Home
User Manual - AAS Technology
Contents
1. 1 Camera Side Device e One 1 User Manual 24V DC 1A Single Power Adapter Sold Separately X VPoC24DC 04K e One 1 4 CH Video amp Power Over Coax Server e Four 4 Camera Side Devices e One 1 DB15 DVR Connector Cable 4 BNC e One 1 Power Cord with USA Plug Type e One 1 User Manual VPoC24DC 08K e One 1 8 CH Video amp Power Over Coax Server e Eight 8 Camera Side Devices e Two 2 DB15 DVR Connector Cables 4 BNC each cable e One 1 Power Cord with USA Plug Type e One 1 User Manual VPoC24DC 16K e One 1 16 CH Video amp Power Over Coax Server e Sixteen 16 Camera Side Devices e Two 2 DB15 DVR Connector Cables 8 BNC each cable e One 1 Power Cord with USA Plug Type e One 1 User Manual A Available Plug Types Australia For any returns please include all components listed above with original packaging in Resalable Condition Absolutely No Returns will be accepted if any component is missing damaged Features e Can run Coax Cable up to 300m 1000ft without power drop e Easy to upgrade to PTZ camera with existing 18 2 power wire to become data RS485 e No need to lay AC line and install power adapter to camera e 1cable for power and video transmission reducing the material cost e Enhanced anti interference capability Application Diagram 1CH A Gav DO ievoa mrve ez DCE GADA Fel T Coax Cable CAMERA WPOC2412DC VPOC24DC 01 ta CAMIS 300m 1000ft DVR A
2. Input 110 220V AC B gt Output 24V DC C Input 12V DC lication Diagram 4 8 16 CH SAV DO uwv WD Under 300m 1000ft b VPOC24DC 04 N eee VPOC24DC 08 VPOC24DC 16 Sma vrocaeia0c x4 x8 x16 A Input 110 220V AC B Output 24V DC C Input 12V DC A Technical Specifications Input Voltage Output DC Voltage Under 300m 1000ft when working with 4 8 16 CH DVR Transmitting Cable Video Connector Power Connector 24V DC Jack Video amp Power Transmission Dimension 64 L x 28 W x 21 H mm 2 52 L x 1 10 W x 0 83 H inches LxWxH with lead length 20 mm 10 24 inches 57g 2oz DVR Side VPOC24DC 01 VPoC24DC 04 VPOC24DC 08 VPoC24DC 16 Video Output Output DC 24V DC Voltage Output Rated 1 0A 3 2A 093 2A 4 5A 22 8 26 4V 8 8A 20 26 4V Current Range A A A Output ata 76 8W 108W 211 2W Power Ripple amp Noise Note 2 Voltage Adj Range Voltage Tolerance Note 3 Load Regulation 0 5 Note 5 500ms 500ms 30ms 230VAC 20ms 230VAC 1000ms 50ms 230VAC 1200ms 500ms 1000ms 50ms 115VAC 30ms 115VAC at 20ms 115VAC at at full load full load full load 50ms 230VAC 30ms 230VAC 20ms 230VAC Hela Up Time 10ms 115VAC at 25ms 115VAC at 16ms 115VAC at full Typ full load full load load 85 132V AC 90 132V AC Input Voltage 100 240V AC 85 264V AC 176 264V AC 180 264V AC Range 120 370V DC selected by switch selected by switch 248
3. any equipment loss sales or profits or delay or failure to perform this warranty obligation The remedies provided therein are the exclusive remedies under this warranty whether based on contract tort or otherwise MADE IN CHINA ri AAG Copyright 2013 by AAS Technology N 41C N 42 1K N 43 4K N 44 8K N 45 16K www AAS com tw 8 R201310 V28
4. 373V DC 254 370V DC PN 50 60 Hz 47 63 Hz Range Efficiency Typ 8H HT Input AC 0 8A 1 5A 115V AC 2A 115V AC 4 5A 115V AC Current 0 9A 230V AC 1 2A 230V AC 2 5A 230V AC mmen conse ostr Sa 5 Setup Rise Time Line Regulation 0 5 Note 4 S Leakage Current Overload Protection lt 2mA 240VAC lt 3 5mA 240VAC 105 150 rated 110 150 rated output power output power 27 6 32 4V Hiccup mode recovers automatically after fault condition is removed 20 C 60 C Refer to Derating Curve 20 C 50 C Over Voltage Protection Working Temp Working Humidity Storage Temp Humidity Temp Coefficient 20 90 RH non condensing 20 C 85 C 10 95 RH 0 03 C 0 C me 45 C 0 03 C 0 C 50 C 10 500Hz 2G 10min 1cycle period for 10 500Hz 3G 10min 1cycle 60min 60 h al X Y Z i lisi O atone each along X Y Z axes Safety UL60950 1 CB IEC60950 1 CCC GB4943 UL60950 1 approved Standards approved 40 C 85 C 10 95 RH Vibration Withstand I P O P 3KVAC I P FG 1 5KVAC O P FG 0 5KVAC Voltage Isolation Resistance EMC Emission Note 6 I P O P P FG O P FG 100M Ohms 500VDC 25 C 70 RH Compliance to EN55022 CISPR22 Class s Compliance to EN61000 4 2 3 4 5 6 8 11 EN55024 EN61000 6 1 light industry EMC Immunity Note 6 EMI Conduction amp Radiation level criteria A Des
5. ign refer to EN55022 CISPR22 Class A Design refer to EN61000 4 2 3 4 5 6 8 11 ENV50204 EN55024 light industry level criteria A 378 2K hrs min 320 7Khrs min 271 9K hrs min MTBF MIL HDBK 217F MIL HDBK 217F MIL HDBK 217F 25 25 C 25 C VB CI 64x28x21 mm Dimension 2 52x1 10x0 83 in 248x235x50 mm 248x235x50 mm 342 5x258x65 mm LxWxH with lead length 9 76x9 25x1 97 in 9 76x9 25x1 97 in 13 48x10 16x2 56 in 20 mm 10 24 in Weight 57g 20z 1 35kg 2 98 lbs 1 5 kg 3 3 Ibs 2 3 kg 5 07 Ibs m FE ce witching Certifications LISTED RoHS EMS Immunity Specifications are subject to change without notice Single Power Adapter sold separately A Switching Power Supply SPECIFICATION NOTES 1 All parameters NOT specially mentioned are measured at 230VAC input rated load and 25 of ambient temperature 2 Ripple amp noise are measured at 2OMHz of bandwidth by using a 12 twisted pair wire terminated with a 0 1uf amp 47uf parallel capacitor Tolerance includes set up tolerance line regulation and load regulation Line regulation is measured from low line to high line at rated load Load regulation is measured from 0 to 100 rated load The power supply is considered a component which will be installed into a final equipment The final equipment must be re confirmed that it still meets EMC directives For guidance on how to perform these EMC tests please refer to EMI testing of compone
6. nt power supplies as available on http www meanwell com S Limited Warranty m LIMITED ONE 1 YEAR WARRANTY AND EXCLUSIONS Manufacturer warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Manufacturer is free of defects in materials and workmanship under normal and proper use for one 1 year from the purchase date Manufacturer s only obligation is to correct such defects by repair or replacement at its option if within such one 1 year period the product is returned prepaid with proof of purchase date and a description of the problem This warrant excludes and there is disclaimed liability for labor for removal of this product or reinstallation This warranty is voided if this product is installed improperly or in an improper environment overloaded misused opened abused or altered in any manner or is not used under normal operating conditions or not in accordance with any labels or instructions There are no other implied warranties of any kind including merchantability and fitness or a particular purpose but if any implied warranty is required by the applicable jurisdiction the duration of any such implied warrant including merchantability and fitness of or a particular purpose is limited to one 1 year Manufacturer is not liable for incidental indirect special or consequential damages including without limitation damage to or loss of use of
7. ry AAC VPoC24DC 01K Red Logo VPoC24DC 01 VPoC2412DC X1 4CH 8CH 16CH Video Power over Coax Server with 12V DC Receiver Device Kit VPoC24DC 04K VPoC24DC 04 VPoC24120c X4 VPoC24DC 08K p Red Logo j TARE i TT VPoC2412DC X8 p Red Logo 1 VPoC24DC 16 VPoC24120c X16 USA VERSION Copyright 2013 by AAS Technology N 41C N 42 1K N 43 4K N 44 8K N 45 16K www AAS com tw R201310 V28 AN Please read the Manual before attempting to use this product Specifications and appearance are subject to change without notice CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT OPEN COVERS OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL Disposal of Old Electrical amp Electronic Equipment Applicable in the European WE Union and other European countries with separate collection systems This symbol on the product or on its packaging indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve na
8. tural resources For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product N Caution 1 Handle this product with care Avoid any shock or bumping of the product Improper handling could damage the product Do not handle the unit with wet hands Provide proper ventilation and air circulation and do not use near water Do not handle the product with wet hands 2 Reguires a proper operating environment This product is not waterproof and is designed for indoor use The allowable temperature range for operation of this product is between 20 C 50 C 3 Check the power source voltage The power source voltage should be within the specified range Product must meet the specifications 4 Objects and liguid entry Never push objects of any kind into this product as this may touch dangerous voltage points of short out parts that could result in a fire or electric shock Never spill any kind of liguid on the product 5 Cleaning Do not use liquid or aerosol cleaners to clean this unit Always unplug the power to the device before cleaning 6 Servicing Do not attempt to service this product by yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all service to qualified servicing personnel Package Contents A VPOC24DC 01K e One 1 1CH Video amp Power Over Coax e One
Download Pdf Manuals
Related Search
Related Contents
K 5.91 M - Kärcher FL02 - CEISA Ices IBT-1 442 User Guide Garamond.qxd FRENIC Multi_LM1_1.4.3 Guía del usuario de la cámara USER MANUAL FTH-508 取扱説明書 - 音羽電子システム株式会社 Husky11 Development Board Getting Started Manual Copyright © All rights reserved.
Failed to retrieve file