Contents

1. 14 Setting the Sound On OFF Checking the System Control Solution Testing Comparing the Control Solution Test Results 21 Testing Using the Lancing Device Preparing the Lancing Device Preparing the Meter and Test Strip Marking Post meal Test Results Applying Blood Sample Discarding Used Lancets Alternative Site Testing Hl and Lo Messages Target Blood Glucose Ranges Transferring Test Results Additional Functions Meter Memory 35 Setting the Post meal Alarm PP2 alarm 38 Maintenance Understanding Error and Other Messages 39 General Troubleshooting Performance Characteristics Warranty Information Welcome to the TEE2 Blood Glucose Monitoring System Thank you for choosing
2. hyperosmolar state with or without ketosis Critically ill patients should not be tested with blood glucose meters Inaccurate results may occur in patients undergoing oxygen therapy If you need assistance please contact the Spirit Healthcare 24 7 Freephone Support Line at 0800 881 5423 or go to www Spirit healthcare co uk www spirit healthcare co uk 5 Specifications TEE2 Blood Glucose Monitoring System e Product specifications Reported result range 1 1 33 3 mmol L Sample size Minimum 0 5 uL Test time 5 seconds Sample type Fresh capillary whole blood Calibration Plasma equivalent Assay method Electrochemical Battery life 5 000 tests Power Two 3 0 V lithium batteries disposable type CR2032 Memory 500 test results Size 90 X 48 5 X 14 mm Weight 50 1 g with batteries Operating ranges Temperature 5 50 C 41 122 F Relative humidity 10 9096 Hematocrit 20 6096 6 www i sens com Components TEE2 Blood Glucose Meter TEE2 Blood Glucose Test Strips 10 Owner s Booklet Quick Reference Guide Logbook Lancing Device Lancets 10 Batteries 2 Carrying Case Certain components may not be included depending on the place of purchase e Check all the components after opening the TEE2 blood glucose monitoring system package The exact contents are listed on the main box www spirit healthcare co uk 7 In
3. 35 1 511 S63 www spirit healthcare co uk 33 Transferring Test Results Meter Memory Test results stored in TEE2 meter can be transferred from the meter to a computer using data management software and cable The Pc is displayed when the data cable connects the meter with a computer For more information contact the Spirit Healthcare 24 7 Freephone Support Line at 0800 881 5423 or go to www spirit healthcare co uk 34 www i sens com The TEE2 Meter can save up to 500 glucose test results with time and date If the memory is full the oldest test result will be deleted and the latest test result will be stored The TEE2 Meter calculates and displays the averages of total test results pre meal test results and post meal test 11 results from the last 1 7 14 30 and 90 days Viewing Test Results Stored in the Meter s Memory Step 1 Press the C or M button to turn the meter on The current date and time will be displayed on the bottom of the screen for 2 seconds followed by the average value and the number of the test results saved within the current day The number of tests within the current day Step 2 Press the C to view 7 14 30 and 90 day average values and the number of tests performed for the last test period ay Cp C button Average Li Li 1 7 14 30 am ben 90 days oo mmol L On En M button www spirit healthcare co uk 35 Step 3 Repeatedly press th
4. TEE2 Owner s Booklet product packaging and product inserts CE BERN bt e For in vitro diagnostic use This product fulfills the requirements for Directive 98 79 EC on in vitro diagnostic medical devices Cautions for safety and optimum product use Consult instruction for use Do not discard this product with other household type waste Use by unopened or opened test strip vial Manufacturer X Temperature limitations Do not reuse Batch code Serial number Authorised representative 4 www i sens com The TEE2 Blood Glucose Monitoring System is intended for self testing outside the body in vitro diagnostic use The glucose in the blood sample mixes with special chemicals on the test strip to produce a small electrical current The TEE2 meter detects this electrical current and measures the amount of glucose in the blood sample The TEE2 Blood Glucose Meter is designed to minimise code related errors in monitoring by using the no coding function The TEE2 Blood Glucose Meter should be used only with the TEE2 Strip An abnormally high or low red blood cell count hematocrit level over 6096 or below 2096 may produce inaccurate results If your test result is below 3 3 mmol L or above 13 3 mmol L consult a healthcare professional immediately Inaccurate results may occur in severely hypotensive individuals or patients in shock Inaccurate low results may occur for individuals experiencing a hyperglycaemic
5. accurate value Press and hold C A number indicating the month will be to scroll faster blinking on the left corner of the screen To confirm all settings press and hold the M button and the Press C button until the correct month screen will switch off appears Press the M button to confirm your selection and progress to setting the date Adjusting the Date and Time Step 1 Entering the SET Mode Press the M button while the meter is switched off The SET character will be displayed on the screen Press the M button again to progress to setting the year Step 4 Setting the Date Press C button until the screen displays the correct date Press the M button to confirm the date and progress to setting the time Step 2 Setting the Year Press and release C button to adjust until the correct year appears Press and hold C button to scroll through the numbers quickly After setting the year press the M button to confirm your selection and progress to setting the month Step 5 Setting the Time The meter can be set in the AM PM 12 hour or the 24 hour clock format Press C button to select a format The AM PM symbol is not displayed in the 24 hour format After selecting the format press the M button to progress to setting the hour 14 www i sens com www spirit healthcare co uk 15 Step 6 Setting the Hour Press C button until the correct hour appears After the hour is set press the M button to progress to sett
6. an extended period of time e Do not let dirt dust blood or water enter into the meter s test strip port Donotdrop the meter or submit it to strong shocks Donottry to fix or alter the meter in any way Strong electromagnetic radiation may interfere with the proper operation of this device Keep the device away from sources of strong electromagnetic radiation especially when measuring your blood glucose TEE2 meter should be used only with TEE2 strips Keep the meter in a cool and well ventilated place Store all the meter components in the portable case to prevent loss and help keep the meter clean www spirit healthcare co uk 9 TEE2 Blood Glucose Test Strip The TEE2 blood glucose monitoring system measures blood glucose quickly and accurately It automatically absorbs the small blood sample applied to the narrow edge of the strip Contact bars Gently push the test strip with its contact bars facing up into the test strip port of meter t l6 Insert Confirmation window Check here to see whether sufficient blood sample has been applied Edge to apply blood sample Apply blood sample here for testing 10 www i sens com Warning e TheTEE2 Test Strip should be used only with fresh capillary whole blood samples e Do not reuse test strips e Do not use test strips past the expiration date Test strips in new unopened vials and test strips in vials that have been opened c
7. e Ifyou drop or damage the meter Control Solution Testing Step 1 Insert a test strip into the meter s test strip port with the contact bars facing upwards Gently push the test strip into the port until the meter beeps Be careful not to bend the strip A while pushing it in The 4 symbol will be displayed on the screen Step 2 d Shake the TEE2 Control Solution bottle before each test Remove the cap and squeeze the bottle to discard the first drop Then n illl wipe the tip with a clean tissue or MI II ei cloth After the 4 symbol appears on the display apply the solution to the narrow edge of the test strip until the meter beeps Make sure the confirmation window fills completely Note The meter may switch off if the control solution sample is not applied within 2 minutes of the amp symbol appearing on the screen If the meter turns off remove the strip reinsert and start from step 1 www spirit healthcare co uk 19 Step 3 A test result will appear after the meter counts down from 5 to 1 After your control solution result appears on the display press C for 3 seconds till the check symbol appears on the display When the check symbol is displayed the result is stored in the meter s memory but it will not be included in the averages Step 4 Compare the result displayed on the meter to the range printed on the test strip vial The result should fall within that range Used st
8. just before applying the blood sample Once you attach the post meal mark ff to the test results it cannot be deleted Step 7 If you want to attach a post meal mark 11 to a test result press and hold C for 3 seconds after inserting the test strip The post meal mark 1f and the 4 symbol will appear on the screen The test result will also be displayed with the post meal mark fl If you do not want to save the result as a post meal test move on to step 8 after step 6 www spirit healthcare co uk 25 Applying Blood Sample Step 8 Obtain a blood sample using the lancing device Place the device against the pad of the finger The best puncture sites are on the middle or ring fingers Press the release button Remove the device from the finger Wait a few seconds for a blood drop to form A minimum volume of 0 5 microliter is needed to fill the confirmation window Actual size of 0 5 uL e Step 9 After the 4 symbol appears on the screen apply the blood sample to the narrow end of the test strip till the meter beeps If the confirmation window is not filled in time because of abnormal viscosity thickness and stickiness or insufficient volume the Er4 message may appear Itis recommended that the application of blood sample to the test strip be performed virtually vertical to the sample site as shown in the diagram below i CH Good Sample Insufficient Sample 26 www i sens
9. the TEE2 Blood Glucose Monitoring System The system provides you with safe fast and convenient blood glucose in vitro i e outside the body diagnostic monitoring You can obtain accurate results in just 5 seconds with a small 0 5 uL blood sample No part of this document may be reproduced in any form or by any means without the prior written consent of i SENS The information in this manual is correct at the time of printing However i SENS reserves the right to make any necessary changes at any time without notice as our policy is one of continuous improvement Important Information Read this First Important Information To receive safe and optimum system benefits please read the entire manual contents before using the system Please note the following instructions Intended use TEE2 Blood Glucose Monitoring System is used for the quantitative measurement of the glucose level in capillary whole blood as an aid in monitoring diabetes management effectively at home or in clinical settings TEE2 Blood Glucose Monitoring System should be used only for self testing outside the body in vitro diagnostic use only A TEE2 Blood Glucose Monitoring System should not be used for the diagnosis of diabetes or for testing newborns Testing sites include the traditional fingertip testing along with alternate sites testing on forearm palm thigh and calf The following chart explains the symbols you ll find in the
10. 0 56 mmol L Within 0 83 mmol L 11 11 100 11 11 100 11 11 10096 Accuracy results for glucose concentration 2 4 2 mmol L Within 5 Within x 1096 Within 1596 Within 20 47 111 42 89 111 80 109 111 9896 111 111 100 42 www sens com Precision The precision studies were performed in a laboratory using TEE2 BGM Systems Within Run Precision Blood avg 2 3 mmol L SD 0 1 mmol L Blood avg 4 4 mmol L SD 0 2 mmol L Blood avg 7 2 mmol L CV 2 6 Blood avg 11 2 mmol L CV 3 196 Blood avg 19 4 mmol L CV 2 796 Total Precision Control avg 2 0 mmol L SD 0 07 mmol L Control avg 6 5 mmol L CV 2 396 Control avg 17 9 mmol L CV 2 496 This study shows that there could be variation of up to 3 196 www spirit healthcare co uk 43 Warranty Information i SENS Inc warrants that the TEE2 Meter shall be free of defects in material and workmanship in normal use for a period of five 5 years The meter must have been subjected to normal use The warranty does not cover improper handling tampering use or service of the meter Any claim must be made within the warranty period The i SENS company will at its discretion repair or replace a defective meter or meter part that is covered by this warranty As a matter of warranty policy i SENS will not reimburse the consumer s purchase price Obtaining
11. SPIRT HEALTHCARE Spirit Healthcare Ltd Spirit House Selbury Drive Oadby Leicester LE2 5NG Customer Support Tel 0800 881 5423 www spirit healthcare co uk 24 7 NON AUTOMATED FREE SUPPORT 0800 881 5423 i SENS Inc ner Medical Technology Promedt 27 36 Gwangun ro Nowon gu Consulting GmbH Seoul 139 845 Korea Altenhofstrasse 80 D 66386 www i sens com St Ingbert Germany 0 2015 i SENS Inc All Rights Reserved PGC8E3060 REVO 03 2015 Cas e I Sens Owner s Booklet TEE Blood Glucose Monitoring System No Ly Coding Easy amp Accurate Testing 054 0 Very Small Sample actual size shown sa b Rapid Test Result sPin r HEALTHCARE Table of Contents Information Important Information Read this First Specifications TEE2 Blood Glucose Monitoring System 7 Inserting or Replacing the Batteries 8 Caring for Your System TEE2 Blood Glucose Test Strip TEE2 Blood Glucose Meter TEE2 Blood Glucose Meter Display 13 Preparation Setting up Your System 14 Adjusting the Date and Time
12. Warranty Service To obtain warranty service you must return the defective meter or meter part along with proof of purchase to your nearest Spirit Healthcare Please contact Customer Support on 0800 881 5423 for further information 44 www i sens com
13. an be used up until the expiration date printed on the test strip box and vial label if the test strips are used and stored according to its storage and handling methods Store test strips in a cool and dry place at a temperature of 1 30 C 34 86 F e Keep test strips away from direct sunlight or heat and do not freeze Store test strips only in their original vial e Close the vial tightly after taking out a test strip for testing and use the strip immediately Handle test strips only with clean and dry hands Do not bend cut or alter test strips in any way e For detailed storage and usage information refer to the TEE2 Test Strip package insert Caution Keep the meter and testing supplies away from young children The test strip vial contains drying agents that are harmful if inhaled or swallowed and may cause skin or eye irritation www spirit healthcare co uk 11 TEE2 Blood Glucose Meter TEE2 Blood Glucose Meter Display Data Port Used to transfer data from the meter to a computer with the cable available from your authorised i SENS representative alarm mem j j check Display Shows results messages mmol L mg dL 88 88 88 88 5 M Button C Button Turns the meter Selects or on off and changes confirms information menu selections Test Strip Port Insert test strip here Note The cable for data management software can be ordered separately Please contact your au
14. ays results between 1 1 33 3 mmol L HI appears when the blood glucose level is greater than 33 3 mmol L and indicates severe hyperglycaemia much higher than normal glucose levels If HI symbol is displayed again on retesting please contact your healthcare professional immediately Lo Message Lo appears when a test result is less than 1 1 mmol L and indicates severe hypoglycaemia very low glucose levels m If Lo symbol is displayed again on retesting please contact your healthcare professional A Gm immediately mmol L 9 04 1 9 Note Please contact the Spirit Healthcare 24 7 Freephone Support Line at 0800 881 5423 or go to www spirit healthcare co uk if such messages are displayed even if you do not have hyperglycaemia or hypoglycaemia 32 www i sens com Reminders Your target ranges Time of day from your healthcare professional Before breakfast Before lunch or dinner 1 hour after meals 2 hours after meals Between 2 a m and 4 a m Expected Values The range of a normal fasting blood glucose level for non diabetic adults is between 3 9 5 5 mmol L Two 2 hours after a meal the range of a normal blood glucose level for non diabetic adults is between 5 6 7 7 mmol L Fasting is defined as no caloric intake for at least eight 8 hours Reference American Diabetes Association Standards of Medical Care in Diabetes 2012 Diabetes Care January 2012
15. com Note The meter may switch off if the blood sample is not applied within 2 minutes of the amp symbol appearing on the screen If the meter turns off remove the strip reinsert it and apply blood sample after amp symbol appears on the screen Step 10 The test result will appear after the meter counts down from 5 to 1 The result will be automatically stored in the meter s memory If the test strip is removed after the test result is displayed the meter will automatically switch off after 3 seconds Discard used test strips safely in disposable containers www spirit healthcare co uk 27 Alternative Site Testing Discarding Used Lancets Step 1 Unscrew lancing device tip Step 2 Place protective cover on lancet Push the lancet ejector forward with the thumb and simultaneously pull out the sliding barrel to dispose of the used lancet in a proper biohazard container Caution The lancet is for single use only Never share or reuse a lancet Always dispose of lancets properly 28 www sens com What is AST Alternative Site Testing Usually when someone tests their glucose they take the blood sample from the tip of the finger However since there are many nerve endings distributed there it is quite painful When doing a glucose test using different parts of the body such as the forearms palms thighs and calves can reduce the pain during testing This meth
16. e C to view 1 7 14 30 and 90 day average value and the number of tests performed pre meals with the Pr symbol for the last test period Cbutton i Pre meal c c average 1 7 14 30 A A 90 days d te UD en Step 4 Press the Cto view 1 7 14 30 and 90 day average values and the number of tests performed post meals with the ff symbol for the last test period C button pun Pre meal n E average 1 7 14 30 L Ll A 90 days x ni M button m gn AVG 03 3n Y DAY n D V ovo LILI Ja Step 5 Use the M button to scroll back through the averages seen previously Press the M button for 3 seconds to turn the meter off 36 www i sens com Note The control solution test results saved with check symbol are not included in the averages The control solution test results saved with check symbol will be displayed with check symbol when you review the stored test results Viewing Test Results Stored in the Meter s Memory Step 1 Press the C or M button to turn the meter on The current date and time will be displayed on the bottom of the screen for 2 seconds followed by the 1 day average value and the number of the test results saved within Thenumberoftests the current day within the current day Step 2 Use the M button to scroll through the test results starting from the most recent and ending with the oldest Press the C to return to the result seen previously Afte
17. he strip has been inserted completely into the test strip port Check if the appropriate test strip was used Check whether the batteries are inserted with the side facing up Replace the batteries The test does not start even after applying the blood sample on the strip Check if the confirmation window is filled completely Repeat the test after inserting a new test strip The test result doesn t Repeat the test after inserting a new test strip match the way you Check the expiration date of the test e Perform control solution test Note e If the problem is not resolved please contact the Spirit Healthcare 24 7 Freephone Support Line at 0800 881 5423 or go to www spirit healthcare co uk www spirit healthcare co uk 41 Performance Characteristics The performance of TEE2 Blood Glucose Monitoring System has been evaluated in laboratory and in clinical tests Accuracy The accuracy of the TEE2 BGM System Model GM505KAB GM505KBB was assessed by comparing blood glucose results obtained by patients with those obtained using a YSI Model 2300 Glucose Analyser a laboratory instrument The following results were obtained by diabetic patients at clinic centres Slope 1 02 Y intercept 0 41 mmol L Correlation coefficient r 0 992 Number of sample 122 Range tested 2 2 32 1 mmol L Accuracy results for glucose concentration 4 2 mmol L Within 0 28 mmol L Within
18. ing properly ZS The test strip vials have TEE2 Control Solution ranges printed on their labels Compare the result displayed On the meter to the TEE2 Control Solution range printed on the test strip vial Before using a new meter or a new vial of test strips you may conduct a control solution test following the procedure on pages 19 20 Notes e Use only the TEE2 Control Solution available for purchase separately e Check the expiration dates printed on the bottle When you first open a control solution bottle record the discard date date opened plus three 3 months in the space provided on the label Make sure your meter test strips and control solution are at room temperature before testing Control solution tests must be done at room temperature 20 25 C 68 77 F Before using the control solution shake the bottle discard the first few drops and wipe the tip clean e Close the control solution bottle tightly and store at a temperature of 8 30 C 46 86 F You may do a control solution test e When you want to practice the test procedure using the control solution instead of blood e When using the meter for the first time Whenever you open a new vial of test strips e Ifthe meter or test strips do not function properly e If your symptoms are inconsistent with the blood glucose test 18 www i sens com results and you feel that the meter or test strips are not working properly
19. ing the minute Step 7 Setting the Minute Press C button until the correct minute appears After setting the minute press the M button to progress to setting the sound 16 www i sens com Setting the Sound On OFF Step 8 On pressing C button the screen will display the On or OFF Press the M button to confirm the selection The meter will beep in the following instances if set to On When the test strip is inserted in the meter When the blood sample is absorbed into the test strip and the test starts When the test result is displayed When you push the M button or C button to turn on the meter When you push the C button to set the post meal PP2 alarm When it is time for a preset blood glucose test If the sound is set to OFF none of the sound functions will work To confirm all settings press and hold the M button and the screen will switch off Note Only when the sound is set to OFF ON symbol appears on the display At any stage if the M button is pressed for 3 seconds Time and Date setting mode will finish and the meter will be turned off Press and hold C to scroll through numbers quickly www spirit healthcare co uk 17 Checking the System You may check your meter and test strips using the TEE2 Control Solution control A and or B Bi The TEE2 Control Solution contains a known amount of glucose and is used to check that the meter and the test strips are work
20. od of testing with different parts of the body is called Alternative Site Testing While AST may reduce the pain during testing it may not be simple for everyone and the following precautions should be observed during testing Alternative Sites for Testing Alternative Site Blood Sampling forearm palm thigh calf Select a clean soft and fleshy sample site area free of visible veins and hair and away from bones Gently massage the sample site to help blood circulation to minimize result differences between fingertip and alternative site sampling Firmly press and hold the lancing device against site Wait until the skin surface under the lancing device changes color Then press the release button while continuing to apply pressure Keep holding the lancing device against your skin until sufficient at least 0 5 uL actual size e blood is drawn Carefully lift the lancing device away from your skin www spirit healthcare co uk 29 Things to know when using AST Please understand the following before testing at alternative sites forearms palms thighs and calves The capillary whole blood of the fingertips shows changes in glucose levels more rapidly than in alternative sites Therefore the test results from the fingertip test and AST may differ This is because things such as lifestyle and ingested food have an effect on glucose levels Acceptable situations for AST When your blood glucose levels are stable e Fas
21. oughly Step 2 Unscrew and remove the lancing device tip Step 3 Firmly insert a new lancet into the lancet holder Hold the lancet firmly Gently twist to pull off protective disk Save disk to recap lancet after use Replace lancing device tip www spirit healthcare co uk 23 Step 4 Select a desired depth of one to five 1 5 on the lancing device s adjustable tip Choose a depth by rotating the top portion of the adjustable tip until the setting number matches the arrow A beginning setting of three 3 is recommended Step 5 To cock the lancing device hold the body of lancing device in one hand Pull the sliding barrel with the other hand The lancing device is cocked when you feel a click Note The skin depth to get blood samples will vary for various people at different sample sites The lancing device s adjustable tip allows the best depth to get an adequate sample size A beginning setting of three 3 is recommended 24 www sens com Preparing the Meter and Test Strip Step 6 Insert a test strip with the contact bars facing upwards into the meter s test strip port Push the strip in gently until the meter beeps Be careful not to bend the test strip The amp symbol will appear on the screen B Marking Post meal Test Results The TEE2 meter allows you to mark a result of a post meal test with ff symbol The post meal test mark 11 can be attached
22. r checking the stored test result press the M button to turn off the meter mani Cbutton eu lt D a mmol L 03 08 18 03 ee i 08 38 4u amp M button www spirit healthcare co uk 37 Setting the Post meal Alarm PP2 alarm Understanding Error and Other Messages The PP2 alarm goes off 2 hours after setting the alarm The alarms ring for 15 seconds and can be silenced by pressing C or the M button or by inserting a test strip Step 1 Setting the PP2 alarm On Without inserting a test strip press and hold C for 3 seconds to set the post meal alarm The PP2 character the alarm symbol and then the On character will be displayed The screen will then automatically change to the memory check mode At this time the alarm symbol indicating that the PP2 alarm has been set will be displayed on the screen o m mmol L mmol L On GS Qu 01 09 5n Step 2 Setting the PP2 alarm OFF To turn off the PP2 alarm press and hold C for 3 seconds The PP2 character the alarm symbol and then the OFF character will appear on the screen Then the screen will change automatically to the memory check mode without the alarm symbol being displayed DD A mmol L GFF 05 Om alarm disappears D 0 Jalg mmol L 01 095a 38 www i sens com Message What It Means What To Do A used test strip was inserted Repeat the test with a new test s
23. rips should be discarded safely in disposable containers Control Solution Range Control A 5 6 8 4 mmol L Control B 10 2 15 3 mmol L LoT 8 Caution The range printed on the test strip vial is for the TEE2 Control Solution only It does not have any connection to your blood glucose level Note The TEE2 Control Solution can be purchased separately Please contact Spirit Healthcare on 0800 881 5423 20 www sens com Comparing the Control Solution Test Results The test result of each control solution should be within the range printed on the label of the test strip vial Repeat the control solution test if the test result falls outside of this range Out of range results may occur due to the following factors e When the control solution bottle was Repeat the not shaken well control solution e When the meter test strip or the control test by referring solution were exposed to high or low to the Notes temperatures on page 18 When the first drop of the control solution was not discarded or the tip of the bottle was not wiped clean e When the meter is not functioning properly e When the control solution is past the expiration date printed on the bottle e When the control solution is past its discard date the date the bottle was opened plus three 3 months When the control solution is contaminated Discard the used control solution and repea
24. serting or Replacing the Batteries Caring for Your System The TEE2 Meter comes with two 3 0 V lithium batteries Before using the meter check the battery compartment and insert batteries if empty When using your meter and seeing the mm symbol appear on the display for the first time the batteries should be replaced as soon as possible The test results might not be saved if the batteries run out Step 1 Make sure the meter is turned off Push the cover in the direction of the arrow to open the battery compartment Step 2 Remove the old batteries one by one by lifting with the index finger and pulling it S out with your thumb and index fingers as b shown in the figure on the right Insert two new batteries with the side facing up and make sure the batteries are inserted firmly Step 3 Place the cover on the battery compartment Push down until you hear the tab click into place Note Removing the meter batteries will not affect your stored result However you may need to reset your meter settings See pages 14 16 8 www sens com Use a soft cloth or tissue to wipe the meter exterior If necessary the soft cloth or tissue might be dipped in a small amount of alcohol Do not use organic solvents such as benzene or acetone or household and industrial cleaners that may cause irreparable damage to the meter Caution Donotexpose the meter to direct sunlight heat or excessive humidity for
25. t the test using a new bottle of control solution If results continue to fall outside the range printed on the test strip vial the TEE2 Test Strip and Meter may not be working properly Do not use your system and contact Spirit Healthcare 24 7 Freephone Support Line at 0800 881 5423 www spirit healthcare co uk 21 Using the Lancing Device You will need a lancing device in order to collect a blood sample You may use the lancing device contained in the TEE2 Blood Glucose Monitoring System or any other medically approved lancing device Adjustable Tip Lancet Holder Ejection System gt C3 RSEN Lancet Release Button Sliding Barrel Thelancing device should not be used by more than one individual Ensure the lancing device is not shared among different users Usea soft cloth or tissue to wipe the lancing device If necessary a small amount of alcohol on a soft cloth or tissue may be used Caution To avoid infection when drawing a sample use a lancet only one time and Do not use a lancet that has been used by others Always use a new sterile lancet Keep the lancing device clean Note Repeated puncturing at the same sample site may cause pain or skin calluses thick hard skin Choose a different site each time you test 22 www i sens com Preparing the Lancing Device Step 1 Wash hands and sample site with soap and warm water Rinse and dry thor
26. thorised i SENS sales representative e The unit of measurement is fixed and it cannot be changed by the user 12 www i sens com alarm mem appears when the appears when test time alarm has been results stored in set the memory are Test results displayed test results r Mute symbol displaying panel appears only when S mem chec Battery symbol indicates meter battery is running low and needs to be replaced the sound is set to E o Cow s appears when the x OI control solution test 5 c M are saved or t mmol L mg dL z Post meal test mark ipg Gg gg gg displayed appears during post m Blood insertion meal testing and Month Hour symbol when post meal test Day Minute indicates meter results are displayed is ready for the application of a drop mmol L of blood or control unit for measuring solution blood glucose Decimal point appears when the blood glucose measuring unit is set to mmol L Note It is recommended to check if the display screen on the meter matches the illustration above every time the meter turns on Do not use the meter if the display screen does not exactly match the illustration as the meter may show incorrect results www spirit healthcare co uk 13 Setting up Your System Press the M button while the meter is switched off Step 3 Setting the Month Press C button to reach the
27. ting period e Before a meal Before sleeping Situations requiring fingertip test When your glucose levels are unstable During the two 2 hours after a meal or exercise e When sick or when glucose levels seem quite lower than test value When hypoglycaemia is not well recognized When insulin has the biggest effect Two 2 hours after an insulin injection 30 www i sens com AST Precautions Donotignore the symptoms of hyperglycemia or hypoglycemia When the results of the test do not reflect your opinion retest using the fingertip test If the fingertip result still does not reflect the way you feel please consult your healthcare professional Donotrely on the AST results for changing your treatment method The amount of glucose in alternative sites differs from person to person Before using AST please consult your healthcare professional Note Results from alternative site and fingertip samples may differ from each other as there is a time lag for the glucose levels to reach the same value Use a fingertip for testing if you suffer from hypoglycaemia or have experienced hypoglycaemic shock or symptoms Note e If the sample drop of blood runs or spreads due to contact with hair or with a line in your palm do not use that sample Try puncturing again in a smoother area www spirit healthcare co uk 31 HI and Lo Messages Target Blood Glucose Ranges HI Message The meter displ
28. trip The blood or control solution sample was applied before the A symbol appeared Repeat the test with a new test strip and wait until the 4 symbol appears before applying the blood or control solution sample The temperature during the test was above or below the operating range Move to an area where the temperature is within the operating range 5 50 C 41 122 F and repeat the test after the meter and test strips have reached a temperature within the operating range www spirit healthcare co uk 39 General Troubleshooting Message What It Means What To Do The blood sample Repeat the test after has abnormally high inserting a new test viscosity or strip insufficient volume This error message Repeat test after may appear when inserting a TEE2 test the wrong blood strip glucose test strip is used instead of TEE2 blood glucose test strip There is a problem contact the Spirit with the meter Healthcare 24 7 Freephone Support Line at 0800 881 5423 or go to www spirit healthcare co uk Note e If the error messages persist contact the Spirit Healthcare 24 7 Freephone Support Line at 0800 881 5423 or go to www spirit healthcare co uk 40 www i sens com Problem Troubleshooting The display is blank even after inserting a test strip Check whether the test strip is inserted with the contact bars facing up Check if t

Download Pdf Manuals

image

Related Search

Related Contents

NEC Express5800/320Lb Setup and Configuration Guide  OPS-1000 Series User Manual  Une mise au point des options thérapeutiques pour les poux de la tête  Toxoplasmosis Gondii Real Time PCR Kit User Manual For  DYNAPAC CA 602 CONDUITE  Technoline WT 755  NGS White Slim Stand  Models 120, 280, 380, 480, & 480XT User`s Manual  Avtek International Video 280  Booklet Solarplexus neu.indd - solarplexus – sun will tell  