1. cord to the wall socket ifremoved Cold Start When the UPS is OFF and there is no mains power itis possible to power on the essential equipment connected to the UPS outlets Make sure that only the most needed equipmentis connected to the UPS at this time Press the POWER switch to ON position If there is no output and UPS does not go to backup mode then reset the UPS by switching OFF the POWER switch to OFF position Then switch off the unwanted loads connected to the UPS and switch ON the UPS Complete whatever you want to do with the powered equipment before the UPS battery is discharged NOTE This Feature may not work with certain type of loads having high inrush current Alarms Battery Backup During battery backup on battery operation the LED turns Red and the UPS gives an audible alarm consisting of 1 beep repeated after every 20 seconds This alarm stops when the UPS returns to on line operation Battery Low When the UPS is connected to backup mode and the battery goes low the UPS gives a audible alarm consisting of 2 beeps repeated after every 2 seconds Disconnect non essential load equipments from the UPS Save your Data and Shut Down the Computer immediately in order to prevent sudden Shut Down Short Circuit When the UPS gives a continuous audible alarm it means their is short circuit in the load connected Disconnect the load check the short circuit and reconnect with UPS No Load If UPS i
2. load jm E m m Note E7650 IB 8 E2850 IB E21050 IB 1 Do not connect a laser printer to the UPS A laser printer periodically draws significantly more power than when idle and will over load the UPS 2 The UPS output can be used only for electronic loads such as computers 3 In case of fuse blown out please replace the fuse with same type and rating only Caution 1 Nevertouch the contents of fuse or sockets when the mains plug is connected OR the UPS is Switched ON 2 This UPSis designed to operate from 230V 50Hz Sinewave Power Supply available from Electricity Boards No 1101 Power conditioning device like Stabilizer CVT should be connected with the UPS Operation Connect UPS to mains power supply LED shall Blink Green Indicating that the main is normal and Battery is Charging Switch ON the UPS by POWER Switch After the UPS is ON the LED will become Green indicating that the UPS is on Mains and the output is available Now you can switch ON the computer system without worrying about any kind of power interruptions If you wish to test the UPS you may pull out the UPS power cord from wall socket or switch OFF the ON OFF switch of the wall socket And if the computer doesn t shutdown and the LED lights up Red the buzzer starts producing beep sound at an interval of 20 sec It means that the UPS is working in normal condition After doing the above test please ensure to plug in the power
3. 4 hours a day while the backup on battery may only be necessary for less than 1 hour in different slots of time during the day This UPS will help you to protect your sensitive equipment like computers and telecommunication equipment against malfunctioning due to non reliable or distorted mains supply This UPS protects the connected equipment against surges sags spikes etc by means of an internal filter that works all the time During electrical power failures the unit employs its internal maintenance free battery to supply backup power without any interruption This UPS is equipped with many features that will make your equipmentto operate more reliably This UPS is manufactured under ISO 9001 2000 certified quality management process Reliability is built into rugged design by carefully selecting the best components and incorporating advanced technology that offers rock steady output Each UPS subassembly is tested for each and every component used by a state of the art automatic computerised in circuit tester ICT for value and tolerance of components Automated manufacturing technology and the strict quality controls are the foundations for the reliability and consistency common to all our products This model of UPS comes with Two Years Warranty on UPS Electronics amp One Year Warranty on Battery 13 Feature Highlights Optimized SINEWAVE Performance Unlike other UPS this E Series UPS uses Energy Efficiently and th
4. MICROTEK MICROTEK Mn WE LIV MICROTEK TECHNOLOGY WE LIVE E LINE INTERACTIVE UPS 1 YEAR WARRANTY ON BATTERY www microtekdirect com USER S MANUAL MICROTEK TECHNOLOGY WE LIVE Uninterrupted Power Supply Congratulations on selecting Microtek E Series Uninterrupted Power Supply UPS Before installation of this UPS please read this manual carefully to familiarize yourself with all its features indicators and safety precautions SERIES Enjoy the Complete Peace of Mind ENERGY EFFICIENT EF TABLE OF CONTENTS 1 2 3 4 5 6 T 8 9 A O Introduction Feature Highlights Important Precautions Product Package UPS Indicators 8 Controls Connections of the eguipment Installation Operation 8 Alarms Troubleshooting UPS Storage Battery amp Replacing the Battery Technical Specifications Introduction This UPS is specially designed to suit Indian conditions where the voltage can fluctuate to as low as 150 volts 8 as high as 290 volts Keeping this in view this UPS has the extended input voltage range of 145 300 volts so that the UPS gives you the corrected line voltage output of 230 volts 9 and doesn t switch the UPS to Battery Backup mode With this UPS you will enjoy complete peace of mind even when the voltage is too low or too high Do not forget that the UPS has to work for voltage correction for almost 2
5. cting UPS to Mains Ensure that the UPS is supplied Power from a Grounded Socket Only UPS Outlet There are three pieces of standard 5 pin outlet for connecting the AC power cord of the computer A C Fuse This is for protecting the UPS 8 computer connected to the UPS in case excess current is drawn from AC input Ifthe AC fuse is found defective please be sure that it is replaced only by a compatible fuse of the same type 8 size Fuse rating is mentioned below Recommended AC Fuse Rating 8Amp size 5x20mm Fast Blow Type OUTPUT FUSE 8A Installation Connecting the UPS This UPS is equipped to work with power supply with wide voltage range 145 300V AC 50Hz 5 Plug the UPS into a two pole three wire AC wall socket outlet equipped with an earth connection Do not use extension cords Do not plug appliances such as electric heaters toasters and vacuum cleaners into the UPS Do not plug unplug the input cord when the UPS is switched ON Charging the Battery Before initial start first time use it is recommended that the UPS may be connected to mains and battery should be charged for 4 5 hours for optimum use The UPS charges its battery whenever it is connected to mains For best results charge the battery before use Connecting the Loads Plug the loads through the output socket ofthe UPS Now you can switch ON the loads devices as per your requirement UPS suitable for the best
6. e output waveform is optimized to perform like Sinewave Inverter Generator Compatible This E Series UPS has been designed to work with Inverter and Generator This UPS will consider the input from Inverter or Generator as mains and keep providing the Backup to the computer without discharging its own battery No Load Shutdown In case No load is connected to the UPS it will sense the load condition and automatically Shut Down after 3 minutes to protect unnecessary discharge of battery Fast Battery Charging This UPS utilizes unique 5 Step High Frequency Charging Technology to charge the battery in less than 5 hrs in orderto keep your UPS ready immediately for next emergency Extended AVR Range of 145 300 volts When the voltage fluctuates to as low as 150 volts amp as high as 290 volts this UPS gives you the corrected line voltage output of 230 volts 9 and doesn t switch the UPS to Battery Backup mode like most other UPS Over Load Short Circuit Protection If the UPS is excessively overloaded in backup mode or encounters a short circuit it will go into protection mode and warn you to correct the load condition Battery Deep Discharge Over Charge Protection The UPS has in built electronic protection circuit which protects the batteries from getting deep discharged or over charged Important Precautions This UPS has been engineered and manufactured to assure your personal safety but improper use can resul
7. g Battery may need short recharge time or replacement battery lifetime is ending UPS Storage When the UPS is not to be used for a long time the UPS should be charged by connecting to mains power supply for at least 4 5 hours Disconnect the UPS from mains power cover amp store the UPS keeping upright in a cool dry place During long time storage the battery must be charged after every 3 months Store the UPS covered and placed upright in a cool dry place Disconnect all the cables connected to the UPS to avoid unnecessary discharge of the EA battery Make sure that the UPS is switched OFF Battery Replacing the Battery The battery is the most critical part of the UPS as it has to supply the backup Hence the battery must be replaced as soon as you notice that the battery needs replacement Before replacing the battery ensure the following steps 1 The UPS is plugged on in alive wall socket 2 Charge the UPS for at least 4 5 hours 3 Check the Backup on a standard load like 100W Lamp If you don t get proper backup only then proceed to replace the battery Note This UPS contains potentially hazardous voltages Do not attempt to open the UPS when itis connected to the mains Please be sure that all the inlet amp outlet cables are disconnected and the ON OFF switch is in OFF position This unit contains no user serviceable parts Repairs are to be performed by trained service personnel only Dispose off t
8. he old battery properly The battery contains lead and poses a hazard to the environment and human health if not disposed off properly See the instructions with the new battery for more information Battery Replacement The UPS hasan easy to replace battery system 1 Remove 6 Screws on both side panels of the UPS it will separate both the side panels from the back plate 2 Press the UPS down near to front bezel and gently remove the bezel 3 Lay the UPS on one side and remove the side facing up 4 Disconnect the wires connecting the battery batteries to the UPS Loosen the wire by wiggling them while pulling straight back from the battery connector 5 Gently pull the battery batteries out 6 Place the new battery batteries in the UPS carefully avoid punching the wires 7 Connect the new battery batteries in place ofthe old Red wire to Red terminal Black wire to Black terminal Note Small sparks at the battery connections are normal during connection 8 Close the Set and tighten the screws 1131 Technical Specifications MODEL L TER TED E 1050 18 Input Typ 1PC 20 40min Typ 2PC 10 20min Environment Above specifications are measured under computer load Specifications are subject to change without notice E In case of any Customer Support requirement kindly ring up or write to Microtek Branch Service Centre indicating following details i Model Number 8 Serial Nu
9. igned for computer printer and fax only Connecting other equipments may cause the UPS to behave abnormally Do not add equipment that have not been designed for these UPS During a lightning storm unplug the UPS from the wall outlet ON INSTALLATION 1 Donotallow anything to rest on the power cord and do not place the UPS where the power cord is subject to damage 2 Donotuse this UPS near water such as near a bathtub washbowl kitchen sink laundry tub in a wet basement or near a swimming pool 3 This UPS is provided with ventilation openings in the cabinet to allow the release of heat generated during operation If these openings are blocked built up heat can cause failures which may result in a fire hazard Therefore NEVER 1 Block the bottom ventilation slots by placing the UPS on a bed sofa rug etc 2 Place the UPS in a builtin enclosure unless proper ventilation is provided 3 Cover the openings with cloth or other material 4 Place the UPS near or over a radiator or heat source ON CLEANING 1 Unplug and Switch Off the UPS before cleaning the outer surface 2 Useaslightly damp not wet cloth ON RE PACKING 1 Do not throw away the carton and packing materials They make an ideal container in which to pack and transport the unit when shifting the unit to another location Product Package Your Microtek UPS package includes the following items 1 The Microtek UPS with flying in powe
10. mber of the product ii Name amp phone no of the contact person with Location full Address where the product is available and e mail ID if any iii Reported problem description of complaint Note a Refer all servicing queries to Microtek Service Centres only b Please take care that Serial Number is kept intact and that the product is not allowed to be fiddled opened by any unauthorised person otherwise the warranty will be void Service H O Tel 011 42733333 Service E mail for UPS ups microtekdirect com All disputes subject to Delhi jurisdiction only MICROTEK TECHNOLOGY WE LIVE MICROTEK INTERNATIONAL P LTD H 57 Udyog Nagar Rohtak Road New Delhi 110041
11. r cable 2 AC Fuse 8Amp 20mm Fast Blow Type for spares 3 User s Manual ill E7650 IB E7850 IB E21050 IB Note After unpacking inspect the UPS for any damage or any missing item If you find any damaged or missing item immediately notify to the carrier and or to the dealer 171 UPS Indicators and Controls FrontPanel POWER Switch Press the Power Switch to Switch ON the UPS Press the Power Switch again to Switch OFF the UPS LED Indications The LED will light up Green indicating that the UPS is ON and is in Mains Mode The LED Blinks Green indicating that the UPS is OFF and Battery is Charging The LED will light up Red indicating that the UPS is ON and is in Backup Mode The LED Blinks Red with Alarm in case of emergency LED STATUS BUZZER Green Continuous Mains OK Green Blinking UPS OFF Battery Charging Red Continuous Battery Mode 1 Beep every 20 sec Red Blinking Battery Low 2 Beep every 2 sec No Load 1 Beep every 2 sec Short Circuit Continuous Beep sl Overload Rapid Beep POWER SWITCH LED ACTION TO BE TAKEN Switch OFF the UPS if not needed Switch ON the UPS if needed Save Your Data amp Shut Down the Computer Save Your Data amp Quit Immediately Connect load or the UPS will shut down Check load for Short Circuit amp Restart Reduce load Connection of the equipment to UPS Rear Panel Power Cord For conne
12. s ON and No Load is connected to it it will automatically sense the load condition on power failure and wait for 2 minutes and start giving 1 beep repeated after every 2 seconds for 1 minute before shut down Over Load If the UPS is overloaded it will give rapid beep in inverter mode Ensure to remove extra load the beep will automatically stop Trouble Shooting Possible Cause UPS does not turn ON The ON OFF switch is OFF Switch ON the ON OFF switch UPS input circuit Fuse open or Remove the load on UPS Switch Off the UPS 8 Insert missing replace the fuse by one of the same type and rating UPS operates on battery Very high or very low voltage Test if the input voltage is out of range even though line voltage input voltage must be within of the specified AVR exists specified range or has too much distortion Distorted Improper input voltage AC Fuse Blown Also Check the AC Fuse Replace if Blown UPS beeps intermittently Normal UPS operation but no None the UPS is at regular intervals mains voltage present protecting the load UPS buzzer has constant tone UPSis overloaded Remove mains power cord Switch OFF power knob and mains voltage is not present orshortcircuitin battery mode Remove the excess load 8 switch ON the UPS UPS does not provide expected The UPS s battery is weak Charge the battery for 4 5 hours If the backup is backup time due to recent usage and a insufficient after rechargin
13. t in electrical shock or fire hazard In order to achieve the safeguards incorporated in this UPS observe the following basic rules of safety installation cleaning and repacking ONSAFETY ls 2 3 Operate the UPS only from a power source mentioned in the technical information of this manual Refer Section 7 The equipment must be earthed at all times while in use Do not plug UPS s power cord into itself which will result in a safety hazard Overloaded AC outlets and extension cords are dangerous so are frayed power cables and broken plugs They may result in a shock or fire hazard call your service technician for replacement DO NOT OPEN THE UPS There are no user serviceable components inside There are dangerous high voltages inside even when the power is off Contact your authorised dealer if the UPS is not operating properly Do not put the UPS under the Sun directly to avoid any possibility of damage Replace battery and fuse only with the same type and rating To avoid personal injury Do not place the UPS on a sloping shelf unless properly secured Use a perfect stand to hold the UPS To prevent fire Hazards Always turn the UPS OFF when you leave the room for more than a short period of time Never leave the UPS ON when leaving the house Keep children away from dropping or pushing objects into the UPS s cabinet openings Some internal parts carry hazardous voltages This UPS is des
Download Pdf Manuals
Related Search
Related Contents
ChemStation Agilent - Agilent Technologies Tender Document - Oil India Limited Bedienungsanleitung Ex geschützte Taschenlampe KS-9800 English - Siqura Samsung M628 用戶手冊 1.47MB Sigma PC 9 Man PortMaster® 4 User Manual Addendum Tuteur mode d`emploi - Académie de Montpellier Copyright © All rights reserved.