Home
556c04 tabloid.p65
Contents
1. Specifications Temperature range Heating 43 86 F 6 30 C Cooling 61 104 F 16 40 C Dead zone options 2 5 7 10 F 1 2 3 4 C selectable by installer Programming options All models can be set for 24hr 5 2 or 7 day operation by installer Programmed events per day Non programmable 2 4 or 6 selectable by installer Vacation programming option Up to 99 days heat amp cool set points can be set independently Factory pre set programs Yes refer to user manual details Control ouput PI algorithm with Chrono proportional output and adjustable cycle rate Power supply 24 volt models 20 30 Vac 60 Hz Battery model 2 x AA alkaline batteries Memory retention Rechargeable on board battery for real time 48 hours when fully charged non volatile memory device for all other settings Fan mode options Auto On or Smart Fan all programmable Programmable Occupancy Relay Yes most models User mode selection Heat cool models Heat pump models Heat Cool Auto Off and holiday and thermostat mode Heat Cool Auto Off plus emergency heat holiday and thermostat mode Output relay voltage rating 10 24 Vac Output relay current rating 10mA to 2A resistive Installer DIP switch settings Yes refer to Installer Setting Guide Installer advanced programming settings Yes refer to Installer Setting Guide Installer service mode option Yes
2. 211 1RJ 087N6959NA 3 Heat 2 Cool for heat pump systems HP8321 1RJ 087N6963NA Remote room sensor 087N728500 Duct mounting sensor 087N681200 Outdoor sensor 087N681300 Optional wall plate for 8000 Series thermostats 087N8000WP Sensor Averaging Single sensor Two sensors arranged for averaging ajeje Alee LTT 1 THERMOSTATS Ta ALL 8000 8000 15 ALL 6000 13 5 Three sensors arranged for averaging Four sensors arranged for averaging Danfoss Randall can acceptno responsibility for possible errors in catalogues brochures and other printed material and reserves the rightto alter its products withoutnotice This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed Pan fess Danfoss Comfort Controls Danfoss Inc 7941 Corporate Drive 7880 Tranmere Drive Baltimore MD 21236 USA Mississauga ON L5S 1L9 Canada Tel 443 512 0266 Fax 443 512 0270 Tel 905 676 6000 Fax 905 676 0279 www danfossheating com Literature Part No 556 Iss04 11 03
3. Data Sheet lri Features 8000 Series Programmable Thermostats for Heat Cool amp Heat Pump Applications Desf ap Fa ef 4 i a D The 8000 Series of programmable room thermostats provide control of multi stage heating and cooling systems including heat pump systems In addition to the normal thermostat functions 8000 series models incorporate a wide range of advanced features which are selected and programmed by the installer at the time of installation All models offer 7 day 5 2 day and 24 hour programming options and can also be set up as non programmable thermostats if the application requires it All models offer 2 4 or 6 time and temperature events each day with dual set point adjustment allowing the heat and cool set points to be set completely independently of each other In addition to temperature programming fan operation and occupancy relay on models so equipped can also be programmed allowing maximum flexibility when using dampers or UV lights etc All models incorporate two separate optimum star controllers one for heat and one for cool which bring on the system ahead of the programmed time The recovery time period varies as a function of load but has a maximum limit imposed on it to prevent excessive energy consumption The majority of the advanced features are selected and set in the advanced programming mode and can be protected by an electronic keyboard lock that can be set to partial
4. cle 3 Fanrun on timer after each heating cycle OFF 30 60 or 90 Fan runs on for additional 30 60 or 90 seconds after seconds each heating cycle When enabled this feature sets 3 functions 1 Occupancy relay can be set to open or close at each event time 2 The fan can be set for AUTO or ON at each event time 4 Enable or Disable occupancy relay and Smart DIS able En able 3 Optimum Start Control will be effective at each Fan Programming event time When this feature is disabled the Occupancy Relay and smart fan energizes at first programed event time and de energizes at the last programed event time and OSC will only operate at the first event time of the day ALL allows AUTO ON or SMART fan to be selected 5 Fan Lock ALL LOC LOC disables the fan button and locks the thermostat in SMART fan mode NOR PROG key disabled and temperature override z r limited to 3 F up or down from setpoint This feature 6 Use of keyboard disable DIP switch 5 NOR FUL may be used in conjunction with options 1 amp 5 FUL full keyboard lockout 7 Mininmaunideadband 5 F 2 F 7 F or 10 F Minimum temperature difference between heating and cooling setpoints 8 Max Heating Temp 86 F 85 F to 43 F Used in conjunction with Option A 9 Min Cooling Temp 61 F 62 F to 104 F Used in conjunction with Option b A Min Heating Temp 43 F 44 F to 86 F Used in conjunction with Option 8 b Max Cooling Temp 104 F 103 F to61 F Used in conjunction with Optio
5. ly or totally disable the keyboard function during normal operation This lock is in addition to the mechanical locking device for the cover supplied The 8000 series is available in conventional heat cool versions including a universal model with reversing valve connections that can be used in simple 1 heat 1 cool heat pump systems and in full featured heat pump versions All models can be used with either the built in sensor incorporated in the product or with remote sensors Up to four remote sensors can be used to provide temperature averaging please refer to wiring information for connection details Summary of Features E All models provide 7 day 5 2 day and 24 hour programming options E All models can be set up as non programmable thermostats E All models can be set up for 2 4 or 6 event each day E Heat cool models available in 1 heat 1 cool amp 2 heat 2 cool versions E Heat pump versions available in 2 heat 1 cool and 3 heat 2 cool versions all with auxiliary emergency heat control switch E All models provide programmable fan settings including smart fan HM Most models offer programmable occupancy relays for controlling dampers UV lights etc E All models offer optimum start control for heating and cooling recovery period E All models offer a service mode which allows the installer to manually sequence the heat cool and fan stages during system start up Refer to Installer Setting Guide
6. n 9 Sets the maximum amount of start up time for c Optimum start control for heating 0 off 1 8 heating 1 15 mins 2 30 mins up to 8 120mins Refer to table on page 7 d Optimum start control for cooling 0 off 1 8 See above E Calibration OF 3 F to 3 F Raises or lowers display temp in 1 F steps F Compressor minimum off timer 4 mins 3 mins or 2 mins Sets the compressor min Off time for each cycle H Compressor minimum on timer 2 mins 0 4 mins Sets the compressor min On time for each cycle 22 F to 60 F or Below this temp the thermostat switches off the heat L__ Low balance point low temp cut off 16 F Off pump and runs with auxiliary heat alone Only available when outdoor sensor is installed Above this temp the thermostat switches off the N High balance point 50 F 32 F to 70 F or Off auxiliary heat and runs with the heat pump alone Only available when outdoor sensor is installed Remote ro m sensor disable En able DIS able Disables or enables the remote room sensor Only available when remote sensor is installed Ordering Details Number of Stages amp Application Model Code Number 1 Heat 1 Cool for heat cool systems no occupancy relay HC8111 1 087N6807NA 1 Heat 1 Cool for heat cool or heat pump systems HC8111 1RJ 087N7224NA 2 Heat 2 Cool for heat cool systems HC8221 1J 087N6939NA 2 Heat 2 Cool for heat cool systems battery operated HC8220 1J 087N6940NA 2 Heat 1 Cool for heat pump systems HP8
7. refer to Installer Setting Guide Minimum On Off Time Control Yes adjustable all models Reversing Valve Connections All HP versions amp HC8111 1RJ model Heat pump balance point control HP Models Yes programmable high and low balance points outdoor sensor required Lockable keypad Full Partial Electronic keypad lock plus mechanical locking catch on cover flap Limitation of high amp low set points Both heat and cool ranges can be limited or locked Optimum Start Control Yes separate settings for Heating amp Cooling modes Limitations of temperature override Can be limited to 3 F 2 C or disabled Temperature Override Can be limited to next event 1 2 3 or 4 hours or disabled Max ambient temperature 113 F 45 C Software Version Valid for software version 3 00 Dimensions inches 5 1 8 x 4 7 16 x 1 1 16 Maximum remote cable sensor length 160 feet 50 meters Advanced Programming Options Option Description Default Setting Optional Setting Comments 1 _ Temperature override timer NE next timed event will reset 1 2 3 or 4Hr or 1 2 3 or 4 hours override or override disabled the override DS 30 60 or 90 Fan runs on for additional 30 60 or 90 seconds after 2 Fanrun on timer after each cooling cycle OFF seconds each cooling cy