1. V positive V common V negative yi Figure 1 Typical Installation Front Panel View CHAPTER 2 INSTALLATION AND SETUP Left End View To power source 10 to 36 Vdc Analog A1 A2 A3 A4 Current gt k gt 4 4 Sensor To alarm To optional CWR CS indicator Current Sensor Analog Input DC or AC voltage only Right End View Terminal eat MicRO AIDE j To telephone line for optional internal modem 300 to 115 200 Baud Figure 2 Typical Installation End Panel Views MicRO AIDE CWR 22xT USER MANUAL 1 With the power off connect the power source positive and negative conductors to either pair of screw terminals labeled B and N respectively They are located along the left end panel of the recorder 2 Connect the PC to the DE 9 male connector labeled Terminal Use the cable provided by MICRO AIDE or a DE 9 to DE 9 straight through cable Figure 7 on page 85 illustrates the proper wiring of the cable Caution Do not attempt to connect the PC to the female DE 9 connector labeled Current Sensor Damage to the recorder may result Note The factory default setting for the Terminal Port is 38 400 Baud Refer to the procedure entitled Terminal Port Baud Rate on page 19 for details
2. CONNECTOR AMP 746285 4 PIN FEMALE F W 2 6 PIN FEMALE F W 3 STRAIN RELIEF RIBBON 14 CONDUCTOR AMP 499252 9 STRAIN RELIEF RIBBON 16 CONDUCTOR AMP 499252 JUMPER COMB WEIDMULLER 8 10 POSITION 2 47250 CONNECTOR SCREW DOWN FEMALE 3 POSITION WEIDMULLER 71633 CONNECTOR SCREW DOWN FEMALE 4 POSITION HEETMETAL HEETMETAL CONNECTOR SCREW DOWN FEMALE 8 POSITION WE H 71634 71638 CREW DOWN FEMALE 12 POSITION 71642 BASE END PANEL HEETMETAL HEETMETAL USER MANUAL MOUNTING BRACKET COVER CWR 22xt Qty OPT MicRO AIDE CWR 22xT USER MANUAL CWR 22xt Subassemblies PA85 0059 00 Processor PCB M A Part No P 85 0059 00 C 220PF 00 Q 1MF 00 C 47F 00 c 1MF 00 CE220MF 00 CE220MF 01 CE2200MF 00 CT4 7MF 00 CT10MF 00 CT33MF 00 D 1N4004 00 D 1N5822 00 D 1N914 00 D MBR160 00 DZ1N5359B 00 F 225001 00 FH111501 00 H TP 101 00 JA520250 00 JFDB09S 00 JMDE09PL 00 JPWW36 1R 01 JRICO 203 00 JRICO 326 00 JRIDHIOLP 01 Description MFG Part No PCB PROCESSOR CWR 22xt CAPACITOR 220PF 5 100V CERAMIC AVX SR211A221JAA CAPACITOR 1MF 50V CERAMIC CAPACITOR 47F 5 5V SUPER CAP ELNA DH 5R5D474 APACITOR 1MF 50V CERAMIC c CAPACITOR 220MF 50V AXIAL ELECTROLYTIC ILLINOIS CAPACITOR 227TTAO50
3. i i N r 5 5 1 JW151366 00 CONNECTOR MALE 12 POSITION RIGHT ANGLE WEIDMULLER 151366 A B 5 x 5 5 B R 3 K G5V 2 00 RELAY 5V DIP OMRON G5V 2 Hl DC5 B 4 B 5 N 5 5 5 r 5 1 L 20 100K 00 NDUCTOR 10UH ALLIED AC20 100K l 7 7 7 7 F 1 L WFB 3 0 00 CHOKE WOUND FERRITE BEAD FAIR RITE 2943666631 5 5 2 Q 2N3906 00 TRANSISTOR PNP 2N3906 Q PN2222A 00 TRANSISTOR TO 92 PN2222 QR79L05 00 VOLTAGE REGULATOR 5V TO 92 NATIONAL 79L05 QRLT1171 00 VOLTAGE REGULATOR SWITCHING TO 220 LINEAR TECHNOLOGIES LT1171CT R 4 70HM 00 RESISTOR 4 7 OHM 5 25W 2 R 180HM 00 RESISTOR 18 OHM 5 25W 2 R 1000HM 00 RESISTOR 100 OHM 5 25W 1 R 3900HM 00 RESISTOR 390 OHM 5 25W 3 R 4700HM 00 RESISTOR 470 OHM 5 25W l R 1K 00 RESISTOR 1K 5 25W 2 R 4 7K 01 RESISTOR 4 7K 5 25W 5 5 19 R 10K 00 RESISTOR 10K 5 25W 4 R 16 5K 00 RESISTOR 16 5K 1 25W R 30 9K 00 RESISTOR 30 9K 1 25W R 100K 01 RESISTOR 100K 1 25W R 221K 00 RESISTOR 221K 1 25W 8 R 1 4M 00 RESISTOR 4M 1 25W 4 R1OM 01 RESISTOR 10M 1 25W 8 RA25010 00 ARRESTOR GAS 3 TERMINAL CP CLARE PMT 3 310 25010 RP5K 00 POTENTIOMETER 5K 1 TURN TOP ADJUST BI TECHNOLOGIES 72PR5K RP10K 01 POTENTIOMETER 10K 20 TURN TOP ADJUST BI TECHNOLOGIES 67YR10K N Z i i i i 2 RN10S4 7K 00 RESISTOR NETWORK 10 PIN SIP 4 7K 2 BI TECHNOLOGIES L101C
4. Alternatively press the Browse key to jump to a different input Specify the Input Number by pressing the appropriate numeric keys Leading zeros are not required Press the Enter key to jump directly to the selected input The first line also includes four place holders for variables Variables are physical inputs or other Virtual Inputs The procedure for assigning variables is described below Each Virtual Input can selectively operate the internal relay of the CWR 22xt Press the Enter key to toggle the existing Relay setting from No to Yes or vice versa Virtual Input records can be transmitted to a remote maintenance facility provided the CWR 22xt is equipped with an internal modem Press the Enter key to toggle the existing Dial setting MicRO AIDE CWR 22xT USER MANUAL Assigning Variables A variable can be any valid Digital Analog or other Virtual Input To assign variables complete the steps listed below 1 Press the left and right arrow keys to locate the highlight in a place holder field 2 Press the Enter key 3 Press the Alpha key until the desired input type designator appears i e D A or V 4 Enter the desired Input Number by pressing the appropriate number keys 5 Accept the new entry by pressing the Enter key 6 Repeat the preceding steps if additional variables are required The final step is to select the states that each variable assumes in defining a Virtual Input Selecting States A Virtual Input can
5. Analog DC Voltage 3 scales 25 5 51 1 255 Analog AC Voltage 2 scales 25 5 255 Analog Current 2 scales optional 25 5Adc 25 5Aac Event Validation Times Digital 001 to 32 767 seconds compatible with fixed rate flashing circuits Analog fast and slow filter settings writes first dav newest data over Memorv writes oldest data RS 232 Port Quantitv 1 for use with a PC Emulation ANSI Baud Rates 300 600 1200 2400 4800 9600 19 200 38 400 57 600 115 200 Bit Format N 8 1 Tvpe Non volatile Event Records and Setup Database are stored in flash memorv chip Storage Longevitv Infinite with power off Rated for 1 million write operations MicRO AIDE CWR 22xT USER MANUAL Analog Input Accuracy Connectors continued Password Protection Typical Vdc 1 full scale Power Administrative Level Typical Vac 1 5 full scale Detachable screw down 4 posi Access to all functions limit Typical Current 2 full scale tion 12 to 22AWG 8 characters Dual B and N terminals Restricted Level Analog Limit Values Alarm Relay Access to Event Record and Voltage Detachable screw down 3 posi Setup Database viewing only tion 12 to 22AWG limit 8 characters Separate high and low limits in HON 12 10 multiples of 1V or 1V N O N C and common Passcode i Protects against alterations to Current AM Telephone Line Setup Database via front panel Separate high and low limits in RJ 11 female limit 8 di
6. Chassis Fully enclosed anodized aluminum Externally accessible keypad LEDs and connectors Electrical All components mounted on conformal coated internal PCBs Power Voltage Range 10 to 36Vdc Consumption Typical 4W Maximum 5W with Modem PCB Isolation Power Minimum 3800Vdc from B and N terminals to chassis and inputs Digital Inputs Minimum 3800Vdc to any terminal Analog Inputs Minimum 3800Vdc to any terminal Input to Adjacent Input Digital minimum 3800Vdc Analog minimum 3200Vdc Internal Modem optional Designed to meet FCC part 68 standards Capacities Inputs Digital 18 all opto isolated Analog 4 total voltage or current optional Virtual 8 user assigned Outputs Relay 1 form C rated for 2A at 24Vdc or 1A at 125Vac maximum switching capacity of 125VA or 60W service life 1 million electrical typical Event Storage Standard 190 304 records expandable to 380 864 records Memory Full 129th day over Capacities continued Liquid Crystal Display Characters 40 total on 2 lines Character Set A Z upper and lower case 0 9 various symbols Viewing Area 2 9 by 5 Front Panel Keypad Quantity 20 keys Keys 0 9 Browse Alpha Setup Esc Enter Decimal left right up down Inputs Input Impedance Digital minimum 5KOhms opto isolated Analog minimum 10MOhms Range Digital Input On 5 to 36Vdc Digital Input Off 0 to 2Vdc
7. High Current Sensor 4 inputs 1 to 20Adc or Memory Expansion Aac 40 0216 380 864 Event Records Battery Charger Monitors CSI 1 Charge Status Indicator single input monitors voltage and current Voltage Detectors FVD 2 Failed Voltage Detector 2 inputs 5 to 48 Vdc 5 to 36 Vac high and low limit values Light Out Detectors FLD 2 Failed Lamp Detector 2 inputs 3 to 11 lamps each input DC or AC lamp current compatible with all recorders Jumper Combs 147250 Weidmuller 10 position shorting clip used to connect multiple inputs to a single point e g common return Mounting 31 0001 19 rack mounting brackets 31 0002 23 rack mounting brackets 31 0003 Wall mounting brackets included Cables DE 9 to DE 9 included Contact MICRO AIDE when ordering any options or accessories Purchase Order may list requested items as described in the above MicRO AIDE CWR 22xT USER MANUAL User Notes APPENDIX C CWR CS CURRENT SENSOR Introduction The CWR CS is an optional accessory that can be used with any MICRO AIDE CWR series Event Recorder It is equipped with four general purpose current sensing inputs Any of the first four Analog Inputs i e Al A4 of the CWR 22xt can be individually configured to measure either AC or DC current Refer to the section entitled Analog Configuration A on page 23 The CWR CS provides the hardware by which the voltage sensing Analog Inputs of the recorder are converted to c
8. Lite On Bat Norm Alrm Off lite OFF Bat Norm Alrm OEF lite Omi Bat Norm jalla hei Lite On Bat Bad Alem Off Lite On Bat Bad Alem Off Lite Off Bat Bad Alrm Off lite Off Bat Bad Alrm On Assigning States to Virtual Inputs Selecting States Before proceeding further the table of state selection fields must be understood Each Virtual Input will have its own data table However the basic structure of each table will remain the same Refer to the sample data labeled Assigning States to Virtual Inputs on page 29 Each row lists from left to right the Input Numbers that are assigned to each variable e g labeled D18 D07 and A047 Unassigned variables are labeled The last column of the third line lists the Input Number of the Virtual Input being defined e g labeled V03 Directly below the Input Numbers on the fourth line of text is listed the Input Identifier for the variable For the sample data shown the Input Identifiers are labeled POK Rly App Lite and Battery The Virtual Input has retained its default Input Identifier labeled VInput03 The remaining lines of text will vary with the number of assigned variables One variable will list two lines of text Two variables will list four lines of text Three variables example cited will list eight lines of text Four variables will list sixteen lines of text Each line will specify a state for each of the assigned varia
9. 190 304 Event Records Event Records can be logged for 128 distinct days Event Records are stored in Flash Memory devices that do not require a battery power source Records are retained even if power is removed Setup data and Event Record data can be easily and quickly transferred to a PC file Relay signals in the range from 5 to 36 Vdc can be sensed by the Digital Inputs Both positive and negative voltages can be sensed Attaching the recorder to an event generating circuit is completely non intrusive to the circuit This is ensured by the high impedance nature of the design Each Digital Input utilizes opto isolation technology to provide ground isolation of at least 3800 Vdc Every Event Record includes a measurement for each of four Analog Inputs Analog Inputs can range from 51 1 V 1V scale to 255 V 1 V scale DC or AC Analog Inputs are tested against separate High and Low Limit Values that are assigned by the user Crossing either Limit Value will create an Event Record Current levels as great as 25 5 Adc or Aac can be monitored by using the optional CWR CS Any Analog Input can optionally be configured to report train speed User assigned Limit Values can be used to report excessive speed conditions in the form of an Event Record The FLD 2 Failed Lamp Detector can be used at crossings to detect burned out bulbs Event Detection Times can be set by the user on an input by input basis Default values are provided as an
10. 20 TURN HORIZONTAL SIDE ADJUST BI TECHNOLOGIES 68PR1K OP AMP QUAD 85C ANALOG DEVICES OP490GP SEE NOTE Oty MicRO AIDE CWR 22xT USER MANUAL User Notes Material Return Policy In the event the customer identifies a malfunction in any product call or write MICRO AIDE and obtain a Return Material Authorization RMA number from the customer service department Return the product to MICRO AIDE freight prepaid with a note in warranty repair or a purchase order out of warranty for the repair listing the following information e RMA number from MICRO AIDE e Return shipment address Name and telephone number of person familiar with the problem Brief description of the problem include any printouts that may have a bearing on the problem e Method of payment for repair costs out of warranty Send product to the following address MICRO AIDE CORPORATION 685 Arrow Grand Circle Covina CA 91722 Tel 626 915 5502 Fax 626 331 9484 E mail support micro aide com Limited Warranty MICRO AIDE warrants its products to be free from defects in material and workmanship for a period of five 5 years from the date of shipment This warranty is in lieu of any other warranty expressed or implied In no event shall MICRO AIDE be held liable for incidental or consequential damage resulting from 1 the use of any of its products or 2 any alleged breach of this warranty provision MICRO AIDE s liability shall be
11. Event Record Format Browse Mode Records Status Flash Setup Mode Alphanumeric Editing Procedure s 36 CHAPTER 5 APPENDIX A APPENDIX B APPENDIX C APPENDIX D Clock CSync UName ENames INames DTimes Analog Virtual Speed PCode MIEN Modem optional Baud Diag RESET MAINTENANCE Introduction Working Inside the Recorder FAMA Adjusting the LCD Contrast Switch Settings Analog Input Switches SW1 Firmware Option Switches SW2 Installing the Optional Modem Replacing the Fuses Reconnecting the Internal Cables Diagnostic Testing Checksum Test Program Memory C Flash Memorv Test F Modem Test M Keypad Test K Relay Test R System Events Upgrading the Firmware HyperTerminal Procomm Plus Trouble shooting Guide TECHNICAL DATA Specifications Terminal Port Cable OPTIONS AND ACCESSORIES CWR CS CURRENT SENSOR Introduction Key Features Installation and Setup BILLS OF MATERIAL TABLE OF CONTENTS 83 85 89 89 MicRO AIDE CWR 22xT USER MANUAL CWR 22xt Bill of Material CWR 22xt Subassemblies PA85 0059 00 Processor PCB PA85 0063 00 Keypad PCB PA85 0083 00 Modem PCB CWR CS Bill of Material CWR CS Subassemblies PA85 0038 00 Quad Current Sensor PCB IGESN GENERAL DESCRIPTION Introduction Since 1988 MICRO AIDE has provided the rail signal industry with a broad ra
12. Event Records that are time stamped before the assigned End Time for the day selected as the End Date will be issued by the Query Command The End Time can be assigned any value from 00 00 00 to 23 59 59 The default setting is always 23 59 59 The End Time must be entered in military format Include Details The CWR 22xt can format Event Records in either of two ways Press the Spacebar to toggle the Include Details setting between Yes and No Both options are described below Yes The status of each Digital Input the level of each Analog Input and the status of each Virtual Input is listed with data concerning the input that created the record This is the default setting of the recorder Two lines of text are required by this record format e No Only information concerning the input that created the record is listed A single line of text is required by this record format A complete explanation of Event Record formats is included at the end of this chapter Refer to the section entitled Event Record Formats on page 46 Note Note CHAPTER 3 OPERATION Reverse Order The Reverse Order option can be set to either No default setting or Yes The default setting will result in the oldest records being issued first If enabled the Reverse Order option will issue the most recent records first They will be followed by older records In either case Event Records are always issued in chronological sequence Report Type The
13. On The Digital Input voltage is in the range from 5 to 36 Vdc The Analog Input level is outside the acceptable range as defined by the region between the Limit Values refer to Figure 4 on page 25 The Virtual Input evaluates to a true logic state MicRO AIDE CWR 22xT USER MANUAL e Off The Digital Input voltage is less than 2Vdc The Analog Input level is within the accept able range as defined by the region between the Limit Values The Virtual Input evaluates to a false logic state The procedure used to define Virtual Inputs is described in the following two sections Assigning Variables An array of fields similar to the following will be displayed after selecting the Virtual Inputs command In the example cited only variables for Virtual Input V3 have been entered The other fields have retained their factory default settings Only the first six Virtual Inputs are listed Virtual Input Parameters Input Function of Relay Dial Out v02 v03 A04 v04 v05 V06 Fl to edit virtual output function Assigning Variables to Virtual Inputs To assign variables perform the following steps in the order described 1 Position the highlight anywhere in the row identified by the Virtual Input to be programmed e g V3 Then move the highlight within the row to the extreme left most column 2 Assign the first variable by entering Dnn An or Vn where n is 1 to 18 for Digital Inputs 1 to 4 for Ana
14. Simon 5 Of wr Fail Alarm On baysal RORE apar Ore Input04 Off lnputuis OLE lnputbes O tipjoxbteld 7 8 Qi ie Inputues Off lt assss lt s lt s0 X X D D D D D D D D D D The Live Status report includes a header that lists the present time and date Digital Inputs with their corresponding Input Identifiers are listed in the first column To the immediate right of the Input Identifier is the Event Name that identifies the input s present state The next three CHAPTER 3 OPERATION columns list the Input Identifiers measured values and corresponding Event Names of each of the four Analog Inputs The eight Virtual Inputs are listed below the Analog Inputs The sample data indicates that the XR 1 and XR 2 relays are Active and Idle respectively The GateDwnl and GateDwn2 inputs are Down and Up respectively X Litel is On and X Lite2 is Off The ac power connected to Analog Input A1 is low at 85 Vac and is therefore reported as being in a Fail state The Batteryl potential is 11 2 Vdc which is considered to be Normal The Train Speed Monitor is enabled for Analog Input A4 An excessive speed of 27 mph is indicated Finally the low ac voltage reported on Analog Input A1 has resulted in a pending power fail alarm The alarm condition has been assigned to Virtual Input V1 identified as Pwr Fail and is referred to as Alarm On The Live Status command can be very useful in verifying that inputs are wired and
15. The other Digital Inputs are idle The next four bit positions are used to indicate the state of each Analog Input Finally the last eight bit positions represent the Virtual Inputs In the sample data cited above Analog Inputs A1 through A4 are inactive Virtual Inputs V1 and V8 are active Event Records that satisfy the user selected date and time criteria are listed after the header Records always include five data fields separated by a single comma From left to right the fields include the time date Input Name status and Input Number The input status is always listed as either ON or OFF The assigned Event Name is not used By convention CSVs that may contain a comma character must be enclosed by a pair of quota tion marks Refer to the Unit Name Input Names and status labels shown above A name that contains a quotation mark will be indicated by an additional quotation mark The Input Number listed in a CSV record is altered to exclude letter prefixes e g A and V Table 3 lists the translation method employed Input Source CSV Input Number D1 to D18 Digital 1 to 18 A1 to A4 Analog 19t022 V1 to V8 Virtual 23 to 30 S1 Svstem Power 31 Table 3 CSV Input Numbers Inputs The Inputs field allows the user to inspect Event Records from specific inputs The default setting Inputs field is blank will issue records from all inputs To select specific inputs a valid Input Number must be entered Digi
16. actual circuits are wired to the recotder s input connectors The CWR 22xt also includes eight Virtual Inputs Contrary to physical inputs Virtual Inputs are defined by the user for the purpose of detecting failure or alarm conditions among the physical inputs Refer to the section entitled Virtual Inputs V on page 27 All inputs regardless of type share one common programming characteristic The user can define a unique Input Name Input Identifier and Event Name pair to each input The Input Name can be any combination of alphanumeric characters not exceeding twenty total The Input Name appears in each Event Record created by the input in question It is the primary means by which inputs are distinguished The Input Identifier can be thought of as an abbreviated name It is limited in length to eight alphanumeric characters It too appears in the Event Record It is primarily used to distinguish Event Records displayed on the LCD panel of the recorder Several of the setup commands use the Input Identifier rather than the lengthier Input Name to reference inputs The Event Name pairs are described in the preceding section As many as eighteen Event Name pairs can be defined by the user Each pair is identified by a number ranging from one to eighteen After the pairs are defined the Input Names Identifiers command is used to assign Event Name pairs to inputs The Event Name pair can be assigned by using either of two methods The Spacebar
17. be thought of as a logical relationship shared by one to four inputs Accord ingly the state a Virtual Input assumes is dependent upon the state of each assigned variable It follows that a Virtual Input dependent upon one variable is defined by a combination of two states Two variables yield a combination of four states Three variables yield eight states Four variables yield sixteen states Selecting states involves the assignment of a Virtual Input state for each combination of variable states Press the Setup key after all of the variables have been assigned Data similar to the following will be displayed D18 DO A04 V03 Off Off Off OFF For the sample data cited above three of four possible variables have been assigned to Virtual Input V3 The first line of text lists the assigned variables by Input Number It also lists the selected Virtual Input The second line of text lists a specific combination of states for the assigned variables The tight most field indicates the state the Virtual Input assumes for the combination of variable states listed Variable and Virtual Input states always assume one of two values Each value is described below e On The Digital Input voltage is in the range from 5 to 36 Vdc The Analog Input level is outside the acceptable range as defined by the region between the Limit Values refer to Figure 4 on page 25 The Virtual Input evaluates to a true logic state Off The Digital Input voltage i
18. both parameters is described in the following sections Detection Times In the sample data shown above the Detection Times are set to the factory default value of 3 000 seconds The range of valid Detection Times is 0 to 32 767 seconds A value of zero prevents the Digital Input from logging events Use the decimal point key to enter fractional values The Detection Time of inputs assigned as sensors in the Train Speed Monitor feature cannot be altered They are set to a fixed value of 005 seconds Set the Detection Times to values slightly greater than the longest expected bounce time of the relay contacts This will insure that noise or transient induced voltage changes are not recorded and that legitimate short duration events will be logged The Detection Time assigned to a Digital Input enabled for flashing operation represents a special case requiring additional explanation The correct programming procedure is described below Flash Enable The CWR 22xt is able to log Event Records from flashing circuits A typical flashing event is created by the operation of a crossing light or approach signal Each time the light flashes a new pulse is seen at the Digital Input The recorder should only log the start and end events not an event for each pulse Assigning the proper Detection Time to the input and enabling the input for flashing operation solves the problem of multiple flash events when only a single pair of events is actually required F
19. can be repeatedly pressed when the highlight is located within the OnEvent OffEvent field until the desired pair is listed Alternatively the number of the required Event Name pair can be entered in the last column CHAPTER 2 INSTALLATION AND SETUP A typical response to the Input Names Identifiers command is shown below Only the first three Digital Inputs have been listed Analog Inputs follow Digital Inputs The Virtual Inputs follow the Analog Inputs Input Names Identifiers Input Name ID OnEvent OffEvent Event Pair DOL bi ical Tron Oil DInput01 On Off il DO2 Digital Input 02 DInput02 On Off il DOS Digital wee OS DInput 03 On Off il Fl Next Page F2 Prev Page Two data screens are required to list all 30 physical and Virtual Inputs To advance to the next screen press the F1 function key To return to the previous screen press the F2 function key Virtual Inputs V Virtual Inputs are a unique feature only found in MICRO AIDE s family of CWR Event Recorders The CWR 22xt is a powerful general purpose recording device that can be used to satisfy the data logging demands of a variety of applications An Event Recorder is frequently used to gather data on a failure condition thought to exist in a relay based control circuit The failure condition may occur intermittently The need to log data over a significant period of time will often impose an additional requirement upon the recorder The suspected failure can often be def
20. day of week is automatically calculated by the CWR 22xt based upon the day month and year selected by the user Press the Esc key after the changes have been made The following message will be displayed Change the clock now Yes No To complete the command press the Enter key after selecting the desired option MicRO AIDE CWR 22xT USER MANUAL Tip Note CSync The real time clock used by the CWR 22xt can be synchronized to an external source by use of the Clock Sync feature Refer to Clock Sync Input on page 21 for additional details To synchronize the real time clock a Digital Input must be assigned as the Clock Sync Input The following message will be displayed after selecting the CSvnc command Clock Sync Input The field labeled is the place holder for the Digital Input number A valid Input Number may instead be listed if one was previously assigned Press the Enter and then the Alpha key to assign an input or change the existing assignment Press the appropriate number keys to select the Input Number Complete the command by pressing the Enter key or ESC key to accept the new assignment or ignore the change respectively To disable the Clock Sync feature press the Enter key and then the Alpha key The displayed Input Number will return to the setting Complete the entry by pressing the Enter key again UName The UName command is used to assign a unique name to each CWR 22xt recorder Refer to
21. fails on all inputs Verify polarity of test voltage is applied correctly Verify Detection Times are not set to zero Check inputs using View Events command Event Records are not being created on some inputs Check wiring especially polarity Set Detection Time to shorter value Verify Detection Times are not set to zero Flashing Inputs create multiple Event Records Enable flashing status for inputs Set Detection Time to a longer value Analog Input AC source measures 0 Analog Input is configured for DC change to AC Analog Input DC source measures correctly but reports AC units Analog Input is configured for AC change to DC Negative Analog Input voltage is not reported measures 0 Analog Input Range is set to 51 1Vdc change to setting AC analog readings are not stable Reassign the analog Filter setting to Slow DC analog readings are not tracking voltage changes Reassign the analog Filter setting to Fast Upload Download of Setup Database fails Verify XMODEM protocol is being used Modem does not answer Check phone line connection Verify Modem Ring Count is not set to zero Modem answers but fails to connect Check modem Baud rate at host end Verify host modem is compatible with recorder modem Test host modem with another auto answer system Modem will not dial out alarms Test phone line for dial tone Perform Modem Test command Verify modem is enabled by Virtua
22. following message will be briefly displayed Use gt f to select items and then ENTER The Setup Menu of front panel accessible commands will then be displayed as shown below Clock CSvnc UName ENames INames DTimes Main Menu LCD Moving the highlight beyond the limits of the first menu will display the following additional commands Analog Virtual Speed PCode Modem Baud Diag RESET The Setup Menu consists of fourteen commands Table 4 provides a brief explanation of each command To select a command advance the highlight to the desired command and press the Enter key The use of each command is explained in the final sections of this chapter MicRO AIDE CWR 22xT USER MANUAL Name Description Clock Set date and time CSync UName Assign Clock Sync Input Create Unit Name ENames Create Event Name pairs INames Create Input Names and Identifiers Assign Event Name pairs DTimes Assign Detection Times Analog Configure Analog Inputs Virtual Speed Configure Virtual Inputs Configure Train Speed Monitor PCode Create Passcode Modem Assign Dial Numbers and Ring Count Baud Select Terminal Port Baud rate Diag Perform svstem diagnostics RESET Erase all Event Records Restore Setup Database to factorv default values Table 4 Front Panel Setup Commands Before proceeding the user should note that several of the commands req
23. installed but none is indicated a problem has occurred and must be corrected Keypad Test K Each of the twenty keys that comprise the front panel keypad can be checked by using the Keypad test The following instructions are displayed after selecting the command Keypad eest press HOG co cance A single unique character is displayed in response to pressing a key The correspondence between non numeric keys and displayed characters is listed in Table 5 below Key Browse Alpha Setup Esc Enter Decimal t 4 gt Displayed B A S E N P A v lt gt Table 5 Keypad Test Characters To exit the test press the Esc key located at the keyboard of the peripheral device that is commu nicating with the CWR 22xt Relay Test R The Relay Test allows the user to verify the operation of the internal relay and any alarm or indi cation circuitry connected to the contacts of the relay The following message will be displayed in response to selecting the Relay Test command To energize the relay select the On option To un energize the relay select the Off option Relay lest 1 Relay ON ERO OLE To exit the test press the ESC key The relay will automatically assume an un energized state Note The user may wish to contact MICRO AIDE customer setvice if a failure occurs as the result of any diagnostic testing Instructions on how to proceed will be offered Material Return and Limited Warranty policies are described on the in
24. is subjected to AC signals require the Slow setting to remove their ripple content DC signals can generally use either the Slow or Fast setting To toggle the existing setting simply press the Enter key All AC voltage and current measurements are reported in RMS units The Limit Values can be set separately They cannot exceed the bounds of the Range setting To change an existing setting highlight the value and press Enter Use the number keys to enter the new value Enter fractional and negative values by using the decimal and minus keys respectively After the new settings have been assigned press the ESC key to complete the command Virtual Virtual Inputs allow the CWR 22xt to identify and report a variety of signal conditions that may be of interest to the user Generally these conditions will refer to anomalies in the state of several relay circuits High or low analog levels may also be of special concern to the user The eight Virtual Inputs of the CWR 22xt are configured by use of the Virtual command Refer to the section entitled Virtual Inputs V on page 27 for additional information Data similar to the following will be displayed after selecting the Virtual command In the sample data cited above Virtual Input number 1 has not been assigned It retains its default settings The Virtual Input number is displayed in the upper left hand corner To select a different Virtual Input press the up or down arrow keys repeatedly
25. list describes the correct configuration e Transfer protocol Xmodem e Connection Typically Direct connect Com1 or Direct connect Com2 whichever is available at the PC Baud rate set to 38 400 and set to N 8 1 The boot loader can only communicate at 38 400 Baud Each of the steps required to perform the upgrade are listed below 1 Turn the power off and then back on to the recorder After a few seconds the following message will be displayed at the PC Micro Aide CWR 22 Flash Boot Loader Press ESC for boot loader 2 Press the Esc key at the keyboard of the PC within five seconds after the boot message is displayed The following menu of commands will then be displayed Menu U Upload new program to Flash memory D Display sample of uploaded code F Display flash R Run main program Enter Command 3 Press the U key followed by the Enter key to proceed with the upload A message similar to the following will be displayed Flash status is 0080 Flash memory mfg dev code is 0089 2274 For 28F200BVT 28F200B5T this should be 0089 2274 Hit enter to erase and start upload any other key to abort 4 Before the new firmware can be uploaded the contents of the Flash Memory chip must be erased To initiate the erase press the Enter key The following message will be displayed Start XMODEM upload now TECC CHAPTER 5 MAINTENANCE 5 The C characters listed in the last line of text are an indication that
26. page 46 for additional information regarding the use of this field Inputs The use of the Inputs field allows the user to review records from specific inputs The use of this field is described in Inputs on page 42 After the selection fields are assigned press the F1 function key to start the report The recorder will continue to print records as they occur in real time Press the ESC key to stop the report Live Status L The Live Status command provides a single screen snapshot of the present state of every recorder input i e Digital Analog and Virtual Inputs The state or measured value of each input will be continuously and automatically updated The Live Status report indicates the state of Analog and Virtual Inputs by their user assigned Input Identifier and Event Names Input Identifiers and Event Names are described in Input Names Identifiers on page 26 and Event Names E on page 25 respectively Note To properly view the Live Status report the PC must be configured to emulate an ANSI terminal An example of the Live Status report is shown below Live Status isgal 04 05 40 SAR AL Active AC Power 85Vac Fail xR 2 Idle Batteryl Ll 2Vde Normal GateDwnl Down AInput03 U OWde Ott GateDwn2 Up SpeedRec 27MPH Hi Speed Intel On bre 9 Gine baysal 3 OE Bojone Oers OFF put OFF Inputl0 Off besni lil exe aawe LAs WEE Loj Ss WEE Inputl4 Off Loj Ss WEE Input16 Off sensor i MO
27. page 72 MicRO AIDE CWR 22xT USER MANUAL Each CWR CS is shipped with a 15 cable Connect the cable from the CWR CS to the connector labeled Current Sensor located along the left end panel of the CWR 22xt Apply power to the recorder The recorder is now ready to report current measurements Caution Never connect a Current Sensor input to an Analog Input that has a voltage source connected Damage to the Current Sensor or improper operation of the voltage source may result CWR CS CWR Current Sensor MicRO AIDE Power o Analog Analog Analog Input 1 Input 2 Input 3 s O O Insert conductor through hole To CWR recorder Figure 8 CWR CS Front Top and Side Views APPENDIX D BILLS OF MATERIAL CWR 22xt Bill of Material M A Part No PA85 0059 00 PA85 0063 00 PA85 0083 00 HB2136 00 HC2402T6 01 I ACM2002 00 JRIDH14LP 00 JRIDS C14 00 JRIDS C16 00 JRSR 14K 00 JRSR 16K 00 JW147250 00 JW171633 00 JW171634 00 JW171638 00 JW171642 00 M 220178 00 M 220182 00 M 220211 00 M 220255 00 ZMCWR 22XT Description MFG Part No PCB ASSEMBLY PROCESSOR PCB ASSEMBLY KEYPAD PCB ASSEMBLY MODEM BUMPER HH SMITH 2 36 CABLE DB9 TO DB9 FEMALE TO FEMALE CABLE DEPOT 2402 T 6 FF MODIFIED LCD YELLOW GREEN 20 X 2 BACKLIT AMERICAN ZETTLER ACM2002D FL GBS CONNECTOR HEADER 14 PIN RIGHT ANGLE OUPIIN 3012 14GRB CONNECTOR AMP 746285
28. the terminal to the left and negative voltage on the right The voltage must be held for at least three seconds before proceeding 12 Use the same procedure described in the previous paragraph to test additional Digital Inputs 13 Perform a Query of the Event Records by pressing Q at the PC keyboard Select today s date and then press Enter Finally press the F1 function key Refer to the section entitled Query Events Q on page 38 for additional details 14 Verify that an Event Record is reported for each Digital Input tested Note any inputs not displayed and test the inputs again being careful to hold the voltage for at least three seconds A second Query should verify the retested inputs 15 Press the ESC key once to return to the Main Menu Press the L key The CWR 22xt will now display the real time status of Digital and Analog Inputs 16 Connect the 12 Vdc positive and negative test leads to the two inputs of Analog Input A1 17 Verify the Analog Input reading for Al is within 15 Vdc of the correct reading The correct polarity of the applied voltage should also be indicated 18 Repeat the previous two steps for the remaining three Analog Inputs MicRO AIDE CWR 22xT USER MANUAL Note 19 Before completing the Initial Check out Procedure verify the LCD is providing acceptable contrast If it needs to be improved adjust the potentiometer mounted on the internal printed circuit board Refer to the section entitl
29. use the arrow keys to scroll sequentially through each input the user can jump to a specific input by pressing the Browse key Select the input using the procedure described in Query by Input Number on page 54 Sample status data for each input type is listed below DOI GateDwnl Down LCD Input Status Digital Input AQ1 85Vac AC Power Fail LCD Input Status Analog Input MicRO AIDE CWR 22xT USER MANUAL V03 Pwr Fail Alarm On LCD Input Status Virtual Input The Input Number is listed at the start of the first row From left to right the Input Identifier and Event Name are listed in the second row The measured voltage current or train speed is listed at the end of the first row provided an Analog Input is selected The displayed data is continuously updated in real time Without the aid of a PC the user can check the sequence of events at a crossing ot while a control function is being exercised Press the ESC key to exit the Input Status feature and return to Idle Mode Flash The third option included with the Browse command allows the user to measure the flash rate of a circuit The following request for a Digital Input number will be displayed after selecting the Flash Rate option Input D01 The user must enter the number of the flashing input 1 18 Leading zeros are not required Press the Enter key to complete the entry Flash rate data similar to the following will be displayed Input D01 45 2 FPM On O
30. 1 CD nen contains the latest User Manuals ONO GUT Are UsER MANUAL Rail Signal Products Micno Alne EVENT RECORDERS SPEED MONITORS CURRENT SENSORS ISOLATED MODEMS BATTERY MONITORS VOLTAGE MONITORS LIGHT OUT DETECTORS CLOCK SYNCHRONIZE WHISTLE DETECTORS LOCAL CONTROL PANELS MicRO AIDE TA CWR 22XT EVENT RECORDER RECLOTAET SISO K ri Ba a lt gt Ki Xeremnat ayes ss go ile E et EE i Revised June 16 2009 MicRO AIDE CORPORATION Tel 626 915 5502 Fax 626 331 9484 E mail sales micro aide com 685 Arrow Grand Circle Covina CA 91722 Copyright 2002 by MICRO AIDE Corporation All rights reserved No part of this document may be reproduced or transmitted in any form or by any means without the written permission of MICRO AIDE Corporation The information in this document is subject to change without notice MICRO AIDE believes the information contained in this document to be accurate However MICRO AIDE assumes no responsibility for any errors or omissions Windows Windows98 Excel and Access are registered trademarks of Microsoft Corporation HyperTerminal is a registered trademark of Hilgraeve Inc Procomm is a registered trademark of Symantec Corporation lt lt lt OAJ TABLE OF CONTENTS CHAPTER 1 CHAPTER 2 GENERAL DESCRIPTION Introduction Key Features About this Manual INSTALLATION AND SETUP Introduction Unpacking Initial Check o
31. 472 5 5 2 RN6S10K 00 RESISTOR NETWORK 6 PIN SIP 10K 2 BI TECHNOLOGIES L061C103 al MicRO AIDE CWR 22xT USER MANUAL M A Part No SD4SPST 00 SH4352381 00 TFPC40RM8 00 U 74C923 00 U 75C185 00 U 80386EX 00 U ADC1251 00 U ADG408 00 U ADG419B 00 U DS1233 00 U DS1302 00 U REFO3GP 00 UF28F200B 00 UF29F016 01 ULOP27GP 00 ULOP490GP 00 UO4N33 00 UP18CV8 06 UR551001 01 USHC14 00 USHC165 00 USHCT245 00 X 32 768 01 XO1 8432 00 X050 0 00 Description MFG Part No SWITCH 4 POSITION DIP AMP 3 435640 5 SWITCH COVER 4 POSITION DIP GRAYHILL 76904 TRANSFORMER ASSEMBLY FLYBACK C KEYBOARD INTERFACE MOTOROLA MM74C923N C RS 232 TRANSCEIVER DIP TI SN75C185N C MICROPROCESSOR 25MHZ POFP NTEL KU80386EXTC 25 C A D CONVERTER 13 BIT DIP NATIONAL ADC1251CIJ IC MULTIPLEXER 8 TO 1 DIP SILICONIX DG408DJ IC ANALOG SWITCH DIP ANALOG DEVICES ADG419BN IC POWER RESET DALLAS SEMICONDUCTOR DS1233 10 IC CLOCK DIP DALLAS SEMICONDUCTOR DS1302 IC VOLTAGE REFERENCE DIP ANALOG DEVICES REFO3GP C FLASH MEMORY 60NS PSOP NTEL PA28F200B5 T60 C FLASH MEMORY 16MBIT SOP 85C AMD AM29F016B 90SI C OP AMP DIP ANALOG DEVICES OP27GP C OP AMP QUAD DIP ANALOG DEVICES OP490GP C OPTO COUPLER SINGLE DIP FAIRCHILD 4N33 PEEL 8
32. 5C DIP CT 18CV8PI 15 RAM 128K X 8 7ONS 85C DIP SAMSUNG K6T1008C2E DB70 IC CMOS INVERTER DIP TI SN74HC14N IC 8 BIT P S CONVERTER DIP MOTOROLA MM74HC165N IC CMOS OCTAL BUS XRCV DIP TI SN74HCT245N CRYSTAL 32 768KHZ 6PF EPSON C 002RX 32 768KHZE OSCILLATOR 1 8432MHZ DIP EPSON SG 8002DC 1 8432MPTMB OSCILLATOR 50MHZ DIP EPSON SG 8002DC 50 000MPTMB Qty 18 APPENDIX D BILLS OF MATERIAL PA85 0063 00 Keypad PCB M A Part No Description MFG Part No 3 3 Qty P 85 0063 00 PCB KEYPAD CWR 22XT 22X1 5 B x gt A x B al DHC 174 00 STANDOFF LED BIVAR DHC 174 z z 3 S 3 3 3 DL3962 00 LED GREEN SINGLE HP HLMP 3962 E i i P N N 3 JRIDH16LP 01 CONNECTOR 16 PIN RIGHT ANGLE OUPIIN 3012 16GRB x S 1 SP320 04 00 SWITCH PUSHBUTTON ESWITCH 320 04 El 1 GRY 5 N 20 PA85 0083 00 Modem PCB M A Part No Description MFG Part No A gt A A A A Qty P 85 0083 00 PCB MODEM ALL CWR EVENT RECORDERS R 5 B 5 5 5 i 5 1 C 3 3PF 00 CAPACITOR 3 3PF 50V NPO KEMET C052G339D2G5CA 5 A i k A A 7 1 C 10PF 01 CAPACITOR 10PF 10 2000V NPO MURATA DE0405SL100D2K i 5 B gt gt 2 C 22PF 01 CAPACITOR 22PF 5 50V NPO PANASONIC ECU S2A220JCA 5 5 5 5 5 5 5 al C 68PF 00 CAPACITOR 68PF 5 50V NP
33. AC current measurements The Range setting also selects the span of voltages or currents that will be monitored Lastly the Range setting selects the resolution that will be reported by the measure ment The 51 1 Vdc range is particularly useful in monitoring batteries that may exceed 24 Vdc when charging The 255 Vac range is useful for monitoring the AC power source connected to a battery charger The DC and AC current ranges are intended to be used with the CWR CS Current Sensor Each of the Ranges identified as AC utilize a true RMS method of measurement Consequently these settings can also be used when monitoring inputs with variable DC or pulse content Filter The Filter parameter can be set to either Fast or Slow The Fast setting utilizes a time constant of 1 seconds It is generally used when monitoring DC signals The Slow setting utilizes a time constant of 64 seconds It should be used when monitoring AC signals in order to smooth out their ripple content If the user is unconcerned about the Filter time constant it is best to use the Slow default setting Low and High Limits Analog Inputs are constantly compared to two Limit Values The Low and High Limit Values define regions of acceptable and unacceptable operation Outside the acceptable region the input is considered to be in an abnormal state An Event Record will be created when the Analog Input transitions into or out of either region Figure 4 on page 25 illustrates t
34. Analog Input is within its acceptable region of operation Event Names allow the user to distinguish Event Records from each other in a quick and unam biguous manner They should not be confused with Input Names and Input Identifiers see next section Event Names always occur in pairs The On Event and Off Event names form the pait They in turn distinguish the active and inactive Event Records respectively MicRO AIDE CWR 22xT USER MANUAL As many as eighteen Event Name pairs can be defined Once the pairs are defined they can be assigned to inputs of the CWR 22xt in any manner that helps the user distinguish Event Records precisely and quickly By way of example the Event Records for Digital Input 1 could be labeled XR_On and XR Off The Event Records for Analog Input A1 could be labeled Bat Norm and Bat Fail A typical response to the Event Name command is shown below In the interest of brevity only three of the eighteen pairs are listed The factory default Event Names are shown Event Names Number ON Name OFF Name To define a new Event Name simply position the highlight to the desired field and type the new name Event Names are restricted in length to eight characters They can be formed by any combination of letters numbers and syntax symbols Input Names Identifiers I The CWR 22xt utilizes two types of inputs The 18 Digital and four Analog Inputs are referred to as physical inputs because
35. E CWR 22xt Event Recorder This document refers to Version 1 12 of the CWR 22xt firmware Specifically the sample data and command details depicted were prepared using a Version 1 12 recorder Wherever possible step by step instructions have been included In the event the user has questions about any of the described procedures the user should contact MICRO AIDE for assistance Additional copies of this manual are available upon request MICRO AIDE CORPORATION 685 Arrow Grand Circle Covina CA 91722 Tel 626 915 5502 Fax 626 331 9484 E mail support micro aide com The MICRO AIDE Material Return and Limited Warranty policies can be found on the inside back cover of this manual MicRO AIDE CWR 22xT USER MANUAL User Notes nn INSTALLATION AND SETUP Introduction This chapter describes how to properly unpack install and set up the CWR 22xt prior to opera tion It is advisable to review the Unpacking Initial Check out and Installation sections before actually performing the procedures described in this chapter Unpacking Each CWR 22xt is packed in a shipping carton that is properly sized for the recorder Abundant packing materials are provided to minimize mechanical shock to the contents Before opening the carton inspect it for damage Damage to the carton should be noted Carefully remove the recorder It is advisable to save all packing materials in the event the recorder ever needs to be returned to MICRO AIDE Inspect t
36. ENames command Event ON OFF 01 FlashOn FlashOff A single Event Name pair is displayed at one time The number i e 1 to 18 of the pair is listed at the start of each row It is followed by the currently assigned active or On Event Name e g FlashOn and the existing inactive or Off Event Name e g FlashOff To create a new name of modify an existing name select the Event Name pair by pressing the up or down arrow keys to advance through the list of eighteen pairs Use the left and right arrow keys to select either the on ot off field Press the Enter key A blank field with a cursor in the left most position will be displayed Use the Alphanumeric Editing Procedure on page 58 to create a new name Use the same procedure to modify additional names INames The INames command is a multi purpose command that allows the user to assign Input Identi fiers Input Names and Event Name paits to each input of the recorder Input Identifiers and Input Names allow the user to interpret Event Records more precisely by referring to inputs with labels that are unambiguous e g Track Switch Control vs Digital Input 18 Refer to the section entitled Input Names Identifiers I on page 26 for additional details Data similar to the following will be displayed after selecting the Names command DOI Id Name Event DInput0l The Input Number is always displayed in the upper left hand corner To select a different input press the up or do
37. Esc key will not complete the command if the user is in the process of editing a field Pressing the ESC key prior to accepting the new value will instead restore the highlighted field to its previous value To complete a command that requires pressing the ESC key first accept the contents of the last Edit Field by pressing the Enter key or moving the highlight to another field Some commands are completed by responding to a choice listed in a Selection Field e g No or Yes In these cases the command is completed by highlighting the desired choice and then pressing the Enter key Pressing the ESC key is the equivalent of selecting the default choice generally the No option As a rule of thumb executing the No option will abandon any field changes made prior to the completion Other commands are completed by pressing the key described in a prompt message displayed with the command Prompts are frequently listed with commands as an aid to the user After the command is completed the user will be returned to the menu that was previously displayed Data Flow Control Several of the setup and operational commands can generate considerable amounts of displayed data If the user wishes to observe this data on the screen of a PC it may be helpful to temporarily pause the data stream being sent by the recorder The Pause and Resume commands may be used to provide the required data flow control To Pause the data being sent press the Ctrl and S keys si
38. K 01 562K 00 576K 00 825K 01 1M 02 R R R R R R R R R R R R R R R R R R R R 6 8M 00 RVERZV07D 00 T 82127R 00 U SMARTDA 00 U SMARTSC 00 UMAT24C02 01 X028 224 00 Description MFG Part No VOLTAGE REGULATOR 3 3V BURR BROWN REG1117 3 3 RESISTOR 10 OHM 5 1 8W RESISTOR 24 OHM 5 1 2W RESISTOR 100 OHM 5 1 8W RESISTOR 150 OHM 5 1 8W RESISTOR 1K 5 1 8W RESISTOR 10K 5 1 8W RESISTOR 33 2K 1 1 8W RESISTOR 47K 5 1 8W RESISTOR 51K 5 1 8W RESISTOR 100K ce 1 8W RESISTOR 143K ce 1 8W 1 8W 8W ole RESISTOR 332 AN o RESISTOR 348 8W A o RESISTOR 475K 1 1 8W 1 8W 1 8W 1 8W 1M 5 1 8W RESISTOR 562K ce RESISTOR 576K ce RESISTO ole 825K RESISTO RESISTOR 6 8M 5 1 8W VARISTO PANASON 175V 1200A R R R R R R R R R R RESISTOR 270K 5 R R R R R R R R R IC ERZV07D24 TRANSFORMER MIDCOM 82127R C MODEM DAA CONEXANT SMARTDAA WWDEVTF C MODEM CONEXANT SMARTSCM 33DEVTF C EEPROM SERIAL 2 7V 85C ATMEL AT24C02A 10P1 2 7 OSCILLATOR 28 224MHZ 3 3V EPSON SG 8002DC 28 224MPCMB CWR CS Bill of Material M A Part No PA85 0038 00 H 8477 00 HC2402T15 00 M 220183 00 M 220183 01 M 220183 02 Description MFG Part No PCB ASSEMBLY QUAD CURRENT SENSOR G
39. M APACITOR 220MF 16V RADIAL ELECTROLYTIC LNA RJ3 16V221MBX APACITOR 2200MF 6 3V RADIAL ELECTROLYTIC LNA RJ3 6V222MBX Cc E C E CAPACITOR 4 7MF 25V RADIAL TANTALUM CAPACITOR 10MF 16V TANTALUM CAPACITOR 33MF 16V RADIAL TANTALUM DE 400V 004 o 4 ODE 5 o 9 822 DE 14 DIODE SCHOTTKY 60V MOTOROLA MBR160 ZENER DIODE 24V 5W 1N5359B FUSE AMP LITTELFUSE 225001 FUSE CLIP LITTELFUSE 111501 TEST POINT COMPONENTS CORP TP 101 10 JACK PHONE RJ 11 RIGHT ANGLE AMP 520250 2 CONNECTOR FEMALE DB9 RIGHT ANGLE FCI ID09S33E4GV00 CONNECTOR MALE DB9 RIGHT ANGLE ADAM TECH DEO9PL23 WIREWRAP PINS 36 BY 1 SAMTEC TSW13607LS SOCKET IC 20 PIN OUPIIN 8003 20T3 SOCKET IC 32 PIN OUPIIN 8003 32T6 CONNECTOR HEADER 10 PIN STRAIGHT ANGLE OUPIIN 3012 10GSB Qty 19 APPENDIX D BILLS OF MATERIAL M A Part No Description MFG Part No A A A P Qty JRIDH14LP 01 CONNECTOR HEADER 14 PIN STRAIGHT ANGLE OUPIIN 3012 14GSB A A A 3 r 5 A P al JRIDH16LP 01 CONNECTOR HEADER 16 PIN STRAIGHT ANGLE OUPIIN 3012 16GSB i B B 5 5 r 5 2 JW151316 00 CONNECTOR MALE 7 POSITION RIGHT ANGLE WEIDMULLER 151316 B B B B 5 5 5 x 1 JW151326 00 CONNECTOR MALE 8 POSITION RIGHT ANGLE WEIDMULLER 151326 B 3
40. Name is listed as the Event Name x lower case The Digital or Virtual Input remains in its On state The referenced input is not the source of the Event Record colon The Digital or Virtual Input has transitioned into its Off state The referenced input is the source of the Event Record The assigned Off Event Name is listed as the Event Name period The Digital or Virtual Input remains in its Off state The referenced input is not the source of the Event Record The four symbols used to indicate the state of an Analog Input are described below asterisk The Analog Input has transitioned into its unacceptable region of operation The referenced input is the source of the Event Record The assigned On Event Name is listed as the Event Name exclamation mark The Analog Input remains in its unacceptable region of operation The referenced input is not the source of the Event Record equals sign The Analog Input has transitioned into its acceptable region of operation The referenced input is the source of the Event Record The assigned Off Event Name is listed as the Event Name CHAPTER 3 OPERATION blank The Analog Input remains in its acceptable region of operation The referenced input is not the source of the Event Record Event Names and Limit Values are described in Event Names E on page 25 and Low and High Limits on page 24 respectively This concludes the chapter on how to
41. O PANASONIC ECU S2A680JCA 5 z 2 C 100PF 00 CAPACITOR 100PF 5 100V CERAMIC NPO PANASONIC ECU S2A101JCA 5 i i 2 C 150PF 00 CAPACITOR 150PF 103 100V NPO PANASONIC ECU S2A151JCA z z gt A 1 C 220PF 01 CAPACITOR 220PF 1KV CERAMIC NIC NCD221K1KVY5F 5 3 3 3 3 3 3 3 1 C 001MF 00 CAPACITOR 001MF 50V CERAMIC i i N 5 C 001MF 03 CAPACITOR 001MF 2KV CERAMIC MALLORY HS102M B B B B 5 R 2 01MF 00 CAPACITOR O1MF 50V CERAMIC 5 B R B p Z l C 033MF 00 CAPACITOR 033MF 10 100V CERAMIC PANASONIC ECU S2A333KBA N 5 3 i i 3 3 i 3 2 C 047MF 01 CAPACITOR 047MF 10 100V CERAMIC PANASONIC ECU S2A473KBA 3 5 A 5 3 2 C 1MF 00 CAPACITOR 1MF 50V CERAMIC A 5 z z P P z 13 CT10MF 00 CAPACITOR 10MF 16V TANTALUM 7 3 3 3 5 D BAT43 00 DIODE SCHOTTKY 30V 100MA DIODES INC BAT43 D DB105 00 DIODE BRIDGE 600V 8A MICRO SEMI DB105 DZIN753A 00 DIODE ZENER 6 2V 500MW JFBCS 108 00 CONNECTOR HEADER FEMALE 16 PIN SAMTEC BCS 108 L D TE Q MJD50 00 TRANSISTOR 400V 2W ST MICRO MJD50 Q MPSA44 00 TRANSISTOR 400V 350MW ON SEMI MPSA44 B A A 5 5 5 5 5 gt 5 2 MicRO AIDE CWR 22xT USER MANUAL M A Part No QRI117 3 00 OOHM 02 240HM 00 1000HM 02 1500HM 01 1K 01 OK 01 33 2K 00 47K 01 51K 00 100K 03 143K 01 270K 00 332K 00 348K 00 475
42. ROMMET 75 I D KEYSTONE 8477 CABLE DB9 TO DB9 MALE TO MALE CABLE DEPOT 2402 T 15 MM SHEETMETAL COVER SHEETMETAL BASE SHEETMETAL FRONT PANEL Qty Qty PoP PP M A Part No M 220183 03 M 220183 04 M 220184 04 ZMCWR CS APPENDIX D BILLS OF MATERIAL Description MFG Part No SHEETMETAL REAR PANEL SHEETMETAL SIDE PANEL RIGHT SHEETMETAL SIDE PANEL LEFT REFERENCE NOTE PART OF CWR 22XT USER MANUAL CWR CS Subassemblies PA85 0038 00 Quad Current Sensor PCB M A Part No P 85 0038 00 C 220PF 00 C 1MF 00 CT33MF 00 DL3962 00 H PTX2515 00 H TP 101 00 JFDB09S 00 Q A3516 00 QR7805 00 3300HM 00 1 8K 00 2 7K 00 4 99K 00 7 87K 00 8 87K 00 A e e N We AA A 73 2K 00 RP1K 00 ULOP490GP 00 Description MFG Part No PCB QUAD CURRENT SENSOR CAPACITOR 220PF 5 100V CERAMIC AVX SR211A221JAA CAPACITOR 1MF 50V CERAMIC CAPACITOR 33MF 16V RADIAL TANTALUM LED GREEN HP HLMP 3962 TOROID 062 GAP EASTERN COMPONENTS P TX251510 3C81 G 062 TEST POINT COMPONENTS CORP TP 101 10 CONNECTOR FEMALE DB9 RIGHT ANGLE FCI IDO9S33E4GVOO TRANSISTOR HALL EFFECT ALLEGRO A3516EAU VOLTAGE REGULATOR 5 V NATIONAL LM340T 5 RESISTOR 330 OHM 5 25W RESISTOR 1 8K 5 25W RESISTOR 2 7K 5 25W RESISTOR 4 99K 1 25W RESISTOR 7 87K 1 25W RESISTOR 8 87K 1 de 25W ce RESISTOR 73 2K 15 25W POTENTIOMETER 1K
43. Report Type field can be set to Dump default setting Browse or Comma The proper selec tion depends upon the user s requirement Each option is described in the following sections Dump The Dump option will issue Event Records in a continuous stream The streaming of records will only cease when the last record is issued or the user executes a Pause or Abort command Refer to the section entitled Data Flow Control on page 15 Generally the Dump option is used if a large number of records are to be inspected The Dump option is generally used if Event Records need to be captured to a PC file Browse The Browse option allows the user to inspect a set of records one screen at a time It will typically display eleven one line records or seven two line records per screen The same set of records will be displayed indefinitely until the user presses an arrow key to review additional records The Browse option is most useful when a limited number of records in a narrow time frame need to be reviewed A completely new screen of records can be displayed by pressing the up and down arrow keys A single new record can be displayed by pressing the left and right arrow keys The last line of text in each screen explains the use of the arrow keys Comma The Comma option formats the Event Record data so that it can be easily imported to a spread sheet or database application such as Excel or Access respectively This option takes the var
44. Upload Setup Data command The following message will be displayed CHAPTER 2 INSTALLATION AND SETUP Are vou SURE vou want to upload new Setup Data from PC to CWR2 No Yes Select No to abort the upload Select Yes to proceed If the user elects to proceed with the upload the following message will be displayed Receiving Setup Data via XMODEM Ctrl X to stop beeee The sequence of C characters indicates the recorder is awaiting the Xmodem file The steps necessary to complete the upload depend upon which communications application is being used The following paragraphs describe the HyperTerminal and Procomm Plus methods respectively Windows 98 was used in the following procedures Later versions of these programs may be slightly different However the fundamental approach will remain valid HyperTerminal 1 With the mouse click on the Transfers command then the Send File command The Send File dialog box will open Verify that the Xmodem protocol is selected N Select the correct disk drive folder and filename e g setup 10 bin If the various settings are correct click the Send button Go An information box will automatically open It will indicate the progress of the transfer After a few seconds depending upon the Baud rate the information box will close automatically to indicate a successful transfer Procomm Plus 1 With the mouse click once on the Send File icon near the top center of the Proco
45. aid to the user Event Detection Times can be set to a thousandth of a second 001 seconds to capture fast electronically generated control signals Events satisfying the Detection Time criteria are date and time stamped to the nearest thou sandth of a second The real time clock used by the recorder can be synchronized to an external signal Flashing signal events are detected The flashing rate of a circuit can be precisely measured and reported CHAPTER 1 GENERAL DESCRIPTION Fight Virtual Inputs can be programmed to create Event Records that identify alarm or fault conditions of special interest to the user e Installation is quite simple Input wires are terminated in detachable screw down terminals Wire sizes as large as 12 AWG can be used Power consumption is typically less than AW A 10 to 36 Vdc power source can be used to power the recorder The user interface provides full cursor control when using a PC Three distinct levels of password security provide protection against unauthorized access Several diagnostic commands can be executed to verify important system operations e Firmware updates can be downloaded to the recorder directly from the MICRO AIDE factory when the CWR 22xt is equipped with the optional internal modem About this Manual Note This document is intended to provide the user with comprehensive easy to read instructions on how to install set up operate and maintain the MICRO AID
46. al and Virtual Input at the moment the event was detected Digital Inputs D1 through D10 are depicted by the first ten characters Digital Inputs D11 through D18 are depicted by the next eight characters Finally The Virtual Inputs are indi cated by the last eight characters A period and upper and lower case x characters are used as symbols to indicate various states Refer to the section entitled Symbol Legend on page 48 The measured value of each Analog Input is also reported The unit of measurement is listed to the right of the numerical value Negative values are preceded by a minus sign Special symbol characters are used to describe the measurement relative to its assigned Limit Value There are MicRO AIDE CWR 22xT USER MANUAL four symbols used for this purpose They are described in the section entitled Symbol Legend on page 48 The symbols are listed to the immediate right of the units specifier A unique feature of the CWR 22xt is its ability to report a complete set of analog measurements within each Event Record This allows the user to determine if variations in the analog measure ments ate occurring as the result of specific signal conditions Symbol Legend The four symbols used to indicate the state of Digital and Virtual Inputs are described below X upper case The Digital or Virtual Input has transitioned into its On state The referenced input is the source of the Event Record The assigned On Event
47. alog Inputs ate wired somewhat differently than Digital Inputs The four Analog Inputs termi nate in a separate connector along the left end panel of the recorder They are labeled as inputs AT through A4 The connector that is used is detachable and also uses a screw down terminal method for anchoring each wire Event Records will indicate positive and negative polarities for each Analog Input The user may wish to verify the proper operation of each input The Initial Check out Proce dure on page 5 should be used to identify any faulty input wiring Jumper Combs As an aid to the installer each CWR 22xt is provided with several Jumper Combs Weidmuller part number 147250 Each Jumper Comb allows ten adjacent screw down terminals to be connected together Unwanted points may be removed by cutting them or bending them away from the detachable connector CWR CS Current Sensor The optional CWR CS Current Sensor is an accessory that can be used to monitor DC and AC current flow through various lamp and control circuits It is designed to provide a completely passive non intrusive method of measuring current As many as four circuits are monitored by the CWR CS The CWR CS utilizes Analog Inputs A1 through A4 of the recorder Among these inputs any combination of voltage and current inputs not exceeding four total is permitted If an Analog Input is to be used to monitor a current signal the voltage source to that input must b
48. and code contained within parenthesis Query Events Q The Query Events command provides the principal means by which Event Records are inspected It allows the user to inspect events for a particular time frame and or specific set of inputs Additionally the Query Events command includes several data output options that can be selectively employed depending upon the user s data display requirements A typical response to the Query Events command is shown below Note CHAPTER 3 OPERATION Select Range of Dates Os 504 07 02504 0302 ooo ebe Ok 04 2 02 ll sz Wil oz eis o gt we l eoz 01 02 M4302 OWA 19 02 W 2002 o alyz MA AA G2 Gez Ge 0204 26 02 Gez er O 202 WE Mel 0 YE S02 Use arrow keys to move Space start selection Enter accept ESC cancel The data array forms a table of dates in MM DD YY format The table indicates that at least one Event Record was logged in memory for each day listed Days where no records were logged will not be included in the table e g 05 02 02 in the above The CWR 22xt can store Event Records for 128 different dates provided the event storage capacity is not exceeded The CWR 22xt utilizes a rotating memory Records from the 129th day will automatically over write records from the first day regardless of how many records are stored in memory The first step in using the Query Events command is to select the date or range of dates that the user wishes to inspect To select a single dat
49. at any time to restore the recorder to its factory default settings The command can also be used to clear previously logged Event Records This step is listed as part of the Setup Procedure since it can be useful in restoring the recorder to a known CHAPTER 2 INSTALLATION AND SETUP state consistent with this documentation Additionallv anv programming or Event Recotds created as a part of the Initial Check out Procedure will be erased Note The time and date settings are not affected by the Reset System command The following menu will be displayed after executing the Reset System command Reset System SsResetisetup Data E Reset Event Memory B RESOR BOER Each command is described in the sections that follow Reset Setup Data S The CWR 22xt utilizes two non volatile memories The first is referred to as the Setup Database The Setup Database contains all of the programmed parameters established by the user These parameters can be restored to their factory default values by executing the Reset Setup Data command Table 1 lists the default values for each of the programmable parameters Parameter Default Value Unit Name NOT SET Terminal Port Baud Rate 38 400 Administrative Password PASSWORD Restricted Password LOOKWORD Passcode 12345678 Ring Count 2 Primary Dial Number none assigned Secondary Dial Number none assigned Clock Sync Input None ass
50. ate in screw down connectors that are detach able The cable installation can be performed mote easily if the female connectors are first detached from their male halves that remain secured to the CWR 22xt circuit board Alarm Relay 1 Wire the alarm indicating device or circuit to the appropriate relay terminals labeled C NO or NC Le common normally open normally closed respectively MicRO AIDE CWR 22xT USER MANUAL Note Peripherals 1 Attach the peripheral cable to the DE 9 male connector labeled Terminal 2 Connect the optional telephone line to the RJ 11 connector labeled Line Input Circuits Events will only be recorded if the input circuits are wired properly to the CWR 22xt The correct polarity of Digital and Analog Inputs must be identified Digital Input circuits are typically wired to twelve position detachable connectors Individual pairs are wired horizontally to adjacent terminals The positive lead of the digital circuit to be monitored must be connected to the left side terminal labeled The common or return lead of the digital circuit must be connected to the right side terminal labeled Positive and negative voltages can be monitored by a Digital Input even if they occur from the same circuit In such cases the circuit is wired to two inputs of the recorder one for each polarity Figure 1 on page 6 illustrates how to connect negative voltage circuits An
51. ation in the result is an indication of a problem A typical response to the Checksum Test Program Memory command is listed below Program Memory Checksum 2600 Test Complete Press any key to continue The checksum takes only a few seconds to be calculated The checksum value labeled 2600 in the above example will vary with the version of the firmware installed in the recorder Flash Memory Test F The Flash Memory Test is performed on the memory chip used to store Event Records The test verifies that the microprocessor can access the Event Record memory A typical response to the Flash Memory Test command is listed below Flash Memoryl 2048K Test Complete Press anv kev to continue The teference to 2048K indicates that the recorder has a capacitv of 190 304 Event Recotds A value of OK indicates a failure has been detected Modem Test M The Modem Test can be performed at any time to verify that the microprocessor can communi cate properly with the internal modem The test can be performed while the modem is idle or while a call is active The test results will indicate the maximum line speed of the modem The two possible responses to the Modem Test command are listed below Modem Test in progress Modem found 33600 Test Complete Press any key to continue MicRO AIDE CWR 22xT USER MANUAL Modem Test in progress Modem found NONE Test Complete Press any key to continue If a modem is
52. automatically restored Event Record Formats Event Records provide the user with information about the status of each input at a specified moment in time Event Records consist of printable ASCII characters Two different formatting methods are employed by the CWR 22xt They create one and two line records Both formatting options are available in the Query Events and View Events commands In the sections that follow both formatting options are described in order of increasing detail No Details The one line form is used to provide event information from a single input Analog Input levels are not listed in this format Two sample records are shown below 14 57 54 699 04 06 NS Gate Down Relay GateDwnl Down D03 14 58 03 335 04 06 AC Power 120V AC Power Fail A L Each record consists of six data elements Each of these is described below from left to right Time The time the event was detected is indicated in military style HH MM SS format The time is identified to the nearest thousandth of a second e Date The date the event was detected is indicated in MM DD format CHAPTER 3 OPERATION Input Name The twenty character Input Name identifies the input The names NS_Gate_Down_Relay and AC_Power_120V are listed in the sample records Input Identifier The eight character Input Identifier further identifies the input The identi fiers GateDwnl and AC Power ate listed in the sample records e Event Name The Even
53. biee s DIOL Fl to measure ESC to quit The user must enter a valid Digital Input number in the Input to Measure field The entry must take the form Dnn where nn must be in the range from 1 to 18 Leading zeros are not required Press the Enter key to accept the Input Number Finally press the F1 function key to initiate the measuring process A data screen similar to the following will be displayed MicRO AIDE CWR 22xT USER MANUAL Measure Flash Rate Input to Measure DOI MEISE son ESIC ira Gjbalie Flashes Minute 45 2 On Time 664 Sec Off Time 664 Sec Cycle Time 328 Sec Detect Time 664 Sec The lower five lines of text reflect the Measure Flash Rate data The first line indicates the number of flashes per minute e g 45 2 The second and third lines report the On Time and Off Time durations respectively The data listed in the fourth line referred to as Cycle Time is the duration of one on off sequence It is the sum of the On Time and Off Time durations Finally the fifth line specifies the optimum Detection Time to be assigned to inputs using the reported flash rate The data listed in the Measure Flash Rate report is updated continuously and automatically For typical flash rates the data will be updated every several seconds To stop the measuring process simply press the Esc key The Digital Input can then be connected to another circuit The original Detection Time and Clock Sync settings will be
54. bles i e inputs Each state is identified by its user defined Event Name The states for the variable labeled POK Rly are POK Up and POK Dwn The sample data includes three variables so eight lines of text lists all of the possible variable states The last column of data in each line includes a selection field The field can be set line by line to an active or inactive state The user decides which state to assign to the Virtual Input for each combination of variable states For the sample data shown the Virtual Input is assigned to its active state labeled Alrm On when the variable s states are POK Dwn Lite Off and Bat Bad Anytime this combination of states is found to exist among inputs D18 D7 and A8 respectively an active Event Record for Virtual Input V3 will be created and stored in memory An additional inactive Event Record will be created when the variable states no longer satisfy these requitements Perform the following steps to complete the Virtual Input programming procedure 1 Move the highlight to the first line of text that lists the input states 2 Press the Spacebar to select the correct Event Name for that combination of input states MicRO AIDE CWR 22xT USER MANUAL Note 3 Move the highlight to the next line and repeat the preceding step 4 When the Virtual Input state is correctly defined for each line press the ESC key and return to the variable assignment table 5 Press th
55. d Model CWR 22xt Event Recorder Ver 1 12 C 2002 MICRO AIDE INC KKKKK NOT SET KKKKK Event storage capacity 190304 Enter password Password Request CHAPTER 2 INSTALLATION AND SETUP 8 If the recorder fails to display the password request check the power and peripheral connec tions and Baud rate and communications settings If the problem can be isolated to the CWR 22xt contact MICRO AIDE customer service for instructions on how to proceed Note Repair and return policies are described on the inside back cover of this manual 9 The remainder of the Initial Check out Procedure presumes the recorder is configured to operate with the factory default settings and Event Records have not been logged into memory If this is not the case the user may wish to reset the recorder Refer to the section entitled Reset System R on page 16 for details 10 From the PC s keyboard type PASSWORD in upper case letters This is the default pass word Complete the entry by pressing the Enter key The Main Menu shown below will be displayed MICRO AIDE CWR 22xt Event Recorder Setup Live Status Query Events View Events Measure Flash Rate Transfer Files Diagnostics Log Off S L Q V M T D X Main Menu 11 Using a short pair of stripped jumper wires place 12 Vdc and negative to Digital Input number 1 Refer to the silkscreened labels located near the input terminals Positive voltage should be placed on
56. d Monitor enter a zero value in any of the four fields Distance between Sensors The distance between each sensor must be known in order to calculate the speed of each truck The value must be in the range from 36 to 99 or 8 to 5280 The value must be entered as a whole number To the right of the distance field is the units selection field Press the Spacebar to toggle the setting between inches and feet Tip Greater values of distance e g 500 instead of 50 will result in improved speed accuracy MicRO AIDE CWR 22xT USER MANUAL Excessive Speed Limit The Excessive Speed Limit value establishes a setting which if exceeded will result in an Event Record being created The limit must be entered as a whole number in miles per hour It must be in the range from 5 to 99mph distance in inches or 5 to 180 mph distance in feet A train found to be in motion at a rate greater than the Excessive Speed Limit will have its speed reported as an Analog Input A4 value Accordingly Analog Input A4 is subject to the following treatment e All voltage and current measurements will be ignored The user will not be able to alter the Analog Configuration settings for Analog Input A4 To regain control of these settings the Train Speed Monitor must first be disabled Print Setup Data P The Print Setup Data command can be used to display the setup parameters assigned by the user The following menu of sub commands is displayed after se
57. e Esc key to exit the command or reposition the highlight and select the next Virtual Input Repeat both of the previously described procedures as required Measure Speed M The CWR 22xt includes a speed measuring feature that can be used to continuously monitor train speed and log speed violations The use of this feature is strictly optional It is referred to as the Train Speed Monitor feature and it is controlled by the Measure Speed command The recorder must be properly configured before the Train Speed Monitor can be used Regard less of other variations in the configuration the following list of requirements must be satisfied Two train sensors must be wired to two spare Digital Inputs of the recorder e Each train sensor must reliably indicate the nearby presence of a train The sensor outputs must be either open no train or closed to positive battery nearby train e The distance between each sensor must be in the range from 36 to 99 or 8 to 5280 e Analog Input A4 will be used by the Train Speed Monitor to report train speed An array of five fields similar to the following will be displayed after selecting the command Measure Speed Parameters First Sensor Input Soo Second Sensor Input ae Distance Between Sensors 0 inches Excessive Speed Limit 0 MPH To disable measure speed feature set sensor inputs s to none or distance or speed limit to zero The use of each field is described in the foll
58. e discon nected The disconnection is required to prevent a conflict between the voltage input and current signal from the CWR CS The proper procedure for assigning an Analog Input to the CWR CS Caution CHAPTER 2 INSTALLATION AND SETUP involves changing one to four switch settings on the CWR 22xt printed circuit board Refer to the section entitled Analog Input Switches SW1 on page 72 for additional details Never attach the CWR CS to the CWR 22xt without first disconnecting the Analog Inputs This will prevent placing an interfering signal on the analog circuit that is attached to the CWR 22xt Applying Power Once the cabling is installed the power can be applied Shortly after power is applied the PC will display the password request Refer to the sample data labeled Password Request on page 8 After the initialization sequence is completed the front panel LCD will indicate the time and date This completes the CWR 22xt Installation Procedure The Setup Procedure can now be started Setup Procedure Note Before the CWR 22xt is ready for use the recorder must be configured to reflect the operation required by the user The following steps should be performed in the sequence listed It is assumed that the user is accessing the CWR 22xt via a PC Succeeding chapters describe how to use the front panel display and keypad as well as access the recorder via the optional internal modem It is further assumed that the user ha
59. e range from 0 to 99 Accept the new value by pressing the Enter key A setting of zero will prevent the modem from answering incoming calls To assign a Primary or Secondary Dial Number move the highlight to the fields labeled Prim ot Sec respectively The existing assignment will be highlighted Press the Enter key A blank field with the cursor in the left most position will be displayed Enter a valid dial number by pressing the appropriate number keys The Alphanumeric Editing Procedure on page 58 can be used to insert non numeric characters such as a comma to insert a two second pause Press the Enter key to accept the new assignment Complete the command by pressing the ESC key CHAPTER 4 DISPLAY AND KEYPAD Baud The Baud command allows the user to assign a Baud rate to the Terminal Port It is likely the following data will be displayed after the Baud command is selected 19200 38400 57600 115200 The 38400 setting may be highlighted It is the default setting used by the recorder If the up or down arrows keys are pressed the following additional settings will be displayed 300 600 1200 2400 4800 9600 To assign a new Baud rate move the highlight to the desired setting by pressing the arrow keys Press the Enter key to accept the new selection The Baud rate of the peripheral device attached to the Terminal Port must be changed to match the new setting Diag The Diag command is used to test four critical record
60. e simply position the highlight to the desired date and press the Enter key To select a range of dates follow the steps listed below 1 Using the appropriate arrow keys highlight the first date in the range 2 Press the Spacebar to anchor one end of the range to be highlighted 3 Press the appropriate arrow keys until each date in the desired range is highlighted 4 Press the Enter key to accept the highlighted range of dates The Esc key can be pressed at any time to cancel the selection The user will then be returned to the Main Menu If however the selection is accepted an array of Selection and Edit Fields enti tled Query Report will be displayed A sample Query Report is shown below MicRO AIDE CWR 22xT USER MANUAL Query Report Start Date 04 06 02 Start Time 00 00 00 End Date 04 06 02 End Time de Include Details Yes Reverse order No Report Type Inputs blank all Fl Execute Report ESC cancel The Event Recotds of interest to the uset can be further qualified bv the six fields listed in the Query Report The use of each field is described in the sections that follow Start Time Event Records that are time stamped aftet the assigned Start Time for the dav selected as the Start Date will be issued bv the Querv Command The Start Time can be assigned anv value from 00 00 00 to 23 59 59 The default setting is alwavs 00 00 00 The Start Time must be entered in militarv format End Time
61. ed Use gt N to scroll Browse to select inp Provided the Browse key has not been pressed the first Event Record meeting the specified date and time criteria will be displayed Refer to Event Record Format on page 52 The left and right arrow keys can be used to review Event Records in forward or reverse chronological order Holding down an arrow key allows the user to search through the record set very quickly The limits of the record set will be indicated by a message stating either Start of Data or End of Data To exit Browse Mode and return to Idle Mode press the Esc key Press the Browse key any time after the start time is specified to inspect records for a particular input This procedure is referred to as Query by Input Number Query by Input Number To inspect Event Records for a specific input press the Browse key after the starting time is specified The following message will be displayed Input to query selects all A flashing highlight will be positioned in the Input Number field located in the first row of text To specify an input follow the steps listed below Note CHAPTER 4 DISPLAV AND KEVPAD 1 Press the Alpha key repeatedly until the desired input type i e D A V or S is displayed 2 Press the appropriate number keys to enter the Input Number Leading zeros are not required 3 Press the Enter key to display the first Event Record satisfying the date time and Input Numbe
62. ed Adjusting the LCD Contrast on page 72 This concludes the Initial Check out Procedure This procedure may be used at any time to verify that the CWR 22xt is operating properly Power can now be removed from the recorder Connec tions to the PC should also be removed In the event that a failure occurs during any part of this procedure a series of diagnostic tests should be performed Refer to the section entitled Diagnostic Testing on page 74 Alternatively the user may wish to contact MICRO AIDE customer service Instructions on how to proceed will be offered Material Return and Limited Warranty policies are described on the inside back cover of this manual Installation Procedure The following sections describe the recommended Installation Procedure Figure 1 on page 6 and Figure 2 on page 7 illustrate elements that are common to most installations The illustrations also depict the location of each connector used in the installation Location The location where the CWR 22xt is to be installed should comply with a few simple require ments The ambient temperature near the recorder should be in the range from 40 C to 72 C Mounting Note The CWR 22xt can be mounted on top of a suitable shelf or secured to a back board Each recorder is equipped with non slip rubber feet Precautions should however be taken to prevent the recorder from dropping off the edge of the shelf or desktop The shelf mounting brackets prov
63. entering a correct password All sessions should be terminated by executing the Log Off command To log off of the recorder press the X key The following message will be displayed About to Log Off are you sure NORMES If the user proceeds with the log off the current session will be immediately terminated This completes the Setup Procedure for the CWR 22xt Event Recorder The recorder is now prepared to log events in accordance with the setup performed by the user Since the installation and setup of the recorder are critical to how the CWR 22xt will perform it is advisable to review the steps taken earlier The next chapter describes how to operate the CWR 22xt hh SEN OPERATION Introduction This chapter describes how to operate the CWR 22xt from either a keyboard equipped printer or PC running a suitable communications program Local i e on site as well as remote methods of operating the Event Recorder are described Before the recorder can be operated it must be prop erly installed and set up A PC or printer must be online with the recorder The use of the LCD panel and keypad are described in the next chapter Multi User Operation A unique feature of all MICRO AIDE recorders is their ability to handle simultaneous operation from multiple users via the modem Terminal Port or front panel keypad This multi user capa bility eliminates the annoying practice in some recorders of one user effectively locking out a sec
64. er elements They include the program memory Event Record memory optional modem and internal relay Each test can be performed at any time and is completely non destructive The contents of the Setup Database and Event Record memories will remain unmodified The following data will be displayed after selecting the Diag command Test Item Checksum Flash Modem Relay The highlight will initially be positioned over the Checksum field To select a different test posi tion the highlight in the desired field Press the Enter key to perform the test Each test is described in the sections that follow Checksum A checksum will be calculated and displayed after a few seconds The results of a typical Checksum test are listed below Checksum 2600 Hit any key Note The reported checksum value will vary depending upon the version of the installed firmware MicRO AIDE CWR 22xT USER MANUAL Flash The results of a typical Flash test are listed below Flash Memorv 2048K Hit any key The Flash test verifies that the microprocessor can properly access the Event Record memory The reference to 2048K indicates the size in bytes of the memory device A value of OK indicates a failure has been detected Modem Hither of two results can be expected from the Modem test The following response verifies that a modem is installed and that the microprocessor is able to communicate with the modem A typical test takes a few seconds for the microp
65. er listed Correc tive actions to be performed inside the CWR 22xt must be carried out in accordance with the procedure entitled Working Inside the Recorder on page 71 If the user is unable to resolve the problem MICRO AIDE customer service technicians should be contacted The user will be asked to state the problem related symptoms and indicate any operations or conditions that have a bearing on the problem If available the results of any diag nostic tests should be reported If the recorder has an installed modem it may prove to be helpful in diagnosing the problem from the MICRO AIDE factory The user will be asked to provide the appropriate telephone number and correct password Symptom or Problem Resolution No indication of power Verify 10 to 36Vdc at B and N power terminals Inspect fuse on Processor PCB PC does not display data Check cable connection to Terminal Port Verify cable is assembled per Figure 7 on page 85 Check Baud rate setting Check if Terminal LED on front panel illuminates Data at PC is garbled Check Baud rate setting Verify following setting 8 data bits 1 start bit 1 stop bit Printer connected to Terminal Port is Use Pause and Resume commands to prevent over missing data flowing data buffer of printer Table 6 Guide to Trouble shooting Techniques CHAPTER 5 MAINTENANCE Highlight cannot be moved at PC Set the PC for ANSI emulation Initial Check out Procedure
66. ey to complete the command Analog The Analog command is used to configure the four Analog Inputs of the CWR 22xt Each Analog Input can be used to monitor AC or DC voltages or currents Like a DVM the CWR 22xt can report its measurements using several different scales and resolutions Analog Inputs that vary beyond an acceptable range of operation can be reported by setting appropriate Limit Values Refer to the section entitled Low and High Limits on page 24 for additional details Data similar to the following will be displayed after selecting the Analog command A01 25 5Vdc Slow Low 25 6 High 25 5 The Analog Input number is displayed in the upper left hand corner To select a different Analog Input press the up or down arrow keys repeatedly Alternatively press the Browse key to jump to a different input Specify the Input Number by pressing the appropriate numeric keys Leading zeros ate not required Press the Enter key to jump directly to the selected input The first row Note CHAPTER 4 DISPLAV AND KEVPAD also indicates the Range and Filter settings The Low and High Limit values are listed in the second row To change the Range setting highlight the existing setting and press the Enter key until the desired Range is displayed The sequence of possible Range settings is 25 5 Vdc 51 1 Vdc 255 Vdc 25 5 Vac 255 Vac 25 5 Adc and 25 5 Aac The Filter setting controls the amount of smoothing the measured signal
67. eypad and display screen located on the front panel This allows the user to effectively operate the recorder without additional peripheral devices However each recorder will support applications that require file storage of Event Records An RS 232 port is provided that can be connected to the communications port of any personal computer The PC is then used to retrieve store and review Event Record data of interest to the user The PC can also be used to set up the recorder An optional 33 600 Baud internal modem can be installed that allows the user to remotely access and operate the recorder A standard phone line connection allows the user to gather critical Event Records from any location however distant The modem can also be used to provide dial out alarm reporting to a maintenance facility All MICRO AIDE rail signal products including the CWR 22xt Event Recorder are designed to be easy to use and maintain Each design is based upon the premise that value and reliability start with attention to detail and a concern for usability rather than needless complexity Our goal in MicRO AIDE CWR 22xT USER MANUAL creating the CWR 22xt was to provide the rail signal industry with an instrument maintainers and signal technicians will find easy to operate long after the recorder has been installed and set up Key Features Listed below are just a few of the many features included with every CWR 22xt Event Recorder The storage capacity is
68. f text Sample records for each input type are shown below D 14 57 54 699 04 06 03 GateDwnl Down LCD Event Record Digital Input CHAPTER 4 DISPLAY AND KEYPAD A 14 58 03 335 04 06 01 AC Power Fail LCD Event Record Analog Input V 14 58 03 402 04 06 03 Pwr Fail Alarm On LCD Event Record Virtual Input Each record consists of six fields The first character is always the input type designator The letters D A and V are used to specify Digital Analog and Virtual Input records respectively The first line also includes the time and date the event was logged to memory The time is specified to the nearest thousandth of a second The date is formatted as MM DD The start of the second line includes the Input Number e g 03 for the type designator listed It is followed by the eight character Input Identifier e g GateDwn1 and Event Name e g Down Input Identifiers and Event Names are described in Input Names Identifiers D on page 26 and Event Names E on page 25 respectively Browse Mode Browse Mode is most commonly used to view Event Records via the LCD panel Event Records may be viewed in either forward or reverse chronological order Events are selected by date and time and optionally by Input Number However two additional features allow the user to inspect the current status of an input or to measure the flash rate of a flashing circuit To access any of the Browse options press the Browse key The fo
69. ff 0 664 0 664 The Input Number and flash rate measured in flashes per minute are listed in the first row The average on and off intervals of each flash pulse measured in seconds are listed in the second row The lesser value is the optimum value to be assigned as the Detection Time for inputs using the reported flash rate Press the Esc key to exit the Flash Rate command and return to Idle Mode Setup Mode Setup Mode allows the user to set up the CWR 22xt to a specific set of application requirements The various commands that can be executed from the keypad form a subset of those performed via a peripheral device Only a few commands are not applicable to the keypad e g Transfer Files The results from any keypad performed command are indistinguishable from those performed from a peripheral device Accordingly the setup descriptions that are a part of Chapter 2 may be used to provide a more detailed explanation of the keypad commands Note CHAPTER 4 DISPLAV AND KEVPAD To enter Setup Mode from Idle Mode press the Setup key The following message will be displayed The user must enter the correct Passcode before any setup command can be executed Enter the passcode The factory default Passcode is 12345678 Passcodes are assigned numeric values only Press the Enter key to complete the entry If the user fails to enter the correct Passcode an error message will be displayed Assuming the correct Passcode is entered the
70. gits multiplesiot NA Current Sensor ae eee Excessive Train Speed DE 9 female used with CWR CS Internal Modem optional 5 to 99mph or 5 to 180 mph Type dependin on distance settin ji e isei ng Controls V 34 33 600 Baud data Kevpad compression and error correction Virtual Inputs 20 kevs located on front panel Usage Quantitv LCD Contrast Adjust Remote access via auto answer 8 user assigned 20 turn potentiometer located on operation ip Processor PCB Allows dial out alarm reporting of Definitions Virtual Input records Any logical association shared by Indicators Compliance 1 to 4 variables i e Digital iii t ECC part 68 Analog or Virtual Inputs LCD Panel ee rde o meg pa Includes LED back lighting for Assigned by defining the state of a Juliet enhanced visibility the Virtual Input for each combi Dial out Alarms optional nation of variable states Displays numerous command Reporting menus for configuring the Calling Method recorder and retrieving data Pri i Creates standard Event Record rimary and secondary dial Rel b i hi db h LEDs 3 numbers multiple attempts elav can be controlle eac PA Input al Power green Tone or pulse dialing Modem optional can be set up Terminal green flashes with Data to dial out Event Record send rcv data Issues Event Record for enabled Modem green flashes with Virtual Inputs Train Speed Monitor send rcv data and ring in Op ration lt _ Internal Clock Reports excessive train speed via Anal
71. he recorder for visual damage It should not be scratched dented or deformed in any way If it appears the recorder was damaged in shipment the responsible carrier should be notified immediately MICRO AIDE will assist the user in filing a claim in the event damage was sustained during shipment Initial Check out Procedure Before the CWR 22xt is installed at a signal facility it is recommended that an operational check of the recorder be performed The following materials are required as a part of this procedure e 12Vdc power source Common hook up wire for power and testing inputs 12 to 22 AWG Wire strippers and small flat head screwdriver e PC equipped with a communications program e g HyperTerminal or Procomm Plus set to operate at 38 400 Baud Digital Voltmeter DVM Perform each step in the sequence listed below If a problem arises refer to the section entitled Trouble shooting Guide on page 80 Figure 1 on page 6 and Figure 2 on page 7 illustrate a typical CWR 22xt installation MicRO AIDE CWR 22xT USER MANUAL CWA 22xt Event Recorder gt lt gt B 2 3 Browse we G 5 6 Alpha Terminal 8 9 Setup ww b A Decimal Esc we B gt Enter Micro AIDE 11 12 13 14 15 16 17 18
72. he relationship of the Low and High Limit Values to the Analog Input state Each region defines the type of Event Record that is created by transitions of the Note CHAPTER 2 INSTALLATION AND SETUP input The figure depicts an Analog Input configured to monitor a typical 12 Vdc battery source The figure indicates that the unacceptable region includes all voltages less than 10 2 Vdc and all voltages greater than 14 5 Vdc The unacceptable region always consists of two portions separated by the acceptable region If the input is within the range extending from 10 2 to 14 5 Vdc the battery voltage is considered to be acceptable Active On Event 14 5 Vdc Inactive Off Event Normal Operation 10 2 Vdc Active On Event Figure 4 Analog Input Operating Regions vs Limit Values Analog Inputs with levels greater than the Low Limit Value but less than the High Limit Value will create Event Records defined by the inactive or Off Event state Levels found to be outside these limits will create Event Records defined by the active or On Event state Event Names E There are two types of Event Records Active Event Records are created when a Digital Input is found to have sufficient input voltage greater than 5 Vdc or when an Analog Input transitions into its unacceptable region as defined by its Limit Values Conversely inactive Event Records are created when a Digital Input has less than 2 Vdc or an
73. ided with the recorder can be used for this purpose To attach the shelf mounting brackets remove the four rubber feet The screws and threaded holes vacated by the rubber feet are used to install the brackets If a PC is to be used it must be properly secured Contact MICRO AIDE in the event 19 rack mounting brackets are required Refer to Appendix B for ordering details Site Preparation The equipment location must have access to a stable 10 to 36 Vdc power source A pair of wires must be run from the power source to the location where the recorder will be mounted The CWR 22xt wire ends must be stripped approximately 1 4 The stripped ends will be secured by screw down terminals located along the left end panel of the recorder One wire must be connected to the positive voltage of the power source and the other wire must be attached to the CHAPTER 2 INSTALLATION AND SETUP return of the power source The screw down terminals will accept wire sizes as large as 12 AWG The two wires must be properly secured to prevent damage It is preferable not to run the wires adjacent to electrical equipment such as motors that may generate large electrical disturbances The Digital and Analog Inputs use the same screw down terminals as those required by the power leads Each wire should be tagged with its circuit identity Each input cable or wire bundle should be secured to prevent damage to the connections at either end The CWR 22xt can be progra
74. iefly displayed at the completion of the boot up procedure MICRO AIDE CWR 22xt V1 12 The reference to firmware version 1 12 may vary The firmware version number should be recorded and saved in the event service ever needs to be performed on the unit After the boot up procedure is completed the recorder will automatically enter Idle Mode There are three opera tional modes each is described in the following sections Idle Mode Except as noted below the real time clock and Unit Name are displayed during Idle Mode It is the at rest condition of the recorder An example of the real time clock display is shown below The first twenty characters of the Unit Name are listed in the first row Refer to the section enti tled Unit Name on page 19 for additional information KKKKK NOT SET KKKKK 16 35252 04 06 02 The CWR 22xt utilizes the 24 hour military time convention e g 7 00PM is shown as 19 00 00 The date and time display is interrupted once every minute for five seconds Alternating messages referring to the Setup and Browse Modes are displayed during this period The real time clock display is also interrupted in Idle Mode when new Event Records are logged Each new event will be displayed only briefly This process is useful in verifying that the recorder is continuing to detect events The Event Record format used by the LCD is described in the following section Event Record Format Event Records consist of two lines o
75. igned Digital Input Names Digital Input 01 Digital Input 02 etc Analog Input Names Analog Input 01 Analog Input 02 etc Virtual Input Names Virtual Input 01 Virtual Input 02 etc Digital Input Identifiers DinputO1 DInputO2 etc Analog Input Identifiers Alnput01 Alnput02 etc Virtual Input Identifiers Vinput01 VinputOZ etc On Event Name On all pairs Off Event Name Off all pairs Assigned Event Name Pair 1 Table 1 Factory Default Settings MicRO AIDE CWR 22xT USER MANUAL Digital Input Detection Time 3 000 seconds Digital Input flash status No disabled Analog Input Range 25 5Vdc Analog Input Filter speed Slow Analog Input Low Limit 25 6Vdc Analog Input High Limit 25 5Vdc Virtual Input Variables none assigned Virtual Input relay control No disabled Virtual Input modem control No disabled Train Speed First Sensor Input None assigned Train Speed Second Sensor Input None assigned Train Speed Distance Between Sensors 0 Train Speed Distance Units Inches Train Speed Excessive Speed Limit Omph Flash Rate Input last assigned Table 1 Continued Factory Default Settings The following precaution will be displayed after selecting the Reset Setup Data command RESET ALL SETUP DATA TO FACTORY DEFAULTS ARE YOU SURE No Yes Select No to abort the reset Select Yes to proceed Note The Reset Setup Data command will return the Termi
76. igure 3 illustrates the algorithm used by the CWR 22xt to detect flashing events The Detection Time must be set to the nominal duration of a flash pulse Pulses are expected to be on and off for the same duration However the CWR 22xt is designed to allow for some vati ation in the duration of each pulse Each on and off pulse must have a duration in the range from 75 to 125 of the assigned Detection Time Use either of the two methods listed below to determine the correct Detection Time for inputs with non varying flash rates Tip CHAPTER 2 INSTALLATION AND SETUP Voltage Flash Event Flash Event On Off 5t036V The duration of each On and Off Pulse must be within 75 to 125 of the assigned Detection Time Figure 3 Typical Flashing Pulse Seguence The Measure Flash Rate command can be used to determine the Detection Time for Flashing Inputs Refer to the section entitled Measure Flash Rate M on page 45 Alternatively the correct Detection Time in seconds is equal to 30 divided by the number of flashes pet minute i e 30 fpm To enable an input for flashing operation simply highlight the field in the Flash column and press the Spacebar Analog Configuration A The four Analog Inputs of the CWR 22xt can be used in a variety of applications Battery volt ages AC voltage levels and current flows can be measured and reported by the Analog Inputs The user can select an entry from a preset menu that bes
77. ill be rounded to the nearest fifteen minute value Accordingly the count of seconds will be cleared to 00 000 As an example if the time is 12 16 03 951 the clock sync feature will set the clock to 12 15 00 000 If the time is 12 44 20 263 the clock sync feature will set the clock to 12 45 00 000 The Clock Sync Input will normally be connected to the output of a PLC The time between successive PLC output pulses must be a whole multiple of 15 minutes Otherwise the recorder clock will indicate a significant error Additionally the Detection Time setting for the Clock Sync Input must be less than the duration of the PLC output pulse Refer to the section entitled Detection Times on page 22 for details Detect Times Flash Enable D The Digital Inputs of the CWR 22xt will generally be connected to relay based control circuits Since relay contacts typically bounce the recorder must have the ability to de bounce these inputs The Detection Time feature allows the user to establish a validation time for each Digital Input MicRO AIDE CWR 22xT USER MANUAL Tip Each Digital Input can also be set to monitor a flashing circuit The Detect Time Flash Enable command allows the user to program each of these features A typical response to the Detect Time Flash Enable command is shown below Only the first several lines of text are shown Detect Times Flash Enable Detect Input Time Flash 3 000 DO2 3 000 The procedure for programming
78. in the following procedures Later versions of these programs may be slightly different However the fundamental approach will remain valid HyperTerminal 1 With the mouse click on the Transfers command then the Receive File command The Receive File dialog box will open Verify that the Xmodem protocol is selected 2 Select the correct disk drive and folder Click the Receive button The Receive Filename dialog box will open 3 Enter a filename e g setup_10 bin The three character file extension must be defined If the various settings are correct click on the OK button 4 An information box will automatically open It will indicate the progress of the transfer After a few seconds depending upon the Baud rate the information box will close automatically to indicate a successful transfer MicRO AIDE CWR 22xT USER MANUAL Note Procomm Plus 1 With the mouse click once on the Receive File icon near the top center of the Procomm Plus window The icon appears as a downward pointing arrow The Procomm Plus Receiving File using Xmodem dialog box will open N Select the correct disk drive folder and filename e g setup_11 xmd If the various settings are correct click on the Save button 3 An information box labeled Xmodem will appear It will indicate the progress of the transfer After a few seconds depending upon the Baud rate the information box will close and the PC may beep to indicate that the transfer is c
79. ined as the abnormal occurrence of two or more relay states The normal operation of the circuit predicts that only certain relay states can occur It follows that any deviation from these normal states suggests a failure that should be flagged and carefully examined Identifying failures that occur as the result of abnormal relay states is greatly simplified by using the Virtual Input feature Each CWR 22xt allows as many as eight Virtual Inputs to be defined Each Virtual Input is defined by specific logical associations among particular physical inputs or other Virtual Inputs Virtual Inputs are defined by two essential properties The first property concerns the selection of variables Variables are merely the inputs physical or virtual that will be checked to determine if a Virtual Input event is to be logged The number of variables that define the Virtual Input can range from one to four Variables can be Digital Inputs Analog Inputs or other Virtual Inputs Assigning a Virtual Input as a variable to another Virtual Input is referred to as nesting Nesting allows the user to create a higher level Virtual Input that evaluates more than four variables The second property pertains to the state of each assigned variable A fault condition in a relay based circuit can only be identified if the state of each variable is properly evaluated The state of a variable is defined by the CWR 22xt as either On or Off Both states are described below
80. ing the setup parameters can be permanently saved on the hard disk or a diskette for later retrieval via the Upload Setup Data command CHAPTER 2 INSTALLATION AND SETUP To initiate a download or upload of the Setup Database execute the Transfer Files command The following sub menu will be displayed Both procedures are described in the following sections Xmodem File Transfer D Download Setup Data CWR to PC U Upload Setup Data PC to CWR Saving the Setup Database D Before the Setup Database can be saved the PC and communications program must be properly configured The following list describes the correct configuration Transfer protocol Xmodem Connection If the recorder s Terminal Port is being used select Direct connect Com1 or Direct connect Com2 whichever is available If the modem is being used the host modem must be logged on with the recorder e Baud rate as required by the recorder port set to N 8 1 Note The failure to select the proper transfer protocol i e Xmodem is the most common mistake made in this procedure To save the Setup Database to a PC file select the Download Setup Data command The following message will be displayed Sending Setup Data via XMODEM Ctrl X to stop The steps necessary to complete the download depend upon which communications application is being used The following sections describe the HyperTerminal and Procomm Plus methods respectively Windows 98 was used
81. ious data fields that comprise a record and separates them with a comma Intervening spaces are eliminated The processing application will place the record fields into cells or fields that satisfy its own processing requirements This formatting technique is frequently referred to as Comma Separated Values CSV When the Record Type is set to Comma the Include Details setting is ignored All Event Records for the selected time period will be issued and similarly formatted Listed below is a typical response to the Query Events command when the Record Type is set to Comma In the interest of brevity only two Event Records are listed MicRO AIDE CWR 22xT USER MANUAL Note 18 16 48 04 06 02 WkKEKK NOT SET RRR E RN 00r 0 0 0r 0r 0 070r 0r Or Or 0r 0r Or Op Ly lp Ur Or 0 Up by O70 0r 0 0 0 1 14 57 54 699 04 06 NS Gate Down Relav ON 1 LASSE SOs 395 04 06 VNC Tremere Laon WON Le Each report includes a three line header The content of the header is fully described in the following e Line lists the time and date the report was generated e Line 2 lists the user assigned Unit Name The default name is shown above Line 3 contains a bit map that indicates the state of each Digital Analog and Virtual Input at the moment just prior to the first Event Record listed Starting from the extreme left Digital Inputs 1 through 18 are represented In the sample data cited above Digital Inputs 17 and 18 are reported as active
82. ke sure that nothing is connected to an Analog Input if it is assigned as a current input Never connect a Current Sensor input to an Analog Input that has a voltage source connected Damage to the Current Sensor or improper operation of the voltage source may result Firmware Option Switches SW2 The CWR 22xt also includes a second switch assembly labeled SW2 that is used to enable or disable various firmware based options Generally the options are customer specific in nature Set the SW2 switches in accordance with the documentation that accompanies the specific option CHAPTER 5 MAINTENANCE Power Fuse J9 Modem LEL JF1 1Amp Telephone Line i F2 vane 85 0083 Relay Modem PCB Terminal Fuse optional Port LCD Contrast Adjust LI Firmware To Kevpad Option PCB gt Switches Off SW2 n PROCESSOR ensor 85 0059 REV D ya SW Analog Input MICRO AIDE Switches Figure 6 CWR 22xt Processor PCB Installing the Optional Modem The CWR 22xt can be equipped with a 33 600 Baud internal modem The optional modem provides accessibility to remote users of the recorder Unlike commercially available external modems the CWR 22xt modem will operate over the entite temperature range applicable to the recorder It uses the internal power of the CWR 22xt rather than commercial AC power Generally the Modem PCB is ordered at the time the recorder is purchased and is pre installed at the factory If the modem was not
83. l Input Check Primary and Secondary Dial Numbers Internal relay will not operate Perform Relay Test command Verify relay is enabled by Virtual Input Disconnect the external circuit attached to the relay contacts test again CWR CS Current Sensor is installed but current readings are O Set Analog Input Switches to on position Visibility of LCD characters is poor Adjust LCD contrast Table 6 Continued Guide to Trouble shooting Techniques This completes the User Manual for the CWR 22xt Event Recorder As an aid to the user four appendices have been provided They include detailed specifications and options applicable to the CWR 22xt Appendix C includes information pertaining to the CWR CS Current Sensor Appendix D includes a complete Bill of Materials for each sub assembly Any comments the reader may have on how to improve this manual are welcomed Comments should be forwarded to the Director of Marketing MICRO AIDE Corporation MicRO AIDE CWR 22xT USER MANUAL User Notes APPENDIX A A TECHNICAL DATA Specifications Phvsical Size Length 9 2 Height 6 3 Depth 2 2 Weight 2 5lb Environmental Storage Temperature 50 C to 85 C Humidity 0 to 95 non condensing Operating Temperature 40 C to 72 C Humidity 0 to 95 non condensing Mounting Standard shelf or back board mounting includes brackets Optional 19 rack mounting brackets available Construction
84. labeled correctly Additionally it can be used to determine if the inputs are operating properly and if the assigned Detection Times are set in accordance with the characteristics of the monitored circuits Measure Flash Rate M Note Typical railroad operating procedures require that the flashing rate of crossing signals be periodi cally measured and reported The Measure Flash Rate command allows the CWR 22xt user to precisely determine the flashing rate of a circuit Enabling the Measure Flash Rate feature imposes several pre conditions upon the Setup Database of the recorder The circuit to be measured must be connected to a Digital Input The selected Digital Input will be assigned a Detection Time of 1 seconds This will insure that the flashing pulses will not be filtered out by the de bounce properties of the Detection Time feature Refer to Detection Times on page 22 Finally the selected Digital Input cannot be enabled as the Clock Sync Input Refer to Clock Sync Input on page 21 for additional information The CWR 22xt will automatically adjust the Digital Input s Detection Time setting to 1 seconds and disable its Clock Sync setting when the Measure Flash Rate command is executed These settings will be automatically restored to their prior values when the measurement is concluded The following Edit Fields will be displayed after the Measure Flash Rate command is selected Measure Flash Rate Tigowic ice Misers
85. lecting the Print Setup Data command Print Setup Data Print All Print Event Names Print Input Names Identifiers Print Detect Times Flash Enable Print Analog Configuration Pimi Vircoal Trounce Print Measure Speed Parameters Print System Parameters B E T D A V M S The Print All command can be used at the end of the Setup Procedure to display the entire Setup Database The remaining commands are used to display specific portions of the Setup Database Tip The Print All command will issue a lengthy stream of data that will exceed the viewing capacity of a single terminal screen The user may wish to temporarily pause the data for better viewing Refer to the procedure entitled Data Flow Control on page 15 Transfer Files T A CWR 22xt will require a considerable amount of data entry if every input is assigned an Input Name Detection Time Event Name pair etc that differs from its factory default value In the event of an accidental loss of data memory e g a reset performed by mistake each Input Name Detection Time and Event Name pair will need to be re entered The Transfer Files command provides the user with a quick and simple data exchange alternative to re entering the Setup Data base by hand The Download Setup Data command is used to transmit the Setup Database to a data storage system A PC running a communications program like HyperTerminal or Procomm Plus makes an ideal storage system A file contain
86. limited to repairing or replacing at its sole discretion any defective product which is returned in accordance with the MICRO AIDE Material Return Policy Product that has been subjected to abuse misuse alteration accident lightning damage neglect or unautho rized installation or repair shall not be covered by this warranty MICRO AIDE reserves the tight to make a final decision as to the existence of any failures and the cause of such failures No warranty is made with respect to custom equipment or products produced to buyer s specifications except as mutually agreed upon in writing MicRO AIDE CORPORATION 685 Arrow Grand Circle Covina CA 91722 Tel 626 915 5502 Fax 626 331 9484 E mail support micro aide com
87. llowing message will appear Browse Events Status Flash Each of the three options are described in the sections that follow Records After selecting the Events option a table of dates similar to the following will be displayed 040602 040702 040802 040902 041002 041102 At least one Event Record must be logged for each date listed Dates are listed in the MMDDYY format The Events option may list as many as 128 dates Only six dates are listed in the example cited above The up and down arrow keys can be used to scroll quickly through a large collection MicRO AIDE CWR 22xT USER MANUAL Tip of dates Press the Enter kev after highlighting a date The displav will then specifv a start time as shown below Browse Event Records Start Time 00 00 00 Press the ESC key if records starting from midnight are to be inspected To inspect records starting later in the day perform the following steps 1 Using the left and right arrow keys position the highlight in the hour minute or second field 2 Press the Enter key to select the highlighted field 3 Enter the required hours minutes or seconds by pressing the appropriate numeric keys Leading zeros are not required 4 Press the Enter key to complete the entry 5 Repeat the previous steps to adjust the remaining fields After the correct starting time is specified the Esc key should be pressed The following message describing the use of the arrow keys will be briefly display
88. log Inputs and 1 to 8 for Virtual Inputs Leading zeros are not required 3 Move the highlight to the right Assign the remaining variables using the previous step Not all fields need to be assigned a variable To remove a variable press the O key or simply delete all of the characters in the field 4 Move the highlight to the field in the column labeled Relay Press the Spacebar to select the desired setting The Yes setting will operate the internal relay if the Virtual Input definition is satisfied The internal relay will remain in its energized state for as long as the conditions that define the Virtual Input persist The No setting leaves the relay unaffected by the Virtual Input 5 Move the highlight to the field in the column labeled Dial Out Press the Spacebar to select the desired setting The Yes setting will allow the internal modem if installed to dial the telephone numbers defined by the Primary and Secondary Dial Number parameters Refer to Primary and Secondary Dial Numbers on page 20 If the modem is able to connect with the far end an Event Record for the Virtual Input will be issued 6 Press the F1 function key to proceed to the next step CHAPTER 2 INSTALLATION AND SETUP A sample response listing three variables is shown below To complete the definition of the Virtual Input the state of each variable must now be assigned Virtual Output Function Oniepwe DOM A04 V03 App Lite Batterv VInput03
89. mes Flash Enable Analog Configuration Virtual Inputs Measure Speed System Parameters Print Setup Data ReSsCrmovs Gem a to eel R lt lt OARA Time Date T The CWR 22xt time stamps all Event Records Therefore the correct time and date must be set The recorder will automatically account for leap year The recorder s clock circuitry will continue to keep time even if power is interrupted for a prolonged period To change the time or date execute the Time Date command The sample data listed below shows a typical response to the Time Date command Time Date HH MM SS Times 09 57 54 MM DD YY Date 04 06 02 Saturday The highlight may be moved to the hour minute or second time fields or month day or year date fields The CWR 22xt utilizes a military style clock Accordingly 12 01 02 AM is defined as 00 01 02 and 12 59 58PM is defined as 23 59 58 Leading zeros are not required The day of week is displayed automatically as determined by the date selected by the user The clock of the CWR 22xt can be synchronized to an external source that is connected to a Digital Input Refer to the section entitled Clock Sync Input on page 21 Tip If the clock cannot be synchronized to an external source MICRO AIDE recommends that the clock be set at least once per week To complete the command press the Esc key The user can then accept or abandon the changes Reset System R The Reset System command can be used
90. mm Plus window The icon appears as an upward pointing arrow The Procomm Plus Send File using Xmodem dialog box will open N Select the correct disk drive folder and filename e g setup 11 xmd If the various settings are correct click on the Open button Go An information box labeled Xmodem will appear It will indicate the progress of the transfer After several seconds and a pause depending upon the Baud rate the information box will close and the PC may beep several times to indicate that the transfer is complete A total of 1664 bytes will be transferred p Ifthe transfer is successful a message similar to Transfer complete setup 11 xmd will appear in the lower left hand corner of the Procomm Plus window After the successful completion of the transfer the CWR 22xt will issue the following message MicRO AIDE CWR 22xT USER MANUAL Upload completed Press anv kev to continue The following message will be issued if the file is not promptiv sent after initiating the upload Transfer error Press anv kev to continue The user can then make a second attempt by selecting the Upload Setup Data command again Log Off X Note The Log Off command is used to terminate Administrative and Restricted Access sessions If the previous user logs off of the recorder access can be regained only by entering the correct pass word If the previous user fails to log off a second user will be allowed access without
91. mmed to issue an alarm indication signal A form C relay with normally closed and normally open contacts is available at the connector where power is attached to the recorder The contacts are rated for 2Adc at 24Vdc and 1 Aac at 125 Vac The relay can be used to control an external light or warning device Peripheral Equipment If a PC is to be co located with the CWR 22xt an appropriate AC power source must be available The Terminal Port cable should be kept to a minimum distance preferably less than 20 MICRO AIDE provides as a standard feature an RS 232 DE 9 to DE 9 cable This cable is suit able for use with most PCs In the event a DE 9 to DB 25 cable is needed either contact MICRO AIDE or purchase a DE 9 to DB 25 converter at any computer supply store If the CWR 22xt is equipped with the optional internal modem a standard telephone line must be attached to the recorder The telephone line must be terminated with an RJ 11 connector like those commonly used in residential telephone service Test the telephone line first to ensure that a dial tone is available Cabling Tip Follow the steps listed below to complete the cabling installation Power 1 Ensure that the power is off at the power source 2 The two wires from the power source must be secured to either pair of sctew down terminals labeled B and N respectively 3 Connect AC power to the PC as required The power input and alarm relay wires all termin
92. mory to be cleared The Administrative Password should be known to a limited number of users with a genuine need to know Restricted Access permits only limited access to the recorder It allows the user to review but not alter the Setup Database and Event Record memories The Restricted Password can be shared with users that only need access to Event Record data when investigating an incident or resolving a maintenance issue The Administrative and Restricted Passwords are defined similarly Each may be assigned any combination of alphanumeric characters not exceeding eight total To defeat the password secu rity system assign one of the passwords a null value This can be done by deleting all of the characters in the password field and then accepting the empty field When the password challenge is issued the user will be able to access the system by simply pressing the Enter key Care should be exercised in assigning and saving the Administrative Password If it is lost or forgotten it will be necessary to contact MICRO AIDE for assistance Passcode The CWR 22xt can be effectively programmed and operated from its front panel The Passcode is used to protect the recorder from unwanted access via the front panel It must be entered when the user attempts to alter the Setup Database The Passcode can be assigned any combination of digits not exceeding eight total Alphabetic characters cannot be assigned to the Passcode Ring Count The Ring C
93. multaneously The data flow will be stopped indefinitely To Resume data flow press the Ctrl and Q keys simultaneously This tech nique can be used to freeze the data at the PC Another useful command is the Abort command At any time during a lengthy data dump the remaining data can be ignored or aborted by pressing the ESC key The user can then issue another command immediately after the Abort is executed rather than wait until the lengthy data dump is completed Main Menu The Main Menu of commands will be displayed immediately after logging on Refer to the sample data labeled Main Menu on page 9 The Setup Procedure described in this chapter will famil iarize the user with the Setup Transfer Files and Log Off commands listed in the Main Menu For the remainder of this chapter the Setup Transfer Files Log Off commands and their numerous sub commands will be described in the sequence recommended by MICRO AIDE for their execution as part of the Setup Procedure Each command will be identified by its name as listed in the menu where it resides The single letter code that executes the command will be listed in parenthesis The Setup Procedure commences with the execution of the Setup command listed at the top of the Main Menu MicRO AIDE CWR 22xT USER MANUAL Setup S The following menu of sub commands will be displayed after executing the Setup command Setup Menu Time Date Event Names Input Names Identifiers Detect Ti
94. nal Port Baud rate to its default setting of 38 400 Baud The PC Baud rate may have to be adjusted Reset Event Memory E The Reset Event Memory command will permanently remove from memory all Event Records that were previously logged Records from each of 128 possible days will be deleted The following precaution will be displayed after selecting the Reset Event Memory command ERASE ALL EVENTS FROM MEMORY ARE YOU SURE No Yes Select No to abort the reset or Yes to proceed If a reset is performed the following precaution will be displayed Erasing memory do not turn power off for 60 seconds Press any key to continue CHAPTER 2 INSTALLATION AND SETUP Caution It is important that the user not turn off the power while the CWR 22xt is clearing the Event Record memory Reset Both B The Reset Both command allows the user to clear both databases simultaneously The precaution noted in the preceding paragraph applies to this command as well System Parameters S System Parameters are those parameters that affect the recorder as a whole They do not affect individual inputs or their behavior System Parameters include but are not limited to the Unit Name passwords and modem options The nine System Parameters are defined with a single command containing multiple fields A typical response to the System Parameters command is shown below The use of each System Parameter is described in the following sections System Parameter
95. nd delay A total of twenty alphanumeric characters can be entered for each of the dial numbers The CWR 22xt attempts to establish a connection by dialing the Primary Dial Number first If the connection fails the next attempt is made to the Secondary Dial Number Successive failures will force the modem to dial alternately between the two numbers The modem ceases further attempts after ten failures to each number have occurred The CWR 22xt modem is programmed to accept only reliable connections Consequently the fat end modem must be programmed to establish connections that use error correction protocols such as LAP M and MNP 2 4 Clock Sync Input The CWR 22xt contains a real time clock that allows the recorder to time stamp Event Records to the nearest thousandth of a second With any clock a small amount of drift can be expected The CWR 22xt clock will drift approximately one minute per month The clock sync feature allows an external signal to set the recorder s clock to the nearest fifteen minute mark To synchronize the CWR 22xt clock to an external input enter a Digital Input number in the Clock Sync Input field The input entry must take the form Dnn where nn must be in the range of 1 to 18 Leading zeros are not required The Clock Sync Input is treated like any other Digital Input Changes in state of the Clock Sync Input will create Event Records When the input transitions to an active state i e voltage applied the clock w
96. nds A value of zero prevents the input from detecting events The DTimes command is used to establish a unique Detection Time for each Digital Input The command is also used to enable an input as a Flashing Input Refer to Detect Times Flash Enable D on page 21 Data similar to the following will be displayed after selecting the DTimes command Inp DetTime Flashing DOL 3 000 No The default settings are displayed in the sample data cited above The Digital Input number is listed at the start of the second line Press the up or down arrow keys repeatedly to select a different input Alternatively press the Browse key to jump to a different input Specify the Input Number by pressing the appropriate numeric keys Leading zeros are not required Press the Enter key to jump directly to the selected input To change the Detection Time for the selected input press the Enter key while the existing value is highlighted A blank field with a cursor in the left most position will be displayed Enter a value by pressing the appropriate number keys Use the decimal point labeled Decimal to enter a fractional value Leading zeros ate not required Press the Enter key to accept the new value To set an input as a Flashing Input position the highlight in the Flashing field Press the Enter key to change the existing setting Yes enables the input as flashing No disables the input After all of the new settings have been assigned press the Esc k
97. nel The second ribbon cable connects the Processor PCB to the Keypad PCB These cables have fourteen and sixteen conductors respectively When removing the cover assembly the cables may need to be disconnected To reconnect the cables simply seat them into their respective connectors The connector end of each cable is keyed Do not force the connector end into place It should fit snugly but easily Diagnostic Testing The Main Menu of commands for the CWR 22xt includes the Diagnostics command Refer to the sample data labeled Main Menu on page 9 The Diagnostics command can be used to quickly verify the operational integrity of several hardware elements of the CWR 22xt Each of the five tests can be performed at any time They are non destructive and therefore will not alter the Setup Database or Event Record memoties The following menu of commands will be displayed in response to selecting the Diagnostics command System Diagnostics Checksum Test Program Memory Flash Memory Test Modem Test Keypad Test Relay Mest Each command performs a specific test The tests are described in the following sections Checksum Test Program Memory C The Checksum Test reads every memory address location used to store the program code As part of the reading process a checksum is calculated and displayed at the completion of the test The CHAPTER 5 MAINTENANCE same checksum must be calculated each time the test is performed Any vari
98. nge of Event Recorders that vary significantly in capacity size and features The MICRO AIDE Crossing and Wayside Recorder Model 22xt hereinafter referred to as the CWR 22xt provides its user with the most comprehensive set of features of any recorder presently available It is a companion product to the larger CWR 72 and CWR 264 recorders It is ideally suited for use at grade crossing wayside and small interlocking facilities Its small size belies its many capabilities Along with eighteen optically isolated Digital Inputs the CWR 22xt is equipped with four general purpose Analog Inputs Unlike other systems the use of Analog Inputs does not reduce the number of available Digital Inputs The Analog Inputs can be used to monitor both DC and AC signals such as battery levels commercial power voltages or relay coil voltages Analog DC and AC currents can be monitored by using the CWR CS Current Sensor MICRO AIDE s Failed Lamp Detector FLD 2 can be used in conjunction with the CWR 22xt to detect burned out bulbs in wayside facilities Hight Virtual Inputs allow the user to create Event Records based upon a specific logical associa tion of several physical inputs both analog and digital The Virtual Input feature can be very useful in analyzing failure conditions or in creating alarm indications Tedious and confusing site specific profiles are not required when using the Virtual Input feature Every CWR 22xt comes equipped with a built in k
99. number of records included in the report is always specified A checksum is also included The checksum is calculated from the first character of the first record through the last character of the last record Any report that issues the same set of records will always list the same checksum value regardless of when the report was generated Accordingly alteration of the record data can be detected provided the original data and checksum are known View Events V The View Events command allows the user to display Event Records in real time Immediately after an event is detected its corresponding Event Record will be issued to the Terminal Port or modem This command can be very useful in tracking events that are occurring while the user is online with the recorder It can also be used effectively during the Initial Check out Procedure to verify that each input is properly cabled The following message will be issued after the command has been selected View Events Report Include Details Yes Inputs blank all Fl Execute Report ESC cancel MicRO AIDE CWR 22xT USER MANUAL The Event Records of interest to the user can be qualified bv the two fields listed in the View Events Report The use of each of these fields is described in the following sections Include Details This setting allows the user to select the level of detail to be included in each Event Record Refer to the section entitled Event Record Formats on
100. og Input A4 Accuracy Typical 1 minute per month Logs standard Event Record MICRO AIDE reserves the right 20ppm Sensors are wired to 2 spare EP A to make changes at its sole Digital Inputs Sync spare Digital Input used to discretion to any specifications ex synchronize real time clock listed herein Limit Values Resolution l 5 to 99mph or 5 to 180mph l 2 Event Records are time stamped cele between to nearest 001 seconds 36 to 99 or 8 to 5280 Operation gt kull Full calendar auto adjusted for ao leap year Connectors Non volatile with power off Digital and Analog Inputs V2K compliant Detachable screw down 12 or 8 terminals each 12 to 22AWG Terminal Port DE 9 male configured as DCE APPENDIX A TECHNICAL DATA Terminal Port Cable The following cable is included with every CWR 22xt Terminal Port of CWR Comm Port of PC Configured as DCE Configured as DTE DE 9 Female DE 9 Female Pin Signal Pin 1 2 3 4 5 6 il 8 9 1 2 3 4 5 6 7 8 9 Shield is not attached Figure 7 Terminal Port Cable Wiring Diagram MicRO AIDE CWR 22xT USER MANUAL User Notes APPENDIX B B OPTIONS AND ACCESSORIES Options Accessories Internal Modem Current Sensors 85 0083 33 600 Baud V 34 V 32bis V 32 V 22bis CWR CS Current sensor for all CWR series V 22 and V 21 V 42bis and MNP 5 data compression recorders AC or DC currents 5 to 25 5A MNP 2 4 and LAP M error correction HCS 4
101. omplete A total of 1664 bytes will be transferred gt If the transfer is successful a message similar to Transfer complete setup 11 xmd will appear in the lower left hand corner of the Procomm Plus window After the successful completion of the transfer the CWR 22xt will issue the following message Transfer complete Press any key to continue The following message is issued if the file is not promptly opened after initiating the download Transfer error Press any key to continue The user can then make a second attempt by selecting the Download Setup Data command again Restoring the Setup Database U Before the Setup Database can be restored to the recorder it must have been previously saved Refer to the procedure entitled Saving the Setup Database D on page 33 The PC and communications program must be properly configured before the Setup Database can be restored The following list describes the correct configuration Transfer protocol Xmodem Connection If the recorder s Terminal Port is being used select Direct connect Com1 or Direct connect Com2 whichever is available If the modem is being used the host modem must be logged on with the recorder e Baud rate as required by the recorder port set to N 8 1 The failure to select the proper transfer protocol i e Xmodem is the most common mistake made in this procedure To restore the Setup Database to the recorder from a PC file select the
102. on Electrostatic discharges can cause serious damage to electronic components When handling circuitry inside the recorder it is recommended that the user wear a wrist grounding strap Adjusting the LCD Contrast Caution The contrast level of the LCD panel may occasionally need to be adjusted to compensate for extreme variations in ambient temperature To adjust the contrast level simply adjust the potenti ometer labeled LCD Contrast in Figure 6 on page 73 The Processor PCB is equipped with two other potentiometers that are set and sealed at the factory Do not attempt to alter these settings Switch Settings Caution There are two DIP switch assemblies mounted on the Processor PCB Each DIP switch assembly contains four switches Labeling on the body of the switch assembly indicates the on and off posi tions for each switch The location of each switch is illustrated in Figure 6 on page 73 Analog Input Switches SW1 The Analog Input Switch labeled SW1 is used to configure the CWR 22xt for use with the CWR CS Current Sensor To assign an Analog Input to the Current Sensor the switch for that input must be closed To assign the input as a voltage input the switch must be opened Analog Inputs A1 through A4 use switch positions SW1 1 through SW 1 4 respectively An Analog Input must be enabled as a voltage input or a Current Sensor input never both To ensure this open the appropriate switch for voltage operation and ma
103. on changing the Baud rate Note The CWR 22xt requires no parity 8 data bits and 1 stop bit i e N 8 1 3 Set the PC to emulate an ANSI terminal by doing one of the following 9 If HyperTerminal is being used click on the File Properties command Select the Settings tab Enable Terminal keys Select ANSI from the Emulation drop down list box If Procomm Plus is being used the ANSI BBS setting should appear in the lower left hand corner of the Procomm Plus window If the correct setting does not appear click on the current setting then select ANSI BBS from the pop up menu 4 Apply power to the PC Ensure that the communications program is set for a direct connec tion to the appropriate communications port 5 Apply power to the CWR 22xt The LED labeled Power located on the front panel should illuminate After a few seconds the date and time should appear on the Liquid Crystal Display LCD The date and time may need to be changed The procedure for changing the date and time is described in the section entitled Time Date T on page 16 6 Shortly after power is applied the PC will display the following message Micro Aide CWR 22 Flash Boot Loader Press ESC for boot loader Caution The preceding message should be ignored Do not press the ESC key The user must wait several seconds for the CWR 22xt program to load into executable memory 7 After the program is loaded the following password challenge will be displaye
104. ond ot third user Remote Operation The setup procedures and operational capabilities of the CWR 22xt can be exercised remotely provided the recorder is equipped with a MICRO AIDE internal modem The modem will operate at speeds up to 33 600 Baud It provides industry standard error correction and data compression features A PC equipped with a modem and a communications program makes an ideal remote access system Event Records and other data from several remote CWR 22xt recorders can be easily gathered and saved to either a hard disk or diskette file There are two steps the remote user or host system must perform before remote access is possible Each of these steps is described in the following section Establishing a Modem Connection A standard telephone line must be attached to the modem of the CWR 22xt To access the recorder the host system must dial the telephone number of the CWR 22xt and wait for an answer The recorder s modem will answer after a predetermined number of rings Refer to the section entitled Ring Count on page 20 The modems will then handshake The handshake ensures that the modems can communicate with each other at an appropriate speed A connection is established upon the successful completion of the handshake MicRO AIDE CWR 22xT USER MANUAL Note The CWR 22xt will only permit reliable connections to be established The host modem should be programmed for MNP 2 4 or LAP M operation Entering the Pass
105. onological sequence The power on event will immediately follow the power off event The time between the two Event Records indicates the period during which no logging was possible All of the Analog Input measurements for S1 records will be reported with a zero value This is done to eliminate erroneous readings Upgrading the Firmware Note Like any microprocessor based product the CWR 22xt executes a stored memory program The program referred to as firmware is saved in a Flash Memory chip Flash Memory chips are uniquely characterized by their permanent storage and multiple write properties Their use allows the CWR 22xt firmware to be upgraded to a newer version by simply uploading a new program file The more common practice of shipping and replacing a Programmable Read Only Memory PROM chip does not apply to the CWR 22xt Consequently there is no need to open the unit to gain access to the Processor PCB The firmware upgrade procedure is normally performed via a PC connected to the Terminal Port of the recorder It cannot be performed via the front panel keypad An upgrade can be performed MicRO AIDE CWR 22xT USER MANUAL remotely if the recorder is equipped with the optional internal modem In such cases MICRO AIDE support personnel can perform the upgrade at the request of the user Before the upgrade can be performed the PC communications program e g HyperTerminal or Procomm Plus must be properly configured The following
106. operate the CWR 22xt from the Terminal Port and modem The user should remember to use the Log Off command to end the current session Refer to Log Off X on page 36 The next chapter describes the use of the front panel LCD and keypad MicRO AIDE CWR 22xT USER MANUAL User Notes CHAPTER 4 4 DISPLAY AND KEYPAD Introduction The CWR 22xt is designed to provide its user with the greatest degree of versatility and function ality All MICRO AIDE Event Recorders come equipped with a front panel mounted Liquid Crystal Display LCD and keypad Together these features allow the user to perform all of the setup and operational procedures required to effectively use the recorder The advantage to the user is that a PC or printer although helpful is not required to operate the recorder Setup and operation of the CWR 22xt from the front panel is somewhat different than operation via a peripheral device The tasks to be performed and the end results are identical but the methods employed are different This chapter describes the methods that are unique to front panel operation Figure 1 on page 6 provides an illustration of the LCD panel and keypad Front Panel Description Liquid Crystal Display The LCD panel consists of a display approximately 3 2 by 7 in size It is configured to present two lines of data Each line can contain twenty alphanumeric characters and symbols The LCD characters are large and can be viewed easily f
107. ount parameter determines the number of ring cycles that must occur before the modem will answer an incoming call Setting the Ring Count to a sufficiently large value will allow an on site maintainer to answer a voice call prior to the CWR 22xt answering The Ring Count can be set in the range from 0 to 99 A setting of 0 will disable the modem s auto answer feature i e incoming calls will not be answered by the modem The following message will be displayed below the last field in the Systems Parameter command if the optional modem is not installed No message will appear if the modem is installed Modem is NOT installed Primary and Secondary Dial Numbers The Virtual Input feature of the CWR 22xt allows users to program a fault reporting capability into the recorder If the fault is detected and the recorder is equipped with the optional internal modem the modem can be enabled to dial out to a maintenance facility and transmit an Event Record that specifies the fault Note Caution CHAPTER 2 INSTALLATION AND SETUP The telephone number the modem dials is defined by the Primary and Secondary Dial Number parameters Dial numbers will generally contain numeric values An exception to this rule is that parentheses hyphens and space characters can be placed into the number field for clarity These characters will be ignored by the modem Additionally the comma character can be placed anywhere in the field to create an arbitrary two seco
108. owing three sections The Train Speed Monitor is always disabled by its factory default settings Excessive train speed is reported in a time stamped Event Record Refer to the section entitled Event Record Formats on page 46 Figure 5 on page 31 illustrates a typical Train Speed Monitor installation First Second Sensor Input The First and Second Sensor Input fields can be assigned any valid Digital Input number Leading zeros ate not required The values can be non consecutive or in ascending or descending order The Train Speed Monitor reports motion in either direction with a positive value CHAPTER 2 INSTALLATION AND SETUP To Digital Input 36 to 99 in or 8 to 5 280 ft Train SS motion To Digital Figure 5 Typical Installation Train Speed Monitor The two Digital Inputs assigned to the motion sensors are subject to the following treatment e Previously enabled Clock Sync Flashing Input and Measure Flash Rate settings will be auto matically disabled Contact closures from either sensor will not result in Event Records being logged to memory The Detection Time for each input will be automatically set to 005 seconds to de bounce the sensor output signals The user will not be able to alter the Clock Sync Flashing Input Measure Flash Rate and Detection Time settings To regain control of these settings the Train Speed Monitor must first be disabled Note To disable the Train Spee
109. pgrst uvwxyz lt gt _ 3 Press the Enter key to select the highlighted character The selected character is placed into the name at the present location of the cursor The cursor is then automatically moved one position to the right 4 To enter a number into the name press the appropriate number key To correct an error repo sition the cursor under the character in error and overwrite it with a new character To insert a space assuming no characters have been inserted to the right simply move the cursor to the right The space characters follow the upper case Z in the character set 5 Repeat the previous steps until the name is completed 6 Press the Enter key to accept the newly defined name Alternatively press the ESC key to retain the previously assigned name ot to start again by ignoring all of the character entries Clock The Clock command is used to change the date or time The time is always listed in 24 hour mili tary style format e g 7 00PM is listed as 19 00 00 In accordance with this convention the user must enter the time by using the same format The date is always listed in MM DD YY format as shown below Time 16 07 09 Date 04 06 02 Sat To change the date or time position the highlight in one of the numeric fields Press the Enter key Enter a valid one or two digit number leading zeros are not required Press the Enter key to accept the new value Adjust the other fields as required The
110. previously ordered the user may wish to install the modem after delivery of the recorder To install the modem follow the steps listed below 1 Completely remove the recorder s cover assembly in accordance with the procedure entitled Working Inside the Recorder on page 71 2 Locate the sixteen pin male connector labeled J9 MODEM near the upper right hand corner of the Processor PCB The modem connector is illustrated in Figure 6 on page 73 Temporarily remove the 6 32 1 4 screw and lock washer secured to the hex stand off located near the modem connector 3 Install the Modem PCB component side up by mating its sixteen pin female connector with the Processor PCB connector Use the 6 32 screw and lock washer to secure the modem to the hex stand off Reassemble the recorder MicRO AIDE CWR 22xT USER MANUAL When the CWR 22xt is reinitialized the firmware will automatically detect the modem s presence and configure it for auto answer and originate operation Replacing the Fuses There are two fuses mounted on the Processor PCB The fuses are designed to protect the input power source and the contacts of the output relay Each are rated at 1A and conform to the 2AG size standard Before replacing a fuse the cause of the blown fuse should be ascertained and cleared if possible Reconnecting the Internal Cables There are two ribbon cables inside the CWR 22xt The first ribbon cable connects the Processor PCB to the LCD pa
111. r criteria Several seconds may be required to locate the first record 4 Use the arrow keys to inspect additional records for the specified input The Browse key can be pressed again at any time if a different input is to be inspected Press the Esc key to exit the Query by Input Number procedure and return to Idle Mode The CWR 22xt will log an Event Record to memory when the power is turned off as well as on These records are referred to as System Records and are associated with S type inputs Refer to the section entitled System Events on page 77 for additional details Status The Status option allows the user to inspect the current state of each input The status of Digital Analog and Virtual Inputs is indicated by their assigned Event Names Voltage and current measurements ate reported for Analog Inputs The Input Status feature can be of great use when setting up the recorder Without a peripheral device the user can verify that inputs are assigned proper Input Identifiers and Event Names Each input can be checked to verify that it will report a change of state Additionally the command provides a DVM like function for each Analog Input After selecting the Input Status option the following message will be displayed briefly Use gt to scroll Browse select input The arrow keys can be used to scroll from one input to the next Digital Inputs are followed by Analog Inputs They are followed by Virtual Inputs Rather than
112. r keys To assign a null Passcode press the Enter key instead This will effectively disable the Passcode protection feature Access to the recorder will be permitted by simply pressing the Enter key when the request for Passcode message is displayed Accept the new Passcode by pressing Enter Press the Esc key to complete the command If the user forgets the assigned Passcode the System Parameters command should be executed It will display the current Passcode assignment Refer to System Parameters S on page 19 Modem optional The CWR 22xt can be equipped with an optional internal 33 600 Baud modem The modem option allows remote users to access the recorder Additionally the modem s dial out feature allows Event Records from Virtual Inputs to be transmitted to a remote maintenance center There are three parameters that control the operation of the modem The Ring Count determines the number of rings that must occur prior to the modem answering an incoming call The Primary and Secondary Dial Numbers identify the number to dial when attempting to transmit a Virtual Input record Refer to Primary and Secondary Dial Numbers on page 20 for additional infor mation regarding these parameters Data similar to the following will be displayed after selecting the Modem command Rings Prim Sec 2 To change the Ring Count setting move the highlight to the field labeled Rings and press the Enter key Enter a number in th
113. r the desired Edit Field is highlighted the user may type any combination of alphanumeric characters appropriate to the field The initial value of the field is completely removed after typing the first character Consequently it is not necessary to delete each character that comprises the initial value Errors in typing can be corrected by using the Backspace key At any time while editing a field the user may press the ESC key and thereby restore the field to its previous value Uppet and lower case letters may be used Limit values are assigned negative values by preceding the numeric entry with a minus sign Numeric values that exceed the range of the field are auto matically set to the maximum or minimum value as appropriate permitted by the range To accept the new value assigned to an Edit Field the user can either press the Enter key or move the highlight to a new field The initial value of an Edit Field cannot be restored after the new value has been accepted When all of the fields contain values suitable to the user the command may be completed Once a field has been accepted by pressing the Enter key or moving the highlight it may depending upon the command be programmed into the recorder as an updated operating param eter Accordingly the acceptance may occur before completion of the command CHAPTER 2 INSTALLATION AND SETUP Completing Commands Generally commands are completed by pressing the ESC key However pressing the
114. rocessor to complete Modem found 33600 Hit any key If a modem is not installed or the microprocessor is unable to communicate with the modem the following message will be displayed Modem found NONE Hit any key Relay The following message will be displayed after the Relay test is selected Relay 1 l ON 2 0FF Press the 7 key to energize the relay Press the 2 key to un energize the relay The internal relay and any circuitry attached to the relay contacts will be tested Press the ESC key to complete the test The relay will immediately assume the un energized state when the Esc key is pressed Press any key to exit the test Note The user may wish to contact MICRO AIDE customer service if a failure occurs as the result of any diagnostic testing Instructions on how to proceed will be offered Material Return and Limited Warranty policies are described on the inside back cover of this manual Caution CHAPTER 4 DISPLAY AND KEYPAD RESET The Reset command should be used with caution It allows the user to selectively restore the entire Setup Database to its factory default values or to clear the Event Record memory Refer to Reset System R on page 16 for additional information The following message will be displayed after the Reset command is selected Erase Setup Data Event Memory To restore the entire Setup Database to its default settings highlight the Setup Data field and press the Enter key Select Yes
115. rom several feet away The super twist design of the LCD panel provides a viewing angle of 20 from the level of the display As a convenience to the user the contrast level of the display may be adjusted This can be helpful when the recorder is exposed to very hot or cold temperatures The potentiometer that controls the contrast level is mounted on the internal PCB Refer to the section entitled Adjusting the LCD Contrast on page 72 for details Keypad The keypad contains twenty individual keys Each key consists of a pushbutton switch They ate clearly labeled as to their various functions The keys are spaced 75 apart to minimize double hits A special editing technique allows alphabetic characters to be entered via the keypad The left lt and right gt arrow and Enter keys also provide for quick menu item selection Except while selecting a command ot performing the special editing procedure the left arrow key may be used to backspace over characters when an incorrect number has been entered MicRO AIDE CWR 22xT USER MANUAL Note Unless otherwise stated characters shown in italics are used to refer to specific keys on the keypad e g Browse This convention is used throughout the remainder of this chapter How to Use the Keypad After power is applied the CWR 22xt will perform a firmware boot up procedure The LCD will remain blank for 10 to 15 seconds while the recorder is booting The following message will be br
116. rrect disk drive folder and filename e g CWR 22xt V112 bin If the various settings are correct click on the Open button 3 An information box labeled Xmodem will appear It will indicate the progress of the transfer The information box will close automatically The following message will be displayed to indi cate the completion of the transfer End of file transfer completed Hit any key to continue MicRO AIDE CWR 22xT USER MANUAL 4 Press any key to display the following menu of commands Menu U Upload new program to Flash memory D Display sample of uploaded code F Display flash R Run main program Enter Command 5 Press the R key followed by the Enter key to run the program just loaded The request for a password message will be displayed and normal operation of the recorder will commence Note After completing the firmware upgrade procedure it may be necessary to execute the Reset System command A reset should be performed only if recommended by MICRO AIDE customer service technicians Refer to Reset System R on page 16 Trouble shooting Guide The following guide is provided to assist the user in resolving problems that may occur with the operation of the CWR 22xt It can be especially helpful when attempting to operate the recorder for the first time Procedures for resolving both local and remote problems ate listed Where multiple steps are indicated it is recommended that they be performed in the ord
117. s Unit Name kkk kk NOT SET kkk kk Terminal Port Baud Rate 38400 Administrative Password PASSWORD Restricted Password LOOKWORD Passcode 12345678 Ring Count Primary Dial Number Secondary Dial Number Clock Sync Input Unit Name The Unit Name serves as a comprehensive recorder and site ID Data from several CWR 22xt recorders can be easily distinguished by providing each unit with a unique and descriptive name A total of eighty alphanumeric characters can be used to define the Unit Name It may include city milepost street and DOT designation data It is assigned using standard Edit Field techniques described in Working with Fields on page 14 Terminal Port Baud Rate The Terminal Port Baud rate may be assigned one of ten values Valid settings are 300 600 1200 2400 4800 9600 19200 38400 57600 and 115200bps Press the Spacebar to select a Baud rate The following message will be displayed if the Baud rate was changed Change baud rate now then Press any key to continue The user must change the Baud rate of the PC to match the new setting assigned to the CWR 22xt MicRO AIDE CWR 22xT USER MANUAL Caution Administrative and Restricted Passwords Access to the CWR 22xt via the Terminal Port and optional modem is protected bv a dual level password system Administrative Access permits unrestricted access to all recorder functions Administrative Access allows the Setup Database to be altered and the Event Record me
118. s less than 2Vdc The Analog Input level is within the accept able range as defined by the region between the Limit Values The Virtual Input evaluates to a false logic state CHAPTER 4 DISPLAV AND KEVPAD Press the Enter key to toggle the state of the Virtual Input from Off to On or vice versa This setting will apply only to the combination of variable states currently displayed To define the Virtual Input for the next combination press the down arrow key Listed below are the eight vari able state combinations associated with the Virtual Input described previously Each combination can be selected in the sequence listed by pressing the up or down arrow keys DO7 A04 Off Off Off Off On Off On Off Off On On On On In the sample data cited above the state of the Virtual Input is set in all cases to its initial value of Off Change the state of the Virtual Input as required by the remaining variable states Press the Esc key to accept the new settings and complete the command Speed The Speed command is used to configure the Train Speed Monitor feature Once parameters that comprise the feature are set the recorder will report train speed and instances of excessive speed Refer to the section entitled Measure Speed M on page 30 for additional information regarding these parameters The train speed feature uses Analog Input A4 to report speed Data similar to the following will be displayed after
119. s not previously altered any of the factory default settings and that the PC is connected to the Terminal Port of the CWR 22xt The Terminal Port default settings are 38 400 Baud no parity 8 data bits 1 stop bit i e N 8 1 The Setup Procedure involves several steps that permit the user to program a variety of parame ters that will best suit the user s recording requirements Each step involves the selection and execution of a particular command Before the actual programming is performed the user should be aware of several conventions employed by the CWR 22xt user interface User Interface Conventions Note Logging On User sessions are initiated only after the log on procedure is completed To log on the user must enter the correct password in response to the password challenge A typical password challenge message is shown in the sample data labeled Password Request on page 8 The factory default password is PASSWORD in upper case letters Complete the password entry by pressing the Enter key The Main Menu will be displayed after the correct password has been entered The user is allowed three password attempts MicRO AIDE CWR 22xT USER MANUAL Note Commands and Fields The CWR 22xt user interface allows commands and parameter fields to be easily and quickly selected Commands are listed vertically in a menu Some commands direct the user to sub menus containing additional commands e g Setup command Fields allo
120. selecting the Speed command Sensors Dist 0 Limit O There are five distinct parameters that must be assigned The two sensors must be assigned valid Digital Input numbers The separation between the two sensors is used to set the Distance param eter It can be set to any value in the range from 36 to 99 or 8 to 5280 The unit of measurement fot the Distance parameter can be set to inches or feet To change the unit of measurement setting move the highlight to the ptesent setting and press the Enter key Trains with monitored speeds in excess of the Speed Limit value will be identified by an Event Record The Speed Limit value must be in the range from 5 to 99 mph distance in inches or 5 to 180 mph distance in feet Setting any of the four parameters to zero will disable the Train Speed Monitor Complete the command by pressing the Esc key PCode The Passcode feature prevents unauthorized users from altering the Setup Database via the front panel Passcodes can contain any combination of numeric values not exceeding eight total MicRO AIDE CWR 22xT USER MANUAL Tip A message similar to the following will be displayed after selecting the PCode command Passcode 12345678 In the sample data cited above the Passcode is set to its default value To change the Passcode press the Enter key A blank field with the cursor in the left most position will be displayed Assign a new Passcode by pressing the appropriate numbe
121. side back cover of this manual CHAPTER 5 MAINTENANCE System Events Tip Event Records are normally created by a change in state of an input An exception to this rule concerns the cycling of power to the recorder Separate Event Records will be logged to memory whenever power is turned on and off Event Records of this type are classified as System Events To distinguish them the Input Number is always labeled as S01 Additionally the Input Name is labeled as System Power The Input Identifier is labeled as Power The Event Names are labeled as either ON or OFF These labels are fixed and cannot be changed by the user System Events can be reviewed using either of the two formatting options Record formats are described in the section entitled Event Record Formats on page 46 Listed below are two sample Event Records as they would appear at the PC In the interest of simplicity only the No Details single line form is shown 10 57 30 001 04 06 System Power 10 57 42 328 04 06 System Power The two records indicate that power was off to the recorder for approximately 12 seconds The first record listed above is also shown below as it would appear at the front panel LCD S 10 57 30 001 04 06 01 Power OFF System Events can be Queried and Browsed just like other Event Records Instead of selecting a D A or V input type designator select the S type System Events are always logged to memory in chr
122. t Name identifies the type of event detected at the input The Event Name listed will always be a member of the Event Name Pair assigned to the input The Event Names Down and Fail indicate clearly to the user the type of event that was recorded Input Number The Input Number is the last data field listed The record may be from a Digital D1 to D18 Analog A1 to A4 or Virtual Input V1 to V8 Include Details The Include Details format provides additional information concerning every Digital Analog and Virtual Input of the recorder It requires two lines of text Various symbols and numerical fields are used to represent input states and measured analog values The sample data shown below lists two Event Records using the Include Details format option By way of comparison the records shown are the same as those listed previously 14 57 54 699 04 06 NS Gate Down Relay GateDwnl Down D03 ii Dep RNA ta A XX 118Vac 11 2Vde 0 0Vdc 3MPH 14 58 03 335 04 06 AC Power 120V AC Power Fail AOl A 866 a imdir 0 0 00108 XX sex ilik ZWele 0 0Vdc 3MPH The content of each line of text is described in the following section First Line The first line of text is identical to that used by the No Details formatting option For additional information refer to No Details on page 46 Second Line The second line includes a set of symbolic and numerical data fields A group of three symbolic fields is used to indicate the state of each Digit
123. t suits the intended application A typical response to the Analog Configuration command is shown below Default settings are listed Analog Configuration Low Limit High Limit 14 25 5Wele gt m Rovde gt 25 5 4 25 Sele gt 25 5 ar 25 sele gt 25 5 Recommend Slow for AC MicRO AIDE CWR 22xT USER MANUAL The first column identifies the input Analog Inputs are consistently labeled by the CWR 22xt as A01 A02 etc The A prefix is always used to distinguish Analog from Digital and Virtual Inputs This first column of fields is fixed and cannot be altered by the user Four parameters can Tip be used to characterize an Analog Input Each parameter is described in the sections that follow Table 2 lists the Resolution Filter and Limit Values applicable to each of the seven Ranges Range Resolution Filter Low Limit High Limit 25 5Vdc 1Vde Slow or Fast 25 6 to 25 5Vdc 25 6 to 25 5Vdc 51 1Vdce 1Vdc Slow or Fast 0 0 to 51 1Vdc 0 0 to 51 1Vdc 255Vdc 1Vdc Slow or Fast 256 to 255Vdc 256 to 255Vdc 25 5Vac 1Vac Slow or Fast 0 0 to 25 5Vac 0 0 to 25 5Vac 255Vac 1Vac Slow or Fast 0 to 255Vac 0 to 255Vac 25 5Adc 1Adc Slow or Fast 25 6 to 25 5Adc 25 6 to 25 5 Adc 25 5Aac 1Aac Slow or Fast 25 6 to 25 5Aac 25 6 to 25 5 Aac Table 2 Analog Input Parameters Range The Range setting allows the user to configure the Analog Input for DC or AC voltage or DC ot
124. tal Inputs are entered as Dnn where nn is a number between 1 and 18 Analog Inputs are entered as An where n is a number between 1 and 4 Virtual Inputs are entered as Vn where n is a number between 1 and 8 Leading zeros are not required CHAPTER 3 OPERATION Multiple inputs can be selected by using the following methods Separate two Input Numbers by a single space character Select a contiguous range of inputs by including a hyphen between two n numbers The contiguous range option can be applied to Digital Analog and Virtual Inputs The set of Input Numbers must be terminated by pressing the Enter key The following example illustrates a typical Inputs field entry Inputs d2 IS 38 es dis wi Al 2 blank all As the example indicates the input type designator can be entered as an upper or lower case letter Input Numbers can be entered without regard to sequence Event Records for Digital Inputs 2 5 6 7 8 18 Analog Inputs A1 A2 A3 and Virtual Input V7 will be issued After the inputs are selected the user must press the F1 function key to complete the command Event Records will then be issued in accordance with all of the settings selected by the user Event Records will automatically cease being issued when the Report Type is set to Dump or Comma After the last Event Record a message similar to the following will be displayed Number of records 126 Checksum F515 End of report Hit any key to continue The exact
125. the section entitled Unit Name on page 19 for additional details A message similar to the following will be displayed after selecting the UName command KKKKK NOT SET KKKKK The first twenty characters of the existing Unit Name are displayed in the second line of text The default Unit Name is displayed in the sample data cited above To change the name press the Enter key Assign a new name ot modify the existing name by using the Alphanumeric Editing Procedure on page 58 Press the Esc key to complete the command Due to restrictions in the size of the LCD panel the UName command can be used to assign a Unit Name limited in length to twenty characters Lengthier Unit Names up to eighty characters must be assigned by selecting the Unit Name command from the Main Menu ENames Event Names are created by the user to uniquely identify Event Records By way of example only the state of an input can be labeled as Up or Down or GateUp or GateDwn Event Names add clarity to Event Records that would otherwise not be possible if input states were labeled as only On or Off Event Names are always assigned in pairs to identify the active and inactive state of an input As many as eighteen Event Name pairs can be assigned Refer to the section entitled Event Names E on page 25 for additional details CHAPTER 4 DISPLAV AND KEVPAD Data similar to the following will be displayed after selecting the
126. the recorder is ready to receive the new program file The next several steps depend upon whether the user is accessing the recorder via HyperTerminal or Procomm Plus Both procedures are listed below HyperTerminal 1 With the mouse click on the Transfers command then the Send File command The Send File dialog box will open Verify that the Xmodem protocol is selected 2 Select the correct disk drive folder and filename e g CWR 22xt V112 bin If the various settings are correct click on the Send button 3 An information box will automatically open It will indicate the progress of the transfer The information box will close automatically to indicate a successful transfer The following message will be displayed to indicate the completion of the transfer End of file transfer completed Hit any key to continue 4 Press any key to display the following menu of commands Menu U Upload new program to Flash memory D Display sample of uploaded code F Display flash R Run main program Enter Command 5 Press the R key followed by the Enter key to run the program just loaded The request for a password message will be displayed and normal operation of the recorder will commence Procomm Plus 1 With the mouse click once on the Send File icon near the top center of the Procomm Plus window The icon appears as an upward pointing arrow The Procomm Plus Send File using Xmodem dialog box will open 2 Select the co
127. to perform the reset or No to ignore the reset To completely erase all of the Event Records from the event memory highlight the Event Memory field and press Enter Select Yes to perform the reset or No to ignore the reset It is important that the user not turn off power to the CWR 22xt for 60 seconds after initiating a reset of the Event Record memory This concludes the chapter on how to operate the recorder from the front panel Since the setup of the recorder is critical to how the CWR 22xt will perform it is advisable to review any changes that may have been made to the Setup Database The next chapter describes general maintenance techniques that may benefit the user in case a problem symptom is ever encountered MicRO AIDE CWR 22xT USER MANUAL User Notes m EW MAINTENANCE Introduction The primary purpose of this chapter is to describe the recommended trouble shooting methods to be used with the CWR 22xt It should be referred to if ever a questionable symptom arises during the operation of the recorder The CWR 22xt is designed to provide its user with many years of trouble free operation There are no user serviceable parts inside the unit There are no consumable items or supplies that need to be replaced or replenished The user may occasionally need to wipe dust away from the external surfaces of the unit This should be done with a clean dry cloth The mechanical design of the chassis provides the internal elec
128. tronic assemblies with a nearly sealed environment Due to the low power consumption of the unit ventilation holes are not required The inside of the recorder should remain clean indefinitely Additionally MICRO AIDE printed circuit boards PCBs are sealed with a moisture and fungus resistant conformal coating Working Inside the Recorder The user may have occasion to work inside the unit to configure several switch settings The following sections describe several tasks involving work that may be performed inside the recorder Observe the steps listed below before attempting any task Refer to Figure 1 on page 6 and Figure 2 on page 7 They illustrate the front and end views of the recorder respectively 1 Remove power from the recorder by detaching the connector labeled Pwr located along the left end panel of the recorder 2 Remove all of the Analog and Digital Input connectors and peripheral cables 3 Remove the recorder ftom the shelf or equipment rack 4 Remove the two 6 32 1 4 screws from the front of the cover assembly Move the cover assembly aside being careful not to pull on the attached ribbon cables 5 If the task requires that the cover assembly be completely removed disconnect the cables that connect the Processor PCB to the LCD and Keypad PCB The task can now be performed safely After the work is completed reassemble the recorder by reversing the steps listed above MicRO AIDE CWR 22xT USER MANUAL Cauti
129. uire alphabetic charac ters to be used in the creation of a name or label e g Input Name The keypad however contains only numeric and function keys A special Alphanumeric Editing Procedure which is a feature of all MICRO AIDE Event Recorders allows the user to create names and labels from an extensive set of characters This procedure is described below Alphanumeric Editing Procedure The first step in the Alphanumeric Editing Procedure is to select the parameter that is to be edited e g Input Name or Input Identifier A flashing highlight is used to indicate a specific parameter To select the highlighted parameter press the Enter key A blank field of characters will be displayed An underscore i e _ will be positioned in the first character location The underscore character is used as a cursor in the Alphanumeric Editing Procedure The left and right arrow keys can be used at any time to position the cursor as required To create an alphanumeric name perform the following steps 1 Press the Alpha key The following list of characters will be displayed ABCDEFGHIJKLMNOPORST UVWXYZ amp Note CHAPTER 4 DISPLAV AND KEVPAD 2 Using the arrow keys reposition the highlight until the desired character is highlighted The up and down arrow keys can be used to select the following list of additional characters A total of eighty characters plus ten numbers are available for selection abcdefghijkImno
130. urrent operation Figure 8 on page 90 provides an illustration of the CWR CS Key Features There are several important features concerning the CWR CS the user may wish to consider Either AC or DC currents in the range from 0 to 25 5A can be measured Each input is completely isolated from the current carrying conductor The conductor is simply inserted through one of four holes in the unit e Hall Effect circuitry is used to provide a wide operating range and stable performance No adjustments or calibration steps are required prior to operation No external power connections are required The Event Recorder provides the power e The CWR CS can be located up to 15 away from the recorder e Each insertion hole will accommodate a conductor terminated with a 5 ring lug Installation and Setup Figure 8 illustrates a typical CWR CS installation The unit may be mounted in any orientation e g vertical or horizontal It is not sensitive to the earth s magnetic field The base of the unit provides four mounting holes A shelf or back board makes an ideal mounting platform The current carrying conductors to be measured must be inserted through the holes in the unit Turn the power off to the CWR 22xt Enable the required Analog Input circuits in the CWR 22xt by turning on the appropriate switches located on the main PCB of the recorder The correct procedure is described in the section entitled Analog Input Switches SW1 on
131. ut Procedure Installation Procedure Location Mounting Site Preparation Peripheral Equipment Cabling Power Alarm Relay Peripherals Input Circuits CWR CS Current Sensor Applying Power Setup Procedure User Interface Conventions Logging On Commands and Fields Data Flow Control Main Menu Setup S Time Date T Reset System R System Parameters S Detect Times Flash Enable D Analog Configuration A Event Names E Input Names Identifiers I Virtual Inputs V Measure Speed M Print Setup Data P Transfer Files T Saving the Setup Database D Restoring the Setup Database U MicRO AIDE CWR 22xT USER MANUAL Log Off X CHAPTER 3 OPERATION Introduction Multi User Operation Remote Operation Establishing a Modem Connection Entering the Password How to Operate the CWR 22xt Querv Events Q Start Time End Time Include Details Reverse Order Report Type Inputs View Events V Include Details Inputs Live Status L i Measure Flash Rate M Event Record Formats No Details Include Details First Line Second Line Svmbol Legend X upper case X lower case colon period asterisk exclamation mark equals sign blank CHAPTER 4 DISPLAY AND KEYPAD Introduction Front Panel Description Liquid Crystal Display Keypad How to Use the Keypad Idle Mode
132. w the user to either select or enter parameter values A specific field is always uniquely associated with a particular command To select a command from a menu or a field within a command simply move the rectangular highlight to the location of the desired command or field Pressing the appropriate arrow keys located on the PC keyboard will move the highlight The left right up and down arrow keys may be used in any sequence to position the highlight To execute a command that has been previously selected i e highlighted simply press the Enter key Alternatively the command may be executed by pressing the single letter code listed to the left of the command Upper and lower case letters may be used Every command listed in a menu has a distinct single letter code that permits immediate execution of that command Working with Fields The CWR 22xt utilizes two types of fields Selection Fields allow the user to select a parameter from a list of predefined values e g Terminal Port Baud rate Edit Fields can be set to any alphanumeric value desired by the user e g Unit Name To change the value of a Selection Field simply press the Spacebar on the PC keyboard The next value from a predefined list of values will be displayed each time the Spacebar is pressed The first value in the list will automatically follow the last value Input Names Detection Times and Limit Values are examples of parameters that are defined by Edit Fields Afte
133. wn arrow keys repeatedly Alternatively press the Browse key to jump to a different input Press the Alpha key repeatedly until the desired input type is displayed i e D A ot V Enter an Input Number by pressing the appropriate number keys Leading zeros are not required Press the Enter key to jump directly to the selected input The field labeled Id will initially be highlighted Move the highlight to the right to select the Input Name Press the Enter key to modify the highlighted assignment A blank field with a cursor in the left most position will be displayed Use the Alphanumeric Editing Procedure on page 58 to create a new Input Identifier or Input Name To assign an Event Name Pair to a specific Input Number move the highlight to the field labeled Event Press the Enter key repeatedly until the desired Event Name pair i e 1 to 18 is displayed Each time the Enter key is pressed the second line of text will be automatically updated to reflect the contents of the selected Event Name pair Pressing the Enter key while pair number eighteen is displayed will return the user to pair number one After all of the names and pairs are assigned press the ESC key to complete the command MicRO AIDE CWR 22xT USER MANUAL DTimes The Detection Time feature of the CWR 22xt is used to prevent relay contact bounce from logging false Event Records The Detection Time can be set to any value in the range from 000 to 32 767 seco
134. word Note Immediately after a connection is established the CWR 22xt will issue a password request similar to the following Model CWR 22xt Event Recorder Ver 1 12 C 2002 MICRO AIDE INC KKK KK NOT SET kkkix Event storage capacitv 190304 Enter password The host system must issue the correct password followed by an Enter Passwords are defined in accordance with the procedure entitled Administrative and Restricted Passwords on page 20 The default Administrative and Restricted Access passwords are PASSWORD and LOOKWORD respectively Passwords are case sensitive The host system is given three attempts to enter the correct password A third error will result in a disconnect by the recorder This procedure prevents unwanted users from accessing the recorder After the password is entered the user will be able to operate the recorder in a manner identical to that specified by local operation Accordingly the CWR 22xt will display the Main Menu of commands Refer to the sample data entitled Main Menu on page 9 How to Operate the CWR 22xt An explanation of each operational command is included in the remaining sections of this chapter Operational commands may be executed in any sequence The user may wish to perform operations in one sequence and then depending upon the observed data perform a different sequence of commands Each command is listed by its name as it appears in the Main Menu followed by its comm