Home
ST60-DVC ST60-AG57
Contents
1. 12843 Foothill Bivd Suite D Sylmar CA 91342 818 898 3380 voice 818 898 3360 fax www dnfcontrols com ST60 DVC VTR CONTROLLER ST60 AG57 VTR CONTROLLER USER MANUAL Manual Version 2 1 122203 Document ID ST60 DVC_User_Manual doc 1 ST60 DVCPRO 1 REVISION HISTORY 122203 Rev 2 1 Company header information revised Added DNF Controls Limited Warranty 2 ST60 DVCPRO THE ST60 DVC VTR CONTROLLER The ST60 DVC VTR Controller is ideal for Television Stations Cable TV Video Production Video Post production Audio Post production Duplication Houses and Corporate Video Facilities STANDARD FUNCTIONS RECORD REWIND PLAY FAST FORWARD STOP EJECT REAL TIME STATUS INDICATORS ACTIVE ON RECORD REWIND REVERSE PLAY FAST FORWARD FORWARD STOP STILL 2 INSTALLATION a Set the VTR s Data transfer rate to 9600 baud No Parity 8 bits 1 stop bit Set ACK RETURN to off See the DVCPRO User s Manual b Plug the 9 pin connector end of an RS232 serial cable in to the 9 pin female connector on the rear of the ST60 Plug the 25 pin connector end of the same cable into the 25 pin female RS232 C remote connector on the rear of the VTR See wiring information below c Plug the POWER SUPPLY s 9 pin connector into the 9 pin male connector POWER on the rear of the ST60 Plug the other end of the POWER SUPPLY into 90 VAC to 265 VAC d Select REMOTE operation
2. THRU 2 STOP lt REWIND Switch Input Connector Dry SPST contact closure momentary Status Output Open collector 50 ma sink TE FFWD 9 Pin Remote lt JOG OPTIONAL KEYPAD PROVIDED BY USER 5 ST60 DVCPRO 6 SPECIFICATIONS Front Panel 6 Status LEDs Record Play Stop Rewind Fast Forward 1 Power LED Size 7 x 5 x 1 1 2 female Weight 2 165 Rear Panel RS 422 Serial Output 9 Pin D type connector female DB9F Power 9VDC 500 mA 100 265 VAC 50 60 Hz Record Selector 6 pole dip switch Keypad Interface 15 Pin D type connector Female DB15F Switch Input dry SPST momentary contact closure POWER SUPPLY CONNECTOR 9 Pin D Type Male DB9M Pin 1 5Vde Pin 6 2 5Vde 7 3 Ground 8 4 9 5 6 ST60 DVCPRO 5Vdc Ground Ground Ground ST60 GPI In Out CONNECTOR 15 Pin D Type Female DB15F PIN FUNCTION 1 5v DC 2 SHIFT Switch Active Low 3 Record Tally Actvie Low Open Collector 4 Play Tally Actvie Low Open Collector 5 Stop Still Tally Actvie Low Open Collector 6 Rewind Reverse Tally Actvie Low Open Collector 7 Fast Forward Forward Tally Actvie Low Open Collector 8 No Connection 9 Command Common 10 Record Command Active Low 11 Play Command Active Low 12 Stop Command Active Low 13 Rewind Command Active Low 14 Fast Forward Command Active Low 15 No Connection NOTE There are no internal current limiting r
3. esistors for the open collector status indicator drives A 62 ohm resistor in series with the 9 volt D C power supply is recommended for LEDs Limit lamp current to 50 ma at 9 volts D C VTR Connector RS232 Serial Interface 9 Pin D Type Female DB9F Pin 1 Not Used 2 Receive Data 3 Transmit Data 4 Not Used 5 Ground 6 Not Used 7 Not Used 8 Not Used 9 Not Used 7 ST60 DVCPRO DVCPRO VTR 25 Pin D Type Female DB25F 1 Not Used 2 Receive Data 3 Transmit Data 4 Not Used 5 Ground 6 Not Used 7 Signal Ground 8 25 Not Used AG5710 VTR 25 Pin D Type Female DB25F 1 Not Used 2 Receive Data 3 Transmit Data 4 RTS 5 CTS 6 DTR 7 Signal Ground 8 Not Used 9 Not Used 10 Not Used 11 Not Used 12 Not Used 13 Not Used 14 Not Used 15 Not Used 16 Not Used 17 Not Used 18 Not Used 19 Not Used 20 DSR 21 Not Used 22 Not Used 23 Not Used 24 Not Used 25 Not Used You must wire the 25 pin connector at the VTR as follows Jumper Pins 4 and 5 together Jumper Pins 6 and 20 together 8 ST60 DVCPRO 7 DNF CONTROLS LIMITED WARRANTY DNF Controls warrants its product to be free from defects in material and workmanship for a period of one 1 year from the date of sale to the original purchaser from DNF Controls In order to enforce the rights under this warranty the customer must first contact DNF s Customer Support Department to afford the opportunity of identifying and fixing the problem without
4. on the VTR s front panel Set the RECORD SELECTOR SWITCHES located on the rear panel of the S60 to the desired record mode per the RECORD SELECTOR CHART f Set Dip Switch 6 on the rear panel as follows ON 230 5710 OFF AJ D750 AJ D640 amp all others Installation is completed 3 ST60 DVCPRO 3 OPERATION Select the desired transport function by pressing the appropriate switch on the front of the ST60 The Real Time Status Indicators will light to indicate the VTR s current tape transport mode For example Pressing PLAY will put the VTR into the PLAY mode PLAY Status Indicator will light when the VTR is in PLAY mode The real time Tape Counter is displayed on the LCD Display Loss of serial communication with the VTR is indicated by ALL Status LEDs turned ON 4 RECORD MODE Two 2 Record modes are available Crash Record Full Record and Record Lockout Press only the RECORD switch to activate the selected Record mode The Record Status Indicator will turn on when the VTR begins recording NOTE The VTR will not go into Record mode if Record Inhibit is enabled on the VTR or tape cassette 5 RECORD SELECTOR SWITCHES Mode 51 52 5 54 5 56 Record Lockout OFF OFF OFF OFF OFF OFF Full Record OFF ON OFF OFF OFF OFF 4 ST60 DVCPRO Connection Diagram 5 VDC 1 ER Ed Parallel Machine Control System Master Control Switcher Control Panel VTR E 100
5. sending the unit in for repair If DNF s Customer Support Department cannot fix the problem the customer will be issued a Returned Merchandise Authorization number RMA The customer will then ship the defective product prepaid to DNF Controls with the RMA number clearly indicated on the customer s shipping document The merchandise is to be shipped to DNF Controls 12843 Foothill Blvd Suite D Sylmar CA 91342 USA Failure to obtain a proper RMA number prior to returning the product may result in the return not being accepted or in a charge for the required repair DNF Controls at its option will repair or replace the defective unit DNF Controls will return the unit prepaid to the customer The method of shipment is at the discretion of DNF Controls principally UPS Ground for shipments within the United States of America Shipments to international customers will be sent via air Should a customer require the product to be returned in a more expeditious manner the return shipment will be billed to their freight account This warranty will be considered null and void if accident misuse abuse improper line voltage fire water lightning or other acts of God damaged the product All repair parts are to be supplied by DNF Controls either directly or through its authorized dealer network Similarly any repair work not performed by either DNF Controls or its authorized dealer may void the warranty After the warranty period has e
6. xpired DNF Controls offers repair services at prices listed in the DNF Controls Price List DNF Controls reserves the right to refuse repair of any unit outside the warranty period that is deemed non repairable DNF Controls shall not be liable for direct indirect incidental consequential or other types of damage resulting from the use of the product HH 9 ST60 DVCPRO