1.                                                               Drain joint installation    NOTE  The drain joint differ from appliance    to appliance     Fit the seal into the drain joint  then insert the  drain joint into the base pan hole of outdoor unit     rotate 90   to securely assemble them     Connecting the drain joint with an extension drain  hose  Locally purchased   in case of the water  draining off the outdoor unit during the heating    mode     Refrigerant pipe connection    1  Flaring work    Main cause for refrigerant leakage  is due to defect in the flaring work     Carry out correct flaring work    using the following procedure   A  Cut the pipes and the cable   1  Use the piping kit accessory or pipes    purchased locally    2  Measure the distance between the indoor  and the outdoor unit    3  Cut the pipes a little longer than the  measured distance    4  Cut the cable 1 5m longer than the pipe    length     B  Burr removal           cross section of pipe tube     N      Completely remove all burrs from the cut      Putthe end of the copper tube pipein a  downward direction as you remove burrsin    REFRIGERANT PIPE CONNECTION        Base pan hole of  outdoor unit    Drain pipe    Seal Drain joint                   Fig 53    Y X X X    A 90  Oblique Roughness Burr    cf V4 Z      v E o g                   Fig 54   O Pipe  Reamer    a SS    Point down       order to avoid dropping burrs into the tubing     C  Putting nut on  Remove flare nuts attached to i
2.                        gt   gt  WD oO                         Fig 60    Electrical work    Electric safety regulations for the initial Installation  1  If there is serious safety problem about the power supply  the technicians should refuse  to install the air conditioner and explain to the client until the problem is solved   2  Power voltage should be in the range of 90  110 of rated voltage   3  The creepage protector and main power switch with a 1 5 times capacity of Max  Current  of the unit should be installed in power circuit   4  Ensure the air conditioner is grounded well   5  According to the attached Electrical Connection Diagram located on the panel of the outdoor  unit to connect the wire   6  All wiring must comply with local and national electrical codes and be installed  by qualified and skilled electricians   7  An individual branch circuit and single receptacle used only for this air conditioner must be available              ELECTRICAL WORK       Wiring connection    NOTE  Before performing any electrical  work  turn off the main power to the system        cautions    e Do nottouch the capacitor even if you  have disconnected the power for thereis  still high voltage power on it  or electric  shock hazard may occur  For your safety   you should start repairing at least 5 minutes  later after the power is disconnected       The power is supplied from the Outdoor  Unit  The Indoor Units are connected  with signal wires or power cords are  connected reliably a
3.                       Model A Model B Model D  One three models   o BERAE o PEEPAR o PEREP    2 AE  L N OLANASA L  B  N B  S  B  L  C  N  C  S  C   Lt W2 OMAA L4 B  L28    B  L1    L2 C         PAPARRA      _IBIERIERIEBIERIER    g ED                                                                                                          ee TA odele    o PEPA o PEE ok s   K    L  B  N  B  S  B  L  C  N  C  S  C   PREEBIREB       L N OLANAS A  B  N  B  S  B  L  C  N  C  s  C   ra A  A                                     De                                                                                                                                                    One four models                                                                                                                                         EEE   fo of g D  L N OLOANASA Le NB  Si  LG NG SC  LO NO  S0  Lt 12 SINAIA Li  B  L218    B  L1    L2 0  S     anes  PAREPA O D RDO                                                             L1 L2 S       LTOLA me mwe mp  TOA                             T0 B    Model B    ModelA    ELECTRICAL WORK       NOTE please refer to the following figures if the client want wire by themselves     oR    oR E  EEAO    Eo PEA    EKK                                                                                                                                              LANs                   UAN SO                                              Model C    One five models   EEEE
4.           INSTALLATION INSTRUCTIONS       Indoor unit installation wall mounted type     1  Fitthe Installation Plate   1  Fitthe installation plate horizontally  on structural parts of the wall with  spaces around the installation plate    2  Ifthe wallis made of brick  concrete  or the like  drill five oreight 5mm diameter  holes inthe wall Insert Clip anchor for  appropriate mounting screws    3  Fitthe installation plate onthe wall  with five or eight type    A    screws     Note     Fit the Installation Plate and drill holes inthe  wall according to the wall structure and indoor  unit dimensions and the corresponding  mounting points on the installation plate  The  Installation Plate may be slightly different  according to the different models of indoor  unit  See Fig 5 for example    Dimensions arein    mm    unless otherwise  stated                                                                                                      Indoor unitdimension  Mountingdimensions   mm WxH  L Left   R Right   710x250 100 160  790x265 100 150  920x292 150 185  1080x330 70 105  790x275 100 85  930x275 150 205  998x322 100 120  680x255 170 92  770x255 170 95  905x275 80 100  750x280 180 110  835x280 140 110  990x315 260 135  1186x343 275 275  900x290 83 170  1045x305 100 170  715x250 85 88  800x275 100 95  940x275 110 100  1045x315 293 163  795x270 150 160  845x286 150 186  995x295 150 200  1084x320 150 140  850x275 100 130  900x285 150 90  1015x298 150 200  850x290 100 115       
5.          Left rear side  refrigerant  ipe hole  65    Correct orientation  of Installation Plate                AAAA    v    Fig 4    t 150mm or more to ceiling    Indoor unit outline       e a  xXx xX                                                                                    ae L z  Installation plate   R  120mm or    WO BA 120mm or  more to wall   more to wall        T   amp   iei id y W o Mit  eft rear side 5     A F  refrigerant        RE Fight feat side  pipe hole 65 l 4 pipe hol  Ww  Model A     150mm or more to ceiling  Indoor unit outline L   Installation plate    R  120mm or    120mm or  more to wall      z  more to wall       l    Left rear side Lt Right rear side  refrigerant F pr refrigerant  pipe hole 65 w pipe hole 65  F  Model B  T 150mm or more to ceiling  Indoor unit outline  L Installation plate  i  120mm or  more to wall  120mm or                    more to wall          Model C    Fig 5    2  Drill a hole in the wall    1  Determine hole positions according to the  diagramdetailed in Fig 5  Drill one  1  hole   65mm  slanting slightly to outdoor side    2  Always use wall hole conduit when  drilling metal grid  metal plate or the like     3  Connective Pipe and Drainage  Installation  Drainage  1  Run the drain hose sloping downward  Do  not install the drain hose as illustrated in  Fig 7   2  When connecting extension drain hose   insulate the connecting part of extension    drain hose with a shield pipe  do not let  the drain hose slack     Conne
6.         2  Remove the front panel   e Remove the string   Refer to Fig 50 7     e Allowing the front panel to fall forward will  enable you to remove it                                3  Remove the face plate   e Remove the four screws  Refer to Fig 50 7     e Opening bottom of face plate fora angle  that is 30 degrees  then the top of face       5 5 Connect the drain pipe Console   m Install the drain pipe of the indoor unit    The outlet has PTI screw bread  Please use  sealing materials and pipe sheath fitting   when connecting PVC pipes     A CAUTION      The drain pipe ofindoor unit must be heat  insulated  orit will condense dew  as wellas the  connections of theindoor unit      Hard PVC binder must be used for pipe  connection  and make sure there is no leakage      With the connection part to the indoor unit   please be noted notto impose pressure onthe  side of indoorunit pipes     INSTALLATION INSTRUCTIONS         When the declivity ofthe drain pipe downwards  is over 1 100  there should not be any winding       The total length of the drain pipe when pulled  out traversely shall not exceed 20m  when the  pipe is over long  a prop stand must be installed  to prevent winding      Refer to the figures on the right forthe  installation of the pipes     1 5m 2m    4 u s HT   acy                                                                  pgi  Insulating e declivity i  material lower than 1 100    Bend x  ml    ta S shape                   Put as deep as possible   
7.       gt 3 and  lt 6 0 75   gt 6 and  lt 10 1   gt 10 and  lt 16 1 5   gt 16 and  lt 25 2 9             Suggest Minimum WireSize   AWG American Wire Gage                  Appliance Amps  AWG Wire Size  10 18  13 16  18 14  25 12  30 10                Connection Cable    S    10mm 40mm                         Fig 62                   Terminalblockofoutdoorunit   lt                                  oO                                              Grounding                      POWER          waite       sated    Connective cable  of indoor unit ang    nitB  onnective cable  indoor unit and    o                               Connective cable  of indoor unit and        of indoor unit and                       outdoor unit utdoor unit        outdoor unit outdoor unit    IndoorunitB Indoorunit   Indoorunit E             i  I     i  1  i   i  i   Connecte cabe   I    i  I  i  1     1  i  L                One three        One four      One five    ELECTRICAL WORK    NOTE please refer to the following figures if the client want wire by themselves   please run the main power cordthrough the lower line outlet of the cord clamp        One two models                    7                         OED  o PRR   DERE  o Pee  EEE   EEEE  E o   RSE                                                                                           woe                                                                                    MA MB                                                                      
8.    Install 10  4 pieces hanging screw bolt    Determine the location of hanging screw bolt following Fig 40     Make sure to use the hanging screw bolt of 10     The treatment to the ceiling varies from construction  please consult the professionals for details   1  Treatment to ceiling   make sure to consolidate the roof beam for possible vibration to keep the ceiling horizontal   2  Please cut off the roof beam   3  Reinforce the place that is cut off and consolidate the roof beam      Carry out connection of piping and wiring inside the ceiling     Determine the piping direction  Especially in the case of existing ceiling  please pull the wire to the connection place before  overhanging the unit     Install the hanging bolt in following different situation     Wooden structure Original concrete bricks    Put a timber across the beams and install Install the hanging hook with expansible    the bolts  bolt into the concrete   Timber over the beam i            R  K Roof beam           Ceiling  Hanging screw bolts Fig 35  Fig 34  New concrete bricks Steel roof beam structre  Install with insertion or embedding screw  Install the supporting angle steel   Hanging screw bolt    l Steel bar    Blad   shape  Gide nserion  Zez  He hanging 1 i    ave snape eel and embedding ing bolt il   Supporting angle steel  insertion  screw bolt  pease    Fig 37    Fig 36       Overhang the unit             e Install the hanging screw bolt to the  U shaped slot of installation ear   Overhang the 
9.    L ae             Mounting bolt          D  Connecting point of  refrigerant pipe D gas side   E  Connecting point of   refrigerant pipe   E  Liquid side                                       Fig 49 12       235mm             2 1000mm       iY          Fig 49 13    A CAUTION   The figures aboe are based on model with  18000Btu h as rated capacity  which may  differ fromthe unit you purchased     INSTALLATION INSTRUCTIONS       4 5 The Dimension ofthe Unit e This manualis subjectto changes due to  Unit mm technological improvement without    further notices   Capacity Cc Mounting screw B    ST2 9x10 C H    a_i  ne  or J    Note The dimension of 12000Btu h and  18000Btu h are the same                              5  Floorand Standing Type   Console   Remote    5 1 Accessories Console  emote    Please check whether the following fittings Fig 50 1  are of full scope  If there are some spare    fittings  please restore them carefully  5 2 Inspecting and Handling the    O nwe eC unit Console   F 7 At delivery  the package should be  Installation Tools checked and any damage should be  reported immediately to the service agent   When handling the unit  take into account  the following   1       Fragile  handle the unit with care   L   2  ff  Keep the unit upright in order to  avoid compressor damage   3  Choose on before hand the path along  Remote which the unit is to be brought in   controller  ren pe j 4  Movethis unitas originally package as   on some  ST2 9 10 C H  possible  
10.   Turn off the unit immediately if leakage  happens  Check and find out the solution Fig 68  ways till the unit operate properly   D        TEST RUNNING         Gas leak check   1  Soap water method   Apply a soap water ora liquid neutral  detergent onthe indoor unit connection  or outdoor unit connections by a soft  brush to check for leakage ofthe  connecting points of thpiping  If bubbles  come out  the pipes have leakage     2  Leak detector  Use the leak detector to check for leakage     CAUTION    A  Lo packed valve B  Hi packed valve  C and D are ends of indoor unit connection     NOTE  The illustrationis for explanation  purpose only  The actual orderof A  B C  D andE onthe machine may be slightly  different from the unit you purchased  The  actual shape shall prevail     Test running       Indoor unit     check point    Outdoor unit  check point                A  B C Dare points for one four type   A  B C D E are points for one five type     Fig 69    Perform test operation after completing gas leak check at the flare nut connections and    electrical safety check        Check thatall tubing and wiring have been properly connected      Check thatthe gas and liquid side service valves are fully open   1  Connect the power  press the ON OFF button onthe remote controller to turn the unit on   2  Use the MODE button to select COOL  HEAT  AUTO and FAN to check if all the functions    works well     3  When the amient temperature is too low lower than 17  C   the unit can
11.  CAUTION    1  This equipment must be earthed and installed with earth leakage current breaker  It may cause electrical  shock if grounding is not perfect     2  Do not install the unit at place where leakage of flammable gas may occur  In case gas leaks and  accumulates at surrounding of the unit  it may cause fire        3  Carry out drainage piping as mentioned in installation instructions  If drainage is not perfect  water  may enter the room and damage the furniture                 4  The appliance shall be installed in accordance with national wiring regulations        5  Do not operate your air conditioner in a wet room such as a bathroom or laundry room        6  An all pole disconnection device which has at least 3mm clearances in all poles   and have a  leakage current that may exceed 10mA  the residual current device  RCD  having a rated residual  operating current not exceeding 30mA  and disconnection must be incorporated in the fixed wiring   N in accordance with the wiring rules  J     2              1  Wall mounted type  Selecting installation place    INSTALLATION INSTRUCTIONS          More than 15cm    Read completely  then followstep by step     Indoor unit j       Do notexpose theindoor unitto heator steam  Moreen etn  e Select aplace where there are no obstacles    in front or around the unit     e Make sure that condensation drainage can  j More than 2 3m    More than 12cm      gt        be conveniently routed away      Do notinstall neara doorway   Ensur
12.  Drain hose       Left hand piping             m    Fig 9 Fig 10  Indoor unit Ponding box  Connective  BSL Pipe room  cable Z  4 a Connective  eet pipe    as    Wrapping belt  Drain hose    Fig 11    INSTALLATION INSTRUCTIONS       4  Indoor unit installation   1  Pass the piping through the hole in the  wall    2  Put the upper claw at the back of the  indoor unit on the upper hook of the  installation plate  move the indoor unit  from side to side to see that it is securely  hooked  see Fig 12     3  Piping can easily be made by lifting the  indoor unit with a cushioning material Fig 12  between the indoor unit and the wall    Get it out after finish piping     Upper hook       Floating prevention  support    4  Push the lower part of the indoor unit up    on the wall  then move the indoor unit  from side to side  up and down to check  if it is hooked securely       Number of connected  Indoor units that can  units 1 5units    be used in combina   tion    Compressor Stop time 3 min or more  stop start frequency    Voltage fluctuation   Within  10   of rated voltage    Power source Voltage drop during within  15   voltage start of rated voltage  within  3    of rated voltage          Interval unbalance                            1 drive 2 1 drive 3  1 drive 4 1 drive 5  Max  Length for allrooms 30m 45m 60m 75m  Max  Length for one indoor unit 20m 25m 30m 30m  Max  height different between   OU higherthan IU  10m 10m 10m 10m  indoor and outdoor unit OU lower than IU 15m 15m 1
13.  Fig 49 5     Hanging screw bolt     D  w Cat     www     Hanging bots      Supporting  angle steel          Fig 49 5    4 3 Wall Mounting Installation    A          D  Connecting point of  refrigerant pipe             Y_E  Connecting point of  refrigerant pipe   E  Liquid side                                                  Fig 49 6    1  Fix the hook with tapping screw onto the  wall   Referto Fig 49 7   2  Hang the indoor unit onthe hook        Y     Hook                  JN Tapping screw    Washer                 lt 6mm             Fig 49 7    4 4 Ceiling Installation                                                                                                      3      L  i   i     ia He  sU B O LJ  Hanging arm  Fig 49 8    1  Remove the side board and the grille    Refer to Fig 49 9   For 48000Btu h and  60000Btu h models  do notremove the                                  grille    L A    Ef  A    i Side board                         Grille                   Fig 49 9    INSTALLATION INSTRUCTIONS    2  Location the hanging arm onthe hanging  screw bolt   Refer to Fig 49 10   Prepare the mounting bolts on the unit    Refer to Fig 49 11                                E  E  S Screw nut   8 13mm  8 Washer  7 INDOOR UNIT  Hanging  screw bolt Mounting bolt  Hanging arm  Max 40mm   Fig 49 10 Fig 49 11    3  Hang the uniton the hanging arm by  sliding backward  Securely tighten the  mounting bolts on both sides    Refer to Fig 49 12     Hanging  Screw bolt      Hanging arm 
14.  PE  LN  L A  N  A  S  A  L B  N B  S B  LO O sO LO O SO LE NE sE   KEO    KKE o                                                                                                                         5 TENERE  Li  c  L2     se  L10  L20  S0  Lite  L2  sie   SaD A ap A GP GS GP ESTE                                                                     Lii2zs           i Li 2 S     Model B    o PESER    o KBREKERDIEDIDIEDIE P ORDERED DDD  L N    LA N A S A LG _NG  58  L  N  SC LO NO  s0   Sie   LN  L N  S LB  NG  56 LO NG SC LO NO  s0  RENG  RPK DK iS KBEBECIBIPEDIPIDE      _ KBIDIEEDIEREDIEPID       Lii2z2s                                                                                                                                                                                                                    TO B 0  Model D  B Se et ee ee a ee ee ee ee a    m  l    Magnetic ring not supplied optional part      Used to hitchto the connective cable of indoor  l    and outdoor units after installation      Ras ye eRe RLS RANE Od eS ee CET Se J    ELECTRICAL WORK       While connecting the wire of 24K model    While connecting the wire of 24K model only the terminals Acan be connected to the 24K indoor  unit at this time the terminals B can not be connected to any indoor unit as shown below        O       LCI NIC  S C  LD  ND  S D  LE  NEJ S E                                Fig 64    NOTE  When  EE  appeared inthe indoor unit display window    E9  appeared onthe   outdoor uni
15.  eee ener tee tee eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaeaaaaaaaaaaeeneenees 24  OUTDOOR unit Installation  fecs caste ie dee ceetisecies e ada danse e ea saasienedecns fu adeniduces ae ae senceacdeasenede 28    REFRIGERANT PIPE CONNECTION    Refrigerant pipe CONNECTION sisisi iurandi ea daian aa aane 29    ELECTRICAL WORK    Ed aa Eae d EEEE E A A EE E E O ERE A ENEE EE 30    AIR PURGING    Air purging  with VACUUM DUMP 22 22 26 scetdstetesapentes teeeneecehaelenenetue bandana suchsbbartanbee ran tieenepcetds lac eesteayaias 35  Safety and leakage  CheCk  secse iccs secescadcttesncectedoustaviesdeaeies cadens ongeed fats E ERAN EE EEES 36  TEST RUNNING   TESTI MING beiei eara aaa a E ayddgdewauanatasesubaunnennegenesauanenuecseanynausdecapanguacaneenicniies 37    Read This Manual    Inside you will find many helpful hints on how to install and test the air conditioner properly   All the illustrations and specifications in the manual are subject to change without prior notice for product  improvement  The actual shape should prevail     A CAUTION    Contact an authorised service technician for repair or maintenance of this unit    The appliance shall be installed in accordance with national wiring regulations    This appliance is not intended for use by persons including children  with reduced   physical  sensory or mental capabilities  or lack of experience and knowledge  unless   they have been given supervision or instruction concerning use of the appliance by a  person responsi
16.  table is for reference   Attention  Adopt PVC4O0 or bigger pipe to be the main pipe        Reference value of inner    Allowable maximum water flowrate                      PVC 40 31 730  PVC 50 40 1440  PVC 63 51 2760       PVC pipe diameter of pipe  I h  Remark   mm    it a5 20 eee For branch pipe   PVC 32 25 410       Could be used for    confluence pipe       e The horizontal pipe layout should avoid converse flow or bad flow     Drainage pipe         Branch pipe    Keep a certain degree         Water flow    Drainage pipe               Main pipe    Drainage pipe            Water flow  y    Branch pipe    Fig 30    Drain tee                 Water flow Water flow Water flow Water flow  Water flow   Water flow    water tlow  Water flow  Gas Gas       INSTALLATION INSTRUCTIONS   3  Water storage pipe setting       e If the indoor unit has high extra static pressure and without water pump to elevate the  condensate water  such as high extra static pressure duct unit  the water storage pipe  should be set to avoid converse flow or blow water phenomena             S    Plug G N    J Z    Indoor unit                         More than 50mm                         More than 25mm          4  Lifting pipe setting of indoor unit with water pump    e The length of lifting pipe should not exceed the pump head of indoor unit water pump    e Pump head of big four way cassette 750mm    e Pump head of compact four way cassette  500mm 9k  12k  18k units     e The drainage pipe should be se
17.  the hotspring     D  Factory where the voltage fluctuate greatly    E  In the car or in the cabin    F  In the kitchen or a place full of oil steam     G  There is strong electromagnetic wave    H  There is combustible gas or materials       There is much evaporating acid or alkaline gas    J  Other special areas     oe     e Pipe joint heat insulation   Remote controller Remote control air conditioner  Big washer Overhang indoor unit  Constriction bandage Binding insulation pipe    Water outlet joint  for cool heat type  P       Outdoor unit drainage  a Gasket  for cool heat type only  Outdoor unit drainage  open ee                         Indoor unit installation    Installation location    Enough room for installation and maintenance                                                                                                                    LLLLLLLLS f LL LLLLLLLSLSSSLLSLSSL SSS 4  Air outlet  a  lt 1000mm  gt    i   j  p  Direction A E    Airoutle   PUct Ji  P   ou 4  pi  gt 200mm  i     lt    _   _ gt    ae Air return box  lt 3m  Air return box Direction A ae       The ceiling is horizontal and it can afford the weight of the indoor unit      The air inlet and outlet are not impeded and does not affected by outdoor air too much     The air flow can reach every part of the room      The connecting pipe and drainpipe can be easily extracted out       There is no direct radiation from heat source             INSTALLATION INSTRUCTIONS        amp  Installation of unit 
18. 5m 15m  Max  height different between indoor units 10m 10m 10m 10m                         INSTALLATION INSTRUCTIONS       2  Four way cassette type  Attached fittings    Please check whether the following fittings are of full scope  If there are some attached fittings free  from use  please restore them carefully     1 Installation manual  2 Owner s manual  3  Remote controlle       5 Out let pipe sheath  6 Out let pipe Clasp     7 Drain joint     8  Installation paper board    C_e 9  Soundproof   insulation sheath    10  Seal ring  15  Mounting screw ST2 9 X 10 C H     2    om    Notes before installation Necessary room    i  2   3     Indoor unit installation  i   A  The existing ceiling  to be horizontal   a       If installing in a lonely building or at a high position      Please select the position of installation hooks    Decide the correct carry in path       Move this unit as originally packaged as possible  g  If the air conditioner is installed on a metal part        of the building  it must be electrically insulated  according to the relevant electrical code                    e t    Outlet Inlet Outlet     gt 2300    where it is hot and humid with frequent thunder  Ground  storm  lightning protection equipment is necessary     Install the main body    Please cut a quadrangular hole of 600 x 600mm  in the ceiling according to the shape of the y  installation paper board   Refer to Fig 15  amp  16  A  The center of the hole should be at the same  position of that 
19. Before using your air conditioner  please read  this manual carefully and keep it for future reference     INVERTER ONE TWO   ONE THREE   ONE  FOUR ONE FIVE SPLIT TYPE    ROOM AIR CONDITIONER    SAONA NLA     Please read this installation manual completely  before installing the product    If the power cord is damaged  replacement work  shall be performed by authorised personnel only   Installation work must be performed in accordance  with the national wiring Standards by authorised  personnel only    Contact an authorised service technician for  repair  maintenance or installation of this unit        CONTENTS  SAFETY PRECAUTIONS  W Ann  E E teeta corer Siete este vee A ap tes een eyed Stn es ere eed ee ee Ae ed 2  CUON ariaren ere iea adadni aada ER Eaa lige chats cuducecdialansuehyendpldpandens shgheee id EE 2    INSTALLATION INSTRUCTIONS    Selecting installation PlaC           ee eeeeecee eee eeeeeeeeeaee sea seaa eee rioen nen pi e e Oe EPEn R PiE ei 3  Wall mounted type ccccocdccedstaverscccecceivaaicsaevelae st bigevccnexsebderavsteestsceteetsiearddsaeeviaene E E ra EEEa ENET 3  ACCOSS  NIES  cuccicdiatldebobe dined opts a A E O EE E REA a ea a E aa e E O Oa 4  Four way Cassette  tyP  ou    seisatas eserin aa nan EA a E aaa a EEEn e ia irinae a 9  Duct   amp  Celing type sersrisiipiini ieee ear n E N EEE EE E N E EENE 15  Ceiling  and  FOOL ty PO ie aena aon raa aaa Ea aSa a a Ea a a a Sa aE a a e E Ta oaia aa 21  Floor and Standing type Console           eeeceeeeeeee
20. about 10cm     O    Downward declivity  lower than 1 100 VP30    Fig 50 9                                                 Au    m Drainage test    e Check whether the drain pipe is  unhindered    e New built house should have this test  done before paving the ceiling     5 6 Wiring Console        CAUTION    e The appliance shallbe installed inaccordance  with national wiring regualtions    e The airconditioner should use separate power  supply with rated voltage    e The external power supply to the air conditioner  should have ground wiring  which is linked to the  ground wiring ofthe indoor andoutdoor unit       The wiring work should be done by qualified  persons according to circuit drawing    e Anall pole disconnection device which has at  least 3mm separation distance in all pole and  a residual current device RCD with the rating  of above 10mA shall be incorporated in the fixed  wiring according to the national rule     e Be sure to locate the power wiring andthe  signal wring well to avoid cross disturbance    e Do not turnon the poweruntil you have  checked carefully after wiring     5 6 1 Connectthe cable    m The installation bearer of sensing  device rotatedto another side  andthen  takes off cover of electrical box   Take  off the electrical box if the capacity is  18000btu h as well as using network  function    Refer to Fig 50 10     Installation bearer  of sensing device       Fig 50 10    NOTE    All the pictures inthis manual are for  explanation purpose onl
21. arby condensate water discharge     e Before installing condensate water pipeline     determine its route and elevation to avoid    intersection with other pipelines and ensure    slope is straight     e In general  the supporter gap of the drainage    pipe horizontal pipe and vertical pipe is  respectively 1m 1 5m and 1 5m 2 0m      2  Drainage pipe selection       The drainage pipe diameter shall not small than the drain hose of indoor unit     Pump pipe clasp   the fittings     Fig 28    Le Ls Le       Lean over 1 50    LLLLL       Toolong distance       Gas bag                  e According to the water flowrate and drainage pipe slope to choose the suitable pipe  the    water flowrate is decided by the capacity of indoor unit     Capacity x1000Btu h     Water flowrate I h                             12 2 4  18 4  24 6  30 7  36 8  42 10  48 12  60 14             e According to the above table to calculate the total water flowrate for the confluence pipe    selection        INSTALLATION INSTRUCTIONS    For horizontal drainage pipe The following table is for reference   Attention  Adopt PVC40 or bigger pipe to be the main pipe                                   Reference value of inner   Allowable maximum water flowrate   PVC pipe diameter of pipe  l h  Remark   mm  Slope 1 50   Slope 1 100   PVC 25 20 39 27 For branch pipe  PVC 32 25 70 50  PVC 40 31 125 88 Could be used for  PVC 50 40 247 175 confluence pipe  PVC 63 51 473 334       For vertical drainage pipe The following
22. ble for their safety    Young children should be supervised to ensure that they do not play with the air conditioner   Do not operate your air conditioner in a wet room such as a bathroom or laundry room   Installation work must be performed in accordance with the national wiring standards by  authorised personnel only     SAFETY PRECAUTIONS          Read the follow SAFETY PRECAUTIONS carefully before installation    e Electrical work must be installed by a licensed electrician  Be sure to use the correct rating  of the power plug and main circuit forthe model to be installed    e Incorrect installation due to ignoring of the instruction will cause harm or damage   m The seriousness is classified by the following indications         A WARNING   This symbol indicates the possibility of death or serious injury        LA CAUTION   This symbol indicates the possibility of injury or damage to property  J       m The items to be followed are classified by the symbols             S Symbol with background white denotes item that is PROHIBITED from doing             a    WARNING  gt      1  Engage dealer or specialist for installation  If installation done by the user is defective  it will cause water  leakage  electrical shock or fire     2  Install according to this installation instructions strictly  If installation is defective  it will cause water  leakage  electrical shock or fire     3  Use the attached accessories parts and specified parts for installation  otherwise  it will 
23. cause the set to fall   water leakage  electrical shock or fire                 4  Install at a strong and firm location which is able to withstand the set   s weight  If the strength is not enough  or installation is not properly done  the set will drop and cause injury        5  For electrical work  follow the local national wiring standard  regulation and this installation instructions  An  independent circuit and single outlet must be used  If electrical circuit capacity is not enough or defect found  in electrical work  it will cause electrical shock or fire     6  Use the specified cable and connect tightly and clamp the cable so that no external force will be acted on  the terminal  If connection or fixing is not perfect  it will cause heat up or fire at the connection     7  Wiring routing must be properly arranged so that control board cover is fixed properly  If control board cover  is not fixed perfectly  it will cause heat up at connection point of terminal  fire or electrical shock              8  When carrying out piping connection  take care not to let air substances other than the specified  refrigerant go into refrigeration cycle  Otherwise  it will cause lower capacity  abnormal high pressure     in the refrigeration cycle  explosion and injury        9  Do not modify the length of the power supply cord or use of extension cord  and do not share the S  single outlet with other electrical appliances  Otherwise  it will cause fire or electrical shock        ZX
24. connection from a power supply shall be incorporated in the fixed  wiring and have an air gap contact separation of at least 3mm in each active phase     conductors   10  Before obtaining access to terminals  all supply circuits must be disconnected                    D    AIR PURGING       Air purging   Air and moisture inthe refrigerant system have undesirable effects as indicated below      Pressure inthe systemrises      Operating currentrises      Cooling or heating efficiency drops      Moisture inthe refrigerant circuit may freeze and block capillary tubing      Water may lead to corrosion of parts inthe refrigeration system    Therefore  the indoor unit and tubing between the indoor and outdoor unit must be leak tested  and evacuated to remove any noncondensables and moisture from the system     Air purging with vacuum pump   e Preparation  Check that each tube both liquid and gas side tubes  between the indoor and outdoor units  have been properly connected and all wiring forthe testrun has been completed  Remove  the service valve caps from both the gas and the liquid side on the outdoor unit  Note that  both the liquid and the gas side service valves onthe outdoor unit are kept closed at this  stage       Pipe length and refrigerant amount           Connective Air purging ca    pipe length method Additional amount of refrigerant to be charged  Use vacuum    Less than  65xN m pump        Use vacuum   Liquid side  66 35  More than  5XN m   pump  R410A   Total pipe le
25. ctive pipe installation  1  For the left hand and right hand piping   remove the pipe cover from the side panel   2  For the rear right hand and rear left hand  piping  install the piping as shown in Fig 10   3  Fix the end of the connective pipe   Refer  to Tightening Connection in REFRIGERANT  PIPING CONNECTION     4  Piping and wrapping  Bundle the tubing  connecting cable  and drain    hose with tape securely  evenly as shown in Fig 11     e Because the condensed water from rear of the  indoor unit is gathered in ponding box and is  piped out of room  Do not put anything else in  the box     CAUTION    e Connect the indoor unit first  then the  outdoor unit    e Do not allow the piping to let out from  the back of the indoor unt    e Be careful not to let the drain hoe slack    e Heat insulated both of the auxiliary piping    e Be sure that the drain hog is located at  the lowest side of the burdle  Locating  at the upper side can cawe drain pan  to overflow inside the unit       Never intercross nor intertwist the power  wire with any other wiring    e Run the drain hose sloped downward to  drain out the condensed water smoothly     INSTALLATION INSTRUCTIONS    Wall    Indoor A Outdoor         Fig 6    7 7 i  1  Do not put the end of    Do not block water flow by a rise  drain hose into water                             5 7mm                            Fig 7  A   Wa  Shield pipe i  ra 7 N                                                             AA Extension drainhose 
26. e thatthe space on the left and right Fig 1  of the unit is more than 12cm   Use astud finder to locate studs to prevent unnecessary damage to the wall   The indoor unit should be installed on the wall ata height of 2 3 metres or more from the floor   The indoor unit should be installed allowing a minimum clearance of 15cm from the ceiling   Any variations in pipe length will may require adjustment to refrigerant charge   There should not be any direct sunlight  Otherwise  the sun will fade the plastic cabinet and  affect its appearance  If unavoidable  sunlight prevention should be taken into consideration     Outdoor unit  More than 30cm  e If anawning is built over the outdoor unit to  prevent direct sunlight orrain exposure  More than 30cm  make sure that heat radiation from the  condenser is not restricted     e Ensure thatthe clearance around the back  of the unit is more than 30cm and left side is  more than 30cm  The front of the unit should  have more than 200cm of clearance and the  connection side  right side  should have more  than 60cm of clearance  Fig 2  e Do not place animals and plants in the path of the airinlet or outlet   e Take the air conditioner weight into account and select a place where noise and vibration  will not be anissue   e Select aplace sothat the warm air and noise from the air conditioner do not disturb neighbors     More than 60cm       More than 200cm    Rooftop installation        If the outdoor unitis installed on a roof structure  be s
27. ed  but the body mustinstall    wiring and transmission wiring at least 1 meter  away from televisionsand radios  This is to  prevent image interferenceand noise inthose  electrical appliances   Noise may be generated  depending on the conditions under which the  electric wave isgenerated  even if1 meter iskept      Y    vertically                         5 4 Install the connecting pipe   Console   Check whether the height drop between  the indoor unit and outdoor unit  the length  of refrigerant pipe  andthe number of the  bends meetthe following requirements              Capacity KBtu h  719 12 18 20 26 32 53       The max height drop 5m 10m                The length of refrigerant pipe  Less than 10m  Less than 20m                         The number of bends Less than 5m    Less than 5                         5 4 1 The procedure of connecting pipes     Hook A CAUTION    e All field piping mustbe provided by a licensed  refrigeration technician andmust comply with  the relevant localand national codes    Fig 50 3 e Do notlet air  dust  or other impurities fallin the    pipe system during the time of installation    e The connecting pipe should not be installed  until the indoor and outdoor units have been                      5 3 2 Install the main body fixed already     Fix the hook with tapping screw onto e Keep the connecting pipe dry  and do not let    the wall   Refer to Fig 50 4  moisture in during installation     e Execute heatinsulation work completely on    both s
28. essure on connecting  part of drainpipe      The gradient downwards of drain pipe should be  over 1 100  and do not bend the drain pipe    e Pull the drain pipe transversely within 20m  Please  install a supporter in case the drainpipe is very  long to prevent it from bending       Refer to the figures on the right for the installation  of pipes        Accessories installation instruction for duct  Duct design    Make the duct as short as possible due to the  low static pressure  nearly 0 pa  of this unit     Fix installation board   Fix the installation board on duct outlet with  the bolts in accessories  If the bolt is  self provided  the length of bolt should be  appropriate and make sure not to damage the  inside of unit  See Fig 47    Duct installation   Fix the duct oninstallation board with rivet   See Fig 48   NOTE        Lean Downward over 1 100    Fig 44    Bend x  Fig 45    As long as possible  10cm     Supporting Unit    Say     Lean Downward  over 1 100    Fig 46    VP30       1 Do notlet the indoor unit bear the weight of duct     2 For convenient maintenance  installthe duct  at the place whereit is easy todo removing    3 In case doing installationin meeting room or  such places  please equip the interior with  liner and muffler        a Aiet  fix the duct                 norm  N              Air oulei    4 These accessories are optional  Please contact    the service for other requirement     Accessories    Fig 48          Name Qty  Outline specification Func
29. hat the air is entering Operation noise  of the vacuum pump changes and a Low pressure valve  compound meter indicates 0 instead of minus   5  After the evacuation is complete  fully close  the handle Lo of the manifold valve and stop  the operation of the vacuum pump  Make Fig 67  evacuation for 15 minutes or more and check  that the compound meter indicates   76cmHg   1x10  Pa    6  Turn the stem of the packed valve B about  45   counterclockwise for 6 7 seconds after  the gas coming out  then tighten the flare nut  again  Make sure the pressure display in the  pressure indicator is a little higher than the  atmosphere pressure   7  Remove the charge hose from the Low  pressure charge hose   8  Fully open the packed valve stems B and A   9  Securely tighten the cap of the packed valve     Vacuum pump     lt              Safety and leakage check     Electrical safety check   Perform the electric safe check after   completing installation    1  Insulated resistance Indoor unit   r 4 check point  The insulated resistance must be more than 2MQ    2  Grounding work  After finishing grounding work  measure the Outdoor unit___      __ A a  grounding resistance by visual detection and  grounding resistance tester  Make sure the  grounding resistance is less than 42     3  Electrical leakage check  performing during    test running     During test operation after finishing installation   the serviceman can use the electroprobe and  multimeter to perform the electrical leakage  check
30. hed seal sponge as per the indicating plac   side rail        pin    the following fig  and then change the mounting positions of  air return panel and air return flange      Air return flange                         When install the filter mesh  please plug it into flange inclined 4   from air return opening  and then push up              The installation has finish  upon filter mesh which fixing  blocks have been insert to the flange positional holes                 NOTE       All the figures in this manual are for explanation purpose only  They may be slightly different from the air    conditioner you purchased  The actual unit shall prevail              INSTALLATION INSTRUCTIONS       Drainpipe installation    1  Indoor unit drainpipe installation O__   x    Piping  insulation material                x Fig 42  Piping Hard PVC pipe    Insulation material  Cellular polyethylene  thicker than 6mm    Drainage       No space                     See Fig 42    Heat insulation Main unit  material  Seal the  insulation material          Heat insulation                 e Please do heat insulation on piping joint   e Bind the contact insulation part between the  amp   unit and installation location with bandage   Fig 43    INSTALLATION INSTRUCTIONS    CAUTION       The drain pipe as well as the connection part of  indoor unit must be heat insulated  or condensate  will occur    e Please connect the pipe with horny PVC bond  and make sure there is no leakage    e Do not impose the pr
31. ides of the gas piping and the liquid  piping  Otherwise  this can sometimes result  in water leakage        INSTALLATION INSTRUCTIONS       1  Drilla hole in the wall  suitable just forthe  size of the wall conduit   then set onthe  fittings suchas the wall conduit and its  cover    2  Bind the connecting pipe and the cables  together tightly with binding tapes  Pass  the bound connecting pipe through the  wall conduct from outside  Be careful of the  pipe allocation to do on damage to the  tubing    3  Connect the pipes  Refer to  How to  Connect the pipes  for details    4  Expelthe airwith avacuum pump  Refer  to  Howto expel the air with a vacuum  pump  for details    5  openthe stop values ofthe outdoor unit to  make the refrigerant pipe connecting the  indoor unit with the outdoor unitin fluent  flow    6  Check the leakage  Check all the joints  with the leak detector or soap water    7  Cover the joints of the connecting pipe  with the soundproof  insulating sheath   fittings   and bind it well with the tapes to  prevent leakage     A CAUTION   Be sure to with insulating materials cover all  the exposed parts of the flare pipe joints and  refrigerant pipe on the liquid side and the  gas side  Ensure that thereis no gap between  them  Incomplete insulation may cause water  condensation     How to take indoor unit apart to connect   the pipes   1  Open the front panel   e Slide the two stoppers on the left and right  sides inword until they click  See Fig 50 6         
32. indoor unit and measure Gradienter  the level degree of unit with a gradienter      e Fasten and fix the upside nut    Hanging screw bolt    Nut  upside   Washer  upside      Installation ear nn Fig 39                 Fasten the nut    Washer  underside   Nut undersidej    Fig 38    The position of hanging bolts       Dimension and air outlet size    INSTALLATION INSTRUCTIONS                                                                                                                                                                                                                                                                            Unit  mm    f    1 Po oy  of J A A    Fel HO  d  ale  aa _      E F D  A C  Air inlet size  Air filter  Position size of descensional ventilation opening  F o            e Ig  is  5 P Air filter  el  s     g I    Electric control box  Size of mounted hook  Electric control box  Gy  cy  O    5   g j  L  Fig 40    INSTALLATION INSTRUCTIONS                                                                                   Size of  Outline dimension Air outlet openingsize Air return opening size mounted lug  A B C D E F G H l J K L M    lt 12000Btuh  700  210  635  570  65   493  35   119  595  200  80  740  350    gt 12000Btwh  920  210  635  570  65   713  35   119  815  200  80   960  350   How to adjust the air inlet direction   From rear side to under side     1  Take off ventilation panel and flange  cut off the staples at 2  Stick the attac
33. l  5  Whenlifting the unit   always use  aA protectors to prevent belt damage and  pay attention to the position ofthe  z omersmana         1   unit   s centre of gravity   ensataton manual           1   5 3 Indoor Unit Installation Console     5 3 1 Installation place    Remote controller  holder                               Cautions onremote controller installation    The indoor unit should be installedin a  location that meets the following  requirements    e There is enough room for installation and  maintenance   Refer to Fig 50 2  amp  Fig 50 3   The outlet and the inlet are not impeded   and the influence of external airis the    e Never throw or beatthe controller    e Before installation  operate the remote  controller to determine its location ina  reception range       Keep the remote controller at least 1m apart  from the nearest TV set or stereo equipment    it is necessary to prevent image    disturbances or noise interferences     ae PERTEN A EE A     Do notinstall the remote controllerin a place oom g    exposed to direct sunlightor closeto a  heating source  such as a stove    e Note thatthe positive and negative poles  are right positions when loading batteries     e The connecting pipe and drainpipe could  be extracted out easily   There is no direct radiation from heaters           INSTALLATION INSTRUCTIONS       A CAUTION   Hang the indoor unit on the hook    The bottom of body can touch with floor  Keep indoor unit  outdoor unit  power supply or suspend
34. nd correctly  orthe  air conditioner could notrun normally     NOTE     The cable size and the current of thefuse or  switch are determined by the maximum current  indicated on the nameplate which located on the  side panel of the unit  Please refer to the  nameplate before selecting the cable  fuse and  switch  Please refering to the above tables and  choosing the proper wire size under the local  electrical requirements     Connect the cable to the outdoor unit    1  Remove the electrical control board cover  from the outdoor unit by loosening the screw  as shown in Fig 61   2  Connect the connective cables to the  terminals as identified with their respective  matched numbers on the terminal block of  indoor and outdoor units    3  Secure the cable onto the control board with  the cord clamp    4  To prevent the ingress of water  from a loop  of the connective cable as illustrated in the  installation diagram of indoor and outdoor  units    5  Insulate unused cords  conductors  with  PVC tape Process them so they do not  touch any electrical or metal parts        cautions    Make sure to connect the indoor unit  A B C  D   E  tothe Hiand Lovalve andterminals of signal  wires A  B C  D  E  of outdoor unitas identified  with their respective matched connection   Wrong wiring connections may cause some  electrical parts to malfunction     Minimum norminal cross sectional area  of conductors                       Rated current ofappliance Nominal cross sectional   A  area  mm 
35. ndoor and  outdoor unit  then put them on pipe tube  having completed burr removal  not possible  to putthem on after flaring work     D  Flaring work    Firmly hold copper pipein adie inthe  dimension shownin the table below                             Outer diam  A mm    mm  Max  Min   p 6 35 1 3 0 7  o 9 52 1 6 1 0     12 7 1 8 1 0          Fig 55  Flare nut  Copper tube  Fig 56          Clamp hahdle Red arrow mark    Fig 57    ELECTRICAL WORK       Tightening Connection     I WL  e Align the center of the pipes     Wna VSS    e Sufficiently tighten the flare    nut with fingers  and then tighten Indoor unit tubing    Flare nut Pipings    it with a spanner and torque wrench                                        as shown in Fig 58  amp  59 Fig 58  Outer   Tightening   Additional tightening  diam    torque N cm  torque N cm   1500 1600  6 35  153kgf cm   163kgf cm   2500 2600  9 52    255kgf cm   265kgf cm   3500 3600  12 7    357kgf cm   367kgf cm   Caution  e    Excessive torque can break nut  depending on installation conditions     When select a 24K indoor unit  When selecta 24K indoor unit the manifold  assembly  not supplied  should be purchased  and installed together    Installation method when connecting the pipe   connect the liquid pipe  thin pipe  and gas pipe   thick pipe  of the manifold assembly to the  high pressure valve and low pressure valve of  the outdoor unit as identified with their  respective matched numbers A  amp  B as shown  below                
36. ngth   5xN x15g m  N 2 3 4or 5   Liquid side  69 52  R410A   Total pipe length   5xN x30g m  N 2 3 4or 5                      When relocate the unit to another place                                                                    perform evacuation using vacuum pump  Refrigerant     Make sure the refrigerant added into the air Outdoor Herta  conditioner is liquid form in any case  unit a Gas side _ C  Liquid sid  Ps iquid side _ D  i i    B  Caution in handling te packed valve Packed valve Harunin    Open the valve stem until it hits against the  stopper  Do not try to open it further  Fig 65  e Securely tighten the valve stem cap with a  spanner or the like   e Valve stem cap tightening torque  See Flare nut  Tightening torque table in previous page     Stopper  Cap   l  Valve body   mss  Valve stem  Fig 66    AIR PURGING       When Using the Vacuum Pump    For method of using a manifold valve  refer   to its operation manual   Manifold valve   1  Completely tighten the flare nuts  A  B  C  D  Compound meter   Pressure gauge  connect the manifold valve charge hose to a            charge port of the low pressure valve on the  76cmHg 7   gas pipe side  NL 7     Handle Hi  2  Connect the charge hose connection to the Flandle Lo   vacuum pump  Charge hose            Charge hose    3  Fully open the handle Lo of the manifold valve   4  Operate the vacuum pump to evacuate  After  starting evacuation  slightly loose theflare nut  of the Lo valve on the gas pipe side and  check t
37. not be controlled by  the remote controller to run at cooling mode  manual operation can be taken  Manual  operation is used only when the remote controlleris disable or maintenance necessary     sound     Hold the panel sides and liftthe panel up to an angle until itremains fixed with aclicking    Press the Manual control button to select the AUTO or COOL  the unit will operate under    Forced AUTO or COOL mode see User Manual for details    4  Thetest operation should last about 30 minutes                      TN    Manual control  Button    Fig 70    D                   Jh     Eam                                                 Manual control  button      O AUTO COOLI             The design and specifications are subject to change without prior notice for product  improvement  Consult with the sales agency or manufacturer for details     CS464 I  202000191053  20131225    
38. nst the wall  or on bulgy objects   e Never crash or strike it      1  Remove the inlet grid     a  Slide two grid switches toward the middle  at the same time  and then pull them up    Refer to Fig 21    b  Draw the grid up to an angle of about 30     and remove it   Refer to Fig 22           INSTALLATION INSTRUCTIONS        2  Install the panel   a  Align the swing motor on the panel to the water  receiver of the body properly   Refer to Fig 23    b  Hang the four fixed rope of the main body to the  installation cover and the other three covers of  the swing motor   Refer to Fig 23         CAUTIONS     The installation cover of the swing motor must sink  into the corresponding water receiver    c  Install the panel on the main body with bolt  M5 x 16   and washer   Refer to Fig 23    d  Adjust the four panel hook screws to keep the panel  horizontal  and screw them up to the ceiling evenly    e  Regulate the panel slightly to fit the panel s center  to the center of the ceiling s opening  Guarantee  that hooks of four corners are fixed well    f  Keep fastening the screws under the panel hooks   until the thickness of the sponge between the body     and the panel s outlet has been reduced to about     4 6mm  The edge of the panel should contact with  the ceiling well   Refer to Fig 24  Malfunction  described in Fig 25 can be caused by inappropriate  tightness the screw  If the gap between the panel  and ceiling still exists after fastening the screws  the  height of the ind
39. nstructions  consult the construction  personnels for the specific procedures        The size of the ceiling to be handled    do  keep the ceiling flat  Consolidate the roof  beam for possible vibration        Cut off the roof beam        Strengthen the place cut off  and consolidate  the roof beam    e Carry out the pipe and line operation in the  ceiling after finishing the installation of the  mainbody While choosing where to start the  operation  determine the direction of the pipes  to be drawn out  Especially in case there is a  ceiling  position the refrigerant pipes  drain  pipes  indoor  amp  outdoor lines to the connection  places before hanging up the machine    e The installation of hanging screw bolts     2  Wooden construction  Put the square timber traversely over the  roof beam  then install the hanging screw  bolts   Referto Fig 49 2     Timber over the beam    g g  LO  l     Roof beam  y                         Ceiling                            7    Hanging screw bolts    Fig 49 2    3  New concrete bricks  Inlaying or embedding the screw bolts    Refer to Fig 49 3     Ww A     Blade shape insertion   Slide insertion     Fig 49 3    4  For original concrete bricks  Use embedding screw bold  crock  and stick harness  Referto Fig 49 4         A         Steel bar    ES 25                   1 Embedding screw bolt     Pipe hanging and embedding screw bolt     Fig 49 4    5  Steel roof beam structre  Install and use directly the supporting  angle steel   Refer to
40. oe e A sasetonie   NOTE  Pipe size differ from appliance to appliance  P  Tomeet different pipe size requirement  sometimes Optional part  the pipe connections need the transfer connector  1 5 pieces for outdoor  to install on the outdoor unit    unit  depending on  models   Magnetic ring Opti t  11  Hitch iton the connective cable between indoor aa par bl  unit and outdoor unitafter installation    one piece one cable   Cord protection rubber ring    12  If the cord clamp can not fasten the cord for the small size  of the cord  please use the cord protection rubber ring ton some models    supplied with accessories  to wrap on the cord  then fix it  with the cord clamp                     Note  Except the above parts provided  the other parts needed during installation you must purchase     O    INSTALLATION INSTRUCTIONS    m    More than  3n a       ofp  Remote        controller    Remote  controller    j    LL          iiil     IN  ni       Loopa  connective             One Three       One Four      One Five       controller       Fig 3       cautions    e This illustration is for explanation purposes only   The actual shape of your air condtioner may be  slightly different    e Copper lines must be insulated independently    CAUTION      Use astud finder to locate studs to prevent  unnecessary damage to the wall    e A minimum piperun of 3 metres is required  to minimise vibration  amp  excessive noise    e Two ofthe A  Band Cdirections should be   free from obstructions  
41. of the air conditioner body   Determine the lengths and outlets of the conn   ecting pipe  drain pipe and cables    To balance the ceiing and to avoid vibration   please enforce the ceiling when necessary           according to the hook holes on the installation  board    Drill four holes of 612mm  50 55mm deep at the  selected positions on the ceiling  Then embed  the expansible hooks fittings     Face the concave side of the installation hooks  toward the expansible hooks  Determine the  length of the installation hooks from the height  of ceiling  then cut off the unnecessary part    If the ceiling is extremely high  please determine  the length of the installation hook according to  facts    Cut the installation hook open in the middle  position  then use apropriate length of reinforcing  rod   12  to weld together         523 Hook location        545 Hook location     570 Body          Unit  mm        647 Panel     Fig 15    INSTALLATION INSTRUCTIONS                               The length could be calculated from Fig 17  S   Length 210 L in general  L is half of the whole LLL LL LLL ED ihe   length of the installation hook    Bad     c  Please adjust the hexangular nuts on the four Nut ms re  installation hooks evenly  to ensure the balance   2  of the body  z a    e Use the transparent hose filled with water to check sel    eon Neare   the level of the main body from the four sides or Fig  16    diagonal line direction  the lever indicator also  can check the lever fr
42. om four sides of the main  body   Refer to Fig 18    e  f the drainpipe is awry  leakage will be caused  by the malfunction of the water level switch    e Adjust the position to ensure the gaps between  the body and the four sides of ceiling are even    e The body s lower part should sink into the ceiling  for 10 12mm  Refer to Fig 17   E   e Locate the air conditioner firmly by wrenching the Fig  17  nuts after having adjusted the body s position well          H ceiling height     New built houses and ceilings   a  In the case of new built house  the hook can be  embedded in advance  refer to the A b mentioned  above   But it should be strong enough to bear the                                      indoor unit and will not become loose because of Cine ee fer   concrete shrinking  trans parent pipe indicator  b  After installing the body  please fasten the install    ation paper board onto the air conditioner with bolts Fig 18 Fig 19    M5 X 16  to determine in advance the sizes and l   positions of the hole opening on ceiling  Please Fresh air intake  965  _S2ttralhole    first guarantee the flatness and horizontal of ceiling   when installing it  Refer to the A a mentioned Fixing hole   above for others  tee   CP  iV Hook hole  c  Refer to the A c mentioned above for installation    fe  d  Remove the installation paper board  Screw M516    Accessory J l i Installation    paper board    2  Install The Panel  CAUTIONS Fig 20  e Never put the panel face down on floor or    agai
43. oor unit should be modified again   You can modify the height of the indoor unit through  the openings on the panel s four corners  if the lift of  the indoor unit and the drainpipe is not influenced   refer to Fig 26 right       3  Hang the air in grid to the panel  then connect  the lead terminator of the swing motor and that  of the control box with corresponding terminators  on the body respectively     4  Relocate the air in grid in the procedure of  reversed order  install the air in grid      3  The installation of ventilation motor and  ventilation pipe  if necessary   a  Using a tool to knock off the pre punching hole    Refer to Fig 27     b  Four screw hole reserved for installation    Refer to Fig 27      _Four screw hole _                Steel rope                                      Please opdrate according  to the direction of the arrow           or it can not be disassembled  when it is necessary              Body    Inlet air          Panel sealing foam    Ceiling Panel foam2  a Sey    Panel foam       Outlet air Air plate Panel foam1    Fig 24                Hexagon nut  Horizontal adjust ment           pre punching hole                                                                                  INSTALLATION INSTRUCTIONS        4  water pump drainage    The maximum lifting height is 750mm     3  Drainage pipe installation     1  Installation principle  e Ensure at least 1 100 slope of the drainage    pipe     e Adopt suitable pipe diameter   e Adopt ne
44. t digital display at the same time   It indicates the wrong connection of 24K   unit It may be caused by the following conditions    1 The terminals B is connected to any indoor unit When the terminals Ais already  connected to 24K indoor unit    2 Any one terminal of B C D E is connected to 24K indoor unit     A CAUTION      After the confirmation of the above conditions  prepare the wiring as follows    1  Never fail to have an individual power circuit specifically for the air conditioner  As for  the method of wiring  be guided by the circuit diagram posted on the inside of control  cover    2  The screw which fasten the wiring in the casing of electrical fittings are liable to come  loose from vibrations to which the unit is subjected during the course of  transportation  Check them and make sure that they are all tightly fastened   If they  are loose  it could cause burn out of the wires     3  Specification of power source    4  Confirm that electrical capacity is sufficient    5  See to that the starting voltage is maintained at more than 90 percent of the rated  voltage marked on the name plate    6  Confirm that the cable thickness is as specified in the power source specification    7  Always install an earth leakage circuit breaker in a wet or moist area    8  The following would be caused by voltage drop    Vibration of a magnetic switch  which will damage the contact point  fuse breaking  disturbance of the  normal function of the overload    9  The means for dis
45. t down inclined after the lifting pipe immediately to avoid  wrong operation of water level swithch    e Refer the following picture for installation reference                                   Water storage pipe             Fig 31           Hanger    Down incline pipe    A Length of horizontal pipe  lt  150mm  B  Lift height  lt  the pump head of water pump    Flexible pipe  lt  300mm       Fig 32     5  Blowhole setting    e For the concentrated drainage pipe system  there should design a blowhole at the highest  point of main pipe to ensure the condensate water discharge smoothly   The air outlet shall face down to prevent dirt entering pipe   Each indoor system should be installed it   The installation should be considering the convenience for future cleaning     Blowhole                      Indoor unit  Indoor unit                Plug Plug    Ny                                                 INSTALLATION INSTRUCTIONS       3  Duct  amp  Ceiling type    Installation precautions   1  Determine the moving route    2  Move the unit in original state    3  Make sure to do electric insulation according to relevant electric standard  in case the unit is installed on metal part of building    4  Please keep away from the following places  or malfunction may be caused    if unavoidable  please consult the professionals     A  There is mineral oil like the oil of cutting machine    B  There is much salty air   Near the coast    C  There is caustic gas such as sulfuric gas   Near
46. tion  Duct installation f  board 8 Connecting duct       Fixation bolt  fixing    installation board  8 ST3 9X 10 F H             Fixing duct  installation board          20     INSTALLATION INSTRUCTIONS  4  Ceiling and Floor type    4 1 Accessories  Name of  Accessories  omessa ts   O  seoran   freer              Remote Controller  amp  Its Frame   on some models     Hook 2 For wall mounting    3  Mounting screw   ST2 9x10 C H     4    4  Alkaline dry batteries AM4     Q ty  1  1  1       Cautions on remote controller installation    e Never throw or beat the controller    e Before installation operate the remote  controller to determine its location in a  reception range    Mounting screw B   e Keep the remote controller at least 1m apart ST2 9x10 C H  from thenearest TV set or stereo equipment  SN   It is necessary to prevent image disturbances i LD   oo       or noise interferences       Do not install the remote controller in a place       exposed to direct sunlight or close to a     heating source  such as a stove     Remote controller  Note that the positive and negative poles Remote controller holder    are in right positions when loading batteries     Fig 49 1    INSTALLATION INSTRUCTIONS    4 2 Indoor unit installation    1  Installing   10 hanging screw bolts   4 bolts     e Please refer to the following figure for the  distance measurement between the screw  bolts    e Please install with  10 hanging screw bolts    e The handling to the ceiling varies from the  co
47. ure to level the unit    Ensure the roof structure and anchoring method are adequate for the unit location   Consult local codes regarding rooftop mounting    If the outdoor unitis installed on roof structures or external walls  this may result in  excessive noise and vibration  and may also be classed asa non serviceable installation     INSTALLATION INSTRUCTIONS       Tools needed    for installation        Level gauge  Screwdriver    Electric drill  Hole core drill    65mm   Flaring toolset    Vacuum pump    Gauge manifold  Users manual    Specified torque wrenches  1 8kgf m  4 2kgf m  Thermometer  5 5kgf m  6 6kgf m different depending on model No   Multimeter  Spanner  half union  Pipe cutter    Hexagonal wrench  4mm     Gas leak detector       Measuring tape                                                                      Accessories  Number Name of Accessories Q    ty one unit  1 Installation Plate 1  5 8  2 Plastic Expansion Sheath  depending on models   5 8  3 Self tapping Screw AST3 9X25  depending on models   Connecting   Liquid side 6 35  pipe  amp  9 52 Parts you must purchase  4 Assembly    9 52 Consult the technician  Gas side b127 for the proper size   P 15 9  5 Remote controller 1  6 Self tapping Screw B ST2 9X10 Optional 2  7 Remote controller holder parts 1  8 Seal  for cooling amp  heating models only  1  9 Drain Joint  for cooling amp  heating models only  1  10 Transfer connector Packed with the indoor unit or l  outdoor unit  depending on models   f
48. y  They may be  slightly different from the air conditioner  you purchased depend on model   The  actual shape shall prevail     INSTALLATION INSTRUCTIONS       Outdoor unit installation  Outdoor installation precaution       Install the outdoor unit on a rigid base to  prevent increasing noise level and vibration    e Determine the air outlet direction where the   discharged air is not blocked  In the case that   the installation place is exposed to strong wind  such as a seaside  make sure the fan operating  properly by putting the unit lengthwise along the  wall or using a dust or shield plates    Specially in windy area  install the unit to prev    ent the admission of wind  If need suspending   installation  the installation bracket should  accord with technique requirement in the  installation bracket diagram    e The installation wall should be solid brick   concrete or the same intensity construction  or  actions to reinforce  damping supporting should  be taken  The connection between bracket and  wall  bracket and the air conditioner should be  firm  stable and reliable    e Be sure there is no obstacle which block  radiating air     Settlement of outdoor unit      Anchor the outdoor unit with  a bolt and nut  10 or  8 tightly  and horizontally on a concrete  or rigid mount                       Outdoorunit dimension   Mountingdimensions   mm L1xHxW1   Tommy wamm   760x590x285 530 290  845x700x320 560 335  900x860x315 590 333  990x965x345 624 366                    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Operação e Manutenção  iSeries Industrial Videoscope (Technical Borescope) Data Sheet  BdA frc150 franz 5 km oG.FH10  Multiquip MVH406GH User's Manual  EPSOLAR Tracer-3215RN - Ecologie-Shop  METRATESTER 4 et 5 Appareils de contrôle DIN VDE 0701 et 0702  Bedienungsanleitung  Art.-Nr. 1.0203.01  Ingestion Tool User Manual - ics-forth    Copyright © All rights reserved. 