1.    1  Remote control   except for model PX11        PX11 U30   PX11 U36    www XtremeAirUsa com PAGE 5    INSTALLATION    15        120   Single Cutlet     amp  metal duct                      s 5    Flush with the front    frame of cabinet       Figure 5    A  PREPARE DUCTWORK  amp  SINGLE OUTLET    Make sure you have a 15amp  120V  60Hz  single outlet on the  left or right of the duct pipe  usually is on 74 of cabinet width   See  Figure 1    Make sure duct pipe is ready to hook up to the range hood before  beginning installation  8  diameter duct  and roof or wall cap   depending on where you will be venting your hood     NOTE  Use threaded drywall anchors only when mounting the hood on  sheet rock  Mounting the hood on wall studs or lumbers is highly  recommended     B  INSTALL THE HOOD BODY UNDER A CABINET     1  Puta thick  protective covering over counter top  cook top or range  to protect from damage or dirt     TIP  optional    you can create a solid flat form by having 2 solids 2 3  block  at both side of stove and a 3 4  1  plywood flat form above  Figure 2    2  For installing under the cabinet with recessed bottom  attach 4 inch  wide wood filler strips  not provided  on each side  Refer to below  figure 3    3  Create access opening for electrical wires and hood exhaust under  the cabinet  Figure 4    15amp  120v 8  Lift the hood up and have it         uer place below the cabinet  Make  sure center the hood beneath the  cabinet and flush with the front of  the c
2.  Never allow the filters to become blocked or  clogged  Do not allow foreign objects  such as cigarettes or napkins  to be sucked into the hood     WARNING  TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE   m Never leave surface units unattended at high settings  Boil overs cause smoking and greasy spillovers  that may ignite  Heat oils slowly on low or medium settings   m Always turn hood ON when cooking at high heat or when greasy food   m Clean ventilating fans frequently  Grease should not be allowed to accumulate on fan or filter   m Use proper pan size  Always use cookware appropriate for the size of the surface element     WARNING  TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE   OBSERVE THE FOLLOWING   m SMOTHER FLAMES with a close fitting lid  cookie sheet  or metal tray  then turn off the burner  Be careful  to prevent burns  If the flames do not go out immediately  EVACUATE AND CALL THE FIRE DEPARTMENT   m NEVER PICK UP A FLAMING PAN   you may be burned   m DO NOT USE WATER  including wet dishcloths or towels   a violent steam explosion will result   m Use an extinguisher ONLY if       You know you have a class ABC extinguisher  and you already know how to operate it       The fire is small and contained in the area where it started       The fire department is being called       You can fight the fire with your back to an exit     www XtremeAirUsa com PAGE 3    HEIGHT  amp  VENTING REQUIREMENT  CLEARANCE  IMPORTANT    e NEVER exhaust
3.  air or terminate duct work into spaces between walls   crawl spaces  ceiling  attics or garages  All exhaust must be  ducted to the outside    e Hood mounted too low could result in heat damage and fire hazard   while hoods mounted too high will be hard to reach and will loose its  performance and efficiency    e Use metal duct work only  Rigid metal vent is recommended       minimum of 8  round  standard for this range hood  purchased  separately must be used to maintain maximum airflow efficiency   e DO NOT use plastic vent    e DO NOT use 4   10 2 cm  laundry type wall caps   e Fasten all connections with sheet metal screws and tape all joints with  aluminum tape    e Use caulking to seal exterior wall or roof opening around the cap    e  he vent system must have a damper  If roof or wall cap has a  damper  do not use damper supplied  for some models only  with the  range hood     For the most efficient  amp  quiet operation       A distance of 26    to 30    is recommended between stove top and the  bottom of range hood    e tis recommended that the range hood be vented vertically through  the roof through 8  or bigger vent work    e ALWAYS  when possible  reduce the number or transitions and turns   If long duct run is required  increase duct size from 8  to 9  or 10   If a  reducer is used  install a long reducer instead of a pancake reducer   Reducing duct size will restrict airflow and decrease airflow  thus  reduce duct size as far away from opening as possible    e
4.  lf turns or transitions are required  Install as far away from opening  and as far apart  between 2  as possible    e The size of the vent should be uniform    e Use      more than three 90   elbows    e          sure there is a minimum of 24   61 cm  of straight vent between  the elbows if more than one elbow is used        VENTING METHODS  e DONOT install two elbows together             Open 2  Vertical roof venting  CABINET fi           e   lt                       fee     Y CABINET Ez         Side wall cap          CABINET    www XtremeAirUsa com PAGE 4    ELECTRICAL REQUIREMENTS     IMPORTANT  Observe all governing building codes and city ordinances   m A 120 volt  60 Hz   AC only  15 amp  fused electrical circuit is required   It is the customer s responsibility   e Tocontact a qualified electrical installer   e      assure that the electrical installation is adequate and in conformance with National Electrical Code  ANSI   NFPA 70     latest edition   or CSA Standards C22  1 94  Canadian Electrical Code  Part 1 and C22  2 No  0     M91   latest edition   and all local codes and ordinances     TOOL YOU WILL NEED    Maker or pencil   Stud finder   Measuring tape   Powered screwdriver or drill   Flat  amp  Phillips screwdrivers       evel   Drill with 174    1 4   7 9 mm  drill bits    Jigsaw or keyhole saw HOOD DIMENSIONS     PARTS SUPPLIED                     1  Instruction manual book    LL ATION GOR d VELES    Baffle Filters        Grease Tunnel    ir     1  Screws  
5.  or explosive vapors and  liquids  such as gasoline  inside or in the vicinity of this or any other appliance  Keep items that could explode  such  as aerosol cans  away from cook top burners  ovens and range hoods  Do not store flammable or explosive  materials in adjacent cabinets or surrounding areas     Disclaimer  7he manufacturer and or distributor reseller decline all responsibility in the event of failure to observe  the instructions provided for installation  maintenance and suitable use of the product  The manufacturer and or  distributor reseller shall NOT be responsible for any injury due to negligence and the warranty of the unit shall  automatically be voided due to failure to observe proper safety and installation procedures  The manufacturer  and or distributor reseller will not be held responsible for any damages to personal property or real estate or any  bodily injuries whether caused directly or indirectly by the range hood     www XtremeAirUsa com PAGE 2    IMPORTANT SAFETY INSTRUCTIONS continue          WARNING   TO REDUCE THE RISK OF FIRE  ELECTRIC SHOCK  OR INJURY TO PERSONS  OBSERVE  THE FOLLOWING      Use this unit only in the manner intended by the manufacturer  If you have questions  contact the manufacturer    PRODUCT  Do not remove permanently affixed labels  warnings  or plates from the product  This may void the  warranty  Do not try to alter the hood    INSTALLATION  The installation in this manual is intended for qualified installers  service
6.  technicians or persons  with similar qualified background  Installation and electrical wiring must be done by qualified professionals and  in accordance with all applicable codes and standards  including fire rated construction  When cutting or  drilling into wall or ceiling  do not damage electrical wiring and other utilities  Due to the size and weight of this  range hood  two people installation is recommended  Range hood may have very sharp edges  please wear  protective gloves if it is necessary to remove any parts for installing  cleaning or servicing     VENTTING  For kitchen range or cook top ventilating use only  DO NOT use to exhaust hazardous or  explosive materials and vapors  Ducted fans MUST always be vented to the outdoors  DO NOT vent exhaust  into spaces between walls  crawl spaces  ceiling  attics or garages  Use only metal ductwork  Old duct work  should be cleaned or replaced if necessary to avoid the possibility of a grease fire  Check all joints on duct  work to insure proper connection and all joints should be properly taped     ELECTRICAL  All electrical wiring must be properly installed  insulated and grounded  Before servicing or  cleaning unit  turn power OFF and un plugged    OPERATION  Use high settings on cooking range only when necessary  Keep all fan  baffle  spaces  filter   grease tunnel  oil container and grease laden surfaces clean  Grease should not be allowed to accumulate on  fan  baffle  spaces  filter  grease tunnel and oil container 
7. 2 U36   ONLY       LCD E 1  Light Eun Decrease  PowerOf Increase  Delay Auto Functior  Remote Control          aa    Sensor    Note  This range hood is equipped with remote control and smoke sensor that will self calibrate within 5 seconds when  the range hood is first electrically activated  Self calibration will be set when the range hood beeps  LCD panel will turn  off automatically after a period of inactivity     IMPORTANT  This a touch sensitive control  please DO NOT PRESS the button but TOUCH it     A  Activating Normal Blower Function       While the range hood is off   e o Touch     to start from lowest speed  F1  Touch     to start from Highest speed  F4  Touch     or     again to change the blower speed as indicated in LCD panel  Decrease 00   blower off    Incense        quiet speed    B  Activating Light Fundtiom  ow speed       medium speed    e Touch Lt buttospeedurn the lights on or off        Light    C  Activating Power Off Delay Function        1  While the range hood is on and the blower is running in normal mode  touch Power Off  Delay button to activate delay off timer   2  Adjust to desired period of delay off timer by touching     or     button  1 15 minutes    Power Off Timer beings to countdown immediately  when it reaches 0  the blower will shut off   Delay    D  Activating Smoke Detector Function             While the machine is off  touch Auto Function button to activate the smoke detector auto function   mode   NOTE  this function is only work w
8. QMKtremeAIR     The Advanced Range Hoods       INSTALLATION GUIDE  amp  USER   S MANUAL    PRO X SERIES    Under Cabinet Range Hood    Model  R130   PX10 U30  R136   PX10 U36  PX11 U30   PX11 U36   R230   PX12 U30   R236   PX12 U36          IMPORTANT  READ AND SAVE THESE INSTRUCTIONS    FOR RESIDENTIAL  amp  INDOOR USE ONLY    www XtremeAirUsa com PAGE 1    TABLE OF CONTENTS    IMPORTANT SAFETY INSTRUCTIONS  HEIGHT  amp  CLEARANCE REQUIREMENT  VENTING REQUIREMENT   VENTING METHODS   ELECTRICAL REQUIREMENT   TOOL NEEDED   PART SUPPLIED   RANGE HOOD DIMENSIONS  INSTALLATION   RANGE HOOD OPERATION  SPECIFICATION   REPLACING THE LIGHT BULB  TROUBLE SHOOTING   USE  amp  CARE    1  2  3  4  5  6  7  8  9                   A    N              IMPORTANT SAFETY INSTRUCTIONS          IMPORTANT NOTICE  The Important Safety Intructions and warnings in this manual are not meant to cover all  possible problems and situations that can occur  Please also use common sense and caution when installing   maintaining or operating this or any other appliance  Please always contact the XtremeAir USA  LLC  Customer  Support Team at 1 714 554 9000 or email  support XtremeAirUsa com with any problems or situations that you  do not understand    The manufacturer disclaims all liability for any damage or injury caused as a result of not following  instructions for installation contained in the following text        To avoid the possibility of explosion or fire  do not store or use combustible  flammable
9. Replacing Filters     Should filters wear out due to age and prolonged use  please contact your local reseller for replacement filters     Note  Also replace damaged filter that has punctured or broken mesh  bent or broken frame     WWW XtremeAirUsa com PAGE 12    
10. abinet     8  metal duct    TIP  optional   since the hood is  heavy  use cabinet jack is highly  recommended it  See figure 5 5    Figure 5 5    WWW XtremeAi1irUsa com PAGE 6    9  From inside of the hood  place screws into the exact center of each  knockout holes  4  and secure to cabinet bottom  Finish tightening all  screws until secure  Be careful when using electrical screwdriver   damage to the range hood may occur     gure 6    10  Secure the hood by using 1 5        2 0    wood screws  the screws  are not provided  screw through the back of hood to the studs   use stub finder to find the stud  Figure 7    CAUTION  Make certain the range hood is secure before releasing     11  Connect the exhaust on the hood to the ductwork above  Use  aluminum tape to make all joints secure and all tight    Figure 7       C  INSTALL OIL TUNNEL  amp  BAFFLE FILTER  1  OIL TUNNEL    Drop oil tunnel into recess support near rear of hood  Refer to  below figure A      Figure      Oil Tunnel Side View    2  BAFFLE FILTERS        Install baffle filters  refer to Figure B on the left for the following three    BACK  steps        1  Angle baffle filter toward back of hood    2  Lifta baffle filter up above horizontal level    3  Slide forward into slot behind the front of hood   To remove the baffle  please reverse the process              Figure B  Baffle Instllation Side    www XtremeAirUsa com PAGE 7    RANGE HOOD OPERATION    1  TYPE 1  FOR PX10 U30  PX10 U36  R230   PX12 U30  R236   PX1
11. ep fryers during use  Superheated oil may be  flammable     Cleaning     The saturation of greasy residue in the blower and filters may cause increased inflammability  Keep unit clean  and free of grease and residue build up at all times to prevent possible fires    FILTERS MUST BE CLEANED PERIODICALLY AND FREE FROM ACCUMULATION OF COOKING  RESIDUE  Old and worn filters must be replaced immediately    DO NOT operate blowers when filters are removed  Never disassemble parts to clean without proper instruc     tions  Disassembly is recommended to be performed by qualified personnel only  Read and understand all  instructions and warnings in this manual before proceeding     MAINTENANCE     SAFETY WARNING  Never put your hand into area housing the fan while the fan is operating   For optimal operation  clean range hood and all baffle spacer filter grease tunnel oil container regularly  Regular care  will help preserve the appearance of the range hood     Cleaning Exterior surfaces     Clean periodically with hot soapy water and clean cotton cloth  Do not use corrosive or abrasive detergent   e g  Comet Power Scrub   EZ Off   oven cleaner   or steel wool scoring pads  which will scratch and  damage the stainless steel surface  For heavier soil use liquid degrease such as  Formula 409   or   Fantastic   brand cleaner    If hood looks splotchy  stainless steel hood   use a stainless steel cleaner to clean the surface of the hood   Avoid getting cleaning solution onto or into the co
12. es   This setting will be saved immediately     D  Activating the timer function   1  While the blower  motor  is running  touch and hold Power button for over 3 seconds to activate    delay off timer  Power off delay indicator will lit up and power off delay digital timer will begin to  countdown  when it reaches zero  the blower  motor  will shut down     E  To clear cleaning reminder     e When blower  motor  starts to rotate  cumulative running time will be shown in Power On  Elapsed Digital Timer  This timer icon flashes when 30 hours is up and reminds user to clean  the baffle filters    e After cleaning the filters and when the motor is not in use  touch and hold     Increase Value  button over 3 seconds to reset the timer  Please note that turning off the system will not reset  the Power On Elapsed Digital Timer     F  AUTOMATIC SHUT OFF   e MACHINE WILL AUTOMATICLY SHUT OFF AFTER OF APP  2 7  HOURS  FOR THOSE MANUFACTURED  AFTER AUGUST 2012 ONLY     SPECIFICATION     Body Design Seamless Stainless Steel  Satin Finish  Power Rating 120V 60Hz  USA  amp  Canada standard   General Input Power 184W  90W   2x2W    90 W each  Number Of Motors    Venting Size Top  8 inches Round    Interference Protection Radio Frequency Interference Protected    opecification subject to change without notice  contact your local reseller for details   Note  REPLACING THE LIGHT BULB          1  Make sure the range hood is unplugged or turn OFF  breaker    2  Use the small flat crew driver to 
13. hen there   s a lot of smoke  Once this button is touched or  Auto Function touched  all other button is deactived     E  Remote Control Sensor     www XtremeAirUsa com PAGE 8    1  Remote control sensor receives infrared  IR  signal from the remote control   The maximum distance for IR data transmission is 3 meter and requires direct  line of sight  The transmission distance may vary depending on temperature and  remote control battery condition   NOTE        1  Light settings are independent from other settings  including power off delay   ir CHER and lights have to be manually turned on or off    Em  2  The system saves user configurations  settings such as light  timer and blower   motor  speed will remain the same the next time it is turned on     2  TYPE 2  FOR PX11 U30  PX11 U36  ONLY       Control Panel Layout and Buttons                         _   1    0 Power Light  6   2  Decrease Value Increase Value    6  Blower Power Indicator Power On Elapsed Digital Timer  8     Blower Speed Indicator Power Off Delay Digital Timer 9     Light Power Indicator Power Off Delay Timer Indicator ao     For           amp  PX03 Model    NOTE  For best results  start the range hood before cooking and allow it to operate several minutes after  the cooking is completed to clear all smoke and odors from the kitchen    Button functions     1   To power ON OFF the range hood  and to activate power off delay timer     2  To decrease blower  motor  speed  decrease timer value  and enter time
14. lift any where  around the outsider ring as show in below picture  Arrow    3  Install new light bulb   4  Put back the light set by press it in    5  Turn ON breaker and range hood to test for  operation     WWW XtremeAirUsa com PAGE 10    TROUBLE SHOOTING    1  If the range hood or lights does not operate  after installation     2  The range hood vibrates when the blower is  on     3  The blower or fan seems weak     4  The lights work but the blower is not spinning    at all  is stuck oris rattling     5  The hood is not venting out properly     6  the hood is noisy than normaldfd    7  Control panel is not active    8  Remote control is not working    Check if the range hood has been plugged in  make  sure that all power has been turned back ON  the  fuse is not blown and all electrical wiring is  properly connected    Swap out light assembly to working ones to detere  mine whether it 1s caused by defective bulbs  See  replacing the light bulbs on Page 17     The range hood might not have been secured prop   erly on to the ceiling or wall    Check if the motor is secured in place  If not   then tighten the motor in place    Check if the blower wheel is a damaged     Check that the duct sized used is at least 8   Range  hood WILL        function efficiently with  insufficient duct size  amp  loosely secured    Check if duct is clogged or if damper unit  half cir   cular flapper  is not installed correctly or opening  properly  A tight mesh on a side wall cap unit  might al
15. ntrol panel  Follow directions of the stainless steel cleaner   CAUTION  Do not leave on too long as this may cause damage to hood finish  Use soft towel to wipe off the  cleaning solution  gently rub off any stubborn spots  Use dry soft towel to dry the hood    After cleaning  you may use non abrasive stainless steel polish such as 3M    or ZEP    to polish and buff out  the stainless luster and grain  Always scrub lightly  with clean cotton cloth  and with the grain    DO NOT allows deposits to accumulate or remain on the hood    DO NOT use ordinary steel wool or steel brushes  Small bits of steel may adhere to the surface and cause  rusting    DO NOT allow salt solutions  disinfectants  bleaches  or cleaning compounds to remain in contact with  stainless steel   for extended periods  Many of these compounds contain chemicals  which may be harmful   Rinse with water after exposure and wipe dry with a clean cloth     Cleaning Aluminum Grease Filter   Stainless Steel Filter less Grill   IMPORTANT  Drain oil from oil containers before oil and residue overflow     The metal filters fitted by the factory are intended to filter out residue and grease from cooking  It need not be  replaced on a regular basis but are required to be kept clean    Filters should be cleaned after every 30 hours of use    Remove and clean by hand or dishwasher  Spray  Formula 4099  or equivalent degreasing detergent and  leave to soak if heavily soiled  Dry filters and re install before using hood     
16. r mode     7  To increase blower  motor  speed  increase timer value  and cumulative timer reset    3  Lights up when blower  motor  is running     4  Shows current blower  motor  speed  1 4      5  Lights up when lights turned on     6  To turns ON OFF lights     8  Indicates the accumulated time the system is running     9  Indicates the length of time left for delay off function     10  Lights up when auto shutdown delay timer function is on     A  Adjusting the blower  motor  speed     1  Touch  1  Power button once   to turn on the system  The Blower Power Indicator icon  flashes showing that the blower  motor  is ready    2  Decrease Value button will decrease the speed of the blower  motor  from 4 to 1  strongest to  quietest   Increase Value button will increase the speed of the blower  motor  from 1 to 4   quietest to strongest    Touch Power button once to turn off the system    Note  The system saves user configurations  settings such as light  timer and blower  motor  speed will re   main the same the next time it 1s turned on     B  To turn the light on   1  Touch Light button once to turn on the lights  and once again to turn off the lights     www XtremeAirUsa com PAGE 9    C  Adjusting the timer function   1  While the blower  motor  is not running  touch and hold Decrease Value button over 3    seconds to enter timer mode   2  Adjust to desired period of delay off timer by touching Increase Value or Decrease Value  button  minimum 1 minute to maximum 15 minut
17. so cause restriction to the air flow     The blower might be jammed or scraping the bot   tom due to shipping damage  Please contact us im   mediately   The motor is defective  possibly seized   change  the motor     Make sure the distance between the stove top and  the bottom of the hood is within 26  and 30  in  distance  Due to different ceiling height configura   tions  recommended height may not be applicable   Reduce the number of elbows and length of duct  work  Check if all joints are properly connected   sealed  and taped    Make sure the power is on high speed for heavy    cooking    The duct 1s not secure cause variation  The wrong duct size is using smaller than required  Check to make sure the auto function 1s not on    Check to make sure the plastic film was removed     www xtremeAirUsa com PAGE 11    USE  amp  CARE INFORMATION     Operations     Read and understand all instructions and warnings in this manual before operating the appliance  Save these  instructions for future reference    Always leave safety grills and filters in place  Without these components  operating blowers could catch on to      hair  fingers and loose clothing    NEVER dispose cigarette ashes  ignitable substances  or any foreign objects into blowers    NEVER leave cooking unattended  When frying  oil in the pan can easily overheat and catch fire  The risk of  self combustion is higher when the oil has been used several times    NEVER cook on  open  flames under the range hood  Check de
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Legacy Car Audio LA-1478 Car Amplifier User Manual  Ethernet Open Connectivity via Modbus/TCP  User Manual  0°1 - 750ACE.com  取扱説明書  こちら  User Manual  Macintosh Arabic Language Kit Installation and User`s  ICP-portuguese 771076020  cg3-uv    Copyright © All rights reserved. 
   Failed to retrieve file