Instruction Manual DEGA PBC-EL II
Contents
1. INSTRUCTION A DEGA MANUAL 22 Portable Carbon Monoxide Detector DEGA PBC EL II ISO 9001 2008 p Quality Management Systems hy Syst me de Qualit is www sgs com an 7 Content a AX a LE Page 2 For your protection Fa Page 3 Technical data and information j E Pot Page 3 Description of the product a LCD display Page 3 Directions for use Connecting the battery is Switching the device on and off ki Turning the display backlight on and off Setting the detection limit a Alarm activation Page 3 Caution Page 3 Basic information concerning carbon monoxide Page 4 Testing the detector Page 4 Maintenance Page 4 General warranty terms and conditions Reproduction of this manual or any part thereof in any form without the prior written permission of DEGA CZ s r o is prohibited DEGA CZ s r o reserves the right to alter the specifications of the hardware and software described in this manual at any time and without prior notice DEGA CZ s r o bears no liable for any damage resulting from the use of this device v FOR YOUR PROTECTION In the event of an equipment failure immediately disconnect the item from the power supply i i e remove the battery If you notice any unusual odour or smoke emanating from the product remove the battery and allow the product checked at an authorised service centre or by the manufacturer i Do not use the device near flammable gases or in areas w
2. erials Avoid the contact of the detector with any of these substances v MAINTENANCE In the case of serious contamination disconnect the detector from the battery and clean the surface of the detector with a damp cloth To maintain the proper functioning of the detector it is also necessary to calibrate the instrument to carry out calibration at least once a year i e setting the detection limits checking the responsiveness of the sensor checking the functionality of the detector The exact time interval depends on the purity of the environment the level of accura cy required and the occurrence of selective gases in the environment Note In the event of frequent use we recommend carrying out calibration at least once every six months Calibrate the device at an authorised service centre holding a valid certificate from the manufacturer or at the manufacturer s premises v GENERAL WARRANTY TERMS AND CONDITIONS When following the instructions for installation operation and maintenance the manufacturer guarantee 24 months from the date of receipt for the product Should the product purchased be put into operation by an entity other than the seller the warranty period commences from the date that the product is put into operation provided that the buyer ordered its commissioning within three weeks of its receipt The customer expressly acknowledges that during the warranty period that extends beyond the length of the warranty period that i
3. here there is the potential presence of such gases Do not use electronic equipment in the presence of a flammable gas this could cause a fire or an explosion The product is not designed for use in industrial or commercial spaces nor in Ex hazardous areas For applications of this nature we recommend the use of DEGA M Sx yl Il or P Sx Multi II Ci Do not disassemble the product and ensure against its contact with water Contact with internal components of the product may cause an electric shock In the case of any failure refer the servicing of the product exclusively to a certified service centre Contact with water can create a short circuit in the product and consequent damage to property or personal injury v TECHNICAL DATA AND INFORMATION Supply voltage 3x AA batteries 1 5 V preferably alkaline Battery life about 100 hours with the backlight switched off Type of sensor electrochemical Expected operational life of the sensor in a clean environment 2 years max 3 years Operating temperature range max 10 C to 50 C Relative humidity of the ambient air 0 to 90 The range of measurable values 0 1000ppm Resolution 1ppm Measurement error 5 Type of signalling Acoustooptical Dimensions 172 x 51 x 26mm v DESCRIPTION OF THE PRODUCT 1 Display 2 Button for adjustment of the value jns 3 Button for moving the cursor E 4 Holding the MODE ON button for t 2 seconds switches on the device 5 Le
4. ing to be in use for an extended period turn it off and remove its batteries to avoid the leakage of electrolyte and damage to the detector Removing the battery from the device while it is switched on leads to the loss of the limit setting for signal levels 1 and 2 When you switch the device on again the default values for the alarm limits will be re established In order to retain the settings for the user s alarm limit values the device must be properly switched off prior to removing the batteries 7 A large difference between the concentration of carbon monoxide measured in the fresh air and value of 0 ppm points to the necessity for recalibration v BASIC INFORMATION ON CARBON MONOXIDE Concentration Explanation effects 0 1ppm normal concentration of carbon monoxide in the air v TESTING THE DETECTOR 1 For testing purposes use only the calibration gases Never test the detector using cigarette smoke 2 If the detector shows a different value of concentration than that of the calibration compound re calibrate the detector CAUTION IF THE ALARM SOUNDS AND YOU ARE NOT PERFORMING THE TEST THIS REPRESENTS A REAL ALARM THIS ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION Compounds that may affect or damage the sensor and cause erroneous measurements include methane propane isobutane isopropanol ethyl acetate alcohols lacquers paints thinners solvents glues hair spray aftershave perfume and certain cleaning mat
5. s specified in the Commercial Code the statutory warranty s he can neither require replacement of the product nor may s he withdraw from the contract 1 Claims concerning the product for a warranty repair only complete devices are accepted may be filed during the warranty period only with the seller from which it was purchased subsequently the seller is required to forward the product to an authorised service centre or to the manufacturer 2 This warranty is not applicable to damage caused by fire water static electricity power surges in the electric supply or in the public network accident improper use of the product wear and tear contamination of the product and its subsequent cleaning damage caused by improper installation any adjustment modification or improper manner of use inconsistent with the instruction manual the technical standards or the applicable safety regulations in the Czech Republic damage to the product during transportation caused by improper handling or handling of the product in a manner contrary to the advice provided in the instruction manual Detector calibration settings DEGA products that have been used in association with other than original DEGA products including consumables and accessories bearing additional parts or consumables e g a foil label seal etc that are detrimental to normal wear and tear during operation together with wear and tear of the product and its parts cau
6. sed by their normal use 5 Claims regarding a product defect that can be dealt with reasonably quickly and without additional consequences will be resolved by remedying the defect repair or by replacement of the product part because in such a case it is a contradiction of the standard norms that the entire product shall be replaced 616 paragraph 4 of the Commercial Code 6 The buyer who exercises the right of warranty repair is not entitled to the return of the parts that have been replaced 8 For the complete version of the general business conditions and of the claims procedure go to www dega cz Manufacturer DEGA CZ s r o K i kovu 640 9 190 00 Prague 9 Czech Republic Tax ID CZ 279 029 43 Company ID 279 02 943 Telephone cz 420 774 447 660 5 Fax 420 227 203 512 E mail info dega cz Web www dega cz 2012 DEGA CZ S R O USER MANUAL VER 04DEGAPBCII201210 a p LESA RoHs CE 2
7. vel 2 alarm red LED 6 Level 1 alarm yellow LED 7 Holding the MODE OFF button for 2 seconds switches off the device 8 Piezo buzzer 9 Sensor 10 Cover of the battery compartment LCD DISPLAY bid 1 The numerical value of the gas concentration 2 The measurement mode SCAN ALAI ALA2 3 Signal level 1 4 Signal level 2 5 Units 6 Zero point calibration 7 Battery charge status Mm ER ppm v DIRECTIONS FOR USE CONNECTING THE BATTERY Pull on the back cover to remove it and insert 3 x 1 5 V AAA alkaline batteries Pay attention that their polarity is correct SWITCHING THE DEVICE ON AND OFF With charged batteries switch the device on by pressing and holding the MODE ON button for 2 seconds After it is switched on the device it will be in the measurement mode and the display will show SCAN Switch the device off by pressing and holding the MODE OFF button for 2 seconds TURNING THE DISPLAY BACKLIGHT ON AND OFF In the measurement mode the display will show SCAN press the MODE OFF button and the backlight will turn on or off SETTING THE DETECTION LIMIT THE VALUES OF THE DETECTION LEVELS The default setting for alarm limit at signal level 1 is 35 ppm for signal level 2 it will be 100 ppm Note In case of the requirement for setting different limits contact your dealer or authorised service centre or the manufacturer to set these other limits calibration of the device
8. will be carried out at the same time ALARM ACTIVATION The alarm will sound when the value measured exceeds the preset alarm limit When the alarm limits of level 1 are exceeded the acoustic alarm will switch on at signal level 1 and the yellow indicator will start flashing When the alarm limits of level 2 are exceeded the acoustic alarm will switch on at signal level 2 and the red light will start flashing v CAUTION 1 This detector is a sensitive measuring instrument Avoid damaging it and keep it away from water and hot objects with a temperature of above 60 C 2 In the event of long periods of measurement turn off the backlight thereby you will reduce the energy consumption of the appliance and prolong its battery life 3 If the display is showing the Emm symbol the battery is fully charged During gradual discharging the dark coloured boxes on the display decrease The L gt symbol indicates that the battery status of your device is too low for it to function normally In this case the battery should be replaced as soon as possible Turn off the unit and then remove the old batteries and insert new ones 4 If no button has been pressed while the detector has been in the setting mode for 10 minutes it turns off automatically 5 The activation of the acoustic alarm indicates that the concentration of carbon monoxide has exceeded the alarm limit Take all requisite steps to protect lives and property 6 If the unit is not go