g20e & g20ea gsm alarm system user manual
Contents
1. Remove the SIM slot cover with screwdriver and insert a valid SIM card into the alarm host Please see 2 2 2 Make sure the power supply is connected turn on the host power switch Please see 2 3 3 Set the mobile phone telephone numbers for SMS alarm and auto dialing alarm For details please see 3 1 2 3 1 3 4 4 2 4 Set time of the alarm host for details please see 3 1 7 5 As per the operation instruction of page 13 encode the wireless detectors and remote controller to match with the alarm host and allocate the detectors to wireless zones separately Please make sure to record the corresponding zone number of each detector 6 Set zone type please see 3 1 6 for details 8 Change zone s name according to your needing Please see 4 6 for more details 9 Change password of the alarm host Please see 3 1 4 and 4 4 for more details 10 Set time of arm disarm according to your needing Please see 3 1 8 for more details For specific operation please read this manual carefully Professional designer and manufacturer of GSM Alarm Systems SHENZHEN SINDA TECHNOLOGY CO LTD ADDRESS NO 11 Building Tongfuyu Industrial Zone Xili Town Nanshan District Shenzhen CHINA TEL 86 755 26498270 26498273 FAX 86 755 26498273 Ext 13 Website http www sdph com
2. 34 Send SMS 1234DD401088888888 Note The serial number shows alarm sequence must be 4 5 6 4 3 Delete alarm phone numbers Input SMS 4 numbers for password DD serial number Example The host s password is 1234 If you want to delete the first alarm phone number Send SMS 1234DD1 Note The serial number shows alarm sequence must be 1 2 3 4 5 6 4 4 Change password of alarm host Input SMS 4 numbers for password DD 7 4 new numbers for password Example The initial password is 1234 if you want to set 5678 as the new password Send SMS 1234DD75678 4 5 Arm disarm SMS for remote arm 4 numbers for password A1 SMS for remote disarm 4 numbers for password A2 Professional designer and manufacturer of GSM Alarm Systems SHENZHEN SINDA TECHNOLOGY CO LTD ADDRESS NO 11 Building Tongfuyu Industrial Zone Xili Town Nanshan District Shenzhen CHINA TEL 86 755 26498270 26498273 FAX 86 755 26498273 Ext 13 Website http www sdph com G20E G20EA GSM ALARM SYSTEM Example The host s password 1s 1234 If you want to set the host in arm mode Send SMS 123441 4 6 Change zone s name Input SMS 4 numbers for password DM zone s code 2 numbers changed name Reply SMS Changed zone s name Example The password is 1234 If you want to change zone 06 s name to be PIR alarm for bedroom Send SMS 1234DM06 PIR alarm for bedroom Note Changed name should be less than 24 characters Zon
3. G20E amp G20EA GSM ALARM SYSTEM USER MANUAL Ver 0901 2007 09 01 G20E G20EA GSM ALARM SYSTEM Dear users Thank you for purchasing our products Please read through this manual before using this product so as to operate the product properly The GSM alarm system adopts the newest GSM network and Digital Signal Processing technology and is widely used in security field With SMS data transmission and voice platform of GSM network it really realizes wireless alarm control and remote managements and solves the limitation of wired data transmission in telephone and wired network Perfect structure convenient installation easy operation with wireless control keyboard are designed for the idea of people oriented which will make you feel easy and comfortable while use this system People is center technology is first is our company s action rule Customer Satisfaction is our consistent pursuit Perfect system excellent services sincere attitudes will bring you a new enjoyment Professional designer and manufacturer of GSM Alarm Systems SHENZHEN SINDA TECHNOLOGY CO LTD ADDRESS NO 11 Building Tongfuyu Industrial Zone Xili Town Nanshan District Shenzhen CHINA TEL 86 755 26498270 26498273 FAX 86 755 26498273 Ext 13 Website http www sdph com G20E G20EA GSM ALARM SYSTEM Contents I Instruction IT Installation 2 1 Alarm Host s section figure 2 2 Insert a valid SIM into the alarm host 2 3 Run I
4. II Operation steps 3 Set by keyboard 3 1 1 Password verification 3 1 2 Set delete three mobile phone numbers for SMS alarm 3 1 3 Set delete three phone numbers for auto dialing alarm 3 1 4 Change password of the alarm host 3 1 5 Set new ID of the alarm host 3 1 6 Set type of 8 wireless guarding zone 3 1 7 Set time of the alarm host 3 1 8 Set cancel the time of arm disarm partial arm 3 1 9 Prohibit allow sending SMS while arm disarm the system by controller or keyboard 3 1 10 Alarm 3 1 11 Exit setting status IV SMS control command 4 1 Set three mobile phone numbers for SMS alarm 4 2 Set three phone numbers for auto dialing alarm 4 3 Delete alarm phone numbers 4 4 Change password of the alarm host 4 5 Arm disarm 4 6 Change guard zone s name 4 7 Inquire host s arm disarm status 4 8 Inquire host s external power status V Usage 5 1 Arm partial arm disarm by remote controller 5 2 Emergency alarm 5 3 External power failure alarm 5 4 Alarm and handle VI Operation Cautions VII Encode the wireless detectors and remote controller Appendix Operation guideline Professional designer and manufacturer of GSM Alarm Systems SHENZHEN SINDA TECHNOLOGY CO LTD ADDRESS NO 11 Building Tongfuyu Industrial Zone Xili Town Nanshan District Shenzhen CHINA TEL 86 755 26498270 26498273 FAX 86 755 26498273 Ext 13 Website http www sdph com G20E G20EA GSM ALARM SYSTEM 1 Imstruction The alarm system adopts SMS data transmission an
5. d voice platform of GSM network to send control command and receive alarm remotely The system can be set delayed arm When a signal 1s detected by detectors the detectors will send alarm signal to host immediately then the host sends alarm SMS to its preset mobile phone numbers and meanwhile dials its preset telephone mobile phone numbers automatically and drive wiretap In addition the color LCD can show the time date and the status of arm disarm GSM signal power alarm etc With the LCD it is very easy for you to operate Following are the specific functions 1 With Wavecome double frequency GSM module 2 With color LCD show screen and keyboard on the host 3 10 wireless guarding zones 1 wireless SOS zone 1 fire alarm zone and other 8 wireless guarding zones can be defined by user and 1 external power failure alarm zone Send SMS to 3 preset mobile phone numbers automatically while alarming Call 3 preset phone numbers automatically and monitor at site while alarming 4 5 6 Set the time of arm partial arm disarm 7 Arm disarm by the keyboard on the host remote controller or SMS 8 Program the alarm host by keyboard or SMS 9 Modify the name of 8 wireless guarding zones and inquire the status of alarm host by SMS demand 10 Define the 8 wireless guarding zones as arm partial arm by keyboard on the alarm host 11 With standby rechargeable battery 12 The alarm host automatically stores system status while its p
6. designer and manufacturer of GSM Alarm Systems SHENZHEN SINDA TECHNOLOGY CO LTD ADDRESS NO 11 Building Tongfuyu Industrial Zone Xili Town Nanshan District Shenzhen CHINA TEL 86 755 26498270 26498273 FAX 86 755 26498273 Ext 13 Website http www sdph com G20E G20EA GSM ALARM SYSTEM 2 2 Insert a valid SIM into the alarm host Before installing the host remove the SIM slot cover with screwdriver and insert SIM card 2 3 Run Make sure that the power supply is connected correctly and turn on the host power switch The alarm host will search the GSM network automatically within 25 seconds after it is started Then the LCD display turns on and shows the time and the status of arm disarm GSM signal etc The COM is twinkling When the external power is normal the LCD display keeps on If there is no external power it is off automatically after operation III Operation steps Note When setting by the keyboard every time you press the button you will hear di sound for confirmation If there s no voice you can press it again To cancel the input numbers please press CLS button before inputting OK If the LCD display shows FAIL please check and reset it 3 1 Set by keyboard 3 1 1 Password verification Press SET input password OK then you will hear di d1 sound for confirmation While SET and SMS appear on LCD display it means that the password is correct Note The initia
7. e s code 01 to 08 each code with two numbers 4 7 Inquire host s arm disarm status Input SMS 4 numbers for password W1 Reply SMS The host s arm disarm status 4 8 Inquire host s external power status Input SMS 4 numbers for password W2 Reply SMS The host s external power status V Usage 5 1 Arm disarm by remote controller a Arm Press mb on remote controller the host will make di sound the LCD display is on mb is twinkling 30 seconds later the host enters into arm mode and the imi is on If you want to arm the system quickly please press Se gt b Partial arm press el the host will make di sound the LCD display is on f is twinkling 30 seconds later the host enters into partial arm mode and t is on Press the the host will enter into partial arm mode immediately c Disarm Press m to close the system the host enters into disarm status after the host makes di di sound and the m ison 5 2 Emergency alarm When an emergency alarm occurs press and the host will enter into emergency alarm status immediately and the siren will alarm for 90 seconds to inform the neighbors At the same time it will automatically dial the preset alarm phone numbers cycled for three times and send SMS of Emergency alarm 5 3 External power failure alarm When the system checks out that there is something wrong with the external power or the external power is off for more tha
8. ems SHENZHEN SINDA TECHNOLOGY CO LTD ADDRESS NO 11 Building Tongfuyu Industrial Zone Xili Town Nanshan District Shenzhen CHINA TEL 86 755 26498270 26498273 FAX 86 755 26498273 Ext 13 Website http www sdph com G20E G20EA GSM ALARM SYSTEM Input serial number OK then you can cancel it 3 1 4 Change password of the alarm host After passing the verification of password press SET when SET PAS appears on the LCD display Input 7 new password OK Example Set 4321 as the new password Input 7 4321 OK then you will hear di di sound for confirmation Note The initial password 1s 1234 must be four numbers 3 1 5 Set new ID of the alarm host After passing the verification of password press SET when SET ID appears on the LCD display Input 0 six new ID numbers OK Note the initial ID is 000000 Example Set 123456 as the new ID Input 0 123456 OK then you will hear di di sound for confirmation 3 1 6 Set type of 8 wireless guarding zones After passing the verification of password press SET when SET TYPE appears on the LCD display Input zone numbers When there is illegal intrusion the zones will alarm in partial arm mode OK Example Set zone 4 6 8 as alarm zones in partial arm mode input 468 OK then you will hear di di sound for confirmation When alarming zone 4 6 8 will alarm but other five zones will not alarm i
9. ilding Tongfuyu Industrial Zone Xili Town Nanshan District Shenzhen CHINA TEL 86 755 26498270 26498273 FAX 86 755 26498273 Ext 13 Website http www sdph com G20E G20EA GSM ALARM SYSTEM 3 1 9 Prohibit allow sending SMS when arn disarm the system by controller or keyboard After passing the verification of password press SET when SET appears on LCD display input 9 OK then you will hear di di sound for confirmation 3 1 10 Alarm When the host alarms Le SMS TEL and guarding zones will appear on the LCD display and it will drive siren to sound for 90 seconds P external power failure E SOS alarm F fire alarm 1 8 wireless guarding zone 3 1 11 Exit setting status In the setting status the host will exit automatically if there is no response within 15 seconds After setting successfully press ESC to exit IV SMS control command 4 1 Set three mobile phone numbers for SMS alarm Input SMS 4 numbers for password DD serial number mobile phone number Example Set 1388888888 as the first mobile phone number for SMS alarm The host s password is 1234 Send SMS 1234DD11388888888 Note The serial number shows alarm sequence must be 1 2 3 4 2 Set three phone numbers for auto dialing alarm Input SMS 4 numbers for password DD serial number phone number Example Set 01088888888 as the first phone number for auto dialing alarm The host s password is 12
10. ke out the SIM card Connect the power supply firmly and provide good heat dissipation Don t install the system close to the objects which generate strong interference such as TV set and computer Check all the detectors and their battery in time and change them when voltage is low Inspect the GSM alarm system termly we 1 oe 215 o This product is designed for the indoor use rather than outdoor use VII Encode the wireless detectors and Remote controller Professional designer and manufacturer of GSM Alarm Systems SHENZHEN SINDA TECHNOLOGY CO LTD ADDRESS NO 11 Building Tongfuyu Industrial Zone Xili Town Nanshan District Shenzhen CHINA TEL 86 755 26498270 26498273 FAX 86 755 26498273 Ext 13 Website http www sdph com G20E G20EA GSM ALARM SYSTEM There is a label with wireless address code on the back of alarm host It is corresponded to AQ A7 Alarm Host from right to left Remote Controller PIR Sensor Zone02 tj Door Zone04 1 contact AO A7 The same as the wireless Zone 05 1 1 Beam address code of alarm host 0 0 1 1 Zone 06 Gas detector Emergency button Remark 1 Request High level N connect with H detector etc O Request Low level N connect with L oe Operation 2 No connect NC No request Guideline By following steps you can operate it easily though it 1s the first time to use this product
11. l password is 1234 must be four numbers 3 1 2 Set delete three mobile phone numbers for SMS alarm a Set the mobile phone number After passing the verification of password press SET button when SET SMS appears on the LCD display input serial number mobile phone number OK Example Set 1368888888 as the first mobile phone number for SMS alarm Input 1 1368888888 OK then you will hear di di sound for confirmation According to the method you can finish the setting of the other two mobile phone numbers Note Serial number can only be 1 2 3 and the number 1 is the first mobile phone number for SMS alarm The phone No must be less than in 20 numbers b Delete the mobile phone number Input serial number OK then you can cancel the mobile phone numbers 3 1 3 Set delete three phone numbers for auto dialing alarm a After passing the verification of password press SET button when SET TEL appears on the LCD display Input serial number phone number OK Example Set 1368888888 as the first phone number for auto dialing alarm Input 4 1368888888 OK then you will hear d1 di sound for confirmation Note Serial number can only be 4 5 6 and the number 4 is the first phone number for auto dialing alarm The phone number can be mobile phone or telephone but mustn t be more than 20 numbers b Delete the phone number Professional designer and manufacturer of GSM Alarm Syst
12. n 2 seconds it will enter into alarm status immediately At the same time the system will automatically dial the preset phone numbers cycled for three times and send the SMS of External power failed When the power supply is on the system will stop alarming immediately and send the SMS of External power is OK 5 4 Alarm and Handle Professional designer and manufacturer of GSM Alarm Systems SHENZHEN SINDA TECHNOLOGY CO LTD ADDRESS NO 11 Building Tongfuyu Industrial Zone Xili Town Nanshan District Shenzhen CHINA TEL 86 755 26498270 26498273 FAX 86 755 26498273 Ext 13 Website http www sdph com G20E G20EA GSM ALARM SYSTEM When an alarm occurs the siren will alarm for 90 seconds to inform the neighbors At the same time the system will automatically send SMS to report the guarding zones and dial the preset phone numbers When any phone is answered you can monitor the alarm site If the phone line is busy or can t put through the system will auto dial the next phone number circularly till one of them is answered If nobody answers the phone the Wireless address code of product system will stop AO to A7 DO D1 D2 D3 dialing after Ae Note You can see the code A0 A7 from 13 12 11 10 auto dialing PCB in the products circularly for three times VI Operation Cautions 1 Make sure the eguipments have no water Install the system in a hidden place Turn off the power supply before insert ta
13. n partial arm mode 3 1 7 Set time of the alarm host After passing the verification of password press SET when SET appears on the LCD display Input 8 year month day hour minute second each with two numbers OK then you will hear di di sound for confirmation Example Suppose the present time is 12 13 05 and the date is 08 01 2007 input 8 070108121305 OK 3 1 8 Set cancel the time of arm disarm partial arm a Timing arm In arming status press SET when SET appears on the LCD display then Input time hour minute OK Example Set 16 08 as the arm time input 1608 OK then you will hear di di sound for confirmation To cancel it press 9999 OK in arm mode b Timing partial arm In partial arm status press SET when SET appears on the LCD display then input time hour minute OK Example Set 16 25 as the partial arm time input 1625 OK then you will hear di di sound for confirmation To cancel it press 9999 OK in partial arm mode c Timing disarm In disarming status press SET when SET appears on the LCD display then input time hour minute OK Example Set 16 35 as the disarm time input 1635 OK then you will hear di di sound for conformation To cancel it press 9999 OK in disarm mode Professional designer and manufacturer of GSM Alarm Systems SHENZHEN SINDA TECHNOLOGY CO LTD ADDRESS NO 11 Bu
14. ower is off 13 Connect with the alarm center through GSM network Specification a GSM GSM frequency 900 1800M Hz or 850 1900MHz Consumption 1W while sending message b Working frequency of detectors 315M amp 433M optional c External power failure alarm Start time less than 2s d Alarm response time Less than 8s GSM in normality e The volume of siren More than 110db Professional designer and manufacturer of GSM Alarm Systems SHENZHEN SINDA TECHNOLOGY CO LTD ADDRESS NO 11 Building Tongfuyu Industrial Zone Xili Town Nanshan District Shenzhen CHINA TEL 86 755 26498270 26498273 FAX 86 755 26498273 Ext 13 Website http www sdph com G20E G20EA GSM ALARM SYSTEM f Power Power reguirements AC 110 220V 50Hz or 60Hz Working power consumption less than 3W Standby battery DC 8 4V Standby battery working hours more than 15 Hours g Working conditions Operating temperature 20C 60 C Humidity 20 to 95 h Weight of alarm host Net weight 0 5Kg Gross weight 0 75Kg i Dimension of alarm host Dimension 160mm Long x113mm Wide x38mm High II Installation 2 1 Alarm Host s section figure Sa fay n KOM T A ad LE NN Pen E 1 rg Yay Sinn Zip Sa Sp Popi con y o Po My y 7 fe Ure Ory f Da 3r Partial arm Disarm Year Month Day Hour Minute antenna MIC LCD display EXT MIC EXT MIC Keyboard Siren sockel lPower socket Power switch 4 Lover Professional
Download Pdf Manuals
Related Search
Related Contents
Chapter 8 ick Start Manual – Viewer Mode ARES um RSO Admin User Guide V2 DRAFT V0.52 Jul14 Craftsman 24 in. Digital LaserTrac Level Owner's Manual Instrucciones de manejo Balanzas NewClassic OPERATING INSTRUCTIONS Seip TM80 Electric Garage Door Philips Pure Essentials Collection Hand blender HR1370/91 ユーザーズマニュアル El servicio regular le ayudará a mantener su motocicleta H Copyright © All rights reserved.