1. 8002 5 Display Mode 6 Clock 7 Setup Code 8 About 9 Default Press Input 8002 Press 4 to enter unlock Input 4 digits number then input Setup Code or code item then press to update Admin Code 88888888 or 66666666 by default 10 User Card Management This section explains how to configure the key fob function on DMR18 The key fob is used to open the lock Total 1000 key fobs can be registered with one door station When swiping the fob to the door station the distance must be less than 3 centimeter Key Fobs must be registered on the Door station that can be used to open the door Register the Key Fobs All the registered key fobs are called User Cards User Key Fobs New fobs cards need to be registered one by one to the Door station to become a valid User Card User Key Fob and every User Card User Key Fob is related to a certain Monitor Address Flat code When the door station is standby press gt 9008 gt Password 66666666 by default to get into the Debug Mode Menu then Press 1 gt 3 Card Manage gt 1 Add Card to get into the Add Card page Please see the followings 1 AddCard i Please Input Room Code Back Save Enter Add Card menu and Room Code is asked Delete user cards 1 AddCard 01 Show the card Input Room Code 1 AddCard 01 Card n
2. ID Code 2 5 Door Lock Connections 1 Internal Power Supply Mode Use the power of the system to supply for the electronic lock so that the lock can be connected to the door station directly without an additional power supply for the electronic lock Note that the door station can only output 12Vdc power therefore the kind of lock is limited The rated power of the lock must be less than 12Vdc 300mA when using internal power supply mode The GND must connect to the negative of the lock and the COM connect to the positive e Jumper set to 1 2 position for Power off to Unlock safety type Normally closed mode set to 2 3 position for Power on to Unlock type Normally open mode If different unlocking time is needed to be configured change the Unlock Timing on door station In debug state press 1 gt 1 Installer Setup gt 2 Unlock Timing A Connection for Power on to Unlock type set to Normally open on the Unlock Relay mode 12V 300mA EB Jumper set to 2 3 position Em JP_LK B Connection for Power off to Unlock type set to Normally Closed on the Unlock Relay mode 12V 300mA On Jumper set to 1 2 position mm JP_LK 2 External Power Supply Mode When the electronic lock is over 12 Vdc additional power supply for the lock is needed The power supply for the lock must be less than 48Vdc 1 5A e The Jumper mu
3. CDV DDP Door Station User Manual Read this manual carefully before using the product and keep it well for future use Contents 1 Parts and PUNCHONS iicsiapscnnciantaccnoraiteetaniines 1 2 Terminal Descriptions siwuiecsvcwiviuseoraarwunwes 1 3 Door Station MOUNtING civanioswinaniensddanduwaaes 2 4 System Connection sssssessssrrsrrerresrerrrsrrns 3 5 Door Lock Connections ss ssssssssssssrrresrrrrrens 6 6 Door Station Configurations ccceeeeeaees 8 7 Specification ise tied soneiestamieadesiessieematetuons 21 1 Parts and Functions Du T P Camera Lens e r i A a _ lel S Night View LED e j e e Adjustable Camera N A Speaker e m Hiii H r gii LCD Screen e E 7 wo oO ID Card Window e A Eer e Connectiong Port a eE Ba Gers LL Digital Keypad e SH Ze Sa 4 Microphone e E _ i i S WN 5 128 mm JSS With rainy cover 2 Terminal Descriptions i ay ted i SD Card Slot L1 L2 CN LK booooo oo BaASfyY A TIR TIR Bus wwz y 321 oooo0o0o0000 evr Loo lo WSS eee EI e 12V 12VDC power out
4. ch its code is from 16 31 please refer to table 2 1 work ing mode 5 About Default Set The Default Set is very important When the door station miss up the settings in anyway the most quickly and easy way to solve the problem is to activate the default setting on door sta tion The default settings already have all the right settings for one building system that means the system will work normally without any additional settings I 3s 4 lt ID Code t Unlock Timing 05 Unlock Output 0 Card Memory 0 Doorplate Mode Audio Options Parameters Installer Code O Redial Installer Setup Installer Setup Setup PresNO 4 Online Monitors to select to select Online Devices Voltage Measure Back 2 OYIAURWNHE Back In Debug State press 1 In Tools menu press 1 Press 9 key a pass key key word will be asked 9 Default Please Input Password Back Save Input Installer code 66666666 by default then press to save 6 Change Ring Tone There are 12 different ringtones If door station runs as Debug State you can press 1 gt 2 Setup gt 2 Tone Select to enter tone setting page If it runs as Normal State follow these steps 1 Language 1 2 Tone Select 03 Tone Volume 03 Unlock Code 1111 eou 1 Display Mode amp Setup Code 01 12 About Default 3 4 5 6 Clock F 8 E Pr
5. d monitors 05 Online Back 13 Namelist function The door station is designed to have digital keypad and big TFT screen Its namelist was shown on the screen and customer can do the calling operation through the digital keypad guided by Namelist on the screen 2 types of namelist can be shown on the screen DT Config namelist and Simulate namelist Enter namelist page Press 9 in standby mode to display the user namelist Press key to scroll next last page and use key 1 to 8 key on each page to call the flat you want Please refer to the DT Config software user instructions for configure the namelist Send namelist to monitors The namelist can be sent to monitors by door station directly Connect the door station and mon tiors correctly to the system Then press 8012 in standby mode and input password 66666666 by default to send namelist to all the monitors 7 Specification e Power supply e Camera Lens e Power consumption e Screen e Resolution e Video signal e Wiring DC24V Powered by DPS 1 4 ACS 4T image sensor with DSP processor Standby 3W Working status 9W 3 5 inch TFT 320 R G B X240 pixels CCIR EIA Optional 2 wires non polarit The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved Model CDV DDP
6. ess Input 8002 then Press 2 to enter tone Input 2 digits number input Setup Code or Admin select item then press to save Code 88888888 or 66666666 by the setting default 7 Change Installer Code administrator password The Installer Code is the password to access the door station debug State The default Installer Code is 66666666 Note that if the Default Set have been activated the Installer Code will be set to default value ID Code 1 Unlock Timing 05 Unlock Output 0 Card Memory 0 Doorplate Mode Audio Options Parameters lt Tastaller Code Default Redial Installer Setup Setup Fer Card Memory Online Monitors 2 Online Devices Voltage Measure WODINDKHAWNE In Debug State press 1 press 1 press 8 4 key E Save Input a new Installer Code and then press key to confirm 8 How to use code unlock function Please refer to the following operations i EDO When the Door Station isin Input 4 digits Unlock Code If verified correctly standby Press directly door open 15 Jo 9 Change Unlock Code If door station runs as Debug State you can press 1 to activate Tools Menu then select 2 to enter setup page then select 4 item If it runs as Normal State follow these steps 1 Language 2 Tone Select 03 4 Unlock Code 1111 3 Tone Volume 03 Setup
7. for UI Restore all Setup parameters to factory default setting Please Default a note that this operation is an irreversible Table 4 Card Manage set Add Card To add the user card Delete By Card To delete card by user card Delete By M code To delete card by room code Cards Information To show the informations about cards Format To format informations about cards 4 Calling and Unlock Operation The door station is a digital station with 320 240 pixels LCD screen color CCD camera night view LED and digital keypad Visitors can call the apartment by dialing the Flat Code apartment number on the keypad If they don t know the Flat Code apartment number they can search the name list on the screen If the door station is in standby visitors need to press 9 to display the user name list Press key to scroll next last page and use key 1 to 8 key on each page to call the desired flat Residents can open the door by using their unique Unlock Code four digit PIN code If the door station is in standby mode press key then input the four digit unlock to open the door Please refer to part 5 section 7 How to use code unlock function for more detail information Note If the door station works as apartment system mode input 01 32 to call the relevant mon itor If the door station works as villa mode input 01 to call the monitors which its code is from 00 15 Input 02 to call the monitors whi
8. ge from 6s to 600s Wait Timing To show the calling wait time Range from 10s to 600s 30s Talk Timing a the limitation time of talking Range from 10s 90s To enable Indoor Monitor under monitoring state can Monitor amp Speak speak to Door Station at same time If set to 1 talk enabled set to 0 disabled To enable Monitors under monitoring state can open the door at the same time f set to 0 unlock function Monitor amp Unlock is disabled Set to 1 unlock is enable Set to 2 unlock is enable and close at once Set to 3 unlock is enable and close in 5s To show ring times when door station calls monitor 4 Ring Numbers options for choice If set to 0 ring once If set to 1 ring 1 twice If set to 2 ring three times If set to 3 cycle ring To show the namelist display mode If set to 0 it s the DT Config display mode If set to 1 it s the Simulate 0 display mode To show the working mode If set to 0 it s the apartment KORG Mace system mode If set to 1 it s the villa mode Note this section is set on DT Config software for more detail informations please refer to the DT Config software user instructions NameList Display Mode api ae Table 3 Setup Item Language Tone Select Tone Volume Unlock Code Display Mode Clock Setup Code About set To change language the code format is 4 digits Please refer to part 5 section 10 change door station language for more i detail informati
9. il table 2 gt ID Code in details Basic Star Wiring ID Code 0 LIJ ON oonagp 12345 Code 31 DIP 6 on ON BuRagH 23456 Li Code 29 DIP 6 on L Code 3 DIP 6 on Code 1 DIP 6 on Impedance orr ony switch mm N sue g Ha Ele Ho 3 H Hay a ECIN DIP on off off LI L Li LI Li Li 1 1 1 1 1 Impedance fF_9 switch Lam Q Hlo a 3 DIP on off off DBC4 EH lt q 85 260AC la 4 Multi Door Stations Wiring Impedance OFF ON switch _ ABCD DIP on off off 85 260vac T ID Code 1 Ege ID Code 3 ID Code 0 E B ECs mao uge
10. ine door stations and monitors 8107 Portuguese 8108 S Chinese 8109 T Chinese 8110 Greek 8111 Turkish 8112 Polish 8113 Russian 8114 Slovakia 8115 Hungary 8116 Czech Input 4 digits code number Refer to the table are i Download P VINEA TECUH When the door station output a long sound DI that means UI updating is finished Online Search is a very useful function that can help the installer to easily check the connec tivity of all the Monitors Please note Online does not mean via the internet Please refer to the followings Check online door stations Redial Tools Exits Installer Setup 2 Setup Card Memory Online Monitors Online Devices Voltage Measure 5 Online Devices DS1 Online DS2 Fail DS3 Fail DS4 Fail In Debug State press 1 key Press 5 key Check door stations connection status 3198 20 Check online monitors 4 Online Monitors Redial Installer Setup Pee cup sijele lt Tools Card Memory Online Monitors Exits Online Devices Search Range Voltage Measure Back Save In Debug State press 1 Press 4 key Input 2 digits key monitor code 4 4 Online Monitors Search Range input the monitor address For example RAE input the range from 01 to 05 You will see the connection ne S status of the selecte
11. me that how long the door keeps open 05 when door is released Range from 01 to 99 seconds 5 seconds To set the unlock mode to match the corresponding lock Range from 0 to 1 oll 0 Power on to Unlock Mode Normally Open Mode 1 Power off to Unlock Mode Normally Closed Mode To set the card location If set to 0 the card is saved in Card Manage 0 door station If set to 1 the card is saved in DT IPC To set the calling mode If set to 0 it s the auto mode that means the calling will be activated directly 0 Doorplate Mode after inputting 2 digits code If set to 1 it s the manual Auto mode mode that means you should press button to acti vate the calling after inputting the code To set talking mode when cutting voice or mixed voice appears set to 1 DS IM talking set the voice matching between Door Station and Indoor Monitor DS NT talking set the voice matching between Door Station and Guard Unit Parameters To show the parameters please refer to table 2 1 Installer Code To change door station administrator code 66666666 Audio Options Note this operation is irreversible Once restore is Default activated all parameters will return to factory default setting except the information of access card O Table 2 1 Parameters set Monitor Timing To show the monitor time Range from 6s to 600s 30s Switch Timin To show the surveillance time for each Door Station or 40s 9 CCTV camera Ran
12. ons Select the chime of Door Station in calling wait state 12 03 chord tunes are available key in 01 to 12 to select Adjust the tone volume for door station in calling Range from 08 01 15 To change unlock code in Common Code Unlock mode in 11111 4 digits format 1111 is the default unlock code To select the Door Station screen menu If set to 0 the screen displays the visitor s image when talking If set to 1 the 0 screen displays icons when talking To set date and time Date formattif set to 0 date format is DD MM YY if set to 1 date format is MM DD YY Time format if set to 0 time format is 24 hour standard If set to 1 time format is 12 hour standard To change the Program Code 88888888 1 Hardware version To show the Door Station including ACS hardware information 2 Software version To show the Door Station including ACS software information 3 Manufacture Date To show the manufacturing date 4 Dialing Counts To show the call operation counts 5 Calls Counts To show the established calling counts 6 Unlock Counts To show the unlock operation counts 7 Standby Voltage To show the voltage that the door sta tion in standby 8 Working Voltage To show the voltage that the door sta tion in working 9 Video Standard PAL or NTSC standard 10 UI_CODE To show the UI byte counts and check box 11 MCM VER To show the version and language for MCM 12 Updated To show the updated time
13. ord will be asked input 8 digits installer password 66666666 by default then press key to save format operation is activated all card information will be cleared 11 Change Door Station Language It s convenient to change the user interface for CDV DDP Just put the config files to the SD card 4 Cards Information Card Count 1000 Back Save 5 Format Please Input Password and by means of the digital keypad of door station only 30 seconds is needed to update Step 1 Insert the SD card which is con tained config files into the SD card slot where is at the back of the door station Refer to the right diagram Step 2 If door station runs as Debug State you can press 1 to activate Tools Menu select 2 to L1 L2 SD Card Slot pe on oooo00000 enter setup page then select 1 item If it runs as Normal State follow these steps Press Input 8002 then Tone Select 03 Tone Volume 03 Unlock Code 1111 Display Mode Glock Setup Code About Default 1 Language Code Number Back Save Press 1 input Setup Code or Admin Code Language code number 8101 English 8102 French 8103 Spanish 8104 Italian 8105 German 8106 Dutch 12 Search onl
14. put e LK GND Power ground LK COM Common contact of the Relay NO Normally open contact of the Relay refer to DT technical guide for Lock connection detail informations e EB Exit button connection port EB Exit button connection port JP LK For electronic lock safety type setting refer to Door Station Lock Connections T R USB RS485 communication terminal negative e T R USB RS485 communication terminal positive Bus L1 L2 non polarity bus line 3 Door Station Mounting Drill a hole and attach the rainy cover to it The view for rainy cover after mounted Camera angle Adjust the camera angle and attach the metal to the panel and wire correctly Attach screws to fix the Attach the unit to the rainy metal box cover correctlly Attach the baffle to protect the unit from droping The last view for all mounting 4 System Connection Basic IN OUT Wiring JUNG 3456 Code 32 DIP 6 on tole ON malin 123456 Code 31 DIP 6 off tele aa 1 2 3456 Code 1 DIP 6 off 85 260AC tet ID Code 0 Please refer to section 6 gt part 3 About Debug Tools gt Basic Tools E Deta
15. st be removed when using external power supply The default setting is Power on to Unlock type Normally open mode if use Power off to Unlock type change the Unlock Relay mode to Normally closed mode If different unlocking time is needed to be configured change the Unlock Timing on door station In debug state press 1 gt 1 Installer Setup gt 2 Unlock Timing C Connection for Power to Unlock type set to Normally Open on the Unlock Relay mode default Note Cut off this line when using external power supply set to Normally Closed on the Unlock Relay mode a Note Cut off this line when Remove the Jumper using external power supply JP_LK 6 Door Station Configurations 1 About room code address Room Code also called room address is a code assigned to each monitor to identify different monitors each monitor have a unique room code in one building room Code is stored in each Monitor s inner EEPROM memory and does not lose even the monitor is power off 2 About Debug State The Debug State is your starting point for using all the applications on CDV DDP Redial Tools e707 00 8 Exits When Door Station is in input 9008 then input the Debug State menu is launched standby press key Admin Code 66666666 by default Press 2 key to exit ou
16. t the debug state 3 About Debug Tools During working at Debug State press 1 to enter tools page Debug Tools overviews is shown as below Redial Installer Setup Setup Tools Card Memory Online Monitors Exits Online Devices Voltage Measure Table 1 1 Installer Setup 2 Setup 3 Card Manage 4 Online Monitors 5 Online Devices 6 Voltage Measure ID Code 0 Unlock Timing 05 Unlock Output 0 Card Memory 0 Doorplate Mode Audio Options Parameters Installer Code Default OONDARWHD Language 1 Tone Select 03 Tone Volume 08 Unlock Code 1111 Display Mode Clock Setup Code About Default CONMANRWNS Add Card Delete By Card Delete By M code Cards Information Format arwWwnr To search the online monitors input the monitor code number to search To search the online door stations Max 4 door station can be searched To check the voltage of the monitor note that the moni tor must be online Basic Tools Detail Table 2 Installer Setup set If only one door station is installed in this building set to 0 ID Code If multi door stations are installed primary door station hae must be set to 0 and other slave door stations must be set from 1 to 3 Note that max 4 door stations are available in one building Unlock Timing To set the ti
17. umbs 15977131 Show The Card Save Read the card to be authorized Registered User Cards Key Fobs can be deleted from the Door station once doing the delete operation the card key fobs can not open the door anymore They can also be re registered again to become a valid User Card User Key Fob There are two ways to delete User Cards User Key Fobs 1 Delete by card show the unwanted card s when the Door station is in Delete Card Mode 2 Delete by room number delete all the registered User Cards related to that room number Delete By Card In Debug State Press 1 gt 3 Card Manage gt 2 Delete By Card to enter Delete by Card page as shown on the right then show the cards you want to de lete one by one Delete by Room Number In Debug State Press 1 gt 3 Card Manage gt 3 Delete By M Code to enter Delete by M Code page as shown on the right then Input the Room Code press to confirm all associ ated cards will be deleted 2 Delete By Card Show The Card 2 Delete By Card Card numbs 15977131 Show The Card Save 3 Delete By M code Please Input Room Code 3 Delete By M code 01 Updated Je 18 Card information Enter Card Information page and the screen will display the authorized User Cards count and card read access events count Format Enter Card Format page a passw