Home

MOBILE CALL GSM alarm system

image

Contents

1. For example turn on the function of timely arm disarm Operating method 39 gt 1 gt E Alarm Number Setting In setup state input 51 56 then input the voice alarm receiving number mobile number or telephone number and then press to confirm The main unit will make a long beep the Signal indicator will flicker once and you will hear setting completed which indicate voice alarm receiving number is set successfully Operating method XX gt YY YY gt 14 ALARM SYSTEM V1 0 XX indicates the 1 6 alarming user number 51 56 YY YY indicates voice alarm receiving phone number For example set 13811111111 as the first voice call number Operating method 51 gt 13811111111 gt LCD display i l l a Delete P l l In setup state input T51 150 and then press to confirm the main unit will make a long beep and the Signal indicator will flicker once and you will hear delete completed which indicate the alarming user number is deleted successfully Operating method XX gt XX indicates the 1 6 alarming user number 51 56 For example Delete the third alarming user number from the system Operating method 53 gt E I Hoesa l E SMS Receiving Number Setting LCD display SMS Receiving number means when system is alarming it will only send SMS to this mobile number You can set maximum 3 SMS num
2. 4 Main unit starts a 30 second two way intercom During this time the main unit cannot be controlled by the mobile until 30 seconds later H Remote Control Dial the number associated to the alarm main unit by phone mobile phone and after one ringing cycle you can hear a voice prompt Please enter password If the password is right you will here Press 1 to arm Press 2 to disarm Press 3 to Monitor Press 4 to Intercom If the password is wrong you will hear a prompt voice wrong password please re enter Press 1 arm if finished successfully you will hear a voice prompt System armed Press 2 disarm if finished successfully you will hear a voice prompt System disarme Press 3 monitoring for 30 seconds to continue monitoring press 3 again to monitor for another 30 seconds Press 4 two way intercom for 30 seconds You can t operate the main unit during this time E Emergency Help Be ALARM SYSTEM V1 0 Press Emergency O button on keypad or y button on remote controller or wireless panic button the main unit will alarm and make call to the preset user numbers E System Dialing Function In disarm status you can use the main unit to make any call just like a land line telephone Dial telephone number on keypad press 9 button the main unit will make a beep and the Signal indicator will be flashing After the call press L I button again th
3. ALARM SYSTEM V1 0 of the time you want to set to arm and finally input to confirm You will hear a long beep and a voice prompt setting completed Operating method XX gt AA gt BB gt XX indicates the address code 33 34 35 of the timely arming AA indicates the hour of the setting time BB indicates the minute of the setting time For example set the arm time as 45 10pm Operating method 33 gt 22 gt 45 gt LCD display 2 Timely Disarm In setup status use keypad to input 36 38 then input the hour AA and minute BB of the time you want to set to disarm and finally input to confirm You will hear a long beep and a voice prompt setting completed Operating method XX gt AA gt BB gt XX indicates the address code 36 37 38 of the timely disarming AA indicates the hour of the setting time BB indicates the minute of the setting time For example set the arm time as 55 7pm 13 2 ALARM SYSTEM V1 0 Operating method 33 gt 22 gt 45 gt LCD display 3 Timing Control In setup status use keypad to input 39 then input the number indicating turning on timely arm disarm 1 0 and then input to confirm You will hear a long beep and a voice prompt setting completed The factory default is off Operating method 39 gt 0 1 gt 0 turn off the function of timely arm disarm 1 turn on the function of timely arm disarm
4. ALARM SYSTEM V1 0 MOBILE CALL GSM alarm system User s Manual Profile For a better understanding of this product please read this user manual thoroughly before using it ALARM SYSTEM V1 0 Catalogue Function Introduction Alarm Host Diagram Functions Settings Initialization Enter Settings Exit Settings Factory Reset Coding of Remote Controller Delete Remote Controller Coding of Defense Zong Delete Defense Zone Change Password Change Operation Password Change Program Password Clock Setting Timing Settings Timely Arm Timely Disarm 10 11 12 12 12 SMS Number Setting Delete SMS Number Defense Zone Programming Home Arm Defense Zone Setting Voice Recording Siren Setting Operation Instructions System Status Remote Controller Operate Out Arm Home Arm Disarm Answer Alarm Call Remote Control Emergency Help System Dialing Function Alarming Record Checking Maintenance da 14 15 16 17 18 18 19 19 19 20 20 21 21 22 23 23 23 25 ALARM SYSTEM V1 0 Timing Control 13 System Checking 25 lAlarm N
5. YSTEM V1 0 H Enter Settings In the state of disarm input 4 digit password by the keypad on the main unit and press button to confirm You will hear a voice prompt please enter instruction At the same time SET indicator is on without flashing and 0000 displays on the screen indicating the system enters setting status You can perform different settings repeatedly as long as the system keeps in setting status The system will exit setting mode and return to disarm status if you don t press any keypad button for 40 seconds Note In setting status press o can delete the numbers input The system default password is 8888 Operating method XXXX gt X indicates the new 4 digit password m l l I l l l E Exit Settings LCD display Press and buttons the main unit emits a long beep and exits settings The SET indicator goes out and the system returns to disarm state Operating method gt ALARM SYSTEM V1 0 m Factory Reset In disarm status use keypad to input 95175308246 and press to confirm all the LED indicators will be on for 2 seconds and you will hear a long beep The main unit gets all its settings cleared and restores to its factory settings successfully Operating method 95175308246 E Coding of Remote Controller The remote controller has to be code to the alarm host in order to perform normally In se
6. as barriers such as reinforced concrete wall or fire door etc Alarm Panel front schematic diagram y ser som MOBILE CALL ALARM Functions Indicator Defense Zone Indicator TO Out Arm E Home Arm 2 3 o Alarm Siren 5 b SJ op 2 a 3 Emergency o r baie AAA Call out ALARM SYSTEM V1 0 Alarm Panel back schematic diagram da Ae SIM Card Socket Power Switch DC 12V Input Lead wire Slot Wire Connector PCB Panel Battery Case Wired terminal block D tjela lalana lal ala EIE maz z z z SJAJNI SININ GS N N ZG NN No 18 EE D E e a AU A EC Y ALARM SYSTEM V1 0 LCD display E FRREEREN z Ae zb mn e Fire Alarm Gas Leakage Window Alarm Door Alarm SOS Hall Alarm Balcony Alarm Boundary Alarm Function Settings E Initialization Please insert SIM card and plug in power adaptor and then power on the system all the LED lights will be on for 2 seconds and you will hear a long beep the system comes into initialization After the time clock displays on the LCD screen the SGM starts flashing and the main unit starts to detect the GSM network until a long beep Then the SGM indicator goes out indicating the system comes into disarm status Finally turn on the backup battery switch 6 ALARM S
7. bers In setup state input 57 59 then input the SMS receiving number and then press aL Ses ALARM SYSTEM V1 0 button to confirm The main unit will make a beep the Signal indicator will flicker once and you will hear setting completed which indicate setup successfully Operating method XX gt YY YY gt XX indicates address codes of message receiving numbers from the first group to the third group 57 59 YY YY indicates the SMS receiving number For example setup 13822222222 as the first SMS receiving number Operating method 57 gt 138222222 gt gt E Delete SMS Receiving Number In setup state use keypad to input 57 59 and then press button to confirm The main unit will make a beep the Signal indicator will flicker once and you will hear delete completed which indicate SMS number is deleted successfully Operating method XX gt XX indicates address codes of message receiving numbers from the first group to the third group 57 59 For example delete the first SMS user number from the system Operating method 57 gt E Defense Zone Programming If you want to change the alarm attribute of defense zone such as turn off the siren 16 ALARM SYSTEM V1 0 when system alarms you can do it by defense zone programming In setup state first input 60 then the defense zone number 01 99 then input defense zone type 1 4 the
8. defense zone 1 99 will not alarm when detector triggered except 24 hours defense zone System setup status In this status all defense zones will not alarm when detectors are triggered Remote Controller Operation Users can use remote controller to set system as Out Arm Home Arm Emergency Alarm Real time Disarm and etc Out Arm Press A button Disarm Press button Home Arm Press 4 button Emergency Alarm Press A button system will alarm at once Out Arm It means to guard all around your house while everyone is going out all the detectors of the host are always working when the detector is triggered by detecting source anti theft fire prevention gas leak etc the alarm system will sound the alarm Press Out Home button on keypad system will make a beep per second and totally 100 beeps The OUT ARM indicator will be on without flashing It means 20 ALARM SYSTEM V1 0 Out Arm is set successfully Arm Operation Press Out Home button LCD display E Home Arm It means for the safety while somebody is at home you need to enable the peripheral door window balcony and boundary detectors of the alarm system while prevent from triggering the indoor detectors which may cause improper warning then you shall select Arm at Home let just part of the detectors work and disable the other parts Main Unit Operation Press At Home button on keypad Remote Control Operation Pr
9. e main unit will be in disarm status Alarming Record Checking In disarm state input 0 then the main unit will make a long beep and enters the state of alarm record checking After displaying the alarm and defense zone number indicator the LCD screen will display the exact alarming time of this defense zone Press 2 you can upturn to check the previous alarming record press 8 downturn to check and press to exit checking For example the 51st defense zone the 7th alarming alarming time 12 10 August Ist 2008 LCE display for one second and then ALARM SYSTEM V1 0 1 l J display the alarming time L _ GSM Signal Checking Before installing the main unit you should check the signal of the installing place in order to ensure the unit can perform well In setup state input 81 gt the main unit will make a long beep and display 00 XX XX indicates the intensity of the signal And the intensity should be within the range of 07 31 if it s less than 07 you should change place For example if the signal intensity is 12 it will display as Maintenance el System Checking Although the alarm system is used everyday periodical maintenance and test are required to assure that it can run stably reliably and safely Usually thorough test must be performed on the alarm main unit every three months You d better check the detector once a month if not permitted by cond
10. ective effective real time Window alarm yes Zone 4 effective effective real time Balcony alarm yes Zone 5 effective effective 24 hours Fire alarm yes Zone 6 effective effective 24 hours Gas alarm yes Emergency effective effective 24 hours Emergency no button alarm o E ALARM SYSTEM V1 0 Zone 7 99 effective invalid real time Emergency yes alarm Wired effective invalid real time Emergency yes defense zone alarm 96 99 Operation Password 8888 Remote control On Remote control Password 1234 Siren Off Siren sound time 180 sec Home Appliance Optional L Components list Main panel 1 pcs Remote controller 2 pcs PIR sensor 1 pcs Door sensor 1 pcs Power adapter 1 pcs User manual 1 pcs 28 ALARM SYSTEM V1 0 The following sensors can be optional Signal Repeater Glass Sensor Wireless Smoke Detector Wireless keypad Panic Button SY g y y Gas Detector 29 ro Wireless Outdoor Siren with flash S O Remote Controller Wireless Pet Immune PIR Detector ALARM SYSTEM V1 0 Optional sensors detectors are packed separately lt includes remote controllers outdoor siren transmitter wireless PIR wireless gap sensor wireless gas detector wireless smoke detector panic button baluster etc you may buy according your specific requirements Typical house configuration Ta External Sirens de Remote co
11. es a long beep and you will hear coding completed the 8 indicator goes out at the same time Operating method 23 gt XX gt XX indicates 01 99 defense zones number 9 ALARM SYSTEM V1 0 LCD display 8 A m Delete L i In setup state use keypad to input 24 then input the defense zone number you want to delete 01 99 and then input to confirm The main unit emits a long beep and the defense zone indicator flickers once You will hear a voice prompt delete completed Operating method 24 gt XX gt XX indicates 01 99 defense zones number Change Password 1 Change Operation Password Operation password is the password used to disarm or remote control In setup status use keypad to input 30 then input the 4 digit new password and then press to confirm The main unit will make a long beep and you will hear a voice prompt setting completed Operating method 30 gt XXXX gt XXXX indicates the new 4 digit password For example change the system password to 1012 10 ALARM SYSTEM V1 0 Operating method 30 gt 1012 gt LCD display T E E l TH 16 ig l CO AA J 2 Change Program Password Program sword is the password you should input in order to setup the system In setup status use keypad to input 31 then input the 4 digit new password and then press to confirm The main unit will make a long bee
12. ess ce button on remote controller LCD display E Disarm It means to stop the alarm when the main unit sounds the alarm or make the alarm system in the state of non warning After disarming even if you trigger the detector the main unit would not sound alarm excluding 24 hour defense areas 2 ls ALARM SYSTEM V1 0 Use keypad to input system password then press button Out Home or At Home lights will be off It means set system disarm successfully r Remote Control Operation Press M button on remote controller Main Unit Operation input system password LCD display A m Answer Alarm Call When the main unit sounds alarm it will dial the preset numbers If no one answers the call the system will call the next user number automatically The system will call each preset numbers for 3 times in order If you answer the call you will hear the pre record voice You can set system via your telephone or mobile phone keypad If you hang up directly without answering the call the system will call each preset number for 3 times circularly Press Read the alarm information Press 1 Main unit stops alarming and Arm it stops calling users Press 2 Main unit stops alarming and Disarm it stops calling users Press 3 Siren off and monitors the scene for 30 seconds for continued monitoring 2 ALARM SYSTEM V1 0 press 3 again to monitor for another 30 seconds Press
13. ition you should check it at least 25 ALARM SYSTEM V1 0 every three months Check the main unit i Whether it can arm disarm normally 2 Whether it can dial the number for alarm normally 3 Whether it can receive wireless detectors signal normally 4 Whether the back up battery can work normally Check the wireless detectors 1 Trigger wireless detectors to see if system can alarm normally Z Check all detectors batteries to see if it s in low voltage 3 Check whether wireless detectors can send signal to the main unit normally E Notes Please do not disassemble repair and alter the products without permission or it may cause accidents and faults Do not drop this product on the ground or on hard objects as it may lead to massive impact to cause faults and damages Without approval and consent of relevant authorities please do not set 110 119 or the alarm phone number of police station for this main unit Technical Parameters a List 1 26 ALARM SYSTEM V1 0 Input Voltage Standby Current Alarming Current Wireless Frequency GSM Frequency Back up Battery Siren Volume DC12V 1A lt 55mA lt 450mA 315MHz 2262 4 7MQ 900 1800 1900MHz NEHIAAA 6 DC7 2V 110dB H List2 Defense Alarm Arm Home Arm Type Siren Zone Information Zone 1 effective invalid real time Door alarm yes Zone 2 effective invalid real time Hall alarm yes Zone 3 eff
14. n input defense zone location number 1 8 and then select siren on off 0 1 at last press to confirm You will hear the main unit emit a long beep and a voice prompt setting completed Operating method 60 gt AA gt B gt C gt D gt AA defense zone number 01 99 means zone 1 to zone 99 B defense zone type 1 real time defense zone 2 40 seconds delay defense zone 3 24 hours defense zone 4 bypass defense zone C defense zone location 1 SOS Alarm 2 Fire Alarm 3 Gas Leak Alarm 4 Door Alarm 5 Hall Alarm 6 Window Alarm 7 Balcony Alarm 8 Boundary Alarm D siren ON OFF 0 OFF 1 ON For example set defense zone 12 to be 24 hour fire alarm and siren on Operating method 60 gt 12 gt 3 gt 2 gt 1 gt E Home Arm Defense Zone Setting If you want some detectors work and some do not you can use Home Arm 17 ALARM SYSTEM V1 0 function In setup state use keypad to input 61 then choose the corresponding defense zone number 01 99 then choose Home Arm and then choose whether alarm 0 1 button and finally press to confirm The main unit will make a long beep and a voice prompt setting completed Operating method 61 gt XX gt A gt XX indicates 01 99 is defense zone 1 to defense zone 99 A indicates 0 Home arm but not alarm 1 Home arm and alarm For example set defense zone 11 to be Home arm and alarm Operating meth
15. ntrol Garage Detector Detectors Smoke A i PIR Movement 30
16. od 61 gt 11 gt 1 S H For example set defense zone 12 as Home arm but not alarm Operating method 61 gt 12 gt 0 gt EH Artificial Recording In setup state use keypad to input 701 and then press to confirm The main unit will emit a beep and the LE indicator is on and after 10 seconds countdown recording starts record at 30cm away from the main unit with moderate tone 10 seconds later the main unit will make a beep indicating the recording stops and the recorded voice will replay DER ALARM SYSTEM V1 0 Operating method 701 gt od m Siren Setting LCD display In setup state use keypad to input 75 in the operation of arm disarm by remote control select if the siren sounds or not by 0 1 button and then press to confirm The main unit will emit a long beep and a voice prompt setting completed Operating method 75 gt A gt A indicates 0 Siren off 1 Siren on System default 0 Siren off For example set siren on when arm disarm Operating method 75 gt 1 gt j Y l Joe l l l L LCD display Operation Instructions n System status There are 4 status as following Arm defense zone 1 99 will alarm when detectors are triggered Home Arm in arm status the defense zone which is set as Home Arm will 19 ALARM SYSTEM V1 0 alarm when detectors are triggered Disarm
17. p and you will hear a voice prompt setting completed Operating method 31 gt XXXX gt XXXX indicates the new 4 digit password For example change the system password to 2846 Operating method 31 gt 2846 gt Note the operation password and the programming password LCD display can not be set as the same number 11 ALARM SYSTEM V1 0 m Clock Setting In setup status use keypad to input 32 then input the last 2 digits AA of the present year the two digits BB of the month the two digits CC of the date the two digits DD of the hour 24 hour system the two digits EE of the minute the two digits FF of the second and finally enter to confirm You will hear a long beep and a voice prompt setting completed Operating method 32 gt AA gt BB gt CC gt DD gt EE gt FF gt AA indicates the last 2 digits of the present year BB indicates the 2 digits of the present month CC indicates the 2 digits of the present date DD indicates the 2 digits of the present hour EE indicates the 2 digits of the present minute FF indicates the 2 digits of the present second For example set the time as 15 35 40 Oct Ist 2009 Operating method 32 gt 09 gt 10 gt 01 gt 15 gt 35 gt 40 gt E Timing Settings 1 Timely Arm In setup status use keypad to input 33 35 then input the hour AA and minute BB 12
18. tup state use keypad to input 20 input the remote controller number 1 8 and then press to confirm The main unit emits a long beep and you will hear remote control coding The indicator is on without flashing press any button on the wireless remote controller the main unit makes a long beep and you will hear coding completed 3 indicator goes out indicating the remote controller succeeds in coding Operating method 20 gt A gt A indicates 1 8 remote controllers number You can add maximum 8 remote controllers ALARM SYSTEM V1 0 LCD display 8 I a Delete F i In setup state use keypad to input 21 then input the remote controller number 1 8 and then press to confirm The main unit emits a long beep and the Signal indicator flickers once You will hear a voice prompt delete completed Operating method 21 gt A gt A indicates 1 8 remote controllers number a Coding of Defense Zone Wireless detectors have to be coded to the main unit in order to trigger it alarm In setup state use keypad to input 23 input the defense zone number you want to code 01 99 and then input to confirm The main unit emits a long beep and the corresponding defense zone is displayed on the screen You will hear a voice prompt detector coding Then trigger a wireless detector to emit a wireless signal after receiving the signal the main unit mak
19. umber Setting 14 Notes 26 Delete Phone Numbey 14 Technical Parameters 26 Function Instruction 7 wired and 99 wireless defense zones LCD screen with time clock display Voice prompt for all operations 3 groups of timely arm and disarm Can store 6 phone numbers when alarming system will make alarm call to these numbers automatically Can store 3 SMS numbers when alarming system will send alarming SMS automatically 10 second automatic message recording Built in artificial intelligent digital voice announcer Built in artificial intelligent English message Users can make calls by using keypad on alarm panel just like a telephone One key control function Out Arm Home Arm Remote Arm SOS fire gas door hall window balcony and boundary places alarm Real time delay 24 hours bypass defense zones programming function Wireless coding easy to add additional wireless accessories EP ALARM SYSTEM V1 0 a Remote control Arm Disarm Monitor and Intercom by phone a Built in AAA NI HI rechargeable battery make alarm when power off a Comply with CCC safety standard and GB12663 2001 national standard Alarm Host In order to make the main unit get the wireless signal well for all wireless accessories please put the alarm host at the central place of your defense area Make sure it s away from large metal objects and household appliances which may cause high frequency interference as well

Download Pdf Manuals

image

Related Search

Related Contents

Lite-On 16x8x8x /16x6x4x /5X/16x/ + 48x24x48x Super AllWrite  Blackboard Collaborate IM User's Guide      la sécurité, c`est notre métier  Technologies  Noise in front of printer  Descargar  PROFESSIONAL VACUUM CLEANERS  Progress Lighting P5482-31EB Installation Guide  

Copyright © All rights reserved.
Failed to retrieve file