        DIAL 07M
         Contents
1.                                                   PROGRAMMING        eee andl                                                                  METHODS OF TELEPHONE NUMBER PROGRAMMING       USER PROGRAMMING       cceeeeecseeseeceeeeteeeeeeeeeseseeeeteesaeeeeeeenneaes pa Te 2 222        INSTA ER PROGRA MMN G        Se a ed ee et ee ee eh   TEGHNICAL DATA                 ee ciel Eat eee eee ie yee                  re        alee   DRAWINGS or                           acted                         E A ic                  atom ott mtu recta                                                                             alec                  ROGER s c  DIAL 07M v1 1 29 03 2000  INTRODUCTION    Construction and Use of Dialer   The Automatic Telephone Alarm Dialer is a device used for an automatic transfer of information on an occurrence of an alarm situation  fire  burglary   etc    The DIALO7M dialer is capable of transmitting a verbal message up to eight telephone subscribers and a text message up to two pager system  subscribers  All device operation configuring parameters and verbal alarm message are stored in EEPROM type memories and are not lost at a power  supply loss     DIAL 07M enables   recording a 15 second verbal alarm message   recording of two additional verbal messages about state of A3 control input   notification of up to eight telephone subscribers   notification of up to two pager subscribers   tone  DTMF  and decade  PULSE  dialing   dialer connection by use of ext
2.       Middle letter  V   Right letter            0   Installer Code       Entrance to installer programming mode  After the command is entered  the dialer goes to the installer programming mode  The mode is signalized by the LED PROGRAM  and TEST  indicators  which are on  The dialer configuration parameters are set up in the installer programming mode               Exit from programming mode  After entering the command  the dialer exits the user programming mode and enters the monitoring mode     ROGER s c  DIAL 07M v1 1 29 03 2000  INSTALLER PROGRAMMING    In this mode  the dialer configuration is set up  The installer programming mode is entered exclusively from the user programming mode and is  performed after entering the command      0   Installer code       After entering the mode  the dialer turns on the PROGRAM  and TEST  LED  indicators  The following functions are available in the installer programming mode      1 1    0        A1 input type  The letter  N  should be replaced by entering the digit  1   2   4  or  8   After entering the function  the LED indicator  which corresponds the current  active option  is on  The programmer  by depressing the suitable key  1 2 4 or 8  performs the option change  After switching on the new option  the  corresponding LED indicator is automatically turned on  The exit from the function and entering the changes to the memory is performed by  depressing the key      The options mean as follows     1   NO SLOW type line    2   NC 
3.       Programming of pager system telephone numbers   The character  N  should be overwritten with the digit  1  or  2  depending on that whether the first or the second pager system subscriber telephone  number should be programmed  Each entered digit or character are presented by the LED indicators in the HEX system  Removing a number from  the list is performed by programming the number as a blank one     Example     16  21 12345678        programs the second number to a pager system subscriber       6  1         erased the first number to a pager system subscriber           7   New main code        New main code          Programming of main code    After depressing the key  7   the programmer has to make a double entry of the new main code  Each time the new code has to be ended with the  character      When the two codes are identical  the new code is stored in the memory  otherwise a programming error is signalized and the function  is abandoned  The code length must stay within the range from 4 to 8 digits  The digits of the entered code are displayed by the LED indicators in the  HEX system     ROGER s c  DIAL 07M v1 1 29 03 2000    Example    P7712 12  4   1212         programs the main code as 1212  PY7  12123     12123         programs the main code as 12123   P7  121234     121234         programs the main code as 121234   71112123434      12123434         programs the main code as 12123434         8   New user code       New user code      Programming of user cod
4.       SLOW        line type        SLOW   Alarm delay on A1 input  0 seconds   Dialing options 1 DT signal waiting time 4 sec   Don   t dial the number when no DT   Dialing options 2 Pulse dialing  PULSE    Detect telephone pick up   Number of external rings  0  function off    Double call function time  0 minutes  function off            triggered    message  no message      A3 normal    message  no message   Alarm message  no Message   Text message to PAGER system station  no message   User code 1111   Main code  0000   Installer code 1234             Acoustic signals  During the dialer operation the following acoustic signals can occur     NAME OF SIGNAL sia OF   INTERPRETATION OF SIGNAL    One long signal lasting about 2 sec  Occurrence of the signal informs about a programming  Error signal   error or performing an invalid operation  The signal occurs also after entering the wrong code   Two long signals  The signal occurs at an attempt of programming a code  which is identical    Error signal     identical codes            signal     id with the previously programmed one     Two series of two short signals each  The encourage signal informs that the dialer awaits  entering a further part of a command or code   recognized and performed the entered command        ROGER s c  DIAL 07M v1 1 29 03 2000       Hexadecimal notation system  With reference to some functions of the device  the HEXADECIMAL notation system  HEX in short  is used  In the system  a number can be  repre
5.   CONDENSER      ge 8  0 10   MIKCOPHONE      TAMPER ee SE   amp   ge 16 1   _                  o 2 EE                                                DEVICES CONNECTED  TO TELEPHONE LINE    TELEPHONE LINE  View of DO7M type dialer electronic system board    from microprocessor    BC846B system    PGM1  PGM2       07   4 DO7M       A1  A2  A3 ALARM INPUT STRUCTURE PGM1  PGM2 OUTPUT STRUCTURE     12      
6.  bigger than zero   The  Double Call function is disabled through programming the delay at 000           Note  Please remember that the Double Call function can operate properly only if any other devices  which use the telephone line along with the  dialer  do not intercept a call after recognition of less than two rings  because it would disable the dialer to intercept the call           EE    ROGER s c  DIAL 07M v1 1 29 03 2000    DIALER CODES   The dialer is provided with the following codes   e Main code  MC       User code  UC       Installer code  IC      Each of the codes can have the length from 4 to 8 digits  The main code enables resetting the alarm and entrance to the user programming mode   The user code enables only resetting the alarm  The installer code enables entrance to the installer programming mode        Note     The codes must be different  The dialer does not allow programming of two identical codes  In case of an attempt of programming a code identical  with another  already existing code  the dialer signalizes the code programming error  error signal                 PROGRAMMING    The dialer is provided with two programming modes   User Programming  mode and  Installer Programming  mode  The  User Programming  mode  can be accessed from the READY or ALARM mode using the command  Main Code           The  Installer Programming  mode can be accessed  only from the user programming mode using the command      0   Installer Code          Note   In either o
7.  recorded message is too silent or is significantly distorted  the recording should be repeated and the programmer should speak louder           0   New Installer code        New Installer code          Programming of new Installer code    After depressing the key  0   operator has to make a double entry of the new installer code  Each time the new code has to be ended with the  character      When the two codes are identical  the new code is stored in the memory  otherwise a programming error is signalized and the function  is abandoned  The code length must stay within the range from 4 to 8 digits  The digits of the entered code are displayed by the LED indicators               Exit from installer programming mode  After entering the command  the dialer abandons the installer programming mode and goes to the monitoring mode      11     ROGER s c  DIAL 07M v1 1 29 03 2000    TECHNICAL DATA                     Power supply voltage 11  15 Vde   Supply current typical 40mA   max 100mA   Operating temperature range 0  50 C     Weight approx  0 27 kg   Dimensions  L x W x H  215 x 95 x 27   DRAWINGS  DELAY   ADDITIONAL TERMINAL  ALARM INPUT   OF POWER SUPPLY MINUS    GND    INSTANT ALARM      TELEPHONE LINE VOLTAGE  INPUT  H24 TYPE  LOSS SIGNALLING OUTPUT  CONTROL ALARM SIGNALLING  INPUT OUTPUT       NC TYPE TAMPER   DIALER POWER SUPPLY  PROTECTION CONNECTOR   11   15 VDC                  EEPROM MEMORY      3 5mm MINI JACK RESET JUMPER  HEADPHONE OUTPUT                           
8. AUTOMATIC TELEPHONE ALARM DIALER    DIAL 07M    OPERATION AND INSTALLATION INSTRUCTION MANUAL        9   9  roger    ROGER s c  DIAL 07M v1 1 29 03 2000    TABLE OF CONTENT                                            CONTENT  4 2 2  ett 2           ek cece                   INTRODUCTION vel  Construction and Use of Dialer        INSTALLATION OF DIALER         CONNECTION  OF DOWSI SUDDIY cass              Connection of telephone line  an  Connection of input                                              Connection of PGM1 and PGM2 output lines  Switching on power supply voltage   EEPROM memory resetting  Default  manufacturing  settings of EEPROM memory  Detault  SOttings               crag                       Acoustic signals     Hexadecimal notation system  LED indicators                        ee  LED indicator       TEL                                   PREPARATION FOR DIALER OPERATION      DIALER OPERATION                                        READY mode            ALARM mode               wk  ALARM RESETTING ee  NOTIFICATION WITH AN ALARM MESSAGE    PROCESS OF TELEPHONE CONNECTION          bugs    25 aie 0  DETECTION OF PHONE  PICK UP 2 4 00         a ee               ae el         DISABLING DETECTION OF PHONE PICK UP      BLIND  TRANSMISSION OF ALARM MESSAGE  CALLING DIALER FROM OUTSIDE  DOUBLE CALL FUNCTION nas                   ae oe  DIALER   CODES                        drag TONDEIRE DE ented Patan saben cn erin onde an dah eons aan  Aad diene aint en vind         
9. SION OF ALARM MESSAGE   In justified cases  during the dialer configuration  the installer can switch off option  Don t detect phone pick up    Enabling the option results in an  unconditional transmission of the alarm message directly after dialing the telephone number  When the option is on  the dialer recognizes each  attempt of    telephone connection as    notification  When the option is on  the dialer dials each of the pre programmed alarm numbers twice no  matter if the subscriber has or has not picked up the phone           Note  When the option  Don t detect phone pick up  is on  it is recommended to program the same telephone number in two or more positions to  enhance the notification certainty     CALLING DIALER FROM OUTSIDE   The dialer is capable of accept the phone calls from outside  During the configuration  the installer defines the number of rings  after recognition of  which the dialer has to start handling an external telephone call   See the Installer Programming function     7    The dialer  after recognition of the  required number of rings  switches into the telephone line and transmits a verbal message corresponding to the current condition of A3 line  When A3  is triggered dialer transmit message    A3 triggered    or when line is in normal condition dialer transmit message    A3 normal     recording of this  messages see function     9  1  and  2  in Installer programming mode   If an alarm occurred during the last READY cycle  the dialer addition
10. SLOW type line    4   NO FAST type line    8   NC FAST type line    Example    J       programs the   1 line as the NC SLOW type line     NOTE   A slow line requires a pulse longer than 2 sec  for triggering  A fast line requires a pulse longer than 0 2 sec       I 2  N         A2 input type  Programming identical as for the A1 input         I 3  N            line type  Programming identical as for the A1 input       1 4  XYZ       Alarm start time delay   The time delay refers only to the A1 input line  The value entered in place of the  XYZ  characters can be from 0 to 255 and means the time delay in  seconds  After entering the function  the PROGRAM LED indicator flushes  The programmer enters digits  each time a subsequent digit is entered  it  is presented by the LED indicators  After entering the third digit  Z   the function should be abandoned by depressing the key      When the value   XYZ   000  is programmed  the alarm is started immediately after recognition of the A1 alarm input triggering     Example      J 4  120       sets the alarm start time delay at 120 seconds      4  012       sets the alarm start time delay at 12 seconds    7 4 727     sets the alarm start time delay at 12 seconds       5            Dialing options 1   When the function is entered  the LED indicator  which corresponds the currently active option  is on  By depressing the proper key  1   2   4  or  8    the programmer selects a new option  After switching on the new option  the correspond
11. alarm mode  the dialer performs telephone connections with the numbers from the alarm telephone list and closes the  PGM1 output for 3 minutes  If the alarm has been started from the dialer keypad through entering the duress command  the PGM1 output  which  normally signalizes the alarm  is not switched on  The duress command is entered by entering the user main code or user code increased or  decreased by  1  in the last position     ROGER s c  DIAL 07M v1 1 29 03 2000    An example of entering the duress command     Main code 1        Main code  1        User code 1        User code  1       All the commands start the operation of the silent telephone notification  i e  with the PGM1 output off     Note  After completion of the telephone notification operation  the dialer automatically returns to the monitoring mode and is ready for new alarm   ALARM RESETTING   Resetting of the alarm results in an interruption of the telephone notification operation and switch off PGM1 output  After the alarm is reset  the  ALARM LED stops flushing  The alarm can be reset from the dialer keypad using the commands  Main Code      or  User Code      or  Main  Code            The latter command  in addition to resetting the alarm  makes the dialer switch to the user programming mode     Note  The dialer allows for three attempts of entering the code  The third failed attempt results in blocking the keypad for 1 minute  During entering  the codes or other keypad manipulations the dialer does n
12. ally to  the messages about A3 line plays the alarm verbal message  the same as during the alarm action  After transmitting the messages  the dialer  automatically disconnects telephone line  Transmission of the    A3 triggered    message is preceded with three long acoustic signals          whereas  transmission of the    A3 normal    message is preceded with a series of three acoustic signals composed of short pulses                   DOUBLE CALL FUNCTION   In case the dialer recognizes in the telephone line the number of rings  which is equal with the number pre declared in the configuration  then no  matter if the Double Call function is on or off  the dialer hooks into the telephone line and handles the call  However  if the recognized number of rings  is smaller than the pre set value in the configuration and the Double Call function is on  the dialer starts the process of counting pre declared time  delay  If  during this delay the dialer recognizes rings again  it does not wait for the required number of rings  but immediately after the second ring  connects into the telephone line and handles the connection  This function enables other devices  which are connected to the telephone line along  with the dialer  the priority access to receive a call and provides that any third parties do not see the presence of the dialer in the telephone line    Note  Enabling of the Double Call function is done through programming the time delay  the Installer Programming     7  value
13. ator       TEL     2  In addition to the mentioned LED indicators  the dialer is also provided with another  fifth  LED indicator  marked with a symbol of the telephone   When the indicator is on  it means that the dialer is in telephone communication process and the telephone line is busy     PREPARATION FOR DIALER OPERATION    In order to prepare the dialer for operation  electric connections should be made and then the installer programming mode should be entered and the  dialer operation configuration parameters should be set  After that  switch to the user programming mode and perform the necessary additional  programming operations     DIALER OPERATION    READY mode   When in the READY mode  the dialer monitors the A1 alarm line and the A2 line  If the triggering condition occurs at the A1 input  dialer start time  delay before alarm and after the time delay has expired enters ALARM mode    Triggering A2 input results in the immediate switching of the dialer to  the alarm mode  The READY mode is indicated by the READY LED indicator  which is on  If the A3 input is in the triggering mode  then the A1 input  monitoring is switched off  Blocking of the A1 line monitoring is indicated by flushing of the READY led  The condition of the A3 line has no effect on  the A2 input monitoring     ALARM mode   The alarm mode is entered as a result of recognition of the A1 or A2 input triggering or it can be performed from the dialer keypad after an duress  command is entered  In the 
14. e  Programming of the user code is carried out in the same manner as programming of the main code          9  Programming of message to pager system   Programming of the message to the pager system is performed by entering a series of characters from the dialer keypad  The entered characters are  transmitted as DTMF digits to a pager system station  Pager system operators use various message coding algorithms  Coding of the message to the  pager system station should be performed according to the system operator manual  treating the dialer keypad in the same way as the telephone  keypad  The method of message programming compliant with the POLPAGER system is presented below             switches the keypad to the letter mode            return from the letter mode to the digital mode                 in the letter mode it gets the left letter of the keypad                the letter mode it gets the right letter of the keypad    N    in the letter mode it gets the middle letter of the keypad          enters a space in the digital mode     0    enters a space in the letter mode     O          the message end      the letter mode          the message end in the digital mode     After entering the function  the keypad operates in the digital character entry mode  The message can consist of maximum 128 characters   ABC DEF    D a    GHI JKL MNO    PRS TUV WXY     7   5   5     b               ARRANGEMENT OF LETTERS ON DO7M DIALER KEYPAD                  Left letter  for example where
15. e should be connected to the dialer terminals marked with the caption  LINE   Other devices  which use the telephone line  should be  connected to the terminals  TEL   Such a connection guarantees that the devices connected to the terminals  TEL  cannot disturb the dialer when  operating with telephone line  The other devices  fax  modem etc   using the telephone line can be also connected parallel with the dialer  i e  to the  terminals  LINE   but in this case they can disturb or even stop the dialing and alarm notification process     Connection of input lines   There are three inputs of the dialer  A1  A2 and A3  The A1 and A2 inputs are the alarm inputs  Input A3 has control function and can stop the alarm  and disabling monitoring of A1 line  All the dialer inputs have identical electric structure  Each of them can be configured as NO or NC  The alarm  inputs are usually triggered with a contact  but it can be also triggered through supplying a suitable voltage level  The line programmed as NO can be  triggered by supplying the power supply  minus  or by using NO switch  Line configured as NC can be triggered by using NC switch or by supplying  the power supply  plus   however when triggering by supply    plus    input should be previously connected with ground     supply minus     by a resistor  within the range from 0 5 to 2KQ     47 input  Delay alarm input  Triggering the input results in switching of the dialer into the alarm mode after the alarm time delay   Monit
16. ernal call function   monitoring of telephone line voltage and signalization of a voltage loss     DIAL 07M is provided with   main code enabling alarm resetting and device programming   user code enabling only alarm resetting   installer code enabling dialer configuring   delay alarm input  A1 line    instant alarm input of H24 type  A2 line    control input  A3 line    alarm signaling output  PGM1    telephone line voltage loss signaling output  PGM2    built in capacitive microphone   stereo mini jack output for messages reproducing and listening to the telephone line     INSTALLATION OF DIALER    The dialer should be hung on a vertical structure element  wall   far from any heat and moisture sources  All electric connections should be made prior  to power supply connection  After programming of the dialer  it is recommended to perform an alarm action simulation and check the notification  efficiency in practice     Connection of power supply  The dialer power supply cables should be connected to terminals marked with     12Vdc  The dialer requires DC power supply within a range from 11  to 15         The dialer power supply system is protected with a polymer type electronic circuit breaker and does not need to be replaced after fault  condition  After the dialer is connected to power supply for the first time  it operates using the default  manufacturing  configuration settings  without  the recorded verbal messages           Connection of telephone line   A telephone lin
17. f the programming modes the dialer does not monitor the input lines nor answers external calls     METHODS OF TELEPHONE NUMBER PROGRAMMING  The dialer enables programming two telephone numbers to PAGER system stations and eight alarm numbers to subscribers notified with a verbal  alarm message  Each number can consist of 16 digits  In addition to the digits 0  1  9  some special characters can be inserted in a telephone  number  The dialer accepts the following special characters     CHARACTER PROGRAMMING STATUS  This character is used for switching to another  alternate  dialing  HEXB ial     system  i e  from DTMF to PULSE or inversely     This character introduces a 4 second interruption in dialing  After  The character makes the dialer wait for a dial tone  DT  signal     Programming the character results in stopping the dialing process  until a DT signal occurs     HEX D                                    the break has elapsed  the dialer resumes dialing                                    ROGER s c  DIAL 07M v1 1 29 03 2000  USER PROGRAMMING    The user programming mode is entered from the monitoring mode or alarm mode using the command    Main Code         After the mode has been entered  the dialer turns on the PROGRAM LED  The following functions are available in the user programming mode           1         Technical problem read out   After entering the function      1    the dialer signalizes the existence of recognized technical problems through turning on the cor
18. ged as soon as the dialer receives a signal  which confirms the receipt of the text message transmitted by a pager  system station                 PROCESS OF TELEPHONE CONNECTION   After connecting into the telephone line  the dialer awaits an answer signal from a telephone exchange  DT  and when the signal has been recognized   the dialer starts to dial the number  After dialing  the dialer awaits an answer  phone pick up  of the dialed subscriber and after that performs a double  transmission of the alarm message and goes to a connection with another alarm number  The maximum time of waiting for dial tone of a telephone  exchange  DT  is set up in the Installer Programming  function     5   and can be set at 4 or 8 sec  When      the required time of 4 or 8 sec  the dial  tone has not been recognized  the dialer goes to dialing another telephone number  If the option  Dial the number despite no DT signal  is activated   the dialer ignores the lack of dial tone signal and despite of it dials a phone number and transmit message     DETECTION OF PHONE PICK UP   Dialer detects phone pick up of dialed subscriber after     disappearance of    returned call signal    or     voltage polarity change in telephone line    Note  A telephone connection  in which an answer of the called subscriber has been recognized by one of the above described manner  is qualified  as successful and the subscriber as having been notified once     DISABLING DETECTION OF PHONE PICK UP    BLIND  TRANSMIS
19. ing LED indicator is automatically turned on  The exit from the  function and storing the changes in the memory is performed by depressing the key      The options mean as follows           DT signal waiting time 4 sec   Don   t dial the number when no DT    2    DT signal waiting time 8 sec   Don   t dial the number when no DT    4    DT signal waiting time 4 sec   Dial the number if no DT    8    DT signal waiting time 8 sec   Dial the number if no DT     DT    Dial Tone    Example       S  4     sets the DT signal waiting time at 4 sec  and makes the dialer select the telephone number and transmit the message  despite the lack of  the signal         6  N       Dialing options 2   When the function is entered  the LED indicator  which corresponds the currently active option  is on  By depressing the proper key  1   2   4  or  8    the programmer selects a new option  After switching on the new option  the corresponding LED indicator is automatically turned on  The exit from the  function and storing the changes in the memory is performed by depressing the key      The  N  digit means as follows      1    Pulse dialing  PULSE    Detect phone pick up      2    Pulse dialing  PULSE    Don t detect phone pick up    4    Tone dialing  DTMF    Detect phone pick up     8    Tone dialing  DTMF    Don   t detect phone pick up      Example     J 6  4     switches to the tone  DTMF  dialing system and sets detect telephone pick up option on                          Number of rings bef
20. o get priority to answer an external call  When the  function is used  it is recommended to set the Double Call time value at a number from 30 to 180 seconds     Example        8  045       sets the DC function activation time at 45 seconds    7          57    sets the DC function activation time at 45 seconds       8  5       sets the DC function activation time at 5 seconds         9  1      Recording message         normal      Immediately after depressing the key  1   the dialer starts to record the message  The message should be recorded by speaking from the distance of  about 20 cm towards the dialer keypad  After the recording time  2 seconds  has expired  the dialer automatically plays back the message  Due to a  short time of recording  2 sec    it is necessary to keep the message short  e g   MONITORING ENABLE    or  MONITORING ON     In case the  recorded message is too silent or is significantly distorted  the recording should be repeated and the programmer should speak louder         9  2    Recording message         triggered      Immediately after depressing the key  2   the dialer starts to record the message  The message should be recorded by speaking from the distance of  about 20 cm towards the dialer keypad  After the recording time  2 seconds  has expired  the dialer automatically plays back the message  Due to a  short time of recording  2           it is necessary to keep the message short  e g   MONITORING DISABLE    or  MONITORING OFF     In case the 
21. ore answer   The letter  N  should be replaced by entering a digit from the range from 0 to 9  After the function is entered  the PROGRAM  LED indicator pulses   The programmer enters the desired parameter value in place of the letter  N   the value is automatically displayed by the LED indicators  The exit from  the function and the entry of the changes into the memory is obtained by depressing the key      When the value N 0 is programmed  the dialer does  not answer any external calls    Example        7  4     sets the external call answering to activate after recognition of four rings      10     ROGER s c  DIAL 07M v1 1 29 03 2000        8  XYZ       Double call function time   The value entered in place of the characters  XYZ  must stay within the range from 0 to 255  seconds   After entering the function  the PROGRAM   LED indicator pulses  The programmer enters the value  XYZ   each time a subsequent digit is entered  the dialer presents it on the LED indicators in  the HEX system  After entering the third digit  Z   the function is abandoned by depressing the key      When the value  XYZ   000  is programmed   the Double Call function is disabled  which means that each time when the dialer recognizes the pre programmed number of rings  it hooks into the  telephone line and transmits a message on the dialer status and  if applicable  occurrence of the alarm     Note   The double call function allows other devices  which use the telephone line along with the dialer  t
22. oring of the A1 input does not operate when the dialer is in the programming mode or when the A3 line is triggered     A2 input  Instant alarm input  Triggering this input starts alarm without any delay  The dialer monitors the input regardless the condition of  the A3 line  Monitoring of the A2 line does not operate in the programming modes          input  Controls monitoring of 47 input and can stop the alarm  When      is triggered monitoring of 47 line is switch off  Momentary  triggering of the A3 input during an alarm results in the alarm reset     Connection of PGM1 and PGM2 output lines   The outputs are the  open collector  type universal outputs of 1A dc current capacity  The outputs are normally opened  which corresponds the high  impedance condition   When closed  the outputs supply the power supply  minus  potential  A maximum potential of  24V against the dialer power  supply  minus  can be connected to the programmable output  The programmable outputs are protected from overvoltage and are capable  without  any additional control elements  relays   of controlling the switching of most popular types of alarm signaling devices     PGM1 output  The output goes to ON state each time the dialer starts alarm  The output returns to OFF state after three minutes or after  alarm is reset  cancel   When the alarm has been switched on by entering a duress command  the PGM1 output is not closed   the duress command     see the  ALARM  Mode section      ROGER s c  DIAL 07M 
23. ot interrupt the telephone notification operation nor stops the alarm input monitoring     Important   Resetting the alarm can be performed from    remote location through a momentary or permanent triggering of the      line        NOTIFICATION WITH AN ALARM MESSAGE   The dialer try to get a double connection with each of the pre programmed telephone subscribers specified in the alarm list  A telephone connection is  qualified as a  notification   if the dialer  based on an analysis of electric signals in the telephone line  recognizes the moment of phone pick up by  the called subscriber and performs    transmission of the alarm message  If option  Don t detect for telephone pick up   Installer Programming  function     6    each dial attempt is treated as a notification  no matter if the subscriber has or has not picked up the phone  Telephone connections  are performed in four dialing cycles  In each dialing cycle the dialer performs one attempt with every telephone number  The telephone connections  are performed according to their sequence on the telephone list  The subscribers  who have receive twice notification are skipped during the further  notification process  The pager system subscribers are selected as the first priority  i e  prior to the numbers of the subscribers notified with a verbal  message  A text message  see the User Programming function     9   is transmitted to the pager system subscribers  A notification to the pager  system subscribers is acknowled
24. r code or triggering the A3 line        The dialer is now counting time delay before alarm mode  Resetting the alarm during the delay  protects from commencing the telephone notification action and alarm signaling at the PGM1  output     ALARM and READY are on       PROGRAM  LED is on The dialer is in the user programming mode        TEST LED is on The dialer has recognized an occurrence of at least one technical problem        Since the time of the latest read out of the technical problem       1 function   the dialer has    TESTES D        recognized a new technical problem           PROGRAM  and TEST LED are on The dialer is in the configuration mode              LLOG O00  C008                                         In the programming mode  the LED indicators are additionally used for visualization of the entered parameter values  The LED indicators are assigned  with the numbers 1 2 4 and 8  Reading of the HEX number  which is displayed by the LED indicators  is obtained by adding the numbers located next  to the active LED indicators  The  zero  digit is indicated by flushing of all the LED indicators     An example of reading of a number value indicated in the HEX code   PROGRAM   4  and TEST  8  indicators are on        B                  The number 8 corresponds the TEST indicator and the number 4 corresponds the PROGRAM indicator  The value of the presented HEX number is  therefore 8 4 12  which should be interpreted as the number  C  in the HEX system     LED indic
25. responding LED  indicators  A return from the function is done by depressing the key         PROBLEM CODE   METHOD OF LED MEANING OF PROBLEM  INDICATOR  PRESENTATION    A telephone line voltage loss  The problem disappears when the telephone line voltage is back   Recognition of the error is additionally signalized on PGM2 output     A telephone exchange does not respond  no DT signal   The problem disappears as soon as a  DT signal occurs at the next telephone connection     This problem indicates that some errors in the data memory  EEPROM  occurs  In consequence   the dialer malfunctions may occur  In order to solve the problem  the EEPROM memory should be  reset and the dialer should be programmed again  If reprogramming does not solve the problem   the dialer should be returned to the service for repair     The problem indicates an error in the program memory  ROM   If such a problem is found  the  dialer should be returned to the service for replacement of the ROM memory system              2   N   Telephone number        Programming of N th alarm number   In place of the letter N  enter a digit from 1 to 8  which determines which of the numbers will be programmed  The number programming completion is  obtained with the character      Each entered digit or special character is presented on the LED indicators in the HEX system  A number is deleted  from the alarm telephone list by programming it as a blank number     Example       2  411234566789       the fourth alarm n
26. sented as a digit from the range 0 1   9 or a letter A  B  C  D  E and F  The number interpretation and programming methods in the HEX system  are shown in the following table     NUMBER IN DECIMAL NUMBER IN PROGRAMMING METHOD  SYSTEM HEXADECIMAL SYSTEM KEYS LED INDICATOR PRESENTATION METHOD                       01      PINI         51     The drawing symbolizes all LED indicators are flashing                m      a        B                                              a  BS  m                5                                                  3        B   m                                                  lt                          zerr    ROGER s c  DIAL 07M v1 1 29 03 2000    LED indicators    The dialer is provided with five LED indicators  four of which are used for indication of the dialer operation status or are used during programming   The names of the indicators are   ALARM  1     READY  2    PROGRAM   4  and  TEST  8   The digits next to the LED indicators enable easy  interpretation of the numbers in the HEX system     The method of interpretation of the LED indicator status is as follows        ALARM LED is on The dialer is in the alarm mode        READY LED is on The dialer monitors the A1 and A2 alarm inputs        READY LED flushes The      line is triggered  the dialer monitors only the A2 line  monitoring of the A1 line is off        The dialer has been in the alarm mode and the alarm has not been reset yet by either entering the    ALARM TED flushes prope
27. umber is programmed      2     7       the fourth alarm number is erased    J 2  N       the N th alarm telephone number   N  1  8          3   N                   Read out of N th alarm number   After entering the function  the LED indicators present the first digit of the telephone number in the HEX system  The key     provides a skip to the  presentation of the next digit of the number  The function is abandoned automatically after the last digit of the telephone number is displayed or may  occur earlier after using the key               4            Recording of alarm message   Immediately after depressing the key  4   the dialer begins recording of an alarm message  The message should be recorded by speaking from a  distance of about 20 cm from the dialer keypad  The message recording is completed and the function is abandoned when the available recording  time  15 sec   has elapsed or it can occur earlier  after depressing the key              5            Playback of alarm message   Immediately after depressing the key  5   the dialer begins to play back the alarm message recorded in the memory  The message can be listened to  using a set of headphones plugged into the dialer headphone output  The headphones need to be equipped with a  mini jack stereo  of 3 5 mm  diameter  The end of playback and exit from the function is performed automatically after playing back the complete message or may occur in any  moment by using the key               6  N   Telephone number  
28. v1 1 29 03 2000    PGM2 output  The output is switched ON when the dialer recognizes a 3 minutes lack of telephone line voltage  The output returns to OFF  state as soon as the telephone line voltage returns     Switching on power supply voltage   EEPROM memory resetting   Each time after switching the power supply on  the dialer tests the position of the Z1 jumper  In case it is in the EEPROM RESET position  the dialer  resets all current settings in the EEPROM memory and assigns them the default  manufacturing  values  then the dialer goes to the READY moce  If   during switching the power supply on  the Z1 jumper is in the NORMAL POSITION  the dialer skips the process of the EEPROM memory resetting     Note   After resetting the EEPROM memory  the Z1 jumper should be returned to the DEFAULT POSITION     Default  manufacturing  settings of EEPROM memory   During the manufacturing process of the dialer  a set of parameters  whose name is default  manufacturing  settings  is entered into the EEPROM  memory  The settings are modified in the dialer programming or configuration process  The default values can be returned any number of times by  performing the EEPROM memory resetting procedure  EEPROM memory is usually reset in case of a loss of the previously programmed dialer  codes or in order to fix the technical trouble called  EEPROM memory error        Default settings                                                                  1 line type        SLOW   A2 line type  
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  ezConfig User's Manual  Instructions: PolyPRO 3™ 5th Wheel Cover  handleiding nassau 2008.indd  Cambridge Audio Topaz AM5  Revue de presse Salon Osez nos compétences IDF  Guide de dépannage et de maintenance - Hewlett  Actuadores de fracción de vuelta SQ 05.2 – SQ 14.2/SQR 05.2  delfi pro delos pro santorini pro  USER GUIDE - notices patrick modélisme    Copyright © All rights reserved. 