Home

User Manual - VIAIR Corporation

image

Contents

1. Use caution when attached or removing air chuck from valve stems igus T Always ensure that tire valve stems are tight Bleeder Vaive before inflating tires Never inflate any tire or other inflatable past its rated pressure to avoid explosion or possible injury or death VIAIR TIRE INFLATION GUN Connect Stud USER MANUAL AUTOMATIC DEPLOYMENT AIR SYSTEMS TROUBLESHOOTING GUIDE PROBLEM Tank pressure drops when compressor s shut off Compressor runs continuously and air flow lower than normal Compressor runs continuously causing safety valve if equipped to open Excessive moisture in discharge Compressor will not run Thermal overload protector cuts out repeatedly Excessive knocking or rattling POSSIBLE CAUSE S Loose drain cock Check valve leaking 3 Loose connections Excessive air usage Loose connections Worn piston ring or inlet valve Clogged air filter element Bad pressure switch Defective safety valve Excessive water in air tank High humidity No power or power switch in OFF position Blown fuse Motor overheats Pressure switch failure Lack of proper ventilation or ambient temperature is too high Compressor valves failed Loose mounting bolts Worn bearing on eccentric or motor shaft 3 Cylinder or piston ring is worn CORRECTIVE ACTION Tighten drain cock Replace check valve or compressor s Check all connections
2. Your Vital Air Source 40041 Heavy Duty ADA System with Booster Bracket for 2007 2011 JK 40044 Heavy Duty ADA System with Booster Bracket for 2012 to Current JK 40049 Heavy Duty ADA System Universal for all vehicles booster bracket not included 45041 Constant Duty ADA System with Booster Bracket for 2007 2011 JK _ 45055 Constant Duty ADA System Universal for all vehicles booster bracket not included l K i N 73 7 yy Ya Sy gt ay a Ni IMPORTANT It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL C AUTOMATIC DEPLOYMENT AIR SYSTEMS IMPORTANT SAFETY INSTRUCTIONS PLEASE NOTE Extreme care should be taken to mount the compressor on the ADA brake booster mounting bracket in such a way that the compressor mounting bolts do not interfere with any brake lines running below the bracket If the mounting bracket is not installed precisely and with care the brake lines on your Jeep JK may come into close proximity with the compressor s mounting hardware and mounting bracket Damage to brake lines from continued contact can cause brake system failure If you have any questions please contact VIAIR Corporation at 949 585 0011 CAUTION To reduce risk of electrical shock or electrocution Do not disasse
3. 10 Min On 30 Min Off 10 Min 40 Min 25 Duty Cycle DUTY CYCLE REFERENCE CHART DUTY CYCLE 100PSI 72 F MINUTES ON OFF 15 6 Min On 34 Min Off 20 8 Min On 32 Min Off 25 10 Min On 30 Min Off 30 13 Min On 30 Min Off 33 15 Min On 30 Min Off 100 Continuous Duty ABOUT RATED WORKING PRESSURE To ensure trouble free service life of your compressor always operate compressor within rated working pressure of the compressor Never use a pressure switch with a higher cut off pressure than compressor s rated working pressure WIRE GAUGE GUIDE 12 VOLT WIRE GAUGE GUIDE 24 VOLT 10 30 Ta a a ae 15 12 10 10 8 5 te 14 142 12 10 20 90 0 8 6 6 20 14 142 10 10 140 2 tioj es _6 6 1 6 _ a ete 10 an tig Amp Draw Amp Draw ed reo es Pe Pa te te reo 10 fe 6 e a LIMITED WARRANTY VIAIR Corporation warrants this product when properly installed and under normal conditions of use to be free from defects in workmanship and materials for a period of one year from its original date of purchase To receive warranty service or repair please contact VIAIR Corporation Returns should be made within one year of the date of purchase after a Return Goods Authorization RGA number has been assigned by VIAIR Corporation To obtain RGA fax a copy of your receipt to 949 585 0188 For complete warranty details please visit www viaircorp com warranty PLEASE NOTE
4. the air compressor 3 Your air compressor is equipped with an AUTOMATIC THERMAL OVERLOAD PROTECTOR This feature is designed to protect the air compressor from overheating and causing permanent damage to your air compressor The thermal overload protector will automatically cut power to your air compressor should the internal operating temperature of the air compressor rise above safe levels during excessive use 4 Should at any time during use your air compressor automatically shuts off unexpectedly do not attempt to restart it Turn off power and allow unit to cool for at least 30 minutes This will allow the Thermal Overload Protector to reset so you can safely resume use of the air compressor 5 To prevent discharge of your vehicle s battery and enhance performance keep the vehicle s engine running while using the compressor 6 Only operate compressor in well ventilated areas NOTE Your ADA System is equipped with an 85 PSI turn on 105 PSI turn off pressure switch Due to manufacturing tolerances a variance of 5 is possible for turn on amp off pressures This is not a manufacturing defect and will not affect the operation of air lockers nor the ability of the ADA System to inflate tires up to 100 PSI MAINTENANCE amp REPAIRS 1 Periodically check all electrical and fittings connections Clean and tighten as needed 2 Periodically check all mounting screws Tighten as needed 3 Replace air filter element periodica
5. THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE Your Vital Air Source 15 EDELMAN e IRVINE CA 92618 TEL 949 585 0011 FAX 949 585 0188 www viaircorp com
6. as inside your vehicle or in the bed of your pickup use the appropriate gauge wire for the amp draw of the compressor and distance from the battery When in doubt use the next larger wire gauge size USER MANUAL AUTOMATIC DEPLOYMENT AIR SYSTEMS MOUNTING AND WIRING 1 10 11 12 13 14 15 Disconnect ground cable from vehicle s battery Position the air compressor in the location where it will be mounted If brake booster mounting is provided desired based on type of ADA System install brake booster bracket either with the compressor in place or afterwards if this eases installation Note If your ADA System is equipped with a brake booster bracket you must remove the corresponding hardware from the brake booster to properly install the booster bracket Reinstall all removed hardware following the manufacturer s torque specifications for installation of any hardware removed For 2007 2011 JK Models the compressor intake filter should face the vehicle s firewall Quick connect coupling should face radiator support For Universal Models mount air compressor to either a flat surface or to the brake booster mounting bracket with the bolts nuts washers and locking washers provided NOTE For remote inlet air filter installation refer to instructions included in the Remote Inlet Air Filter Pack Route the provided wiring harness from the mounting location of the ADA System to the battery of your vehicle Sec
7. e 158 F Min Ambient Temperature 40 F Auto Reset Thermal Protection Yes USER MANUAL AUTOMATIC DEPLOYMENT AIR SYSTEMS CONSTANT DUTY ADA PART NUMBERS e 45041 Constant Duty ADA System with Booster Bracket for 2007 2011 JK e 45055 Constant Duty ADA System Universal Motor Voltage Max Current Consumption Motor Type Horsepower Max Working Pressure Max Duty Cycle 72 F amp 100 PSI Minutes On Off 72 F amp 100 PSI Max Restart Pressure Max Ambient Temperature Min Ambient Temperature Auto Reset Thermal Protection booster bracket not included 12 volts 19 amps Permanent Magnetic 1 4 150 PSI 100 Continuous 200 PSI 158 F 40 F Yes ADA SYSTEM WIRING SCHEMATIC i Battery Delphi Connector Delphi Connector Harness Harness oN ot I Harness USER MANUAL AUTOMATIC DEPLOYMENT AIR SYSTEMS DIGITAL TIRE INFLATION KIT The VIAIR Digital Tire Inflation Kit is used for airing up tires and adding compressed air to any inflatable item with a valve stem The Digital Tire Inflation Kit has a normally closed lever style air chuck at the end of its rubber hose and comes with a 30 hose After connection to an air source such as an air tank via the quick connect stud preinstalled in the unit air may be discharged from the gun by simply squeezing the inflation trigger To check air pressure turn on the digital air pressure gauge and select
8. es when operating this product Use only in well ventilated areas INSTALLATION Please read and follow the installation instructions carefully to avoid injury or damage to the compressor or your vehicle Each of our air compressors and parts have been carefully produced and packaged Before you begin installation please familiarize yourself with ADA System Components List of this manual Guidelines for Selecting Mounting Location The selection of proper mounting location for your air compressor will help ensure a long and trouble free compressor service life Please pay close attention to the following guidelines FOR UNIVERSAL MODELS 1 Select a FLAT UPRIGHT AND SECURE location where the compressor can be mounted FOR ALL MODELS 2 The cooler the ambient temperature the less chance the compressor will overheat For prolonged use tire filling open your hood to allow maximum cooling of the compressor unit 3 This compressor is moisture amp dust resistant but NOT DIRT OR WATERPROOF Do not mount compressor in locations where the unit is likely to come in contact with the elements 4 Always utilize the supplied remote filter mounting option and route the air line from Compressor air inlet to remote inlet air filter located in a clean and dry area Secure the air filter to keep it from dislodging and becoming damaged FOR UNIVERSAL MODELS 5 If it is necessary to mount the air compressor further away from the battery such
9. lly Replacement frequency depends on operating frequency and operating environment For frequent use in dusty environment we recommend that you replace air filter element at least once a month 4 Regularly clean dust and dirt from compressor cooling fins and or motor housing 5 Your air compressor is equipped with a permanently lubricated maintenance free motor Never try to lubricate the compressor 6 All repairs should be performed by Manufacturer or Manufacturer s Authorized Service Agencies only 7 For complete information regarding VIAIR Warranty please visit www viaircorp com warranty CAUTION Never touch the air compressor or fittings connected to the air compressor with bare hands during or immediately after use The leader hose and fittings connected to leader hose will become very HOT during and after use If necessary wear heat resistant gloves to handle fittings air line and leader hose SPECIFICATIONS HEAVY DUTY ADA PART NUMBERS e 40041 Heavy Duty ADA System with Booster Bracket for 2007 2011 JK e 40044 Heavy Duty ADA System with Booster Bracket for 2012 to current JK e 40049 Heavy Duty ADA System Universal booster bracket not included Motor Voltage 12 volts Max Current Consumption 26 amps Motor Type Permanent Magnetic Horsepower 1 4 Max Working Pressure 150 PSI Max Duty Cycle 72 F amp 100 PSI 33 Minutes On Off 72 F amp 100 PSI 15 On 30 Off Max Ambient Temperatur
10. mble Do not attempt repairs or modifications Refer to qualified service agencies for all required service and repairs Do not use this product in or area where it can fall or be pulled into water or other liquids Do not reach for this product if it has fallen into liquid Use this compressor with 12 volt DC systems only This product should never be left unattended during use WARNING To prevent injury Never allow children to operate this compressor Close supervision is necessary when this compressor is being used near children This compressor will become very HOT during and immediately after use Do not touch any part of this compressor with bare hands other than the ON OFF switch during and immediately after use Do not use this product near flames or explosive materials or where aerosol products are being used Do not operate this product where oxygen is being administered Do not pump anything other than atmospheric air Never use this product while sleepy or drowsy Do not use any tools or attachments without first determining maximum air pressure for that tool or attachment Never point any air nozzle or air sprayer toward another person or any part of the body This air compressor is equipped with an Automatic Reset Thermal Protector and can automatically restart after the thermal protector resets Always cut off power source when thermal protector becomes activated Wear safety glasses or goggl
11. s that are leaking The use of thread locker is recommended for all fittings Avoid the use of Teflon tape ADA SYSTEM COMPONENTS LIST Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty 1 ADA System compressor with pre installed safety valve drain 85 105 PSI pressure switch 8 1 4 NPT hex port plugs quick connect coupler and Delphi connector 1 Digital tire inflation gun 1 30 polyurethane hose with automatic couplers 2 BSP adapters 1 4 NPT to 1 8 BSP 1 40 amp blade style fuse 1 1 NPT male barbed fitting for 1 4 air line for remote mount air filter installation 1 1 NPT female barbed fitting for 1 4 air line for remote mount air filter installation 1 Coiled air line for remote mount air filter installation 1 Air filter housing 1 Replacement air filter elements 1 Wiring harness 1 Toggle switch main in cabin power switch 1 Brake booster bracket Vehicle specific ADA Systems only AUTOMATIC DEPLOYMENT AIR SYSTEMS OPERATING INSTRUCTIONS 1 IMPORTANT Always operate the compressor at or below the MAXIMUM PRESSURE RATING of the compressor Please refer to Application amp Specifications Sections of this manual for details 2 Always observe the MAXIMUM DUTY CYCLE of the air compressor Refer to Compressor Applications and Specifications Sections of this manual for details Operation exceeding maximum pressure ratings and or duty cycle will result in damage to
12. the scale you wish to read PSI BAR KG CM or kPa by pressing the UNIT button Release the trigger anytime during inflation to check tire pressure using the digital gauge 1 USING THE TIRE INFLATION GUN To ensure trouble free service life of your compressor always operate compressor within rated working pressure of the compressor Never use a pressure switch with a higher cut off pressure than compressor s rated working pressure 2 FILLING TIRES AND OTHER INFLATABLE ITEMS Squeeze the Inflation Trigger on the Digital Tire Inflation Gun by pressing it towards the handle of the gun This will allow stored air from the air tank to flow through the gun and through the chuck into your tire or other inflatable 3 CHECKING TIRE PRESSURE To check tire pressure release Inflation Trigger on Digital Tire Inflation Gun while the gauge is turned on Tire pressure will be able to be read properly only when the inflation trigger is released 4 TO TURN UNIT OFF After 15 seconds of non use the unit will turn off on its own 5 STORAGE Always store using the included deluxe carry bag to protect the inflation gun amp hose WARNING Not intended for use with regular portable compressors units meant to be operated with an open ended air chuck The Tire Inflation Gun is equipped with a close ended chuck will hold pressure back Lever Air Chuck Never operate the Digital Tire Inflation Gun at any pressure exceeding 200 PSI
13. ure the harness as needed at several points to avoid abrasion and other possible damage resulting from movement during vehicle use Special care must be taken when routing the harness through sheetmetal to avoid abrasion Make sure that your compressor setup is properly fused by installing the provided fuse in the wiring harness assembly Before connecting to power source re check your system to make sure that all electrical connections are made properly Connect power lead of the wiring harness to the battery It is recommended to provide switched power for the system that is only turned on when the ignition of the vehicle is also energized in case of any air leaks that may allow the system to turn on and drain your battery during periods when the vehicle might remain parked This is especially important when using a small reservoir as is supplied with all ADA Systems Connect the ADA System s Delphi connector to corresponding Delphi plug connector of the wiring harness provided Ensure that the drain valve located on the underside of the ADA System reservoir is closed When power is made available to the ADA system the system will automatically turn on and fill the ADA reservoir When the cutoff pressure of the ADA System has been reached the system will shut off automatically Inspect all air line connections for leaks with soap and water solution If a leak is detected the connection may not be made properly Re do any connection
14. with soap and water solution and tighten Decrease air usage Check all connections with soap and water solution and tighten Replace compressor Replace air filter element Replace pressure switch Replace safety valve Drain tank tilt tank to drain Drain tank more frequently Move compressor to area with less humidity or use air line filter Make sure compressor switch is ON Disconnect compressor s from power source replace fuse Refer to Specifications section for correct amperage rating 3 Let compressors cool off for about 30 minutes to allow thermal overload switch to reset 4 Replace pressure switch 1 Move compressor to well ventilated area or area with lower ambient temperature 2 Repair or replace compressor 1 Tighten bolts 2 Replace bearing or piston assembly 3 Replace piston or compressor CAUTION NEVER DISASSEMBLE COMPRESSOR WHILE COMPRESSOR IS PRESSURIZED USER MANUAL AUTOMATIC DEPLOYMENT AIR SYSTEMS ABOUT COMPRESSOR DUTY CYCLE Compressor Duty Cycle refers to amount of time a compressor can be operated in a given time period at 100 PSI and at a standard ambient temperature of 72 F Duty Cycle is commonly expressed in percentile as Compressor on Time Compressor on Time Off Time As an example a compressor that is rated for 25 duty cycle means that compressor can be operated at 100 PSI 72 F for 10 Minutes ON and 30 Minutes OFF 10 Min On

Download Pdf Manuals

image

Related Search

Related Contents

Owner`s Manual • Manual del usuario • Guide de l`utilisateur  全面6541KB  Manual de Usuario  Canada  pDRIVE< MX eco & pro Serviceanleitung  JOOMLA USER GUIDE (v2.5)  OM, Gardena, Cisailles sur accu, Art 08885-20, Art 08886  Epson PowerLite 1263W  RealStar® Influenza S&T RT-PCR Kit 3.0  取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file