1. MODEL MQ5600 MQ5700 READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE MIRIAL Compressor Nebulizer INSTRUCTIONS INDEX 1 Introduction _ Page 2 2 Product Identification _ Page 3 3 Important Safeguards Page 3 4 Operating Your Compressor Nebulizer Page 4 5 Cleaning Page 5 6 Replacement Parts amp Accessories _ Page 6 7 Specifications Page 7 8 Warranty inn Page 8 1 INTRODUCTION Thank you for purchasing the A RIAL Compressor Nebulizer This product is a compact medical device designed to efficiently deliver physician prescribed medication to the bronchial lung passages for the treatment of asthma allergies COPD and other respiratory ailments With proper care and use it will provide you with many years of reliable treatment The AIRIAL is intended for use with a single adult pediatric or infant patient This product creates a stream of air that travels through a clear tube to the nebulizer When air enters the nebulizer it will convert the prescribed medication into aerosol mist for easy inhalation Your A RIAL should be used on
2. 2 Do not run this product unattended 3 Never operate the unit if it has any damaged parts including power cord or if it has been dropped or submersed in water Promptly send it to a service center for examination and repair 4 If any abnormality occurs discontinue use immediately until the unit has been examined and repaired Always unplug the product immediately after use Never block the air openings of the main unit or place it where the air openings may be obstructed oa Storage Cautions 1 Do nat store the unit in direct sunlight high temperatures or high humidity 2 Keep the unit out of reach of small children 3 Always keep the unit unplugged while not in use Cleaning Cautions 1 Do not immerse the unit in water It may damage the unit 2 Disconnect the unit from the electrical outlet before cleaning 3 Clean all necessary parts after each use as instructed in this guidebook Save These Instructions 4 OPERATING YOUR COMPRESSOR NEBULIZER Important Prior to initial operation this product should be thoroughly cleaned per the Cleaning Procedures in this guidebook 1 Place your Compressor Nebulizer on a flat and stable surface Be sure that you can easily reach the controls when you are seated 2 Gently twist the top part of the nebulizer counter clockwise to disassemble the nebulizer 3 Fill the bottom section of the nebulizer with the medication prescribed by your Physician Be sure that the
3. anesthetics or oxygen Mode of operation 20 min on amp 40 min off 8 WARRANTY MEDQUIP Inc warrants this compressor to be free from defects in materials and workmanship under normal use and operation for a period of five 5 years from date of purchase This warranty is limited to repair or replacement at MEDQUIP Inc s sole option of any such component or equipment claimed to be defective when claim is shown to be legitimate by MEDQUIP s technical evaluation department This warranty does not extend to any components or equipment subjected to misuse improper operation accidental damage or unauthorized repairs and is not extended to charges of or for labor repairs All items returned must be properly packaged and shipped prepaid by the individual s or company returning the product Neither MEDQUIP Inc nor its affiliates shall be liable to purchaser or others for loss of use of equipment or for indirect or incidental or consequential damages that might arise Please Save These Instructions for Future Reference Q mEDQUIP P O Box 1559 Bluffton Sc 29910 Ta 888 404 5666
4. cone is put Place cone inside inside the bottom section i and fill medication 4 Gently twist the top part clockwise to reassemble the nebulizer Be sure the 4 an Co 10 5 two sections fit well Attach one end of air tube to the base of the nebulizer Attach the other end of air tube to the air tube connector located on the back of the compressor Attach the interface accessory of your choice to the top section of nebulizer Plug the power cord into an appropriate electrical outlet Make sure at this stage the power switch is at OFF status Press the power switch to ON status to begin your prescribed treatment Important The compressor motor has a thermal protector which will shut off the unit before the unit is overheated When the thermal protector shuts the unit off please a Switch off the unit b Unplug the unit from the electrical outlet c Wait 30 minutes for the motor to cool down before another treatment d Make sure the air openings are not obstructed When treatment is finished shut off the unit and unplug it from the electrical outlet CLEANING It is recommended that the nebulizer and the mask or any other patient accessory interface that is used be thoroughly cleaned with hot water after each use and cleaned with a mild detergent after the last treatment of the day If your physician or respiratory therapist specifies a different cleaning procedure follow their ins
5. o not wash or clean the filter 1 Change the filter every 30 days or when the filter appears dirty and gray 2 Changing procedure A Remove the filter cover B Replace the used filter with a new filter C Replace the filter cover 6 REPLACEMENT PARTS AND ACCESSORIES Contact your healthcare distributor for replacement parts or accessories 7 SPECIFICATIONS Power AC 120V 60Hz 230v 50Hz Current Max 1 5A 0 8A Medication Capacity 5ml Particle Size 0 5 to 10 um MMAD 4 um Sound Level lt 62 dBA 1 m away Maximum Medication capacity 13ml cc Average Nebulization Rate gt 0 18ml min Compressor Pressure Range 17 4 to 29 Psi 0 12 to 0 2 Mpa Operating Pressure Range 7 25 to 10 Psi 0 05 to 10 07 Mpa Liter Flow Range 5 8 lpm Operating Temperature Range 10 C to 40 C 50 F to 104 F Operating Humidity Range 10 to 95 RH Storage Temperature Range 20 C to 60 C 4 F to 140 F Storage Humidity Range 10 to 95 RH Dimension L x W x H 170 136 90mm Weight 1 18 kg Standard Accessories nebulizer air tube filters 5pcs mouthpiece Protection against electric shock E Class II Equipment 4 Type BF applied parts Mask baby pacifier Protection against harmful ingress of water IPX0 Ordinary Degree of safety in the presence of flammable anesthetics or oxygen No AP APG Not suitable for use in the presence of flammable
6. the order of physician We encourage you to read this guidebook thoroughly to learn about the features of this product Any use of this product other than its intended use should always be avoided 2 2 PRODUCT IDENTIFICATION Nebulizer gt po Mouth Piece Y E ME Air Tube S S J Filtre 5pcs Air Filter amp Cover Tube Connector Power Switch Air Vents 3 IMPORTANT SAFEGUARDS Note Read all instructions carefully before use The following basic precautions are needed when using an electrical product Caution Failure to read and observe all precautions could result in personal injury or equipment damage Product cautions 1 To avoid electrical shock Keep the unit away from water Do not immerse the power cord or the unit in liquid Do not use while bathing Do not reach for a unit that has fallen into water immediately unplug the unit 2 Never operate the unit if it has any damaged parts including power cord or if it has been dropped or submersed in water Promptly send it to a service center for examination and repair 3 The unit should not be used where flammable gas oxygen or aerosol spray products are being used 4 Disconnect the unit from the electrical outlet before cleaning filling and after each use 3 5 Do not use other attachments unless recommended by manufacturer Operating Cautions 1 Connect this product to an appropriate voltage outlet for your model
7. tructions Caution Before cleaning make sure the power cord is disconnected from the main outlet and the unit Rinsing after each treatment 1 NA Disconnect the air tube from the nebulizer Disconnect the mask or other patient accessory interface from the nebulizer Gently twist the top part of the nebulizer counter clockwise to disassemble the nebulizer Rinse the nebulizer and mask or other patient interface with water Let these components air dry away from direct sunlight Reassemble the nebulizer when completely dry and put these parts in a dry sealed container Disinfecting Please follow the following steps to disinfect your nebulizer unless otherwise specified by your physician It is suggested that the unit is disinfected after the last treatment of the day 1 Use one part white vinegar with three parts distilled water Make sure mixed solution is enough to submerge the nebulizer mouthpiece and mask 2 Complete Rinsing Steps 1 3 3 Wash nebulizer mouthpiece and mask in warm water and a mild detergent Then wash them in hot tap water 4 Submerge these parts in the vinegar and water solution for thirty minutes 5 Complete Rinsing Steps 3 5 Cleaning the Compressor 1 Wipe daily with a damp cloth 2 Do not use any powdered cleaners or soap pads which may damage the finish Filter change Caution Do not operate the compressor without a filter Only use filters supplied by your distributor D
Download Pdf Manuals
Related Search
Related Contents
OS Mini OSD user manual Gen-Os Retour d`expérience: gestion de crise d`épidémie - CLIN Paris-Nord THE GAS KETTLE BARBECUE Acer G7 G247HLbid 分譲マンションなりではの賃貸管理 Product Profile Módulos 16 ED 24/48 Vdc Opto PO1000/PO1003 Copyright © All rights reserved.
Failed to retrieve file