Home

TDS1000 and TDS2000 Series User Manual Specifications Update

image

Contents

1. New Zealand Declaration of Conformity EMC EMC Compliance FCC Compliance Russian Federation Peoples Republic of China EC Declaration of Conformity Low Voltage U S Nationally Recognized Testing Laboratory Listing Canadian Certification Additional Compliance Complies with EMC provision of Radiocommunications Act per these stan dard s m AS NZS 2064 1 2 Industrial Scientific and Medical Equipment 1992 Meets the intent of Directive 89 336 EEC for Electromagnetic Compatibility when it is used with the product s stated in the specifications table Refer to the EMC specification published for the stated products May not meet the intent of the directive if used with other products Emissions comply with FCC 47 CFR Part 15 Subpart B for Class A equipment This product was certified by the GOST ministry of Russia to be in compliance with all applicable EMC regulations This product has received the Chinese Metrology Certification CMC Compliance was demonstrated to the following specification as listed in the Official Journal of the European Communities Low Voltage Directive 73 23 EEC amended by 93 68 EEC m EN 61010 1 2001 Safety requirements for electrical equipment for measurement control and laboratory use m EN 61010 2 031 2002 Particular requirements for handheld probe assem blies for electrical measurement and test equipment m UL 61010B 1 2004 2nd Edition Standard for electrical measu
2. avoid release of such substances into the environment and to reduce the use of natural resources we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropriately The symbol shown to the left indicates that this product complies with the European Union s requirements according to Directive 2002 96 EC on waste electrical and electronic equipment WEEE For information about recycling options check the Support Service section of the aa Tektronix Web site www tektronix com Mercury Notification This product uses an LCD backlight lamp that contains mercury Disposal may be regulated due to environmental considerations Please contact your local authorities or within the United States the Electronics Industries Alliance www eiae org for disposal or recycling information This product has been classified as Monitoring and Control equipment and is outside the scope of the 2002 95 EC RoHS Directive This product is known to contain lead cadmium mercury and hexavalent chromium TDS1000 and TDS2000 Series User Manual Specifications Update 1 Specifications Update Specifications Update The next table shows specifications for the new TDS1001 and TDS2004 models and includes three corrections These specifications supersede the corresponding specifications in the TDS1000 and TDS2000 series oscilloscope user manual The corrections are for the fol
3. S2000 series oscilloscope specifications cont Trigger Trigger Sensitivity Coupling Edge Trigger Type Sensitivity TDS1001 TDS1002 TDS1012 TDS2022 TDS2024 TDS2002 TDS2004 TDS2012 TDS2014 200 mV from DC to 100 MHz 200 mV from DC to 100 MHz 350 mV from 100 MHz to 200 MHz 1 V from DC to 100 MHz 1 V from DC to 100 MHz 1 75 V from 100 MHz to 200 MHz CH1 CH2 1 div from DC to 10 MHz 1 5 div from 10 MHz to Full CH3 CH4 Not Equal Guardband t gt 330 ns 5 lt guardband lt 5 1 16 5 ns 165 ns lt t lt 330 ns guardband 16 5 ns 33 ns t lt 165 ns guardband 16 5 ns Bandwidth reduced to 6 MHz with a 1X probe Certifications and Compliances EN 61326 EMC requirements for Class A electrical equipment for measurement control and laboratory use Annex D EN 61000 3 2 AC power line harmonic emissions IEC 61000 4 2 Electrostatic discharge immunity IEC 61000 4 3 RF electromagnetic field immunity IEC 61000 4 4 Electrical fast transient burst immunity IEC 61000 4 5 Power line surge immunity IEC 61000 4 6 Conducted RF Immunity IEC 61000 4 11 Voltage dips and interruptions immunity 1 EN 61000 3 3 Voltage changes fluctuations and flicker 1 Emissions which exceed the levels required by this standard may occur when this equipment is connected to a test object TDS1000 and TDS2000 Series User Manual Specifications Update Specifications Update Australia
4. S2022 TDS2024 40 MHz t 60 MHz t Sample and Average modes at BNC or with P2220 probe DC Coupled Analog Bandwidth in Peak Detect mode 50 s div to 5 us div4 typical 20 MHz when vertical scale is set to lt 5 mV TDS1001 TDS1002 TDS2002 TDS2004 30 MHz t 50 MHz t 20 MHz when vertical scale is set to lt 5 mV 100 MHz t 200 MHz t 0 C to 40 C 32 F to 104 F 160 MHz t 0 C to 50 C 32 F to 122 F TDS1012 TDS2012 TDS2014 TDS2022 TDS2024 75 MHz t Rise Time at BNC 7DS1001 TDS1002 TDS2002 TDS2004 TDS1012 TDS2012 TDS2014 TDS2022 TDS2024 typical Horizontal Sample Rate Range SEC DIV Range lt 84ns lt 5 8ns TDS2022 TDS2024 5 S s to 2 GS s TDS2022 TDS2024 2 5 ns div to 50 s div in a1 2 5 5 sequence Bandwidth reduced to 6 MHz with a 1X probe When vertical scale is set to 5 mV lt 3 5ns lt 2 1ns TDS1001 TDS1002 TDS1012 TDS2002 TDS2004 TDS2012 TDS2014 5 S s to 1 GS s TDS1001 TDS1002 TDS1012 TDS2002 TDS2004 TDS2012 TDS2014 5 ns div to 50 s div in a 1 2 5 5 sequence The oscilloscope reverts to Sample mode when the SEC DIV horizontal scale is set from 2 5 us div to 5 ns div on 1 GS s models or from 2 5 us div to 2 5 ns div on 2 GS s models The Sample mode can still capture 10 ns glitches TDS1000 and TDS2000 Series User Manual Specifications Update Specifications Update Updates for the TDS1000 and TD
5. Supplement Tektronix TDS1000 and TDS2000 Series User Manual Specifications Update 071 1858 00 www tektronix com UAT AC AN A 071185800 Copyright Tektronix Inc All rights reserved Licensed software products are owned by Tektronix or its subsidiaries or suppliers and are protected by national copyright laws and international treaty provisions Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supercedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc Contacting Tektronix Tektronix Inc 14200 SW Karl Braun Drive P O Box 500 Beaverton OR 97077 USA For product information sales service and technical support m In North America call 1 800 833 9200 m Worldwide visit www tektronix com to find contacts in your area BS 4a eee Environmental Considerations Product End of Life Handling Restriction of Hazardous Substances This section provides information about the environmental impact of the product Observe the following guidelines when recycling an instrument or component Equipment Recycling Production of this equipment required the extraction and use of natural resources The equipment may contain substances that could be harmful to the environment or human health if improperly handled at the product s end of life In order to
6. a temporary conductivity that is caused by condensation must be expected This location is a typical office home environment Temporary condensation occurs only when the product is out of service Pollution Degree 3 Conductive pollution or dry nonconductive pollution that becomes conductive due to condensation These are sheltered locations where neither temperature nor humidity is controlled The area is protected from direct sunshine rain or direct wind Pollution Degree 4 Pollution that generates persistent conductivity through conductive dust rain or snow Typical outdoor locations Pollution Degree 2 as defined in IEC 61010 1 Note Rated for indoor use only Terminals on this product may have different installation overvoltage category designations The installation categories are Measurement Category IV For measurements performed at the source of low voltage installation Measurement Category III For measurements performed in the building installation Measurement Category II For measurements performed on circuits directly connected to the low voltage installation Measurement Category I For measurements performed on circuits not directly connected to MAINS Overvoltage Category II as defined in IEC 61010 1 TDS1000 and TDS2000 Series User Manual Specifications Update
7. lowing specifications m Channel to Channel Common Mode Rejection typical m Trigger Sensitivity Edge Trigger Type m Not Equal Guardband NOTE All Vertical specifications are relative to a 1X probe To modify displayed values change the Probe option attenuation default is 10X to match the probe Updates for the TDS1000 and TDS2000 series oscilloscope specifications Inputs Channel to Channel TDS1001 TDS1002 TDS2002 TDS2004 TDS1012 TDS2012 TDS2014 TDS2022 TDS2024 comro n 100 1 at60Hz 100 1 at 60 Hz 100 1 at 60 Hz ejection typ 20 1 at 20 MHz 20 1 at 30 MHz 10 1 at 50 MHz Measured on MATH Ch1 Ch2 waveform with test signal applied between signal and common of both channels and with the same VOLTS DIV and coupling settings on each channel Measured on MATH Ch Ch4 waveform for 4 channel models Channel to Channel 7DS1001 TDS1002 TDS2002 TDS2004 TDS1012 TDS2012 TDS2014 TDS2022 TDS2024 Crosstalk gt 100 1 at 20 MHz 100 1 at 30 MHz gt 100 1 at 50 MHz gt 100 1 at 100 MHz Measured on one channel with test signal applied between signal and common of the other channel and with the same VOLTS DIV and coupling settings on each channel TDS1000 and TDS2000 Series User Manual Specifications Update Specifications Update Updates for the TDS1000 and TDS2000 series oscilloscope specifications cont Vertical Analog Bandwidth in TDS1001 TDS1002 TDS2002 TDS2004 TDS1012 TDS2012 TDS2014 TD
8. ring and test equipment m UL 61010B 2 031 2003 Particular requirements for handheld probe assemblies for electrical measurement and test equipment m CAN CSA C22 2 No 1010 1 1997 Particular requirements for electrical equipment for measurement control and laboratory use Part 1 m CAN CSA C22 2 No 61010 2 031 1994 Particular requirements for handheld probe assemblies for electrical measurement and test equipment m IEC 61010 1 2001 Safety requirements for electrical equipment for measurement control and laboratory use TDS1000 and TDS2000 Series User Manual Specifications Update 5 Specifications Update Equipment Type Pollution Degree Descriptions Pollution Degree Installation Overvoltage Category Descriptions Overvoltage Category IEC 61010 031 2002 Particular requirements for handheld probe assemblies for electrical measurement and test equipment Test and measuring equipment A measure of the contaminates that could occur in the environment around and within a product Typically the internal environment inside a product is considered to be the same as the external Products should be used only in the environment for which they are rated Pollution Degree 1 No pollution or only dry nonconductive pollution occurs Products in this category are generally encapsulated hermetically sealed or located in clean rooms Pollution Degree 2 Normally only dry nonconductive pollution occurs Occasionally

Download Pdf Manuals

image

Related Search

Related Contents

      Handbuch  VisCad User Guide  SEPTOL™ EMPREINTES  2 jours  HYDRAULIC BULL NOSE GRINDER  12-18-25- 38-50/CNS 12-18-25-38-50/FN 7-12-18-25-38  User Manual ConfigPro 1.4 WinPro ® Configuration  

Copyright © All rights reserved.
Failed to retrieve file