Home
        Dual OCU DP - Optimum Data Inc.
         Contents
1.   OCU the DP  3 PORT TEST    PORT    1 OCU DP                4  To select  press ENTER              3 10 Dual OCU DP Option Module and Plug on Board User Manual 61200230L1 1    Chapter 3  Operation       LOOPBACK    This item activates the loopback function on the OCU DP module     On the OCU DP  the CSU loopback initiates a sealing current rever   sal  Upon detecting this reversal  the DDS CSU  connected to the  OCU DP over a 4 wire loop  should loop data back toward the NI     The OCU loopback loops the data mapped to the OCU DP back to   ward the network interface of the controller  Using the loopback in  conjunction with an external BERT driving the Network Interface  will exercise the entire data path from the Network Interface  NI   through the OCU DP option module and back out the NI  See Fig   ure 3 2        T1                                                 TSU 100  OCU DP   DSU CSU    Network Interface                               Ht    NI  tt    4wire DBS   D     Controller  aA  OCU CSU                   Figure 3 2  Diagram of Loopbacks    To deactivate the loopback  go to the port test submenu and select  OFF        61200230L1 1 Dual OCU DP Option Module and Plug on Board User Manual 3 11    Chapter 3  Operation          3 12 Dual OCU DP Option Module and Plug on Board User Manual 61200230L1 1    Append Failure Messages    FAILURE MESSAGES AT POWER UP    The following messages indicate a probable part failure on the    OCU DP Module   EPROM   EPROM ERROR  SRAM   
2.   Placement of the Option  Module 2 2   Power Connection 2 2   Power Up Testing and Initializa   tion 2 5    S    Sealing Current 1 3   Signal Format 1 3   SRAM  failure message A 1   Static RAM ERROR  failure mes   sage A 1    T    Tests 1 3   TSU 100 Main Menu Tree 3 2  TX Output Amplitude 1 3  TX RX Source Impedance 1 3    Ww    Warranty And Customer Service 2     5  Wiring 2 3  2 4       Index 2 Dual OCU DP Option Module and Plug on Board User Manual 61200230L1 1    Product Support Information    Presales Inquiries and Applications Support  Please contact your local distributor  ADTRAN Applications Engineering  or ADTRAN  Sales     Applications Engineering  800  615 1176  Sales  800  827 0807    Post Sale Support  Please contact your local distributor first  If your local distributor cannot help  please con   tact ADTRAN Technical Support and have the unit serial number available     Technical Support  888  4ADTRAN    Repair and Return   If ADTRAN Technical Support determines that a repair is needed  Technical Support will  coordinate with theCustomer and Product Service  CaPS  department to issue an RMA  number  For information regarding equipment currently in house or possible fees associ   ated with repair  contact CaPS directly at the following number     CaPS Department  256  963 8722    Identify the RMA number clearly on the package  below address   and return to the follow   ing address     ADTRAN  Inc    CaPS Department   6767 Old Madison Pike  Progress Center  Bu
3.   data    TXLEVEL   Setsthe Transmit Signal out of the OCU DP to either Nor   mal or Attenuated  For short line lengths it may be neces   sary to attenuate the transmit signal if the signal is large  enough to saturate the DSU  CSU equipment being used   Choices    NORMAL or REDUCED 10dB  3 6 Dual OCU DP Option Module and Plug on Board User Manual 61200230L1 1       Chapter 3  Operation       3 FACT RESTORE Submenu of 3 UTIL    This menu item is used to restore the factory default setting for all  OCU DP option module parameters     Operation    Follow the standard operating procedure to access the 3 UTIL menu             items   Step Action Result  1  Place the cursor on  3 FACT RESTORE   2  Press ENTER  The unit returns to the open     ing main menu with all fac   tory preset defaults are  restored                       61200230L1 1 Dual OCU DP Option Module and Plug on Board User Manual 3 7    Chapter 3  Operation       X PORT UTILITY Submenu of 3 UTIL    The X PORT UTILITY menu item is primarily used to access the dis   play of the current software information for each port installed in  the unit  This information is required when requesting assistance  from ADTRAN customer service or when updates are needed     Operation    Follow standard operating procedure to access the 3JUTIL menu                   items   Step Action Result  1  Place the cursor on  X  PORT UTILITY   2  Press ENTER  The first available port dis   plays   3  Use the up and  down scroll keys to  identi
4.  2  Installation       Wiring  The Dual OCU DP has two connectors for a DDS interface       Connector Type 8 pin  modular    PN  AMP  555164 1    Table 2  1  Pinout for Eight Position Modular Jack Interface       Pin Name Description       1 TIPRX RECEIVE DATA FROM THE DSU       2 RINGRX   RECEIVE DATA FROM THE DSU  34 5 6   UNUSED          7 TIPTX SEND DATA TOWARD THE DSU                8 RING TX SEND DATA TOWARD THE DSU             2 4    Dual OCU DP Option Module and Plug on Board User Manual 61200230L1 1    Chapter 2  Installation       Power Up Testing and Initialization    The Dual OCU DP option module executes a self test during the  power up sequence  as described in the TSU Multiplexer User Man   ual  No initialization input is required  Automatically  upon power   up  any previously configured setting for the Dual OCU DP is re   stored     When the self testing is complete and the configuration is success   fully restored  it will be indicated by the illumination of the green   OK  LED in the MODULE group on the front panel   See the sec   tion Front Panel Operation in the TSU Multiplexer User Manual      If the Dual OCU DP module fails one or more of the self tests  a mes   sage is displayed on the front panel during power up   See the sec   tion Power Up Testing and Initialization in the TSU Multiplexer User  Manual      Specific failures of the Dual OCU DP module are shown in Appendix  A  Failure Messages on page A 1  If any alarms are detected during  operation 
5.  connectors  This allows a  plug on  card to be added  to the Dual OCU DP module  The PORT X 3 X 4 indication is  linked to the port numbering philosophy of the TSU 100 product  family  The X represents the slot number  and the  3 indicates the  port number  For the TSU 100 application  there is only one option  slot  Therefore  the port designation for the Dual OCU DP port will  be 1 2 1 3  If added  the plug on card port designation would be 1 3   These port numbers will appear in the front panel LCD menu dis     plays        1 4 Dual OCU DP Option Module and Plug on Board User Manual 61200230L1 1    Chapter  Installation    UNPACK  amp  INSPECT    Carefully inspect the Dual OCU DP module for any shipping dam   ages  If damage is suspected  file a claim immediately with the carri   er and then contact ADTRAN customer service  If possible  keep the  original shipping container for use in shipping the Dual OCU DP  Module back for repair or for verification of damage during ship   ment     ADTRAN Shipments Include    The Dual OCU DP Option Module      The Dual OCU DP Option Module User Manual  To be inserted  into main TSU User Manual     Customer Provides      Cable for connection to DSU CSU       61200230L1 1 Dual OCU DP Option Module and Plug on Board User Manual 2 1    Chapter 2  Installation       Installing the Option Module    The Dual OCU DP Option Module  PN1200 230L1  is hot replaceable and  can be installed in the TSU product with the power On     NOTE    Placement 
6.  the red    ALARM    LED in the MODULE group will illu   minate on the front panel     Warranty and Customer Service    ADTRAN will replace or repair this product within five years from  the date of shipment if it does not meet its published specifications  or fails while in service  For detailed warranty  repair and return in   formation refer to the ADTRAN Equipment Warranty  Repair and  Return Policy Procedure in the TSU Multiplexer User Manual     Return Material Authorization  RMA  is required prior to returning  equipment to ADTRAN     ForService  RMA requests  or more information  see the inside back  page of this manual        61200230L1 1 Dual OCU DP Option Module and Plug on Board User Manual 2 5    Chapter 2  Installation          2 6 Dual OCU DP Option Module and Plug on Board User Manual 61200230L1 1    Chapter 3 Operation    OPERATION OVERVIEW    The OCU DP module is controlled as part of the TSU multiplexer us   ing the same methods as described in the TSU Multiplexer User Man   ual     Front Panel    Indicators Buttons    Please refer to the description of the TSU multiplexer front panel in   dicators and buttons in the TSU Multiplexer User Manual        61200230L1 1 Dual OCU DP Option Module and Plug on Board User Manual 3 1    Chapter 3  Operation       Menu Structure    The OCU DP menus appear as a subset of and operate the same as  menus for the TSU multiplexer  The menus are accessed by select   ing X X OCU DP under the PORT menu items     Figure 3 1 show
7. 1  OCU DP Alarm  Mess  ges       etre ce deter epis eet i eee e rae ent A 1  Index 1       ii Dual OCU DP Option Module and Plug on Board User Manual 61200230L1 1    List of Figures and Tables       Figure 1 1  Dual OCU DP Option Module                    sss eee 1 4  Figure 2 1  Installing Option Module                     sse eee nen 2 2  Figure 2 2  Installing Plug on Board                   sess eee eee eene 2 3  Figure 3 1  TSU 100 Main Menu Tree                 sse eee nee 3 2  Figure 3 2  Diagram of Loopbacks                 sse eene eene 3 11  Table2 1  Pinout for Eight Position Modular Jack Interface                         sssss 2 4  61200230L1 1 Dual OCU DP Option Module and Plug on Board User Manual iii    List of Figures and Tables          iv Dual OCU DP Option Module and Plug on Board User Manual 61200230L1 1    Chapter Introduction    DUAL OCU DP OVERVIEW    The Dual Office Channel Unit Dataport  Dual OCU DP  is one of the  option modules available for use with the ADTRAN TSU 100 600  product line  The Dual OCU DP is an all rate Office Channel Unit  Dataport  It provides signal conversion from any of the rates on the  customer loop side to a single DSO time slot  The Dual OCU DP  should be selected for use with the connection of DDS or Switched  56 DSU CSUs or other equipment which utilizes a DDS interface   The Dual OCU DP provides an interface between the T1 Multiplexer  and a DSU CSU over a 4 wire loop  up to 18 000 feet in length of  26 AWG cable  This int
8. ADRAN    DUAL OCU DP  Option Module    1200230L1    DUAL OCU DP  Plug on Board    1200231L1    USER MANUAL    61200230L1 1A  July 1998    ADRAN    901 Explorer Boulevard  P O  Box 140000  Huntsville  AL 35814 4000  Phone   256  963 8000       1998 ADTRAN  Inc   All rights reserved   Printed in USA     FEDERAL COMMUNICATIONS COMMISSION  RADIO FREQUENCY INTERFERENCE STATEMENT     This equipment has been tested and found to comply with the limits  for a Class A digital device  pursuant to Part 15 of the FCC Rules   These limits are designed to provide reasonable protection against  harmful interference when the equipment is operated in a commer   cial environment  This equipment generates  uses  and can radiate  radio frequency energy and  if not installed and used in accordance  with the instruction manual  may cause harmful interference to ra   dio frequencies  Operation of this equipment in a residential area is  likely to cause harmful interference in which case the user will be  required to correct the interference at his own expense     iG Shielded cables must be used with this unit to ensure compliance  N y P  W MMNYNS i Class A FCC limits    M Changes or modifications to this unit not expressly approved by  Ww ARNING the party responsible for compliance could void the user   s author   ity to operate the equipment     CANADIAN EMISSIONS REQUIREMENTS    This digital apparatus does not exceed the Class A limits for radio  noise emissions from digital apparatus as set out i
9. OCU DP Option Module and Plug on Board User Manual 3 3    Chapter 3  Operation       X PORT Status  Submenu of 1 Status    This menu item is used to display active status information about  the OCU DP  There are three fields that report information  The dis   play of an asterisk     indicates an item is active          OPEN IDLE ADIS                   Field Explanation   Open An asterisk will be present if the DDS loop is open or  wired incorrectly    IDLE An asterisk will be present if the OCU is detecting Con   trol Mode Idle  CMI  from the DDS loop    ADIS An asterisk will be present if the Quality Monitor Auto     disconnect feature is enabled and the OCU has received  enough improper violations to disconnect the DDS  loop                    3 4 Dual OCU DP Option Module and Plug on Board User Manual 61200230L1 1    Chapter 3  Operation       X PORT CONFIG  Submenu of 2 CONFIG    The X PORT CONFIG menu item is used for configuration of the  OCU DP Passthru Option Module     Operation    With the cursor on main menu item 2 CONFIG                                            Step Action Result  1  Press ENTER or the  The first two Configuration  number 2 key  submenu items with the  cursor on 1 NETWORK  NI   display   2  Use the down scroll  Only the bottom line of the  key to place the cur   LCD changes display   sor on X PORT CON   FIG   3   Press ENTER   4   Use the scroll keys to  identify 1 1 OCU DP   7 PORT CONFIG  PORT 4 1 OCU DP  5  Press ENTER  The first of eight sub
10. Static RAM ERROR    OCU DP Alarm Messages    The following message indicates an alarm condition on the OCU  DP Module     OPEN LOOP   Not able to detect sealing current  flowing  DSU CSU not connected or  incorrect wiring        61200230L1 1 Dual OCU DP Option Module and Plug on Board User Manual A 1    Appendix A  Failure Messages          A 2 Dual OCU DP Option Module and Plug on Board User Manual 61200230L1 1    Numerics    3 FACT RESTORE Submenu of  3 UTIL 3 7   3 PORT Test Submenu of  4 TEST 3 10   X PORT UTILITY Submenu of  3 UTIL 3 8    A  ADTRAN Shipments Include 2 1  C    Capacity 1 3  Connector 1 3  Customer Provides 2 1    D    Data Rate 1 3   Diagram of Loopbacks 3 11  Dual OCU DP Option 1 3  Dual OCU DP Overview 1 1  Dual OCU DP rear panel 1 4  Dual OCU DP  description 1 1  Dynamic Range 1 3    Index    EPROM ERROR  failure message  A 1    Failure Messages At Power Up A 1  Features 1 2  Front Panel 3 1    Indicators   Buttons  front panel 3 1  Installing the Option Module 2 2    L    Loop Interface 1 3  LOOPBACK function on OCU DP  module 3 11    Loopbacks  diagram 3 11  M    Menu Structure 3 2  Module Specifications 1 3       61200230L1 1    TSU 600 User Manual Index 1    Index       o X  OCU DP Alarm Messages A 1 X PORT CONFIG Submenu of  OCU DP Menus Are All Submenus 2 CONFIG 3 5     X PORT Status Submenu of  OPEN LOOP  alarm message A 1 1 Status 3 4  Operation Overview 3 1  P    Physical Description 1 4   Pinout for Eight Position Modular  Jack Interface 2 4 
11. erface permits the combination of DDS lines  into a single T1 stream     Functional Description    The Dual OCU DP is designed to fit in the option slot of the TSU 100  and is subject to its operation and control  The Dual OCU DP is con   figured from the front panel of the TSU 100 or by an external person   al computer  PC  program  The internal menus for its configuration  are a part of the Dual OCU DP module and are automatically in   stalled when the Dual OCU DP is plugged into the unit        61200230L1 1 Dual OCU DP Option Module and Plug on Board User Manual 1 1    Chapter 1  Introduction       Features    Operates using one DSO for each port  2 4  4 8  9 6  19 2  56  64 kbps dedicated rates  Supports Switched 56 dial up digital service    Compatible with DDS secondary channel services at rates rang   ing from 75 to 2400 bps  depending on the primary channel rate    45 dB range at all rates  Transmit attenuation available for short loops    OCU loopback toward TSU Network Interface  NI   front panel   remote  inband     Sealing current reversal to initiate loopback at the CSU  front  panel  remote  inband     Zero code suppression  Quality monitor auto line disconnect    Selectable hardware software algorithms for Switched 56 oper   ation    Interface Connector  8 pin modular    The 19 6 kbps feature is patented by INC  patent  4 862 480  The 45 dB       NOTE se feature is patented by ADTRAN  patent  4 759 035  The quality  monitor auto line disconnect feature is paten
12. fy 1 1 OCU X PORT UTILITY  DP  PORT 4 1 OCU DP  4  To select  press The option card name and the  ENTER  software version installed dis   play     OCU DP REVA       5  Press CANCEL to  exit the program or  to select another  port                       3 8 Dual OCU DP Option Module and Plug on Board User Manual 61200230L1 1    Chapter 3  Operation       x RUN SELF TEST Submenu of A TEST    This menu item is used to execute both the TSU 100 s internal test  and the OCU DP s internal test  This is the same test as is executed  upon power up  The results of the self test are displayed on the  LCD  Foradditionalinformation on self test  consult the Operation  chapter in the TSU 100 User s Manual     Follow the standard operating procedure to access the 4 TEST  menu items        Step    Action    Result       1    Place the cursor on  x RUN SELFTEST              Press ENTER        The LCD changes and shows  the test result           61200230L1 1 Dual OCU DP Option Module and Plug on Board User Manual 3 9       Chapter 3  Operation       3 PORT Test Submenu of 4 TEST    This menu item is used to activate tests of the selected data ports   Selecting the OCU DP displays two loopback tests available for this  option module     Operation    Follow standard operating procedure to access the 4 TEST menu             items   Step Action Result  1  Place the cursor on  3 PORT TEST   2 Press ENTER  The first available port dis     plays        3  Use the up and down  scroll keys to select 1 1
13. ilding  6  Suite 690  Huntsville  AL 35807    RMA      
14. menu  items appear   6  Continue with stan   dard operating pro   cedures   61200230L1 1 Dual OCU DP Option Module and Plug on Board User Manual 3 5    Chapter 3  Operation       Configuration Menu                                     Menultem Description   RATE Sets the data rate of the OCU DP   Choices    2 4  4 8  9 6  19 2  56 0 DDS  56 0 SW  64   SEC CHAN  Enables or disables the use of a secondary channel with all  data rates excluding 64 kbps   Choices    OFF or ON   QUAL MON  Quality monitor function  Auto Disable Function  Allows  the OCU DP to monitor the data it receives from the DDS  loop  If it detects violations in 7 out of 20 consecutive sec   onds  it ignores the data it receives and sends abnormal sta   tion code toward the NI  Normal operation will  automatically be restored upon receipt of 30 consecutive  error free seconds    Choices   OFF or ON   A BSIGNL  Selects either a software or hardware algorithm to be used  for SW56 operation   Choices    SW or HW   OCU DP Decodes signalling from the network and passes this to the  loop as either CMI code or data mode  The default method  of decoding signalling from the network is a software tech   nique  If the C bit  bit 8  is 0 in any of the last seven data  bytes  signalling is decoded as a 0  on hook   If bit 8 is a 1 in  all of the last seven data bytes  signalling is decoded as a 1   off hook     If the hardware  HW  option is enabled  signalling is  decoded from the A and B bits in frames 6 and 12 of the T1
15. n the interference   causing equipment standard entitled    Digital Apparatus     ICES   003 of the Department of Communications    Cet appareil nuerique respecte les limites de bruits radioelectriques  applicables aux appareils numeriques de Class A prescrites dans la  norme sur le materiel brouilleur     Appareils Numeriques     NMB   003 edictee par le ministre des Communications     Table of Contents    Chapter 1 Introduction seroma a eetn tente tte tn sts E enses ensis ensis en 1 1  Dual  OCU DP OVERVIEW xx  etit eire te PC ERE ER D Ie tren eee 1 1  Functiorial Description  atento tee ete aee ha 1 1  Features  ca eenoicime iude ein re reed leads ceca diee s D PEE ER ARRIERE acts 1 2  D  al OCU DP Options zn ite e rt rtr tee emitte n tese 1 3  Module Specifications    2 menta neret od eere tre tds 1 3   Physical D  scriptiOn    nene retient e thee e ire ertet iie a 1 4  Chapter 2 Installation soseri eee esee sette tette tnt tn testatus AEE 2 1  Unpacl Geils pectic ee edere ete RT re E He R eet enses 2 1  ADTRAN Shipments Include                    1 sese eee eene enne 2 1  Customer Provides    eise sime tee ierit o WEA ia ae 2 1  Installing the Option Module                     sss eee nee 2 2  Placement of the Option Module                eee eee nnn 2 2   Power ConnectionD         dee t e cr eese tee ee needs 2 2  Installing Plug on Board uo    ccc eese eee eene 2 3   WALID ce T 2 4  Power Up Testing and Initialization                    esses eee 2 5  Warranty And Cust
16. of the Option Module    For the proper placement of the Option Module using a TSU 100   complete the following steps   See Figure 2 1               Step Action  1 Remove the cover plate from the TSU 100 rear  panel   2 Slide the option module into the rear panel until it is    positioned firmly against the front of the TSU 100        3 Fasten the thumb screws at both edges of the option  module                 Power Connection    Each Dual OCU DP module derives power from the base TSU 100  unit        Figure 2 1  Installing Option Module       2 2 Dual OCU DP Option Module and Plug on Board User Manual 61200230L1 1    Chapter 2  Installation       Installing Plug on Board    For the proper placement of the Plug on Board  complete the follow   ing steps   See Figure 2 2         Step    Action       Hold the plug on board above the option module        Using a downward and right to left motion  slip the con   nector pane into the opening in the option module back  panel        Moving the plug on board downward  secure the con   nection of the header pins at the front of the board        Install two 4 40 screws through the rear mounting holes  of the plug on board into the mounting brackets on the  rear panel           Install two 4 40 screws through the front mounting holes  of the plug in card into two standoffs on the plug on  board                    Figure 2 2  Installing Plug on Board       61200230L1 1 Dual OCU DP Option Module and Plug on Board User Manual 2 3    Chapter
17. omer Service              sss eee eee nennen 2 5  Chapter 3 Operation MR             3 1  Operation Overview osinn isnin ensa bist than din tica edible dies 3 1  Front Panels deett ih etel tpe rca o aa A tob 3 1  Indicators BU  ttons aae eee vec te eee caulk iae a t i eee iee 3 1   Menu  Str  ct  te    x p ROREM IM oH DIRE 3 2  OCU DP Menus Are All Submenus                 essere nennen etre 3 3   Bie eios e Seance A e aa nite a vos lanl he tel tetia ot 3 3  X PORT Status  Submenu of 1 Status                sss nennen 3 4  X PORT CONFIG  Submenu of 2 CONFIG                 sese 3 5  Operation   5 stasis Tati ned pesa bogota nd otl eine teile ts 3 5  Configuration  Menus metit sp eee ee tte te tpe a pee a epe 3 6   3 FACT RESTORE Submenu of 3 JUTIL                     sees 3 7  Operation simon dune nien aitediuo aie eros 3 7   X PORT UTILITY Submenu of 3 UTIL                 esesesseeeeeee nennen 3 8  Op  ration  25 cse ieabitieenamahsbaadieimoie tenetis 3 8   X RUN SELF TEST Submenu of 4  TEST         ccccceceescecessesceseeseeeeesceaeseeeceeceeaeeeeaeeas 3 9  3 PORT Test Submenu of A4 TEST               sessssesseseeeeeeenetnn nennen enne tnn 3 10       61200230L1 1 Dual OCU DP Option Module and Plug on Board User Manual i    Table of Contents       Operatonzziceccosotien isk Beatie skies eundo ates pa non 3 10  LOOPBACK   isi eiit PER o e ha ue obe n e ERE 3 11  Appendix A Failure Messages          sssscsssessccsessessceceeessssesescsessssssesesssseceeeesseeseeeeeseeenes A 
18. s the TSU multiplexer Main Menu with the PORT  selections shaded The TSU multiplexer User Manual s appendix  TSU Multiplexer Menu Tree is a complete menu diagram              1  STATUS 1  NI PERF REPORTS  2  PORTS STATUS  1  NETWORK  NI  3  ACTIVE ALARMS  2  UNIT 4  VIEW HISTORY       3  MAP XCHNG  2  CONFIG    4 MAP IN USE                      5  DSO MAP A 1  ENTER PASSCODE  MAIN MENU 6  DSO MAP B 2  TIME DATE  7 PORT CONFIG 3  FACT RESTORE  4  REINT UNIT  3  UTIL 5  UNIT ID       6  SOFTWARE REV       1  NETWORK TESTS 7  PORT UTILITY       4  TEST 2  RUN SELF TEST       3  PORT TEST       Figure 3 1  TSU 100 Main Menu Tree       3 2 Dual OCU DP Option Module and Plug on Board User Manual 61200230L1 1    Chapter 3  Operation       OCU DP Menus Are All Submenus    The OCU DP menus are accessed from and operated the same as  menus for the TSU 100  As indicated by the bolded items in Figure  3 1 on page 3 2  the OCU DP items are submenu choices of the four  main menus     Each of the OCU DP submenu items is described in the following  sections  All are accessed by the same method        Operation  With the cursor on one of the four main menu choices  do the fol   lowing   Step  Action Results       1  Press ENTER or the  The first two submenu items  number key  display with the cursor on  the first item        2  Usethe down scroll  key to place the cursor  on the desired item     3  Press ENTER  The first two submenu  choices display                          61200230L1 1 Dual 
19. ted by ADTRAN  patent  15 450 441    1 2 Dual OCU DP Option Module and Plug on Board User Manual 61200230L1 1    Chapter 1  Introduction       Dual OCU DP Option    Module Specifications    The following list contains the modular specifications for each port        Loop Interface    4 wire  TX Pair and RX Pair        Data Rate    2 4  4 8  9 6  19 2  56 kbps including  secondary channel rates and 64  kbps  clear channel        Signal Format    Bipolar  return to zero  50  duty  cycle          TX Output  1 5 V peak  10  for rates 2 4  4 8   Amplitude 19 2  54 and 64 kbps    0 75 V peak  10  for 9 6 kbps  TX RX Source 1350  20   Impedance       Dynamic Range    0 to 45 dB loops loss for all rates  measured at a frequency of half the  data rate       Sealing Current    4 to 20 mA DC with polarity rever   sal capability       Capacity    Two DSOs  user configurable        Tests    Power on circuit test   CSU loopback initiation    sealing  current reversal    OCU loopback  loopback internal  toward MUX           Connector       8 pin modular             61200230L1 1    Dual OCU DP Option Module and Plug on Board User Manual    Chapter 1  Introduction       Physical Description    The Dual OCU DP is an option module which plugs into the option  slot in the rear of the TSU TDU family of multiplexers  See Figure  1 1  below            L OCU DP   PORT X 2          Figure 1 1  Dual OCU DP Option Module    The Dual OCU DP rear panel includes a plastic plug over a cutout  for additional
    