1. AQ Trol HP TL Twistlock 120 20A linecord receptacle 2 51mm rigid PVC piping or 1 144 38 32mm flexible hose AQ Trol RJ Straight blade 120V 15A linecord receptacle adapters for return jet mounting AQ Trol RJ TL Twist lock 120V 20A linecord receptacle adapters for return jet mounting NOTE Before installing this product as part of a saline water purification system in an above ground pool with an immediately adjacent natural stone patio decking a qualified stone installation specialist should be consulted regarding the appropri ate type installation sealant if any and maintenance of stone used around a saline pool with electronic chlorine generator in your particular location and cir cumstances NOTE The use of dry acid sodium bisulfate to adjust pool pH is discouraged especially in arid regions where pool water is subject to excessive evaporation and is not commonly diluted with fresh water Dry acid can cause a buildup of by products that can damage your chlorinator cell 1 control unit and that the wire is not cut or damaged Make sure you have at least 12 of straight pipe before the flow switch If there is adequate flow and the LED is still on check that the arrows on the flow switch on top of hex are pointing in the direction of flow 6 Test Salt Level LED illuminated or flashing Take a sample of your pool water to your local Authorized Aqua Rite Dealer and have the salt level tested No sal
2. WAY AFTER LEAVING THE FACTORY FOR THE ABOVE IDENTIFIED CHLORI NATION PRODUCTS THESE WARRANTIES ALSO ARE VOID IF DURING THE WARRANTY PERIOD YOU USE A REPLACEMENT CHLORINATOR CELL OTHER THAN AN UNMODIFIED NEW HAY WARD GOLDLINE CHLORINATOR CELL PUR CHASED FROM HAYWARD GOLDLINE IFA WARRANTY BECOMES VOID YOU STILL MAY PURCHASE SERVICE AND OR TELEPHONE TECHNICAL SUPPORT AT THE THEN CURRENT TIME AND MATERIAL RATES Table of Contents The Aqua TP ies ssssisscsccssssconvonsnnantearcarsiasmacnieiassaseemins Water CHEIMISERY isssssscisiscesosisncesndinnsnsntaancususesnsecasonnsacesons CONtrols eeeeee cece cece eccecsnssssesesceececeececcecccceeacaseesesseesesees Maintenance ceeeeescsssscssccssecsscecccccssecesccecccccceeeees Mounting ecin iarsi eiei Plumbing eccere mene e ee iaiia TROUBLESHOOTING TROUBDIESHOOCING waiissiisicscs coscssscssnsansnasnscscensenenaianosnasasnsonss Warran tyeri cast cprtndirnacetorel ornare iE Operation The Aqua Trol is an automatic chlorine generation system with a built in filter pump timer designed specifically for above ground pools The operation requires a low concentration of salt sodium chloride in the pool water at levels low enough that it normally will not be tasted The Aqua Trol automatically sanitizes your pool by converting the salt into free chlorine which kills bacteria and algae in the pool through a process called electrolysis Because chlorine will revert back to sodium
3. and flow switch not used on RJ systems are plumbed in the return line to the pool Install after downstream all the pool equipment filter heater solar etc The kit included in the Aqua Trol provides the necessary plumbing components for either 2 5 1mm rigid PVC piping installation or 1 144 38 32mm flexible hose installation An overview of the Aqua Trol system with the hose pipe installation HP is shown on the previous page see below for detail on the return jet mounting Hose Pipe installations HP option Install the cell and flow switch as shown in the diagrams below Always make sure that the flow switch is downstream from the cell When using the hose adaptors remove the o ring from the pipe union tail piece and install them in the hose tailpieces Tighten all union nuts BY HAND for a watertight seal CR wE P l FROM PUMP e z Hose Assembly FROM PUMP gt _ 10 Poot Pipe Assembly Return Jet installation RJ option Unscrew the the hose adaptor from the pool return jet fitting and in its place screw in the right angle cell mounting adaptor Note that this installation does NOT require a flow switch however it is very important that the cell be mounted vertically directly below the return jet in order to allow the gases produced in the cell to naturally dissipate in the pool Attach the c
4. of water because of splashing backwashing or draining because of rain Salt is not lost due to evaporation Type of Salt to Use It is important to use only sodium chloride NaCl that is 99 pure This is common food quality or water softener salt available in 40 80 Ib bags at your local Hayward Goldline dealer It is also acceptable to use water conditioning salt pellets how ever it will take longer for them to dissolve Do not use rock salt salt with more than 1 yellow prussiate of soda salt with more than 1 of anti caking additives or iodized salt How to Add or Remove Salt Turn the filter pump on and add the salt directly into the pool Brush the salt to speed up the dissolving process to not allow the salt to sit in a pile on the bottom of the pool Run the filter pump for 24 hours with the suction coming from the main drain use the pool vacuum if there is not main drain to allow the salt to evenly disperse throughout the pool The salt display may take 24 hours to respond to the change in salt concentration The only way to lower the salt concentration is to partially drain the pool and refill with fresh water Bonding A lug used for bonding is attached to the bottom of the Aqua Trol enclosure Connect to the pool bonding system using minimum 8AWG copper wire if required by code Pump Output The Aqua Trol s filter pump output is rated at 120 VAC 15 A max Check the electrical rating marked on the pump motor Conne
5. ELECTROLYTIC CHLORINE GENERATOR BASIC POOL MAINTENANCE REQUIREMENTS TEST IDEAL RANGE ADJUSTMENT REQUIRED Raise desired output to gt Free Chlorine 1 0 3 0ppm increase lower desired output to decrease OR increase or W decrease pump filtration time pH 7 2 7 8 Too high add muriatic acid S Too low add soda ash A gt Alkalinity 80 120 ppm Add baking soda to increase F7 Add acid as required to decrease z O Salt 2700 3400 ppm Add salt as required to increase a Stabilizer 60 80 ppm Add cyanuric acid to increase E Calcium 200 400 pom Add calcium to increase 3 Drain and add water to decrease 6 Electrolytic Cell inspect amp clean Refer to section in manual Questions Refer to www goldlinecontrols com for latest manual revisions additional information and helpful service 620 Division St 092016K RevL Elizabeth NJ 07207 Copyright 2010 Hayward Inc Aqua Trol Above Ground Pool Chlorine Generator Operation and Installation Manual AQ TROL RJ AQ TROL RJ TL AQ TROL HP AQ TROL HP TL HAYWARD www haywardnet com IMPORTANT SAFETY INSTRUCTIONS When using this electrical equipment basic safety pre cautions should always be followed including the follow ing READ AND FOLLOW ALL INSTRUCTIONS e Disconnect all AC power during installation Warning To reduce the risk of injury do not permit children to use this product unless the
6. below ppm _ 22 500 30 000 37 500 45000 52 500 60 000 67 500 0 160 213 267 320 373 427 480 73 97 121 145 170 194 218 200 150 200 250 300 350 400 450 69 91 114 136 159 182 205 40 140 187 233 280 327 373 420 AQUA TROL 64 85 106 127 148 170 191 D AQ TROL XX a 130 173 ay 260 303 347 390 ei I 69 79 118 138 158 177 NEUTRAL ae 120 160 20 240 280 320 360 ALLEL ee a 55 73 109 127 145 164 GROUND GFCI BONDING 110 147 7 E 220 257 293 330 SUBPANEL OUTLET Oor w e l aoo a7 133 a50 i200 100 133 n 7 200 233 267 300 46 61 91 106 121 136 o PUMP 1400 120 ie 180 210 240 270 A 55 68 82 95 109 123 1600 80 107 133 160 187 213 240 36 48 1 73 85 97 109 1800 70 93 117 140 163 187 210 32 42 53 64 74 85 95 GectenGuN pen 60 80 100 120 140 160 180 BREAKER 27 36 45 55 64 73 82 TWIST LOCK AQUA TROL 2200 50 67 150 E l PLUGS L520 AQ TROL XX TL 23 30 68 i 1 S4 HO bah 40 53 120 NEUTRAL C a 24 55 LLLE s 40 50 60 70 80 90 FETT ee ae 18 23 27 32 36 41 GROUND oni ieee BONDING 20 27 33 40 47 53 60 SUBPANEL Loo
7. chloride after killing the bacteria these reactions will continuously recycle virtually eliminating the need to add sanitizing chemicals to your pool The only time you may need to add more salt to the pool is when water is replenished due to backwashing draining or splashing not evaporation The Aqua Trol incorporates a built in timer to control the pool filter This timer insures that the proper daily filtration and sanitization occurs The Aqua Trol is designed to handle the purification needs of the average residential above ground swimming pool of up to 18 000 gallons 67 500 liters The actual amount of chlori nation required to properly sanitize a pool varies depending upon bather load rainfall temperature and the pool s cleanliness The Aqua Trolis available with several different options to allow for easy installa tion on a wide variety of above ground pools The cell may be connected with 11 2 1 flexible hose or to 2 rigid PVC pipe when the HP option is ordered or the cell may be mounted directly to the pool return jet when the RJ version is ordered Similarly the electrical connections may be made via 120V 15A straight blade linecord and receptacle standard Aqua Trol version no option designation or may be made via a 120V 20A twist lock linecord and receptacle when the TL version is ordered AQ Trol HP Straight blade 120V 15A linecord receptacle 2 51mm rigid PVC piping or 1 114 38 32mm flexible hose
8. cting a pump with a higher amperage rating may result in permanent damage to the Aqua Trol The 120 VAC standard or twist lock pump receptacle is located outside on the bottom of the enclosure Electrolytic Cell and Flow Switch The cell and flow switch plug into connectors on the Aqua Trol electronics unit Note that return jet units RJ option will NOT have a flow switch See diagram below Phone jack Cutout for to flow switch cell cable oe a C 2 r C co Bottom of AquatTrol Enclosure OUTPUT POWER INPUT POWER 120 VAC linecord 120 VAC receptacle Bonding lug to to pool pump to GFCI receptacle breaker pool bonding system 12 Wiring Power must be shut off at the circuit breaker before performing any wiring Be sure to follow Local and NEC CEC electrical codes The Aqua Trol has been designed to easily wire into typical above ground pool systems To provide safe operation the Aqua Trol must be properly grounded and bonded POUNDS and Kg OF SALT NEEDED FOR 3200 PPM Input Power Models with the standard 120 VAC line cord should be plugged into a GFCI recep SaLe E ela O O water tacle Twist lock models should be plugged into a twist lock receptacle wired to a Current salt GFCI circuit breaker For Canadian installations Connect to a circuit protected by level 6 000 8 000 10 000 12 000 14 000 16 000 18 000 a Class A ground fault interruptor See diagram
9. d of one 1 year These warranties are applicable from the initial date of installation on private residential swimming pools in the US and Canada Hayward Goldline warrants all the above identified pool automation and chlorination prod ucts installed on commercial swimming pools and on swimming pools outside of the US and Canada for a period of one 1 year Likewise Hayward Goldline warrants all accessories and replacement parts for the above identified pool automation and chlorination products for a period of one 1 year Each of these warranties is not transferable and applies only to the original owner Proof of purchase is required for warranty service If written proof of purchase is not provided the manufacturing date code will be the sole determinant of the date of installation of the product To obtain warranty service or repair please contact the place of purchase or the nearest Hayward Goldline authorized warranty service center For more information on authorized service centers please contact the Hayward Goldline Technical Service Support Center 61 Whitecap Road North Kingstown RI 02852 or visit the Goldline web site at www goldlinecontrols com or the Hayward website at www haywardnet com WARRANTY EXCLUSIONS 1 Material supplied or workmanship performed by others in process of installation 2 Damage resulting from improper installation including installation on pools larger than the product rating 3 Problems resu
10. e table on page 2 summarizes the levels that are recommended by the National Spa and Pool Institute NSPI The only special requirement for the Aqua Trol is the salt level and stabilizer It is important to maintain these levels in order to prevent corrosion or scaling and to ensure maximum enjoyment of the pool Test your water periodically Your local pool store can provide you with the chemicals and procedures to adjust the water chemistry Be sure to tell the pool store that you are using an Aqua Trol chlorine generator CHEMICAL IDEAL LEVELS Salt 2700 to 3400 ppm Free Chlorine 1 0 to 3 0 ppm pH 7 2 to 7 6 oie Ci 60 to 80 ppm 80 ppm best Total Alkalinity 80 to 120 ppm Calcium Hardness 200 to 400 ppm Metals 0 ppm Saturation 2 to 2 0 best Index Saturation index The saturation index Si relates to the calcium and alkalinity in the water and is an indicator of the pool water balance Your water is properly balanced if the Si is 0 2 If the Si is below 0 2 the water is corrosive and plaster pool walls will be dissolved into the water If the Si is above 0 2 scaling and staining will occur Use the equation and chart below to determine the saturation index Si pH Ti Ci Ai 12 1 Calcuim Total Ci Jalkalinity A Hardness How to use Measure pool pH temperature calcium hardness and total alkalinity Use the chart above to determine Ti Ci and Ai from y
11. ed the salt level is too high and Aqua Trol has shut down INSPECT CELL A flashing indicator signifies that either the cell efficiency is reduced or that it is time for regularly scheduled cell inspection In either case inspect the cell and clean if necessary Pressing the diagnostic button next to the display for 3 seconds will stop the flashing LED When illuminated steady cell efficiency is greatly reduced and the Aqua Trol has stopped producing chlo rine Inspect clean or replace if necessary Salt Display The Salt Display shows the current salt concentration of the pool water Readings are in ppm parts per million Refer to the Water Chemistry section for recommended salt levels as well as how to add remove salt The factory default display is in English ppm If Metric units grams per liter are preferred push the diagnostic button next to the display once The display will now show the pool water temperature in degrees Fahrenheit With the temperature displayed move the main switch from AUTO to SUPER CHLORINATE to AUTO The temperature display will instantly change to degrees Celsius and the salt display will switch to grams liter Repeat this process to switch back to English units ppm and Fahrenheit Operation By understanding how the Aqua Trol operates you ll be sure to use it more effec tively for maximum convenience and performance Assuming that the water chemical levels are in the recommended range there are t
12. ell to the union and then use the fittings supplied to attach the lower end of the cell to either the hose or rigid PVC pipe coming from the pools filtration system Tighten all union nuts BY HAND for a watertight seal FROM FILTER 10 Installation Installation must be performed in accordance with Local and NEC codes Preparing Pool Water Refer to page 2 for recommended chemical levels The pool s chemistry must be balanced BEFORE activating the Aqua Trol NOTE If the pool does not have new water add 1 quart 1 liter of metal remover and 1 quart 1 liter of non copper based algaecide to the pool per manufacturers instructions This ensures a quick troublefree transfer to the Aqua Trol system Mounting the Aqua Trol Control The Aqua Trol is contained in a raintight enclosure that is suitable for outdoor mounting The control must be mounted a minimum of 5 ft 2 meters horizontal distance or more if local codes require from the pool The control is designed to mount vertically on a flat surface Because the enclosure also acts as a heat sink disperses heat from inside the box it is important not to block the four sides of the control Do not mount the Aqua Trol in a panel or tight enclosed area RETURN SKIMMER FLOW SWITC i BNG PUMP FILTER CELL OHAaYwaRD 120 VAC GFCI OUTLET AQ TROL HP Cont
13. eturn lines before any freezing conditions occur The electronic control is capable of withstanding any winter weather and should not be removed Spring Start up DO NOT turn the Aqua Trol on until the pool water chemistry has been brought to the proper levels This information can be found on page 2 8
14. hlorinates shocks the water for 24 hours filter pump must be on during this time or until the power has been turned off whichever comes first At the end of the super chlorinate time be sure to put the switch back into the AUTO position OFF The OFF position prevents the Aqua Trol from energizing the electrolytic cell In this position there is no chlorine generation NOTE To service any of the pool equipment or the Aqua Trol turn the power off at the circuit breaker Desired Level adjustment knob This setting is used to control the amount of chlorine the Aqua Trol generates Raise this setting to increase chlorine level and lower it to decrease chlorine level Indicator LED s POWER When illuminated the Aqua Trol has input power GENERATING This LED is on steady during normal operation When flash ing the pool water is too hot or cold to operate SUPER CHLORINATE Illuminates during Super Chlorination See description above 6 NO FLOW When illuminated the flow switch has detected no flow and the Aqua Trol has stopped generating chlorine A flashing LED indicates a 15 60 second time delay period TEST SALT LEVEL When flashing the salt level is low below 2700ppm and Aqua Trol is generating at low efficiency When illuminated steady the salt level is too low and Aqua Trol has shut down Before adding large quantities of salt it is advisable to have your salt level professionally checked HIGH SALT When illuminat
15. hree factors that you can control which directly contribute to the amount of chlorine the Aqua Trol will generate 1 filter time each day hours 2 the amount of salt in the pool 3 the Desired Level setting To find the optimum Desired Level setting start at a fairly high setting and work downward It will take a few days of adjustments to find the ideal setting for your pool spa Once determined it should only take minor adjustments if at all to com pensate for differing salt levels due to splashing backwashing rain etc Because the production of chlorine is affected by water temperature it is important to check chlo rine levels during periods of unusually high or low pool water temperatures The Aqua Trol control will not produce chlorine at temperatures below 50 F If your pool will be below this temperature for any length of time you must chlorinate manually NOTE After the ideal Desired Output setting has been found you may need to raise the setting when the pool water temperature increases significantly when there is higher than normal bather load or when your chlorinator cell ages You may need to lower the setting when the pool water temperature decreases significantly or there are long periods of inactivity Maintaining the Aqua Trol System To maintain maximum performance it is recommended that you open and visually inspect the cell every 3 months or after cleaning your filter The Aqua Trol will remind y
16. lt display Common Problems and Solutions 1 Power LED noton Check to make sure 120VAC input power is connected to the Aqua Trol control Verify input voltage with a voltmeter If there is input power the fuse may have blown The Aqua Trol is protected by a 20 amp mini ATO fuse located on the circuit board above the cell connector 2 Filter pump not running Check that the time clock manual switch is in the auto center position or in the on top position If in auto then check that the time is correct check am pm by using the 24 hour indicator located near the 2 o clock position and that the trippers are in the out position 3 Generating LED not on The Aqua Trol only generates chlorine when the filter pump is running the main switch is in the AUTO or SUPER CHLORINATE position and none of the red fault LEDs are illuminated 4 Generating LED flashing The temperature of the pool water is too high or low to operate You can override this by switching the main switch to SUPER CHLORINATE The Aqua Trol will run at maximum output for the remainder of the current pump cycle or 24 hours which ever comes first 5 No Flow LED illuminated The Aqua Trol has sensed a no flow condition and has stopped generating chlo rine Check that the flow switch is plugged into the connector on the bottom of the 13 Water Chemistry As with any pool it is important that you maintain chemical makeup of the pool water Th
17. lting from failure to install operate or maintain the product s in accordance with the recommendations contained in the owners manual s 4 Problems resulting from failure to maintain pool water chemistry in accordance with the recommendations in the owners manual s 5 Problems resulting from tampering accident abuse negligence unauthorized repairs or alternations fire flood lightning freezing external water degradation of natural stone used in or immediately adjacent to a pool or spa war or acts of God DISCLAIMER THE EXPRESS LIMITED WARRANTIES ABOVE CONSTITUTE THE ENTIRE WARRANTIES WITH RESPECT TO THE ABOVE IDENTIFIED HAY WARD GOLDLINE POOL AUTOMATION AND CHLORINATION PRODUCTS AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WAR RANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THESE WARRANTIES GIVE YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS OF EQUIPMENT LOST PROFITS OR REVENUE COSTS OF RENTING REPLACEMENTS AND OTHER ADDITIONAL EXPENSES EVEN IF THE SELLER HAD BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES SOME STATES DO NOT ALLOW THE EXCLUSION OF LIMITATION OF INCI DENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU NO WHOLESALER AGENT DEALER CONTRACTOR OR OTHER PERSON IS AUTHORIZED TO PROVIDE SUPPLEMENT OR MODIFY ANY WARRANTY ON BEHALF OF HAYWARD GOLDLINE THESE WARRANTIES ARE VOID IF THE PRODUCT HAS BEEN ALTERED IN ANY
18. osits off of the plates Note that a buildup on the cell indicates that there is an unusually high calcium level in the pool old pool water is usually the cause If this is not corrected you can expect to have to periodically clean the cell The simplest way to avoid this is to bring the pool chemistry to the recommended levels as specified Mild Acid Washing Use only in severe cases where flushing and scraping will not remove the majority of deposits To acid wash turn off power to Aqua Trol Remove cell from piping In a clean plastic container mix a 4 1 solution of water to muriatic acid one gallon of water to one quart of muriatic acid ALWAYS POUR ACID INTO WATER NEVER POUR WATER INTO ACID Be sure to wear rubber gloves and appropriate eye protection The level of the solution in the container should just reach the top of the cell so that the wire harness com partment is NOT submerged It may be helpful to coil the wiring before immers ing the cell The cell should soak for a few minutes and then rinse with a high pressure garden hose If any deposits are still visible repeat soaking and rinsing Replace cell and inspect again periodically Winterizing The Aqua Trol electrolytic cell and flow detection switch will be damaged by freezing water just as your pool plumbing would In areas of the country which experience severe or extended periods of freezing temperatures be sure to drain all water from the pump filter and supply and r
19. ou to do this by flashing the Inspect Cell LED after approximately 500 hours of operation After you inspect the cell and clean if necessary press the small diagnostic button next to the display for 3 seconds to stop the flashing Inspect Cell LED and start the timer for the next 500 hour inspection period The Aqua Trol electrolytic cell has a self cleaning feature incorporated into the electronic control s logic In most cases this self cleaning action will keep the cell working at optimum efficiency In areas where water is hard high mineral content and in pools where the water chemistry has been allowed to get out of balance the cell may require periodic cleaning The Inspect Cell LED will indicate if cell efficiency is decreased and servicing is necessary If the Inspect Cell LED remains on after a thorough cleaning the cell may be worn and re quire replacement Servicing and Cleaning the Aqua Trol cell Turn off power to the Aqua Trol before removing the electrolytic cell Once removed look inside the cell and inspect for scale formation light colored crusty or flaky deposits on the plates and for any debris which has passed through the filter and caught on the plates Ifno deposits are visible reinstall If deposits are seen use a high pressure garden hose and try to flush the scale off If this is not successful use a plastic or wood tool do not use metal as this will scratch the coating off the plates and scrape dep
20. our measurements Insert values of pH Ti Ci and Ai into the above equation If Si equals 2 or more scaling and staining may occur If Si 2 or less corrosion or irritation may occur CORROSIVE a am SCALING OK Salt Level Use the chart on page 4 to determine how much salt in pounds or Kgs needs to be added to reach the recommended levels Use the equations below measure ments are in feet gallons and meters liters if pool size is unknown Gallons pool size in feet Liters pool size in meters Rectangular Length x Width x Average Depth x 7 5 Length x Width x Average Depth x 1000 Diameter x Diameter x Diameter x Diameter x Roung Average Depth x 5 9 Average Depth x 785 Length x Width x Length x Width x Oval Average Depth x 6 7 Average Depth x 893 The ideal salt level is between 2700 3400 ppm parts per million with 3200 ppm being optimal If the level is low determine the number of gallons in the pool and add salt according to the chart on page 4 A low salt level will reduce the efficiency of the Aqua Trol and result in low chlorine production A high salt level can cause the Aqua Trol to shutdown and may begin to give a salty taste to your pool generally the salt will begin to be tasted at a level of about 3500 4000 ppm The salt in your pool is constantly recycled and the loss of salt throughout the swim ming season should be small This loss is due primarily to the addition
21. p aiid a z as aay en en 10 is iz 20 23 27 30 l z000 6 8 9 11 12 14 PUMP 3200 Ideal Ideal Ideal Ideal Ideal Ideal Ideal 3400 OK OK OK OK OK OK 3600 Dilute Dilute Dilute Dilute Dilute Dilute Dilute 11 4 Stabilizer Cyanuric Acid Always check stabilizer cyanuric acid when checking salt These levels will most likely decline together Use the chart below to determine how much stabilizer must be added to raise the level to 80 ppm POUNDS and Kg OF STABILIZER CYANURIC ACID NEEDED FOR 80 PPM Gallons and Liters of Pool Spa water nt 6 000 8 000 10 000 12 000 14 000 16 000 18 000 Level ppm 22500 30000 37500 45000 52500 60000 67500 4 0 5 3 6 7 8 0 9 4 10 7 12 0 0 ppm 1 8 2 4 3 0 3 6 4 3 4 9 5 4 3 5 47 5 8 7 0 8 2 9 4 10 5 10 ppm 1 6 2 1 2 6 3 2 3 7 4 3 4 8 3 0 4 0 5 0 6 0 7 0 8 0 9 0 20 ppm 1 4 1 8 2 3 2 7 3 2 3 6 2 2 25 3 3 4 2 5 0 5 9 6 7 75 30 ppm 1 1 1 5 1 9 2 3 2 7 3 0 3 4 40 ppm 2 0 27 3 3 4 0 4 7 5 4 6 0 9 1 2 1 5 1 8 2 1 2 4 2 7 15 2 0 25 3 0 3 5 40 45 50 ppm 7 9 1 1 1 4 1 6 1 8 2 0 1 0 1 3 1 7 2 0 2 4 27 3 0 60 ppm 5 6 8 91 1 1 1 2 1 4 0 5 0 7 0 8 1 0 12 1 4 1 5 70 ppm 2 3 4 45 54 64 68 80 ppm 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Plumbing The cell
22. rols Timer The pool filter pump should run long enough to circulate the entire volume of pool water each day This will vary depending on pump size pool plumbing and pool size Consult a local pool store to help determine the appropriate run time for your pool Set the Aqua Trol s timer by rotating the clock hands in a clockwise direction The arrow positioned approximately 2 o clock on dial points to the current time The internal hands show time at a glance On the outside of the timer there are a series of small slide trippers Each tripper controls a 15 minute interval Set the trippers for the desired run time OFF Push trippers IN toward center ON Pull trippers OUT away from center Manual Control There is a switch on the timer located at approximately the 4 o clock position that allows the pump to be manually turned on or off 1 up pump ON center timer controls pump 0 down pump OFF Main Switch AUTO For normal operation the Main Switch should be left in the AUTO position In this position the Aqua Trol will produce chlorine according to the Desired Level adjustment setting for the entire filtering pumping cycle SUPER CHLORINATE When you have an abnormally high bather load a large amount of rain a cloudy water condition or any other condition which needs a large amount of purification to be introduced put the Main Switch in the SUPER CHLORINATE position This electronically super c
23. sive scaling on cell High level of Nitrogen in pool water Yellow Out or similar treatment recently used Some yellow algae treatments will use chlorine at a very high rate and deplete the residual free chlorine Manu ally shock the pool if indicated in the directions on the algae treatment It still may be a matter of days before the pool returns to normal and chlorine tests will show the desired 1 3ppm free chlorine reading 11 Pcb displayed and all 4 red yellow LEDs are illuminated A possible Printed Circuit Board fault has been detected Troubleshooting Diagnostic Displays Sequential pushes of the small diagnostic button next to the LCD display will cause the Aqua Trol to display the following information 1 Pool temperature xx degrees Fahrenheit or Celsius 2 Cell voltage typically 22 0 to 26 0 volts when chlorine is being generated other wise 30 35V Cell current typically 2 50 to 4 00 amps when chlorine is being generated other wise 0 amps Desired Output OP 100P depending on knob position Instant salinity xxxx ppm or x xx grams Liter Product name sent to the display AL 6 signifies Aqua Trol STD AL 7 signifies Aqua Trol Return Jet 7 Software revision level rl xx Ww Dave On the 8th push of the button the display will revert back to the default salt display Also if the button is not pushed for 30 seconds the display will revert back to the standard sa
24. t test is completely accurate and the test results may vary from the salt level on the Aqua Trol display If salt level is low add salt according to chart on page 4 7 High Salt LED illuminated Check salt level in pool spa If salt level is too high lower salt level by draining some of the pool water out of the pool and replace with fresh water Continue until the salt concentration is at recommended levels 8 Inspect Cell LED flashing Inspect and clean cell according to directions on page 8 When done press the diagnostic button for 3 seconds to stop the Inspect Cell LED flashing 9 Inspect Cell LED illuminated Remove and inspect the cell for scale If the cell is scaled follow the directions on page 8 for cell cleaning If the pool has the proper amount of salt and the Inspect Cell LED is still illuminated the cell may be worn and need replacement 10 Possible causes of little or no free chlorine residual Aqua Trol switch in OFF position Desired Level adjustment setting is too low Low stabilizer Cyanuric Acid Filter pump switched off or filter pump time too short 8 hours for average size pools more for large pools Salt level too low below 2500 ppm Low Salt LED on Salt level too high High Salt LED on Very warm pools increase chlorine demand increase Desired Level or filter run time Cold water below 50F causes Aqua Trol to stop generating Generating LED flashing Exces
25. y are closely supervised at all times e A green colored terminal marked Earth Ground is located inside the wiring compartment To reduce the risk of electric shock this terminal must be con nected to the grounding means provided in the elec tric supply service panel with a continuous copper wire equivalent in size to the circuit conductors sup plying the equipment One bonding lug for US models two for Canadian models is provided on the external surface To reduce the risk of electric shock connect the local common bonding grid in the area of the swimming pool spa or hot tub to these terminals with an in sulated or bare copper conductor not smaller than 8 AWG US 6 AWG Canada All field installed metal components such as rails ladders drains or other similar hardware within 3 meters of the pool spa or hot tub shall be bonded to the equipment grounding bus with copper con ductors not smaller than 8 AWG US 6 AWG Canada SAVE THESE INSTRUCTIONS LIMITED WARRANTY effective 04 01 09 Hayward Goldline warrants its Pro Logic and E Command pool automation products as well as its Aqua Rite Aqua Rite Pro Aqua Plus and SwimPure chlorination products to be free of defects in materials and workmanship under normal use and service for a period of three 3 years Hayward Goldline also warrants its Aqua Trol chlorination products to be free of defects in materials and workmanship under normal use and service for a perio