Home
MusicLab MIDIoverLAN CP Driver
Contents
1. 8 Mountain Lion or 10 9 Mavericks it is highly recommended to update MolCp3 version up to at least 3 3 917 MusicLab doesn t support MolCp3 installed on so called Hacintosh systems Installation If you already have previous version of MolCp3 first of all uninstall previous installation please refer to Uninstallation details If you have previous version of MolCp3 installed please uninstall it see Uninstallation Invoke molcp3 3 3 920 setup exe and follow onscreen instructions 4 On each possible warning screen that driver has not passed Windows Logo testing if any click Continue anyway button 5 Open Configuration Panel Start gt Programs gt MusicLab gt MolCp III Driver 2 Configuration Panel to make change settings E 1 Make sure you re logged on as system admin you should have administrative privileges j 2 3 1 Make sure you re logged on as system admin you should have administrative privileges KM 2 If you have previous version of MolCp3 installed please uninstall it see Uninstallation 3 Invoke MolCp3Installer MolCp3Installer9 for Mac OS X 10 9 package follow onscreen instructions and restart system when prompted 4 Open MolCp3CirlPanel Applications MusicLab MolCp3 MolCp3CtrlPanel to make change settings On how to configure MolCp3 please refer to Configuring the driver article Ka Trial period limitations MolCp3 until registered expires in TWO WEEKS
2. each truck Let s order trucks to be under loading not more than 20 minutes for example since the first item is loaded into each one Moreover you would prefer to upgrade autoloader but your re not its owner and you may not do that however you expect hope some other factories have advanced autoloaders Now delivery efficiency will depend on how many additional items an autoloader can really load into a truck within 20 min interval since first item is loaded Assume this is scenario 2 Now let s go back to MolCp3 however we will revolve our scenario examples In this case a warehouse from example is some sequencer application producing MIDI events home devices are MIDI events trucks network packets and towns other computers While Send Quantization Time parameter is 0 MolCp3 sends MIDI events as your company delivers home devices by scenario 1 i e immediate delivery But we have increased CPU utilization and network resource costs because of one by one MIDI events processing scenario 1 To force MolCp3 to work by scenario 2 let s set Send Quantization Time parameter to little non zero value for example 0 1 ms minimum non zero value Now having 0 1 ms delay MolCp3 is allowed to cache several one by one but tightly produced MIDI events pack them into network packets and then upon expiration of 0 1 ms timer send completed packets Moreover MolCp3 can pack MIDI events from any Network ports to one network packet if al
3. mode to all MOL computers You can also fill out combo box with any name manually However note that if you manually fill out P combo box with incorrect unknown or non existent computer name OUT Network port will send MIDI events in broadcast mode Note MolCp3 computer names are case sensitive In the Target Port up down box you can also specify target Network port number you want to transmit MIDI events to By default Target Port number equals to OUT Network port number Primarily after installation MolCp3 appears as 16 port featured On how to turn it to either 64 port or 128 port mode please refer to Trial period limitations article O Note that OUT Network port CANNOT be configured to send MIDI events to ANY Target Port number On how to use lt Send immediately gt option please refer to Send Quantization article 11 Using OUT Network port test feature Configuring MolCp3 OUT Network port you can test it without necessity to apply settings You can find test button in bottom right corner of MIDI OUT group rectangle Choosing MIDI channel you wish and pressing the button on the right you can easily playback built in chord sequence If MIDI Channel and test buttons are disabled inaccessible even when OUT Network port is enabled it means that MolCp3 doesn t work or works incorrectly Send Quantization Likely Send Quantization Time parameter is the strangest one in MolCp3 Let s try
4. of extra MolCp3 license Then you should install MolCp3 on new computers and register software with new license You can also reregister MolCp3 software to change its property SE to PE and vise versa with any license kind you have see also MolCp3 license protection Uninstallation If your current installed version of MolCp3 is 3 3 0 or higher you could save current settings before uninstallation in order to restore current settings after installation of newer MolCp3 version please refer to Save Load configuration Note MolCp3 version 3 3 0 uninstaller will remove all MolCp3 settings including registration information licence Just run uninstall engine Start gt Programs gt MusicLab gt MolCp III Driver Uninstall 1 Make sure you re logged on as system admin you should have administrative privileges 2 Open Applications MusicLab folder 3 Invoke Terminal utility Applications Utils T erminal 4 Drag Applications MusicLab uninstMolCp3 sh script file into Terminal window and press Enter 5 On Password prompt enter your password and press Enter once again If there are no any error messages it s assumed MolCp3 software was successfully uninstalled Note if you try to invoke uninstall script not having administrative privileges or having entered wrong password MolCp3 software COULD NOT be completely removed from your system Configuring the driver Before start configuring the driver please read this a
5. to preallocate some number of buffers for sending MIDI data allocating buffers during runtime the driver may be forced to wait in MIDIServer context what will indirectly result in kernel panic MolCp3 uses two types of such buffers short up to 170 bytes for MIDI data and long up to 1480 bytes ones Short buffers are used for infodata exchange between MolCp3 computers and also for sending MIDI messages when overall MIDI data size at a time doesn t exceed 170 bytes may include MIDI events coming from any ports to be sent to same target MolCp3 computer Long buffers will be used when overall MIDI data size exceeds 170 bytes Utilization of short buffers inversely depends on Send quantization time and using of Send immediately port mode Consumption of long buffers in this case will be negligible And vise versa When a flow of outgoing MIDI events is high number of preallocated short long buffers buffer pool size may be insufficient flow rate may exceed the rate of buffers return causing another kernel panic In this case the obvious solution is to preallocate as many buffers as possible n However taking in account that MolCp3 borrows buffers from system buffer pool preallocating too many buffers will affect Mac OS X networking functionality what is unacceptable MolCp3 allows to customize number of preallocated buffers specifying the following variables using boot args NVRAM variable Variable name Description Value ran
6. to understand what Send Quantization mechanism is for and how it affects MIDI event stream timing Imagine you re haulier and have infinite number of trucks Your trucks are intended to carry some goods household refrigerators for example from several warehouses Primary scenario of household refrigerators transportation may be as follows An autoloader picks up one refrigerator assume it cannot pick up more than one at a time out of warehouse and loads it into a truck Upon completion loading of one refrigerator a truck driver immediately turns ignition on starts engine and arives one refrigerator to some other location an intermediate storage area While first truck is on its way the autoloader picks up next refrigerator and loads it into another truck which immediately starting its way too and so on Lets complicate scenario assume it s scenario 1 Now trucks will carry 3 kinds of home devices refrigerators laundry washers and dryers from warehouses to several towns optionally A B and C Home devices are loaded into trucks one by one and immediately delivered each by individual truck to towns A B or C Results of your business are very high expenditures very low transportation efficiency BUT IMMEDIATE DELIVERY How to increase delivery efficiency keeping possible minimum delivery delay if your trucks cannot wait until completely loaded as long as you actually don t know whether it s enough items in stock to completely load
7. 07 12 2014 7 uusic LA B gp T MUSIC SOFTWARE DEVELOPERS MusicLab MIDloverLAN CP MIDI Driver MolCp III MIDI Driver for Windows 2K XP Vista 7 8 and MacOS X 10 5 10 6 10 7 10 8 10 9 10 10 Version 3 3 build 920 User s Manual Copyright 2000 2014 MusicLab Inc De Table of contents CONVENTIONS oo c ccc cec cece ccecceucceuceucccuucuucuuucunueuuveuucnuuseuutenttunetuntnettaneennangs Lutte l t e R e EE System Requirements licitis Thal penod ntum MolCp3 license protection sseeeeeeesseseeeeee nnne Registering and upgrading MolCp3 seseeeeesseeeeeee nennen Wigton NOTTE Configuring the driver ssssssssssssssesseen meme memes MolCp3 Network port addressing cccccccssseeecceceeeeecceeeseeecseeeeeessaueeeesseaes Driver s Configuration Panel RE IN Network port configuration scone ctndacsaderncnecesduamesdsusdiaanavarcaereensecien OUT Network port configuration spasst ageseent ENER See Using OUT Network port test feature ssseeeseeeseeeeenennnnn sped mm BE SEC MOERS Appling NAW SNOS Ze EE de EE Load AVS c nfigu ration et feierdeeg e deg ke Target computer list cache eege gieeie er ng dee Ee indus ee eeler EENEG HE dco DOODO EE Contacting MusicLab Installation problems Visibility of MolCp3 ports Malfu
8. AM Network 100Mbps Ethernet compatible interface s MS Internet Explorer 6 0 MS DirectX 9 0 RECOMMENDED MS Windows XP SP2 512 MB RAM Network Gigabit Ethernet compatible interface s MS Internet Explorer 6 0 MS DirectX 9 0c MINIMUM PowerPC G4 or Intel Core Solo based Mac computer Mac OS X 10 5 256 MB RAM Network 100Mbps Ethernet compatible interface RECOMMENDED PowerPC G5 or Intel Core Duo based Mac computer Mac OSX 10 5 2 512 MB RAM Network Gigabit Ethernet compatible interface s MolCp3 can support all network ethernet compatible interfaces installed it really was tested with up to 8 interfaces On how to configure WiFi AirPort wireless interfaces please refer to appropriate documentation However there can be wireless network packet loses while hard traffic via WiFi AirPort particularly resulting in lost hung notes 0 MolCp3 can distinguish up to 4 ethernet compatible interfaces installed into the same remote computer If at least one of your receiving slave computers is running Windows 7 or 8 with this MolCp3 version installed your sending master computer should have MolCp3 version and build number not older than 3 3 521 installed MolCp3 versions installed on your other slave computers running Mac OS X up to 10 6 Snow Leopard Windows 2000 XP or Vista may not be upgraded unless it is specifically required If MolCp3 is installed on your other slave computers running Mac OS X 10 7 Lion 10
9. ED It will blink but with light red when any incoming MIDI event is being accepted by IN Network port source filter However MIDI monitor can reflect incoming MIDI events even for disabled and not opened IN Network ports In this case appropriate LED will show activity staying grey e It is useful in configuring the driver Configuring the driver you can figure that MIDI monitor IN Network port LEDs blinks but there s no input events from appropriate MIDI input in a MIDI sequencer In most cases it means that incoming events are being filtered and dropped because of IN Network port settings In this case appropriate input LED will show activity as d but with white cross sign above f n MIDI monitor doesn t reflect and show MIDI activity in Local pipe port mode On PC when system is loaded MIDI monitor will appear as icon in the System Notification Area System Tray To get monitor s window visible just double click on the icon MIDI monitor window will appear on the screen as top most window None of other windows can override MIDI monitor window except for the context menus If MIDI monitor window hinders you can just close it by clicking X however MIDI monitor will not be unloaded but stay in memory To completely unload terminate MIDI monitor point to monitor s System Tray icon press right mouse button and choose Exit context menu item i On Mac MIDI monitor is not loaded at startup but will be invoked automatically by
10. Using MolCp3 you can easily 1 synchronize sequencers on several computers 2 play music using your sound devices located on different computers i e run GigaStudio on dedicated computer and connect it to your sequencer without annoying necessity of using traditional MIDI interfaces 3 play jam sessions on several computers 4 record music playing from remote computers In any cases listed above you could setup your studio connections without traditional MIDI cables wherever possible Why do you need MolCp3 You need it because MolCp3 is all in one solution for communication between MIDI applications and computers via LAN with multi client device access to their own MIDI devices 1 MoICp3 uses non routable low level Ethernet Il frame based protocol So it will work within LAN only Internetworking is NOT SUPPORTED History MiDloverLAN CP driver version 3 3 build 920 Support for Mac OS X 10 10 Yosemite Mac 128 port mode Golden Edition is added Tooltips in Monitor window MiDloverLAN CP driver version 3 3 build 919 Kernel driver signing and installation fix for Mac OS X 10 9 Mavericks Mac MiDloverLAN CP driver version 3 3 build 918 Fix for detection of network interfaces for Mac OS X 10 9 Mavericks Mac MIDIoverLAN CP driver version 3 3 build 917 Support for Mac OS X 10 9 Mavericks Mac Improvements for communication and browsing Mac PC MIDIoverLAN CP driver version 3 3 build 916 Support for Win
11. after initial installation During this period MolCp3 is fully functional and allows to try it on TWO HOSTS ONLY mac mac mac pc pc pc Initially MolCp3 until registered has built in trial license GEZ At any time during trial period you may turn MolCp3 to PE or GE mode registering MolCp3 with PE2 GE2 license You can find both demo pe license and demo ge license files containing trial PE2 and GE2 licenses in MolCp3 home folder upon completion installation process MolCp3 home folder is at lt WinSysVol gt Program files MusicLabWMolCp III by default Applications MusicLab MolCp3 MolCp3 license protection MolCp3 trial and later registered copy WILL NOTIFY AND IMMEDIATELY STOP TO WORK if more than 2 SE2 PE2 GE2 trial copies if registered more than max number that certain license permits on active hosts connected to the same network are detected To get MolCp3 working after License violation detected you should deactivate extra MolCp3 trial copy either shutdown extra host or uninstall its MolCp3 driver and make system restart on all two in this case other MolCp3 hosts affected by extra MolCp3 trial copy activation Registering and upgrading MolCp3 Having purchased MolCp3 you should register software on each host with license key file attached to purchase confirmation email see also Product Registration Later you could upgrade MolCp3 configuration additionally purchasing any kind
12. ct This identifies text that is relevant with respect to Platinum Edition of the product This identifies text that is relevant with respect to Golden Edition of the product This identifies text that is relevant with respect to PC MS Windows 2k XP Vista 7 8 users This identifies text that is relevant with respect to MS Windows 7 only users This identifies text that is relevant with respect to MS Windows 8 only users This identifies text that is relevant with respect to Apple Mac OSX 10 5 users This indicates additional information This indicates either warning text or additional important information Introduction This document describes MusicLab MolCp Ill Driver MolCp3 which allows to perform MIDI communications between several computers over Local Area Network LAN The driver provides a set of MIDI devices decorated as MolCp3Port 1 16 SE 11 88 PE octal numbering and 111 288 GE octal numbering A pair of MIDI devices appropriate IN and OUT Network ports can be independently configured as Local pipe MolCp3Pipe N MolCp3 presents new generation of previous MIDloverLAN MIDIoverLAN CP products MolCp3 is implemented as native MS DirectMusic WDM driver 1 MolCp3 is implemented as CoreMIDI ver 1 3 MIDI driver MolCp3 provides Network Ports allowing to use several computers connected together via LAN In other words it can receive transmit MIDI events from to remote computers via LAN
13. default by MolCp3 x MIDI driver component as soon as some Network port becomes opened MIDI monitor window will appear on the screen as top most window None of other windows can override MIDI monitor window except for the context menus If MIDI monitor window hinders you can just close it clicking X however MIDI monitor will not be unloaded but just hides To completely unload terminate MIDI monitor manually point to monitor s Dash Board icon press right mouse button and choose Quit context menu item You can also invoke MIDI monitor manually any time you like Applications MusicLab MolCp3 MolCpS3Monitor It will show MolCp3 network activity even if none of Network ports is currently active You can even terminate it when MolCp3 MIDI driver is active That will not affect MolCp3 functionality It is highly recommended to invoke open MIDI monitor window while configuring MolCp3 using Configuration Panel MIDI monitor will dynamically reflect Network ports state and activity NN Applying new settings Since you have finished configuring MolCp3 driver you should apply changes by clicking Apply button If the button stays greyed inaccessible it means that you didn t change either at all or finally settings Once you ve clicked the Apply button system Arrow cursor becomes HourGlass for several seconds and the button Apply becomes greyed again During this time MolCp3 MIDI driver is being reloaded t
14. dows 8 PC MIDIoverLAN CP driver version 3 3 build 915 Fixes for auto positioning and size of GUI controls PC MIDIoverLAN CP driver version 3 3 build 914 The driver initialization procedure is improved Mac Logging is improved Mac PC MIDIoverLAN CP driver version 3 3 build 913 Fix for installation procedure related to signatures of kernel drivers PC Signing of installation package is fixed Mac Remove Target computer list cache feature is fixed Mac MIDIoverLAN CP driver version 3 3 build 912 MIDI events delivery improvement 64 bit arch PC Support for Mac OS X Lion Mountain Lion Mac MIDIoverLAN CP driver version 3 3 build 901 MIDI monitor consumes 50 CPU bug fixed PC MIDIoverLAN CP driver version 3 3 build 900 MIDI monitor doesn t remember LED group selection after computer restart bug fixed PC Buffer overflow bug in MIDI driver component fixed PC MIDloverLAN CP driver version 3 3 build 800 Broadcast mode support for Windows 7 based computers Connectivity improved Uninstall script fixed Mac MIDIoverLAN CP driver version 3 3 build 635 Kernel panic issue in case of MIDI stream width burst particularly in case of MTC MMC fixed Mac Preallocated send buffers pool size customization Mac MIDIoverLAN CP driver version 3 3 build 535 Hung notes when more than one note off event at same time bug fixed PC System requirements i MINIMUM n MS Windows 2000 SP4 256 MB R
15. e you should restart computer upon completion registration otherwise MolCp3 will work incorrectly ER Troubleshooting Installation problems y While you invoke setup executable not having uninstalled previous version before Installation Wizard HESS will suggest you uninstall currect installation first After uninstallation is completed please invoke setup executable once again see also Installation MolCp3Installer package won t be able to install MolCp3 if any version of the product is currently A installed You should uninstall currently installed MolCp3 first see also Uninstallation molcp3 log and attach it to newly created email Fill email subject with MolCp3 installation problem I If Installation Wizard was not completed successfully please open lt WindowsDirectory gt pick up then send your report to supportbox musiclab com We ll try to help you to solve installation problems Visibility of MolCp3 ports q If you use Digital Performer 4 5 you cannot access driver ports within DP while Show connectors Ka option is enabled and nothing really connected to its connectors in Audio MIDI Setup AMS configuration Just disable the option and DP will allow to access MolCp3 ports Otherwise using AMS you should create some virtual device like external instrument and make connections between MolCp3 and this virtual device connectors Also to be allowed to select certain MolCp port a
16. g Leaving this field empty lets the driver use the default port name MolCp3Port N Ki 9 SE MolCp III Control Panel sl B um L I MIDIoverL amp MN CP MIDI IO ports settings musicL AE Local pipe made MIDI part display name Mol oo v MIDI IM Source computer name Source MalCp3Part i IY MIDI OUT Target computer name Target MolCp3Part Send immediately Test MIDI Ch 1 E Send Quantization Time ms 0 2 Iv Enable Log Load Save Apply eS on MolCp Ill Control Panel Eech ann KE me deel 1 M MIDI IN Local pipe loopback mode About Port 2 Port 3 KE SERE EE Port 4 Port display name i Port 5 Source computer name Part 6 Port 7 j Source Port Lt Port 8 pencu dus i MIDI OUT ii d Port display name Port 12 Target computer name v Port 13 E a DE Port 14 Target Port Le E m ate Port 15 Send Immediately Test MIDI Ch 1 Port 16 Settings Realtime Options Wl Show Connectors Send Quantization Time ms 0 2 M Launch Monitor peces v Enable Logging l EEEN EA AA EEEE Use Wireless Load Save 3 Apply 10 IN Network port configuration if enabled If check boxes of the MIDI IN rectangle are both disabled unchecked IN Network Port will receive MIDI events from ANY MolCp3 computers with ANY computer name and from ANY OUT Network port numbers In this case so cal
17. ge Sets number of short buffers for sending MIDI 128 2048 default 256 events up to about 170 bytes B B Sets number of long buffers for sending MIDI l events up to about 1480 bytes Dites EE By default MolCp3 will preallocate 256 short and 128 long buffers When default number of buffers is not enough you can increase number of buffers specifying desired value This may be accomplished in several following steps example 1 open Terminal and print current boot args variable content with the following command nvram boot args lt Enter gt boot args v arch x86 64 2 update boot args variable with new content sudo nvram boot args v arch x86 64 molcp3 int bufs 500 Enter 3 restart your Mac computer Since molcp3 int buffers 500 is added to boot args MolCp3 will allocate 500 short buffers _17 Using wireless network adapters If you tried to use wireless network adapters particularly AirPort and set enabled appropriate option it may cause system crash as soon as you invoke MolCp3CtrlPanel If it is your case you cannot use AirPort adapters and option Use Wireless will be automatically disabled after the system restart 29 Wake up capabilities 4 Primarily Mac computers stop to respond on network events while they enter stand by mode This is v usually a cause when certain computer cannot be shown included in drop down list of source target MolCp3 com
18. l the MIDI events are for the same remote computer Send Quantization Time parameter is common and affects all OUT Network port send timing However in some cases it is necessary to send MIDI event s immediately MIDI synchronization for example So you can enable Send immediately OUT Network port option for a certain port to bypass Send Quantization mechanism and send MIDI events as soon as possible 12 Using MIDI monitor MolCp3 provides MIDI monitor component which communicates with low level network driver component and visualizes state of Network ports and MIDI events activity at a network level jas T The upper row of LEDs presents IN Network ports by number in ascending order left to right whereas the lower row OUT Network ports in the same order Using buttons on the left you can easily show hide certain octet of IN OUT LEDs and thus ganr DD Don optimize monitor window size Port 8 Out er Kai Optionally PE GE monitor window pictures are not shown here Light grey LEDs a reflect Network ports r which are currently disabled inaccessible M 3 D 4 whereas dark grey b enabled ones P Whenever some Network port is being opened 8 c in out d in out e f appropriate LED becomes dark red green c At a time when a MIDI event is being transferred through OUT Network port the appropriate LED will blink with light green d The same refers to IN Network port L
19. led IN Network port filter is completely inactive If check box Source computer name is enabled checked using combo box on the right you can select one of MolCp3 computer names you wish to accept MIDI events from You can also either leave combo box empty or remove any content If combo box Source computer name stays empty MIDI events are accepted from ANY computers regardless of its check box state You can also fill out combo box with any name manually However note if you manually fill out combo box with incorrect unknown or non existent computer name and check box Source computer name gt is enabled checked NONE of incoming MIDI events will be accepted Oo Note MolCp3 computer names are case sensitive If check box Source Port is enabled checked IN Network port filter will additionally filter incoming MIDI events by source port number For example if Source port is set to 2 ONLY MIDI events with source port 2 will be accepted i By default lt Source Port gt number equals IN Network port number You can use any variations of the settings described above OUT Network port configuration if enabled In the Target computer name combo box you can select one of MolCp3 computer names you wish to send MIDI events to _ You can also either leave combo box empty or remove any content If combo box Target computer G name gt stays empty OUT Network port will send MIDI events in broadcast
20. nction issues Boot variables Using wireless network adapters Wake up capabilities MolCp3 and Firewalls Conventions This document uses the following abbreviations and notational conventions MolCp3 Network port Local pipe SE SEn PE PEn GE GEn This identifies MusicLab MolCp III MIDI Driver Version 3 general product s name This identifies dedicated in out MIDI device provided by MolCp3 transfers any kind of MIDI messages via all 16 MIDI channels over local network Dedicated out gt in virtual MIDI wire provided by MolCp3 transfers any kind of MIDI messages via all 16 MIDI channels between several independent applications on standalone computer This identifies Standard Edition of the product up to 16 network ports This identifies Standard Edition license for maximum n computers with MolCp3 installed This identifies Platinum Edition of the product up to 64 network ports octal port numbering This identifies Platinum Edition license for maximum n computers with MolCp3 installed This identifies Golden Edition of the product up to 128 network ports octal port numbering This identifies Golden Edition license for maximum n computers with MolCp3 installed lt WindowsDirectory gt This identifies Windows Directory usually C Windows lt WinSysVol gt This identifies Windows System Volume usually C This identifies text that is relevant with respect to Standard Edition of the produ
21. ndard Edition MolCp3Port 111 118 MolCp3Port 11 18 MolCp3Port 1 8 MolCp3Port 121 128 MolCp3Port 21 28 MolCp3Port 9 16 MolCp3Port 131 188 MolCp3Port 31 88 not available MolCp3Port 211 288 not available not available Driver s Configuration Panel To start configuring MolCp3 invoke Start gt Programs MusicLab gt MolCp III Driver gt Configuration Panel l Applications MusicLab MolCp3 MolCp3CtrlPanel n Prior to begin configuring several MolCp3 computers you should invoke all their configuration panels to browse network for MolCp3 computers The following figures see below show MolCp3 SE configuration panel pictures for different platforms As you can see on figures below various implementations of MolCp3 Configuration Panel differ slightly Optionally PE configuration panel pictures are not shown here To Enable Disable driver ports just check uncheck MIDI IN and or MIDI OUT check boxes Note both IN and OUT driver ports can be enabled disabled independently To switch any Network port to Local pipe mode check the Local pipe box So the Port OUT device will be disconnected from network and connected directly to its IN device In this mode both IN and OUT are always enabled You can also customize Network port display name Fields Port display name are intended for this purpose So you could assign any name you like for the port you re currently configurin
22. o accept the changes Basically in MS Windows any MIDI miniport driver once being installed becomes a part of OS core later every time you turn computer on it reads its settings and starts along with OS long before anyone could logon So the only way to apply changes without restarting computer is to dynamically restart the driver Fortunately MS Windows 2k XP allows doing that Once you ve clicked the Apply button all changes are saved in MolCp3 preferences file MolCp3 MIDI driver applies them as soon as it will be accessed by CoreMIDI Server system component the next time Basically in Mac OSX any CoreMIDI driver is loaded on demand However the only MolCp3 parameter Send Quantization Time is immediately applied as soon as changed regardless of MIDI driver component current state This parameter directly controls MolCp3 low level network component which stays loaded all the time your computer is on So note if you have changed Send Quantization Time and then abandoned to apply this parameter stays changed until either computer is restarted or you change it manually once again Once again note that configuring MolCp3 is not recommended while at least one MIDI application is active otherwise you won t be able to apply changes because of MolCp3 DirectMusic MIDI driver component stays locked and cannot be dynamically reloaded Clicking Apply button you will immediately get Restart required system notification Even if
23. puters while configuring ports on another computer also refer to Configuring the driver In this case you should either wake up source target computer or turn stand by mode off or set its ethernet adapters wake up capabilities MolCp3 and Firewalls m MolCp3 uses sufficiently low level network protocol to be beyond the scope of Windows Firewall MS P Windows XP SP2 Vista Windows 7 or 8 interests In other words Windows Firewall doesn t affect MolCp3 network functionality 0 Note there may be other Firewall specific software which will affect MolCp3 network functionality Contacting MusicLab Web site http www musiclab com Technical support mailto supportbox musiclab com Copyright 2000 2014 MusicLab Inc 07 12 2014
24. rticle first MolCp3 Network port addressing MolCp3 transfers MIDI events from OUT Network port of source computer to IN Network port of target computer Basically target IN Network port can be addressed by both Network port number and computer name An IN Network port has a source filter allowing accepting of MIDI events from certain source computer and or certain source another OUT Network port i MolCp3 provides computer names for addressing purposes which don t differ from regular computer names in most cases for example my g4 Jones xp etc However MolCp3 can find 2 and more remote network interfaces installed into the same computer For example if computer with Jones xp name has two ethernet cards installed built in and additionally installed and MolCp3 copy of my g4 computer can find both it will generate extended computer names Thus computer names for Jones xp interfaces being potential sources targets will be extended with MAC address enclosed in brackets to allow MolCp3 user at my g4 distinguish them In this case computer names will look like Jones xp XXXXXXXXXXXX and Jones xp YYYYY YYY YY YY Port number mapping between different driver modes MolCp3 Platinum Golden Edition modes use special port numbering in octal manner whereas Standard Edition uses serial decimal one based numbering The following table shows port numbering mapping Golden Edition Platinum Edition Sta
25. s MIDI track input you should enable multi record mode using menu item Studio gt Multi Record Malfunction issues If you experience some problems using MolCp3 notice that MolCp3 works incorrectly or some components don t work please create report email with subject like MolCp3 driver malfunction and attach the following files lt WindowsDirectory gt molcp3 log o Library Logs molcp3 log 2 10 5 Leopard 10 8 Mountain Lion 10 9 Mavericks and 10 10 Yosemite var log system log 10 6 Snow Leopard 10 7 Lion var log kernel log Note to locate system log or kernel log don t try to use Finder s Find action It won t look through system folders such as var Instead use Go gt Go to Folder Finder s menu item Then describe the details of your issue and send to supportbox musiclab com Note if you ve got Blue Screen of Death PC or Black Screen of Death Mac please additionally attach to the report email the following file 16 my lt WindowsDirectory gt Minidump Minic lt MMDDYY gt XX dmp n where MMDDY Y current date XX serial number of dump file within current date Anyway you need to pick up the latest by date time dmp file k 4 10 5 10 6 Library Logs PanicReporter Y Y Y Y MM DD XXXXXX panic 10 7 10 10 Library Logs DiagnosticReports Boot variables r Due to Darwin network design specifics MolCp3 network portion of kernel driver needs
26. you later unload all active MIDI applications you will have to restart system anyway MolCp3 CoreMIDI driver component will be able to accept changes being loaded the next time Thus by clicking Apply button you will change settings in MolCp3 driver preferences ONLY Load Save configuration Using lt Load gt lt Save gt buttons you can either restore from or backup to file MolCp3 configuration Target computer list cache To improve MolCp3 to MolCp3 connectivity and avoid often white crosses issue occurance MolCp3 driver caches target computer name list every time Configuration Control Panel application is invoked As soon as you update HW and or rename your computers target computer name list will grow and eventually it may contain computer names that no longer exist At some moment target computer name list will have to be refreshed To accomplish that you need to remove target computer name list cache To perform cache removal silmpy do the following Ka Press and hold lt Ctrl gt key and click on MusicLab Logo on the right top corner of CtriPanel window Press and hold lt Cmd gt key and click About button and then follow onscreen instructions 14 Product registration Using About button you can register product and thus remove trial time limitation If you register SE MolCp3 copy with PE or GE license file demo pe license or demo ge license correspondingly to turn MolCp3 into PE GE mod
Download Pdf Manuals
Related Search
Related Contents
Ortery PeerCall 100 User`s Manual KitchenAid 8284908 Cooktop User Manual General Ledger System Administration Manual Altec Lansing inMotion SLIM for iPod nano Libr 1461_C19.qxd Frigidaire FFFW5100PW washing machine Compex - Maison du Fitness POLYPRESSE - Castilla y Campos AOC E1670SWU LED display JVC 0510KMMCREBET CD Player User Manual Copyright © All rights reserved.
Failed to retrieve file