MAN-182 Vibrating Wire Handheld Readout
Contents
1. Gauge Calibration Constant for Period Units Base reading f 1000 units Current reading in f 1000 units Please see Appendix 1 for more information on Vibrating Wire data User Manual 7 Section 4 Troubleshooting Guide If a failure of any vibrating wire transducer or its electrical cable is suspected the following steps can be followed The transducers themselves are sealed and cannot be opened for inspection The Troubleshooting Flowchart should also be followed if any instrument failures are suspected The steps below and the Troubleshooting Flowchart are applicable generally to any vibrating wire instrument Step 1 Before any of the following steps are followed the readout unit should be used to verify the stability of the reading The period reading from the transducer should not vary by more than 3 units An unstable wildly fluctuating reading from a transducer is an indication of possible problems with instruments or their related electrical cables IMPORTANT If a handheld readout is giving faulty readings from all transducers a faulty readout unit must be suspected Another readout unit should be used to check the readings from the transducers and Soil Instruments Ltd should be consulted about the faulty readout unit Before proceeding to Steps 2 and 3 if possible the continuity should be checked between conductors and earthing screen of the electrical cable If continuity exists a damaged cab
2. Sweep Range button should be pressed and immediately released The LCD display will briefly indicate the Sweep Range number 1 to 4 and the range frequencies 450 to 1250Hz 800 2000Hz 1400 to 3500Hz and 2400 to 6000Hz and then start sweeping the sensor wire with the current Sweep Range approximately every 4 seconds User Manual 6 3 05 LCD Back Light For low light sensor reading the LCD display maybe backlit to assist display viewing The backlight is switched on and off by pressing and releasing the Back Light button It should be noted that use of the backlight will significantly decrease battery life 3 06 Auto Timeout A power saving Timeout feature is built into the software which will shut down the Handheld Readout after 30 minutes of operation 3 07 Maintenance Little maintenance is required apart from wiping over the Readout casing with a damp cloth to remove dust and dirt and the occasional replacement or recharging of the dry cell batteries Spare batteries should be considered so that continuity of service maybe assured 3 08 Data Interpretation Conversion of Period and Linear Units to Engineering Units is carried out using the formulae detailed below Period Units Where P Engineering Units Gauge Calibration Constant for Period units Base reading in Period units T Current reading in Period units Frequency2 Units P K 0 0001 Where P Engineering Units K
3. ach instrument is supplied with a Calibration Constant value to convert the raw data into Engineering Units The value of the calibration constant will vary depending upon the engineering units into which the data is to be converted and the readout units For example the data from piezometers may convert into mH50 Bar Psi etc and therefore the Calibration Constant for each will be different Some instruments have Generic Calibration Constants and others are individually calibrated to generate the Constant The constant is generated by using the following calculation Constant 107 107 R1 R2 R1 Reading at zero range R2 Reading at full range scil INSTRUMENTS Bell Lane Uckfield East Sussex t 44 0 1825 765044 e info itmsoil com TN22 1QL United Kingdom f 44 0 1825 744398 w www itmsoil com Soil Instruments Ltd Registered in England Number 07960087 Registered Office 5th Floor 24 Old Bond Street London W1S 4AW User Manual 10
4. anical damage dropping by housing in a soft TPE rubber case protector Power is provided via 4 AA replaceable supplied with unit or rechargeable dry cell batteries providing up to 30 hours of non backlit reading time A power saving feature shuts down the Readout after 30 minutes from turn on Equipment Supplied 1 No Vibrating Wire Handheld Readout housed in case protector 4 No AA dry cell batteries Non rechargeable 1 No Readout to bare wire crocodile clip flylead 1 No User manual Vibrating Wire Handheld Readout with crocodile clip flylead User Manual Section 3 Operating Instructions Remove the Handheld Readout packet of batteries and flylead s from all shipping packaging 3 01 Fitting the Battery Before operation the batteries will need to be fitted which requires turning the Readout over so that it is facedown At the back of the Readout head a black access cover can be identified with a clip closure at its upper end The cover is removed by inserting a fingernail at the top of the clip and depressing it The cover will unclip loose then it may be removed and put to one side The battery compartment is now revealed The four AA batteries may now be inserted between the terminals ensuring correct orientation according to the clear markings beneath each battery location Once located the battery compartment cover may now be replaced Make sure the light grey seal encircling the battery compar
5. le is confirmed Step 2 The resistance across the two conductors of the electrical cable should be checked This can be done using a multimeter device across the two exposed conductors if the cable has not been connected to a terminal cabinet or can be done just as easily across the two conductors if the instrument has been connected to such a terminal or dataloggers The resistance across the two conductors should be approximately of the order of 800 to 1800 The majority of these resistances arises from the transducer and the remainder from the electrical cable connected to the transducer Step 3 If the resistance across the two conductors is much higher or lower than the values quoted in Step 2 or is infinite a damaged cable must be suspected Step 4 If the resistance is within the values quoted in Step 1 i e 800 to 1800 AND no continuity exists between conductor and earth screen and on checking the reading from the transducer it proves to be still unstable or wildly fluctuating it must be assumed that the integrity of the circuit is good A faulty transducer must be suspected and Soil Instruments Ltd should be consulted NOTE If the location on site of cable damage is found the cable can be spliced in accordance with recommended procedure with suitably qualified personnel User Manual 8 TROUBLE SHOOTING FLOWCHART User Manual R is very hig R is between 8Q and 1802 A severed cable is suspected causi
6. ng very high or infinate resistance Appendix Vibrating Wire Data Vibrating Wire Units Frequency Units f The tension of a wire can be measured by registering the frequency note at which it naturally vibrates If the wire is swept electronically the frequency at which it vibrates can be measured The most common units used to express frequency are Hertz Hz or Kilo Hertz KHz The disadvantage of these units is that there is no linear conversion from Hertz to change in wire tension Frequency2 1000 Units L In order to overcome the problem of a linear conversion described above the frequency value can be squared thereby rendering it linear but quite large To reduce its size it is often divided by 1000 or multiplied by 10 The expression f2 1000 or f2 x 10 is the most commonly adopted as a linear output Period Units P Electronic devices and digital technology often utilise the counter function available in some common circuits Period Units represent the time taken for the wire to vibrate over one full oscillation expressed in seconds Due to the very small size of the number generated most equipment manufacturers display the unit multiplied by 10000000 or 107 The relationship between Period Units and frequency units is expressed as 1 Frequency Period units are therefore convenient to measure but do not have a linear relationship to change in wire tension Calibration Constants E
7. scil INSTRUMENTS Vibrating Wire Handheld Readout User Manual Mani82 2 0 2 07 08 2014 Rob King Phillip Day Phillip Day Mason Manual No Revision Date Originator Checked Authorised for Issue User Manual Contents Section 1 Foreword eseeseeireeeeeneeeu a a annu au unma nnn 3 Section 2 Introduction e eee aaa a a aa a aa ne unma nuam u umana aua auras eua usua nun 4 Equipment Supplied eiie ee DR EA MAP C UDIN V DO eine dee CA 4 Section 3 Operating Instructions 5 3 01 Fitting the Battery serene eren rrr aei sale 5 3 02 Sensor Cconnectiorma OR na 5 3 03 Selecting displayed UNits oo nnn nnn 6 3 04 RR IRR RR MIN RE 6 3 05 ECD Back LBight heo Ee DDR e 7 3 06 Autos TIMEOUT socer eee ox mee xe xen etum mee oec cele a d haus ce en weed dae nati s me e rt 7 3 07 Maintenance oe ee Re I y anes EIU RR RA RE Et xe ERR UNE ERA EA pU Nae EI ERR 7 3 08 Data Interpretatlon s 7 Section 4 Troubleshooting Guide 8 TROUBLE SHOOTING FLOWCHART e seeseenn enne nnn nahm u nana haue u neue u usua sunu 9 Appendix A Vibrating Wire 10 User Manual Section 1 Foreword Soil Instruments Vibra
8. ting Wire Handheld Readout as with all our equipment has been designed to operate consistently in a construction site environment and is therefore relatively robust However it is essential that the equipment covered by this manual is handled operated and maintained by competent and suitably qualified personnel They must READ AND UNDERSTAND the procedures outlined in this manual before attempting operation of the equipment on site Soil Instruments will not accept for repair under guarantee instruments that have been neglected or mishandled in any way User Manual 3 Section 2 Introduction The Soil Instruments Vibrating Wire Handheld Readout has been developed as a low cost vibrating wire and thermistor reader to complement the company s existing Portable Vibrating Wire Logger The design provides a lightweight 680gms compact 250x125x25mm and single handed operation field means of exciting vibrating wire sensors and their thermistors 3KQ at 259C and displaying their readings in a choice of three frequency related formats Frequency F2 1000 or Period and transducer temperature in degrees Centigrade via a switchable back lit LCD display for manual recording Wire excitation is swept with four user selectable sweep ranges The body of the readout is of tough ABS plastic faced with a four button membrane keypad and readout display With an ingress protection rating of IP65 the casing is additionally protected from mech
9. tment has not been displaced from its groove If so push it back into place so that it is sitting evenly within the groove Locate the lower end lug on the compartment cover into the compartment lower end slot and then push down the cover at its upper end until the clip clicks clearly into place 3 02 Sensor connection Turn the readout back over and remove the dust cap from the connector socket located at the top end of the readout Store this cap safely Take the required flylead and carefully aligning its connector with the socket push the two together until they click The other end of the lead may now be connected to their sensor or switchbox If using the crocodile clips ensure that red is connected to red and the black crocodile clip to the black or sometimes blue sensor wire The polarity of the thermistor wires if fitted to the sensor usually green and white is not important but for convention white connect to white and green connect to green Make sure that the wires and crocodile clips are lying so that they do not touch each other If the vibrating wire circuit should short the VW Readout will shut down to protect the circuitry If connecting to a switchbox via the switchbox flylead insert the connector into the switchbox socket after careful alignment and select the required sensor via the rotary channel switches The Handheld Readout is now switched on by depressing and holding the On Off but
10. ton for about 1 second until Soil Instruments appears on the LCD screen release the on off button and Handheld VW Readout scrolls across the lower row There will then be a pause of 5 seconds or so whilst the Readout self tests and checks after which the upper row will display the vibrating wire reading in frequency and the lower row the sensor temperature in C User Manual 5 If no thermistor is connected the message NO THERMISTOR will be displayed which is just a prompt and maybe ignored if not applicable Battery compartment amp flylead socket 3 03 Selecting displayed Units When switched on the Readout always defaults to whichever reading units were selected when the readout was last used If a different reading unit is required the Units button should be pressed and immediately released The unit type may take up to 2 seconds to change Pressing the Units button again will scroll to the next unit displayed in the order 3 04 Selecting Sweep Range For accurate and stable sensor readings we need ensure that the sensor is correctly connected to the Readout and that the selected sweep range encompasses the current sensor wire frequency If not readings will not be stable If the current sensor frequency is not approximately known the most suitable Sweep Range may be found by experimentation trying each Sweep Range until the a stable displayed reading is shown Similar to the Units button the
Download Pdf Manuals
Related Search
Related Contents
平成24、25年度「」【PDF:5.54MB】 Tacens Initio II 450W Epson Expression XP-820 Lettre ouverte au Comité de pilotage P.a. Monsieur le Conseiller d Ergonomie des Interfaces Homme-Machine Samsung 23" Hub Monitor CA750 LC23A750XS/EN Brugervejledning KETTWIESEL Anleitung, Version ab08/2014 Copyright © All rights reserved.