        Industrial Solar Power PoE Switch BSP
         Contents
1. Industrial Solar Power PoE Switch    BSP 300    Quick Installation Guide    Safety Precautions    Please read before using    1  All electrical work must be done in accordance with local  and or international  electrical codes     2  Before installing or using this device  read all instructions and cautionary marking  located in  or on  this guide  the controller  the batteries  PV  Photovoltaic  array  and any other device used     3  To reduce the risk of short circuits  use insulated tools when installing or working  with the inverter  the controller  the batteries  or any DC source  e g   PV      4  Remove all jewelry  This will greatly reduce the chance of accidental exposure to  live circuits     6  The controller contains more than one live circuit  batteries and PV array   Power  may be present at more than one source     7  This product contains no user serviceable parts  Do not attempt to repair this  unit unless fully qualified     1  Package Contents         2  Overview                     3  Hardware Installation    Further Information            Table of Contents       1  Package Contents    e i x BSP 300   e 1 x Quick Installation Guide    1 x RS232 Console Cable   e i x CD   e 2 x Rack Ear    e i x Screw Kit       2  Overview    System LED  FAULT LED    10 100 1000Base T  PoE port x 2    Link ACT LED    PoE in Use LED    10 100Base TX Link ACT LED    1000Base T Link ACT LED    4 Pin Terminal    PV In    Battery In   Out    10 100   1000Base T port    RJ 45 typ
2. e  RS 232 Console                               Block  LED Definition  LED Status Description  Slow Blink   System On   System        Fast Blink The battery is Charging   Slow Blink   The PV disconnects   Fault Fast Blink The battery voltage is less than the value for  low voltage disconnection   On Bad Battery   Over current   Short circuit   Link ACT On The 10 100 1000Base T PoE port is link up      For Port 1 2  Blink    The BSP 300 is actively sending or receiving  data over that port                                  On A PoE device is detected   PoE in Use    Off No PoE device attached   The port is running in 1000Mbps speed and  On A  1000 successfully established   Blink The BSP 300 is actively sending or receiving  data over that port   Link ACT On The port is running in 10 100Mbps speed and  successfully established   glia The BSP 300 is actively sending or receivin  For Port 3  Blink 4 g 3    data over that port           SE       3  Hardware Installation    Solar Power System    Long range Wireless    Backhaul Bridge Wireless CPE AP Solar PV        Battery    BSP 300    Ethernet Extender  Laptop    DC Powered Device Local Console                      _ 1000Base T UTP with PoE b   EI       Serial Line  RS XXX   1000Base T UTP    _          Power Line  DC     Please follow the following steps  sequence  to install the system     Step 1  Install BSP 300  Fix BSP 300 to desired location with wall mount fixture          Please install the BSP 300 in a proper enclosure o
3. external device should also be grounded properly           After the 5 steps above  the BSP 300 is ready for service        Further Information    For more information about this Solar Power PoE Switch  please refer to the user  manual from the supplied CD ROM     
4. r shelter       The BSP 300 must be grounded                 Step 2  Install battery     1      2      3           Bat  In Out       Battery    Connect the negative electrode of the battery to the terminal for the negative  electrode of the battery on the BSP 300     Connect the positive electrode of the battery to the terminal for the positive  electrode of the battery on the BSP 300     After the battery is well connected to the BSP 300  the System LED will ON  with slow blinking for system ready and the Fault LED will slow blinking for PV  not connected        e Be noted for the thickness of electric wire and please refer to  the section   Recommended Use of the Connection Wires of  the user manual     e The BSP 300 accepts DC 24V battery system  please pay atten   tion to the battery characteristics and also refer to the section    Recommended Settings for Different Batteries of the user  manual     e Check the total power consumption of your connected network  device before installation  Improper battery capacity could  shorten the battery life or make your network device lack of  power supply           Step 3  Install PV panel    Solar PV        1  Connect the negative electrode of the PV panel to the terminal for the  negative electrode of the PV panel on the BSP 300      2  Connect the positive electrode to the terminal for the positive electrode of the  PV panel on the BSP 300      3  After the PV is well connected to the BSP 300 and providing 24V or above  voltage  
5. the System LED will fast blinking for battery charge if the battery is  not full  And turn off the fault LED        e Be noted for the thickness of electric wire and please refer to  the section   Recommended Use of the Connection Wires of  the user manual     e The BSP 300 supports maximum 45V DC input  please refer to  the Specification of the user manual before installation     e Check the total power consumption of your device and the  sunshine duration of your area from weather bureau for a  proper PV  Improper PV could shorten the battery life or provide  insufficient power to BSP 300                 Step 4  Connect 8023af   802 3at PoE Device        1  Connect the PoE devices to Port 1   Port 2 of the BSP 300      2  Check the PoE In Use LED  if the network devices such as PoE Camera  PoE  Wireless AP is powered  the PoE In Use LED will turns ON and Link Act LED  will turns on or blinking for a success connection or data receiving          Please use Cat  5 5e or above cable and the maximum distance  should within 100 meters       If the Network devices are installed outdoor  please consider to  install a lightening arrestor to protect the network device and  BSP 300                 Step 5  Connect other device       Ethernet Extender     1  Connect any other network device to Port 3 of BSP 300      2  If there is device require DC power  connect the pin 3   pin 4 of the terminal  block from BSP 300 directly       The maximum DC out from BSP 300 is 24VDC  2A       The 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
User Manual - Culvert Design  Samsung HW-F850 Sound Bar Air Track User Manual  Magnetek Material Handling IMPULSE •LINK 4.1 Basic  超軽量金属探索機 取扱説明書      User Manual - AMTEC Logo  user manual - Pdfstream.manualsonline.com  PROFIBUS DP/PA - Endress+Hauser Portal  Manual - Crestron    Copyright © All rights reserved. 