Home
GI-2850 SI Inserter User`s manual
Contents
1. the bit rate Pressing ENTER to confirm and store the result pressing MENU to give up current operation 6 3 3 Set the time and date A Press MENU 3 times display as follow 3 0 SET DATE TIME 2007 5 24 01 30 33 B Press UP DOWN to change the parameters 3 0 SET DATE TIME Gospell GI 2850 SI inserter user s manual 2007 5 24 01 30 33 Pressing ENTER to confirm and store the result pressing MENU to give up current operation 6 3 4 Set the parameters of the files A Press MENU 4 times display as follow 4 000 0 FILE NUMBER 008 FILES B Press LEFT RIGHT to view or change the file attributes 4 000 1 USED MEM 254 KByte 4 000 2 VALID MEM 51 000 KByte 4 000 3 VALID RATE 02 100Mb s 4 000 4 STREAM RATE 01 000Mb s 4 000 5 STREAM ON ON Pressing UP DOWN to change the parameter pressing ENTER to confirm and store the result pressing MENU to give up current operation C Press UP DOWN to view or change the files parameters 4 xxx 0 FILE NAME Ttt ts 4 xxx 1 FILE SIZE 1504 Byte 4 xxx 2 SEND ON OFF 4 xxx 3 SEND RATE 01 000Mb s Pressing UP DOWN to change the parameter pressing ENTER to confirm and store the result pressing MENU to give up current operation Gospell GI 2850 SI inserter user s manual 7 System errors and debugging 7 1 Indicator status There are 3 LED indicators on the front panel as follow 1 POWER is the power supply indicator when turn on the power the indicator turns red that mean the
2. Gospell GI 2850 SI inserter user s manual GI 2850 SI Inserter User s manual Gospell GI 2850 SI inserter user s manual Menu 1 Safety instruction asn ea a a Ea A aR 3 2 Composition of the system and operating principle ssrrronrronvrronvrrrnrrrrnrrrrenvrrenrerennerennrrrnnrernnne 4 DH Composition OF the system usa Saeed det 4 2 2 Operating principle u seseessnskieniennsn an anna 4 3 Major features 25 24 ee ruser RE 5 4 Technicalispecifieation 2 3 seeren aent 6 4 1 Data pit er re Ed 6 42 Data output anna ara RE E A AEEA REEE EEEa 6 4 3 Network management interface srrronrrrrnrrrronrrrenvrrenrrrrnrrrrenrerennerennrrsnnrsrsnnersnnersnnerennsssnnnee 6 4 4 Power off status preserving enient reedene re iee ee a rera pEi etsh ores 6 4 5 POWEL SUPPIyea u 22 Tree Shan A a ende 6 4 6 Operating environment sisses e niione e aar E E EE ES EEEE EENS ESEE KEE E EEE Es T 4 7 Radiation and safety requirements eeeeesesssesssnensnnensnneennnennnnnennnennnneennnnnnnneennneensnnnne nenn 7 4 8 Mechanic l characteristic 2 2 02 seien in iadniat vindu indvidake 7 ANWeEICHE Na a a n illegalen 7 5 Connections vesdesecicedesedvendecedvcndesadevedescdacadesedevadesedavadesedevedescdavadesedevadescdsvadesadsvadesddsvadevedenadeseddvadesded 8 3 l P nekdisplayza tastatur eigen E E A EE 8 5 2 Fr nt panel sketch Map u week Ban an Bin eee En 8 5 3 Back panel Sketch Mapa ui Rn ee nern 8 6 Operations seinka r
3. a E EEE E EA EE Er A E E A E EAA Ta g 6 1 Keyboard functions a a a a e SEES 9 6 2 Mode select keyboard unlocked rrrronnrronvrrrnnrrrnnvrrenverennrrrnnrrrsnrerennerennersnneresrrsrsnserennenen 9 6 3 Change the parameters au usa ea be Seen 9 6 3 1 Set system parameters rrronrnrnnvonnnrnnrrnnvrnnrrnnrrrnrrnneenneenneennsennseressnnssnnssnnssnessnnssresnnee 9 6 3 2 Set the parameters of the output TS rrrrrrronrrronrrrrnrrrrenvrrenrrrsnnrrrsrrersnrerennerernnsrenne 10 6 3 3 Set the time and date i e cscs seen sinds in eisen hin een innen 10 6 3 4 Set the parameters of the files meninei arrea n E A a nennen 11 7 System errors and debugging isinsi oroin AEE EEE EEE EE EE AE Ran EEI RE Ea aa 12 Ta Mdieatorstaus edru 202 SEHR E A E O a a 12 Td Trouble ShoOtng nesnosne ana eee betes ence ae 12 7 2 1 The POWER indicator light does not illuminate sooenrronrnonrnenrnenrnenrnenrnevnnennne 12 7 2 2 STATUS illuminates in red ccecccecssccessecseseceeneeeeseeeeseeeeeseeeseeeseeesseeeneeeeeenes 12 7 2 3 ALARM flashes cccccsceeseesceseesseeseeseeseeseeeseeseeseceeeeseesecseceeeseesesseeeeeeaeeaeeeeeseeas 12 8 Network management een Beet Bein ikea 13 Gospell GI 2850 SI inserter user s manual 1 Safety instruction 1 Before starting using this unit please be sure to refer to this manual 2 Do not to open the cabinet otherwise the guarantee to repair are not available Meanwhile touching
4. les to the FPGA the FPGA sends the TS to CY7B923 by the setting bit rate then it achieves ASI interface s output Gospell GI 2850 SI inserter user s manual 3 Major features 100M 10Mbps Ethernet self adapting The total bit rate and the bit rate of each file can be set which can automatically inserts null packets The size of the TS packet can be set PID sequential counting value automatically updates Providing Chinese and English menu Supporting local and remote files operation Adopting LCD which can locally monitor system status and setting parameter in real time Power off memory Gospell GI 2850 SI inserter user s manual 4 Technical specification 4 1 Data input Input interface 1 DVB standard ASI interface Connector BNC Impendence 75Q TS standard IS0013818 1 Valid input bit rate max 214Mbps Each channel TS packet format 188 204bytes automatically identify TS input model equal break out irregular 4 2 Data output Output interface 8 DVB standard ASI interface Connector BNC Impendence 75Q Output TS standard IS0013818 1 Valid output bit rate 0 1 Mbps 40Mbps adjustable 1 Kbps step TS packet format 188 204bytes compatible There is no RS coding when in 204 bytes TS output model equal 4 3 Network management interface Ethernet interface IEEE802 3ethernet RJ45 interface 4 4 Power off status preserving It can preserve the status of last time when power resumes it ca
5. n automatically startup 4 5 Power supply Voltage 90V 250V AC Frequency 50Hz 2 Power 25W Gospell GI 2850 SI inserter user s manual 4 6 Operating environment Operating temperature 0 C 50 C Storage temperature 25 C 55 C Relative humidity 10 75 4 7 Radiation and safety requirements According with GB13837 92 and GB8898 88 standard 4 8 Mechanical characteristic 44 5mm height I U x483mm width 19 x400mm depth 4 9 Weight 5KG Gospell GI 2850 SI inserter user s manual 5 Connections 5 1 Panel display Power indication Status indication Failure alarm indication 5 2 Front panel sketch map D O n PA 4 a O GOSPELL poner T er STATUS M G 2850 SI Inserter ALARM Er Digital Video ENTER MENU LOCK Broadcasting AN PIC 1 GI 2850 front panel sketch map 5 3 Back panel sketch map I F 600000000 PIC 2 GI 2850 back panel sketch map Gospell GI 2850 SI inserter user s manual 6 Operations 6 1 Keyboard functions Move Right Left key Recycle the sub menu move cursor Move Up Down key Locate cursor change parameters ENTER Store the result select to execute LOCK Lock the key unlock remote control exit menu MENU Recycle main menu and cancel operations Note 1 Be sure to press ENTER after renewing the parameters all the new parameters will be available only without otherwise the old parameters still in keep 2 Under any statu
6. power supply works normally 2 STATUS if this indicator is green that means the status of input signal is normal 3 ALARM if this indicator is green that means the device works normally 7 2 Trouble shooting 7 2 1 The POWER indicator light does not illuminate Please check the wire to make sure the wire is connected to the socket properly and the power switch is on 7 2 2 STATUS illuminates in red This means input signal is abnormal please check the input data cable is connected properly Otherwise it means the unit is broken needs to be replaced 7 2 3 ALARM flashes This means the equipment is out of order for some faults Please debug according to the instruction from LCD Gospell GI 2850 SI inserter user s manual 8 Network management The unit could be controlled remotely via network management software It needs authorization Please refer to NMS user s manual
7. s of setting parameters press LOCK key will make unit return to the status of showing operating parameters 6 2 Mode select keyboard unlocked Press MENU to display main menu circularly Once 1 0 VIEW ALARMS ALARMS LIST EMPTY Twice 2 0 SET CODE RATE 02 000Mbps 3 Times 3 0 SET DATE TIME 2007 5 24 00 45 35 4 Times 4 000 0 FILE NUMBER 008 FILES 6 3 Change the parameters 6 3 1 Set system parameters A Press MENU once display as follow 1 0 VIEW ALARMS ALARM LIST EMPTY B Press UP DOWN key to view change parameters select functions 1 0VIEW ALARMS CLEAR ALL ALARMS C Press ENTER to store change or confirm operation 1 0 VIEW ALARMS ALL ALARMS BE CLEARED Gospell GI 2850 SI inserter user s manual D Press LEFT RIGHT to view sub menu 1 1 SET IP ADDR 120 120 120 160 1 2 SET NET MASK 255 255 255 000 1 3 NET GATE 120 120 120 001 1 4 NET STATUS NOT CONNECTED or CONNECTED 1 5 SERIAL No XXXXXXXXXXXXXXXXXX 18 digits 1 6 VERSION H XX XX S XX XX 1 7 GET PRESET PARAMETER FACTORY PRESET Press ENTER to store exchange 1 8 SAVE NOW PARAMETER SAVE IN NAMEOI Press ENTER to store the parameter 1 9 SELECT LANGUE ENGLISH Press ENTER to select the corresponding language E In any status pressing lock to exit 6 3 2 Set the parameters of the output TS A Press MENU twice display as follow 2 0 SET CODE RATE 03 000Mb s B Press LEFT RIGHT to set TS packet format 2 1 SET PACKET SIZE 188 Byte C Press UP DOWN to change
8. the inside makes you in great danger of electric shock 3 Please make sure to cut off the power supply if you will not use this unit in a long term and do not use any broken jack which could result in fire or electric shock 4 Wet hands are forbidden to touch the power jack to avoid risk of electric shock 5 Please pull the plug itself instead of the wire when you pull out power plug 6 Any thing flammable and metal or liquid which will destroy the unit must be kept out of the box 7 Do not place this unit in a location near a heat source such as radiator or air ducts or in a place exposed to direct sunlight excessive dust moisture rain mechanical vibration 8 Keep the device working in a good ventilative environment if not the destruction will occur 9 Please keep the packaging for the safety of transit Attention After setting all the parameters already please press lock after the LCD darkles that means locking succeed then all the protective functions will operate Gospell GI 2850 SI inserter user s manual 2 Composition of the system and operating principle 2 1 Composition of the system The block diagram of composition of SI inserter ARM ASI ial FPGA CY7B923 interface processor Keyboard 2 2 Operating principles By the Ethernet the ARM processor communicates with NMS take up control and files and save the files in the SDRAM Then the ARM multiplex and circular output the TS fi
Download Pdf Manuals
Related Search
Related Contents
«a MODE D`EMPLOI CHRONOGRAF`HE ANALOGIQUE 26 February 2005 CM310 Quad Serial Port utilityModule La dimension enveiculvurelle dans l PDF version - ARM Information Center CORRDATA II USER MANUAL - Rohrback Cosasco Systems • InstallatIon • FonctIonnement • entretIen - Alto Gestione risparmio energia Copyright © All rights reserved.
Failed to retrieve file