EOS System Message Guide

image

Contents

1. EOS User Manual 78 CHAPTER 2 SYSTEM MESSAGES RELOAD DELAY ENDING Mlag reload delay period swill end in s seconds Severity Info Explanation Non peer link interfaces will be enabled once reload delay period is over Recommended Action No action is required this message is for information only STATE_INACTIVE_CONNECTION CLOSED MLAG is inactive with peer s because the TCP session was closed Severity Error Explanation The TCP connection between the MLAG processes was broken Recommended Action Check the health of both Mlag agents Test and troubleshoot IP connectivity e g ping the configured MLAG peer address STATE INACTIVE FWD AGENT RESTART MLAG is inactive with peer s because the forwarding agent restarted Severity Info Explanation The forwarding agent restarted causing the peer relationship to end Recommended Action No action is required this message is for information only STATE_INACTIVE_HEARTBEAT_TIMEOUT MLAG is inactive with peer s because it stopped receiving heartbeats from the peer Severity Error Explanation The TCP connection between the peers is intact but no heartbeat was received from the peer during the expected duration Recommended Action Check the health of both Mlag agents Test and troubleshoot IP connectivity e g ping the configured MLAG peer address STATE_INACTIVE HW NOT READY MLAG is inactive because the hardware is not ready Severity Error Explanation Har
2. 2 79 STAGEMGR Messages FATAL ERROR REBOOT REQUEST Agent s encountered a fatal error The system will restart now s Severity Error Explanation One or more agents has encountered a problem The system will now save diagnostic information and do a normal reload to fix the problem Recommended Action The system has generated diagnostic information to help pinpoint the failure Please contact your technical support representative to find out how to send this information to Arista PERSISTENT_RESTART_LOG_REQUEST Agent s encountered a non fatal error prior to reload s Severity Warning Explanation An agent encountered a problem prior to restarting the system Recommended Action No action is required this message is for information only STAGE COMPLETE AFTER TIMEOUT s resumed after stage s completed after timeout Severity Warning Explanation A stage that had been taking longer than expected to complete has now completed Stages that depend on this completion are able to proceed Recommended Action No action is required this message is for information only STAGE_SLOW s stage s timed out Severity Warning Explanation A stage in progression is taking longer than expected Stages that depend on this stage will begin after this stage is completed Recommended Action No action is required this message is for information only EOS User Manual 138 CHAPTER 2 SYSTEM MESSAGES 2 80 STRATA Messages
3. CHAPTER 2 SYSTEM MESSAGES SYSTEM_UNSUPPORTED Fru management software is not installed for this system code d Severity Emergency Explanation The current hardware is not supported by the running Fru Agent software System functionality is severely limited Recommended Action Install new software and restart the Fru Agent TRANSCEIVER INSERTED A transceiver for interface s has been inserted manufacturer s model s part number s rev s serial number s Severity Info Explanation Transceiver insertion detected Recommended Action No action is required this message is for information only TRANSCEIVER REMOVED The transceiver for interface s has been removed Severity Info Explanation Transceiver removal detected Recommended Action No action is required this message is for information only EOS User Manual 42 CHAPTER 2 SYSTEM MESSAGES 2 23 FWK Messages ELB_MEMORYLIMITEXCEEDED AttrLog buffer memory limit exceeded s s Severity Error Explanation A runtime subsystem memory limit was reached Recommended Action Please contact technical support FAILED TO INSTANTIATE Unable to instantiate entity s requested by peer s at s Severity Warning Explanation The runtime subsystem was unable to instantiate an entity requested by a peer process It is possible that incompatible library versions are in use Recommended Action This is likely a serious error Please contact technical support
4. 2 88 VMTRACERSESS Messages ADD_VMENTRY VM s nic s mac s portgroup s vlan s switch s host s datacenter s intf s Severity Info Explanation A new VM has been added to the VM Tracer database Recommended Action No action is required this message is for information only DEL_VMENTRY VM s nic s mac s portgroup s vlan s switch s host s datacenter s intf s Severity Info Explanation VM has been deleted from VM Tracer database Recommended Action No action is required this message is for information only RESTART_CONFIG Agent restart due to configuration change Severity Info Explanation VmTracerSess agent is restarting due to configuration change Recommended Action No action is required this message is for information only EOS User Manual 155 CHAPTER 2 SYSTEM MESSAGES 2 89 VMWAREVI Messages AGENT RESTART Agent restarting due to network error Severity Error Explanation This error indicates that there was loss of connectivity after a session was successfully established and the agent is restaring Recommended Action If the problem persists contact your support representative Otherwise no action is required COMMUNICATION ERROR Loss of connectivity to vCenter Severity Error Explanation This error indicates that there was loss of connectivity after a session was successfully established with vCenter Recommended Action If the problem persists contact your support representativ
5. 40G MODE CHANGE Change in interface configuration from 10G to 40G or vice versa the StrataAgent will restart Severity Info Explanation When a QSFP port is reconfigured from 4x10G to 1x40G or vice versa the switch ASIC must be reconfigured requiring the StrataAgent to restart Recommended Action This behavior is expected AGENT_RESTART Strata agent requires to be restarted due to an unrecoverable exception s Severity Error Explanation An exception has occurred on the switch StrataAgent will be restarted Recommended Action No action is required this message is for information only CONFIG CHANGE Configuration change requires the Strata agent s to restart Severity Info Explanation Configuration change requires the switch ASIC to be reconfigured requiring the Strata agent to restart Recommended Action No action is required this message is for information only FABRIC LINK ERR DISABLED Fabric link s is disabled due to errors s Severity Error Explanation Fabric interface is disabled when its link fails to come up or there are too many flaps Recommended Action Remove and re insert linecard or fabric card the impacted fabric link connects to FABRIC_LINK_FLAP Fabric link s is flapping Severity Warning Explanation Link on fabric interface comes up and down while connected to its peer interface Recommended Action Remove and re insert linecard or fabric card the impacted fabric link connects to HARDW
6. Explanation When a QSFP port or SFP port is enabled or disabled the switch ASIC must be reconfigured requiring the StrataA gent to restart Recommended Action No action is required this message is for information only EOS User Manual 140 CHAPTER 2 SYSTEM MESSAGES RESERVED_HOST_TABLE_EXCEEDED The reserved value chosen for the host entries exceeds the current number of available entries Reserving only d entries Severity Info Explanation The number of entries reserved in the host table cannot exceed the current table capacity The actual number of entries reserved is lower than the configured one Recommended Action No action is required this message is for information only RXDMASTUCKERROR RX Packet DMA Stuck Error occurred in StrataAgent chip s Severity Error Explanation A fatal PCIE Error affecting cpu packet DMA occurred in a Strata switching ASIC Strata agent restarted in order to recover from this error Recommended Action No action is required this message is for information only SCHEDULER_MODE_CHANGE Switch scheduler configuration changed to s the forwarding agent will restart Severity Info Explanation When the switch scheduler configuration is changed the switch ASIC must be reconfigured requiring the forwarding agent to restart Recommended Action No action is required this message is for information only SYSTEM_RESET All switches restarting Cause s Severity Info Expl
7. INSTANTIATE_READONLY Instantiation of s requested by read only peer s at s Severity Warning Explanation The runtime subsystem refused to instantiate an entity requested by a peer process that mounted the parent read only Recommended Action Please contact technical support MOUNT_CLOSED_ EXIT Process exiting Severity Error Explanation A runtime subsystem lost contact with a peer process Recommended Action Please contact technical support MOUNT PEER CLOSED Peer closed socket connection s s Severity Error Explanation A runtime subsystem lost contact with a peer process Recommended Action Please contact technical support SOCKET_CLOSE LOCAL Closing connection to s at s s Severity Error Explanation A runtime subsystem lost contact with a peer process Recommended Action Please contact technical support SOCKET_CLOSE_REMOTE Connection to s at s closed by peer s Severity Error Explanation A runtime subsystem lost contact with a peer process Recommended Action Please contact technical support EOS User Manual 43 CHAPTER 2 SYSTEM MESSAGES 2 24 GMP Messages IGMP QUERY VERSION CONFIGURED DISCREPANCY IGMP version d query heard on vlan d by a querier configured to version d Severity Warning Explanation The switch detected an IGMP query message of a different version than the version that is currently configured Recommended Action Configure all queriers on the network to us
8. Recommended Action No action is required this message is for information only MAX_PATHS_EXCEEDED Number of paths d for adj d higher than max supported value d Severity Error Explanation The system is trying to allocate an ecmp route with more paths than the maximum allowed by the hardware The route cannot be allocated Recommended Action No action is required this message is for information only URPF_IPV4_CONFLICT IPv6 Unicast RPF on s disabled conflicts with IPv4 Unicast RPF Severity Warning Explanation IPv6 Unicast RPF on the listed interface is disabled because it conflicts with IPv4 Unicast RPF on the interface Recommended Action No action is required this message is for information only URPF IPV4_NO_CONFLICT IPv6 Unicast RPF on s re enabled Doesn t conflict with IPv4 Unicast RPF Severity Warning Explanation Pv6 Unicast RPF on the listed interface is re enabled because it no longer conflicts with IPv4 Unicast RPF on the interface Recommended Action No action is required this message is for information only EOS User Manual 61 CHAPTER 2 SYSTEM MESSAGES 2 30 IRA Messages RELOAD HITLESS INTF_CONFIG RESTORATION TIMEOUT Timed out waiting for IP configuration to be applied on all interfaces Severity Warning Explanation This may result in some traffic disruption during ASU Recommended Action No action is required this message is for information only RELOAD _HITLESS
9. Severity Emergency Explanation The specified transciever has begun to overheat Recommended Action Check that system fans are operating correctly If the problem persists please contact your support representative for assistance XCVR_TEMP NORMAL s temperature has returned to normal Severity Emergency Explanation The specified transciever was overheating but has now returned to a normal operating temperature Recommended Action No action is required this message is for information only EOS User Manual 27 CHAPTER 2 SYSTEM MESSAGES 2 16 ETH Messages ARP_CACHE CLEAR ARP cache cleared by s on s s Severity Notice Explanation ARP cache cleared by CLI command Recommended Action No action is required this message is for information only AUTONEGUNSUPPORTED Auto negotiation is unsupported on interface s link mode speed and duplex will be forced to s mode instead Severity Warning Explanation The interface is configured to auto negotiate but the transceiver currently inserted does not support auto negotiation The switch will attempt to bring up the link with a forced configuration as indicated in the message Recommended Action Configure the interface to use one of the supported link modes or replace the transceiver with one that supports the configured link mode CONGESTION_DROPS Interface s is experiencing congestion drops s Severity Info Explanation The interface s frame buffer lim
10. Severity Error Explanation An error occurred when trying to write to EventMon Database Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved EOS User Manual 32 CHAPTER 2 SYSTEM MESSAGES 2 18 EXTENSION Messages INSTALLED Extension s has been installed Severity Info Explanation The extension has been installed Recommended Action No action is required this message is for information only INSTALLING Installing extension s version s SHA 1 s Severity Info Explanation EOS has started to install the extension Recommended Action No action is required this message is for information only INSTALL ERROR Extension s failed to install s Severity Error Explanation The extension failed to install The log message may contain a reason why installation failed such as a missing dependency Recommended Action Determine why the extension failed to install If a dependency is missing install it If you are unsure how to proceed contact the developer of the extension or your support representative UNINSTALLED Extension s has been uninstalled Severity Info Explanation The extension has been uninstalled Recommended Action No action is required this message is for information only UNINSTALLING Uninstalling extension s Severity Info Explanat
11. Severity Error Explanation The switch is unable to program QoS policy map configuration due to insufficient hardware resources Recommended Action Reduce number of ACL rules in policy map classes or reconfigure your ACLs to free some resources for policy maplf there is a policer in one of the classes detaching policy map from one of the interfaces also frees up resourcs EOS User Manual 104 CHAPTER 2 SYSTEM MESSAGES POLICY HW RESOURCE NORMAL Programmed s policy map s in hardware Severity Error Explanation The switch was able to program entire policy map configuration in the hardware Recommended Action No action is required this message is for information only POLICY_MULTIPLE_ACTIONS Multiple actions are attached to the class map s in the policy map s Severity Error Explanation In case of conflicting actions only a single action is applied Dscp rewrite is programmed over any other action cos rewrite is programmed over traffic class selection Recommended Action Reconfigure policy map and specify only one action per class POLICY POLICER RESOURCE FULL Insufficient hardware resources to program the police action for the class map s in the policy map s on s s Severity Error Explanation Remove some features using policer banks and reapply the policy map to the interface to enable police action Recommended Action No action is required this message is for information only SCH_SHP_UNIT_MISMATCH
12. Severity Notice Explanation Exec accounting message Recommended Action No action is required this message is for information only SYSTEM s task id d start_time d timezone s service s event s reason s Severity Notice Explanation System accounting message Recommended Action No action is required this message is for information only EOS User Manual 7 CHAPTER 2 SYSTEM MESSAGES 2 3 ACL Messages HW RESOURCE FULL Hardware resources are insufficient to program all ACLs s Severity Error Explanation The switch is unable to program all ACLs due to insufficient hardware resources Recommended Action Reconfigure your ACLs to reduce the size and or complexity of the ACL HW_RESOURCE_NORMAL All ACLs are programmed in hardware s Severity Error Explanation The switch was able to program all the ACLs in the hardware Recommended Action No action is required this message is for information only IP6ACCESS list s s s s Ps Yos s Severity Info Explanation A packet has matched one of the rules with log option in the specified IPv6 access list Recommended Action No action is required this message is for information only IPACCESS list s s s s Severity Info Explanation A packet has matched one of the rules with log option in the specified IP access list Recommended Action No action is required this message is for information only IPV6_ERACL_ROUTEDPORT The
13. list NOTIF s Severity Info Explanation MVRP notification Recommended Action No action is required this message is for information only VLAN JOIN VLAN Join for d s on s Severity Info Explanation MVRP Vlan Join message was transmitted received on an interface Recommended Action No action is required this message is for information only VLAN LV VLAN Leave for d s on s Severity Info Explanation MVRP Vlan Leave message was transmitted received on an interface Recommended Action No action is required this message is for information only VLAN NEW VLAN New for d s on s Severity Info Explanation MVRP Vlan New message was transmitted received on an interface Recommended Action No action is required this message is for information only EOS User Manual 87 CHAPTER 2 SYSTEM MESSAGES 2 53 NAT Messages ACL FILTER INVALID ACTION NAT ACL s configured on interface s has invalid action s Severity Error Explanation The switch is unable to program this NAT rule Recommended Action Reconfigure your ACL to use permit action ACL FILTER INVALID DESTINATION ADDRESS NAT ACL s configured on interface s has invalid destination address match s Severity Error Explanation The switch is unable to program this NAT rule Recommended Action Reconfigure your ACL to remove the destination address match ACL FILTER INVALID PROTOCOL NAT ACL s configured on interface s has proto
14. Failed to identify this system Severity Emergency Explanation A fatal error occurred while attempting to identify this sytem This may be a hardware or software failure Upgrading software to a newer release may be required System functionality will be severely limited Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved SYSTEM IDENTIFICATION FALLBACK Unable to identify system details Falling back to system description programmed into hardware Severity Info Explanation The detailed hardware description is unknown in this software version The description programmed into the hardware is being used Recommended Action No action is required this message is for information only VERIFY AGENT FAILED Verification of forwarding agent failed Severity Error Explanation s Agent will restart Recommended Action No action is required this message is for information only VERIFY _AGENT_RETRY_NEEDED Verification of forwarding agent did not complete Severity Info Explanation s Recommended Action No action is required this message is for information only VRMFAILURE Fatal hardware error of VRM s Severity Emergency Explanation The given VRM can no longer be accessed Functionality of the containing fru may be severely limited Recommended Action This is a critical co
15. Hardware resources are insufficient to program all mpls tunnel entries Severity Error Explanation The switch is unable to program all mpls tunnel entries due to insufficient hardware resources Recommended Action Reconfigure your network to reduce the number of mpls tunnel entries in the switch ROUTING MPLS TUNNEL RESOURCE NORMAL All mpls tunnel entries are programmed in hardware Severity Error Explanation The switch was able to program all the mpls tunnel entries in hardware Recommended Action No action is required this message is for information only EOS User Manual 123 CHAPTER 2 SYSTEM MESSAGES ROUTING_OVERFLOW s is unable to fit all the routes in hardware due to lack of s All routed traffic will be dropped Severity Error Explanation All routed traffic will be dropped due to lack of hardware resources Recommended Action Reconfigure your network ROUTING OVERFLOW RECOVERY COMPLETED s recovered from routing overflow Severity Error Explanation All routes have been re added Recommended Action No action is required this message is for information only ROUTING OVERFLOW RECOVERY STARTED s is starting to recover from routing overflow Severity Error Explanation All routes are being re added Recommended Action Reconfigure your network if routing overflow persists SERDES_RESTORED_TO_FABRIC Serdes s restored to the switch fabric Severity Warning Explanation A fabric serdes has bee
16. No action is required this message is for information only FPV2 PERR TRANSIENT Transient parity error occured in FocalPoint chip s s count d Severity Info Explanation A parity error occurred while forwarding a frame in a FocalPoint switching ASIC The frame will have been dropped or transmitted cut through with a forced bad CRC but the error will have no further effect Recommended Action No action is required this message is for information only FPV2_PERR_WRITEBACK END Finish software correction of ECC protected memory in FocalPoint chip s SRAM d Severity Info Explanation A parity error occurred in one of the SRAM areas in a FocalPoint switching ASIC The affected entry is repaired on reads by ECC logic in the SRAM To correct the hardware a write to the affected entry is necessary Finishing this write Traffic forwarding will not be affected by this Recommended Action No action is required this message is for information only FPV2_PERR_WRITEBACK _ START Start software correction of ECC protected memory in FocalPoint chip s SRAM d Severity Info Explanation A parity error occurred in one of the SRAM areas in a FocalPoint switching ASIC The affected entry is repaired on reads by ECC logic in the SRAM To correct the hardware a write to the affected entry is necessary Beginning this write Traffic forwarding will not be affected by this Recommended Action No action is required this m
17. Severity Info Explanation An SSH tunnel was just started to a remote server Recommended Action No action is required this message is for information only SSH_TUNNEL_HOSTKEY_VERIFY_FAILED SSH tunnel s was unable to connect to the configured host because it could not verify the hostkey of the remote host Severity Error Explanation The switch is set to check all hostkeys of remote entities it connects to Verification of the remote host failed and the switch did not connect Recommended Action Make sure the known hosts for the switch contains the hostkey the remote SSH server is offering upon connection SSH_TUNNEL_HOSTNAME SSH tunnel s was unable to resolve hostname s Severity Error Explanation The SSH tunnel was unable to resolve the hostname and could not connect Recommended Action Check the hostname and DNS resolution EOS User Manual 129 CHAPTER 2 SYSTEM MESSAGES SSH_TUNNEL INITIAL TIMEOUT SSH tunnel s was unable to reach the remote host and the connection timed out Severity Error Explanation SSH Tunnels have a limited amount of time to reach the host to make the connection The tunnel was unable to find a route to the configured host in that timeframe Recommended Action Check that the address for the configured host is correct and that a route exists from the switch to the host SSH_TUNNEL_LOCAL_PORT_ERROR SSH Tunnel s was unable to use the configured local port Severity Error Explanatio
18. Severity Warning Explanation The number of streams received is appropriate for size of ingess stream table Recommended Action No action is required this message is for information only EXPIRED INGRESS STREAM Reachability Monitor detected an expired probe stream s Severity Info Explanation The switch detected a probe stream that has expired because probes were not received for robustness time intervals Recommended Action No action is required this message is for information only EXPIRED INGRESS STREAMS Reachability Monitor detected d expired probe stream s in the last d seconds Severity Info Explanation The switch detected probe stream s that have expired because probes were not received for robustness time intervals Recommended Action No action is required this message is for information only INGRESS STREAM TABLE EXCEEDED Reachability Monitor detected this switch has exceeded the config ured limit of d streams recorded in the ingress stream table Severity Warning Explanation Too many streams have been received by the switch Recommended Action Please increase the size of the ingress stream table or reduce the number of streams being sent to this switch by other beacons in the network EOS User Manual 109 CHAPTER 2 SYSTEM MESSAGES INGRESS STREAM _TABLE_OK Reachability Monitor detected this switch no longer exceeds the configured limit for the number of streams recorded in the ingr
19. The switch is unable to program all IgmpSnooping groups because the IgmpSnooping groups exceed the available hardware resources Recommended Action To solve this issue reconfigure the network to reduce the number of IgmpSnooping groups When the number of groups reduces the switch automatically programs any unprogrammed groups in hardware HW_RESOURCE_NORMAL All multicast routes are programmed in hardware Severity Error Explanation The switch was able to program all the IgmpSnooping groups in hardware and normal hardware routing has resumed Recommended Action No action is required this message is for information only NOT_EXPECT_ROUTER Router detected in VLAN d Severity Warning Explanation The switch report flooding feature is designed for pure L2 environment Recommended Action Please correct network configuration NO_IGMP_QUERIER No IGMP querier detected in VLAN d IGMP report received from d on d for d Severity Info Explanation The switch did not detect an IGMP querier running in the specified VLAN This will cause multicast traffic to be flooded to all members of the VLAN Recommended Action Configure an IGMP querier for the specified VLAN QUERY VERSION CONFIGURED DISCREPANCY IGMP version d query heard on vlan d by a querier configured to version d Severity Warning Explanation The switch detected an IGMP query message of a different version than the version that is currently configured Recommende
20. 1 Reduce the number of ACLs 2 Use fewer StormController settings EOS User Manual 20 CHAPTER 2 SYSTEM MESSAGES 2 14 DOT1X Messages ACCT FALLBACK Accounting method s is currently unavailable falling back to next method Severity Warning Explanation The accounting method failed to provide an answer and is considered unavailable If the method list for this service contains a fallback method this request will be retried via that method Recommended Action Check the availability and reachability of the accounting server s ACCT_MSG DROP No available server accounting message has been dropped Severity Warning Explanation None of the accounting servers are responsive and the switch has dropped the message Recommended Action Check the availability and reachability of the accounting server s AUTHN FALLBACK Authentication method s is currently unavailable falling back to next method Severity Warning Explanation The authentication method failed to provide an answer and is considered unavailable If the method list for this service contains a fallback method this request will be retried via that method Recommended Action Check the availability and reachability of the authentication server s DUPLICATE_SUPPLICANT Supplicant with MAC s authenticated on port s attempted to communicate using the 802 1X protocol on another port s Severity Error Explanation An authenticated supplicant appeared
21. CLI command taking long to complete Please try to increase execution interval to a larger value COMMAND_REQUEST ERROR Error s on command execution Severity Warning Explanation Unexpected error caught during the execution of the command Recommended Action No action is required this message is for information only CONFIG E Enter configuration mode from s by s on s s Severity Notice Explanation A network administrator has entered global config mode or updated the system configuration from a configuration file Recommended Action No action is required this message is for information only CONFIG 1 Configured from s by s on s s Severity Notice Explanation A network administrator has exited global config mode or updated the system configuration from a configuration file Recommended Action No action is required this message is for information only CONFIG_REPLACE FAILURE Configuration replace operation by s with s failed on s s Severity Error Explanation A network administrator has attempted to replace the running configuration of the system but the operation failed The running configuration of the system has not changed Recommended Action No action is required this message is for information only EOS User Manual 144 CHAPTER 2 SYSTEM MESSAGES CONFIG_REPLACE_SUCCESS User s replaced running configuration with s successfully on s s Severity Notice Explanation
22. EOS User Manual TI CHAPTER 2 SYSTEM MESSAGES 2 46 MLAG Messages INTF_ACTIVE Local interface s and peer interface s are link up MLAG s is active Severity Info Explanation Both local and peer interfaces assigned to an MLAG are link up Recommended Action No action is required this message is for information only INTF_ESTABLISHED Interface s is in MLAG s with peer interface s Severity Info Explanation Both peers added an enabled local interface to the same MLAG Recommended Action No action is required this message is for information only INTF INACTIVE LOCAL Local interface s is link down MLAG s is inactive Severity Warning Explanation The local interface that is assigned to an MLAG is link down The peer must handle all of the traffic on that link until the MLAG is active Recommended Action Ensure that the local interface comes up INTF INACTIVE PEER Interface s is link down on the MLAG peer MLAG s is inactive Severity Warning Explanation The peer interface that is assigned to an MLAG is down This chassis must handle all of the traffic on the link until the MLAG is active Recommended Action Ensure that the peer interface comes up INTF_INACTIVE PEER _LINK_DOWN The MLAG peer is down MLAG s became inactive Severity Warning Explanation This chassis must handle all of the traffic on the link until the MLAG peer is up Recommended Action Ensure that the MLAG peer resumes operatio
23. Explanation The remote server did not support an algorithm that the switch could use Recommended Action Check if the server and switch are configured correctly SSH_TUNNEL_CLOSED REMOTELY SSH tunnel s had it s connection closed by the remote host Severity Error Explanation The SSH Tunnels connection was closed by the remote host Recommended Action Check the logs for the remote hosts SSH server SSH_TUNNEL_CONFIGURED SSH tunnel s from local TCP port s to s s via s s is fully configured Severity Info Explanation An SSH tunnel was just configured and will try to connect Recommended Action No action is required this message is for information only SSH_TUNNEL_CONNECTION_REFUSED SSH tunnel s had its initial connection refused by the remote host Severity Error Explanation The initial attempt to open an ssh connection was refused by the remote host Recommended Action Check that the remote host has its ssh server running and accepting connections on port 22 SSH_TUNNEL_CORRUPT PACKET RECEIVED SSH tunnel s received a corrupt packet from the configured remote server Severity Error Explanation A packet from the remote server was received that passed the TCP IP checksum but failed the SSH checks Recommended Action If the problem persists contact your support representative Otherwise no action is required SSH_TUNNEL_ESTABLISHED SSH tunnel s from local TCP port s to s s via s s is established
24. Info Explanation This may be caused by other switches on the network using ether type 0x88B7 but the source mac for the packet matched this switch Recommended Action No action is required this message is for information only THROTTLE Too many loop protection packet transmits in a second Throttling Severity Warning Explanation Loop protection is configured to rate limit the number of packets sent per second and this limit was reached Recommended Action No action is required this message is for information only EOS User Manual 72 CHAPTER 2 SYSTEM MESSAGES 2 41 LSPPING Messages SERVER ERROR s Severity Error Explanation Lsp Ping server hit an error during operation Recommended Action No action is required this message is for information only EOS User Manual 73 CHAPTER 2 SYSTEM MESSAGES 2 42 MAPREDUCEMONITOR Messages TASKTRACKER ACTIVE TaskTracker s changed state to active Severity Info Explanation TaskTracker resolved as locally attached by the switch Recommended Action No action is required this message is for information only TASKTRACKER INACTIVE TaskTracker s changed state to inactive due to s Severity Info Explanation TaskTracker cannot be determined to be locally attached either due to unresolved ARP entry from TaskTracker IP address or failure to resolve the TaskTracker name to an IP address The log message provides the cause Recommended Action Check the c
25. RUNNING Master ProcMer PID d monitoring ProcMgr worker PID d Severity Info Explanation The master ProcMgr is monitoring the ProcMgr worker process Recommended Action No action is required this message is for information only MASTER STARTED Master ProcMgr process started PID d Severity Info Explanation The ProcMgr master process has started running Recommended Action No action is required this message is for information only EOS User Manual 97 CHAPTER 2 SYSTEM MESSAGES NEW PROCESSES New processes configured to run under ProcMgr control s Severity Debug Explanation The specified processes have been added to the set of processes that run under ProcMgr control This message is informational only Recommended Action No action is required this message is for information only PROCCFG BADVALUE Error bad config value for process s s s Severity Error Explanation The config file for the process specified a valid config option but set that option to an invalid value The process will not be started Recommended Action If the problem persists contact your support representative Otherwise no action is required PROCCFG INCOMPLETE Error Process incompletely configured exe s argv s heartbeatPeriod s Severity Error Explanation One or more of the required process config parameters was not set Recommended Action Confirm that the package containing the
26. SYSTEM MESSAGES 2 22 FRU Messages CARD_FAILURE Hardware failure when reading the card in slot s Severity Error Explanation A fatal error occurred when attempting to access a card Recommended Action This is a software or hardware problem It may be necessary to upgrade software or replace the card CARD_INSERTED Card s has been inserted model s rev s serial number s Severity Info Explanation Card insertion detected Recommended Action No action is required this message is for information only CARD_INTERFACE CONFIG REMOVED Interface configuration on s removed due to incompatible card model for configuration current model s previous model s Severity Info Explanation Card interface configuration removed Recommended Action No action is required this message is for information only CARD_REMOVED Card s has been removed model s rev s serial number s Severity Info Explanation Card removal detected Recommended Action No action is required this message is for information only CARD_SUBOPTIMAL_COOLING Card s is located in a suboptimal slot for chassis cooling It is optimized for slots s Severity Error Explanation The inserted card is located in a suboptimal slot for chassis cooling Recommended Action Verify that the card is inserted into an optimal slot for chassis cooling Please contact support for information on optimal card configurations CARD_UNSUPPORTED Card in sl
27. Severity Emergency Explanation The system could not perform an upgrade of a Chl822X device This may be due to a hardware or software failure Recommended Action Rebooting the system may solve the problem This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved DISRUPTIVE_RESTART Non disruptive restart of s forwarding agent failed All hardware entries in s table will be deleted and re programmed in the hardware Severity Error Explanation Forwarding agent could not recover its hardware state during restart This could result in hardware state being deleted and re programmed in the hardware This can result in traffic disruption Recommended Action No action is required this message is for information only EOS User Manual 46 CHAPTER 2 SYSTEM MESSAGES ERROR DETECTED Software has detected s s Severity Error Explanation Software has detected a problem Recommended Action If the problem persists contact your support representative Otherwise no action is required EXCESSIVE_MULTIPLE_BIT_ERRORS Excessive multibit memory errors detected in chip s Severity Error Explanation An excessive number of multibit memory errors detected in a switchingASIC Please contact support Recommended Action This is a serious error Contact your customer support representative with the contents of the
28. Severity Error Explanation The ProcMgr worker process terminated unexpectedly and is being restarted immediately Recommended Action Keep an eye on this message if it happens frequently something is wrong with the system EOS User Manual 100 CHAPTER 2 SYSTEM MESSAGES WORKER_WARMSTART ProcMgr worker warm start PID d Severity Info Explanation ProcMgr is doing a warm start re reading all config files starting stopping adopting procs as needed Recommended Action No action is required this message is for information only WORKER_WARMSTART_DONE ProcMgr worker warm start done PID d Severity Debug Explanation ProcMgr has finished its warm start Recommended Action No action is required this message is for information only EOS User Manual 101 CHAPTER 2 SYSTEM MESSAGES 2 63 PTP Messages GRANDMASTER CHANGE Old Grandmaster s New Grandmaster s Severity Warning Explanation A change in the grandmaster clock in the PTP domain Recommended Action No action required HARDWARE SYNC MASTER CLOCK ERROR Possible hardware error with the PTP HardwareSync master clock Severity Error Explanation The master clock provider is producing a frequency other than expected Recommended Action If the problem persists contact your support representative Otherwise no action is required HARDWARE SYNC SLAVE CRC ERROR PTP TimeSync CRC error detected on switch chip s Severity Error Explanation
29. The aforementioned switch chip received a TimeSync message with a CRC error Recommended Action If the problem persists contact your support representative Otherwise no action is required HARDWARE SYNC SLAVE HW ERROR Possible TimeSync counter frequency error for switch chip s Severity Error Explanation The switch chips interal TimeSync counter is counting at a frequency that is past the acceptable tolerance Recommended Action If the problem persists contact your support representative Otherwise no action is required HARDWARE_SYNC_SLAVE TOO_LONG_TO_SYNC Switch chip s is taking too long to synchronize with TimeSync master Severity Error Explanation The aforementioned switch chip has not synchronized with the TimeSync master for a long time Recommended Action If the problem persists contact your support representative Otherwise no action is required NOT_SUPPORTED_VERSION PTP V1 packet has been received on interface s Severity Warning Explanation An unsupported 1588 PTP V1 packet has been received on interface s Recommended Action You can configure ptp forward vl cli command for incoming PTP V1 packets to pass through the switch as normal multicast traffic PEER DOWN Interface s is no longer AS Capable Severity Warning Explanation A gPTP capable peer is no longer present on this link Recommended Action No action required PEER UP Interface s is AS Capable Severity Info Explanation A gP
30. Warning Explanation Sand agent is exiting and will restart Recommended Action If the problem persists contact your support representative Otherwise no action is required CARD INIT FAILED Initialization of s failed because of a software error Severity Error Explanation In some rare cases a linecard or fabric card cannot be initialized after a switchover because of a software condition Recommended Action Turn off and then turn on the power for the card that has failed to initialize COUNTER_DMA ERROR Counter DMA error d on channel d occurred for s Severity Error Explanation An error has happened while reading queue counters This may result in lost queue counter updates Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved DDR_BIST_FAILED Switch ASIC d dram d failed dram bist Severity Error Explanation The Arad switch ASIC failed dram bist test Please contact support Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved DDR_NO_INFO Switch ASIC d DDR memory bank settings not available Severity Error Explanation The switch ASIC d cannot be initialized without information about DDR memory banks Recommended Action T
31. action is required ISSHD RESTART SUCCEEDED isshd service has restarted on Supervisor d standby Severity Notice Explanation The internal sshd service that runs on standby supervisor has stopped unexpectedly The service monitoring agent has restarted it Recommended Action If the problem persists contact your support representative Otherwise no action is required ISSHD_STOP_ FAILED stopping isshd service failed on Supervisor d active Severity Error Explanation The internal sshd service should not run on active supervisor The service monitoring agent failed to stop it Recommended Action If the problem persists contact your support representative Otherwise no action is required IS_ACTIVE Supervisor became active Severity Notice Explanation This supervisor has become active Now it will take over the management interface and control the linecards and fabric cards Recommended Action No action is required this message is for information only IS_DISABLED Supervisor became disabled Severity Critical Explanation This supervisor has been disabled which means that it will not become active even if the active supervisor fails Now the switch is running with one supervisor less Recommended Action If you did not deliberately disable the supervisor contact your support IS_STANDBY Supervisor became standby Severity Notice Explanation This supervisor has become standby Now it is ready to become ac
32. any errors If the problem persists contact your support representative Otherwise no action is required EXEC_SCRIPT_SUCCESS Successfully executed the downloaded config script Severity Notice Explanation Zero Touch Provisioning successfully executed the downloaded config script Recommended Action No action is required this message is for information only EXEC_SCRIPT_TIMEOUT Timed out executing the downloaded config script after u seconds Severity Warning Explanation Zero Touch Provisioning timed out after waiting long enough for the downloaded config script to complete execution This usually indicates a problem with the config script Recommended Action Check the config script for any errors If the problem persists contact your support representative Otherwise no action is required INIT No startup config found starting Zero Touch Provisioning Severity Notice Explanation No startup config was found on flash the system has entered Zero Touch Provisioning mode and is actively trying to download the startup config from a remote system To cancel Zero Touch Provisioning type zerotouch cancel at the CLI Recommended Action No action is required this message is for information only INTERFACE SPEED Setting interface speed to s for s Severity Notice Explanation Set the global speed on all capable interfaces Recommended Action No action is required this message is for information only RELOAD Reb
33. are insufficient to add vxlan multicast group Severity Error Explanation The switch is unable to program multicast group for vxlan due to insufficient hardware resources Flood traffic may not be sent to all the ports in vlan Recommended Action Reconfigure your network to reduce the number of multicast groups in the switch VXLAN_NEXTHOP_RESOURCE_FULL Hardware resources are insufficient to add vxlan port s for vlan d Severity Error Explanation The switch is unable to program nexthop for the vxlan port due to insufficient hardware resources Traffic forwarding will not happen on this port Recommended Action Reconfigure your network to reduce the number of nexthop entries in theswitch EOS User Manual 142 CHAPTER 2 SYSTEM MESSAGES VXLAN_PORT_TO_NEXTHOP_OVERLAP Vxlan module d port d to nexthop d table overlap s Severity Info Explanation Vxlan tunnels resolved through same physical port do not share first hop router Some of the tunnels may not be reachable Recommended Action Reconfigure your network so that tunnels resolved through same physical port share the same first hop router VXLAN RECIRC_CHANNEL_ NOT CONFIGURED Recirc channel has not been configured for use with Vxlan routing Severity Error Explanation A Recirc channel interface with vxlan features is required for proper functioning of flows involving routing and Vxlan encap decap Recommended Action Configure a Recirc channel and enable
34. be programmed EOS User Manual 30 CHAPTER 2 SYSTEM MESSAGES VLAN FLOODSET FORWARDING RESUMED Traffic sent to the vlan floodset will be forwarded normally in vlan d Severity Error Explanation Broadcast and unknown DA traffic sent to the vlan floodset will be forwarded normally in this VLAN Recommended Action No action is required this message is for information only VLAN MAPPING TABLE FULL Unable to map VLAN d to d for interface s on s due to hardware resource exhaustion Severity Warning Explanation The specified VLAN mapping could not be programmed due to insufficient hardware resources Packets on the original VLAN will no longer be mapped Recommended Action To solve this issue please reduce the number of vlan mappings that are currently configured and try again VNIVLANMAPFULL Unable to program VLAN d to VNI d mapping due to hardware resource exhaustion Severity Warning Explanation The specified mapping could not be programmed into the switching ASIC Remote VXLAN packets destined for the specified VNI from the specified VLAN will not be forwarded Recommended Action Reduce the number of such mappings that need to be programmed into the switching ASIC Please contact your technical support representative if you need additional assistance EOS User Manual 31 CHAPTER 2 SYSTEM MESSAGES 2 17 EVENTMON Messages DB_WRITE FAILED A sqlite s exception occurred when writing to the EventMon database
35. by the BPDU rate limiter configured for that port or the global rate limiter In order to prevent a suspected denial of service attack the switch has disabled the port Figure out why the number of BPDUs received on the port exceeds the expected maximum and re enable the port DISABLED Spanning tree is disabled Severity Info Explanation The spanning tree protocol is disabled All ports are forwarding Recommended Action No action is required this message is for information only INTERFACE_ADD Interface s has been added to instance s Severity Info Explanation The given interface is now running the given spanning tree instance Recommended Action No action is required this message is for information only INTERFACE BRIDGE ASSURANCE ENTER Interface s in s is entering the bridge assurance inconsistent state Severity Warning Explanation The given interface is configured as a network port with bridge assurance Thus it should be connected to another bridge running bridge assurance at all times However the interface has not been receiving BPDUs so it has been set to inconsistent to avoid STP loops Recommended Action The port will exit the inconsistent state if it begins receiving BPDUs again bridge assurance is disabled or the port is reconfigured as a non network port INTERFACE _BRIDGE_ASSURANCE_EXIT Interface s in s is exiting the bridge assurance inconsistent state Severity Warning Explanation The give
36. bytes Severity Warning Explanation A BGP notification message of length bytes was seen from to the given neighbor with code subcode string names s s Such messages notify a peer either about errors in the BGP session or in the case of CEASE ErrorCode 6 request the session to terminate If an Error notification is received this message means a neighbor believes this machine sent an invalid BGP message If sent this message means this machine believes that a neighbor sent an invalid BGP message Either the message was malformed or it arrived at a time when it was not expected Recommended Action Some messages such as cease require no action Error messages such as Message Header Error can be symptomatic of some other BGP error The data printed in the BGP NOTIFICATION log entry may help a technical support person determine the underlying error PEER_CLEAR BGP peering with s was reset by s on s s Severity Notice Explanation BGP peering was reset by CLI command Recommended Action No action is required this message is for information only EOS User Manual 13 CHAPTER 2 SYSTEM MESSAGES 2 8 BIDIR Messages RPA_RESOURCE FULL RPA used in Pim bidirectional has exceeded the limit Severity Error Explanation Please make sure the number of RP used for Pim Bidirectional from BSR and static RP configuration are not exceeding the limit Recommended Action This is a serious error Contact your customer sup
37. cache Recommended Action No action is required this message is for information only SETUP_ERROR Error s occurred while trying to set up socket to listen for connections from MSDP peers Severity Warning Explanation A socket error occured while attempting to start listening for MSDP peers The Msdp agent will restart in order to recover from this error Recommended Action If the problem persists contact your support representative Otherwise no action is required UNKNOWN _PACKET_TYPE An unknown MSDP packet type d received and discarded Severity Warning Explanation A MSDP packet type that is not handled by the implementation was received Recommended Action No action is required this message is for information only EOS User Manual 84 CHAPTER 2 SYSTEM MESSAGES 2 51 MSRP Messages BW_ALLOC FAIL Bandwidth d kbps allocation failed for listener on s and streamId 0x s Severity Info Explanation MSRP Bandwidth could not be allocated for a listener Recommended Action No action is required this message is for information only BW_ALLOC SUCCESS Bandwidth d kbps successfully allocated for listener on s and streamld 0x s Severity Info Explanation MSRP Bandwidth was allocated for a listener Recommended Action No action is required this message is for information only BW _DEALLOC Bandwidth d kbps deallocated for listener on s and streamld 0x s Severity Info Explanation MSRP Bandw
38. information only BOUNDARY ACL_DISCONTIG MASK Pim Boundary ACL s uses unsupported discontiguous mask s Severity Warning Explanation The switch is unable to enforce this boundary rule It will be ignored Recommended Action Reconfigure the ACL to use contiguous masks BOUNDARY ACL INVALID MCAST_ ADDR Pim Boundary ACL s uses non multicast address s Severity Warning Explanation The switch is unable to enforce this boundary rule It will be ignored Recommended Action Reconfigure the ACL to use multicast addresses MESSAGE INVALID DESTINATION Invalid PIM destination s for PIM type d received from source s Severity Error Explanation The IP destination sent by the peer PIM router is not correct Recommended Action Capture the packet using tcpdump and contact support MESSAGE INVALID TYPE Invalid PIM type d received from source s Severity Error Explanation The PIM type is not recognized Recommended Action Capture the packet using tcpdump and contact support MESSAGE INVALID_VERSION Invalid PIM version d received from source s Severity Error Explanation The version sent by the peer PIM router is not supported Recommended Action Capture the packet using tcpdump and contact support MESSAGE _UNPROCESSQ FULL PIM unprocessed message queue is full for neighbor s message type d Severity Notice Explanation Delayed protocol convergence is expected Recommended Action No action is required this
39. initialization of switch ASICs failed and the switch is being rebooted to recover from the failure If initialization fails a second time no automatic reboot will occur Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 121 CHAPTER 2 SYSTEM MESSAGES REQUEST_RESET Request reset of s Severity Warning Explanation Specified reset was requested by CLI command Recommended Action No action is required this message is for information only RESET EGRESS SCHEDULER Reset egress scheduler of switch chip s Severity Warning Explanation Software has reset the egress scheduler of the switch chip Recommended Action No action is required this message is for information only RESET_FULL_CHIP Reset all internal blocks of switch chip s Severity Warning Explanation Software re initialized all internal blocks of the switch chip This reset causes some traffic loss but does not flap the links Recommended Action No action is required this message is for information only ROUTING ARP RESOURCE FULL Hardware resources are insufficient to program all ARP entries Severity Error Explanation The switch is unable to program all ARP entries due to insufficient hardware resources Recommended Action Reconfigure your network to reduce the number of ARP entries in the switch ROUTING ARP RESOURCE NORMAL All ARP entries are programmed in hardw
40. message and plan to be unable to use the system until the problem has been solved FANCONTROLLER COMMUNICATION ERROR Communication error with the fan controller s Severity Error Explanation An error occurred while giving commands over SMBus to a fan controller Recommended Action If the problem persists contact your support representative Otherwise no action is required FANSMBUSFAILURE Error detected in the System Management Bus connection to fan slot s Severity Error Explanation Software detected an error in the System Management Bus connection to the given fan Fan detection has been disabled for this slot Recommended Action Try replacing the affected fan again If the problem persists please contact your support representative for assistance FPGA ERROR Hardware error occurred on a FPGA on the card s Reason s Power cycle the card at your earliest convenience to clear the error Severity Error Explanation Software detected a hardware error on the named card FPGA Recommended Action If the problem persists contact your support representative Otherwise no action is required FPGA ERROR DEBUG Software has read debugging information for the hardware error on FPGA s on card s Partition s frame address s word address s bit address s FRAME_CRC_STATO s FRAME_CRC_STATI s Severity Info Explanation Software has read debugging information for the hardware FPGA error Recommended Action If the
41. message is for information only MODE MISMATCH Neighbor s is running s while interface s is running s Severity Error Explanation The PIM neighbor state cannot be formed due to mismatch in mode Recommended Action No action is required this message is for information only NBRCHG neighbor s s on interface s Severity Notice Explanation The PIM neighbor state changed on the interface Recommended Action No action is required this message is for information only NEIGHBOR SECONDARY ADDRESS CONFLICT Neighbor s advertised secondary address s on interface s which was previously advertised by neighbor s Severity Notice Explanation There is a conflict and the same secondary address was previously advertised by another neighbor The most recently received mapping is maintained Recommended Action No action is required this message is for information only EOS User Manual 93 CHAPTER 2 SYSTEM MESSAGES 2 59 PIMBSR Messages CRPADV_ZONE SET Received Candidate RP Advertisements from C RP s with Zone bit set Severity Info Explanation This is an unusual condition for which RFC 5059 mentions BSR mechanism to log such activities This log is only for informational purpose and is produced when a multicast boundary router is configured as a Candidate RP This does not pose any operational issue Recommended Action In order to not see this message remove Candidate RP configuration from the multicast boun
42. of the interface DYNA_VLANVNI INVALID CONFIG INTERNAL Dynamic VLAN to VNI mapping from s has been ignored VLAN d has already been allocated internally Severity Warning Explanation A dynamic VLAN to VNI mapping has been ignored because the specified VLAN has already been internally reserved by a routed port Recommended Action Change the VLAN configured in the mapping DYNA_VLANVNI INVALID CONFIG PEERLINK Dynamic VLAN to VNI mapping from s has been ignored VLAN d has already been allocated to the MLAG peer link SVI Severity Warning Explanation A dynamic VLAN to VNI mapping has been ignored because the specified VLAN has already been allocated to the MLAG peer link SVI Recommended Action Change the VLAN configured in the mapping DYNA_VLANVNI INVALID PORT NAME Dynamic VLAN to VNI mapping from s has been ignored unknown interface name s Severity Warning Explanation A dynamic VLAN to VNI mapping has been ignored because the interface name is invalid Recommended Action Verify the dynamic VLAN to VNI mapping from the source EOS User Manual 161 CHAPTER 2 SYSTEM MESSAGES HW_FLOOD_RESOURCE FAILED Internal failure d detected while programming vxlan multicast tunnels s Severity Error Explanation The switch is unable to program all multicast tunnels due to internal failure When the switch is unable to program multicast tunnels due to internal failure it may drop certain packets in order to avoid potenti
43. or Mlag peerMac configuration INCOMPATIBLE_WITH_VARP Ignoring VRRP MAC address s in s because VARP is configured Severity Error Explanation VRRP and VARP cannot be configured at the same time Recommended Action Remove either the VRRP or VARP configuration STATECHANGE s Grp d state s s Severity Notice Explanation The VRRP router has changed state Recommended Action No action is required this message is for information only UNPROGRAMMED ADDRESS NO LONGER CONFIGURED No longer need to program VRRP MAC address s in s that was previously unable to fit into hardware Severity Error Explanation No longer need to program VRRP MAC address that was previously unable to fit into hardware Recommended Action No action is required this message is for information only EOS User Manual 160 CHAPTER 2 SYSTEM MESSAGES 2 93 VXLAN Messages DYNA _VLANVNI CONFLICT CLI VLAN Dynamic VLAN to VNI mapping d to d from s on VTI s has been ignored because VLAN d has explicitly been mapped to a different VNI d Severity Info Explanation A dynamic VLAN to VNI mapping has been ignored because the specified VLAN has been mapped to a different VNI through a CLI configuration Recommended Action Verify the dynamic VLAN to VNI mapping source or change the configured VLAN to VNI mapping If you are deliberately overriding the dynamic configuration no action is required DYNA_VLANVNI_CONFLICT_CLI_VNI Dynamic
44. parameters has failed Existing diffie hellman parameters will be used Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 16 CHAPTER 2 SYSTEM MESSAGES 2 11 CARD Messages NOT_COMPATIBLE s s is not supported because s Severity Error Explanation In the current configuration this card is incompatible Recommended Action Change configuration using platform sand fabric forwarding mode mode save configuration and reboot the system EOS User Manual 17 CHAPTER 2 SYSTEM MESSAGES 2 12 CLEAR Messages COUNTERS Clear scounters sby s on s s Severity Notice Explanation Counter was cleared by CLI command Recommended Action No action is required this message is for information only EOS User Manual 18 CHAPTER 2 SYSTEM MESSAGES 2 13 DATAPLANE Messages COUNTER RESOURCE CONFLICT counter resource conflict between s and s Severity Warning Explanation s and s are mutually exclusive only one of them can be enabled Recommended Action use counter feature command to enable only one of the features COUNTER RESOURCE FULL Hardware resources are insufficient to enable counter for feature s Severity Warning Explanation The switch is unable to program counter features s due to insufficient hardware resources Recommended Action Use counter feature command to disable some features CUT_THROUGH DISABLE
45. resetting the fabric This may be a symptom of a possible problem with a fabric card Recommended Action If the problem persists contact your support representative Otherwise no action is required POSSIBLE STUCK PORT s may be stuck Tx queues should be empty but descriptors detected UC d MC d chip d Severity Error Explanation There are packet descriptors in a disabled port s tx queues This can be a symptom of a stuck egress port If you enable the port and no packets transmit out the port is unusable until the forwarding agent restarts Recommended Action If the problem persists contact your support representative Otherwise no action is required POWER_CYCLE_AFTER INIT_FAILURE s is being power cycled due to consecutive initialization failures Severity Error Explanation The initialization of switch asics failed and the card is being power cycled to recover from the failure Recommended Action If the problem persists contact your support representative Otherwise no action is required POWER_CYCLE_REQUIRED Software detected an error condition which requires a power cycle to recover Please reload the system at the soonest convenient time Severity Error Explanation Software detected that a power cycle is required but is unable to power cycle the hardware Please reload the system to power cycle it and recover from the error Recommended Action If the problem persists contact your support representative Othe
46. the CLI or Pim will be discarded in this VLAN because hardware resources are full Recommended Action Use fewer VLANs with unknown multicast traffic UNKNOWN MULTICAST_FORWARDING_RESUMED Multicast sent to a group with no local members will be flooded normally in VLAN d Severity Warning Explanation Multicast packets for groups that have not been learned by IGMP Snooping nor programmed via the CLI or Pim will be flooded normally to the entire VLAN or router interfaces as expected Recommended Action No action is required this message is for information only VLAN_ENCAP_TABLE_FULL Unable to encapsulate s packets on interface s with VLAN d due to hardware resource exhaustion Severity Warning Explanation The encapsulation could not be programmed due to insufficient hardware resources Packets on the specified interface will no longer be encapsulated Recommended Action To solve this issue please reduce the number of vlan mappings that are currently configured and try again VLAN _FLOODSET_ FORWARDING DISABLED Traffic sent to the vlan floodset in vlan d will be discarded s Severity Error Explanation Broadcast and unknown DA traffic sent to the vlan floodset will be discarded in this VLAN The vlan floodset could not be programmed because hardware resources are full Recommended Action Remove multicast groups or vlans in order to reduce hardware usage When hardware resources are freed the vlan floodset will automatically
47. the SA cache a received SA was rejected i e not stored in the cache Recommended Action Deconfiguring a peer will cause that peer s SAs to age out of the cache making room for more SAs NO_RPF_PEER MSDP RPF Peer for Pim RP a does not exist Severity Warning Explanation MSDP is unable to find a RPF Peer for the Pim RP using MSDP RFC s rules Recommended Action If the problem persists contact your support representative Otherwise no action is required PEER_CONNECTED MSDP connection with peer a is up Severity Info Explanation MSDP peering with the peer is successful the peers will now exchange multicast sources Recommended Action No action is required this message is for information only PEER DISCONNECTED MSDP connection with peer a is down Severity Info Explanation MSDP peering with the peer is unsuccessful the peers will not exchange multicast sources Recommended Action No action is required this message is for information only PEER SETUP_ERROR s while trying to set up MSDP connection with peer a Severity Warning Explanation A socket error occured while attempting to connect with this peer Recommended Action If the problem persists contact your support representative Otherwise no action is required SA LIMIT SA from peer a RP a for a a exceeded sa limit of d Severity Warning Explanation Due to sa limit configuration a received SA was rejected i e not stored in the SA
48. the problem persists following an upgrade POWERSUPPLY FAILURE Power Supply in slot d failed Severity Error Explanation The power supply inserted in the above slot could not be identified due to hardware errors Recommended Action Check that the power supply is properly inserted It may be necessary to replace the power supply POWERSUPPLY INSERTED Power Supply in slot d has been inserted Severity Info Explanation Power supply insertion detected Recommended Action No action is required this message is for information only POWERSUPPLY_REMOVED Power Supply in slot d has been removed Severity Info Explanation Power supply removal detected Recommended Action No action is required this message is for information only POWERSUPPLY_UNSUPPORTED Power Supply in slot d is not supported Severity Error Explanation The power supply inserted in the above slot is unknown and not supported by the software Recommended Action Replace the power supply with a power supply supported by the version of your software EOS User Manual 40 CHAPTER 2 SYSTEM MESSAGES SEEPROM_CORRUPTED A corrupted Seeprom was detected on device s Repair was s Severity Error Explanation Seeproms can very rarely be corrupted Redundant state covers this issue and often allows for full reparation No action needs to be taken Recommended Action Seeproms contain configurative informatin for the system hardware While a corruption is
49. unable to program new nexthop group entries due to insufficient TTL index hardware resources Recommended Action Configure your network to have new nexthop group entries reuse existing nexthop group TTL values configured in the switch EOS User Manual 122 CHAPTER 2 SYSTEM MESSAGES ROUTING_GRE_TUNNEL_TTL_RESOURCE_NORMAL New nexthop groups with new TTL values maybe programmed now in hardware Severity Warning Explanation The switch maybe able to program new nexthop group entries in hardware as TTL index resource is now available Recommended Action No action is required this message is for information only ROUTING IPV6 HOST ROUTE RESOURCE FULL TCAM entry could not be allocated for IPv6 host route Severity Error Explanation The switch is unable to program IPv6 host routes due to insufficient hardware resources for new IPv6 networks Recommended Action Check the number of IPv6 networks with host routes and restrict unique 64 networks to 511 ROUTING _IPV6_HOST_TCAM_ALLOCATED TCAM bank successfully allocated for IPv6 host routes Severity Error Explanation TCAM bank is now available for programming IPv6 host routes in hardware Recommended Action No action is required this message is for information only ROUTING _IPV6_HOST_TCAM_ALLOC_FAILED TCAM bank could not be allocated for IPv6 host routes Severity Error Explanation The switch is unable to program ipv6 host routes due to insufficient hardware resources Rec
50. unable to use the system until the problem has been solved PLXNIC_NON FATAL ERROR A PCle non fatal error occurred on the NIC port link between the supervisors Severity Error Explanation PCIe NIC port link between the supervisors reported a PCIe uncorrectable non fatal error Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved POWERCONTROLLER BAD OUTPUT _VOLTAGE The power controller on s detected a bad output voltage of f on rail s Rail u Severity Error Explanation Software detected that the power controller is not supplying the correct voltage on one or more of its rails Recommended Action If the problem persists contact your support representative Otherwise no action is required POWERCONTROLLER_BAD STATUS The s power controller reports a status that indicates an error status is x Severity Warning Explanation Software detected that the there is a power controller problem By itself this message does not indicate a problem but will help diagnose a more serious power controller issue Recommended Action If the problem persists contact your support representative Otherwise no action is required POWERCONTROLLER_COMMUNICATION ERROR Communication error with the power controller on s s Severity Error Explanation An error occurred while giving commands over SMB
51. vxlan features on it VXLAN_ROUTING RESOURCE_FULL Unable to program router MAC address s in VLAN d due to hardware resource exhaustion Vxlan routing may not work as expected in this VLAN Severity Warning Explanation The specified MAC address could not be programmed into the switching ASIC due to hardware resource exhaustion This MAC address is pointing to an internal recirculation port and is used for Vxlan routing Hence Vxlan routing may not work as expected while the system is in this state Recommended Action No action is required this message is for information only VXLAN ROUTING RESOURCE NORMAL Router MAC address s in VLAN d was successfully pro grammed in hardware Severity Warning Explanation The specified MAC address was successfully programmed into the switching ASIC Normal vxlan routing should resume in this VLAN Recommended Action No action is required this message is for information only WATCHDOG _POWERCYCLE Power cycling s due to watchdog timeout Severity Error Explanation A card power cycle is used to attempt recovery of a non responsive switch Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 143 CHAPTER 2 SYSTEM MESSAGES 2 81 SYS Messages CLI HOSTNAME INVALID Configured hostname s is invalid Severity Error Explanation The configured hostname is invalid and has been ignored The hostn
52. your support representative Otherwise no action is required SETLINKMODEFAIL Failed to set speed duplex on interface s to s s s Severity Warning Explanation An attempt to set the interface s speed duplex mode failed Recommended Action If the problem persists contact your support representative Otherwise no action is required SETMTUFAIL Failed to set interface s mtu Severity Warning Explanation An attempt to set the interface mtu failed for an unknown reason Recommended Action If the problem persists contact your support representative Otherwise no action is required SETPAUSEPARAMEAIL Failed to set pause parameters on interface s s Severity Warning Explanation An attempt to set the interface s pause parameters failed Recommended Action If the problem persists contact your support representative Otherwise no action is required STORMCONTROL_DISCARDS Storm Control discarded packets on Interface s Broadcast L Multicast L All L Severity Info Explanation The interface s traffic is exceeding the configured storm control threshold causing packets to be discarded Recommended Action No action is required this message is for information only UNKNOWN MULTICAST FORWARDING DISABLED Multicast sent to a group with no local members will be discarded in VLAN d s Severity Warning Explanation Multicast packets for groups that have not been learned by IGMP Snooping nor programmed via
53. 2 isa eA ee A Oh le ee a we a BS 139 2 81 cr MESSAGES ec a Me Ee eal a Dea Ye eK Gee SO ea ewes 144 2 82 DP OUE NIESIA OS o 6 copon oe a a A Be AA E a E a 149 2 83 TAPAGIG MESSag S o o oc oua e be GO eae he we ea eae A 150 2 84 TCP Messages 05 a Sh ee SP Se Se ES Bee a ad Bee i 151 2 85 TRANSCEIVER Messages og us Se Sek HAY Re eee eR Se ee ee 152 2 86 TUNNEL Messe ee oops BHM E OS hie ee Bw ob eek oe ed We whe bs 153 2 87 NM Messan os con ge ee ok ae Eee Be AR Ee wh ewe ee Boe ed 154 2 88 VMTRACBRSESS Messages v ceri a wb SNS Ee o BAS 155 2 89 VMWAREVE Messages oeoc e AR Se a eR A ew eR Sb as 156 2 90 VNIWAREVS Messages 5 55 24 eera e a A 157 2 91 ld IA 158 2 92 VRRP Messages 6 coin p eae e E e ea eee A 159 2 93 YXLAN Messagi 00 ee bag ee a ok GAE a a eap o e Ge ae Soe eee Bow amp 161 EOS User Manual ii CONTENTS 2 94 XAMPP WMessageS 200 ac baw o A e a A 164 2 95 AUP DMESSADOS o co ks ria Bee a ee eh poate Gea Be he Bel Gem a 165 EOS User Manual iii CHAPTER 1 SYSTEM MESSAGE OVERVIEW Chapter 1 System Message Overview 1 1 Message Format System Messages on EOS have the following format timestamp hostname process seq_number FACILITY Severity Mnemonic Message text Here s an explanation of each of the fields timestamp This is the time the message was generated The time is obtained from the clock on the switch You should configure the clock to get an accurate timestamp or use NTP hostname The hostna
54. 5535 or remove the SVI configuration on the VLAN Please contact your technical support representative if you need additional assistance EOS User Manual 162 CHAPTER 2 SYSTEM MESSAGES STATIC _VLANVNI INVALID CONFIG INTERNAL Configured VLAN to VNI mapping has been ignored VLAN d has already been allocated internally Severity Warning Explanation A configured VLAN to VNI mapping has been ignored because the specified VLAN has already been internally reserved by a routed port Recommended Action Change the VLAN configured in the mapping STATIC_VLANVNL INVALID CONFIG PEERLINK Configured VLAN to VNI mapping has been ignored VLAN d has already been allocated to the MLAG peer link SVI Severity Warning Explanation A configured VLAN to VNI mapping has been ignored because the specified VLAN has already been allocated to the MLAG peer link SVI Recommended Action Change the VLAN configured in the mapping VLAN_UNSUPPORTED VXLAN is not supported on VLAN 1 Severity Error Explanation Mapping VLAN 1 to a VXLAN VNI is unsupported on this platform Recommended Action To solve this issue remove the VNI mapping for VLAN 1 Please contact yourtechnical support representative if you need additional assistance VTEP_DEFAULT_ENTRY_HW_RESOURCE_FULL VXLAN initialization failed due to insufficient hardware resources Severity Error Explanation The switch is unable to initialize VXLAN in hardware so VXLAN forwarding may not wo
55. A network administrator has replaced the running configuration of the system successfully Recommended Action No action is required this message is for information only CONFIG _SESSION_ABORTED User s aborted configuration session s on s s Severity Notice Explanation A network administrator has aborted a configuration session thereby having no effect on the running configuration of the system Recommended Action No action is required this message is for information only CONFIG SESSION COMMIT CONFIRMED SUCCESS User s committed session s on s s pending confirmation Severity Notice Explanation A network administrator has commit confirmed aconfiguration session thereby modifying the running configuration of the system temporarily Recommended Action No action is required this message is for information only CONFIG SESSION_COMMIT_CONFIRM_ABORT The last commit confirm operation has been aborted The system config has been rolled back Severity Notice Explanation Commit confirm has been aborted manually Recommended Action No action is required this message is for information only CONFIG _SESSION_COMMIT_CONFIRM FAILURE User s commit confirm operation in configuration session s failed on s s Severity Notice Explanation This failure happened because another session is in confirming state Recommended Action No action is required this message is for information only CONFIG _SESSIO
56. A running process has been configured to stop or its configuration has changed ProcMgr will stop the process and will restart it with a new configuration if applicable Recommended Action This message is informational only no action is required UNEXPECTEDCFGFILESGONE d files disappeared from s but no SIGHUP to ProcMgr Gone are s Severity Warning Explanation ProcMgr has discovered that some process config files have disappeared without ProcMgr being informed Running processes will not be stopped by ProcMgr which is probably not the intention Recommended Action Figure out why the files disappeared and why ProcMgr was not told to rescan the directory by sending ProcMgr a SIGHUP UNEXPECTEDNEWCFGFILES d new config files in s but no SIGHUP to ProcMgr New are s Severity Warning Explanation ProcMgr has discovered process config files that it was not told about The processes will not be started by ProcMgr which is probably not the intention Recommended Action Figure out where the files came from and why ProcMgr was not told to rescan the directory by sending ProcMgr a SIGHUP WORKER _COLDSTART New ProcMegr worker cold start PID d Master ProcMgr PID d Severity Info Explanation The ProcMgr worker thread is ready to begin its work Recommended Action No action is required this message is for information only WORKER RESTART ProcMgr worker PID d terminated unexpectedly starting new worker
57. ARE_HOT_REMOVAL Detected hardware hot removal in Strata switching ASIC s Severity Info Explanation A hardware hot removal was detected in a Strata switching ASIC Recommended Action No action is required this message is for information only HITLESS_INIT_INTF_POSSIBLE_FLAP Link may have flapped on s while the forwarding agent was down Severity Info Explanation Possible link flap was detected on an interface while the forwarding agent was down due to hitless restart Recommended Action No action is required this message is for information only HITLESS_RESTART_MMU_SCHED_CHANGED MMU scheduler structure is changed during agent hitless restart the StrataAgent will restart in normal mode resulting in forwarding outage Severity Info Explanation When StrataAgent restarts in hitless mode MMU scheduler structure is checked to make sure software and hardware is in sync if not switch ASIC will be reconfigured requiring the StrataAgent to restart in normal mode Recommended Action This behavior is expected HITLESS_RESTART_TIMEOUT Hitless restart of StrataA gent timed out The agent will restart in normal mode resulting in a forwarding outage Severity Error Explanation StrataAgent failed to determine link statuses for all interfaces within the allotted time during hitless restart The agent will restart in normal mode resulting in a forwarding outage Recommended Action If the problem persists contact your support re
58. ARISTA EOS System Message Guide Software Release 4 15 2F September 26 2015 http www arista com email support arista com Contents 1 System Message Overview 1 1 1 Message Format gn 6 cee oe EN RR ER a RR 1 Le SN Levels e e AAA e A A RES 2 2 System Messages 3 2 1 ARA Meines aa a A A A A es A A i 3 2 ACCOUNTING Messages oo a A we EA ee 7 2 3 HAELMIESSIDES ooh ke a OE a o amp a aah i 8 2 4 AGENT Messages osc cre re A A A Se 9 23 ARF MESARE li E bee te A A Bee oe De ee eS 10 2 6 BPD Messages see Sa ek oe eae be ee Ba eee ee ha ee ee eee 11 cae A sh chee Se Bae Se EHS Be eA OER ESSE Che 12 2 8 BIDIR Messalo sos e eo WAS A A ee Re E Ee Shee Bee 14 28 CARS TEY MESSOBES 6 od bate g Sith A Ge e Ban eS 15 2 10 CAPI MESSIES o ka od ee eRe EE Se SR Pee ee eee ee Ee eS 16 2A CARDIMESSADES 6 Ghee be A ea eae ee ee ee eee ea 17 2 12 CLEAR Messages pc ek ka ro a aS ae Be eS Ge Bow 18 213 DATAPLANE Messages fc ea eA Ea Dee a es 19 2 14 DUTIA Messages oc reor eea A a Ree A OR ee ee GSS 21 2 15 ENVMON Messages coccion OA ewe ee bee ee was 23 2 16 PATEL MESSIER host a eG ae eee ae eee eee Ss oS 28 217 EVENTMON ME8saBes ocu ss a a a Bee 32 2 18 EXTENSION Messages 20 is as We Bae e es 33 2 19 PHIRP IASSSHgES soto doses eR RE ESR AAA eRe Ee Ee eS 34 2 20 PLAY Message on al tk BR eH de a 35 2 21 FOCALPOINTV2 Messages oc copa soona ome Re ee eee 36 2 22 FRU Messages cc e A eae ee eS 39 2 23 FWK INIESSADeS sao eG BAERS ER Bae a LES PE
59. AST_EXPECTED Event handler action s with PID d is running longer than expected Severity Warning Explanation Currently running event handler action is running longer than the expected action timeout Recommended Action Speed up the action or increase the timeout EVENT_TRIGGERED Event handler s was activated Severity Info Explanation Event handler actions are configured from Cli to run when certain conditions are met To see currently configured event handlers run show event handler from enabled mode Recommended Action No action is required this message is for information only KERNEL PANIC Reboot due to kernel panic Severity Error Explanation The system rebooted due to a kernel panic Recommended Action This may indicate a serious hardware or software problem Contact your customer support representative LOGMSG_ALERT Message from s on s s s Severity Alert Explanation As a result of send log command from the CLI Recommended Action No action is required this message is for information only LOGMSG CRIT Message from s on s s s Severity Critical Explanation As a result of send log command from the CLI Recommended Action No action is required this message is for information only LOGMSG_DBG Message from s on s s s Severity Debug Explanation As a result of send log command from the CLI Recommended Action No action is required this messag
60. Action If the problem persists contact your support representative Otherwise no action is required FABRIC_MCAST_TABLE_INIT_TIMEOUT Fabric Chip s timed out during initialization of multicast tables Severity Warning Explanation The multicast tables in the specified fabric chip were not properly initialized before enabling traffic to be switched by the fabric chip This may result in loss of multicast traffic during system boot up and fabric agent restart Recommended Action If the problem persists contact your support representative Otherwise no action is required FABRIC_NOT_PRESENT s can no longer access the switching fabric stopping all traffic Severity Error Explanation The chassis s fabriccards have been removed or are not working The chassis must have working fabriccards for traffic to forward Recommended Action Reinsert the fabriccards EOS User Manual 118 CHAPTER 2 SYSTEM MESSAGES FABRIC_REQUEST_AUDIT Request audit of switch fabric Severity Info Explanation Switch fabric audit was requested by CLI command Recommended Action No action is required this message is for information only FE600_RESTORED_TO_FABRIC s restored to the switch fabric Severity Warning Explanation Switch fabric redundancy has been restored Recommended Action No action is required this message is for information only FE600_WITHDRAWN FROM FABRIC s withdrawn from the switch fabric causing some loss in r
61. Buffer usage is under low threshold now Maximum buffer usage is d segments Severity Info Explanation Global buffer usage is under threshold Recommended Action No action is required this message is for information only GLOBAL BUFFER USAGE OVER THRESHOLD Global Buffer usage is over threshold of d current length is d Severity Info Explanation Global buffer usage update Recommended Action No action is required this message is for information only HW_RESOURCE_FULL s Severity Error Explanation The ASIC is unable to program all LANZ configuration due to insufficient hardware resources Recommended Action Reconfigure LANZ to reduce the amount of resources needed LENGTH_OVER_THRESHOLD s Severity Info Explanation Interface queue length is over threshold Recommended Action No action is required this message is for information only LENGTH_UNDER_THRESHOLD Interface s max queue length was d now back under low threshold of d Severity Info Explanation Interface queue length is back under low threshold Recommended Action No action is required this message is for information only LENGTH_UPDATE s Severity Info Explanation Interface queue length and queue drop update message Recommended Action No action is required this message is for information only MIRROR_HW_RESOURCE_FULL Mirroring hardware resources are insufficient to enable LANZ packet sam pling Packet sampling will be
62. CERS Hardware resources to enable counting is not available Severity Info Explanation Counting disabled for some Static NAT connections Recommended Action No action is required this message is for information only PCIE_ERROR PCIE Error occurred in FocalPoint chip s Severity Error Explanation FocalPoint agent restarted in order to recover from this error Recommended Action No action is required this message is for information only POLICER BANK FULL Hardware resources are insufficient to program all NAT rules Severity Error Explanation The switch is unable to program all NAT rules due to insufficient hardware policer banks Recommended Action To solve this issue remove features that are using policer banks from the configuration POLICER_BANK_NORMAL All new dynamic NAT connections will be programmed in hardware Severity Error Explanation The switch will program all new dynamic NAT connections in the hardware all existing connections will continue to be translated in software Recommended Action No action is required this message is for information only POLICER PARAMETERS INCONSISTENT The burst capacity configured in s for service policy s is not sufficient for the hardware to achieve the programmed CIR Severity Info Explanation Operational CIR might be less than CIR configured Recommended Action No action is required this message is for information only EOS User Manual 38 CHAPTER 2
63. Card s was power cycled due to s Severity Error Explanation A card power cycle is used to attempt recovery of an error Recommended Action If the problem persists contact your support representative Otherwise no action is required CARD_RESET Card s in state s was reset due to multiple failed power on attempts Severity Error Explanation A card was reset in an attempt to recover from an error It may appear that the card was removed from the system momentarily Recommended Action If the problem persists contact your support representative Otherwise no action is required CARD TEMP ALERT ERROR Temp Alert has been asserted on s Severity Error Explanation Software detected a problem with temperature on a card in the system Recommended Action If the problem persists contact your support representative Otherwise no action is required CHIP_BAD_VERSION Cannot access s s Unexpected version d Severity Error Explanation The version of this chip is not what was expected This probably means the read of the version register failed and we cannot access the chip s registers Recommended Action Remove and insert the card CHL822X_UPGRADED Successfully upgraded Ch1822X device to version d Severity Info Explanation Device was successfully upgraded Recommended Action No action is required this message is for information only CHL822X_UPGRADEFAILED Failed to perform an upgrade of the Ch1822X device
64. D Forwarding mode restricted to store and forward due to VXLAN and 1G interfaces Severity Warning Explanation Cut through forwarding mode is not supported when there are 1G interfaces and VXLAN is configured Recommended Action No action is required this message is for information only CUT_THROUGH ENABLED Forwarding mode no longer restricted to store and forward due to VXLAN and 1G interface Severity Warning Explanation Forwarding mode no longer restricted to store and forward due to VXLAN and 1G interface Switching to cut through default if the forwarding mode is not configured Recommended Action No action is required this message is for information only MACTABLEENTRYCLEAR Mac Table overflow condition for multicast group s in VLAN d has cleared Severity Warning Explanation The entry has been programmed and traffic should not flood for this group Recommended Action Okay to use this IP multicast group MIRROR_SESSION_ RESOURCES_FULL Mirroring hardware resources are insufficient to program the mirror session s Severity Error Explanation The switch is unable to program the mirroring session due to the unavailability of hardware resources The maximum mirror sessions limit has been exceeded As a result this mirroring session is not operational Recommended Action To solve this issue remove a mirroring session or unconfigure a feature that is using a mirror session MIRROR_SOURCE_RESOURCES FULL Insufficient har
65. DEVICE_UNSUPPORTED Device in slot s is not supported Severity Error Explanation The device inserted in the above slot is unknown and not supported by the software Recommended Action Replace the device with a one supported by the version of your software FAN INSERTED s has been inserted model s serial number s Severity Info Explanation The specified fan has been inserted Recommended Action No action is required this message is for information only FAN_REMOVED s has been removed model s serial number s Severity Info Explanation The specified fan has been removed or is not properly seated Recommended Action Reinsert the fan or check that the fan is properly inserted FAN UNSUPPORTED s is unsupported Severity Error Explanation The specified is not supported by the running software Recommended Action Check that the version of software you are running supports the specified fan type Upgrade software or replace the fan NOLBTDUMP Unable to determine Aboot firmware version s Severity Error Explanation nvramtool btdump command failed Recommended Action No action is required this message is for information only POWERSUPPLY DRIVER Fatal software failure for the power supply in slot s Severity Error Explanation A fatal error occurred when attempting to instantiate management software for the power supply Recommended Action Upgrade software to the current release Contact support if
66. ECMP route a has exceeded number of allowed paths Severity Info Explanation An ecmp route has more paths than allowed by the Resilient Ecmp Feature The extra paths will not be programmed in hardware Recommended Action No action is required this message is for information only ECMP_ROUTE PATH NOT PROGRAMMED Path a not programmed for ECMP route a Severity Info Explanation Path exceeds number of allowed paths in a resilient ecmp route Path will not be programmed in hardware Recommended Action No action is required this message is for information only HW RESOURCE FULL Hardware resources are insufficient to program all routes Severity Error Explanation The switch is unable to program all routes due to insufficient hardware resources When the switch is unable to program routes due to insufficient hardware resources it may drop certain packets in order to avoid potential routing loops in the network The switch encountered this issue because the routing table exceeds the available hardware resources Recommended Action To solve this issue reconfigure the network to reduce the size of the routing table When the routing table size reduces the switch automatically programs any unprogrammed routes in hardware HW RESOURCE NORMAL All routes are programmed in hardware Severity Error Explanation The switch was able to program all the routes in the routing table in hardware and normal hardware routing has resumed
67. Egress counters have returned to normal The chip is operating normally Recommended Action No action is required this message is for information only EOS User Manual 117 CHAPTER 2 SYSTEM MESSAGES EGRESS INCONSISTENT Egress buffer counters on s are inconsistent with the number of available buffers and or descriptors The egress queues may be stuck causing traffic sent to this device to be dropped Severity Error Explanation Egress counters are showing more buffers or descriptors than actually exist Recommended Action If the problem persists contact your support representative Otherwise no action is required ERROR_OCCURRED s s occurred New d Total d Severity Error Explanation An unusual event has been detected Recommended Action If the problem persists contact your support representative Otherwise no action is required ESEM RESOURCE FULL Hardware resources are insufficient to program all entries in ESEM table Severity Error Explanation The switch is unable to program all sub intfs or vlan mappings due to insufficient hardware resources Recommended Action Reconfigure your network to reduce the number of sub intfs or vlan mappings in the switch ESEM RESOURCE NORMAL Hardware resources to program sub interfaces or vlan mappings are recovered Severity Error Explanation The switch was able to program all sub intfs vlan mappings in hardware Recommended Action No action is required th
68. FAILED User s failed authorization to start a shell Severity Warning Explanation AAA server denied authorization to start a shell Recommended Action Confirm that the user settings on authorization server s are correct HOMEDIR_SETUP_ERROR A problem occurred setting up the home directory for user s Severity Warning Explanation AAA creates a home directory at the time of a user s first login and may populate it with some settings files A problem occurred during this process and the user s home directory may not have been created or may be partially populated Recommended Action Log out and log back in Contact your support representative if error persists INCOMPLETE_LOGINS_LIMIT Too many incomplete login attempts Severity Error Explanation AAA has received too many incomplete login attempts within the last 5 minutes Login via console is available but login via ssh or telnet may fail until some of the incomplete login sessions expire Recommended Action Investigate whether the device is being attacked Attempt login via the console Contact your support representative if error persists INVALID_ACCT_METHODLIST Invalid accounting method list configured for action s method s is unknown Severity Error Explanation An attempt to account for an action failed because the method list configured for the action contains a method name that does not match any available accounting plugins Recommended Action F
69. Gs ba es 43 2 24 GMP Message na eae eA bea ee he eb a dea ee eee bea es 44 2 23 HARDWARE Messages oo ka A Be RO Re ee pe ee ee 45 2 26 IOMP MGShA G68 oo a a a a ek ee ke ee al ee EE Y 58 2 24 GMPSNOGPING Messages e cusco BH e Pee eee Ca eS 59 2 28 UNT Messages lt a cios pas eR MEP ERR Pe AAA A A 60 229 IPOROUTING Messages oo ida o a E A a he e a A 61 2 30 IRA Messages lt a dro ER E IR E EE NA AE es 62 Zal DE MSE ARAN 63 2 32 KERNELFIB Messapes oios e ba RE E E e E A E eG O 64 2 33 LACP Messagg oo comia o de A as 65 2 34 LAG Message s o ac AA A A a a 66 2 30 LAUNCHER Messages oao bk erua d a a A 67 2 36 LINEPROTO Messages esca isso Ba es a a A ee a Ge a 68 2AT LLDP IMIESSAD S eA eA o e ee Ga e Ped ee ea J 69 2 38 LOGMGR Messages orae bees EA i eee bb ee eee hoes 70 CONTENTS 2 39 LOOPBACK Wessages on coos be ea a a AA 71 2 40 LOOPPROTECT Messages ic oc ck 8 oa ea a a oe a 72 2 41 LSPPING Messages ee ce a A ee ea eae 73 2 42 MAPREDUCEMONITOR Messages 0 2 4 5 8 See eye eA EROS EH OSS 74 2 43 MAX24905 MEESEBES oe ee ep eb eee we RA 75 2 44 MOIO MOIES ope eS SEE A in dt E 76 2 45 MIRRORING Messages oeo g sisas as RR e ER e AR 77 2 46 MEAG MESAS m iine kde ee A ged de bootie Sted Blears oe Ace A 78 2 47 MMODE Messages opaca pos OS Rw Ee RE ER RRA 81 2 48 MROUTE Messages ra e ek e ee bea a 82 2 49 MRP Messages oo opo bd ee a ee Bee ea Ee Be we ele ee 83 2 50 MSDP VISESADOS 0 ae See AREER AE OAR ewe ee AE ERR ERE Sas 84 2 51
70. IFICATION FAILED Failed to identify the slot id of the supervisor Severity Emergency Explanation Hardware returned inconsistent results when determining the slot id of the supervisor from hardware System functionality may be severely limited Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved SUPERVISOR _PCIE_LINK_ERROR The Pcie link to the CPU has failed Severity Emergency Explanation Software detected a link failure between the CPU and one of its two Pcie switches this will prevent the system operating correctly Recommended Action Reboot the switch to try to recover the failure and contact your support representative for assistance SUPERVISOR PCIE SWITCHOVER s is being switched over to the standby supervisor Severity Info Explanation Software detected a change in the active supervisor hardware control is being transferred to the this supervisor Recommended Action No action required SUPERVISOR_PCIE_SWITCHOVER FAILURE Unable to switch s over to the standby supervisor Severity Error Explanation Software detected a change in the active supervisor but was unable to switch this card over to the standby supervisor Recommended Action If this problem persists please contact your support representative for assistance SUPERVISOR _PCIE_SWITCH BUS ERROR Unable to switch s o
71. IPv6 Egress ACL that was applied to interface s will now be installed Severity Info Explanation IPv6 Egress ACLs on routed ports are supported Since the interface has become a routed port the previously configured IPv6 Egress ACL will now be installed Recommended Action No action is required this message is for information only IPV6_ERACL_SWITCHPORT The IPv6 Egress ACL applied to switchport s will not be installed until the switchport is converted to a routed port Severity Info Explanation IPv6 Egress ACLs on switch non routed ports are not yet supported but the user configuration will be stored The ACL will become active when the interface is changed to a routed interface Recommended Action No action is required this message is for information only IPV6_RACL_DSCP IPv6 ACLs with DSCP will not be applied to VLAN interfaces Severity Info Explanation This platform does not support the application of IPv6 ACLs with DSCP to VLAN interfaces Recommended Action No action is required this message is for information only MACACCESS list s s s Ps Ps s Ps Severity Info Explanation A packet has matched one of the rules with log option in the specified MAC access list Recommended Action No action is required this message is for information only EOS User Manual 8 CHAPTER 2 SYSTEM MESSAGES 2 4 AGENT Messages EXCESSIVE WARMUP DELAY Agent s experiencing excessive warmup delay Severity
72. MSRP MGSSAGGS ciar A e a A RA a BAS 85 2 32 MVEP Message o eo eea ee EL A A 87 piet NAT INIESE EEN air I a ee BEES ES Shwe a 88 2 54 CPENPLO Messages cocos es a a o a a as 89 2 COPE OBO ee ton NA we Mice eo 90 2 56 LISPESIMESSAB S serana res roda AA EA 91 237 PEE MESOS ia A E AS AN A A EREE A 92 2 58 PIM Messages so soere dopa ba mop eoe ERAS p ee e ke Ba Ba oe 8 93 2 39 PIVIBSR MESSIC S oc cco ee BRERA ERA we EAS 94 2 60 PORISECURTEY Message a ono pi DRAG a EAS OS eR EEE SSS 95 2 61 PREFIX Messages oec occ be eee a eee eee A E 96 2 62 PROCMOR Messages oo cos c RD Ae OS sa a 97 2 63 PUP MESSA 2 4 4 2 caw ee eal A Ye ie a ed he AA 102 2 64 PREMEDITMISESAgES lt oo ee A Se BOR Ye e is 103 2 65 QOS MESESBES oran AAA 104 2 66 OUARTZA Y Messares o ic A A A ee ee A 106 2 67 QUBDEMONITOR Messages o v sc A RR RR AR 107 2 68 REACHABILITYMONITOR Messages 24 0 4 5450544 pe wR res bee es 109 2 69 REDUNDANCY Messages cocoa Re A A ea A eR aS 111 2 20 RIB VIESSALES orar a e A 113 2 11 ROUTING Messages o oos ke ee A A a ae AA E i ee Se sa 114 aE SAND MESSAGER a He AR ae ee KR ee ee ea eS Y 117 2 3 gt ANDACL Messages aida SA a A a BOER a A SO 8 126 2 74 SANDTOPO Messages Lc errado A a 127 Ee SP URULY MESI rEg i Bo fo kee et Ree eee OAS bee eke Pere 128 2 76 SERVERMONITOR Messages ka coke OER eR OAR RO ER OO 132 271 Sr RE MoS id e a a RA A 133 248 A IN 137 249 S TAGEMGR o nee os n A EAR RE EEE OEE BH LES EA EE RASS 138 2 80 STRATA MESSADES 2
73. N MISMATCH Incorrect multicast replication entry detected in hardware Severity Error Explanation The software has detected a multicast replication entry incorrectly programmed in hardware The entry has been automatically corrected Recommended Action No action is required this message is for information only MPLS_RESOURCE_FULL Hardware resources are insufficient to program all MPLS routes Severity Error Explanation The switch is unable to program all routes due to insufficient hardware resources When the switch is unable to program routes due to insufficient hardware resources it may drop certain packets Recommended Action To solve this issue reconfigure the network to reduce the size of the routing table or the number of MPLS routes When the hardware resources is available the switch automatically programs any unprogrammed routes in hardware MPLS_RESOURCE NORMAL All MPLS routes are programmed in hardware Severity Error Explanation The switch was able to program all the MPLS routes in the hardware and normal hardware routing has resumed Recommended Action No action is required this message is for information only NO EGRESS RACL SHARING OVERRIDE _URPF Unicast RPF is re enabled since no egress router ACLs are configured Severity Warning Explanation Unicast RPF configuration is active again since no egress router ACLs are configured Recommended Action No action is required this message is for informa
74. N_COMMIT_CONFIRM_TIMEOUT The last commit confirm operation has been aborted due to timeout The system config has been rolled back Severity Notice Explanation Commit confirm has timed out Recommended Action No action is required this message is for information only CONFIG SESSION COMMIT FAILURE User s committed configuration session s with errors on s s Severity Error Explanation A network administrator has commited a configuration session but the operation failed The system may be in an inconsistent state Recommended Action No action is required this message is for information only CONFIG SESSION COMMIT_ SUCCESS User s committed configuration session s successfully on s s Severity Notice Explanation A network administrator has commited a configuration session thereby modifying the running configuration of the system Recommended Action No action is required this message is for information only CONFIG SESSION DELETED User s deleted configuration session s on s s Severity Notice Explanation A network administrator has deleted a configuration session thereby having no effect on the running configuration of the system Recommended Action No action is required this message is for information only CONFIG SESSION ENTERED User s entered configuration session s on s s Severity Notice Explanation A network administrator has entered a configuration session Recommended Actio
75. No action is required this message is for information only SERVER PROXY LIMIT EXCEEDED Maximum number of servers that can be proxied simultaneously has been reached Severity Notice Explanation A maximum of 256 servers can be proxied simultaneously No additional failed server will be proxied after that limit has been reached Recommended Action No action is required this message is for information only SERVER_PROXY_LIMIT_NO LONGER EXCEEDED Number of servers that are currently being proxied is below the maximum simultaneously proxied server limit Severity Notice Explanation The number of servers currently being proxied is less than the maximum limit of 256 Additional failed servers will be proxied from now on Recommended Action No action is required this message is for information only SERVER PROXY START Proxy service started for server s on interface s Severity Notice Explanation Proxy service for the server has started Any host that sends traffic to the server will be notified that the server is down Recommended Action No action is required this message is for information only SERVER_UP Server s is up on interface s Severity Info Explanation Server is connected and active on the interface Recommended Action No action is required this message is for information only EOS User Manual 132 CHAPTER 2 SYSTEM MESSAGES 2 77 SPANTREE Messages BLOCK BPDUGUARD Received BPDU pa
76. OMPATIBLEFANSDETECTED Incompatible fans have been detected If not resolved the system will be shut down in d minutes Severity Emergency Explanation All fans must be the same type i e front to back or back to front but at least one miss matched fan has been detected The system will be shut down if the problem is not resolved Recommended Action Check that all fans are of the same type i e front to back vs back to front airflow and replace any differing fan s immediately EOS User Manual 24 CHAPTER 2 SYSTEM MESSAGES INSUFFICIENTFANSDETECTED Too few working fans detected If not resolved the s will be shut down in od minutes Severity Emergency Explanation Not enough fans of the correct type are functioning and the system will be shut down if the problem is not resolved Recommended Action Check that all fans are inserted and still spinning and replace any missing or broken fans immediately INSUFFICIENTFANSSHUTDOWN s being shutdown due to insufficient or incompatible fans Severity Emergency Explanation Too many fans have failed or are missing or incompatible fans have been detected The system is being shut down to prevent damage Recommended Action Replace all broken missing or incompatible fans immediately POWERSUPPLY OVERHEAT CRITICAL s temperature critical Severity Emergency Explanation The specified power supply has surpassed its critical temperature Recommended Action Check that syste
77. OVERHEAT_CRITICAL s is reporting sC which is above its critical threshold of dC Severity Emergency Explanation The specified temp sensor is reporting a temperature above its critical threshold The system will disable the overheating component to prevent damage Recommended Action If the problem persists contact your support representative Otherwise no action is required TEMPSENSOR_OVERHEAT_WARNING s is reporting sC which is above its overheat threshold of dC Severity Error Explanation The specified temp sensor is reporting a temperature above its overheat threshold indicating a component is overheating Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 26 CHAPTER 2 SYSTEM MESSAGES TEMPSENSOR_TEMP_NORMAL s is reporting sC which is within the normal range Severity Error Explanation The specified temp sensor was overheating but has now returned to a normal operating temperature Recommended Action If the problem persists contact your support representative Otherwise no action is required XCVR_OVERHEAT_ CRITICAL s temperature critical Severity Emergency Explanation The specified transciever has surpassed its critical temperature Recommended Action Check that system fans are operating correctly If the problem persists please contact your support representative for assistance XCVR OVERHEAT WARNING s is overheating
78. OWNLOAD SUCCESS Successfully downloaded s from s Severity Notice Explanation Zero Touch Provisioning successfully downloaded the startup config or a config script from the URL specified in the received DHCP response Recommended Action No action is required this message is for information only CONFIG DOWNLOAD_TIMEOUT Timed out trying to download the startup config or a config script from s after You seconds Severity Warning Explanation Zero Touch Provisioning timed out trying to download the startup config or a config script from the URL specified in the received DHCP response To cancel Zero Touch Provisioning type zerotouch cancel at the CLI Recommended Action If the problem persists contact your support representative Otherwise no action is required DHCP_QUERY Sending DHCP request on s Severity Notice Explanation Zero Touch Provisioning is trying to discover a DHCP server on the network Zero Touch Provisioning will only accept a DHCP response with a valid DHCP option 67 present To cancel Zero Touch Provisioning type zerotouch cancel at the CLI Recommended Action No action is required this message is for information only DHCP_QUERY FAIL Failed to get a valid DHCP response Severity Notice Explanation Zero Touch Provisioning failed to get a DHCP response with a valid DHCP option 67 answer from a server on the network Check your DHCP server for proper Zero Touch Provisioning configuration To cancel Ze
79. Point agent restarted in order to recover from this error Recommended Action No action is required this message is for information only EOS User Manual 36 CHAPTER 2 SYSTEM MESSAGES EACL VLAN _INNER_VLAN_MATCH IGNORED Vlan inner vlan match in Egress ACL s are supported only in TapAgg mode Severity Info Explanation Rules in Egress ACLs having vlan inner vlan match will be applied without vlan inner vlan match condition Recommended Action No action is required this message is for information only FFU_BST_CONFIG CHANGE Change in allowed FFU BST features configuration requires a restart of the FocalPointV2 agent Severity Info Explanation FFU BST will be re initialized at bootup with new configuration Recommended Action No action is required this message is for information only LOADBALANCE_HASH_PROFILE_SM_FULL The Hash Profile s is not programmed in the hardware Severity Info Explanation Hash Profiles Limit has been hit Recommended Action No action is required this message is for information only LOADBALANCE_PAYLOAD_FIELD_IGNORED Load balancing on s field is supported only in tap aggrega tion mode Severity Info Explanation Custom fields will not be included in the load balance hash calculation for this profile in non tapagg mode Recommended Action No action is required this message is for information only MLAG_ MIRROR HW RESOURCE FULL Mirroring hardware resources are
80. Role s has an invalid regular expression Severity Error Explanation The specified rule has an invalid regular expression and will not take effect until the syntax is fixed Recommended Action Fix the role configuration INVALID_TACACS SERVER TACACS server s port d could not be used s Severity Warning Explanation The configuration contains a TACACS server that could not be used One cause for this type of error is a hostname for which DNS resolution fails Recommended Action Correct the TACACS server configuration LOGIN user s logged in from s service s Severity Notice Explanation A user has logged in successfully Recommended Action No action is required this message is for information only LOGIN_FAILED user s failed to login from s service s reason s Severity Warning Explanation A user has failed to login to the switch Recommended Action No action is required this message is for information only LOGOUT user s logged out from s service s Severity Notice Explanation A user has logged out or the session has terminated Recommended Action No action is required this message is for information only NO_VALID_RADIUS_SERVERS No valid RADIUS servers for method list s Severity Error Explanation The configuration contains an authentication method list that is not associated with any valid RADIUS servers One common cause for this error is a hostname f
81. SH tunnels If this doesn t explain why the SSH Tunnel is restarting so often check the tunnel logs under etc ssh SSH_TUNNEL_SWITCH_HOSTKEY_DENIED SSH tunnel s was unable to log into its configured host via public key authentication Severity Error Explanation The SSH tunnel attempted to log into the configured host with the switch s hostkey and was denied Recommended Action Check that the switches public hostkey is installed on the remote host for the username that is being used to log in SSH_TUNNEL_TIMEOUT SSH tunnel s had the remote host timeout while connected Severity Error Explanation The SSH tunnel periodically sends server alive messages through the tunnel and timed out on receiving areply for them Recommended Action Check that the remote host has it s SSH server running and if it has any error messages in its log SSH_TUNNEL_UNCONFIGURED SSH tunnel s from local TCP port s to s s via s s has been unconfigured Severity Info Explanation An SSH tunnel to a remote server just stopped running and will not be automatically restarted since it was terminated by a command Recommended Action No action is required this message is for information only EOS User Manual 130 CHAPTER 2 SYSTEM MESSAGES SSL_DIFFIE_HELLMAN PARAMETERS INIT FAILED Initializing SSL Diffie Hellman parameters failed Try reset ssl diffie hellman parameters to recover Severity Error Explanation Attempt to initiali
82. Shape rate is in s and Bandwidth guaranteed is in s causing unit mismatch for queue s on port s Not programming s Severity Error Explanation Both Shape rate and Bandwidth guaranteed have to be in same units to be programmed properly in hardware Recommended Action Reconfigure shaperate units or bandwidth guaranteed units EOS User Manual 105 CHAPTER 2 SYSTEM MESSAGES 2 66 QUARTZY Messages INIT FAILED Possible hardware error with the Quartzy chip Severity Error Explanation Initialization of the Quartzy chip has failed Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 106 CHAPTER 2 SYSTEM MESSAGES 2 67 QUEUEMONITOR Messages AGENT_RESTART Queue monitor on s has experienced an irrecoverable error restarting queue monitoring agent to recover Severity Warning Explanation Queue monitoring agent will restart immediately Possible loss of congestion records may occur during the restart Recommended Action No action is required this message is for information only COPROCESSOR_ERROR Queue monitor on s has experienced an error some congestion events may be lost Severity Warning Explanation Queue monitoring has stalled briefly Possible loss of congestion records may occur while it recovers Recommended Action No action is required this message is for information only GLOBAL_BUFFER_USAGE_LOW_THRESHOLD Global
83. THENTICATED Supplicant with identity s and MAC s successfully authenticated on port Ps Severity Info Explanation A supplicant was successfully authenticated on a 802 1X enabled port Recommended Action No action is required this message is for information only EOS User Manual 21 CHAPTER 2 SYSTEM MESSAGES SUPPLICANT_FAILED_AUTHENTICATION Supplicant with identity s and MAC s failed authentication on port s Severity Error Explanation A supplicant attempted to authenticate using 802 1X but did not have the proper credentials Recommended Action Verify the credentials the supplicant has for the identity it provided SUPPLICANT LOG OFF Supplicant with identity s and MAC s has logged off of port s Severity Info Explanation A supplicant that was associated with an 802 1X port has logged off of it Recommended Action No action is required this message is for information only SUPPLICANT MULTIPLE SUPPLICANTS COMMUNICATING Supplicant with MAC s on port s attempted to communicate using the 802 1X protocol but MAC s is already associated with this port Severity Warning Explanation Only one MAC address can be associated with an 802 1X port at a time for communicating 802 1X operations Recommended Action Investigate if the latter supplicant should be the one authenticating The former supplicant will need to log off or time out to allow the latter supplicant to authenticate SUPPLICANT_TIMEOUT Supplica
84. TP capable peer was detected on this link Recommended Action No action required EOS User Manual 102 CHAPTER 2 SYSTEM MESSAGES 2 64 PWRMGMT Messages INPUT POWER LOSS s has lost input power Severity Warning Explanation The power supply has lost input power Recommended Action Check the input power source to the power supply and that the power supply is properly plugged in If the problem persists contact your support representative Otherwise no action is required INPUT POWER OK s has regained input power Severity Warning Explanation The power supply had previously lost input power but is now ok Recommended Action No action is required this message is for information only PSU_STATUS_FAILED s has failed and has stopped providing power to the system Severity Error Explanation The power supply has failed and is no longer providing power to the system Recommended Action Check the output of show environment power and other log messages for details of why the power supply failed The power supply may need to be replaced The problem should be fixed as soon as possible to avoid potential downtime in the future PSU_STATUS_OK s has recovered and is providing power to the system Severity Error Explanation The power supply had previously failed but is now ok and is once again providing power to the system Recommended Action Check for other log messages detailing why the power supply originally
85. T_FAILURE Power supply d has failed because the reported output current sA is outside the valid range Overall system load is sA Severity Error Explanation The power supply has failed and is no longer providing power to the system Recommended Action Replace the power supply POWER_SUPPLY_OUTPUT_UNDERVOLTAGE_ WARNING Power supply d output undervoltage detected latest reading dV Severity Warning Explanation The power supply has flagged an output undervoltage warning If the problem persists the power supply will shut down Recommended Action If the problem persists contact your support representative Otherwise no action is required POWER SUPPLY OVERHEAT WARNING Power supply d is overheating s Severity Warning Explanation The power supply is overheating If the problem persists the power supply will shut down Recommended Action Check that the power supply s air intake and outlet vents are not blocked Check that the switch is operating within the recommended ambient temperature range If the problem persists contact your support representative Otherwise no action is required REG_ACCESS_FAILED Cannot read s s registers Severity Error Explanation Failed to read a chip s registers This means either the chip is faulty or PciE access has failed Recommended Action Reset the linecard EOS User Manual 54 CHAPTER 2 SYSTEM MESSAGES REPEATER_COMM_ERROR Smbus access to repeater s s has fa
86. URCE INTERFACE UNSUPPORTED Source Interface spoofing requested with TCP Severity Warning Explanation Configuring logging source interface with a TCP host is not supported The source interface option will be ignored Recommended Action Please choose either UDP with source interface spoofing or TCP without source interface spoofing TIMESTAMP_FORMAT_ERROR Unknown timestamp format s was specified Severity Error Explanation Logging to may not function as expected because an unknown timestamp format was requested A defaulttimestamp format will be used intstead Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 70 CHAPTER 2 SYSTEM MESSAGES 2 39 LOOPBACK Messages MODE_CHANGE The loopback mode of interface s has changed to s Severity Info Explanation The system detected that the loopback mode of an interface has changed Recommended Action No action is required this message is for information only EOS User Manual 71 CHAPTER 2 SYSTEM MESSAGES 2 40 LOOPPROTECT Messages INTF_UP Bringing interface s back up after a loop was detected Severity Info Explanation Loop protection is configured to bring an interface back up after a period of time has elapsed Recommended Action No action is required this message is for information only RX_OTHER Received a malformed Loop Protection packet on interface s Severity
87. VLAN to VNI mapping d to d from s on VTI s has been ignored because VNI d has explicitly been mapped by a different VLAN d Severity Info Explanation A dynamic VLAN to VNI mapping has been ignored because the specified VNI has been mapped by a different VLAN through a CLI configuration Recommended Action Verify the dynamic VLAN to VNI mapping source or change the configured VLAN to VNI mapping If you are deliberately overriding the dynamic configuration no action is required DYNA_VLANVNI_CONFLICT_PEER Dynamic VLAN to VNI mapping d to d from s on VTI s has been ignored because it conflicts with other dynamic mappings d to d from s Severity Warning Explanation A dynamic VLAN to VNI mapping has been ignored because the specified VLAN has been dynami cally mapped to a different VNI or vice versa All conflicting mappings from dynamic sources have been ignored Recommended Action Verify the dynamic VLAN to VNI mapping sources or configure the intended mapping directly using the CLI configuration for the VTI DYNA_VLANVNLINVALID_CONFIG Dynamic VLAN to VNI mapping from s has been ignored a s VLAN config cannot be applied to s port Severity Warning Explanation A dynamic VLAN to VNI mapping has been ignored because we currently only support non zero VLAN mappings on trunk ports and zero VLAN mappings on access ports Recommended Action Verify the dynamic VLAN to VNI mapping source or change the switch port mode
88. Warning Explanation The agent is taking an excessive amount of time to reach steady state meaning declare itself operating consistently with its configuration and may be hung Recommended Action If the problem persists try killing the agent and letting ProcMgr restart it by dropping into bash mode using ps 1 to find the process and sending it SIGTERM or SIGKILL with kill 1 SOCKET_COMMAND ERROR Error s on command execution Severity Warning Explanation Unexpected error caught during the execution of the command Recommended Action No action is required this message is for information only SOCKET_INVALID_DESCRIPTOR Invalid socket request call Severity Warning Explanation Bad file descriptor received Recommended Action No action is required this message is for information only SWITCHOVER_DURING_INIT Agent s is exiting because switchover happened during initialization Severity Warning Explanation The agent is exiting because switchover just happened while it is still initializing It will restart and operate normally Recommended Action No action is required this message is for information only WARM AFTER EXCESSIVE DELAY Agent s warm after excessive delay Severity Warning Explanation The agent took an excessive amount of time to reach steady state but now it appears to be operating normally Recommended Action No action is required this message is for information only EOS User Manua
89. _INTF_VRF_ RESTORATION TIMEOUT Timed out waiting for vrf configuration to be applied on all interfaces Severity Warning Explanation This may result in some traffic disruption during ASU Recommended Action No action is required this message is for information only EOS User Manual 62 CHAPTER 2 SYSTEM MESSAGES 2 31 ISIS Messages ADJACENCY _ CHANGE Neighbor a state changed to s Severity Warning Explanation A neighbor s IS IS adjacency state has changed Recommended Action Usually no action is required This information can be useful for troubleshooting IS IS if the switch is not properly maintaining adjacency with one or more neighbors EOS User Manual 63 CHAPTER 2 SYSTEM MESSAGES 2 32 KERNELFIB Messages AGENT_RESTART KernelFib netlink socket has encountered ENOBUF d times Severity Notice Explanation Restarting the Agent Recommended Action No action is required this message is for information only THROTTLE_REDUCED KernelFib netlink socket has encountered ENOBUF Severity Notice Explanation Limiting the number of outstanding netlink requests to d Recommended Action No action is required this message is for information only EOS User Manual 64 CHAPTER 2 SYSTEM MESSAGES 2 33 LACP Messages ACTOR CHURN LACP Actor Churn Detected on s Severity Warning Explanation LACP could not come to a decision on an aggregate Recommended Action Investigate the LACP configurat
90. able to fix the problem System functionality will be severely limited until then Recommended Action Please see Knowledge Base article NN for instructions on how to manually program the FPGA FPGA UNRECOGNIZED The s FPGA image installed is not recognized by EOS Severity Error Explanation Fpgas provide logic and hardware level performance to many Arista switches The above chip is not currently recognized by the EOS operating system If the above chip is a Stratix V with customer specific functionality of the 7124FX family please contact your internal FPGA team Otherwise contact Arista customer support Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved FPGA UPGRADED Successfully upgraded the FPGA s to version d d Severity Info Explanation The above FPGA was successfully upgraded Recommended Action No action is required this message is for information only FPGA UPGRADEFAILED Failed to perform an upgrade of the FPGA s from version d d to version d d Severity Emergency Explanation The system could not perform an upgrade of an FPGA This may be due to a hardware or software failure System functionality will be severely limited Recommended Action Downgrading back to an earlier version of EOS may restore system functionality This is a serious error Contact your custom
91. active as primary with peer s and peer link s Severity Info Explanation MLAG protocol negotiation is complete with this chassis assuming the primary role Recommended Action No action is required this message is for information only STATE PRIMARY PEER LINK DOWN MLAG failed over to or remained at the primary state because the peer link s connected to peer s is down Severity Warning Explanation The configured peer link is down MLAG assumed the peer is dead and is now primary Recommended Action Check on the health of the other MLAG chassis STATE PRIMARY PEER LINK UP MLAG connection restored with peer s after the peer link s came back up MLAG will retain the primary role Severity Warning Explanation The configured peer link is up MLAG renegotiated with the peer and will remain primary Recommended Action No action is required this message is for information only STATE SECONDARY MLAG is active as secondary with peer s and peer link s Severity Info Explanation MLAG protocol negotiation is complete with this chassis assuming the secondary role Recommended Action No action is required this message is for information only STATE _ VERSION INCOMPATIBLE MLAG will not negotiate with peer s due to a version incompatibility Severity Error Explanation The current software image is incompatible with the peer s software image MLAG protocol negotiation will be unsuccessful Recommended Action Loa
92. age is for information only MAINT _UNIT STATE CHANGE Maintenance unit state changed for unit s Old State s New State s Severity Notice Explanation Maintenance unit state change log Recommended Action No action is required this message is for information only EOS User Manual 81 CHAPTER 2 SYSTEM MESSAGES 2 48 MROUTE Messages FASTDROP LIMIT EXCEEDED This device has reached the software limit for fastdrop entries Severity Warning Explanation Increase the number of allowed fastdrop entries or some rpf failures will continue coming to cpu Recommended Action No action is required this message is for information only FASTDROP LIMIT NO LONGER EXCEEDED This device is no longer at the software limit for fastdrop entries Severity Warning Explanation Rpf failures will install fastdrop entries and no longer come to cpu Recommended Action No action is required this message is for information only HW_RESOURCE FULL Hardware resources are insufficient to program all multicast routes s Severity Error Explanation The switch is unable to program all multicast routes because the multicast routing table exceeds available hardware resources Recommended Action To solve this issue reconfigure the network to reduce the size of the multicast routing table When the routing table size reduces the switch automatically programs any unprogrammed multicast routes in hardware HW_RESOURCE_NORMAL All multicast ro
93. al routing loops in the network Recommended Action To solve this issue one can shut and no shut interface vxlan If the problem still perisists reconfigure the interface vxlan configuration HW_FLOOD_RESOURCE_FULL Hardware resources are insufficient to program all vxlan multicast tunnels Severity Error Explanation The switch is unable to program all multicast tunnels due to insufficient hardware resources When the switch is unable to program multicast tunnels due to insufficient hardware resources it may drop certain packets in order to avoid potential routing loops in the network Recommended Action To solve this issue reduce the number of vxlan in the system followed by shut and no shut of interface vxlan HW_RESOURCE_CONFLICT VXLAN hardware resources are already in use for IP NAT Severity Error Explanation The switch encountered resource conflict between IP NAT and VXLAN features It will not be able to support both VXLAN and IP NAT at the same time Recommended Action To solve this issue remove both IP NAT and VXLAN on the switch and reconfigure only VXLAN Please contact your technical support representative if you need additional assistance INVALID_VARP_VTEP_ADDRESS VARP VTEP configuration has been ignored due to multiple secondary IP addresses on s Severity Error Explanation Configuration of VARP VTEP address is valid when there is only 1 secondary IP address on VXLAN source interface Recommended Action Confi
94. ame must contain only alphanu meric characters and It must begin and end with an alphanumeric character Recommended Action Configure a valid hostname CLI SCHEDULER ABORT Execution of scheduled CLI execution job s was aborted due to an error s Severity Warning Explanation Scheduled execution of a CLI command was aborted The output of that command has been stored in a log file on flash if max log files 0 Recommended Action Please try to execute the CLI command interactively to make sure it works fine CLI SCHEDULER FILESYSTEM FULL Execution of scheduled CLI execution job s was aborted due to flash filesystem being full Severity Warning Explanation Scheduled execution of a CLI command was aborted due to lack of space in flash filesystem Recommended Action Please delete unused files to free up space CLISCHEDULER_JOB_COMPLETED The scheduled CLI execution job s completed successfully s Severity Debug Explanation A scheduled CLI command successfully executed The output of that command is stored in a log file on flash if max log files 0 Recommended Action No action is required this message is for information only CLI SCHEDULER SKIP Execution of scheduled CLI execution job s was skipped Severity Notice Explanation Scheduled execution of a CLI command was skipped since previous execution for this job is yet to complete Recommended Action This may be due to
95. anation Some configuration changes require all switches to restart Recommended Action No action is required this message is for information only TABLE_MODE_CHANGE Operating mode for s table changed to d Severity Info Explanation Table operating mode changed Restarting Strata agent Recommended Action No action is required this message is for information only TABLE_MODE_CONFLICT_URPF uRPF is enabled in hardware Operating mode for s table cannot be changed to d Severity Info Explanation uRPF can only be configured when the table is in routing mode 2 or 4 and forwarding mode not 4 No other modes are supported with uRPF configuration Recommended Action No action is required this message is for information only TABLE _MODE_NO_CONFLICT_URPF uRPF is disabled in hardware Operating mode for s table changed to configured mode d Severity Info Explanation Reverting the operating mode of routing tcam forwarding table to configured value uRPF disabled in hardware and no longer causes any conflicts with the configured value Recommended Action No action is required this message is for information only TEMP_SENSOR INVALID Switch sensor d on s is reporting an invalid temperature f Severity Warning Explanation The specified temp sensor returned an invalid temperature reading This can happen intermittently but should not persist Recommended Action If the problem persists contact your support re
96. are Severity Error Explanation The switch was able to program all the ARP entries in hardware Recommended Action No action is required this message is for information only ROUTING FEATURE INCOMPATIBLE Egress IPv6 ACLs will not work while sharing next hops between IPv4 IPv6 Severity Error Explanation Egress IPv6 ACLs and next hop sharing are not compatible features Recommended Action Turn off adj sharing by issuing no ip hardware fib next hop sharing ROUTING GRE TUNNEL SIP RESOURCE FULL Hardware resources may be insufficient to program new nexthop group entries with new source IP addresses Severity Warning Explanation The switch may be unable to program new nexthop group entries due to insufficient source IP index hardware resources Recommended Action Configure your network to have new nexthop group entries reuse existing nexthop group source IP address configured in the switch ROUTING_GRE_TUNNEL_ SIP RESOURCE NORMAL New nexthop groups with new source IP addresses maybe programmed now in hardware Severity Warning Explanation The switch maybe able to program new nexthop group entries in hardware as source IP index resource is now available Recommended Action No action is required this message is for information only ROUTING GRE TUNNEL TTL RESOURCE FULL Hardware resources may be insufficient to program new nexthop group entries with new TTL values Severity Warning Explanation The switch may be
97. are resources with s ACLs Severity Info Explanation ACLs applied on routed ports will be uninstalled and installed again Recommended Action No action is required this message is for information only TTL1_CONFIG CONSISTENT The ttll trapping configuration on petraA and arad is now consistent Severity Warning Explanation Ttl 1 trapping behavior is no longer different Recommended Action No action is required this message is for information only TTL1_CONFIG INCONSISTENT The ttl 1 trapping configuration on petraA and arad is different Severity Warning Explanation Ttl 1 trapping behavior is different between the petraA and arad linecards Ingerss behavior will differ depending on the linecard packets ingerss on Recommended Action To solve this issue configure ttll trapping on petraA and arad as appropiate using no platform petraA ip trap ttl 1 and no platform arad ip trap ttl 1 VLAN IPV6_ACL_SHARING_MODE_CHANGE Change in resource sharing behavior for IPv6 ACLs applied on VLAN interfaces Severity Info Explanation SandAcl agent will restart to share unshare ACL hardware resources attached across multiple VLAN interfaces Recommended Action No action is required this message is for information only EOS User Manual 126 CHAPTER 2 SYSTEM MESSAGES 2 74 SANDTOPO Messages INIT FAILED SandTopo agent initialization failed due to s for the past s seconds Severity Error Explanation SandTopo ini
98. arning Explanation The forwarding ASIC only supports 32 unique storm control levels per chip Trying to configure more levels will not succeed Please reuse one of the already configured storm control levels for this interface Recommended Action No action is required this message is for information only MCAST_BOUNDARY_UNSUPPORTED_ERROR Multicast boundary is not supported in the current platform Severity Error Explanation A multicast boundary is configured but is currently not supported by the platform The configuration will be ignored Recommended Action To avoid seeing this error again remove all ip multicast boundary commands from your configuration file MCAST _PICASSO_NOT_READY Picasso memory is not ready in SandMcast Severity Error Explanation Picasso memory is not ready in SandMcast SandMcast is about to restart Recommended Action No action is required this message is for information only PETRA NOT QUIET s s are d but should be d Severity Debug Explanation Traffic activity has been detected while verifying Petra quiescence Recommended Action No action is required this message is for information only EOS User Manual 120 CHAPTER 2 SYSTEM MESSAGES POSSIBLE FABRIC ERROR Detected possible fabric error which was not resolved by resetting the switch fabric See show platform sand health for more details Severity Warning Explanation Errors occurred which were not resolved by
99. as in a FocalPoint switching ASIC The affected entry was repaired by ECC logic in the SRAM Traffic forwarding will not be affected by this error Recommended Action No action is required this message is for information only EOS User Manual A8 CHAPTER 2 SYSTEM MESSAGES FPV2_ PERR FATAL Fatal parity error occured in FocalPoint chip s s Severity Warning Explanation A fatal parity error occurred in a FocalPoint switching ASIC The FocalPointV2 agent restarted in order to recover from this error Recommended Action No action is required this message is for information only FPV2 PERR REPAIRED Parity error detected and repaired in FocalPoint chip s s count d Severity Info Explanation A parity error occurred in one of the tables in a FocalPoint switching ASIC The affected entry was repaired by rewriting it from the software cache Traffic forwarding may have been adversely affected for a few milliseconds Recommended Action No action is required this message is for information only FPV2_PERR_STATS_UNCORRECTABLE Uncorrectable parity error occurred in the statistics in FocalPoint chip Ps Ps Severity Warning Explanation An uncorrectable but non fatal parity error occurred in a FocalPoint switching ASIC Traffic forwarding will not be affected by this error Some statistics are no longer accurate To recover from this error restart the FocalPointV2 agent in a maintenance window Recommended Action
100. ast groups currently in use Severity Error Explanation An internal error has happened during an operation in the multicast routing table The internal state of the multicast table might be inconsistent Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 37 CHAPTER 2 SYSTEM MESSAGES MTUINDEXRESTORED Restored hardware resources for programming MTU on vlan d Severity Warning Explanation The vlan MTU value has been restored to its configured MTU value Recommended Action No action is required this message is for information only NOMTUINDEX Insufficient hardware resources for programming MTU on vlan d Severity Warning Explanation Insufficient hardware resources to program more than 16 distinct MTU values The vlan interface will revert back to a default MTU value of 1500 Recommended Action No action is required this message is for information only NO MORE SPANNING TREES Hardware resources are insufficient to create the number of requested spanning trees Severity Error Explanation The switch is unable to create the number of requested spanning trees due to insufficient hardware resources When the switch is unable to create enough spanning trees some VLANs may share a default spanning tree instead Recommended Action To solve this issue reconfigure the network to reduce the number of spanning trees required NO_STATIC_NAT_POLI
101. ch neighbors are eligible for adjacency or OSPF being explicitly disabled on the switch or its neighbors Recommended Action Depending on the reason and other network conditions this may or may not require action MAXLSALIMIT The max lsa limit of d has been reached for OSPF instance d shutting down for d minutes Jod of d Severity Error Explanation The number of LSAs in the OSPF routing system has reached the configured limit and the instance has been shut down It will be re enabled after the configured time in the hopes that the LSA flood is over Recommended Action Identify the system that is advertising excessive LSAs or raise this system s max lsa configuration MAXLSALIMIT_WARNING The max lsa limit of d has been reached for OSPF instance d Severity Error Explanation The number of LSAs in the OSPF routing system has reached the configured limit Recommended Action Identify the system that is advertising excessive LSAs or raise this system s max lsa configuration MAXLSARECOVER OSPF instance d has been re enabled after it was shut down due to reaching the max lsa limit Severity Error Explanation The instance is being re enabled after the max lsa ignore time Recommended Action No action is required The system is once again operating normally MAXLSASHUTDOWN The max lsa limit of d has been reached for OSPF instance d d times shutting down until reconfigured Severity Error Explanation The numbe
102. cket on s with BPDU guard enabled Disabling interface source mac s Severity Warning Explanation The switch received a Spanning Tree BPDU packet on a port which has BPDU guard enabled When the switch receives a BPDU packet on a BPDU guard enabled port it disables the port and drops the BPDU packet without further processing Recommended Action The switch received a Spanning Tree BPDU packet on a port which has BPDU guard enabled BPDU guard is configured directly for a port or globally configured for all portfast interfaces BPDU guard is typically enabled on portfast or edge ports that are connected to end hosts BPDU packets are not expected to be received on portfast ports by the switch and processing them can lead to problems in Spanning Tree So when the switch receives a BPDU packet on a port with BPDU guard enabled it disables the port To address the issue either remove the device attached to the port that is sending the BPDU packet or disable BPDU guard After resolving the issue the port can be enabled by issuing the shutdown command followed by no shutdown command in interface configuration mode BLOCK_RATELIMITER Exceeded BPDU rate limiter on s Severity Warning Explanation The switch received more Spanning Tree BPDUs than allowed by the configured maximum The port has been disabled to prevent a denial of service from excessive CPU usage Recommended Action The switch received more BPDUs on a given port than allowed
103. col match Severity Error Explanation The switch is unable to program this NAT rule Recommended Action Reconfigure your ACL to remove the protocol match ACL FILTER INVALID SOURCE ADDRESS NAT ACL s configured on interface s has invalid source address match s Severity Error Explanation The switch is unable to program this NAT rule Recommended Action Reconfigure your ACL to remove the source address match CONNLIMIT_DROP_RULES NAT active number of connections has exceeded the connection limit d installing iptable drop rules Severity Info Explanation Connection Limit is active and has reached its limit Recommended Action Configure ip nat translation max entries to a higher value if required CONNLIMIT_NO_DROP_RULES NAT active number of connections has reached below the connection limit low mark d deleting iptable drop rules Severity Info Explanation Connection Limit is active and active connections have reached low mark Recommended Action Run show ip nat translation max entries to see number of active connections and limit HW_RESOURCE_CONFLICT IP NAT hardware resources are already in use for Vxlan Severity Error Explanation The switch encountered resource conflict between IP NAT and Vxlan features It will not be able to support both Vxlan and IP NAT at the same time Recommended Action To solve this issue remove both IP NAT and Vxlan on the switch and reconfigure only IP NAT Please con
104. config file is installed correctly and is up to date PROCCFG_OPTION UNKNOWN Error config for s has unknown option s s Severity Error Explanation The specified config file contains an unknown config option The unknown option is listed Recommended Action Confirm that the package containing the file is correctly installed Plan not to be able to use this system until the problem is fixed PROCCFG_UNPARSEABLE Config file s can not be parsed The process configured in it will not be started Severity Info Explanation The process config file is not parseable This condition should be transient If it persists the system might be unstable Recommended Action A process config file was found to be unparseable This can occur while the system is being reconfigured e g packages are installed removed updated but should be transient If the message persists the sys tem might be unstable or some features might not work Find out why the process config file is expected but not there PROCESSES_ADOPTED ProcMer PID d adopted running processes s Severity Debug Explanation During a warm restart ProcMgr took over management of the listed process es already running Recommended Action No action required this message is informational only PROCESSES DECONFIGURED Processes no longer running under ProcMgr control s Severity Debug Explanation The specified processes have been removed from the set of proce
105. d because its config is bad Severity Error Explanation The specified process will not be started because its configuration is bad Recommended Action Confirm that the package containing the config file is correctly installed Plan not to be able to use this system until the problem is fixed PROCESS RESTART Restarting s immediately it had PID d Severity Info Explanation The specified process is being restarted immediately Recommended Action Keep an eye on the process if it restarts frequently figure out why PROCESS STARTED s starting with PID d PPID d execing s Severity Info Explanation The specified process is about to be started with the specified process ID PPID refers to the parent process s PID Recommended Action No action is required this message is for information only PROCESS_TERMINATED s PID d has terminated Severity Info Explanation The specified process has stopped running This may or may not be intentional Recommended Action No action is required this message is for information only PROGRAM_NOTEXECUTABLE Error Program for s s not executable but configured to run Severity Error Explanation A major feature might not work because the program that implements at least part of the feature can not be executed Recommended Action This is a serious error Confirm that the package containing the program is correctly installed Pla
106. d Action Configure all queriers on the network to use the same querier version EOS User Manual 59 CHAPTER 2 SYSTEM MESSAGES 2 28 INTF Messages MAX MTU EXCEEDED Configured mtu 9d exceeds the maximum mtu d for interface s Severity Warning Explanation This interface was configured with an mtu value that exceeds the maximum mtu supported for this type of interface Recommended Action Change the interface configuration to be consistent with the maximum supported mtu for this interface type RELOAD_HITLESS_CONFIG_TIMEOUT Time out waiting for config to be applied on all interfaces Severity Warning Explanation This may result in some traffic disruption during reload hitless Recommended Action No action is required this message is for information only SNMP_UNSUPPORTED Interface s is not supported by the Snmp agent Severity Error Explanation The software component that provides this type of interface does not properly support the Snmp agent so counters and other information for this interface will not be available via SNMP Recommended Action Contact your support representative EOS User Manual 60 CHAPTER 2 SYSTEM MESSAGES 2 29 IP6ROUTING Messages DAD FAILED IPv6 DAD failed on interface s for address s Severity Warning Explanation IPv6 Duplicate Address Detection has failed Recommended Action No action is required this message is for information only ECMP_ROUTE_MAX PATHS EXCEEDED
107. d a compatible software image on one of the peers Refer to the release notes for the list of compatible images TCAM_HW_RESOURCE_FULL Egress TCAM resources are insufficient to program MLAG peer link s Severity Error Explanation The switch is unable to program MLAG peer link configuration due to insufficient Egress TCAM resources Recommended Action Reconfigure your Egress ACLs to free up some resources for MLAG TCAM_HW_RESOURCE_RECOVERED MLAG peer link s is programmed Severity Error Explanation The switch was able to apply MLAG peer link configuration in Egress TCAM Recommended Action No action is required this message is for information only EOS User Manual 80 CHAPTER 2 SYSTEM MESSAGES 2 47 MMODE Messages INTF_PROFILE_CHANGE For interface s interface profile changed to s was s Severity Notice Explanation A different interface profile was picked based on precedence because the same same interface was part of multiple units Recommended Action No action is required this message is for information only MAINT_OP_WARNING Unit config is deleted for unit s The unit is still undergoing maintenance operation Severity Warning Explanation The maintenance status for the unit would be lost Recommended Action Please check the configuration MAINT STAGE PROGRESS Stage s s for unit s Severity Info Explanation Stage Progression logs Recommended Action No action is required this mess
108. d fan previously had an overcurrent condition but is now ok Recommended Action No action is required this message is for information only FAN SPEED FORCED All fan speeds have been forced to d percent because one or more of the following conditions have positive quanitites s Severity Notice Explanation System and PSU fan speeds forced to a set number Recommended Action No action is required this message is for information only FAN SPEED NORMAL All fan speeds have returned to normal operation Severity Notice Explanation Conditions that mandate using a set speed have subsided Recommended Action No action is required this message is for information only FAN SPEED OK The speed of s has recovered Severity Error Explanation The specified fan was previously too slow or too fast but is now ok Recommended Action No action is required this message is for information only FAN SPEED_TOO FAST The speed of s is faster than its configured value Severity Warning Explanation This may be caused by a defective fan Recommended Action Please try to re seat the fan If the problem persists replace the specified fan as soon as possible FAN_SPEED_TOO_SLOW The speed of s is slower than its configured value Severity Error Explanation This may be caused by a defective fan Recommended Action Please try to re seat the fan If the problem persists replace the specified fan as soon as possible INC
109. dary router MESSAGE_CRP_ZONE C RP advertisement received from s with Zone bit set Severity Notice Explanation Indicated C RP is a ZBR This message is logged in compliance to RFC 5059 Recommended Action If C RP is not a ZBR contact support This message is safe to ignore otherwise EOS User Manual 94 CHAPTER 2 SYSTEM MESSAGES 2 60 PORTSECURITY Messages PSECURE_ VIOLATION Security violation occurred caused by MAC address s on vlan d interface s Severity Critical Explanation The switch detected a violation of the MAC address table restrictions configured through the port security facility Recommended Action Review your network configuration and monitor the affected interface for unexpected MAC addresses PSECURE_VIOLATION_CLEARED Security violation previously reported on interface s has cleared Severity Notice Explanation The switch detected that a prior violation of the MAC address table restrictions configured through the port security facility has been lifted as the interface is now in compliance with port security requirements Recommended Action No action is required this message is for information only EOS User Manual 95 CHAPTER 2 SYSTEM MESSAGES 2 61 PREFIX Messages MROUTE_HW_RESOURCE FULL Hardware resources are insufficient to program all multicast prefix routes Severity Error Explanation To solve this issue reconfigure the network to reduce the size of the multicast prefix rou
110. dress s error count d Severity Warning Explanation The PCIe fabric integrity is unaffected Recommended Action If the problem persists contact your support representative Otherwise no action is required PCIE_SUPE_INIT COMM ERROR Smbus access to the supervisors Pcie switch s has failed Severity Error Explanation Software detected a problem communicating to a pcie switch in the system this may cause linecard or fabric cards to fail to power on Recommended Action If this problem persists please contact your support representative for assistance PCIE_SWITCH_EGRESS_CREDIT_TIMEOUT PCIE switch s detected egress credit timeout on port s Severity Info Explanation Possible hardware reset Recommended Action No action required this message if for information only PCIE_SWITCH_NO_UPSTREAM Unable to find upstream device for s Severity Error Explanation Possible hardware removal Recommended Action No action required this message if for information only PERR_CORRECTABLE s Severity Info Explanation A correctable parity error occurred in a switching ASIC The affected entry will be repaired by software Recommended Action No action is required this message is for information only PERR_CORRECTED s Severity Info Explanation Software corrected a parity error that occurred in a switching ASIC Normal traffic forwarding if affected by this error will resume Recommended Action No action i
111. dware resources needed for MLAG functionality are not ready Recommended Action Check the forwarding agent logs to find the details of the resources MLAG is waiting for STATE_INACTIVE LOCAL_CONFIG MLAG is inactive with peer s because the MLAG configuration changed Severity Info Explanation The MLAG configuration changed causing the peer relationship to end Recommended Action No action is required this message is for information only STATE_INACTIVE_LOCAL_INTERFACE_DOWN MLAG is inactive because the local interface s is down Severity Error Explanation The configured local VLAN interface is down The MLAG process is unable to accept connections from its peer Recommended Action Bring up the local interface STATE INACTIVE PEER CONFIG MLAG is inactive with peer s because the peer s MLAG configuration changed Severity Info Explanation The MLAG configuration of the peer changed causing the peer relationship to end Recommended Action No action is required this message is for information only STATE_INACTIVE_PEER_LINK_NOT_PRESENT MLAG is inactive because the peer link s connected to peer s is not present Severity Error Explanation The configured peer link is not present MLAG must become inactive because it cannot communicate with the peer Recommended Action Check the transceivers and linecards containing the peer link s EOS User Manual 79 CHAPTER 2 SYSTEM MESSAGES STATE_PRIMARY MLAG is
112. dware resources to add interface s as a mirror source Severity Warning Explanation Insufficent hardware resources are available to program interface s as a source to session s There is a maximum of d bidirectional sources or d unidirectional sources and this limit has been exceeded As a result traffic on this interface shall not be mirrored Recommended Action Use fewer mirror sources across the switch MIRROR_SOURCE_RESOURCES_NORMAL All mirror sources are programmed in hardware Severity Warning Explanation The switch was able to program all sources in hardware Recommended Action Normal mirroring has resumed MULTICASTGROUPCLEAR The condition of having insufficient hardware resources for programming a forwarding entry for the multicast group s in VLAN d has cleared Severity Warning Explanation Traffic sent to this multicast group will be forwarded only to ports belonging to this group Recommended Action Okay to use this IP multicast group EOS User Manual 19 CHAPTER 2 SYSTEM MESSAGES NOMACTABLEENTRIES Unable to program mac table entry for MAC address s in VLAN d due to hardware resource exhaustion Severity Warning Explanation The specified MAC address could not be programmed into the switching ASIC due to hash collisions in a bucket Packets destined to the address will be flooded Recommended Action Reduce the number of host table entries that need to be programmed into the switching ASIC One or more
113. e Otherwise no action is required CONNECT FAILED Failed to connect to vCenter s Severity Error Explanation This error indicates that the VMware VDS agent could not connect to vCenter Recommended Action Check the configured URL in vmware vswitch session configuration and verify network connectivity to vCenter LOGIN_ERROR Login to vCenter failed s Severity Error Explanation This error indicates that the VM Tracer agent could not login to vCenter using the configured username and password Recommended Action Check the configured credentials in the VMware vSwitch session configuration RPC_FAULT The RPC s failed Severity Error Explanation This error indicates that the VM Tracer agent could not complete the RPC call to vCenter Recommended Action If the problem persists contact your support representative Otherwise no action is required VCENTER_CONNECTED VmTracer agent successfully connected to vCenter s Severity Info Explanation The VmTracer agent was successfully able to establish connection with the vCenter Recommended Action No action is required this message is for information only VMOTION END VM s migrated to s Severity Info Explanation Vmotion completed on the VM Recommended Action No action is required this message is for information only VMOTION STARTED VM s in vmotion from s to s Severity Info Explanation Vmotion triggered on the VM Recommended Action No action
114. e is for information only EOS User Manual 146 CHAPTER 2 SYSTEM MESSAGES LOGMSG_EMRG Message from s on s s s Severity Emergency Explanation As a result of send log command from the CLI Recommended Action No action is required this message is for information only LOGMSG_ERR Message from s on s s s Severity Error Explanation As a result of send log command from the CLI Recommended Action No action is required this message is for information only LOGMSG _INFO Message from s on s s s Severity Info Explanation As a result of send log command from the CLI Recommended Action No action is required this message is for information only LOGMSG_NOTICE Message from s on s s s Severity Notice Explanation As a result of send log command from the CLI Recommended Action No action is required this message is for information only LOGMSG_WARN Message from s on s s s Severity Warning Explanation As a result of send log command from the CLI Recommended Action No action is required this message is for information only PLUGIN_LOAD FAILED Unable to load plugin s s Severity Error Explanation A plugin could not be loaded The functionality provided by the plugin is not available Please check the plugin and restart the agent if necessary Recommended Action If the problem persists contact your support representative Ot
115. e the same querier version EOS User Manual 44 CHAPTER 2 SYSTEM MESSAGES 2 25 HARDWARE Messages AHWAHNEE PICASSO INIT FAILED Ahwahnee picasso init failed Severity Warning Explanation Setting up of picasso pcie BAR on ahwahnee supe has failed Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved ALTA POWER RAILS _ADJFAILED Failed to perform FM6000 power rail adjustment Severity Warning Explanation The system could not perform an adjustment of FM6000 power rails Recommended Action Rebooting the system may solve the problem This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved ALTA POWER RAILS ADJUSTED Successfully adjusted FM6000 power rails Severity Info Explanation Voltage on FM6000 power rails was adjusted to its optimal value Recommended Action No action is required this message is for information only CARD_BAD_INPUT_VOLTAGE s supply voltage is incorrect voltage is s Severity Error Explanation Software detected that the card has a power supply problem Recommended Action If the problem persists contact your support representative Otherwise no action is required CARD_EJECTOR_CLOSED Card s s ejector handle is now closed Se
116. ed Action No action is required this message is for information only BFD EVENT s Grp d Taking over s and transitioning to master Severity Notice Explanation The VRRP router is transitioning to master because the BFD session goes down Recommended Action No action is required this message is for information only BFD MISMATCH s Grp d Bfd peer s does not match master s address s Severity Warning Explanation The Bfd peer configured in Cli does not match the master s Ip address in advertisement Recommended Action No action is required this message is for information only CONFIGURED ADDRESSES COMPATIBLE VRRP configuration is now compatible with hardware Severity Error Explanation VRRP configuration is now compatible with hardware Recommended Action No action is required this message is for information only CONFIGURED_ADDRESSES_ INCOMPATIBLE Configured VRRP groups result in the following incompatible addresses s Addresses may only vary in the lower 3 bits Severity Error Explanation VRRP MAC addresses may only differ in the lower 3 bits Recommended Action Remove the incompatible VRRP configuration EOS User Manual 159 CHAPTER 2 SYSTEM MESSAGES INCOMPATIBLE_WITH_MLAG_PEER_MAC Ignoring VRRP MAC address s in s because Mlag peerMac is configured Severity Error Explanation VRRP and Mlag peerMac cannot be configured at the same time Recommended Action Remove either the VRRP
117. ed Action No action is required this message is for information only SHUTDOWN SIGKILLPROC ProcMgr shutting down stopping s PID d with SIGKILL Severity Info Explanation ProcMgr will deliver SIGKILL to the listed processes to allow it to shutdown gracefully Recommended Action No action is required this message is for information only TERMINATE PROCESS SIGKILL Heartbeats from s PID d missing for s secs terminating it with SIGKILL Severity Info Explanation ProcMgr is terminating the specified process because it is not behaving as expected has been reconfigured or has been configured to stop Recommended Action This message is expected when the system is being reconfigured If this message appears frequently when the system is not being reconfigured there may be something wrong with the process TERMINATE _PROCESS_SIGQUIT Heartbeats from s PID d missing for s secs terminating it with SIGQUIT Process kernel stack is s Syscall is s Severity Warning Explanation ProcMgr is terminating the specified process because it has detected that the process is not behaving as expected heartbeats from the process are unexpectedly missing Recommended Action Keep an eye on the process if this happens frequently there may be something wrong with the process TERMINATE_RUNNING PROCESS Terminating deconfigured reconfigured process s PID d Severity Info Explanation
118. edundancy Severity Warning Explanation A fabric chip has been taken offline due to persistent fabric errors The fabric card may need to be replaced Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved FPGA PARITY ERROR Corrino memory parity errors occurred in s Severity Error Explanation Corrino memory parity errors have been detected Recommended Action If the problem persists contact your support representative Otherwise no action is required INGRESS_RESET Reset ingress blocks of switch chip s Severity Warning Explanation Software re initialized the ingress blocks of the chip causing 50ms of traffic loss Recommended Action No action is required this message is for information only INIT_FAILED Initialization of s switch asics failed Severity Error Explanation The initialization of the switch asics on this card failed This could be an intermittent problem and it will work next time or it could be bad hardware Recommended Action If the problem persists contact your support representative Otherwise no action is required INIT_SUCCEEDED Initialization of s switch asics succeeded Severity Info Explanation The switch asics have been successfully initialized and are operating normally Recommended Action No action is required this message is for i
119. eiving PVST BPDUs with inconsistent root information so it has been set to inconsistent to avoid STP loops Recommended Action The interface will exit the PVST inconsistent state if it begins receiving PVST BPDUs with consistent root information or interface is connected to MST region or MST PVST interoperation is disabled MSTPVST BORDER INCONSISTENT EXIT Interface s is exiting the PVST inconsistent state Severity Warning Explanation The given interface was previously in PVST inconsistent state in order to avoid STP loops This state has been cleared and normal operation has resumed Recommended Action The port exited the PVST inconsistent state either because it began receiving PVST BP DUs with consistent root information or interface is connected to MST region or MST PVST interoperation is disabled MSTP_REGION BORDER CLEARED MSTP region border cleared on s Severity Info Explanation The given interface is no longer a MSTP border Recommended Action No action is required this message is for information only MSTP_REGION_BORDER_DETECTED MSTP region border detected on s Severity Info Explanation The given interface is a MSTP border facing another region Recommended Action No action is required this message is for information only OVERRIDE Spanning tree is disabled port state is controlled by s Severity Info Explanation The spanning tree protocol is disabled and port state is now controlled by the specified
120. em until the problem is fixed CONFIG UNREADABLE Fatal error cfg file s is not readable Severity Emergency Explanation The system is unusable because the ProcMgr configuration file exists but can not be read Recommended Action This is a serious error Confirm that the package containing ProcMgr is correctly installed Plan not to be able to use this system until the problem is fixed EXECFAILED Error s is no longer running exec returned unexpectedly Severity Emergency Explanation The specified process failed to start Recommended Action Plan not to be able to use this system until the problem has been fixed FINALSHUTDOWN Final shutdown ProcMegr d and all related processes stopped Severity Info Explanation This is the last message from ProcMgr before final shutdown Recommended Action No action is required this message is for information only FORKFAILED Fatal error unable to start s s Severity Emergency Explanation The specified process could not be started The reason for the failure is specified in the message Recommended Action Plan not to be able to use this system until the problem has been fixed HEARTBEATFILEMISSING Heartbeat file of s PID d is missing Severity Info Explanation The heatbeat file of the specified process is missingProcMgr will stop the process and will restart it if applicable Recommended Action Keep an eye on the message MASTER
121. ended Action Reconfigure your ACLs to reduce the size and or complexity of the ACL NOSESSIONGROUPS Insufficient hardware resources to allocate mirror session s The current limit on the number of mirror sessions is d Severity Warning Explanation It is not possible to program the mirror session in hardware due to lack of hardware resources Recommended Action Use fewer mirror sessions SESSION_LIMIT_EXCEEDED Monitor session s is inactive because it exceeds the maximum number of supported monitor sessions d Severity Warning Explanation When the maximum number of supported monitor sessions is exceeded newly created monitor sessions are not programmed into hardware Recommended Action Reduce the number of configured monitor sessions TIMESTAMP_WITH_TRUNCATE_NOTSUPPORTED Timestamping on interface s s does not work with truncation configured on mirror session s Severity Warning Explanation The trunction of the mirrored packet will cause the timestamp to be lost Recommended Action Disable truncation on mirror session VOQ_NOT_DRAINED VOQ d on Fap s for mirror destination s is not draining Queue size is d bytes Severity Error Explanation Egress port queue is in inconsistent state This can lead to stuck port resulting in packet drops The port is unusable until the forwarding agent restarts Recommended Action If the problem persists contact your support representative Otherwise no action is required
122. ent to program IP source guard entries s Severity Error Explanation The switch is unable to program IP source guard entries due to insufficient ingress TCAM resources As a result IP traffic is not properly filtered s Recommended Action Free up some ingress TCAM resources for IP source guard One or more of the following steps might be helpful 1 Remove unused IP source binding entries 2 Reconfigure other features that use ingress TCAMs IPSG_HW_RESOURCE_RECOVERED All IP source guard entries on unit d are programmed in TCAM Severity Error Explanation The switch was able to install IP source guard entries to the ingress TCAM Recommended Action IP source guard configuration on unit d works in hardware EOS User Manual 128 CHAPTER 2 SYSTEM MESSAGES SSH_CLIENT_CONNECTING s is connecting a SSH session from the switch to s O s s Severity Info Explanation A person logged into the switch began a SSH session to an external server Recommended Action No action is required this message is for information only SSH_CLIENT_DISCONNECTED s disconnected the SSH session from the switch to s s d Severity Info Explanation The SSH session from the switch to the remote server is now over Recommended Action No action is required this message is for information only SSH_TUNNEL_ALGORITHM_MISMATCH SSH tunnel s was unable to connect to the configured remote server due to not finding a matching s Severity Error
123. er support representative with the contents of the message and plan to be unable to use the system until the problem has been solved FPGA_UPGRADEINTERRUPTED A previous attempt to upgrade the FPGA s was interrupted Severity Info Explanation The system detected that a previous attempt to upgrade the given FPGA was interrupted before the upgrade completed This could be because the switch lost power while upgrading the FPGA Recommended Action No action is required this message is for information only FPGA_UPGRADEMISSINGREVISION A previous attempt to upgrade the FPGA s could not proceed because the system was given a missing or corrupt FPGA image file s Severity Error Explanation The system detected that the FPGA image file supplied to it was either missing or corrupt Hence it could not read the revision number for the supplied image Recommended Action Please ensure that a valid image file is supplied for the upgrade FPGA_VALID The s FPGA is currently being read by EOS Severity Notice Explanation Fpgas provide logic to and hardware level performance to many Arista switches The above chip has been programmed successfully and is recognized by the EOS operating system Recommended Action No action is required this message is for information only FPV2 PERR_CORRECTED Parity error repaired by ECC logic in FocalPoint chip s s count d Severity Info Explanation A parity error occured in one of the SRAM are
124. er the last d seconds Severity Warning Explanation The switch detected out of order probe s Recommended Action Check network links and probe reception on neighboring devices to determine the cause of probe misordering PROBE_DUPLICATE_ON_STREAM Reachability Monitor detected probe duplicate d probe s duplicates so far on the following stream s Severity Warning Explanation The switch detected duplicate probe s on this probe stream Recommended Action Check network links and probe reception on neighboring devices to determine the cause of probe duplication PROBE_LOST_ON_STREAM Reachability Monitor detected probe loss d probes lost so far on the following stream s Severity Warning Explanation The switch detected lost probe s on this probe stream Recommended Action Check network links and probe reception on neighboring devices to determine the cause of probe loss PROBE_MISORDERED_ON_STREAM Reachability Monitor detected probe misordering d probe s misor dered so far on the following stream s Severity Warning Explanation The switch detected out of order probe s on this probe stream Recommended Action Check network links and probe reception on neighboring devices to determine the cause of probe misordering EOS User Manual 110 CHAPTER 2 SYSTEM MESSAGES 2 69 REDUNDANCY Messages CONFIG SYNC s synchronized from Supervisor d active to Supervisor d standby Severity Info Explana
125. erating SSH host keys Severity Info Explanation Software has noticed that the SSH host keys on this system are associated with the mac address of a different system This can happen in a modular system when a supervisor is moved to a different chassis New SSH host keys have been generated for the system Recommended Action No action is required this message is for information only SYSTEM_RESTARTED System restarted Severity Notice Explanation The system has restarted Recommended Action No action is required this message is for information only SYSTEM WARMUP FAILED System warmup after cli configuration by s on s s failed Severity Notice Explanation The system is taking a long time to warm up after the last configuration request from the Cli This may mean an unusually large configuration change was requested from the Cli which resulted in prolonged processing by the switching software Recommended Action No action is needed However avoid loading the switch with large amount of configuration changes in quick succession EOS User Manual 148 CHAPTER 2 SYSTEM MESSAGES 2 82 SYSDB Messages STARTUP_CONFIG ERROR Unable to load initial configuration code d Severity Emergency Explanation Error occurred while loading the initial system configuration Exiting Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unab
126. eration will continue to be retried Recommended Action No action is required this message is for information only EOS User Manual 112 CHAPTER 2 SYSTEM MESSAGES 2 70 RIB Messages IGP_CONVERGED IGP protocols in VRF s have converged and their routes are in FIB Severity Notice Explanation IGP protocols say OSPF have converged and routes are now available in FIB Besides IGP protocols Rib agent is also done with initial processing of all connected and static routes Recommended Action No action is required this message is for information only MAX PATHS EXCEEDED Route s has too many paths using only d Severity Error Explanation The RIB agent has attempted to allocate an ECMP route with more paths than the maximum supported by the hardware The extra paths have been discarded from the route Recommended Action No action is required this message is for information only ROUTE_READY Routes in VRF s are ready and available in FIB Severity Notice Explanation With routes now being ready in FIB forwarding agent will start syncing them down to hardware without fear of purging any routes had router undergone graceful restart say Rib restart hitless system upgrade Recommended Action No action is required this message is for information only ROUTE READY TIMEOUT Route types in VRF s that are not converged s Severity Notice Explanation Rib agent timed out waiting for one or more routing protoc
127. es are insufficient to program all IP tunnels Severity Error Explanation The switch is unable to program all tunnels due to insufficient hardware resources When the switch is unable to program tunnels due to insufficient hardware resources it may drop certain packets in order to avoid potential routing loops in the network The switch encountered this issue because the number of tunnel destinations peering with this switch exceeds the size of the hardware tunnel table Recommended Action To solve this issue reconfigure the network to reduce the number of tunnel destination peering When the tunnel table size reduces the switch automatically programs any unprogrammed tunnels in hardware tunnel table EOS User Manual 114 CHAPTER 2 SYSTEM MESSAGES IPTUNNEL_HW_RESOURCE_NORMAL All IP tunnels are programmed in hardware Severity Error Explanation The switch was able to program all the tunnels in the tunnel table in hardware and normal hardware routing has resumed Recommended Action No action is required this message is for information only MAX PATHS EXCEEDED Number of paths 9d for adj d higher than max supported value d Severity Error Explanation The system is trying to allocate an ecmp route with more paths than the maximum allowed by the hardware The route will be programmed to to use only the maximum allowed Recommended Action No action is required this message is for information only MCAST_REPLICATIO
128. ess stream table Severity Warning Explanation The number of streams received is appropriate for size of ingress stream table Recommended Action No action is required this message is for information only NEW INGRESS STREAM Reachability Monitor detected a new probe stream s Severity Info Explanation The switch detected a probe stream from which probes were not previously continually received Recommended Action No action is required this message is for information only NEW INGRESS STREAMS Reachability Monitor detected d new probe stream s in the last d seconds Severity Info Explanation The switch detected new probe stream s Recommended Action No action is required this message is for information only PROBES DUPLICATED Reachability Monitor detected d probe s duplicated for all probe streams over the last d seconds Severity Warning Explanation The switch detected duplicated probe s Recommended Action Check network links and probe reception on neighboring devices to determine the cause of probe duplication PROBES LOST Reachability Monitor detected d probe s lost for all probe streams over the last d seconds Severity Warning Explanation The switch detected lost probe s Recommended Action Check network links and probe reception on neighboring devices to determine the cause of probe loss PROBES _MISORDERED Reachability Monitor detected d probe s misordered for all probe streams ov
129. essage is for information only FP_PERR_CUMULATIVE Cumulative parity error occured in FocalPoint chip s s count d Severity Warning Explanation A parity error occurred in an SRAM in a FocalPoint switching ASIC The affected segment 512 bytes of packet memory has been disabled Recommended Action No immediate action is required Reboot the switch during the next scheduled maintenance window to recover the lost memory FP_PERR_FATAL Fatal parity error occured in FocalPoint chip s s Severity Warning Explanation A fatal parity error occurred in a FocalPoint switching ASIC The FocalPoint agent restarted in order to recover from this error Recommended Action No action is required this message is for information only EOS User Manual 49 CHAPTER 2 SYSTEM MESSAGES FP_PERR_REPAIRED Parity error detected and repaired in FocalPoint chip s s count d Severity Info Explanation A parity error occurred in one of the tables in a FocalPoint switching ASIC The affected entry was repaired by rewriting it from the software cache Traffic forwarding may have been adversely affected for a few milliseconds Recommended Action No action is required this message is for information only FP PERR TRANSIENT Transient parity error occured in FocalPoint chip s s count d Severity Info Explanation A parity error occurred while forwarding a frame in a FocalPoint switching ASIC The frame will have been drop
130. everity Emergency Explanation The system was overheating but has now returned to a normal operating temperature Recommended Action No action is required this message is for information only SYSTEM AIRFLOW DIRECTION ELECTED The correct airflow for the system is s Severity Notice Explanation Correct system airflow either found for first time or changed Recommended Action No action is required this message is for information only SYSTEM FANS MISSING FAILED d system fan s missing or failed Severity Emergency Explanation The specified number of system fans are missing from the system Recommended Action Insert the missing fans and replace the failed fans TEMPSENSORFAILED s failure detected Severity Error Explanation The specified temp sensor has failed Recommended Action If the problem persists contact your support representative Otherwise no action is required TEMPSENSORINVALID s is reporting an invalid temperature Severity Error Explanation The specified temp sensor returned an invalid temperature reading This can happen intermittently but should not persist Recommended Action If the problem persists contact your support representative Otherwise no action is required TEMPSENSOROK s has recovered Severity Error Explanation The specified temp sensor had previously failed but is now ok Recommended Action No action is required this message is for information only TEMPSENSOR_
131. everity Warning Explanation The spanning tree message age timer expired because no BPDUs were received from the designated bridge Because this condition could be caused by an unidirectional link failure the interface is put into blocking state and marked as loop guard inconsistent in order to prevent possible loops from being created Recommended Action Use the show spanning tree inconsistentports command to review the list of interfaces with loop guard inconsistencies Determine why devices that are connected to the listed ports are not sending BPDUs One reason could be that they do not run the Spanning Tree Protocol in this case you should disable loop guard in the inconsistent interfaces or start the Spanning Tree Protocol on the other side of the links depending on the context Another reason could be a failure in the cable If the link has a failure that makes it unidirectional you can transmit but you cannot receive you should replace the old cable with a new cable LOOPGUARD_CONFIG_CHANGE Loop guard s on port s Severity Info Explanation There was a change in the spanning tree loop guard configuration for the listed interface When enabled the interface will be put into blocking state and marked as loop guard inconsistent when the message age timer expires because no BPDUs were received from the designated bridge This feature is used to detect unidirectional links Recommended Action Verify that this is the desired configurati
132. f routes being shared by your BGP peers If the number of routes is reasonable then increase the maximum routes limit After taking either of these actions issue the clear ip bgp peer command to reset the BGP peer connection IF_MAXROUTESRECOVER Peer s has managed to drop below its configured maximum total number of routes Yd routing information is no longer being lost Severity Notice Explanation The number of routes from this BGP peer is now below the limit and we are exchanging routing information with the peer again Recommended Action Determine why the number of shared routes exceeded maximum routes limit in the first place IF MAXROUTESRESTART Peer s has exceeded its configured maximum total number of routes d In idle state will restart in d minutes Severity Notice Explanation BGP has received more routes than it is configured to handle from this BGP peer Routing information may be incomplete and may get further out of date Route information is no longer being exchanged with peer so no route deletions or additions will occur until the peer connection is restarted Recommended Action Determine whether the number of shared BGP routes is reasonable If not then try to reduce the number of routes being shared by your BGP peers If the number of routes is reasonable then increase the maximum routes limit Until you take one of these actions the BGP peer connection will continue to get into this state and wil
133. face is not supported Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 58 CHAPTER 2 SYSTEM MESSAGES 2 27 IGMPSNOOPING Messages GROUP LIMIT EXCEEDED IGMP group limit of d groups exceeded in VLAN d Severity Warning Explanation The switch detected that the number of IGMP groups joined by hosts in the specified VLAN exceeds the configured number allowed for this VLAN Recommended Action Increase the max groups limit for the VLAN or configure the hosts in the VLAN to join fewer groups GROUP_LIMIT_NO_LONGER_EXCEEDED IGMP group limit of d groups no longer exceeded in VLAN d Severity Warning Explanation The switch detected that the number of IGMP groups joined by hosts in the specified VLAN no longer exceeds the VLAN s configured max groups limit Recommended Action No action is required this message is for information only GROUP_LIMIT_NO LONGER EXCEEDED NO LIMIT IGMP group limit no longer exceeded in VLAN d Severity Warning Explanation The switch detected that the number of IGMP groups joined by hosts in the specified VLAN no longer exceeds the VLAN s previously configured max groups limit Currently no limit is configured Recommended Action No action is required this message is for information only HW_RESOURCE_FULL Hardware resources are insufficient to program all IgmpSnooping groups s Severity Error Explanation
134. failed While the power supply has recovered the problem should be fixed as soon as possible to avoid potential downtime in the future EOS User Manual 103 CHAPTER 2 SYSTEM MESSAGES 2 65 QOS Messages COPP_ HW RESOURCE FULL Insufficient TCAM resources to program the policy map s Severity Error Explanation The switch is unable to program QoS CoPP configuration due to insufficient TCAM resources Recommended Action Reduce number of ACL rules in policy map classes or reconfigure your ACLs to free some resources for CoPP COPP HW RESOURCE NORMAL Policy map s is programmed in TCAM Severity Error Explanation The switch was able to program entire CoPP configuration in the TCAM Recommended Action No action is required this message is for information only ECN GLOBAL HW FULL Hardware resources insufficient to program global buffer ECN Severity Error Explanation The switch is unable to program ECN configuration due to insufficient Hardware resources Recommended Action No action is required this message is for information only ECN QUEUE HW FULL Hardware resources insufficient to program tx queue ECN on queue s for port s Severity Error Explanation The switch is unable to program ECN configuration due to insufficient Hardware resources Recommended Action No action is required this message is for information only ECN_TCAM FULL TCAM resources are insufficient to program TCAM to avoid nonECT drops Seve
135. feature Recommended Action No action is required this message is for information only ROOTCHANGE Root changed for instance s new root interface is s new root bridge mac address is s s Severity Info Explanation The spanning tree root bridge of the given instance changed to the given new value Recommended Action No action is required this message is for information only ROOTGUARD BLOCK Root guard blocking port s on s Severity Warning Explanation A BPDU was received on the listed interface that advertised a spanning tree root bridge that was superior to the one already in use The interface is put into a blocking state and marked as root guard inconsistent to prevent a suboptimal spanning tree topology from forming Recommended Action Enter the show spanning tree inconsistentports command to review the list of interfaces with root guard inconsistencies Determine why devices that are connected to the listed ports are sending BPDUs with a superior root bridge and then take action to prevent further occurrences Once the invalid BPDUs have been stopped the interfaces automatically recover and resume normal operation By looking at the configuration ensure that it is appropriate to enable root guard on the interface ROOTGUARD_CONFIG_CHANGE Root guard s on port s Severity Info Explanation There was a change in the spanning tree root guard configuration for the listed interface If root guard is enabled any BPDU t
136. fied number of fabric cards are missing from the system Recommended Action Insert the missing fabric cards FANFAILED s failure detected Severity Error Explanation The specified fan has failed or been removed Recommended Action Replace the specified fan as soon as possible FANOK s has recovered Severity Error Explanation The specified fan was previously missing or had previously failed but is now ok Recommended Action No action is required this message is for information only EOS User Manual 23 CHAPTER 2 SYSTEM MESSAGES FAN AIRFLOW DIRECTION INCORRECT Airflow of s is incompatible with the system airflow Severity Emergency Explanation The specified fan s airflow is opposite to the correct system airflow Recommended Action Replace the fan with a fan that has correct airflow FAN_AIRFLOW_DIRECTION_ OK Airflow of s has been restored to compatible with the system airflow Severity Emergency Explanation The specified fan s airflow was previously wrong but is now correct Recommended Action No action is required this message is for information only FAN FAULT s logged a fan fault Severity Error Explanation This may be caused by a defective fan or an overcurrent condition Recommended Action Please try to re seat the fan If the problem persists replace the specified fan as soon as possible FAN FAULT OK s has recovered from a fan fault Severity Error Explanation The specifie
137. fo Explanation Controller main connection is active Recommended Action No action is required this message is for information only CONTROLLER DISCONNECT Controller s role s disconnected Severity Info Explanation Controller main connection is inactive Recommended Action No action is required this message is for information only FORWARDING PIPELINE_CHANGE OpenFlow Forwarding Pipeline changed from s to s Severity Info Explanation OpenFlow Forwarding Pipeline has been changed Recommended Action No action is required this message is for information only TABLE_PROFILE_CHANGE OpenFlow Table Profile changed from s to s Severity Info Explanation OpenFlow Table Profile has been changed Recommended Action No action is required this message is for information only EOS User Manual 89 CHAPTER 2 SYSTEM MESSAGES 2 55 OSPF Messages ADJACENCY ESTABLISHED NGB a interface a adjacency established Severity Warning Explanation The switch has finished the OSPF handshaking process with a neighboring switch and now sees it as adjacent Recommended Action No action is required this message is for information only ADJACENCY _TEARDOWN NGB a interface a adjacency dropped s state was s Severity Warning Explanation The switch has removed a neighbor s adjacent status for the given reason There are many possible causes including invalid data received from a neighbor a change in whi
138. ges TRANSIENT DOWN Line protocol on Interface s briefly went down d times since last logged Severity Notice Explanation The link layer connection on the given interface went down very briefly This is a symptom of an unreliable physical connection Check the physical connection e g cable between the devices Recommended Action If the problem persists contact your support representative Otherwise no action is required UPDOWN Line protocol on Interface s changed state to s Severity Notice Explanation The link layer connection on the given interface has come up or down If it is not up then communica tion with our link partner is not possible Recommended Action If the connection has gone down unexpectedly check the physical connection e g cable between the devices and the configuration of the link on both ends EOS User Manual 68 CHAPTER 2 SYSTEM MESSAGES 2 37 LLDP Messages NEIGHBOR GONE Received a shutdown frame from LLDP neighbor with chassisId s and portld s on interface Ps Severity Notice Explanation An LLDP neighbor was deleted from the neighbor table since an LLDPDU with a TTL of 0 was received from that neighbor Recommended Action No action is required this message is for information only NEIGHBOR NEW LLDP neighbor with chassisId s and portId s added on interface s Severity Notice Explanation A new LLDP neighbor was added to the neighbor table Recommended Action No actio
139. gure only 1 secondary IP address on VXLAN source interface LEARN_NOTALLOWED Received VXLAN packet from VTEP s for VNI s but that VTEP is not part of the set of trusted sources for dataplane learning Severity Warning Explanation The switch is only doing VXLAN dataplane learning from VTEPs that have been configured as trusted using vxlan learn Recommended Action Please ensure that the VTEP configuration is consistent across all the switches That might imply adding this VTEP to the vxlan learn list ROUTING MULTICAST INCOMPATIBLE VXLAN routing is not supported if flood replication mode is multicast Severity Error Explanation The switch encountered a VXLAN enabled VLAN with SVI configured while flood replication mode for the VTI is configured as multicast Recommended Action To solve this issue remove multicast flood replication configuration on VTI and configure flood replication mode as headend or remove the SVI configuration on the VLAN Please contact your technical support representative if you need additional assistance ROUTING _VNI_LENGTH UNSUPPORTED VXLAN routing is not supported on a VLAN with VNI greater than 65535 Severity Error Explanation The switch encountered a VXLAN enabled VLAN with SVI configured and its mapped VNI value is greater than 65535 or 16 bits Recommended Action To solve this issue remove the invalid VNI mapping on the SVI VLAN and reconfigure new VLAN to VNI mapping with vni j 6
140. hat is received on the interface that advertises a superior spanning tree root bridge to the one that is already in use will cause the interface to be put into blocking state and marked as root guard inconsistent Recommended Action Verify that this is the correct configuration for the listed interface If this is not the correct configuration change the configuration to one that is appropriate for the interface EOS User Manual 135 CHAPTER 2 SYSTEM MESSAGES ROOTGUARD_UNBLOCK Root guard unblocking port s on s Severity Warning Explanation The listed interface is no longer receiving BPDUs that are advertising a superior root bridge The root guard inconsistency is cleared for the interface and then is taken out of the blocking state 1f appropriate Recommended Action This is an informational message only no action is required RXDOT1QPKT A non standard IEEE BPDU packet was received and discarded on interface s source mac s The packet was inconsistent with the IEEE standard because it was encapsulated with an 802 10 header Severity Warning Explanation The switch received an 802 1Q tagged Spanning Tree BPDU packet Arista Networks switches drop these packets without further processing so the protocol may not function properly on the receiving interface To fix this problem reconfigure the sending switch to transmit its Spanning Tree BPDU packets untagged or configure 12 protocol encapsulation dotlq vlan x on Arista switc
141. herwise no action is required PORT ID ERROR Unable to allocate a port ID for interface s Severity Alert Explanation No unallocated port ID s are available Recommended Action No action is required this message is for information only RESTART SERVICE Service s is not running Attempting to restart it Severity Warning Explanation Periodic health monitoring found that the said service was not running and attempted to restart it Recommended Action Check if there is a resource conflict which prevents the said service from running For example the same TCP listener port may have been allocated to more than one service SCHEDULED_RELOAD FAILED Reload scheduled to occur at s failed s Severity Error Explanation An error occurred while trying to restart the system Scheduled reload may not function properly Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved SERVICE_FILESYSTEM_FULL Write to s for service s failed because the filesystem is full Severity Warning Explanation A service attempted to write a file and failed because the filesystem is full Recommended Action Please delete unused files to free up space EOS User Manual 147 CHAPTER 2 SYSTEM MESSAGES SSH_HOST_ KEY REGENERATED SSH host keys associated with a different system mac address s Regen
142. hes to enable tagged BPDU processing Recommended Action The switch received an 802 10 tagged Spanning Tree BPDU packet According to the IEEE Spanning Tree standards 802 1D 802 1w and 802 1s Spanning Tree BPDU packets are to be sent untagged Various vendors use proprietary extensions to the standard that send tagged Spanning Tree BPDU packets Arista Networks switches drop these tagged packets without further processing so the Spanning Tree protocol may not function properly on the receiving interface To fix this problem reconfigure the sending switch to transmit its Spanning Tree BPDU packets untagged This usually requires configuring the sending switch to use a single Spanning Tree or to use the IEEE standard Multiple Spanning Tree 802 1s mode of the protocol It may also require explicitly configuring the sending switch to send its Spanning Tree BPDU packets untagged Another workaround is to run the command 2 protocol encapsulation dotlq vlan x command TOPOLOGY ASSIGNED A spanning tree topology has been assigned to VLAN s Severity Info Explanation A VLAN that previously had no assigned topology due to maximum limit exceeded has now been assigned one Recommended Action No action is required this message is for information only TOPOLOGY LIMIT EXCEEDED No topology created for VLAN s The maximum number of supported topologies is s The number of configured VLANs is s more than the number of allowed topologies Sever
143. his is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved DDR_NO_LOCK Switch ASIC d DDR memory bank d was re initialized Severity Info Explanation When a switch ASIC does not recognize a DDR memory bank during initialization the switch ASIC is re initialized No impact to functionality Recommended Action No action is required this message is for information only DMA DEVICE STATE ERROR s expected state s actual state s Severity Error Explanation Device up down state changed unexpectedly Forwarding agent restarted in order to recover from this error Recommended Action No action is required this message is for information only DRAM INIT FAILURE DRAM d of s failed initialization It did not read back what was written to it Severity Error Explanation After initializing a Petra s DRAMs software verifies that it can write and read back from them If the value read back is not what was written to the DRAM software exits and retries the initialization This is normally a transient condition and the next initialization succeeds Recommended Action If the problem persists contact your support representative Otherwise no action is required EGRESS_CONSISTENT Egress buffer counters on s have returned to normal and the egress queues are operating normally Severity Error Explanation
144. his message is for information only SERVER DOWN Server s is down on interface s Severity Info Explanation Server is disconnected Either the connecting link is down or the server has shutdown Recommended Action No action is required this message is for information only SERVER INACTIVE Server s is inactive It was last seen on interface s Severity Info Explanation The server is either not responding to any request or there s no active traffic flow Hence it s assumed that the server is inactive Recommended Action No action is required this message is for information only SERVER MOVED Server s moved from interface s to s Severity Info Explanation The switch discovered a server previously learned on one interface on another different interface Recommended Action No action is required this message is for information only SERVER PROXY END Proxy service ended for server s on interface s Severity Notice Explanation Proxy service for the server has ended Either the proxy service lifetime elapsed or the interface connecting to the server is link up again Recommended Action No action is required this message is for information only SERVER_PROXY_IGNORED Proxy service for server s on interface s ignored due to static MAC entry Severity Notice Explanation Proxy service for the server is ignored as there is a static mac entry for the MAC Address of the server Recommended Action
145. iable again Recommended Action If the problem persists contact your support representative Otherwise no action is required POWER SUPPLY FAILED Power supply d has failed s Severity Error Explanation The power supply has failed and is no longer providing power to the system Recommended Action Replace the power supply POWER_SUPPLY_FAN_FAILURE_WARNING Power supply d fan failure predicted Severity Warning Explanation The power supply has detected that one of its fans is likely to fail The power supply will shut down once the fan fails Recommended Action Replace the power supply when possible Make sure that a redundant power supply is inserted and operating properly POWER SUPPLY INPUT OVERCURRENT_WARNING Power supply d input overcurrent detected latest reading dA Severity Warning Explanation The power supply detected a lower input voltage than expected If the problem persists the power supply will shut down Recommended Action Check the input power to the power supply POWER_SUPPLY INPUT_OVERPOWER_WARNING Power supply d input overpower detected latest reading dW Severity Warning Explanation The power supply has flagged an output overpower warning If the problem persists the power supply will shut down Recommended Action If the problem persists contact your support representative Otherwise no action is required POWER_SUPPLY_INPUT_OVERVOLTAGE_WARNING Power supply d input overvoltage de
146. idth was deallocated for a listener Recommended Action No action is required this message is for information only DOMAIN JOIN Domain Join s on s Class d Priority d SrVID d Severity Info Explanation MSRP Domain message was transmitted received on an interface Recommended Action No action is required this message is for information only DOMAIN LV Domain Lv s on s Class d Priority d SrVID d Severity Info Explanation MSRP Domain message was transmitted received on an interface Recommended Action No action is required this message is for information only ERROR s Severity Info Explanation MSRP error occurred Recommended Action No action is required this message is for information only LISTENER JOIN Listener Join s on s StreamlId 0x s state d Severity Info Explanation MSRP Listener message was transmitted received on an interface Recommended Action No action is required this message is for information only LISTENER LV Listener Lv s on s StreamId 0x s state d Severity Info Explanation MSRP Listener message was transmitted received on an interface Recommended Action No action is required this message is for information only NOTIF s Severity Info Explanation MSRP notification Recommended Action No action is required this message is for information only SR_CLASS_TRANSITION MSRP d state on s changed from d to d Severity Info Explanati
147. iled Severity Error Explanation Software detected a problem communicating to a repeater in the system Recommended Action If the problem persists contact your support representative Otherwise no action is required RETIMER_COMM_ERROR Smbus access to retimer s has failed Severity Error Explanation Software detected a problem communicating to a retimer in the system Recommended Action If this problem persists please contact your support representative for assistance SCHAN DMA ERROR Software detected an S Channel Accelerator DMA engine error on s Severity Error Explanation Each SandFap agent periodically executes diagnostic DMA read operations against each switching ASIC An error occurred on the latest DMA read attempt Recommended Action If the problem persists contact your support representative Otherwise no action is required SMBUS ERROR Card s mux poll failed d times before reappearing Severity Error Explanation Software detected a problem communicating to a smbus device Recommended Action If the problem persists contact your support representative Otherwise no action is required STANDBYCPLD COMMUNICATION ERROR Communication error with the standby domain CPLD s Severity Error Explanation An error occurred while giving commands over SMBus to a standby domain CPLD Recommended Action If the problem persists contact your support representative Otherwise no action is required SUPERVISOR IDENT
148. in Recommended Action No action is required this message is for information only HW MAX PATHS EXCEEDED Adjacency s has too many paths using only d Severity Error Explanation The switch is unable to program all paths of the route because the number of paths exceeds the maximum supported by the hardware The extra paths have been discarded from the route Recommended Action No action is required this message is for information only HW RESOURCE FULL Hardware resources are insufficient to program all routes Severity Error Explanation The switch is unable to program all routes due to insufficient hardware resources When the switch is unable to program routes due to insufficient hardware resources it may drop certain packets in order to avoid potential routing loops in the network The switch encountered this issue because the routing table exceeds the available hardware resources Recommended Action To solve this issue reconfigure the network to reduce the size of the routing table When the routing table size reduces the switch automatically programs any unprogrammed routes in hardware HW_RESOURCE_NORMAL All routes are programmed in hardware Severity Error Explanation The switch was able to program all the routes in the routing table in hardware and normal hardware routing has resumed Recommended Action No action is required this message is for information only IPTUNNEL_HW_RESOURCE_FULL Hardware resourc
149. insufficient to enable MLAG Mlag will be made inactive until the mirroring resources are available Severity Error Explanation The switch is unable to program mirroring session for logging certain packets traversing the peerlink to the CPU Recommended Action To solve this issue remove a mirroring session or unconfigure a feature that is using a mirror session MLAG_MIRROR_HW_RESOURCE_NORMAL Mirroring hardware resouces are now available to enable MLAG Attempting to make mlag active Severity Error Explanation Everything else being normal MLAG should be active shortly Recommended Action No action is required this message is for information only MROUTE_COUNTER_HW FULL Policer hardware resources are insufficient to program the mroute counter Severity Error Explanation The switch is unable to program the mroute counter due to insufficient policer hardware resources The mroute counter feature is either not able to reserve a new policer bank or has already used up the policer bank s it has reserved Recommended Action To solve this issue try to free up a policer bank used by some other feature MROUTE_COUNTER_HW_NORMAL All mroute counters are programmed in hardware Severity Error Explanation The switch was able to program all mroute counters in the hardware Recommended Action No action is required this message is for information only MROUTE INTERNAL ERROR Internal multicast routing error d s s d multic
150. ion EOS has started to uninstall the extension Recommended Action No action is required this message is for information only UNINSTALL_ERROR Extension s failed to uninstall s Severity Error Explanation The extension failed to uninstall The message may contain a reason why uninstallation failed such as a dependency from another installed extension Recommended Action Determine why the extension failed to uninstall Some extensions may not support uninstall requiring a reboot of the switch to remove the extension If you are unsure how to proceed contact the developer of the extension or your support representative EOS User Manual 33 CHAPTER 2 SYSTEM MESSAGES 2 19 FHRP Messages ADDR ERROR Failed to s a virtual address s s the kernel local routing table Severity Error Explanation VARP VRRP virtual address was not added removed from the kernel local routing table Recommended Action Check the configuration and ensure that VARP VRRP addresses are unique and do not conflict with interface addresses Also check that no manual entries were added to the linux local routing table ARPTABLES ERROR Failed to s an arptables rule for virtual IP s on interface s Severity Warning Explanation The arptables rule for a VARP virtual IP address was not added removed potentially leading to incorrect source IPs and source mac addresses inside the arp header in arp requests for ip addresses inside a virtual IP address sub
151. ion Software on the standby supervisor is being restarted The is necessary when a new startup config is received from the active supervisor while in Route Processor Redundancy Mode The standby supervisor may temporarily stop participating in the election protocol Recommended Action No action is required this message is for information only SWITCHOVER_COMPLETE Stateful switchover is complete Severity Notice Explanation This supervisor has completed stateful switchover Recommended Action No action is required this message is for information only SWITCHOVER START Stateful switchover started Severity Notice Explanation This supervisor has initiated stateful switchover Recommended Action No action is required this message is for information only SYNC_SLOW During SSO switchover s took longer than expected to sync its hardware shadow Severity Info Explanation During SSO switchover cards have an expected timeframe to sync their hardware shadow This card took longer than expected to sync its shadow Recommended Action No action is required this message is for information only TIME_SYNC Monotonic Time Synchronization failed Severity Notice Explanation Monotonic Time synchronization failed This could be either due to the standby supervisor not being able to communicate with the active supervisor or due to the standby supervisor s monotonic time being ahead in time by more than a second The sync op
152. ion on this system and its peer Ensure that all ports in the aggregate are connected to the same remote system and are all configured to be in the aggregate on the remote system FALLBACK_INACTIVE Reverting to normal LACP negotiation on interface s Severity Notice Explanation An LACP message was received on a member interface of a port channel after LACP fallback mode became active When this happens LACP fallback mode is deactivated and normal LACP negotiation is resumed Recommended Action No action is required this message is for information only FALLBACK_INDIVIDUAL Activating members of interface s as individual switchports without sucessful LACP negotation Severity Notice Explanation The LACP fallback timer expired on a port channel interface because no LACP messages were received on any of its member interfaces All members of this interface are being made active as individual switchports Recommended Action No action is required this message is for information only FALLBACK MISMATCH Unable to enter fallback mode on interface s due to mismatched fallback configuration with MLAG peer Severity Warning Explanation The port channel is unable to enter fallback mode because the peer and local switches are configured with different fallback modes Recommended Action Configure the port channel with the same fallback mode on each peer FALLBACK _ STATIC Activating one member of interface s without successful LACP
153. ired this message is for information only CLIENT DISCONNECTED Connection to s s closed Severity Info Explanation The connection between XMPP client and server closed Recommended Action No action is required this message is for information only DNS LOOKUP FAILURE DNS lookup for XMPP server s failed s Severity Error Explanation There was a problem resolving the XMPP server host name using the DNS Recommended Action Confirm the XMPP server hostname exists in the DNS that your switch has DNS name servers configured and that they are reachable GROUP_FORBIDDEN Forbidden from joining switch group s by server s s Severity Error Explanation The XMPP server has explicitly banned this switch from joining the switch group Recommended Action Check with the XMPP multi user chat room switch group owner as to why they have banned this switch GROUP_NOT_AUTHORIZED Incorrect password for switch group s Severity Error Explanation The XMPP server did not authorize the XMPP client to join the switch group Configure the correct password on the switch group for the group named in the error Recommended Action Check with the XMPP multi user chat room switch group owner what the password should be and configure that under management xmpp on the appropriate switch group line GROUP_REGISTRATION REQUIRED Members only switch group s requires pre registration Severity Error Explanation The switch group i
154. is message is for information only EXPECTED INGRESS_RESET Reset ingress blocks of switch chip s This is expected as part of config change Severity Info Explanation Software reinitialized the ingress blocks of the chip to apply some configuration This causes up to 50ms of traffic loss Recommended Action No action is required this message is for information only FABRICSERDES LINK FAILED SERDES s failed to link up with SERDES s d Severity Warning Explanation The specified SERDES in the sytem has failed to synchronize and link up with the peer SERDES This link will not be used for sending and receiving traffic anymore This may affect switching throughput on a fully loaded system Recommended Action If the problem persists contact your support representative Otherwise no action is required FABRIC_DMA_ERROR DMA operation of multicast table on s failed with s error Severity Error Explanation DMA operation of the given table failed on the specified Fabric card ASIC Recommended Action This might indicate a potential hardware issue in the specified Fabric Try powering off and powering back on the Fabric card using the configuration command no power enable module Fabricjnz If the problem persists contact your support representative FABRIC_FIFO_SIZE_ERROR s serdes s s FIFO size out of range size d max allowed size d Severity Error Explanation An unusual event has been detected Recommended
155. is required this message is for information only EOS User Manual 156 CHAPTER 2 SYSTEM MESSAGES 2 90 VMWAREVS Messages CONNECTION FAILED Failed to connect to VShield Manager Severity Error Explanation This error indicates that the VM Tracer agent could not connect to VShield Manager Recommended Action Check the configured URL in VM Tracer session configuration and verify network connec tivity to VShield Manager CONNECTION SUCCESSFUL Successfully connected to VShield Manager Severity Info Explanation The VM Tracer agent was able to successfully establish connection with the VShield Manager Recommended Action No action is required this message is for information only LOGIN ERROR Login to VShield Manager failed Severity Error Explanation This error indicates that the VM Tracer agent could not login to VShield Manager using the configured username and password Recommended Action Check the configured credentials in the VM Tracer session configuration REST_FAULT The REST request s failed Severity Error Explanation This error indicates that the VM Tracer agent could not complete the REST request to VShield Manager Recommended Action If the problem persists contact your support representative Otherwise no action is required SERVER VM Tracer detected an internal error in VShield Manager Severity Error Explanation This error indicates that the VM Tracer agent did not get a timely respo
156. its have been exceeded causing packets to be dropped Recommended Action If the problem persists consider redesigning your network to avoid congestion ERRDISABLE s error detected on s Severity Warning Explanation The switch detected the reported error condition on the interface and disabled the interface Recommended Action The switch detected the reported error condition errdisable cause on the interface As a precautionary measure and to avoid the error condition from affecting the switch network the switch disables the interface If recovery timer has been configured for the errdisable cause the switch will attempt to recover the interface after the recovery timeout The interface could also be recovered by performing the shutdown command followed by the no shutdown command in the interface configuration mode ETHTOOLFAIL SIOCETHTOOL s s interface s s Severity Error Explanation The Linux kernel reported an error when accessing the given interface Recommended Action If the problem persists please contact customer support HOST_FLAPPING Host s in VLAN s is flapping between interface s and interface s Severity Warning Explanation The MAC address was detected on multiple ports within a short timeframe Recommended Action It is recommended to check your network for loops or MAC address conflicts LINKMODEUNCONFIGURED Interface s link mode is unconfigured Severity Warning Explanation The interface s li
157. ity Warning Explanation Maximum allowed spanning tree topologies exceeded All traffic on this VLAN will be discarded Recommended Action Remove some active vlans to go within the maximum limit supported TOPOLOGY MISMATCH VLAN s is not on the same topology as its primary VLAN s Severity Warning Explanation A primary VLAN and its secondary VLANs must be on the same topology Spanning tree is disabled on any secondary VLAN that does not share a topology with its primary VLAN Recommended Action Assign the primary and secondary VLANs to the same topology EOS User Manual 136 CHAPTER 2 SYSTEM MESSAGES 2 78 SSO Messages DATA CHECKSUM ERROR SSO hardware shadow memory on standby does not match active for s Severity Info Explanation SSO software will take corrective action Recommended Action If the problem persists contact your support representative Otherwise no action is required PCIE DEVICE ERROR No PCIe NT bridge devices found for SSO hardware shadow Severity Error Explanation SSO software over PCIe will not work Recommended Action If this problem persists please contact your support representative for assistance PEER MANIFEST NOT_ACCEPTABLE Peer s SSO manifest differs Severity Error Explanation SSO manifest mismatch between active and standby Recommended Action If this problem persists please contact your support representative for assistance EOS User Manual 137 CHAPTER 2 SYSTEM MESSAGES
158. ity of the authentication server s EOS User Manual 3 CHAPTER 2 SYSTEM MESSAGES AUTHN_PLUGIN_NOT_READY Authentication method s is not ready Severity Warning Explanation Authenticating a user with this authentication method failed because the method is not ready This can occur if the method has not been fully configured Recommended Action Check to see if the authentication method has been configured AUTHZ FALLBACK Authorization method s is currently unavailable falling back to next method for action Gs Severity Warning Explanation The authorization method failed to provide an answer and is considered unavailable If the method list for this service contains a fallback method this request will be retried via that method Recommended Action Check the availability and reachability of the authorization server s AUTHZ_PLUGIN_NOT_READY Authorization method s is not ready Severity Warning Explanation Authorizing an action using this authentication method failed because the method is not ready This can occur if the method has not been fully configured Recommended Action Check to see if the authorization method has been configured CMD_AUTHZ_FAILED User s failed authorization to execute command s Severity Warning Explanation AAA denied authorization for the specified command Recommended Action Confirm that the user settings on authorization server s are correct EXEC_AUTHZ_
159. ix the method list configuration INVALID_AUTHENTYPE Invalid authentication type s requested Severity Error Explanation AAA received an authentication request containing an unknown authentication type Recommended Action Contact your support representative if error persists EOS User Manual 4 CHAPTER 2 SYSTEM MESSAGES INVALID_AUTHN METHODLIST Invalid authentication method list configured for service s method s is unknown Severity Error Explanation An attempt to authenticate a user for the service failed because the method list configured for the service contains a method name that does not match any available authentication plugins Recommended Action Fix the method list configuration INVALID_AUTHZ METHODLIST Invalid authorization method list configured for action s method s is unknown Severity Error Explanation An attempt to authorize an action failed because the method list configured for the action contains a method name that does not match any available authorization plugins Recommended Action Fix the method list configuration INVALID_RADIUS_SERVER RADIUS server s port d could not be used s Severity Warning Explanation The configuration contains a RADIUS server that could not be used One cause for this type of error is a hostname for which DNS resolution fails Recommended Action Correct the RADIUS server configuration INVALID_REGEX_IN_ROLE Rule d of
160. k Recommended Action While the power supply has recovered for now it should still be replaced as soon as possible POWER SUPPLY OUTPUT OVERCURRENT_WARNING Power supply d output overcurrent detected latest reading dA Severity Warning Explanation The power supply detected that it was providing a larger output current than expected This can happen 1f the system is drawing more power than the power supply can provide If the problem persists the power supply will shut down Recommended Action Check that the power supply can provide enough power to meet the system s requirements If the problem persists contact your support representative Otherwise no action is required POWER_SUPPLY_OUTPUT_OVERPOWER_WARNING Power supply d output overpower detected latest reading dW Severity Warning Explanation The power supply has flagged an output overpower warning If the problem persists the power supply will shut down Recommended Action If the problem persists contact your support representative Otherwise no action is required POWER SUPPLY OUTPUT OVERVOLTAGE WARNING Power supply d output overvoltage detected latest reading dV Severity Warning Explanation The power supply has flagged an output overvoltage warning If the problem persists the power supply will shut down Recommended Action If the problem persists contact your support representative Otherwise no action is required POWER_SUPPLY_OUTPUT_UNDERCURREN
161. k as expected Recommended Action No action is required this message is for information only OPERATIONAL_MODE_CHANGE Change of operational mode from tap aggregation to normal or vice versa will restart the s forwarding agent Severity Info Explanation The forwarding ASIC will be re initialized for the new mode on fowarding agent restart Recommended Action No action is required this message is for information only POLICY_HW_RESOURCE_FULL Hardware resources are insufficient to program all Tap Policies Severity Error Explanation The switch is unable to program all TapAgg Policy Maps due to insufficient hardware resources Recommended Action Reconfigure your TapAgg Policy Maps EOS User Manual 150 CHAPTER 2 SYSTEM MESSAGES 2 84 TCP Messages BADAUTH Invalid Unexpected No MDS digest from s d to s d Severity Notice Explanation Passwords of BGP peers are not identical Recommended Action Make sure that passwords if configured are configured on both peers and that they are identical EOS User Manual 151 CHAPTER 2 SYSTEM MESSAGES 2 85 TRANSCEIVER Messages AUTHENTICATION FAILED The transceiver for interface s has failed authentication manufacturer s model s rev s serial number s Severity Warning Explanation The specified transceiver has failed authentication It may be counterfeit Recommended Action Contact support arista com immediately AUTHENTICATION PROTOCOL FAILED The tra
162. l 9 CHAPTER 2 SYSTEM MESSAGES 2 5 ARP Messages RELOAD HITLESS NEIGHBOR STATE RESTORATION TIMEOUT Failed to restore state for d ARP and IPv6 Neighbor entries Severity Warning Explanation This may result in some traffic disruption during the hitless reload Recommended Action No action is required this message is for information only EOS User Manual 10 CHAPTER 2 SYSTEM MESSAGES 2 6 BED Messages INTERFACE _NOENT Invalid BFD peer Request by protocol s for peer d No such interface Severity Error Explanation A Bfd application has requested a Bfd peer add for an interface that does not exist Recommended Action No action is required this message is for information only STALE APP REG Bfd registration already present for peer s app s Severity Warning Explanation Trying to add a duplicate Bfd peer request for an application Recommended Action No action required STATE_CHANGE peer s changed state from s to s Severity Notice Explanation Peer s BFD state has changed Recommended Action No action required VRF_UNSUPPORTED Enabling BFD for s VRF s not supported Severity Error Explanation Enabling BFD on non default VRF not supported Recommended Action Undo BFD enabling config on non default VRF EOS User Manual 11 CHAPTER 2 SYSTEM MESSAGES 2 7 BGP Messages ADJCHANGE peer s old state s event s new state s Severity Notice Explanation The given peer has moved in
163. l continue to be cleared periodically EOS User Manual 12 CHAPTER 2 SYSTEM MESSAGES IF MAXROUTESWARNING Peer s has exceeded its configured maximum total number of routes d ROUTING INFORMATION IS BEING LOST Severity Notice Explanation BGP has received more routes than it is configured to handle from this BGP peer Routing information may be incomplete and may get further out of date New routes will no longer be added until enough routes are deleted to fall below this limit Recommended Action If this warning persists then determine whether the number of shared BGP routes is reasonable If not then try to reduce the number of routes being shared by your BGP peers If the number of routes is reasonable then increase the maximum routes limit MAXROUTES BGP has exceeded its configured maximum total number of routes d ROUTING INFORMA TION IS BEING LOST Severity Notice Explanation BGP has received more routes than it is configured to handle It will not accept any more routes Routing information may be incomplete and may get further out of date Recommended Action Determine whether the number of shared BGP routes is reasonable Then either reduce the number of routes being shared by your BGP peers or increase the maximum routes limit After taking either of these actions issue the clear ip bgp peer command to reset the BGP peer connection NOTIFICATION received from sent to neighbor s d d s s Yd
164. le to use the system until the problem has been solved STARTUP_CONFIG PARSE ERROR Errors encountered in parsing the startup config Severity Error Explanation One or more errors were encountered while parsing the startup config due to invalid incomplete and or unavailable commands Recommended Action Please run show startup config errors to look at the exact error s and fix them in the startup config STARTUP_CONFIG_TIMEOUT Timed out loading initial configuration Severity Emergency Explanation Loading the initial system configuration took longer than 60000 seconds Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved EOS User Manual 149 CHAPTER 2 SYSTEM MESSAGES 2 83 TAPAGG Messages HW RESOURCE FULL Hardware resources are insufficient to program all Tap Ports TapAgg Policy Maps Severity Error Explanation The switch is unable to program all Tap Ports TapAgg Policy Maps due to insufficient hardware resources Recommended Action Reconfigure your TapAgg Policy Maps or Tap ports OPERATIONAL_MODE Tap aggregation s Severity Info Explanation Tap aggregation feature is enabled or disabled Some features and or ports may be disabled if their configuration is not compatible with the current tap aggregation mode In exclusive mode the layer2 layer3 protocols may not wor
165. lity of the accounting server s ACCT_MSG_RESUME Resumed successful sending of accounting messages Severity Warning Explanation Accounting message successfully sent as the switch is able to contact the accounting server s Recommended Action No action is required this message is for information only ACCT_PLUGIN_NOT_READY Accounting method s is not ready Severity Warning Explanation Accounting an action using this accounting method failed because the method is not ready This can occur if the method has not been fully configured Recommended Action Check to see if the accounting method has been configured ACCT QUEUE FULL Accounting queue is full the oldest d messages will be dropped Severity Warning Explanation There were too many messages in the accounting queue and the switch discarded some pending messages to avoid consuming too many resources It normally means that the server was slow at taking the accounting messages Recommended Action Check the availability and reachability of the accounting server s AUTHN FALLBACK Authentication method s is currently unavailable falling back to next method for service Gs Severity Warning Explanation The authentication method failed to provide an answer and is considered unavailable If the method list for this service contains a fallback method this request will be retried via that method Recommended Action Check the availability and reachabil
166. m fans are operating correctly If the problem persists please contact your support representative for assistance POWERSUPPLY_OVERHEAT_WARNING s is overheating Severity Emergency Explanation The specified power supply has begun to overheat Recommended Action Check that system fans are operating correctly If the problem persists please contact your support representative for assistance POWERSUPPLY_TEMP NORMAL s temperature has returned to normal Severity Emergency Explanation The specified power supply was overheating but has now returned to a normal operating temperature Recommended Action No action is required this message is for information only PSU_FANS_ INCOMPATIBLE 2 or more incompatible power supply fans have been detected If not resolved the system will be shut down in d minutes Severity Emergency Explanation At most one PSU fan can be incompatible but more than one incompatible PSU fans have been detected The system will be shut down if the problem is not resolved Recommended Action Replace any incompatible PSU s immediately PSU_FANS_OK Previously incompatible power supply fans have been restored to be compatible with the system airflow The system will not shut down Severity Emergency Explanation Atleast all but one PSU fans must match the system airflow and they do now Recommended Action No action is required this message is for information only SUFFICIENTFANSRESTORED Sufficie
167. made inactive until the mirroring resources are available Severity Error Explanation The switch is unable to program mirroring session to sample packets to destination Recommended Action To solve this issue remove a mirroring session or unconfigure a feature that is using a mirror session RECOVERED Queue monitoring resumed Severity Debug Explanation Queue monitoring has recovered from a stall Recommended Action No action is required this message is for information only EOS User Manual 107 CHAPTER 2 SYSTEM MESSAGES STALLED Queue monitoring has paused briefly some congestion events may be lost Severity Debug Explanation Queue monitoring has stalled briefly Possible loss of congestion records may occur while it recovers Recommended Action No action is required this message is for information only UNEXPSEQNUM Congestion message with un expected sequence number is received s Severity Warning Explanation Reinitializing LANZ processor state Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 108 CHAPTER 2 SYSTEM MESSAGES 2 68 REACHABILITYMONITOR Messages EGRESS PROBE BURST DETECTED Reachability Monitor detected this switch has recently transmitted a burst of d probes in 1 second Severity Info Explanation These probes have been rate limited Recommended Action No action is required this message is f
168. me is the system name configured for the switch process The process is the system process that generated the message seq number The sequence number of the message The generation of sequence numbers is an optional configuration and is disabled by default The configuration com mand to generate sequence numbers is no service sequence numbers FACILITY The Facility that generated the syslog message These are the various modules used internally to manage all the functionality of the device Severity A number from 1 through 7 indicating the severity of the message 1 is most severe and 7 is the least severe See the section below to see a detailed de scription of severity levels Mnemonic This is a mnemonic code that uniquely identifies the message Mnemonic codes are all upper case character strings Message text This is the text of the system message containing details of the event Some messages have variable fields in the message which may contain MAC ad dresses interfaces names etc EOS User Manual 1 CHAPTER 1 SYSTEM MESSAGE OVERVIEW 1 2 Severity Levels The severity of a system message varies from O through 7 The lower the severity the higher the criticality of the message The different severity levels are described below Severity Description 0 Emergency system cannot be used Immediate administrator attention is re quired 1 Alert not used We use severity level Emergency f
169. mespace s for VRF s will be made Severity Warning Explanation The network namespace corresponding to the VRF could not be deleted Another attempt to delete the network namespace will be made Recommended Action If the problem persists contact your support representative Otherwise no action is required MAP OVERFLOW A VRF table used internally to map VRF names to VRF identifiers has overflowed at u values Severity Error Explanation When this happens the device may not be able to forward traffic in some VRFs This is likely caused by configuring more VRFs that than the device can support so a possible solution would be to unconfigure some VRFs Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved STUCK PROCESS Process s pid d is still using the namespace for VRF s s Severity Warning Explanation The process with the listed pid has not exited and is thus preventing the namespace for the VRF from being removed Recommended Action No action is required this message is for information only EOS User Manual 158 CHAPTER 2 SYSTEM MESSAGES 2 92 VRRP Messages ADDRESS INCOMPATIBLE VRRP MAC address s in s is incompatible with the most significant bytes of the currently programmed addresses s Addresses may only vary in the lower 3 bits Severity Error Explanati
170. n INTF_UNESTABLISHED Interface s is no longer in MLAG s Severity Info Explanation A local interface is no longer part of an MLAG Either it or its counterpart on the peer was either disabled or removed from the MLAG Recommended Action No action is required this message is for information only PEER_EVENT_CONNECTION_CLOSED The TCP session with the MLAG peer was closed Severity Warning Explanation The TCP connection between the MLAG peers was broken Recommended Action Wait until MLAG reconnects with the peer or enters the inactive state PEER_EVENT_HEARTBEAT_TIMEOUT MLAG stopped receiving heartbeats from the peer Severity Warning Explanation The TCP connection between the peers is intact but no heartbeat was received from the peer during the expected duration Recommended Action Wait until MLAG reconnects with the peer or enters the inactive state PEER_EVENT_RECONNECT The connection with MLAG peer s was reestablished MLAG state remains s Severity Warning Explanation MLAG successfully renegotiated with its peer Recommended Action None PEER EVENT STP_STABLE_TIMEOUT MLAG did not receive an STP stability response from the peer s Severity Warning Explanation An STP stability request was sent to the peer but no response was received during the expected duration Recommended Action Check the health of both Mlag agents Test and troubleshoot IP connectivity e g ping the configured MLAG peer address
171. n MAC address table was cleared by CLI command Recommended Action No action is required this message is for information only MAINTENANCE DOWN Interface s has been shutdown for maintenance Severity Info Explanation This interface has been shutdown for maintenance Recommended Action No action is required this message is for information only POLLLINKSTATUSFAIL Failed to poll link status on interface s s Severity Warning Explanation An attempt to poll the interface s status failed Recommended Action If the problem persists contact your support representative Otherwise no action is required REMOTEMACADDRBANKFULL Unable to program s remote host table entry for MAC address s in VLAN d due to hardware TCAM resource exhaustion Severity Warning Explanation The specified MAC address could not be programmed into the switching ASIC due to hardware TCAM resource exhaustion Packets destined to the address will be flooded Recommended Action Reduce the number of host table entries that need to be programmed into the switching ASIC One or more of the following steps might be helpful 1 Reduce the number of static mac entries 2 Clear dynamic mac table entries 3 Introduce additional layer 3 boundaries to reduce the number of MAC addresses Please contact your technical support representative if you need additional assistance REMOTEMACADDRBSTFULL Unable to program s remote host table entry for MAC address s i
172. n No action is required this message is for information only EOS User Manual 145 CHAPTER 2 SYSTEM MESSAGES CONFIG SESSION EXITED User s exited configuration session s on s s Severity Notice Explanation A network administrator has exited a configuration session without committing or aborting thereby having no effect on the running configuration fo the system Recommended Action No action is required this message is for information only CONFIG STARTUP Startup config saved from s by s on s s Severity Notice Explanation A network administrator has saved the system s startup configuration Recommended Action No action is required this message is for information only EVENT ACTION FAILED Event handler action s did not complete with exit code 0 s Severity Notice Explanation Event handler action did not exit normally Check the logs found at var log event eventName for more information and also examine the bash commands configured to run on activation if the failure persists Recommended Action No action is required this message is for information only EVENT ACTION FINISHED PAST EXPECTED Event handler action s finished running but ran longer than expected Severity Warning Explanation Event handler action has finished but took longer to run than the expected action timeout Recommended Action No action is required this message is for information only EVENT_ACTION_RUNNING_P
173. n Replace the broken missing or incompatible fans immediately CARDOVERHEATSHUTDOWN s temperature critical and is being shutdown Severity Emergency Explanation The specified card has surpassed its critical temperature and is being shutdown to prevent damage to the hardware Recommended Action Check that system fans are operating correctly If the problem persists please contact your support representative for assistance CARDOVERHEATWARNING s is overheating Severity Emergency Explanation The specified card has begun to overheat If the card continues to heat up it will be shutdown to prevent damage to the hardware Recommended Action Check that system fans are operating correctly If the problem persists please contact your support representative for assistance CARDSUFFICIENTFANSRESTORED Sufficient fans restored for s Severity Emergency Explanation Previously missing failed or incompatible fans have been replaced The card has enough fans to function properly and will not be shut down Recommended Action No action is required this message is for information only CARDTEMPNORMAL s temperature has returned to normal Severity Emergency Explanation The specified card was overheating but has now returned to a normal operating temperature Recommended Action No action is required this message is for information only FABRIC_MISSING d fabric card s missing Severity Emergency Explanation The speci
174. n The switch was unable to use the local port for an SSH Tunneling connection Recommended Action Use a different local port that is not being used by another program SSH_TUNNEL_LOG FILE TOO LARGE SSH Tunnel s had its log file grow too large The tunnel will be restarted since this is indicative of an issue Severity Warning Explanation The log file of an SSH Tunnel is generally a fixed size unless there is an issue Since the log file got too large a copy will be saved to the disk and the tunnel restarted Recommended Action Check syslog and the tunnels log file at etc ssh to determine if there are any issues SSH_TUNNEL_REMOTE_PORT_ERROR SSH Tunnel s is unable to open the port on the remote host Severity Error Explanation When the SSH Tunnel attempted to open a connection on the remote side it was prevented from doing so by the remote hosts SSH server Recommended Action Make sure the remote server allows TCP forwarding allows the configured port to be opened and the port is not the point of a resource allocation conflict SSH_TUNNEL_SLOW RESTART SSH Tunnel s will be delayed before restarting Severity Warning Explanation SSH Tunnels can only restart a limited number of times before they are delayed This is to prevent bad connections from attempting to connect over and over Once the tunnel successfully runs for some time fast restarts will work again Recommended Action Check for previous syslog messages regarding S
175. n VLAN d due to FFU BST hardware resource exhaustion Severity Warning Explanation The specified MAC address could not be programmed into the switching ASIC due to FFU BST hardware resource exhaustion Packets destined to the address will be flooded Recommended Action Reduce the number of host table entries that need to be programmed into the switching ASIC One or more of the following steps might be helpful 1 Reduce the number of static mac entries 2 Clear dynamic mac table entries 3 Introduce additional layer 3 boundaries to reduce the number of MAC addresses Please contact your technical support representative if you need additional assistance SETADDRFAIL Failed to set the MAC address of interface s to s Severity Warning Explanation An attempt to set the MAC address of the interface failed for an unknown reason Recommended Action If the problem persists contact your support representative Otherwise no action is required SETDISFAIL Failed to disable interface s Severity Warning Explanation An attempt to disable the interface failed for an unknown reason Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 29 CHAPTER 2 SYSTEM MESSAGES SETENFAIL Failed to enable interface s Severity Warning Explanation An attempt to enable the interface failed for an unknown reason Recommended Action If the problem persists contact
176. n brought back online Recommended Action No action is required this message is for information only SERDES_WITHDRAWN FROM FABRIC Serdes s withdrawn from the switch fabric Severity Warning Explanation A fabric serdes has been taken offline due to persistent serdes errors Recommended Action If the problem persists contact your support representative Otherwise no action is required SSO_NOT_SUPPORTED Redundancy protocol SSO for card s is not supported in this software version Severity Info Explanation In this software version Stateful Switchover support for this card is not available Recommended Action Configure redundancy protocol to RPR for thischassis STUCK SCHEDULER SHAPER Detected stuck scheduler shaper on s for flow d from s to s Severity Warning Explanation Software detected a possibly stuck scheduler shaper If confirmed software resets the egress scheduler of this switch chip to correct the condition Recommended Action If the problem persists contact your support representative Otherwise no action is required STUCK_VOQ INCONSISTENT QUEUE Software has detected that voq d of switch s pointing to fap d port d with traffic class d has dB of packets with no dequeues Found a queue table with inconsistent entries Severity Error Explanation No description needed Recommended Action No action is required this message is for information only STUCK_VOQ_WITH_CREDITS Software has detec
177. n interface was previously in the bridge assurance inconsistent state in order to avoid STP loops This state has been cleared and normal operation has resumed Recommended Action The port exited the inconsistent state either because it began receiving BPDUs again bridge assurance was disabled on the interface or the port is no longer configured a network port INTERFACE_DEL Interface s has been removed from instance s Severity Info Explanation The given interface is no longer running the given spanning tree instance Recommended Action No action is required this message is for information only EOS User Manual 133 CHAPTER 2 SYSTEM MESSAGES INTERFACE_SELF_LOOPED Interface s received its own bpdu blocking interface bridge mac s port id d Severity Warning Explanation The given interface received a bpdu that it transmitted To prevent a spanning tree loop from developing the switch blocks the interface Recommended Action The interface appears to be looped back to itself First find the source of the loop and remove it Then shutdown and re enable the interface to restore normal traffic flow INTERFACE STATE Interface s instance s moving from s to s Severity Info Explanation The spanning tree state of the interface in the given instance changed to the given new state Recommended Action No action is required this message is for information only LOOPGUARD BLOCK Loop guard blocking port s on s S
178. n is required this message is for information only NEIGHBOR TIMEOUT LLDP neighbor with chassisId s and portId s timed out on interface s Severity Notice Explanation An LLDP neighbor was deleted from the neighbor table since it timed out Recommended Action No action is required this message is for information only REMOTE_TABLES_CLEARED LLDP neighbor table cleared by s on s Severity Notice Explanation The LLDP neighbor table was cleared by a CLI command Recommended Action No action is required this message is for information only RX_RATELIMIT Exceeded Rx LLDPDU rate limit on s more than d LLDPDUs in f seconds Severity Warning Explanation The switch received too many LLDPDUs on a port in too short a period of time so we dropped the most recent received LLDPDU Recommended Action This could indicate a mis configured neighbor or a network loop Check the configuration of the neighbor connected to the interface and configure the LLDPDUs to be sent at a reasonable rate and ensure there are no network loops EOS User Manual 69 CHAPTER 2 SYSTEM MESSAGES 2 38 LOGMGR Messages CONSOLE LOGGING ERROR An error occurred initializing console logging Severity Warning Explanation Console logging may not function properly because an error occurred while setting access permissions Recommended Action If the problem persists contact your support representative Otherwise no action is required TCP_ SO
179. n not to be able to use the system until the problem is fixed PROGRAM NOTFOUND Error Program for s s not found but configured to run Severity Error Explanation A major feature might not work because the program that implements at least part of the feature can not be found Recommended Action This is a serious error Confirm that the package containing the program is correctly installed Plan not to be able to use the system until the problem is fixed SHORTSLEEP Waking up after sleeping only s of at least s requested Severity Debug Explanation ProcMgr was unable to delay the next review of the system for the minimum requested Recommended Action Keep an eye on the message If it appears frequently figure out why ProcMgr can t sleep as long as requested Is it being interrupted by signals SHUTDOWNREQUESTED ProcMer shutdown requested via SIGQUIT or SIGTERM to worker PID d Master ProcMgr PID d exiting Severity Error Explanation A requested shutdown of ProcMgr and all managed processes is being executed Recommended Action No action is required this message is for information only EOS User Manual 99 CHAPTER 2 SYSTEM MESSAGES SHUTDOWN SIGKILLALL ProcMgr shutting down terminating all managed procs s Severity Info Explanation ProcMgr is shutting down all processes under its management will be terminated with a SIGKILL The message lists the affected process IDs Recommend
180. nd plan to be unable to use the system until the problem has been solved SSD_WRITECACHE DISABLE FAILED Failed to disable write cache for SSD drive s Severity Error Explanation Failed to disable write cache on SSD drive Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved SYSTEM DEPRECATED This system is not supported The last supported EOS version for this system is s Severity Emergency Explanation The current hardware has been deprecated and is not supported by the running software System functionality is severely limited Recommended Action Install older software and reboot SYSTEM DRIVER Fatal software failure for this system Severity Emergency Explanation A fatal error occurred when attempting to instantiate management software for the system Recommended Action This is probably a problem with the installed software It may be necessary to upgrade software SYSTEM FAILURE Failed to read hardware description of this system code d Severity Emergency Explanation A fatal error occurred when attempting to read the factory programmed hardware description of this system This may be a hardware or software failure System functionality may be severely limited Recommended Action Install new software and restart the Fru Agent or replace the hardware EOS User Manual 41
181. ndition Contact the Arista TAC technical support group and send them this message This system may be unusuable until this issue is resolved VRMFATALERROR Fatal power error detected by VRM s Severity Emergency Explanation The VRM detected a fatal power error Functionality of the containing fru will be severely limited Recommended Action This is a critical condition Contact the Arista TAC technical support group and send them this message This system may be unusuable until this issue is resolved EOS User Manual 56 CHAPTER 2 SYSTEM MESSAGES WATCHDOG ERROR Reboot due to system watchdog Severity Warning Explanation The system rebooted due to a watchdog timeout Recommended Action Harmless if seen infrequently but may indicate a serious hardware or software problem if seen often EOS User Manual 57 CHAPTER 2 SYSTEM MESSAGES 2 26 IGMP Messages INTFID_CONFLICT Interface a is being used both implicitly and explicitly for Igmp groups Implicitly by an EOS Agent eg Vxlan and its also configured explicity Please choose different interface names for them Severity Warning Explanation Igmp interface names are in conflict with Igmp Agent and another Agent eg Vxlan Agent Recommended Action If the problem persists contact your support representative Otherwise no action is required VRF_UNSUPPORTED Interface a has a vrf a configured Severity Warning Explanation Enabling IGMP on a VRF enabled inter
182. negotiation Severity Notice Explanation The LACP fallback timer expired on a port channel interface because no LACP messages were received on any of its member interfaces Will attempt to make one member of the port channel statically active until LACP control traffic resumes Recommended Action No action is required this message is for information only PARTNER_CHURN LACP Partner Churn Detected on s Severity Warning Explanation LACP could not come to a decision on an aggregate Recommended Action Investigate the LACP configuration on this system and its peer Ensure that all ports in the aggregate are connected to the same remote system and are all configured to be in the aggregate on the remote system If not associated with simultaneous actor churn check if the remote system has aggregation limits that prevent this port from joining the aggregate RXDOT1QPKT An 802 1Q tagged LACP packet was received and discarded on interface s Severity Warning Explanation The switch received an 802 1Q tagged LACP packet Arista Networks switches drop these packets without further processing so the protocol may not function properly on the receiving interface To fix this problem reconfigure the sending switch to transmit its LACP packets untagged Recommended Action The switch received and discarded an 802 1Q tagged LACP packet LACP will not function properly on the receiving interface To fix this problem reconfigure the sending swi
183. net Recommended Action Delete and reconfigure the virtual IP addresses for which arptables rules failed to be added removed ARPTABLES_FLUSH_ ERROR Failed to flush arptables for network namespace s Severity Warning Explanation The arptables were not flushed properly when restarting Acl Arp requests sent from the router may use incorrect source IP and mac address when arping for ip addresses inside a VARP ip address subnet Recommended Action No action is required this message is for information only IPTABLES ERROR Failed to s an iptables rule for virtual IP s on interface s Severity Warning Explanation The iptables rule for a VARP VRRP virtual IP address was not added removed potentially leading to problems accessing the router via the virtual IP Recommended Action Try changing the accept mode for FHRP and then changing it back IPTABLES FLUSH ERROR Failed to flush iptables for network namespace s Severity Warning Explanation The iptables were not flushed properly when restarting Acl There may be problems accessing the router Recommended Action No action is required this message is for information only EOS User Manual 34 CHAPTER 2 SYSTEM MESSAGES 2 20 FLOW Messages TCAM ERROR Unable to add TCAM entry for OpenFlow DirectFlow flow s error s Severity Error Explanation The specified flow has not been created in hardware since TCAM entry could not be added Recommended Action If the err
184. nformation only INIT_TOO_LONG s has waited too long for s during initialization Exiting Severity Error Explanation The card has taken longer than expected to initialize Exiting and retrying Recommended Action If the problem persists contact your support representative Otherwise no action is required INTERRUPT_OCCURRED Interrupt s on s s Severity Error Explanation Parity Ecc errors have been detected in hardware Most of these errors will be corrected by software Recommended Action If the problem persists contact your support representative Otherwise no action is required IPV6_ROUTING_OVERFLOW s is unable to fit all the ipv6 routes in hardware due to lack of s All ipv6 routed traffic will be dropped Severity Error Explanation All ipv6 routed traffic will be dropped due to lack of hardware resources Recommended Action Reconfigure your network IPV6_ROUTING_OVERFLOW_RECOVERY_COMPLETED s recovered from ipv6 routing overflow Severity Error Explanation All ipv6 routes have been re added Recommended Action No action is required this message is for information only EOS User Manual 119 CHAPTER 2 SYSTEM MESSAGES IPV6_ROUTING_OVERFLOW_RECOVERY_STARTED s is starting to recover from ipv6 routing overflow Severity Error Explanation All ipv6 routes are being re added Recommended Action Reconfigure your network if ipv6 routing overflow persists ISEMA RESOURCE FULL Hardware resource
185. nk mode has not been configured The interface lacks a proper default configuration Recommended Action If the problem persists contact your support representative Otherwise no action is required LINKMODEUNSUPPORTED Unsupported link mode s for interface s Severity Warning Explanation The currently inserted transceiver does not support the link mode speed and or duplex that has been configured for the interface Recommended Action Configure the interface to use one of the supported link modes or replace the transceiver with one that supports the configured link mode EOS User Manual 28 CHAPTER 2 SYSTEM MESSAGES MACADDRBANKFULL Unable to program s host table entry for MAC address s in VLAN d due to hardware resource exhaustion Severity Warning Explanation The specified MAC address could not be programmed into the switching ASIC due to hash collisions in a bucket Packets destined to the address will be flooded Recommended Action Reduce the number of host table entries that need to be programmed into the switching ASIC One or more of the following steps might be helpful 1 Reduce the number of static mac entries 2 Clear dynamic mac table entries 3 Introduce additional layer 3 boundaries to reduce the number of MAC addresses Please contact your technical support representative if you need additional assistance MAC_ADDR_TABLE_CLEAR Clear MAC address table on s s by s on s s Severity Notice Explanatio
186. nsceiver for interface s is not responding as expected during authentication manufacturer s model s rev s serial number s Severity Warning Explanation The specified transceiver has failed authentication It may be counterfeit Recommended Action Contact support arista com immediately DISABLED The transceiver for interface s has been disabled because it is not qualified manufacturer s model s serial number s Severity Error Explanation The transceiver is not qualified It has been disabled Recommended Action Replace the transceiver with a qualified one EEPROMREADFAILED Timeout while trying to read ID EEPROM for transceiver s Severity Error Explanation The switch was unable to identify a newly discovered transceiver by reading its ID EEPROM Information about the transceiver is unavailable and the port can not be brought up Recommended Action Try re inserting the transceiver If the problem persists contact your technical support representative INCOMPATIBLE The transceiver for interface s has been disabled because it is not compatible transceiver type s manufacturer s model s serial number s Severity Error Explanation The transceiver is not compatible It has been disabled Recommended Action Replace the transceiver with a compatible one SPEED_UNSUPPORTED The transceiver for interface s is speed dG which the interface does not support Severity Error Explanation The transceiver is a s
187. nse to a request of VShield Manager Check the health of the VShield Manager server Recommended Action If the problem persists contact your support representative Otherwise no action is required XML_FAULT Unable to process XML from the REST request s Severity Error Explanation This error indicates that the VM Tracer agent could not process the xml returned from REST request of VShield Manager Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 157 CHAPTER 2 SYSTEM MESSAGES 2 91 VRF Messages CREATED VRF s has been created with network namespace s Severity Info Explanation The VRF instance has been successfully instantiated and The is now active Recommended Action No action is required this message is for information only CREATE RETRY Another attempt to create network namespace s for VRF s will be made Severity Warning Explanation The network namespace corresponding to the VRF could not be created Another attempt to create the network namespace will be made Recommended Action If the problem persists contact your support representative Otherwise no action is required DELETED VRF s has been deleted Severity Info Explanation The VRF instance has been successfully deleted Recommended Action No action is required this message is for information only DELETE_RETRY Another attempt to delete the network na
188. nt fans restored Severity Emergency Explanation Previously missing failed or incompatible fans have been replaced The system has enough fans to function properly and will not be shut down Recommended Action No action is required this message is for information only SYSTEMOVERHEATSHUTDOWN System temperature critical and will be shutdown s Severity Emergency Explanation The system has surpassed its critical temperature and will be shutdown to prevent damage to the hardware Recommended Action Check that system fans are operating correctly If the problem persists please contact your support representative for assistance EOS User Manual 25 CHAPTER 2 SYSTEM MESSAGES SYSTEMOVERHEATWARNING The system is overheating Severity Emergency Explanation The system has begun to overheat If the system continues to heat up it will be shutdown Recommended Action Check that system fans are operating correctly If the problem persists please contact your support representative for assistance SYSTEMSHUTDOWNDETECTED System was previously shutdown for environmental reasons Severity Warning Explanation The system was previously shutdown due to insufficient fans or critical system temperature Recommended Action Check the output of show reset cause for more information If the problem persists please contact your support representative for assistance SYSTEMTEMPNORMAL System temperature has returned to normal S
189. nt with identity s and MAC s timed out during authentication on port s Severity Warning Explanation A supplicant timed out during the authentication sequence on a 802 1X enabled port Recommended Action Examine the authentication software used if this persists UNKNOWN RADIUS SERVER RADIUS server group s references unknown server s Severity Warning Explanation The RADIUS server group contains a server that was not configured using the radius server host command Recommended Action Configure the unknown server or remove it from the server group EOS User Manual 22 CHAPTER 2 SYSTEM MESSAGES 2 15 ENVMON Messages CARDINSUFFICIENTFANSDETECTED Too few working fans detected for s If not resolved the card will be shut down in d minutes Severity Emergency Explanation Not enough fans of the correct type are functioning and this card will be shut down if the problem is not resolved Recommended Action Check that all fans are inserted and still spinning and replace and missing or broken fans immediately Check that all fans are of the same type i e front to back vs back to front airflow and replace any differing fans immediately CARDINSUFFICIENTFANSSHUTDOWN s is being shutdown due to insufficient fans Severity Emergency Explanation Too many fans have failed or are missing or fans of incompatible types have been inserted The card is being shut down to prevent damage Recommended Actio
190. of the following steps might be helpful 1 Reduce the number of static mac entries 2 Clear dynamic mac table entries 3 Introduce additional layer 3 boundaries to reduce the number of MAC addresses 4 Use fewer IP multicast groups NOMULTICASTGROUPS Insufficient hardware resources for multicast group s in VLAN d Severity Warning Explanation Insufficient hardware resources are available to program a forwarding entry for the multicast group which was learned via IGMP Snooping or static MAC table configuration There is a limit of d group address VLAN pairs and this limit has been exceeded As a result traffic sent to this multicast group will be forwarded to all ports Recommended Action Use fewer IP multicast groups STORMCONTROLLERTCAMCLEAR TCAM overflow condition for StormController setting on Unit d Port d has cleared Severity Warning Explanation The StormController setting has been programmed and traffic should be controlled Recommended Action Okay to rely on StormController for this port STORMCONTROLLERTCAMFULL Unable to find TCAM entry to set stormController on Unit d Port d Severity Warning Explanation The stormController setting can t be programmed into the switching ASIC due to exhaustion of TCAM entries Rate can t be controlled for this port for now Recommended Action Reduce the number of TCAM entries that are programmed into the switching ASIC One or more of the following steps might be helpful
191. ols to converge During hitless reload or stateful switchover this may lead to routes being deleted from hardware temporarily until the routing protocols converge Recommended Action No action is required this message is for information only EOS User Manual 113 CHAPTER 2 SYSTEM MESSAGES 2 71 ROUTING Messages ADJ SHARING MODE_CHANGE Operating adj sharing mode for agent changed to d Severity Info Explanation Adj sharing operating mode changed Restarting agent Recommended Action No action is required this message is for information only ECMP_ROUTE_MAX PATHS EXCEEDED ECMP route a has exceeded number of allowed paths Severity Info Explanation An ecmp route has more paths than allowed by the Resilient Ecmp Feature The extra paths will not be programmed in hardware Recommended Action No action is required this message is for information only ECMP_ROUTE PATH NOT PROGRAMMED Path a not programmed for ECMP route a Severity Info Explanation Path exceeds number of allowed paths in a resilient ecmp route Path will not be programmed in hardware Recommended Action No action is required this message is for information only EGRESS_RACL_SHARING_OVERRIDE_URPF Unicast RPF does not work and is disabled since egress router ACLs are configured Severity Warning Explanation Unicast RPF does not work when egress router ACL sharing is enabled Remove all egress router ACLs for unicast RPF to be enabled aga
192. ommended Action Check to see if the filesystem has run out of disk space Potentially from large log files Contact TAC Support if this problem persists UNKNOWN_RADIUS SERVER RADIUS server group s references unknown server s Severity Warning Explanation The RADIUS server group contains a server that was not configured using the radius server host command Recommended Action Configure the unknown server or remove it from the server group UNKNOWN_TACACS_MANDATORY_ATTRIBUTE Received unknown mandatory attribute s from Tacacs server Severity Error Explanation The authorization response from tacacs server includesone or more mandatory attributes we donot support failing authorization Recommended Action Change the TACACS server configuration UNKNOWN_TACACS_SERVER TACACS server group s references unknown server s Severity Warning Explanation The TACACS server group contains a server that was not configured using the tacacs server host command Recommended Action Configure the unknown server or remove it from the server group EOS User Manual 6 CHAPTER 2 SYSTEM MESSAGES 2 2 ACCOUNTING Messages CMD s task id d start_time d timezone s service s priv lvl d cmd s Severity Info Explanation Command accounting message Recommended Action No action is required this message is for information only EXEC s task _id d start_time d timezone s service s s
193. ommended Action Reconfigure the switch to free up tcam resources for ipv6 host route programming OR configure no ipv6 host route exact match to disable IPv6 host routes getting programmed in exact match table ROUTING _IP_TUNNEL_RESOURCE FULL Hardware resources are insufficient to program all IP tunnel entries Severity Error Explanation The switch is unable to program all IP tunnel entries due to insufficient hardware resources Recommended Action Reconfigure your network to reduce the number of IP tunnel entries in the switch ROUTING IP_TUNNEL RESOURCE NORMAL All IP tunnel entries are programmed in hardware Severity Error Explanation The switch was able to program all the IP tunnel entries in hardware Recommended Action No action is required this message is for information only ROUTING LEM RESOURCE FULL Hardware resources are insufficient to program all mac and host route entries Severity Error Explanation The switch is unable to program all mac and host route entries due to insufficient hardware resources Recommended Action Reconfigure your network to reduce the number of mac and host route entries in the switch ROUTING LEM RESOURCE NORMAL All mac and host route entries are programmed in hardware Severity Error Explanation The switch was able to program all the mac and host route entries in hardware Recommended Action No action is required this message is for information only ROUTING MPLS TUNNEL RESOURCE FULL
194. on MSRP SR Class state transition occurred on an interface Recommended Action No action is required this message is for information only TALKER ADV JOIN TalkerAdv Join s on s Streamld 0x s failureCode d Severity Info Explanation MSRP Talker Advertise message was transmitted received on an interface Recommended Action No action is required this message is for information only EOS User Manual 85 CHAPTER 2 SYSTEM MESSAGES TALKER_ADV LV TalkerAdv Lv s on s StreamId 0x s Severity Info Explanation MSRP Talker Advertise message was transmitted received on an interface Recommended Action No action is required this message is for information only TALKER _FAIL_JOIN TalkerFail Join s on s StreamId 0x s failureCode d failedBridgeld 0x s Severity Info Explanation MSRP Talker Fail message was transmitted received on an interface Recommended Action No action is required this message is for information only TALKER FAIL LV TalkerFail Lv s on s StreamId 0x s failureCode d Severity Info Explanation MSRP Talker Fail message was transmitted received on an interface Recommended Action No action is required this message is for information only EOS User Manual 86 CHAPTER 2 SYSTEM MESSAGES 2 52 MVRP Messages ERROR s Severity Info Explanation MVRP error occurred Recommended Action Please check if the interface is a trunk port and vlan is configured in the trunk allowed VLAN
195. on VRRP MAC addresses may only differ in the lower 3 bits Recommended Action Remove the incompatible VRRP groups ADDRESS RECOVERED Successfully programmed VRRP MAC address s in s that was previously unable to fit in hardware Severity Error Explanation Successfully programmed VRRP MAC address that previously was unable to fit in hardware Recommended Action No action is required this message is for information only AND_MLAG_PEER_MAC_CONFIGURATION CONFLICTING VRRP configuration will be ignored because Mlag peerMac is configured Severity Error Explanation VRRP and Mlag peerMac cannot be configured at the same time Recommended Action Remove either the VRRP or Mlag peerMac configuration AND MLAG PEER MAC CONFIGURATION NO LONGER CONFLICTING s configuration now in effect because s was deconfigured Severity Error Explanation VRRP and Mlag peerMac configuration no longer conflicting Recommended Action No action is required this message is for information only AND _VARP_ CONFIGURATION CONFLICTING VRRP configuration will be ignored because VARP is config ured Severity Error Explanation VRRP and VARP cannot be configured at the same time Recommended Action Remove either the VRRP or VARP configuration AND_VARP CONFIGURATION NO LONGER CONFLICTING s configuration now in effect because s was deconfigured Severity Error Explanation VRRP and VARP configuration no longer conflicting Recommend
196. on another port Recommended Action The supplicant will need to log off on former port in order to log on another port INVALID RADIUS SERVER RADIUS server s port d could not be used s Severity Warning Explanation The configuration contains a RADIUS server that could not be used One cause for this type of error is a hostname for which DNS resolution fails Recommended Action Correct the RADIUS server configuration NO_AUTHN_METHODLIST No authentication method list configured for 802 1x Severity Error Explanation An attempt to authenticate a port failed because there is no authentication method list configured for 802 1x Recommended Action Add an authentication method list for 802 1x NO VALID RADIUS SERVERS No valid RADIUS servers for method list s Severity Error Explanation The configuration contains an authentication method list that is not associated with any valid RADIUS servers Recommended Action Add at least one RADIUS server to the server group RADIUS FRAMED MTU_EXCEEDED Received from RADIUS server s a packet d bytes long which exceeds the port Framed MTU of d bytes Rejecting the Supplicant Severity Error Explanation The RADIUS server did not honor the Frame MTU attribute sent by the NAS Recommended Action Either increase the MTU of the port which is to be authenticated or configure the RADIUS server to honor the Frame MTU attribute in an Access Request packet SUPPLICANT_AU
197. on for the listed interface Correct it if this is not the desired configuration otherwise no further action is required LOOPGUARD_UNBLOCK Loop guard unblocking port s on s Severity Warning Explanation The listed interface received a BPDU and if the inconsistency was due to a unidirectional link failure the problem does not exist anymore The loop guard inconsistency is cleared for the interface which is taken out of the blocking state Recommended Action This is an informational message only no action is required MODE_CHANGE Spanning tree mode is now s Severity Info Explanation The spanning tree operating mode has changed Recommended Action No action is required this message is for information only MSTPVST_BORDER_CLEARED Cleared MST PVST border on s Severity Info Explanation The given interface is no longer a border port facing PVST region Recommended Action No action is required this message is for information only MSTPVST_BORDER_DETECTED Detected MST PVST border on s Severity Info Explanation The given interface is a border port facing a PVST region Recommended Action No action is required this message is for information only EOS User Manual 134 CHAPTER 2 SYSTEM MESSAGES MSTPVST_BORDER INCONSISTENT ENTER Interface s is entering the PVST inconsistent state Severity Warning Explanation The given interface is a border port facing PVST region However the interface is rec
198. only ACL_INNER_VLAN_MATCH_IGNORED Inner vlan match in ACL sj are supported only in TapAgg mode Severity Info Explanation Rules in ACLs having inner vlan match will be applied without inner vlan match condition Recommended Action No action is required this message is for information only ACL_MAPPER_CONFIG_CHANGE Change in ACL configuration in source port mapper requires a restart of the FocalPointV2 agent Severity Info Explanation ACLs in FFU will be re initialized at bootup with new mapper configuration Recommended Action No action is required this message is for information only ACL_PERMIT_LOGGING DISABLED ACL logging can t be enabled for permit rules in s due to hardware resource limitations Severity Error Explanation Release a mirror session and reapply your ACLs to enable permit logging Recommended Action No action is required this message is for information only AGILEPORT MODE CHANGE Change in agile port mode requires a restart of the FocalPointV2 agent Severity Info Explanation An agile port mode change occurs the first time an agile port is configured for 40G and when the last agile port configured for 40G is configured for 10G Recommended Action No action is required this message is for information only DMA ERROR s Packet DMA Error occurred in FocalPoint chip s Severity Error Explanation A fatal Error affecting cpu packet DMA occurred in a FocalPoint switching ASIC Focal
199. onnectivity from the switch to the TaskTracker and if TaskTracker name to IP address resolution can be performed from the switch TASKTRACKER_ REMOVED TaskTracker s is not longer part of the Hadoop cluster s Severity Info Explanation The TaskTracker is no longer part of the cluster as announced by the JobTracker Recommended Action No action is required this message is for information only EOS User Manual 74 CHAPTER 2 SYSTEM MESSAGES 2 43 MAX24305 Messages INIT FAILED Possible hardware error with the Max24305 chip Severity Error Explanation Initialization of the Max24305 chip has failed Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 75 CHAPTER 2 SYSTEM MESSAGES 2 44 MDIO Messages AGENT_OUTSTANDING_TXN_NOTICE The Mdio Agent has found unfinished transactions at startup even after waiting for d seconds Severity Notice Explanation The Mdio Accelerator HW is going to be reset which may cause Phy devices to be eventually reset due to unfinished transactions Recommended Action No action is required this message is for information only EOS User Manual 76 CHAPTER 2 SYSTEM MESSAGES 2 45 MIRRORING Messages ACL_HW_RESOURCE FULL Hardware resources are insufficient to program all mirror ACLs Severity Error Explanation The switch is unable to program all ACLs due to insufficient hardware resources Recomm
200. ooting the system Severity Notice Explanation Zero Touch Provisioning is rebooting the system after either a successful configuration of the system or because Zero Touch Provisioning was cancelled at the CLI Recommended Action No action is required this message is for information only RETRY Retrying Zero Touch Provisioning from the beginning attempt d Severity Notice Explanation Zero Touch Provisioning is retrying from the beginning To cancel Zero Touch Provisioning type zerotouch cancel at the CLI Recommended Action No action is required this message is for information only STARTUP FILE SYNC FAIL Failed to Synchronize the startup config file with the standby Severity Notice Explanation rebooting the Active and Standby Recommended Action No action is required this message is for information only EOS User Manual 166 CHAPTER 2 SYSTEM MESSAGES STARTUP_FILE_SYNC_TIMEOUT Waiting on File Replicator to synchronize the startup config Severity Notice Explanation with the Standby Recommended Action No action is required this message is for information only EOS User Manual 167
201. or critical messages 2 Critical not used We use severity level Emergency for critical messages 3 Error the system has encountered an error The message details help describe the urgency 4 Warning something may be wrong or misconfigured No immediate attention 1s required although further investigation is required 5 Notice not used We use severity level Information instead 6 Information informational message about the system Provides changes in operational status 7 Debug used for aiding in troubleshooting This could produce excessive out put and should not be used without discussing with your technical support rep resentative EOS User Manual 2 CHAPTER 2 SYSTEM MESSAGES Chapter 2 System Messages 2 1 AAA Messages ACCT_FALLBACK Accounting method s is currently unavailable falling back to next method for action s Severity Warning Explanation The accounting method failed to provide an answer and is considered unavailable If the method list for this service contains a fallback method this request will be retried via that method Recommended Action Check the availability and reachability of the accounting server s ACCT_MSG_DROP No available server accounting messages will be dropped Severity Warning Explanation None of the accounting servers are responsive and the switch will drop messages until the error is rectified Recommended Action Check the availability and reachabi
202. or information only EGRESS PROBE _BURST OK Reachability Monitor probes are no longer being transmitted in a burst Severity Info Explanation Probes are no longer rate limited Recommended Action No action is required this message is for information only EGRESS PROBE RATE EXCEEDED Reachability Monitor detected this switch is sending probes too quickly More than d probes per second are being sent by all streams on all transmitters Severity Warning Explanation The total rate for all egress streams is too high on this switch Recommended Action Please reduce the probe rate for some or all of the probe transmitters on this system or reduce the number of egress streams associated with these transmitters EGRESS _PROBE_RATE_OK Reachability Monitor probes are being transmitted at an acceptable rate Severity Warning Explanation Probe rate is within the limits allowed Recommended Action No action is required this message is for information only EGRESS_STREAM_TABLE_EXCEEDED Reachability Monitor detected this switch has exceeded the limit of od streams recorded in the egress stream table Severity Warning Explanation Too many streams have been received by the switch Recommended Action Please reduce the number of streams being sent from this switch EGRESS_STREAM_TABLE_OK Reachability Monitor detected this switch no longer exceeds the configured limit for the number of streams recorded in the egress stream table
203. or is because there is no space left in TCAM remove some flows and retry adding this flow EOS User Manual 35 CHAPTER 2 SYSTEM MESSAGES 2 21 FOCALPOINTV2 Messages ACL_COUNTER A Hardware resources to enable counting is available Severity Info Explanation Reapply to enable counting Recommended Action No action is required this message is for information only ACL_COUNTER FULL Hardware resources full Severity Info Explanation Counting will be disabled for some rules Acl s Recommended Action No action is required this message is for information only ACL_COUNTER NA Hardware resources to enable counting is not available Severity Info Explanation Counting Disabled for Aclj sz Recommended Action No action is required this message is for information only ACL DI NON ZERO INDEX MATCH IGNORED s match in ACL s is supported only when deep inspection payload 1 d skip value is 0 Severity Info Explanation Rules in ACLs having deep inspection aliases match will be applied without the aliases match condition Recommended Action No action is required this message is for information only ACL_DI_NO_TAPAGG_MATCH IGNORED s match in ACL sj is supported only in TapAgg mode Severity Info Explanation Rules in ACLs having deep inspection match will be applied without the deep inspection match condition Recommended Action No action is required this message is for information
204. or which DNS resolution fails Recommended Action Correct the RADIUS server configuration NO_VALID_TACACS SERVERS No valid TACACS servers for method list s Severity Error Explanation The configuration contains an authentication method list that is not associated with any valid TACACS servers One common cause for this error is a hostname for which DNS resolution fails Recommended Action Correct the TACACS server configuration EOS User Manual 5 CHAPTER 2 SYSTEM MESSAGES REMOTE LOGIN DENIED BY POLICY Remote login from s denied for user s due to authentication policy Severity Warning Explanation A remote login attempt was denied due to authentication policy For example the configured policy may prohibit remote logins for accounts with empty passwords Recommended Action No action is required this message is for information only ROOT PASSWORD NOTUPDATED Password setting for root not changed due to internal error s Severity Warning Explanation The password for the root user could not be changed from its current value The old password if any continues to be valid for the account This is a potential security risk Recommended Action If the problem persists contact your support representative Otherwise no action is required SSHKEY FILESYSTEM ERROR Error generating ssh key file at path s s Severity Error Explanation An ssh key creation attempt failed because of a filesystem error Rec
205. ot s is unsupported code d Severity Error Explanation The inserted card is not supported by the running software The card is not brought online Recommended Action Install software that supports the card CHASSIS_FAILURE Hardware failure when accessing the chassis Severity Emergency Explanation A fatal error occured when attempting to access the chassis Recommended Action Upgrade software or contact support System functionality may be severely limited CHASSIS_UNSUPPORTED Chassis is unsupported Severity Emergency Explanation The chassis is not supported by the running software System functionality may be severely limited Recommended Action Install software that supports the chassis DEVICE_DRIVER Fatal software failure for the device in slot s Severity Error Explanation A fatal error occurred when attempting to instantiate management software for the device Recommended Action Upgrade software to the current release Contact support if the problem persists following an upgrade DEVICE INSERTED Device in slot s has been inserted Severity Info Explanation Device insertion detected Recommended Action No action is required this message is for information only EOS User Manual 39 CHAPTER 2 SYSTEM MESSAGES DEVICE_REMOVED Device in slot s has been removed Severity Info Explanation Device removal detected Recommended Action No action is required this message is for information only
206. ped Severity Warning Explanation The switch has removed a neighbor s adjacent status There are many possible causes including invalid data received from a neighbor a change in which neighbors are eligible for adjacency or OSPFv3 being explicitly disabled on the switch or its neighbors Recommended Action Depending on the reason and other network conditions this may or may not require action STATE CHANGE Neighbor state change for aj on s isi to i Psi Severity Warning Explanation A neighbor s OSPF3 state has changed Recommended Action Usually no action is required This information can be useful for troubleshooting OSPF if the switch is not properly maintaining adjacency with one or more neighbors EOS User Manual 91 CHAPTER 2 SYSTEM MESSAGES 2 57 PFC Messages TIMEOUT EXPIRED The priority flow control pause timeout expired after d seconds for s queue s of interface s error disabling the port Severity Error Explanation The queue identified in the log message was continuously paused for longer than the watchdog timeout configured for the interface Recommended Action No action is required this message is for information only EOS User Manual 92 CHAPTER 2 SYSTEM MESSAGES 2 58 PIM Messages BFD STATE CHANGE neighbor s s to s on interface s Severity Notice Explanation The BFD state changed on the PIM neighbor Recommended Action No action is required this message is for
207. ped or transmitted cut through with a forced bad CRC but the error will have no further effect Recommended Action No action is required this message is for information only FW_LOAD_FAILED Failed to load firmware s Severity Emergency Explanation An error occurred while attempting to load firmware into the specified device s The device s are non operational until this problem is fixed Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved FW _LOAD_SLOW Programming firmware is unexpectedly slow s Severity Info Explanation Firmware was loaded into the specified device successfully but the process took longer than expected The device s is operating normally Recommended Action No action is required this message is for information only FW_UPDATE_DONE Finished updating firmware s Severity Info Explanation The firmware for the specified devices has been successfully updated Recommended Action No action is required this message is for information only FW_UPDATE_START Updating firmware s Severity Info Explanation The firmware for the specified devices is being updated This may take a few minutes and may delay system startup Recommended Action No action is required this message is for information only KERNEL PANIC EEPROM RW FAIL Failed to s ke
208. peed which the interface does not support Recommended Action Replace the transceiver with one which is 10G or 40G UNLOCK METHOD OBSOLETE Obsolete transceiver unlock method ignored Severity Warning Explanation An obsolete transceiver unlock method is configured on the switch Recommended Action Disable the obsolete transceiver unlock method EOS User Manual 152 CHAPTER 2 SYSTEM MESSAGES 2 86 TUNNEL Messages HW RESOURCE FULL Hardware resources are insufficient to program all tunnels Severity Error Explanation The switch is unable to program all tunnels due to insufficient hardware resources Packets to from one or more tunnels may not get forwarded in hardware Recommended Action Reconfigure your network to reduce the number of tunnels in the switch HW_RESOURCE_NORMAL Hardware resources to program tunnels are recovered Severity Error Explanation The switch was able to program all tunnels in hardware Recommended Action No action is required this message is for information only EOS User Manual 153 CHAPTER 2 SYSTEM MESSAGES 2 87 VM Messages SERVICE FAILED Failed to start the virtual machine service Severity Error Explanation Failed to start the virtual machine service Configured virtual machines may not be running properly Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 154 CHAPTER 2 SYSTEM MESSAGES
209. port representative with the contents of the message and plan to be unable to use the system until the problem has been solved EOS User Manual 14 CHAPTER 2 SYSTEM MESSAGES 2 9 CAPACITY Messages UTILIZATION HIGH s table utilization is currently at d crossed threshold d Severity Alert Explanation The hardware table utilization has crossed the configured alert threshold value and may be reaching its maximum limit Recommended Action Check the utilization of hardware table resources using show hardware capacity and remove unwanted entries configuration to free up space UTILIZATION_NORMAL s table utilization is back to normal Severity Alert Explanation The hardware table utilization has come below the configured alert threshold value Recommended Action No action is required this message is for information only EOS User Manual 15 CHAPTER 2 SYSTEM MESSAGES 2 10 CAPI Messages CERTIFICATE CONFIGURATION CONFLICT Certificate key pair in the SSL Profile will not be used Severity Warning Explanation A server certificate is configured in HTTPS config Only one server certificate can be configured at a time Recommended Action Remove the server certificate in HTTPS configwith no protocol https certificate in management apihttp commands RESET DIFFIE HELLMAN PARAMETERS FAILED Couldn t reset diffie hellman parameters Severity Warning Explanation Attempt to generate new Diffie Hellman
210. presentative Otherwise no action is required EOS User Manual 139 CHAPTER 2 SYSTEM MESSAGES MMU QUEUE RESERVED INVALID Request to reserve d bytes of memory for the MMU s cannot be satisfied Severity Info Explanation The number of bytes requested exceeds available memory Recommended Action Reduce the amount of memory that should be reserved by reconfiguring the trident mmu queue MODULE RESET Switch s restarting Cause s Severity Info Explanation A switch may restart due to configuration change or software defect Restarting one switch may cause other switches to restart Please see cause for more information Recommended Action No action is required this message is for information only MPLS ENTRY RESOURCE FULL Hardware resources are insufficient to add an MPLS route Severity Error Explanation The switch is unable to program the MPLS route for this action due to insufficient hardware resources Traffic forwarding will not happen via this MPLS route Recommended Action Reconfigure your network to reduce the number of MPLS routes in theswitch MPLS MAC DA PROFILE TABLE FULL Hardware resources are insufficient to add an MPLS adjacency for Ps Severity Error Explanation The switch is unable to create a destination MAC profile for the MPLS entry due to insufficient hardware resources Traffic forwarding will not happen to this MAC address Recommended Action Reconfigure your network to reduce the numbe
211. presentative Otherwise no action is required TXDMASTUCKERROR TX Packet DMA Stuck Error occurred in StrataA gent chip s Severity Error Explanation A fatal PCIE Error affecting cpu packet DMA occurred in a Strata switching ASIC Strata agent restarted in order to recover from this error Recommended Action No action is required this message is for information only EOS User Manual 141 CHAPTER 2 SYSTEM MESSAGES UNEXPECTED_L2MOD_FIFO_MAC_EVENT An unexpected 12mod fifo mac event is received msg s Severity Debug Explanation An unexpected 12mod fifo mac event is received Recommended Action No action is required this message is for information only UNEXPECTED RESTART Unexpected restart of Strata agent s occurred Severity Error Explanation Unexpected restart of the Strata agent occurred Recommended Action If the problem persists contact your support representative Otherwise no action is required URPF_CONFLICT_TABLE_MODE uRPF cannot be configured in hardware s table mode d is not supported with uRPF configuration Severity Info Explanation uRPF can only be configured when the table is in routing mode 2 or 4 and forwarding mode not 4 No other modes are supported with uRPF configuration Recommended Action No action is required this message is for information only URPF_ HW RESOURCE FULL Insufficient TCAM resources for programming uRPF ACL entries Severity Error Explanation The swi
212. problem persists contact your support representative Otherwise no action is required FPGA_PROGRAMMER ERROR Fpga programming failed for fpga s Severity Error Explanation Software detected a problem while configuring the given fpga Recommended Action If the problem persists contact your support representative Otherwise no action is required FPGA_STATIC_UPGRADED Successfully upgraded s system fpga Severity Info Explanation The above fpga was successfully upgraded Recommended Action No action is required this message is for information only FPGA_STATIC_UPGRADEFAILED Failed to perform an upgrade of the s system fpga Severity Emergency Explanation The system could not perform an upgrade of an fpga This may be due to a hardware or software failure System functionality will be severely limited Recommended Action If the problem persists contact your support representative Otherwise no action is required FPGA _STATIC_UPGRADING The upgrade of the s system fpga has begun Severity Info Explanation The above fpga is currently upgrading Recommended Action No action is required this message is for information only EOS User Manual 47 CHAPTER 2 SYSTEM MESSAGES FPGA_UNPROGRAMMED The FPGA s is unprogrammed Severity Emergency Explanation The given FPGA is unprogrammed and cannot be accessed possibly due to an interrupted or failed attempt at upgrading the FPGA Manual intervention may be
213. r of LSAs in the OSPF routing system has reached the configured limit too many times OSPF has been shut down until it is manually shut down and re enabled Recommended Action Identify the system that is advertising excessive LSAs or raise this system s max lsa configuration MAXLSAWARNING Current LSA count d is approaching configured limit d in OSPF instance d Severity Warning Explanation The number of LSAs in the OSPF routing system is approaching the configured limit If it reaches the limit the OSPF instance will shut down Identify the system that is advertising excessive LSAs Recommended Action Identify the system that is advertising excessive LSAs or raise this system s max lsa configuration STATE_CHANGE NGB a change from j sj to i s Severity Warning Explanation A neighbor s OSPF state has changed Recommended Action Usually no action is required This information can be useful for troubleshooting OSPF if the switch is not properly maintaining adjacency with one or more neighbors EOS User Manual 90 CHAPTER 2 SYSTEM MESSAGES 2 56 OSPF3 Messages ADJACENCY ESTABLISHED Neighbor a interface a adjacency established Severity Warning Explanation The switch has finished the OSPFv3 handshaking process with a neighboring switch and now sees it as adjacent Recommended Action No action is required this message is for information only ADJACENCY TEARDOWN Neighbor a interface a adjacency drop
214. r of MPLS entries in theswitch or use less interfaces for egress MPLS traffic MPLS _NEXTHOP_ RESOURCE FULL Hardware resources are insufficient to add an MPLS adjacency d Severity Error Explanation The switch is unable to program the nexthop for the MPLS entry due to insufficient hardware resources Traffic forwarding will not happen to this MPLS nexthop destination Recommended Action Reconfigure your network to reduce the number of MPLS nexthops in theswitch MPLS RESERVED ENTRY PROGRAMMING FAILURE Programming failure of MPLS table for required resources label d Severity Error Explanation The switch is unable to program a reserved entry in a hardware table that is necessary for MPLS to function properly Traffic forwarding of MPLS packets and other MPLS actions might not work Recommended Action Try power cycling the switch This problem should not occur under normal operation Likely the hardware is stuck in a bad state MPLS VC _AND SWAP TABLE FULL Hardware resources are insufficient to add an MPLS s label Severity Error Explanation The switch is unable to program the nexthop for the MPLS entry due to insufficient hardware resources The MPLS action will not take effect on this label Recommended Action Reconfigure your network to reduce the number of MPLS swap push labels in the switch PORTGROUP_MODE CHANGE Change in port group s configuration s has been enabled the StrataAgent will restart Severity Info
215. rare redundant state is provided against this occasion with repair logic built into the system SSD_DETECTION ERROR Failed to detect SSD on bootup Error msg s Severity Error Explanation Failed to detect SSD during system bootup This can happen if the device is not recognized by the driver or if the system encountered an error when booting up Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved SSD_PARTITION NOT_MOUNTED SSD partition s not mounted as mnt drive Severity Error Explanation The specified SSD partition is not currently mounted as mnt drive This can happen if the partition is not properly formatted or if the SSD device was not detected by the driver Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved SSD_UNEXPECTED PARTITION MOUNTED Unexpected partition s mounted as mnt drive Expected SSD partition s to be mounted as mnt drive instead Severity Error Explanation Expected the specified SSD partition to be mounted as mnt drive But a different partition got mounted as mnt drive This is unexpected Recommended Action This is a serious error Contact your customer support representative with the contents of the message a
216. rious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved PROCESS_RESTART Configuring process s to restart in role s Severity Info Explanation Launcher is configuring process s to be restarted by ProcMgr due to a changed process configura tion Recommended Action No action is required this message is for information only PROCESS START Configuring process s to start in role s Severity Info Explanation Launcher is configuring process s to be started by ProcMgr Recommended Action No action is required this message is for information only PROCESS_STOP Configuring process s to stop in role s Severity Info Explanation Launcher is configuring process s to be stopped by ProcMgr Recommended Action No action is required this message is for information only PROCMGR_WARMSTART Initiating warm start of ProcMgr worker Severity Info Explanation Launcher is initiating a ProcMgr worker warm start in order to get ProcMgr to start newly configured agents or to stop de configured agents This message should have been preceded by at least one message regarding process start restart or stop Recommended Action No action is required this message is for information only EOS User Manual 67 CHAPTER 2 SYSTEM MESSAGES 2 36 LINEPROTO Messa
217. rity Error Explanation The switch is unable to avoid ECN drops for non ECN Capable traffic due to insufficient TCAM resources Recommended Action Reconfigure other features that use TCAMs to free up some resources HW RESOURCE FULL TCAM resources are insufficient to program s for port s Severity Error Explanation The switch is unable to program QoS configuration due to insufficient TCAM resources Recommended Action Reconfigure other features that use TCAMs to free up some resources for QoS HW_RESOURCE_NORMAL s is programmed in TCAM for all ports Severity Error Explanation The switch was able to program entire QoS configuration in the TCAM Recommended Action No action is required this message is for information only POLICY_COUNTERS_ AVAILABLE A Policer bank is now available to enable counters for policy map based Qos Severity Error Explanation New policies applied will have counters enabled Reapply exisiting policies to enable counters on them Recommended Action No action is required this message is for information only POLICY COUNTERS UNAVAILABLE No Policer bank was available to enable counters for policy map based Qos Severity Error Explanation All policies will be programmed but counters will not be available Recommended Action Disable features that are using policer banks and re apply service policies POLICY HW RESOURCE FULL Insufficient hardware resources to program the s policy map s
218. rk as expected Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved VTEP_MIRROR_HW_RESOURCE FULL Mirroring hardware resources are insufficient to program default vtep learning entry Severity Error Explanation The switch is unable to program mirroring session for the default vtep learning entry When the switch is unable to program this default entry it will not be able to learn the remote vtep s or the remote mac addresses dynamically Only statically configured remote vtep s and remote mac addresses work Recommended Action To solve this issue remove a mirroring session on the switch and reconfigure the vxlan Please contact your technical support representative if you need additional assistance EOS User Manual 163 CHAPTER 2 SYSTEM MESSAGES 2 94 XMPP Messages CLIENT _AUTHEN FAIL Authentication failure connecting to s s Severity Error Explanation The authentication credentials provided are rejected by the configured XMPP server Recommended Action Confirm the authentication credentials configured for the XMPP server are correct by checking with your server administrator CLIENT_CONNECTED Connected to s s with JID s Severity Info Explanation The XMPP client is connected to the named server using the specified Jabber ID JID Recommended Action No action is requ
219. rnel panic eeprom Severity Info Explanation Software encountered failure in eeprom read write operation Recommended Action If the problem persists contact your support representative Otherwise no action is required MUX INIT ERROR Card s mux failed to initialize Severity Error Explanation Software was unable to configure the board s smbus mux Recommended Action If the problem persists contact your support representative Otherwise no action is required NOT_PRESENT Previously accessible hardware s is no longer accessible Severity Error Explanation Hardware which was previously accessible is no longer Possibly the linecard was removed or there is a PciE problem Recommended Action Remove and insert the card PCIE COMM ERROR Multiple smbus access to Pcie switch s have failed Severity Error Explanation Software detected a problem communicating to a pcie switch in the system Recommended Action If this problem persists please contact your support representative for assistance EOS User Manual 50 CHAPTER 2 SYSTEM MESSAGES PCIE_FATAL_ERROR Uncorrectable Fatal PCIe Error detected PCI device name s address s error count od Severity Error Explanation The PCIe fabric is no longer reliable Recommended Action If the problem persists contact your support representative Otherwise no action is required PCIE NONFATAL ERROR Uncorrectable Non Fatal PCIe Error detected PCI device name s ad
220. ro Touch Provisioning type zerotouch cancel at the CLI Recommended Action No action is required this message is for information only DHCP_SUCCESS DHCP response received on s Severity Notice Explanation Zero Touch Provisioning successfully received a DHCP response with a valid DHCP option 67 present from a server on the network Recommended Action No action is required this message is for information only EXEC_SCRIPT Executing the downloaded config script Severity Notice Explanation Zero Touch Provisioning is executing the downloaded config script Recommended Action No action is required this message is for information only EOS User Manual 165 CHAPTER 2 SYSTEM MESSAGES EXEC_SCRIPT_FAIL Config script exited with an error Error code s Severity Warning Explanation Zero Touch Provisioning failed to execute the downloaded config script This usually indicates a problem executing the config script or the config script exiting with a non zero return code Recommended Action Check the config script for any errors If the problem persists contact your support representative Otherwise no action is required EXEC SCRIPT SIGNALED Config script exited with an uncaught signal Signal code s Severity Warning Explanation Zero Touch Provisioning failed to execute the downloaded config script This usually indicates a problem executing the config script Recommended Action Check the config script for
221. rwise no action is required POWER OFF AFTER DDR PLL LOCKED FAILURE s is being powered off due to consecutive initialization failures Severity Error Explanation The initialization of switch ASICs DDR failed and the card is beingpowered off Recommended Action If the problem persists contact your support representative Otherwise no action is required POWER OFF AFTER PERSISTENT DMA FAILURE Powering off Linecard d because of d DMA health check failures within d hours Severity Warning Explanation The linecard was powered off due to persistent DMA failures on the linecard Recommended Action If the problem persists contact your support representative Otherwise no action is required QDR_ECC_ERROR Ecc errors occurred in s packet descriptor memory New d Total d Severity Error Explanation Ecc errors occurred in qdr packet descriptor memory of a switch chip If the problem continues to happen please contact support Recommended Action If the problem persists contact your support representative Otherwise no action is required RACL_MAX_LIMIT Additional RACL entries could not be programmed on s for s Severity Error Explanation RACLs on excess VLANs and VRRPs will fail Recommended Action No action is required this message is for information only REBOOT_ AFTER INIT_FAILURE Initialization of s switch ASICs failed Automatically rebooting switch to attempt recovery Severity Error Explanation The
222. s are insufficient to program all entries in ISEM A table Severity Error Explanation The switch is unable to program all tunnels or sub intfs or vlan mappings due to insufficient hardware resources Recommended Action Reconfigure your network to reduce the number of tunnels or sub intfs or vlan mappings in the switch ISEMA_RESOURCE NORMAL Hardware resources to program tunnels or sub interfaces or vlan mappings are recovered Severity Error Explanation The switch was able to program all tunnels sub intfs vlan mappings in hardware Recommended Action No action is required this message is for information only ISEMB_RESOURCE_FULL Hardware resources are insufficient to program all entries in ISEM B table Severity Error Explanation The switch is unable to program all tunnels or sub intfs or vlan mappings due to insufficient hardware resources Recommended Action Reconfigure your network to reduce the number of tunnels or sub intfs or vlan mappings in the switch ISEMB_RESOURCE_NORMAL Hardware resources to program tunnels or sub interfaces or vlan mappings are recovered Severity Error Explanation The switch was able to program all tunnels sub intfs vlan mappings in hardware Recommended Action No action is required this message is for information only MAX STORM CONTROL LEVELS CONFIGURED Cannot configure storm control s level for s in hardware maximum storm control levels per chip limit reached Severity W
223. s configured members only and this switch is not on the member list The owner must add the switch to the member list Recommended Action Contact the XMPP multi user chat room switch group owner and ask to have this switch added to the room member list EOS User Manual 164 CHAPTER 2 SYSTEM MESSAGES 2 95 ZTP Messages CANCEL Cancelling Zero Touch Provisioning Severity Notice Explanation Zero Touch Provisioning was cancelled at the CLI The system will reboot with Zero Touch disabled Recommended Action No action is required this message is for information only CONFIG DOWNLOAD Attempting to download the startup config from s Severity Notice Explanation Zero Touch Provisioning is attempting to download the startup config or a config script from the URL specified in the received DHCP response To cancel Zero Touch Provisioning type zerotouch cancel at the CLI Recommended Action No action is required this message is for information only CONFIG DOWNLOAD FAIL Failed to download the startup config from s Error s Severity Warning Explanation Zero Touch Provisioning failed to download the startup config or a config script from the URL specified in the received DHCP response Check the URL specified in the DHCP response To cancel Zero Touch Provisioning type zerotouch cancel at the CLI Recommended Action If the problem persists contact your support representative Otherwise no action is required CONFIG D
224. s required this message is for information only PERR FATAL s Severity Warning Explanation A fatal parity error occurred in a switching ASIC The forwarding agent restarted in order to recover from this error Recommended Action No action is required this message is for information only PHYTN_LOADING FIRMWARE Loading PHY firmware on interface s Link on this interface will briefly go down Severity Notice Explanation The firmware on the specified PHY is being reprogrammed Recommended Action No action is required this message is for information only PICASSO MEM ALLOC FAILED Picasso memory allocation failed Severity Warning Explanation Picasso failed to allocate memory for sso Picasso will disable sso feature Recommended Action No action is required this message is for information only EOS User Manual 51 CHAPTER 2 SYSTEM MESSAGES PLXEEPROM_UPGRADED Successfully upgraded PLX EEPROM to version in EOS image Severity Info Explanation Device was successfully upgraded Recommended Action No action is required this message is for information only PLXNIC_FATAL_ERROR A PCle fatal error occurred on the NIC port link between the supervisors Severity Error Explanation PCIe NIC port link between the supervisors reported a PCIe uncorrectable fatal error Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be
225. sses that run under ProcMgr control This message is informational only Recommended Action No action is required this message is for information only PROCESS CONFIG DUPLICATE Duplicate config for s detected Using the config with ctime d Severity Warning Explanation More than one config file contains configuration for the specified agent This can happen when the system is being reconfigured e g software is being installed upgraded uninstalled but should not persist for longer than a few minutes Recommended Action If the problem persists contact your support representative Otherwise no action is required PROCESS_DELAYRESTART s PID d restarted too often Delaying restart for s HH MM SS until s Severity Error Explanation The specified process has required restart too often In order to protect the system restart of the process is being delayed until the specified time Recommended Action Figure out why the process needs to be restarted so often and fix the problem EOS User Manual 98 CHAPTER 2 SYSTEM MESSAGES PROCESS_NOTRESTARTING Letting s PID d exit NOT restarting it Severity Info Explanation The specified process has stopped and ProcMegr will not restart it This could be due to the process being deconfigured for example Recommended Action No action is required this message is for information only PROCESS NOTSTARTING Error s can not be starte
226. tact your technical support representative if you need additional assistance HW_RESOURCE FULL Hardware resources are insufficient to program all NAT rules Severity Error Explanation The switch is unable to program all NAT rules due to insufficient hardware resources Recommended Action Reconfigure your NAT rules to reduce the size and or complexity of the NAT rules OVERLAPPED POOLRANGE NAT Pool range s s in pool s overlaps with range s s in pool dos Severity Error Explanation The behavior with overlapping pool range is undefined Recommended Action Reconfigure pool with a different pool range EOS User Manual 88 CHAPTER 2 SYSTEM MESSAGES 2 54 OPENFLOW Messages BIND MODE_CHANGE OpenFlow Bind Mode changed from s to s Severity Info Explanation OpenFlow Bind Mode has been changed Recommended Action No action is required this message is for information only CONTROLLER AUX CONNECT Controller s role s auxiliary channel connected Severity Info Explanation Controller Auxiliary connection is active Recommended Action No action is required this message is for information only CONTROLLER AUX DISCONNECT Controller s role s auxiliary channel disconnected Severity Info Explanation Controller Auxiliary connection is inactive Recommended Action No action is required this message is for information only CONTROLLER CONNECT Controller s role s connected Severity In
227. tch is unable to program ACL entries needed for uRPF due to insufficient TCAM resources As a result uRPF will not be enabled in hardware Recommended Action Reconfigure your ACLs to free up enough resources for uRPF VIRTUALPORT_RESOURCE_FULL Hardware resources are insufficient to add virtual port for s Severity Error Explanation The switch is unable to program virtual port remote VTEP or edge vlan port pair for the vxlan end point due to insufficient hardware resources Traffic forwarding will not happen on this virtual port Recommended Action Reconfigure the network to reduce the number of entries in the hardware table like remote VTEPs or edge vlan port pairs VLANXLATE RESOURCE FULL Hardware resources are insufficient to add s Severity Error Explanation The specified entry could not be programmed due to insufficient hardware resources Traffic forwarding will not happen on the specified entry Recommended Action Reconfigure the network to reduce the number of entries in the hardware table like vlan mappings edge vlan port pairs or vlan vni mappings VLAN ACL SHARING MODE CHANGE Change in resource sharing behavior for ACLs applied on VLAN interfaces Severity Info Explanation The forwarding agent will restart to share unshare ACL hardware resources attached across multiple VLAN interfaces Recommended Action No action is required this message is for information only VXLAN_MCAST_RESOURCE_FULL Hardware resources
228. tch to transmit its LACP packets untagged EOS User Manual 65 CHAPTER 2 SYSTEM MESSAGES 2 34 LAG Messages MEMBER_HW LIMIT EXCEEDED Interface s can not be added to s in hardware it already contains the maximum number of members d Severity Error Explanation Port channel group member limit exceeded Recommended Action Please remove this member from the port channel group MEMBER NO HW ID Interface s which is being removed from s does not have a valid hardware ID This may not be a problem if the interface was previously ignored due to membership overflow Severity Warning Explanation Port channel member missing hardware ID Recommended Action No action is required this message is for information only EOS User Manual 66 CHAPTER 2 SYSTEM MESSAGES 2 35 LAUNCHER Messages BOOT_STATUS reload hitless reconciliation complete Severity Info Explanation Prioritized agents participating in reload hitless have completed reconciliation Recommended Action No action is required this message is for information only PROCESS _MISCOMFIG Internal error process s in role s is misconfigured and can not be started This is a bug Reason s Severity Error Explanation The named process is misconfigured and can not be started The feature it implements can not be enabled The system is at least partially broken This is probably due to a bug Recommended Action This is a se
229. tected latest reading dV Severity Warning Explanation The power supply has flagged an input overvoltage warning If the problem persists the power supply will shut down Recommended Action If the problem persists contact your support representative Otherwise no action is required POWER_SUPPLY INPUT UNDERVOLTAGE WARNING Power supply d input undervoltage detected latest reading dV Severity Warning Explanation The power supply has flagged an input undervoltage warning If the problem persists the power supply will shut down Recommended Action Check the input power to the power supply POWER_SUPPLY_OK Power supply d has recovered Severity Error Explanation The power supply had previously failed but is now ok Recommended Action While the power supply has recovered for now it should still be replaced soon as possible POWER SUPPLY OUTPUT CURRENT FAILURE Power supply d has failed because output current dA dropped below the minimum allowed value dA Severity Error Explanation The power supply has failed and might no longer provide power to the system Recommended Action Replace the power supply EOS User Manual 53 CHAPTER 2 SYSTEM MESSAGES POWER_SUPPLY_OUTPUT_CURRENT_OK Power supply d has recovered from being declared as failed because of the output current dA being below the minimum allowed value dA Severity Error Explanation The power supply had previously failed but is now o
230. ted that voq d of switch s pointing to fap d port d with traffic class d has dB of packets with no dequeues in the last d ms It s credit balance is d and d credits have arrived in the same amount of time Severity Warning Explanation No description needed Recommended Action No action is required this message is for information only SWITCH_INIT_FAILED s s initialization failed Severity Error Explanation The initialization sequence of this switch asic failed This could be an intermittent problem and it will work next time If it persists it could be bad hardware Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 124 CHAPTER 2 SYSTEM MESSAGES TBL_LOCK_TIMEOUT SandHam table lock timed out Severity Error Explanation Software detected an excessive time required to acquire a lock required for accessing a Petra indirect table The agent was restarted Recommended Action If the problem persists contact your support representative Otherwise no action is required UNSUPPORTED URPF MODE Ignoring unsupported uRPF mode s Severity Error Explanation Configured uRPF mode is not supported on this platform Recommended Action Remove unsupported uRPF mode from configuration EOS User Manual 125 CHAPTER 2 SYSTEM MESSAGES 2 73 SANDACL Messages ROUTED PORT ACL SHARING MODE CHANGE ACLs applied on routed ports now sh
231. tes When the prefix routes reduces the switch automatically programs any unprogrammed multicast prefix routes in hardware Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved EOS User Manual 96 CHAPTER 2 SYSTEM MESSAGES 2 62 PROCMGR Messages CFGOPTION_ UNKNOWN Fatal error unknown ProcMegr config option in s s s Severity Emergency Explanation The specified config file contains an unknown config option The unknown option is listed Recommended Action Confirm that the packages containing ProcMgr is correctly installed Plan to not be able to use this system until the problem is fixed CONFIG_NOTFOUND Fatal error cfg file s not found Severity Emergency Explanation The system is unusable because the ProcMgr configuration file does not exist Recommended Action This is a serious error Confirm that the package containing ProcMgr is correctly installed Plan not to be able to use this system until the problem is fixed CONFIG_UNPARSEABLE Fatal error parse error while parsing cfg file s s Severity Emergency Explanation The system is unusable because the ProcMgr config file could not be parsed Was it corrupted or overwritten Recommended Action Confirm that the package containing ProcMgr is correctly installed Plan to not be able to use this syst
232. tialization failed Recommended Action No action is required this message is for information only INIT RECOVERED Initialization of SandTopo Agent succeeded Severity Info Explanation SandTopo agent has initialized successfully and is running normally Recommended Action No action is required this message is for information only EOS User Manual 127 CHAPTER 2 SYSTEM MESSAGES 2 75 SECURITY Messages ARP PACKET DROPPED Dropped ARP packet on interface s Vlan s because s Received s s Severity Warning Explanation ARP inspection dropped an ARP packet because it did not match an entry in the source binding database Recommended Action Determine why the bad ARP packet was sent and correct the issue ARP_RATE_EXCEEDED Exceeded ARP warning rate on s Severity Warning Explanation The switch received enough ARP packets to trigger this warning This can cause the port to become errdisabled depending on configuration ARP packets may also be delayed in processing by the CPU Recommended Action Determine why so many ARP packets are being sent and slow the rate to acceptable levels HW_ENTROPY_ERROR Hardware entropy generation is encountering errors s Severity Error Explanation Hardware entropy generation is experiencing problems and the device is being reset The SECU RITY_HW_ENTROPY_RECOVER message will be logged when the device is functioning properly Recommended Action If the problem persists contact
233. tion The above configuration was sucessfully synchronized from the active supervisor to the standby supervisor Recommended Action No action is required this message is for information only CONFIG SYNC FAILED Failed to synchronize s from Supervisor d active to Supervisor d standby Reason s Severity Warning Explanation The active supervisor failed to synchronize the above configuration to the standby supervisor Active supervisor will keep retrying to synchronize the configuration until successful The above configuration can be manually copied to the standby supervisor to ensure proper operation on switchover Recommended Action If the problem persists contact your support representative Otherwise no action is required CONFIG SYNC SUCCEEDED Synchronized s from Supervisor d active to Supervisor d standby Severity Warning Explanation After the previous synchronization failure the active supervisor persistenly retried and was able to synchronize the above configuration to standby supervisor Recommended Action No action is required this message is for information only ISSHD_RESTART FAILED isshd service failed to restart on Supervisor d standby Severity Notice Explanation The internal sshd service that runs on standby supervisor has stopped unexpectedly The service monitoring agent failed to restart it Recommended Action If the problem persists contact your support representative Otherwise no
234. tion only NO_ROUTE_OPTIMIZATION_OVERRIDE_URPF Unicast RPF is re enabled since optimized IP route program ming is not in effect Severity Warning Explanation Unicast RPF configuration is active again since optimized IP route programming is not in effect Recommended Action No action is required this message is for information only PERSISTENT_CONFIG_MOVED persist sys ribd ami is obsolete please use mnt flash rib startup Severity Error Explanation Persistent rib configuration in binary format in persist sys ribd ami is not recommended Put a plain text list of commands in mnt flash rib startup instead Recommended Action Archive the configuration using show tech support ribd running config flash old ribd config txt delete the old persist sys ribd ami and move any configuration that EOS does not support natively to mnt flash rib startup EOS User Manual 115 CHAPTER 2 SYSTEM MESSAGES ROUTE_OPTIMIZATION_OVERRIDE_URPF Unicast RPF does not work and is disabled since optimized IP route programming option is configured Severity Warning Explanation Unicast RPF does not work when optimized IP route programming is configured Unconfigure the option for unicast RPF to be enabled again Recommended Action No action is required this message is for information only EOS User Manual 116 CHAPTER 2 SYSTEM MESSAGES 2 72 SAND Messages AGENT EXITING Agent for s is exiting and will restart Severity
235. tive if the active supervisor fails Recommended Action No action is required this message is for information only EOS User Manual 111 CHAPTER 2 SYSTEM MESSAGES OTHER_ACTIVE Other supervisor became active Severity Notice Explanation The other supervisor has become active Now it will take over the management interface and control the linecards and fabric cards Recommended Action No action is required this message is for information only OTHER DISABLED Other supervisor became disabled Severity Critical Explanation The other supervisor has been disabled which means that it will not become active even if the active supervisor fails Now the switch is running with one supervisor less Recommended Action If you did not deliberately disable the other supervisor contact your support OTHER STANDBY Other supervisor became standby Severity Notice Explanation The other supervisor has become standby Now it is ready to become active if the active supervisor fails Recommended Action No action is required this message is for information only PROTOCOL_CHANGE Operational redundancy protocol changed to s Severity Notice Explanation The operational redundancy protocol changed to s due to conditions on the standby supervisor Recommended Action No action is required this message is for information only RESTARTING SOFTWARE Restarting software on Supervisor d standby Severity Notice Explanat
236. to or out of the Established state If it is not Established then route exchange with the BGP peer is not possible Recommended Action If the peering has gone down unexpectedly check the physical connection between the devices and the configuration of the system including IP and BGP on both ends CONVERGED BGP in VRF s has converged and its routes are in FIB Severity Notice Explanation BGP has converged after listening to updates from peers if any and is now ready to advertise best path routes to peers Recommended Action No action is required this message is for information only GRACEFUL_RESTART_TIMEOUT Deleting stale routing information from peer s Severity Notice Explanation Session with graceful restarting speaker has not been established within the advertised restart time Deleting the routes from this peer Recommended Action Check to see why the peer session did not get re established IF_MAXROUTESLIMIT Peer s has exceeded its configured maximum total number of routes d Put into idle state forever Severity Notice Explanation BGP has received more routes than it is configured to handle from this BGP peer BGP route information is no longer being exchanged with peer so no route additions or deletions will occur Routing information may be incomplete and may get further out of date Recommended Action Determine whether the number of shared BGP routes is reasonable If not then try to reduce the number o
237. us to a power controller Recommended Action If the problem persists contact your support representative Otherwise no action is required POWERCONTROLLER_OUTPUT_VOLTAGE RECOVERED The s power controller recovered from bad output voltage Severity Error Explanation Software detected that the power controller has recovered from not supplying the correct voltage on one or more of its rails Recommended Action If the problem persists contact your support representative Otherwise no action is required POWER OFF FAILED Software failed to power off the system Power cycle the system manually to recover Severity Error Explanation Software tried to power off the system but was unable because of a communication error with the system s CPLD Recommended Action If the problem persists contact your support representative Otherwise no action is required POWER SUPPLY DATA INVALID Power supply d returned unexpected status information multiple times Severity Warning Explanation Status information from the power supply is currently unreliable The power supply might no longer provide power to the system Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 52 CHAPTER 2 SYSTEM MESSAGES POWER_SUPPLY_DATA_OK Power supply d is returning expected status information Severity Warning Explanation Status information from the power supply is rel
238. utes model s rev s serial number s Severity Error Explanation Software detected a problem while attempting to power on a card Recommended Action If the problem persists contact your support representative Otherwise no action is required CARD_LOST_COMMUNICATION Communication with s has been lost PCIE FATAL ERROR signal is asserted model s rev s serial number s Severity Error Explanation Software detected a problem communicating to a PCle switch in the system Recommended Action If the problem persists contact your support representative Otherwise no action is required EOS User Manual 45 CHAPTER 2 SYSTEM MESSAGES CARD_LOST_POWER s unexpectedly lost power POWER_GOOD signal deasserted model s rev s serial number s Severity Error Explanation Software detected a problem with power on a card in the system Recommended Action If the problem persists contact your support representative Otherwise no action is required CARD POWERED OFF Card s has been powered off model s rev s serial number s Severity Info Explanation Software has powered down the card Recommended Action No action is required this message is for information only CARD POWERED ON Card s has been powered on model s rev s serial number s Severity Info Explanation Software has powered up the card Recommended Action No action is required this message is for information only CARD POWER CYCLE
239. utes are programmed in hardware Severity Error Explanation The switch was able to program all the multicast routes in hardware and normal hardware routing has resumed Recommended Action No action is required this message is for information only EOS User Manual 82 CHAPTER 2 SYSTEM MESSAGES 2 49 MRP Messages ERROR s Severity Info Explanation MRP error occurred Recommended Action No action is required this message is for information only JOIN MRP Join received on s attrType s key s state s event s Severity Info Explanation MRP Join was received on an interface Recommended Action No action is required this message is for information only LV MRP Lv s on s attrType s key Ps state s event s Severity Info Explanation MRP Lv was handled on an interface Recommended Action No action is required this message is for information only EOS User Manual 83 CHAPTER 2 SYSTEM MESSAGES 2 50 MSDP Messages GROUP LIMIT SA from peer a RP a for a a exceeded group limit of d for source prefix s Severity Warning Explanation Due to group limit configuration a received SA was rejected i e not stored in the SA cache Recommended Action No action is required this message is for information only MAX SA CACHE SIZE SA from peer a RP a for a a exceeded limit d on max size of SA cache Severity Warning Explanation Due to limits on the total size of
240. ver to the standby supervisor Severity Error Explanation Possible hardware removal Recommended Action No action required this message if for information only EOS User Manual 55 CHAPTER 2 SYSTEM MESSAGES SUPERVISOR _PCIE SWITCH_CONFIG_ERROR The Pcie switch s port s is misconfigured one or more cards will fail to operate Severity Emergency Explanation Software detected a configuration error in the Pcie switch this will prevent the system operating correctly Recommended Action Reboot the switch to try to recover the failure and contact your support representative for assistance SYSTEM_ABOOT IDENTIFICATION FAILED Failed to identify the aboot version on this system Severity Warning Explanation The aboot version could not be identified on this system If the aboot version is not compatible with the boot image the system may not behave reliably Recommended Action This is a serious error Contact your customer support representative with the contents of the message and plan to be unable to use the system until the problem has been solved SYSTEM_ABOOT_INCOMPATIBLE Aboot version s found on this system version number s is required Severity Emergency Explanation The Aboot version on this system is not compatible with the current boot image The system will be unusable Recommended Action Please upgrade the Aboot version or downgrade the boot image configured on this system SYSTEM IDENTIFICATION FAILED
241. verity Warning Explanation An ejector handle is closed on a fabric card The ejector handle is used to detect card removal and remove the fabric card from the system without dropping packets If the ejector handle is not properly closed software will be unable to detect that a card is about to be removed and will be unable to perform a graceful shutdown Recommended Action No action is required this message is for information only CARD EJECTOR OPEN AFTER INSERTION s s ejector handle was open after insertion This will prevent a clean shutdown of the card if it is removed and packets may be dropped Severity Warning Explanation An open fabric card ejector handle was detected The ejector handle is used to detect card removal and remove the fabric card from the system without dropping packets If the ejector handle is not properly closed software will be unable to detect that a card is about to be removed and will be unable to perform a graceful shutdown Recommended Action Make sure the ejector handle is properly closed CARD_EJECTOR_OPEN_SHUTDOWN Card s s ejector handle is now open and the card is being shut down Severity Warning Explanation An ejector handle on a fabric card is open The card will be shut down to prevent packet loss upon fabric card removal Recommended Action No action is required this message is for information only CARD_FAIL_TO_POWER_ON Card s failed to power on in state s will retry in d min
242. your support representative Otherwise no action is required HW ENTROPY FATAL ERROR Hardware entropy generation failed s s Severity Error Explanation Hardware entropy generation failed due to an unrecoverable error The Sol agent will restart Recommended Action If the problem persists contact your support representative Otherwise no action is required HW ENTROPY RECOVER Hardware entropy generation is now working properly Severity Error Explanation Hardware entropy was experiencing problems which have been corrected and the device is functioning properly again Recommended Action No action is required this message is for information only HW_ENTROPY START Hardware entropy generation started Severity Info Explanation Notification that the hardware entropy generation is running Recommended Action No action is required this message is for information only HW ENTROPY STOP Hardware entropy generation stopped Severity Info Explanation Notification that the hardware entropy generation is not running Recommended Action No action is required this message is for information only HW ENTROPY UNSUPPORTED s does not support hardware entropy generation Severity Warning Explanation Hardware entropy generation not supported on platform for the given reason Recommended Action No action is required this message is for information only IPSG_HW_RESOURCE_FULL Ingress TCAM resources are insuffici
243. ze SSL Diffie Hellman parameters has failed Recommended Action If the problem persists contact your support representative Otherwise no action is required SSL_DIFFIE_ HELLMAN PARAMETERS RESET FAILED Resetting SSL Diffie Hellman parameters failed Existing parameters will be used Severity Error Explanation Attempt to reset SSL Diffie Hellman parameters has failed Existing Diffie Hellman parameters will be used Recommended Action If the problem persists contact your support representative Otherwise no action is required SSL_PROFILE_INVALID SSL profile s is invalid Check show management security ssl profile s for details Severity Error Explanation The SSL profile is invalid Possible causes are missing certificate missing key mismatch of certificate with the key expired or not yet valid certificate and non root certificate in the trusted list Recommended Action Check show management security ssl profile command and fix the errors reported under Error column SSL_PROFILE_VALID SSL profile s is valid Severity Info Explanation The SSL profile is valid Recommended Action No action is required this message is for information only EOS User Manual 131 CHAPTER 2 SYSTEM MESSAGES 2 76 SERVERMONITOR Messages SERVER DISCOVERED Server s discovered on interface s Severity Info Explanation Server is discovered on the interface Recommended Action No action is required t

Download Pdf Manuals

image

Related Search

Related Contents

TRA2 - User Manual  10 - Airside Design.indd - Oregon State Library: State Employee  Philips SPR4500 PowerSquid 5 outlets Power multiplier  自己位置推定コンポーネント 取扱説明書 - OpenRTM-aist  Philips DLP5260  このPDFファイル  HÔTELS - Office de Tourisme de Mulhouse  LSI MegaRAID Remote Battery Kit Remote Battery Kit for LSIiBBU06  VXI Multi-Purpose Amplifier User's Manual  Pulsuhr „Speedmaster“  