1. To install paper roll Insert rod ends into sockets under head end of upholstery To install paper tear strap Attach strap to snaps on each side of table MA801 8i 1 Midmark Corporation 2009 Stirrups Caution Be sure the stirrups are locked in place before using The stirrups will not support the patient s entire weight To position the stirrups A Pull the stirrup out then unfold B Lift the stirrup slightly then move it left or right as desired C Release stirrup to lock in position MA7995i 1 3 Midmark Corporation 2009 Footrest amp Treatment Pan Caution Do not use footrest to support patient s entire weight To access the treatment pan Lift footrest pad slightly then slide pad back into table To extend footrest MA7994i Pull footrest out to desired position Drawer Heater The drawer heater warms the contents of the drawer to approximately 98 F 37 C To turn the drawer heater ON OFF Press and release the drawer heater switch Switch will illuminate when heater is ON PA MA7990i Drawer Heater Switch 1 4 Midmark Corporation 2009 L lt Pelvic Tilt To elevate seat section Lift seat until pelvic support drops into place Pelvic Support To return seat section to flat position A Lift seat section slightly B Pivot pelvic support handle upward C Lower seat section MA7991i 1 5 Midmar
2. Press amp release the Quick Exam button Note In the event of a malfunction press the Stop button to terminate movement Base Up Quick Exam p Equipment Alert If the table s weight limit is exceeded you will hear a beep and the function will be disabled If the problem occurs with a normal Stop aa load contact your service technician 1 0 Midmark Corporation 2009 Exam Assistant Drawer System To use the drawer front as a shelf Pull drawer front down to release the magnetic latch Equipment Alert The maximum weight the shelf will support is 10 Ibs 4 5 kg If drawer front folds past horizontal Pull drawer front upward until it snaps back into the horizontal position Equipment Alert o If drawer front folds past horizontal do not operate table MA7996i 1 1 Midmark Corporation 2009 Paper Roll amp Tear Strap Upholstery sets are available in two widths 28 standard amp 32 optional Paper rolls of common size may be stored under the back section as follows Uph Width Paper Roll Size Max Qty 28 in 21 in long x 3 0 in diameter 53 3 cm x 7 6 cm 4 28 in 21 in long x 3 5 in diameter 53 3 cm x 8 9 cm 2 32 in 24 in long x 3 0 in diameter 70 cm x 7 6 cm 2 32 in 24 in long x 3 5 in diameter 70 cm x 8 9 cm 1
3. i Clearance MA8022i Midmark Corporation 2009 Operation Base Back Functions To operate the Base Back functions Press amp hold the Up or Down arrow button for the desired function Note The table automatically stops at its maximum and minimum height In the event of a malfunction press the Stop button to terminate movement Back Function Base Function Stop Back Function Equipment Alert If the table s weight limit is exceeded you will hear a beep and the function will be disabled If the problem occurs with a normal load contact your service technician Base Function Stop 8 Midmark Corporation 2009 Home Function The Home function automatically lowers the table to approximately 20 51 cm To activate the Home function Press amp release the Home button Note In the event of a malfunction press the Stop button to terminate movement Home Stop Midmark Corporation 2009 Quick Exam Function The Quick Exam function automatically commands the table seat height to a programmed position To program the Quick Exam function a Press the Base Up button to move the table to the desired position b Press amp hold the Quick Exam amp Base Up buttons simultaneously for three seconds Note You will hear a brief chirp when the new Quick Exam position is saved Quick Exam To activate the Quick Exam function
4. Barrier Freee Examination Table For Models 625 001 003 625 005 006 7 N e snm U ag rs G U id e 003 2020 00 Rev K 10 25 13 Style C Product Information Dealer Date of Purchase Model Serial Number Midmark Authorized Service Company Model Serial Number Label Located on the Back Mounting Frame exact location may vary Midmark Corporation 2009 L lt Table of Contents Important Information EHI OURS DRM a de ao ai en IM E 4 Transportation Storage Conditions EEUU Viu CR PRXTER UPPER Puta 4 Compliance RALIS D iNended USE ebben See 6 CMOS RO RU OR r HH BNN mm 6 Steeg 6 ES Sal EHI lee 6 aica ANR UE Ka e eeem z 7 Operation Base Back mic 8 EE 9 Quick Exame Function L LE EEE EEE ESLE e SEKE SAS ak e agg KA KAKA Ka KA ka ka a ka ka a a ka ka a ka ka ka ka a ka 10 Exam Assistante Drawer System TRUM 11 Faber FONE TESI STD TEE 12 eet 13 Footrest amp Treatment Pan Emm 14 Drawer Heater optional avdexsiiciexbirko Air cepa niches date eas Dior basa bi we Ead bur ne 14 LE RTT TELE 15 Duplex aic tI Nm 16 Maintenance erer dt rm 17 AIME a en a bo le tnt 17 Preventative Maintenance eene EE KEKE EEE KEKE EK KEK KAK Ka Ka KA a ka kra ka a kk a 17 Specifications Weights Dimensions Electrical Specifications 18 Model Identification Compliance Chart 19 Fandag or MOUOM amp bun zak aS yy en oi nono 20 Warranty Information
5. EWE E TCI 22 3 Midmark Corporation 2009 Important Information Safety Symbols DANGER Indicates an imminently hazardous situation which will result in serious or fatal injury This symbol is used only in the most extreme conditions WARNING Indicates a potentially hazardous situation which could result in serious injury Caution Indicates a potentially hazardous situation which may result in minor or moderate injury It may also be used to alert against unsafe practices Equipment Alert Indicates a potentially hazardous situation which could result in equipment damage Note Amplifies a procedure practice or condition A Type B Applied Part Consult User Guide for 11 Proper Shipping Orientation important information Er Maximum stacking height Protective earth ground M palletted units Duty Cycle motor run time v Fragile 30 seconds ON 5 minutes OFF san j Euse rating specification Emergency Stop 4 444 Keep dry Patient weight limit 295 kg 650 Ibs Transportation Storage Conditions Ambient Temperature Range 41 F to 104 F 5 C to 40 C Relative Humidity sise 10 to 90 non condensing Atmospheric Pressure VV 500hPa 49 atm to 1060hPa 1 04 atm 4 Midmark Corporation 2009 Compliance Information FCC Compliance Statement This equipment has been tested and found to comply with the limits for a class A digital device pursuant to
6. See Range of Motion amp Dimensions page Weight of Table w upholstery w packaging amp skid no uph Uph w packaging shipped separately 470 lbs 213 kg 487 lbs 221 kg 45 Ibs 20 kg Power Cord Length 8 ft 244 cm Electrical Requirements Foot Hand Control Voltage See Regulatory Compliance Charts 14 VAC SELV Safety Extra Low Voltage Duplex Receptacles maximum load 115 VAC 5A 50 60 Hz Fuses IEC inlet fuses 2 F1 amp F2 on main PC board F3 on main PC board F4 on main PC board Models w drawer heaters distribution board fuses 2 6 3A 250V Type T 5 x 20 mm 10A 250V Type T 5 x 20 mm 160mA 250V Type T 5 x 20 mm 6 3A 250V Type T 5 x 20 mm 800mA 250V Type T 5 x 20mm Duty Cycle Motor Run Time Receptacles Drawer Heater Intermittent Operation 30 seconds ON 5 minutes OFF Continuous Operation Classifications Class 1 Type B Applied Part Protection against ingress of fluids IPXO Foot Control only IPX1 WARNING Equipment not suitable for use in the presence of a flammable anesthetic mixture 18 Midmark Corporation 2009 EEL Hiel EOIUU091 BuiusiuJn j euloH JO neang eruJoJije2 YUM seri duuoo jeu ejqejreAe si Aaysjoudn jeuondo LL OWL ZL 0Z1 6 0Z186 JOOS suone nDes jo epo eluJojije pue Zii unejng eoruuoe Buiusiuun 4 euiop Jo neeung eriuJoJi e2 YUM seipduoo Aisysjoudn y SPUET ep
7. ectric shock or burns to patient Electromagnetic Interference This product is designed and built to minimize electromagnetic interference with other devices However if interference is noticed between another device and this product e Remove interfering device from room e Plug chair into isolated circuit e Increase separation between chair and interfering device e Contact Midmark if interference persists Disposal of Equipment At the end of product life the chair accessories and other consumable goods may become contaminated from normal use Consult local codes and ordinances for proper disposal of equipment accessories and other consumable goods 6 Midmark Corporation 2009 L lt Safety Instructions Caution Be sure that all personnel and equipment are clear of the table before activating any function Failure to do so could result in personal injury At the table s lowest height 18 in 45 7 cm the clearance between the bottom of the drawer and the floor is approximately 2 1 in 5 4 cm Make sure patient esp feet and all objects are clear of this area before lowering table If the table malfunctions immediately release foot pedal unplug the table power cord and assist the patient from the table If table continues to malfunction call for service Failure to comply with these instructions may result in injury to patient and or damage to equipment Approx 2 1 in 5 4 cm
8. is radio transmitter may only operate using an antenna of a type and maximum or lesser gain approved for the transmitter by Industry Canada To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication Conform ment la r glementation dIndustrie Canada le pr sent metteur radio peut fonctionner avec une antenne dun type et dun gain maximal ou inf rieur approuv pour l metteur par Industrie Canada Dans le but de r duire les risques de brouillage radio lectrique l intention des autres utilisateurs il faut choisir le type dantenne et son gain de sorte que la puissance isotrope rayonn e quivalente p i r e ne d passe pas l intensit n cessaire l tablissement dune communication satisfaisante 5 Midmark Corporation 2009 Intended Use This exam table is intended to be used as a chair table to provide positioning and support of patients during general examination procedures conducted by medical professionals Electrical Requirements e Caution When using high frequency surgical devices or endocardial catheters e Use non conductive material to insulate patient from metal portions of the chair e Consult operating instructions for the device before using in conjunction with drawer or upholstery heaters Failure to comply may result in el
9. k Corporation 2009 iE Duplex Receptacles The duplex receptacles on each side of table provide power for accessories used during medical procedures There are two circuit breakers located under the seat section If the receptacles maximum load is exceeded the circuit breakers interrupt power to the receptacles Alb Ore i Bor ro PR EA ENE EN 115 VAC 5 amps To reset the circuit breaker Push circuit breaker switch Tripped no power Circuit Breakers Reset power NE MA7992i 1 6 Midmark Corporation 2009 Maintenance Calling for Service Note Model serial number information is required when calling for service If service is required contact your authorized Midmark dealer To contact Midmark directly 1 800 MIDMARK 1 800 643 6275 8 00 am until 5 00 pm Monday Friday EST excluding standard U S holidays www midmark com The upholstery is resistant to most medicinal type stains but may be damaged by solvents and dyes Immediately remove any fluids spilled on the upholstery Cleaning Equipment Alert Upholstery Wash your upholstery weekly with a mild liquid soap and water mixture rinse with clear water and dry completely to remove disinfection cleaner build up Disinfect your upholstery with a solution of standard bleach and water mixed 1 in 10 1096 or chlorine based cleaners Follow this with a clear water rinse and thorough drying of materia
10. l See current CDC Guideline for Disinfection amp Sterilization in Healthcare Facilities To minimize damage caused by disinfectant cleaner residue build up do not allow disinfectants to pool on the upholstery surface Once the approved contact time has been obtained remove and dry excess liquid remaining on the surface Detailed care and maintain instructions are available in your user guide located on the CD that came with your table or by referring to Upholstery Care and Maintenance Painted Metal Plastic Surfaces Clean the painted metal and plastic surfaces weekly using a clean soft cloth and mild cleaner Periodic applications of common furniture wax will ease cleaning and maintain the finished luster of the surfaces Preventative Maintenance Periodically inspect the following areas Power cord s should be free of cuts or other visible damage All fasteners should be in place and tightened securely All mechanical functions should operate properly Periodically lubricate the back hinge to maintain quiet smooth operation use light machine oil Have an authorized service technician inspect your equipment every six months 1 Midmark Corporation 2009 L lt Specifications Patient Weight maximum Weights Dimensions Electrical Specifications Specifications Chart 650 Ibs 295 kg Paper Roll maximum size See Paper Roll amp Tear Strap page Range of Motion amp Dimensions
11. mal use and service Midmark s obligation under this warranty is limited to the repair or replacement at Midmark s option of the parts or the products the defects of which are reported to Midmark within the applicable warranty period and which upon examination by Midmark prove to be defective APPLICABLE WARRANTY PERIOD The applicable warranty period measured from the date of delivery to the original user shall be one 1 year for all warranted products and components EXCLUSIONS This warranty does not cover and Midmark shall not be liable for the following 1 repairs and replacements because of misuse abuse negligence alteration accident freight damage or tampering 2 products which are not installed used and properly cleaned as required in the Midmark Installation and or Installation Operation Manual for this applicable product 3 products considered to be of a consumable nature 4 accessories or parts not manufactured by Midmark 5 charges by anyone for adjustments repairs replacement parts installation or other work performed upon or in connection with such products which is not expressly authorized in writing in advance by Midmark EXCLUSIVE REMEDY Midmark s only obligation under this warranty is the repair or replacement of defective parts Mid mark shall not be liable for any direct special indirect incidental exemplary or consequential dam ages or delay including but not limited to damages for loss
12. o SI Jojeau J9MeJp 0 l or Jed M yoeg eseg qe uonounj oM 900 SZ9 UD orad M joeg eseg v o qe UONOUNJ OM EN S OJ UOO SS9 9JIM Jojeou JOMEJP jj DIAjad ch s se oe1doo9l M yoeg eseg 9 qe uonounj o GLL VA Midmark Corporation 2009 2W3 06IA L L093 0 OL 66 z 0ogo 110909 TUE L L0909 9 Vd3N N3 1n N3 VS9 NVO uonduoseq sBunes e21329 3 0J Seijduio2 Jojeou JOMeIP X un Ajad se oe1doo91 M 4oeg oseg e qe uonounj o Model Identification Compliance Chart L lt Range of Motion amp Dimensions ha 37 5 in 94 1 3 cm Quick Exam Height Programmable set by the user Home Height cm 20 5 in 50 8 1 3 cm 80 57 Pelvic Tilt Max 7 2 Min 1 5 pum En MA8023i 0 Midmark Corporation 2009 Range of Motion amp Dimensions continued 59 5 in Up to 151 1 cm 16 in 69 9 cm 72 4 cm 75 5 in 191 8 cm Standard 8 ft 2 4 m Optional 3 ft 91 cm E E MA8369i 8 6 in 115 5 cm 21 8 cm 1 Midmark Corporation 2009 Warranty Information SCOPE OF WARRANTY Midmark Corporation Midmark warrants to the original purchaser its new Alternate Care products and components except for components not warranted under Exclusions manufactured by Midmark to be free from defects in material and workmanship under nor
13. of profits or loss of use NO AUTHORIZATION No person or firm is authorized to create for Midmark any other obligation or liability in connection with the products THIS WARRANTY IS MIDMARK S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WAR RANTIES EXPRESSED OR IMPLIED MIDMARK MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PAR TICULAR PURPOSE THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS Midmark Corporation 2009 Notes 3 Midmark Corporation 2009 Language of origin English Midmark Corporation For contact information go to Wall si VN ee www midmark com Because we care 2009 Midmark Corp 60 Vista Drive Versailles OH 45380 USA 1 800 643 6275 1 937 526 3662 midmark com
14. part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense Any modifications to this product may violate the rules of the Federal Communications Commission and make operation of the product unlawful IC Compliance Statement Interference This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible den compromettre le fonctionnement Antennas Under Industry Canada regulations th

Download Pdf Manuals

image

Related Search

Related Contents

添付資料  Chief KPV110B  GFK2789D WV3 HW Ref Manual  Operating Instructions G-BH7 2BH72 2BH73  User Manual (English) - MYRATEC® – Myrateche.com  BEA 80.0000.02 Switch User Manual  Oracle Audio Technologies E10898-02 User's Manual  EASY PREPARATION PREPARACIÓN SENCILLA PRÉPARATION  HP Officejet 8610 User Guide – PTWW  発注仕様書2  