or  similar cable  For the connection between the power amplifier and the antenna RG213 or  similar coaxial cable suited for this high power is to be used  For INPUT and OUTPUT PL   259 sockets with Teflon isolation are used     Mains plug1 Mains plug2 Fuses OUTPUT       KEY OUT    Rear view of the amplifier  Control cable    With the control cable ensures switching from reception to transmission  The cable is  shielded  On the side of the pow
2.    Instruction Manual       OM3500 HF  SHORTWAVE POWER AMPLIFIER    OM POWER  s r o  93030 Bac 126  SLOVAKIA    Important safety instructions     e The amplifier contains high voltage circuits  Never turn the amplifier  on without the upper lid in place     e The OM3500 HF amplifier is not to be used in a wet or humid  environment nor to be exposed to rainfall     e The amplifier must be installed in such a way that free flow of hot air  from the tube is allowed  The amplifier must not be installed in  a constrained surrounding  i e  tight shelves etc      e During long operation the upper lid and the vent grid of the amplifier  can reach high temperatures that can cause burn injuries  Do not  touch these parts of the amplifier during operation     e The amplifier must be grounded during operation     e During operation the amplifier must be installed in such a way that the  rear power supplies are accessible     e The amplifier can be operated only if both supply cables are  connected  OM3500 HF reaches optimal parameters when it is  connected to 2 phases     e Do not turn the amplifier on without having connected the antenna   A hazardous HF voltage may built up on the antenna connector after  turning the amplifier on with no antenna connected     e Before opening the upper lid of the amplifier make sure that both  power supplies have been disconnected for at least 5 minutes  allowing the electrolytic capacitors to discharge fully  Never turn the  amplifier on without the u
3.  amplifier and must decrease the output    In SSB you will have a good output power if the green LED lights up a bit and the red  LED is only flashing at the highest peaks of your voice  The current of screen grid is  measured and shown in a Bar graph indicator  The amplifier has to be tuned in such a  way that the current is between   20 mA to  50 mA  At currents beyond these values  the operating point will be shifted and IM products will be generated  If a value of    TOMA is exceeded  the safety devices will switch the amplifier to STBY mode     Tuning instruction      Please note    Before starting tuning you have to check if the right antenna or a 50  Ohms load resistance is connected at the antenna output      Switching on the amplifier     e put the switch at the multimeter to HV position  e put the OPR STBY switch to STBY position  e press the    ON    button    The amplifier is prepared for operation with the following steps     the toroidal transformers are switched step by step    the blower of tube is switched on    the multimeter bargraph measures the high voltage  the normal value is 3 4 kV  the WAIT LED lights up    After switching on you have to check the functioning of the blower  Air must be blown out of  the ventilating apertures above the tube    If there is any failure you have to press the  OFF      button immediately    Heating the tube takes about 150 seconds  After this time the WAIT  LED goes out and the amplifier is ready for operation     Tuning t
4.  procedure the amplifier is tuned correctly and ready to give 3500W output power in  all operation modes  At optimal tuning and full output power a positive 50mA current goes  through the second grid  On 24 and 28 MHz bands optimal tuning can be achieved when one  or two LEDs are lights up to the left from the position    V     If less output is desired you can  simply decrease the load of the transceiver     Please note  Should the amplifier demonstrate any malfunctions  during tuning or should it not behave in accordance witch the  description  interrupt the tuning procedure immediately and check  the amplifier    Be sure to have not done any mistakes in choosing bands or  TUNE LOAD values    Be sure that SWR is not higher than 1 2 and input power is LOW   After cancelling human mistakes you will be able to work for long  time with this amplifier     Indication of fault conditions    OM3500 HF has the following indication LED on the front panel     GRID MIN   indication of first gird currency   GRID MAX   max  First grid currency exceeded   HV   measuring of anode voltage by bargraph   IP   measuring of anode currency by bargraph  FAULT   fault   OPR   amplifier in operation mode   STBY   amplifier in standby mode   WAIT   heating of tube after switching on the amplifier    Should a fault condition appear during the tuning or operation of the amplifier the  safety circuits of OM3500 HF will react  The amplifier will be turned to STBY mode   After approx  1 sec the control c
5. Mistuning of power amplifier  Soft start for protecting your fuses     switch    on blocking     at opened amplifier      Power output     bargraph 50 LED    reflected power     bargraph 20 LED  current at screen   Ig2     bar graph 10 LED    anode voltage  anode current  tuning     bargraph 30 LED    current at control grid   Ig      2 LED    WAIT     preheating of tube  180 sec    STBY   standby  OPR   operating condition  FAULT     failure   switching off for abt  4 sec    485 x 200 x 455mm  width x height x depth   43 kg    General Description of OM3500 HF POWER AMPLIFIER    HF PART   In this amplifier a tetrode GU 78b is used in a grounded cathode circuit  input into control  grid   This amplifier achieves excellent linearity by the voltage stabilization of the control grid  bias and the screen voltage  The power input is given to the control grid  using a broadband  power transformer with an input impedance of 50 Ohms  This adaptable input circuitry    ensures a good input SWR lower than 1 5 1 on all short wave bands   The output of the amplifier is a Pi L circuit  The ceramic capacitor for TUNE and LOAD are    divided  This enables the amplifier to be tuned exactly and makes it possible to easily return  to the previously set positions after band change     Top view on the opened OM3500 HF    Tetrode GU78B Outputindicator Blower switch on board         S  U    ia    at    ne    f    a a           I  h                 ih  ie caca  Ahi  U i   AU A  A VANE all  E     22 1
6. as to be grounded properly  Connect the screw on the rear panel of the  amplifier to your local grounding system with a copper cable  use a cross section of 4 mm   at least    Connect your transceiver to the same grounding system of your shack carefully    If you use a power amplifier with higher output you have to be aware that your grounding  system works properly  All parts have to be grounded to the same system  Use short  cables and make sure that there are good contacts  Otherwise you run the risk of damaging  your equipment  having problems with TVI BCI or your signal may be distorted     Cooling    The centrifugal blowers provide the necessary cooling of the amplifier  even during long  contests  The main blower is activated by switching the PA on and it is turned off when after   cooling is finished  approx  1 5 min after switching off the PA depending on the temperature  of the tube   The supplemental fan is turned on depending on the temperature of the air  exiting from the amplifier  It is switched on at 70  C and switched off at 60  C     Operation    Operating elements  see photo of front panel   BAND   band selector switch  in MHz     TUNE   Anode capacitor for tuning  tuning of higher frequencies to  0    lower frequencies to    100        LOAD   Output capacitor tunes antenna load resistance to amplifier   Capacity is low at    0    and high at  100  on the scale     OFF   You switch off the amplifier by pressing this button     ON   You switch on the amplifi
7. er amplifier a CINCH socket is used  On the side of your  transceiver you have to use a socket suitable for this transceiver  During transmitting the  middle pin is connected to the ground     The relays of the OM3500 HF have to be switched earlier than HF is applied  cold  switching     Modern transceivers have a time delay between PTT switching and power output    If you are using and older transceiver or transmitters without time delay we recommend to  connect the PA in such a way that the transmit  receive switch is connected with the KEY IN  socket of the amplifier  The KEY OUT socket is to be connected with the PTT socket at the  transceiver     The amplifier is equipped with two safety devices  which ensure that the Output relay is not  switched under power mistakenly  hot switching      MAIN SUPPLY     The amplifier is connected to the mains with 2 cables with an EURO end  Each cable is  to be switched to another phase of your main supply system  Both of them have to be  able to deliver a power of 2 5 kVA     If you use only one phase  you have to connect both cables to this one phase   Your  main supply has to be able to deliver 5 kVA on this one phase  In this case the power  amplifier can   t deliver full output     ATTENTION     In each case the power amplifier has to be  connected to your main supply system with the  2 cables  Normally the amplifier is used at 2  phases  If there is only one phase connect the  2 cables to this one     Grounding    The amplifier h
8. er by pressing this button   Heating of tube is on and after 3min of delay the amplifier will be  ready for operation     OPR STBY      OPERATE    you will be ready for operation   At STBY  if WAIT LED is on or the amplifier is off your transceiver is in  bypass mode directly connected to antenna  Maximum 200Watts    400Watts version is possible  FT9000   Please tell us at order      RF OUTPUT   Bar graph     shows output power      REFLECTED POWER   Bar graph     shows reflected power of the antenna  350W  maximum or amplifier switches to STANDBY mode    Ig2 Bar graph     measerus the currency of the second grid in the  range from  20mA to  80mA  HV IP TUNE Bar graph     measure the anode voltage  anode currency or    tuning of the amplifier    TUNING    The OM3500 HF amplifier is operated in class AB  Thus it   s possible to obtain a  maximum output power at an excellent linearity  For this purpose the amplifier has to  be tuned carefully    The operation of a mistuned PA will cause malfunctions  the increase of grid current  the  GRID MAX LED will light up  and problems with TVI BCI     The grid current is shown with 2 LED diodes  It   s normal if the green LED is flashing or may  be shining a little bit during peak operation  If you overload the amplifier the output power  increases the grid current at very small rates and the red GRID MAX LED is shining and the  safety devices the PA to STBY  If the red GRID MAX LED lights up with full intensity  you  have overloaded the
9. he amplifier to an output of 3500W    1  Switch BAND  TUNE and LOAD to the position according to the table   PB 4      A fk     pO a    Po BM 9      Po        409_       pt a   4   32    0  22  10  32   0  64  58  72    1 8  3 5  7  10  14  18  21  24  28       The tuning table available to you is made by using a dummy load  Each amplifier will have  other values depending on used frequency and antenna  Make your own list for your own  antennas  Use tuning position  see later      2  Reduce the power output of your transceiver to the 0    3  Switch OPR STBY to    OPR    position  OPR LED lights up    4  Choose TUNE position of multimeter    5  Switch the PA to CW and increase output by 10W  OUTPUT PA abt  500W     Please note     If the input power is higher than 15 W and the power amplifier is not correctly tuned  the  safety devices will switch to STBY    After switching the amplifier to PTT  the amplifier will automatically reset and switch back to  OPR mode after approximately 2 seconds     6  Set TUNE in such a way  that the TUNE LED lights up maximum left    7  SetLOAD in such a way  that the TUNE LED on the TUNE scale lights up under  the    V    sign  If it is possible to obtain the LOAD in 2 positions  set the position  that is father to the right    8  Repeat tuning several times according to 6 and 7    9  Increase the input power until an output power of approximately 3500 W is reached    10  Repeat steps 6 and 7   11  Set TUNE to maximum output power    After this
10. ircuits will switch the amplifier back to OPR  If the  fault will repeat 3 times after each other the control circuits will turn the amplifier to  STBY  Brining the amplifier to OPR is enabled by using the OPR STBY switch   After the reaction of safety circuits the FAULT LED will be lit up for approx  5 sec  depending on the nature of the fault     Flashing LED signalizes     IP   anode currency exceeded  HV   low anode voltage  FAULT   reflected output exceeded  GRID MAX   first grid currency exceeded    second grid currency exceeded  GRID MAX   HV   maximum load power exceeded  GRID MAX   IP   zero output power during tuning  HV   IP   tuning fault  incorrect tuning of the Pi L output circuit    In case your OM3500 HF amplifier is not working  please contact the  manufacturer     IMPORTANT WARNING    e The OM3500HF amplifier is not to be used in a wet or humid environment nor to be  exposed to rainfall    e The amplifier must be installed in such a way that free flow of hot air from the tube is  allowed  The amplifier must not be installed in a constrained surrounding  i e  tight  shelves etc     e During long operation the upper lid and the vent grid of the amplifier can reach high  temperatures that can cause burn injuries  Do not touch these parts of the amplifier  during operation    The amplifier must be grounded during operation   During operation the amplifier must be installed in such a way that the rear power  supplies are accessible    e The amplifier can be opera
11. pper lid in place     e Make sure that all screws holding the case together are properly in  place and tied before carrying the amplifier by the handles     e The amplifier is an A category product  In a household it can influence  other electric appliances  In such cases the user is to take proper  actions to mitigate this disturbance     General description    of the OM 3500 HF Amplifier    The linear amplifier OM 3500 HF is designed for all short wave amateur bands from  1 8 till 29 MHz  including WARC     bands   and all modes   It is equipped with    a ceramic tetrode GU78b     Specification of OM 3500 HF     Frequency coverage   Power output    Drive Power    Input impedance    Output amplification   Output impedance   Maximum output SWR   SWR protection    or higher   Intermodulation distortion    Suppression of harmonics   Tube    Cooler     Power supply    Transformers     Protection circuits       Bar graph indications     LED indicators      Parameters   Weight     amateur bands 1 8     29 7 MHz including WARC  3500 W in SSB and CW 3000 W in RTTY  AM and FM  60 to 80 W for full Output Power  50 Ohm VSWR  lt  1 5  1  17 dB  50 Ohm unbalanced  2 1  automatic switching to STBY   when reflected power is 350W    32 dB below nominal output   lt   50 dBc  GU78b Ceramic tetrode  Centrifugal blower   axial blower  2 x 230 V   50 Hz one or two phases  2 pcs of toroidal transformer 2 5 kVA  SWR too high  Anode current too high  screen current too high  grid current too high  
12. ted only if both supply cables are connected  OM3500HF  reaches optimal parameters when it is connected to 2 phases    e Do not turn the amplifier on without having connected the antenna  A hazardous HF  voltage may built up on the antenna connector after turning the amplifier on with no  antenna connected    e Before opening the upper lid of the amplifier make sure that both power supplies have  been disconnected for at least 5 minutes allowing the electrolytic capacitors to discharge  fully  Never turn the amplifier on without the upper lid in place    e Make sure that all screws holding the case together are properly in place and tied before  carrying the amplifier by the handles     
    